NOTICE OF ACCEPTANCE (NOA) C "amidade.eov/economv
J.A. Taylor -Roofing air "' SCANNED
302 Melton Drive ST. Lucie County, Permitting BY
Fort Pierce, FL. 34982 St. Lucie COunty
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used, in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami -Dade County) and or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Edge—Loc 1.0: x 16" wide x 24 ga. Steel Panel over Wood Deck
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA-No. 14-0418.01 and consists of pages 1 through 5.
The submitted documentation was reviewed by Freddy Semino a
NOA No.: 18-1023.17
MAW DADE000NTY Expiration Date: 01/09/2024
Approval Date: 12/20/2018
Page 1 of 5
ROOFING ASSEMBLY APPROVAL
Category
Sub -Category:
Materials:
_Deck Type:
Maximum Design Pressure
Roofing
Metal, Panels(Non-Structural)
Steel
Wood
—101.00 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product Dimensions
Edge-Loc 1.0 Length: various
Width: 16"
Height: I"
Thickness 0.024" (24 ga.)
Min. Yield Strength: 50 ksi
Trim Pieces Length: varies
Width: vanes
Thickness 0.024" (24 ga.)
Test Product
Specifications Description
TAS 110 Corrosion resistant, prefinished, coated
galvanized, galvalume, standing seam, metal
panels.
EVIDENCE SUBMITTED:
Test Agency Test Identifier
Valspar 433X515
Valspar 43313173
Force Engineering & Testing 72-0314T-06A-C
Inc.
Farabaugh Engineering and T158-07A
Testing Inc.
N/A Corrosion resistant, prefinished, coated
galvanized, galvalume, standing seam, metal
panels.
Test Name/Report
Date
ASTMB 117
11/21/11
ASTM D 4587, ASTM G 23
11/21/11
TAS 125
03/24/07
TAS 100 04/14/07
NOA No.: 18-1023.17
Expiration Date: O1/09/2024
Approval Date: 12/20/2018
Page 2 of 5
APPROVED ASSEMBLIES:
System:
Edge-Loc 1.0 Panel x 16" Wide x 24 ga. Steel
Deck Type:
Wood, Non -Insulated
Deck Description:
New Construction 19/32" or greater plywood or wood plank, or for re -roofing 15/32" or
greaterplywood.
Slope Range:
2": 12" or greater
Maximum Uplift
See Table A below
Pressure:
Deck Attachment:
In accordance with applicable Building Code, but in no case shall it be less than 8d ring
shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum
15/32") The above attachment method must be in addition to existing attachment.
Underlayment:
Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4"
side -lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps
and 12 gauge 1 ''/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered
rows 12" o.c. in the field of the roll. Or, any approved underlayment having a current NOA.
Fire Barrier Board:
Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation # 1.
Valleys:
Valley construction shall be in compliance with Roofing Application Standard RAS 133
and with PAC Contractors Association's current published installation instructions.
Metal Panels and
Install the "Edge-Loc 1.0 Panel" and accessories in compliance with the current published
Accessories:
installation instructions and details in PAC Contractors Association's Installation Manual.
Flashings, penetrations, valley construction and other details shall be constructed in
compliance with Roofing Application Standard RAS 133.
Panels shall be secured at a spacing listed below in Table A with corrosion resistant #10-13
x 1" pancake head screws of sufficient length to penetrate through the sheathing a minimum
3/1e of an inch.
The adjacent panel shall overlap and be secured to each other when The female rib of panel
is snapped over the male rib of panel.
TABLE A
MAXIMUM DESIGN PRESSURES
Roof Areas
Field
Perimeter and Cornerl
Maximum Design Pressures
—59.75 psf
—101.00 psf
Maximum Screw Spacing
16" o.c.
6.75" o.c.
1. Extrapolation shall not be allowed
NOA No.: 18-1023.17
MAMMADECOUNTY Expiration Date: 01/09/2024
up -TOM Approval Date: 12/20/2018
Page 3 of 5
SYSTEM LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and, corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i.e. perimeters, extended comers and corners).
