HomeMy WebLinkAboutPRODUCT APPROVALm�'Busrne°ss &PXassottal
3'.. , .co,":.,`, a �. ° s�` PnNa+E wtuFrIAM, oue oivlsl�.et4 ;cAM.ncrno'e'
g
r
Flo
Product Approval
USER: Public User
,.Vp0
Product Approval Menu > Pmduct or Apoliwtlon Search > Apliftation U9 > Appllotlon Derail
.:.. FL* FL1654-R24
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
A
SCANNED
BY
St. Lucie County
RECEIVED
SEP 2 4 2019
ST. Lucie County, Permitting
Product Manufacturer PWGLASS USA
Address/Phone/Emall 1111 W. Newport Center Drive REVIEWED FOR Deerfield Beach; FL 33442 CODE
C® �'1
(954)233-1330 Ext 242 OO..rr COMPLIANCE
malpert@polygiass.com STo LUCIE COUNTY
Authorized Signature Maury Alpert `7 EODD
malpert@polyglass.com
Technical Representative Maury Alpert
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
_(912) 429-8610
MAlpert@ polyg lass.cem
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method - Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
09/13/2021
ValidatedByJohn
W. Knezevich, PE
R Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL1654 R24 COI 2019 01 COI NIEMINEN.gdf
Standard
Year
ASTM D6162
2008
ASTM, D6163
2008
ASTM D6164
2011
ASTM D6222
2011
ASTM D6509
2009
FM 4470
2012
FM 4474
2011
UL 1897
2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
04/12/2019
Date Validated
04/14/2019
Date Pending FBC Approval
04/19/2019
Date Approved
06/18/2019
Date Revised
08/12/2019
Summary of Products
I
FL #
Modelr Number or Name
Description
1654.1
Polyglass SBS and APP Modified
SIBS and APP modified bitumen roof systems.
Bitumen Roof Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
PI 1654 R24 11 2019 04 FINAL Al ER POLYGLASS MODBIT FL1654-
R24.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
. Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this application
Evaluation Reports
relates to one particular assembly over concrete deck.
pl 1 Asa Red. AP 2019 04 FINAL ER POLYGLASS MODBIT FL1654
RR24.pdf
Refer to the ER Appendix for other systems and deck
types. 2.) Refer to ER, Section 5 for other Limits of
Created by Independent Third Party: Yes
Use.
Back Fe7
Contact Us :: 2601 Blair stone Road. Tallahassee K 32399 Phone: 850<87-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 state of Florida.:: Pdwcy statement :: Accscs ibility Statement :: 0.efuntl Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response m a publlcremrds request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any quesUans, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The malls
provided may be used for official communication with the licensee. However mall addresses are public record. V you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public To determine It you are a licenser under chapter 455, F.S., please click he- .
Product Approval fi=pis:
M ® ` imY E
{ Credit Gard
e-
NNEMOjetc.
APPENDIX 1:
, rTABLE 1
ATTACHMENT REQUIREMENTS FOR WIND
G
x : ea Tti ,,:. 1� F _ aun r> - a+•'
UPLIFT RESISTANCE
?'
w, .._7FAPPLICq�°ffON
to
Wood
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
5
IB -
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5-9
1C
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, BondedRoofCover
10-11
1D
Wood
New, Reroof (Tear -Oft) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
12
1E
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
12-14
1F
Wood
New, Reroof (Tear -Off) or Recover
D
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover -
15-18
SG
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover
18-22
1H
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover
23-28
11
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
29
2A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Banded Roof Cover
30-32
28
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
33-37
2C
Steel or Structural concrete
New', Reroof (Tear -Off) or Recover
D-1
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
38-39
2D
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D-2
Insulated, Mech. Attached Velociflex, Bonded Roof Cover
4D-41
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
42-50
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
50
4A
Lightweight concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
51-53
4B
Lightweight concrete
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
54
4C
,Lightweight concrete
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
55-58
SA
Cementitlous wood fiber
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
59
SB
Cementitlous wood fiber
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
60
Sc
Cementitlous wood fiber
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
61
SD
Cementitlous wood fiber
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
61
SE
Cementitlous wood fiber
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
61
6A
existing gypsum
Reroof(Tear-Off)
A-1
Bonded Insulation, Banded Roof Cover
52-64
6B
Existing gypsum
Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
64
6C
Existing gypsum
Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
64
6D
Existing gypsum
Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
64
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
65-69
7B
Various
Recover
F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
69
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be In accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBCApproval documentation.
