HomeMy WebLinkAboutSOLAR PANEL PAPERWORKPANELS SHALL NOT INSTALLED IN CORNER ZONES OF ROOF ASSEMBLIES. 0 yq PANEL w RIDGE RIDGE a .__�NQ. PANEL ROOF CORNER ZONE SHALL BE 10 PERCENT OF SHORT DIMENSION OF BUILDING OR 40_ PERCENT OF MEAN HEIGHT, OR 3 FT. WHICH EVER IS SMALLER. ROOF LAYOUT GENERAL C❑NDITI❑NS d_N w°Qa m PLUMBING sssmi¢ oiAr m anma O 1/2" O.S.B OR PLYWOOD_) ROOF DECKING STRAP BRACKET TILE ROOF upper hold down clamp see detail A or optional detail A-1 exB', 10' or 12' solar panels NOTE: EAGLE CLAW PLASTIC HEADER BRACKET ACCEPTABLE ALTERNATE x d (LJ STRAP BE A XET DETAIL C V CU £ PROVIDE �ry2 SCREWS W CONICAL ADEQUATE LENGTH TO CURE BRACKET TO CEMENT TILE DRILL HOLE THRU CONIC. TILE AND INSTALL SCREW SO AS NOT TO BREAK TILES. PANEL RISER SYSTEM RAFTER S-5 CLAMP S-5 CLAMP 7 3" PANEL 032 THICK 724 STANDING SEAM C❑NNECTI❑N rLL xNaxwWs srANMs DR rxv PLEASE NOTE: LOWER CLAMP/SPRING ASSEMBLY MAYBE OWNED PROVIDED A CONTINUOUS CROSS STRAP IS INSTALLED NO MORE IMAM 12* ABOVE LOWER/RETURN ASSEMBLY strop,VV"o —, STRAP SPACING 48" O.C. MAX `- LOWER/TI °� see hold down PANELS detail ENSURE TILE CAVITY IS FILLED COMPLETLY WITH DOW TILE BOND ROOF TILE ADHESIVE OR EQUAL APPLY ADHESIVE TO TILE AQUA THERM MOUNTING BRACKET IS ATTACHING TO PLUS ALL TILES AROUND IT (5) MINIMUM.& --ACCEPTABLE ALTERNATE. EXTEND THRU TO SHEATHING BELOW ADD SEALENT AT CONNECTION PROVIDE TAPCON SCREWS OF ADEQUATE LENGTH TO SECURE BRACKET TO CEMENT TILE. DRILL HOLE THRU CONC. TILE AND INSTALL TAPCON SO AS NOT TO BREAK TILES. 1/4" LAG ACCEPTABLE ALTERNATE OR #14 PHIL PAN OR HEX HEAD ACCEPTABLE ALTERNATE NOTE: THE MOUNTING BRACKET BY IRONRIDGE IS ACCEPTABLE FOR INSTALLATION OF THE PANELS PRVIDE 3/8"x 2 1/2" LAGS- 4FT & 6 FT O.C. MAX TO EXISTING TRUSSES BELOW 1. THE SOLAR COLLECTOR INSTALLATION AS DETAILED IN THE DRAWINGS IS FOR THE INSTALA71ON OF POTABLE WATER HEATING SYSTEMS ON STRUCTURES UP TO 35 FEET IN HEIGHT WITH ROOF SLOPES BETWEEN 0 AND 30 DEGREES, ROOF AREAS 1 AND 2 BUT NOT CORNERS. 2. THE DESIGN OF THIS INSTALLATION IS BASED ON ASCE7-10 FOR SURFACE AREAS BETWEEN 20 AND 48 SQUARE FEET RESULTING IN A MAXIMUM WIND PRESSURE OF <= 57 PSF. THE INSTALLATION SHALL UTILIZE ARD- WARE PROVIDED BY THE MANUFACTURER AS DETAILED IN THE INSTALATION MANUAL OR AS SHOWN ON PLAN. PLASTIC MOUNTING STRAPPING qwv- r 2-$14X 1 1/2 SEMI. AD OR HEX HEAD ASSFM01 111 UpvvR 0 FIHG � v etaI 0SSe�bl �, >m,G 'V � do n asse�,bl det0. lower tie PANG' 2-PA" VvEAD 2—$C HE)L/AEA; SORE W. UPPER CLAMP RAFTER �senb, 50D C`Qf it% lower tie dawn to 1ow� acceptoble oltemote ASSEMBLY MAY BE DELETED PROVIDED MOUNTING BRA PLASTIC BASE SET STRAPPING 1-y14x1 a" PAN HEAD OR HEX HEAD — MIN. 1/2- C. OR PLYWOOD SHEATHING ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIANCE REVIEWED BY Fj— DATE 9 NO PLANS AND PERMIT SEP 2 4 2019 ST. Lucie County, t I SCANNED BY St. Lucie County 14X 1 1/2-PAN HEA t HEX HEAD SCREW. — MR 1/2" G.S.G. OR PLYWOOD SHEATHING v V � RAFTER M❑UNTING BRACKET FLORIDA BUILDING CODE 2017, 6TH EDITION, TO INCLUDE THE EXISTING AND RESIDENTIAL CODES ULTIMATE DESIGN WAND SPEED: 180 NOMINAL DESIGN WIND SPEED: 140 RISK CATAGORY: 2 IMPORTANCE FACTOR: 1.0 EXPOSURE CATAGORY: C INTERNAL PRESSURE COEF: +-0.18. ENCLOSED STRUCTURE THE STRUCTURAL COMPONENTS OF THIS PLAN ARE IN COMPLIANCE WITH THE 2017 FLORIDA BUILDING CODE, WIND LOAD COMPLIANCE AND ITS RESISTANCE TO GRAVITY AND DESIGN PRESSURES E O U Y m 0 FT W L-) 6 3 P W} m N d QC) . L7 3 ! w> z le -j in KW 0JQ C W W Z P VI W:D Zr0 WWJY W 0LD� dLL U 90 Z = V) Z W L) L)v) ¢ Q . Q M Y= W W T, Q W0 ODD fU H" V Q,1- aw��Lr)xP, Z Y - InI7 DO coo) " L' 2zL? 0 H- W in (U U � � w Qto Ix V) 0- REVISION i DATE to _W to 0 Z W J WW �z ¢¢ �a OD: u- O (n 0 z Of 0 L) z ¢ DATE BY SHEET NUMBER S - 1