3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in
Roofing Application Standard RAS 133.
4. All panels shall be permanently labeled with the manufacturer's name and/or logo, city, state, and the following
statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control
Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or
model.
C&MIADIMADE COUNTY
.•
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
6. Panels may be shop orjobsite roll formed with machine models Ws 5521095 and 7031100 from PAC Contractors
Association.
NOA No.: 18-1023.17
Expiration Date: O1/09/2024
Approval Date: 12/20/2018
Page 4 of 5
PROFILE DRAWINGS
18"
T,.z\--
Fastener Relief, Stiffening Ribs and Striations are Optional
Field Condition
EDGE-LOC 1.0 PANEL SYSTEM
END OF THIS ACCEPTANCE
NOA No.: 18-1023.17
Expiration Date: O1109/2024
Approval Date: 12120/2018
Page 5 of 5
REVIEWED FOR
MIMI®DARE CODE COMPLIANC
ST. LUCIE COUfi�tZVCTCONTROL SEc o
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (REISOC C 11805 SW 26 Sheet, Room 208
BOARD AND CODE ADMINISTRATION DIVISION V Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE(NOA) RECEIV ww .mlamidade.eov/economy
Sun-Tek Manufacturing, Inc.
10303 General Drive SEP 24 2019 - SCANNED
Orlando, FL 32824 BY
SCOPE: S7. Lucie County, Permitting St. Lucie County
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane
Zone of the Florida Building Code.
DESCRIPTION: ISFG Skylight System
APPROVAL DOCUMENT: Drawing No. STI-00000298, titled "ISFG", sheet 1 & 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated August 07, 2007, signed and sealed by James D. Wells, Jr., P.E., on October 06, 2017,
bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and the
expiration date by the Miami -Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
model/series and the following statement: "Miami -Dade County Product Control Approved", unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA #17-1023.22 and consists of this page 1, evidence submitted pages E-1, E-2, E-3 & E-4,
as well as approval document mentioned above.
The submitted documentation was reviewed by Hehny A. Makar, P.E., M.S.
/ ,�jJ NOA No. 10/31/2 23
MIAMFIn COUNTY {�(�/J Yam( Expiration Date: 10/31/2023
11 Jo l J 18 Approval Date: 11/0 2018
/ / Page 1
Sun-Tek Manufacturing, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMTTTED UNDER PREVIOUS APPROVAL #07-0425.04
A. DRAWINGS
1. Drawing No. STI-00000298-SH771SHT2, titled "ISFG", sheet I & 2 of 2, prepared
by Sun-Tek Manufacturing, Inc, dated 06104107 with last revision dated 08107107,
signed and sealed by James D. Wells, Jr., P.E.
B. TESTS (submitted under NOA # 02-0618.06)
1. Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per
PA 203 and Uniform Static Air Pressure Test per PA 202 of "Insulated Glass Skylight
with Polycarbonate Inner Liner" prepared by National Certified Testing
Laboratories, Report No. 210-2760-1, 2 & 3, dated 01122102, signed and sealed by B.
Portnoy, P.E.
C. CALCULATIONS
1. Anchor Calculations for attachment of skylight to curbing and curbing to decking,
dated 08113107, signed and sealed by James D. Wells, Jr., P.E.
D. MATERIAL CERTIFICATIONS (submitted under NOA # 02-0618.06)
1. Test report on Rate of Burning per ASTMD635 of Geon 87416 White 141
Exterior, 0.137 inch, prepared by Commercial Testing Company, Report No. 01-
11293, dated 11129101, signed by J. Jackson.
2. Test report on Selflgnition Temperature per ASTMD1929 of Geon 87416 White
141 Exterior, prepared by Commercial Testing Company, Report No. 01-11292,
dated 11129101, signed by J. Jackson.