2. Insulation/ base sheet fasteners shall be of sufficient length for the following deck engagement:
➢ Wood: Minimum 0.75-Inch penetration.
➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
➢ Structural concrete: Minimum 1-Inch embedment into pilot hole In accordance with fastener manufacturers published installation instructions.
NEMD ETC, LLC Evaluation Report P9290.02.08-R22 for FL1654-R24
Certificate of Authorization H32455 67" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 22: 04/11/2019
Prepared by: Robert Nleminen, PE-59166 . - Polyglass Modified Bitumen Roof Systems; (954) 233.1330 Appendix 1, Page 1 of 69
ONEMOletc.
3. Unless otherwise noted, insulation maybe anyone layer or combination of polylsocyanurate,polystyrene, wood fiberboard, perlite,gypsum-based roof board or mineral -wool roof board that meetsthe OArequirements
of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when Installed with the roof cover.
4. Minimum 200 psi, minimum 2-Inch thick lightweight insulating concrete maybe substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet
fasteners are Installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural
members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval
documentation.
S. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
B. Unless otherwise noted, Insulation adhesive application rates are as follows. Ribbon or bead width Is at the time of application; the ribbons/beads shall expand as noted In the manufacturer'spublished Instructions.
D Hot asphalt (HA):
Full coverage at 25-30 Ibs/square:
➢ Dow INSTA STIK Quik Set Insulation Adhesive (D-IS):
Continuous 0.75 to 1-inch wide ribbons, 12-Inch o.c.
➢ Millennium One Step Foamable Adhesive (M-OSFA):
Continuous 0.25 to 0.5-Inch wide ribbons, 12-Inch o.c.
➢Millennium PG-1 Pump Grade Adhesive(M-PGS):
Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
➢ OMG OlyBond 500 (OB500):
Continuous 0.75 to 1-Inch wide ribbons, 12-Inch o.c. (PaceCart or SpotShot). Note: OlyBond Green maybe used where OlyBond 5001s referenced.
D OlyBond Classic (OB Classic):
Full coverage at 1 gal/square.
D ICP Adhesive & Sealants Polyset CR-20:
Continuous 2.5-3.5-Inch wide ribbons, 12-Inch o.c.
➢Note: When multiple layers(s) of Insulation and/or coverboard are installed In ribbon -applied adhesive, board joints shall be staggered.
➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the Insulation board shall be not less than one-half the specified ribbons spacing.
7. Unless otherwlse noted, all Insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitation. In no case shall these values be used to'increase'the MOP listings In the tables; rather if MOP listing below meets or exceeds that listed for a particular system in the tables, then the
thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table:
➢ Millennium One Step Foamable Adhesive (M-OSFA):
MDP -157.5 psf (Min. 0.5-Inch thick)
D Millennium PG-1 Pump Grade Adhesive(M-PG3):
MDP -157.5 psf (Min. 0.5-inch thick)
D OMG OlyBond 500 (OBS00):
MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3)
D OMG OlyBond 500(OBSOo):
MDP -187.5 psf (Min. 0.5-inch thick)SO 95+GL) -
DOMGOlyBond 500(00500):
MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3)
D OMG OlyBond 500 (OB50o):
MDP -487.5 psf (Min. 0.5-Inch thick ACFoam II)
➢ ICP Adhesives & Sealants Polyset CR-20:
MDP -117.5 psf (Min.1.0-Inch thick)
8. Bonded polyisocyanurata Insulation boards shall be maximum 4 x 4 ft.
9. For mechanically attached components or partially bonded Insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined In accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDI, FM Loss Preventlon
Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RA5 137. Assemblies marked with an asterisk• carry the limitations set forth In Section 2.2.10.1 of FM Loss Prevention Data
Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis Is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. Aqualified design professional shall review the data for comparison to the minimum
requirements for the system. Testing and analysis shall be In accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates Ina bonded recover or re -roof Installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TA5124.