E. STATEMENTS (submitted under NOA # 02-0618.06)
1. Code compliance letter issued by Product Technology Corporation. on 09127102,
signed and sealed by R J. Quiroga P.E.
F. OTHER
1. NOA renewal request letter issued by Sun-Tek Manufacturing, Inc., dated 08116107,
James Feudner.
2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL 911-0601.02
A. DRAWINGS
1. Drawing No. STI-00000298-SHTIISHT2, titled "ISFG", sheet 1 & 2 of 2, prepared
by Sun-Tek Manufacturing, Inc, dated August 07, 2007, last revision #A dated
October 14, 2011, signed and sealed by James D. Wells, Jr., P.E.
"W WL,4 --
elmy A. Makar, P.E., M.S.
Product Control Section Supervisor
NOA No.18-0716.03
Expiration Date: 10/31/2023
Approval Date: 11/01/2018
E-1
Sun-Tek Manufacturing, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
B. TESTS
1. Test Addendum for Test Report NCTL 210-2760-1, prepared by national Certified
- Testing Laboratories, dated October 17, 2011, certifying the interlayer thickness,
signed by Mark Bennett, Manager of Testing Services.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami -Dade County Department of Permitting, Environment, and Regulatory
Affairs (PERA).
E. MATERIAL CERTIFICATIONS
1. None.
3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #12-1011.15
A. DRAWINGS
1. Drawing No. STI-00000298, titled "ISFG", sheet 1 & 2 of 2, prepared by Sun-Tek
Manufacturing, Inc, dated August 07, 2007, last revision #A dated May 03, 2012,
signed and sealed by James D. Wells, Jr., P.E.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami -Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
F. OTHERS
1. A compliance letter, issued by J & L Wells Consulting LLC, dated 0412512012, certify
compliance with FBC 2010 edition, signed & sealed by James D. Wells, Jr., P.E.
2. Verification testing to be performed per letter from National Certified Testing
Laboratories, dated September 18, 2012, signed by Christopher Bennett.
"144L-411
Helmy A. Makar, P.E., M.S.
Product Control Section Supervisor
NOA No.18-0716.03
Expiration Date: 10/31/2023
Approval Date: 11/01/2018
E-2
Sun-Tek Manufacturing, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
4. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 13-1028.05
A. DRAWINGS
1. Drawing No. STI-00000298, titled "ISFG", sheet 1 & 2 of 2, prepared by Sun-Tek
Manufacturing, Tnc., dated August 07, 2007,-last revision #A dated August 15, 2013,-
signed and sealed by James D. Wells, Jr., P.E., on February 07, 2014.
B. TESTS
1. Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per
PA 203 and Uniform Static Air Pressure Test per PA 202 of "Insulated Glass Skylight
with Polycarbonate Inner Liner" prepared by National Certified Testing
Laboratories, Report No. 210-3915-01, dated 0812712013, signed and sealed by
Gerard Ferrara, P.E.
C. CALCULATIONS
1. Anchor Calculations for attachment of skylight Model ISFG to Decking, dated
1010312013, signed and sealed by James D. Wells, Jr., P.E.
D. QUALITY ASSURANCE
1. By Miami -Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. Bill of Material and Components Die Drawings.
5. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 15-0513.10
A. DRAWINGS
1. Drawing No. STI-00000298, titled "ISFG", sheet 1 & 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated August 07, 2007, last revision #A dated May 04, 2015,
signed and sealed by James D. Wells, Jr., P.E., on May 04, 2015.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami -Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
elmy A. Makar, P.E., M.S.
Product Control Section Supervisor
NOA No.18-0716.03
Expiration Date: 10/31/2023
Approval Date. 11/01/2018
E-3
Sun-Tek Manufacturing, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
6. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 17-1023.22
A. DRAWINGS
1. Drawing No. STI-00000298, titled "ISFG", sheet 1 & 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated August 07, 2007, signed and sealed by James D. Wells,
Jr., P.E., on October 06, 2018.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami -Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
7. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. None.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami -Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
F. OTHERS
1. A compliance letter, prepared by J & L Wells Consulting LLC, dated June 20, 2018,
certify compliance with FBC 2017 edition, signed & sealed by James D. Wells, Jr.,
P.E.