13. For Recover Applications using System Type D, the Insulation Is optional; however, the existing roof system shall be suitable for a recover application.
NEMD ETC, LLC Evaluation Report P9290.02.O13-1122 for FL1854-1124
Certificate of Authorization R32455 0 EDITION (2017) FBC NON-HVHZ EVALUATION Revision 22: 04/11/2019,
Prepared by: Robert Nleminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 2 of 69
OINEMOjetc.
14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat
thickness is 2-Inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For "pre-existent" LWC references, listings were established through testing over lightweight concrete cast
using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami -Dade BCCO (FBC CER1592). Unless otherwise noted,
use of these listings in new construction or re -roof (tear -off) applications is at the discretion of the Designer or Record and Authority Having Jurisdictlon.
15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
ROOF COVERS
REFERENCEz, „Y,�.,, .e
..,,;!LAYER ,,, e.^`
F ,a.,:....., . 2f , , C_ ?_.�.e ,v . - a ....`'.EuS `ti..-;: MATERIAI,,,,;:ui. a's ,.6..... a,b. �'r � . § :Iry S
,. AP2BCATto
BP -AA
Base Ply
One or more plies Polyglass G2 Base,FBC Approved ASTM D4601, Type II
(Base and Ply sheets,
Ply
One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI
Hot Asphalt at 2G-40
Asphalt-Applled)
Note:
Asphalt -applied sheets or Insulation shall not be applied to poly -film surfaced membranes.
Ibs/square
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 HP, Elastoshield HT
SBS-CAI
Cap Ply
Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 G, ElastoflexS6 G FR, Elastoshield TS G, Elastoshield TS
PG350 at 1.5-2.0
gal/square
G FR, Polyfresko G 5BS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 HP
SBS-CA2
Cap Ply
Elastoflex V G, Elastoflex V G FR, Elastoflex 56, Elastoflex S6 HP, Elastoflex 56 G, Elastoflex S6 G FR, Elastoshield TS G, Elastoshield TS
Polyplus 35 at 1.5-2.0
gal/square
G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply or Ply
One or more plies Elastobase (sand/sand or poly/sand), ElastobaseP (sand/sand or poly/sand), Elastoflex V, Elastoflex S6, Elastoflex
S6 HP, Elastoshield HT
SBS-AA
(SBS, Asphalt -Applied)
Cap Ply
Elastoflex V,'Elasmflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshleld TS G,
Hot Asphalt at 20-40
Ibs/square
Elastoshield TS G FR, Polyfresko GSBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Note:
Asphalt-applledsheets orinsuladon shall not be applied topoly)llm sur/acedmembranes.
Base Ply or Ply
One or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex S6, Elastoflex S6 HP, Elastoshleld HT
SBS-TA
(SBS, Torch -Applied)
Cap Ply
Elastoflex V, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex 56 G, Elastoflex S6 G FR, Elastoshield TS G,
Torch -Applied
Elastoshield TS G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed)
Base Ply
One or more plies Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V Plus, Elastoflex SA V Plus FR
SBS-SA
Cap Ply
Elastoflex SA P, Elastoflex SA P FR, Polyreflect
(SBS, Self -Adhering)
Note:
Unless otherwise noted, permissible membrane substratesforSBS-SA are limited to the SBS-SA Base Ply options herein,
Self -Adhering
Elastobase (Poly/sand) orflastobose (poly/poly).
APP-CA3
Cap Ply
Polyflex G FR
PG350 at 1.5-2.0
gal/square
APP-TA
Base Ply or Ply
One or more plies Polyglass Base, Polyflex, Polybond
(APP, Torch -Applied)
Cap Ply
Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR
Torch -Applied
Cap Ply
Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polykool
APP SA
(APP, Self -Adhering)
Note:
Unless otherwise noted,permissible membrane substratesforAPP-SA are limited to the SBS-SA Base Ply options herein,
Self -Adhering
Elastobase (poly/sand) or Elastobase (poly/poly).
NEMO ETC, LLC . Evaluation Report P9290.02.08-R22 for FL1654-RZ4
Certificate of Authorization #32455 bra EDITION 12017) FBC NON-HVHZ EVALUATION Revision 22: 04/11/2019
Prepared by: Robert Nleminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 3 of 69
NNEMOjetc.
16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MOP linings below vs. those In Table 3A
applies:
BARRIER OPTIONS;
DECK;VAPOR
STRUCTURAL CONCRETE
PRIMER
r INSULATION ADHESIVES `"ib""i v� r
a� TYPE
,. .
VB-1.
PG300
Elastoflex SA V Plus
Self -Adhering
Inta-Sttk or CR-20, 12-Inch o.c.
-60.0
VB-2.
PG300
Polyglass Base
Torch -applied
Inta-Stlk or CR-20, 12-Inch D.C.
-75.0
VB-3.
PG100
Elastoflex SAP
Self -Adhering
Insta-Stik, 12-inch o.c.
-75.0
VB-4.
PG100
Elastoflex SA P
Self -Adhering
Millennium One Step Foamable Adhesive, 12-Inch D.C.
-157.5
VB-S.
PGI00
Elastoflex SA P
Self -Adhering
CR-20, 12-Inch D.C.
-270.0
VB-6.
PG100
Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V
Plus, Elastoflex SA V Plus FR
Self -Adhering
I
Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade
I Adhesive, OlyBond 500 or CR-20, 12-Inch a.c.
-290.0
17. The following surfacing maybe applied to the Cap.Ply without adverse effect on the system wind load performance. Refer to current Florida Product Approval for approved Polyglass and KM Coatings roof coatings for
application limitations and a Roofing Materials Directory forfire ratings associated with coating usage.
OPTIONSSURFACING
rn -iD flon#., r
.' ;.,xA..v. vr., ` �'. `t k,'t r..f5urtddng �; a +m�- `$ e*". v.<,, •:
aF16r1da Piauct Appir
SURF-1.
PG300 Flbered Roof Coating
FL10291
SURF-2.
PG600 Non-Fibered Aluminum Roof Coating
FL10291
SURF-3.
PG650 Fibered Aluminum Roof Coating
FL10291
SURF-4.
PG700 High Quality Elastomeric Roof Coating
FL10291
SURF-S.
PG700QS (Quick Set) High Quality Elastomeric Roof Coating
FL10291
SURF-6.
PG800 Asphalt Emulsion Roof Coating
FL10291
SURF-7.
Polyplus 60 Premium Non-Fibered Aluminum Roof Coating
FL10291
SURF-8.
Polyplus 65 Premium Flbered Aluminum Roof Coating
FL10291
SURF-9.
Polybrite 70 Premium Grade Elastomeric Roof Coating
FL10291
SURF-10.
Polybrite 700S (Quick Set) Premium Grade Elastomeric Roof Coating
FL10291
SURF-11.
Polybrite 71 HS
FL10291
SURF-12.
Polybrite 90 High Solids Silicone Roof Coating
FL10291
SURF-13.
Polybrite 95 Silicone Roof Coating
FL10291
SURF-14.
KM Acryl 15
FL27409
SURF-15.
KM Acryl 15 OS
FL27409
SURF-16.
KM Acryl 25
FL27409
SURF-17.
KM Acryl 25 CIS
FL27409
SURF-18.
KM Acryl 40 HS
FL27409
SURF-19.
KM Acryl 85
FL27409
SURF-20.
KM PS#250
FL27409
SURF-21.
KM PS#220
FL27409
18. "MDP" = Maximum Design Pressure Is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
NEMO.ETC, LLC Evaluation Report P9290.02.08-R22 for FL16S4-R24
Certificate of Authorization #32455, 6- EDITION (2017) FBC NON-HVHZ EVALUATION Revision 22; 04/11/2019
Prepared by: Robert Nleminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 4 of 69
ONEMOletc.
TABLE IF: ....REROOF(TEAR-OFF)oR RECOVER
SYSTEM TYPED: INSULATED, MECHANICALLY ATTACHED : BONDED ROOF
System fnsulatlon layers) Base Sheet Roof Cover (Note 15) MDP
No.