I-Relmy A. Makar, P.E., M.S.
Product Control Section Supervisor
NOA No.18-0716.03
Expiration Date: 10/31/2023
Approval Date: 11/01/2018
E-4
3TI-215 DECO COVER 0.0756063 T6 ALUM 17/32"GLASS BITE DWG. NO. STI.0000029&SH71
SILICONE BEDDING (CONTINUOUS) 719' OUTBOARD DES TEMPERED WRAP
DECOAROUND
RING MITERED AND
118"INBOARD GLASS DSB TEMPERED �VJRAP AROUND 0.0506063 T6 ALUM.
STI.6 GLASS GASKET EPOM
(CONTINUOUS) — INSULATED AIR SPACE STI-205 CMG FRAME 0.060 MITERED
ARGON GAS FILLED AND WELDED 6063 T6 ALUM.
STI-401 WOOD LINER 1d6X0.935'
(CONTINUOUS) S`MOGLESPACERry 1
1-32 PHILLIPS PAN HD SCREW AND HEX NUT
PER LONG SIDE 7 PER SHORT SIDE
SILICONE SEAL TOP AND BOTTOM 177 POLYCARBONATE SHEET
PALRAM PALSUN (CONTINUOUS)
IBUTYL 3 RINGS OF SEALANT
O a STI-300 PVC LINER STI.207 HSF SUB -FRAME MITERED AND
OBENEATH FLANGE (CONTINUOUS) GEON 67418 WHITE WELDED 0.0756063 T6 ALUM.
2 AROUND PERIMETER OF FLANGE
(CONTINUOUS) AND ON TOPOFEACH 147 EXTERIOR loDI ICIV1SED
z FLANGE SCREW Its corn lyi, ; with the Flnrido
M LL AIR SPACE OR iiaildil C O
�j DADE COUNTY APPROVED Ac` t ne O D.ZZ
e H SHINGLES EXPANDED POLYSTYRENE INSULATION d8 X!1" PHILLIPS PAN HEAD
I (SEE NOTE 1) ""pin",
"p- OR Ole 0 SCREW, (9) PER SIDE
L � e -- fluct Control \O\�SDpV D WF�s!/�
n
ROOF DECK mina -thick �� R�./�VG lRB'•.i✓,p/�
1*
rDESIGN PRESSURE RATING+- 80 PSF. — i
Engineer of Record 1. LARGE MISSILE IMPACT RESISTANCE •�6/�7Y
T %
James D. Wells, Jr.,P.E. i Q� A E OF
Professional Engineer No. 53616 NOTE:
•(1) ALL ROOFING DETAILS SHALL COMPLY WITH '���•.;<oR%
CHAPTER I5OFTHE FLORIDA BUILDING CODE 2017 ed184n �/ i •""••�� \\\
J&L Wells Consulting LLC (2) 4" MINIMUM DISTANCE FROM ANGLE LIPTO ROOF a
1453 Arbilus Circle
SURFACE IS FOR SHINGLE OR B.U.R. WITHOUT
'E �,. Op 1+xsr. III. 'lorida
Oviedo, Fl. 32785 INSULATION. FOR INSULATION AND TILE ROOF ADD Building C�dO
TILE HEIGHT AND INSULATION THICKNESS TO 4".
(407)495-5489 Accepranm Nn�— i6 • D$.