Deck (Note 1)'
Type Attach
Type Fasten Attach
Base Ply Cap Ply (Psfl
AsP T-APPIIEDORTDRg APPIIEDBMEPLY: _
Elastobase,
Elastobase P,
Ones, more
Polyglass 62 Base,
OMG Flat Bottom Plates (square) with Roofgrip #14,
12-Inch o.c. at min.4-Inch lap and
(Optional) BP -AA,
W57
Min. 19/32-Inch
layers, any
Prelim.
CertaIGlasba Teede,
Dekfast Hex PLT-H-2-7lat with Dekfast
12-inch o.c. at two (2), equally
SBS-AA, SBS-TA or
SBS-AA, SBS-
-52.5
plywood
combination
Attached
Glasbase, Firestone
Firestone
"Dekfast
#14 or Trufast 3" Metal Insulation Plate with Trufast
Trufast
spaced, staggered center rows
APP-TA
7A pPP TA
TA
MB Base, lM Perma-
HD
Ply 28, Tamko Glass
Base or GAFGLAS #75
Min. 19/32-Inch
One or more
Prelim.
Elastobase or
12-Inch o.c. at min. 44nch lap and
(Optional) BP -AA,
SBS-AA, SBS-
W 58
plywood
layers, any
Attached
Elastobase P
OMG Flat Bottom Plates (square) with Roafgrip #12
12-Inch o.c. at two (2), equally
SBS-AA, SBS-TA or
TA, APP-TA
-60.0
combination
spaced, staggered center rows
APP-TA
APA rated, 19/32
Trufast Versa Fasteners (min. Y" penetration) &
SBS-SA, APP-
CAT, 0.578 in.,
One or more
Elastobase,
Plates; 2 screws per plate installed 180" into the
12-Inch o.c. at min. 4-inch lap and
SA, SBS-AA,
Exposure 1 OSB or
layers, any
Loose -laid
ElastabaseP
holes of the plate, parallel to the width -direction
12-inch o.c, at two (2), equally
5BS-TASBS-AA,
BS-TA, APP-TA
5B5-TA,APP-
-67.5
W-59
min. 19/32"APA
combination
spaced, staggered center rows
TA
rated plywood
of the sheet"
Note:
-For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 199lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized
to produce minimum withdrawal resistance
APA rated,19/32
Trufast Versa Fasteners (min. W penetration) &
CAT, 0.578 in.,
One or more
Plates; 2 screws per plate Installed 180" Into the
12-inch o.c. at min. 4-Inch lap and
Exposure 1 OSB or
layers, any
Loose -laid
Polyglass Base
holes of the plate, parallel to the width -direction
12-inch a.c. at two (2), equally
APP-TA
APP-TA
-67.5
W-60
min. 19/32" APA
combination
of the sheet
spaced, staggered center rows
rated plywood
Nate:
-For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 199 ibf. Additional Versa -Fast Fasteners within each Versa -Fast Pate maybe utilized
to produce minimum withdrawal resistance
One or more
Polyglass G2 Base,
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast
SO -inch o.c. at min. 4-inch lap and
(Optional) BP -AA,
6W-6�Min.
15/32-Inch
layers, any
Prelim.
Elastobase,
OMG Round Metal Plate with HD,
10-Inch o.c. at three (3), equally
SBS-AA, 5BS-7A or
SBS-AA, SBS-
-75.0
plywood
combination
Attached
Elastobase P
h Ro
OMG Flat Bottom Plate (Accutrac) with Raofgrip #14
OM o
spaced, staggered center rows
APP-fA
TA APP TA
or Trufast 3" Metal Insulation Plate with Trufast HD.
One or more
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast
104nch o.c. at min. 4-inch lap and
W-62
Min. 15/32-inch
layers, any
Prelim.
Polyglass Base
#14, OMG 3" Round Metal Plate with OMG HD,
10-Inch o.c. at three (3), equally
(Optional) APP-TA
APP-TA
-75.0
plywood
combination
Attached
OMG Flat Bottom Plate (Accutrac) with Roofgrip #14
spaced, staggered center rows
or7rufast 3" Metal Insulation Plate with Trufast HD.