(3) ANCHORS TO BE MADE FROM Certificate of Authorization COMPATIBLE VVITHALUMINUMNON-CORROSIVE MATERIAL Gzpi Vion Date I OZ3
No. 27162 (4) NO ONE-THIRD INCREASE IN THE DESIGN PRESSURE WAS USED. RAFTER OR TRUSS
(5) TESTED TO TAB 201, TAB 202 AND TAB 203. By
t1i1 f0 4e1 (7{7]
M. BEnsioN PRODUCT NAME: ISFG SUN-TEK MANUFACTURING, INC.
M. MADE ONSNf ]OF2
B6o oAre usow7 6Y:. RAIE: BI157M13 DRAWN BY: JWF I DATE: 08115/201t DWG. NO. STI-D0000298-S HT7 I REV. A I 1D303 GENERAL DRIVE ORLANDO,FL32824
ME
DESIGN PRESSURE RATING+/- 00 PSF.
LARGE MISSILE IMPACT RESISTANCE
NOTE:
(1) ALL ROOFING DETAILS SHALL COMPLY WITH
CHAPTER 15 OF THE FLORIDA BUILDING CODE 2017 edflion
(2) 4° MINIMUM DISTANCE FROM ANGLE LIP TO ROOF
SURFACE IS FOR SHINGLE OR B.U.R. WTHOUT
INSULATION. FOR INSULATION AND TILE ROOF ADD
TILE HEIGHTAND INSULATION THICKNESS TO 4'.
(3) ANCHORS TO BE MADE FROM NON -CORROSIVE MATERIAL
COMPATIBLE WITH ALUMINUM.
(4) NO ONE-THIRD INCREASE IN THE DESIGN PRESSURE WAS USED.
(5) TESTED TO TAS 201, TAS 202 AND TAS 203,
STI-214 DECO RING MITEREDAND W
AROUND 0.050 W63'
SIUCONEBEDDING (CONTINUDM
ST14 GLASSGASKET EPOM
(OCNTINUOI/S)
STI-401 WOOD LINER --�
(CONTINUOUS)
118.32 Xi" PHILLIPS PAN HD SCREW
AND HEX NUT M PER SIDE
SILICONE SEAL TOP
AND BOTTOM (CONTINUOUS)
STI.2W HSF SUB -FRAME M17ERED
AMID WELDED CORNERS 0.075
O-n-, 6663 TBALUM
'0 3 RINGS OF BUTYL SEALANT
j w BENEATH FLANGE (CONTINUOUS)
10 AROUND PERIMETER OF n E
f u. (CONTINUOUS) AND ONTOP OF EACH
f FLANGE SCREW -
a y SHINGLES
+ (SEE NOTE 1)
98X VPHILPSP
SCREW (9) PER SIDE
i^min.plolrvsim
ROOF DECK 1l' min INdMess
RAFTER OR TRLSS --�
+I �_ 4" M LIP
I p ROOF
OOF SURFACE
O �
v ERglneer of Record uL
James D. Wells, Jr.,P.E. s
Professional Engineer No. 53616
J&L Wells Consulting LLC
1453 Arbitus Circle °
Oviedo, FI. 32765 ;
(407)496-5489 2
Certificate of Authorization
No. 27162 �
6p I MODEL
06
DWG. NO. STI-00000295-SHT2
- STI-216 DECOCWER 0.0756063 T6ALUM
/OUTBOARD DSBTEMPERED
j SIMGGLESPACER(0625'1
DSO TEMPERED
I])PoLYGgOf(UTE 91FEf
PNAN4 PAtsw
AIR SPACE OR
DADE COUNTY APPROVED
v�C 9Na�•.',
0,53616
�OR11)4'
HEAD "bbA-kkAmETOFRAME
S N832X3I4'WRHHEXNUT:
PER I PER I PER
SHORTSIOE I LONGSIDE I SHORTSIOE
I I I"" ISFG i SUN-TCK MANUFACTURING, INC.
°` .IVLe �OA1E' OVIVT3 IBY. I DRAWN BY: JWF DATE, io/14201 DWG. NO. STI-0000029BSHT2 REV. A 10303 GENERAL DRIVE ORLANDO. FL 32824