NEMO ETC, LLC
Certificate of Authorization #32455
Prepared by: Robert Nieminen, PE-59166
6- EDITION (2017) FBC NON-HVHZ EVALUATION
Polyglass Modified Bitumen Roof Systems; (954) 233.1330
Evaluation Report P9290.02.08-R22 for FL1654-RZ4
Revision 22: 04/11/2019
Appendix 1, Page 15 of 69
I
s g ,
• r r 1 6 r + /
ME ki'm
15
eCIS Home I Log In I User Registration 1 Hot Topic,, I Submit Surtharge i Stats a Facts I Publications I HsC Stan I KIS Site Map 1 Unks i Searca
a
�� "� Product Approval
r -USER: Public User
db.
ProdV& Approval Menu > product or AoMkatfan Search > App,ratlon Ust > Ilpplieati n Detail
110 MIN FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Emall
Category
Subcategory
Compliance Method
SCANNED
BY
St. Lucie County
FL9777-RII
Revision
RECEIVED
2017
Approved
SEP 2 4 90?9
i
ST. Lucie County, Permitting
Owens Coming
One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscornlng.com
Greg Keeler
greg.keeler@owenscerning.com
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
Roofing
Undedayments
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
C:I Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License
PE-74021
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
12/31/2020
Validated By
Locke Bowden
Yi Validation Checklist - Hardcopy Received
Certificate of Independence FL9777 RII COI OCR14002 8a 2017 FBC Evaluation Report We therlock
Non-HVHZ.odf
Referenced Standard and Year (of Standard) Standard Year
ASTM D 1970 2015
ASTM D 226 2009
ASTM G 155 2005
TAB 103 1995
UL1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
10/11/2017
Date Validated
10/11/2017
Date Pending FBC Approval
10/17/2017
Date Approved
12/12/2017
Summary of Products
FL f0 Model, Number or Name
Description
9777.1 Wetherlock G
Weatherproofing Underlayment
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other. See evaluation report for limits of use,
Installation Instructions
FL9777 1111 11 OCR14002 ea 2017 FBC
Evaluation Reg4Lt
Weatherock Non•HVHZ.Ddf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
— —
FL9777 R11 AE OCR14002 8a 2017 FBC
Evaluation Report
Weathercock Non-e—
Created by Independentndent Third
hird Party: Yeses
9777.2 Weatherl-ock G (High Tear)
Limits of Use
Approvedforuse in HVHZ: No
f Approved for use outside HVHZ: Yes
j Impact Resistant: N/A
I Design Pressure: N/A
Other. See evaluation report for limits of use.
Weatherproofing Underlayment
Installation Instructions
FL9777 R11 II OCR14002 8a 2017 FBC
Evaluat'Qn Rg ors
Weathercock Non-HVHZ.odf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 RI AE OCR 14002 8a 2017 F8C
Eva; tign Rep,rt
Weath riock Nan-HVHZ Ddf
Created by Independent Third Party: Yes
y
9777.3
Weathercock MAT
Waterproofing Underlayment
Limits of Use
Approved for use in HVHZ: Yes
Installation Instructions
FL9777 Ri I If OCR 14002 8b 2017 FBC
h atio : Report
Approved for use outside HVHZ: No
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Weathercock HVHZ.Ddf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
1
FL9777 R11 AE OCR14002 8b 2017 FBC
F ah ation Report
Weathercock HVHZ bdf
Created by Independent Third Party: Yes.
.J
9777.4 Weatherlock MAT
Limits of Use
Waterproofing Underlayment
-Installation Instructions
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
1 Other: See evaluation report for limits of use.
FL9777 R11 II OCR14002 8a 2017 FBC
Eval Cation Report
Weathercock Non-HVHZ.Ddf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
i
FL9777 Ell AE OCRI4002 8a 2017 FBC
Evaluation Report
Wea[hedock Non-HVHZ odf
Created by Independent Third Party: Yes
9777.5
Weatherl-ock Metal
Weatherproofing.Undedayment
iLimits of Use
Approved for use In HVHZ: No
I Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other. See evaluation report for limits of use.
Installation Instructions
FL9777 R11 11 OCR14002 8a 2017 FBC
valuation Report
Weathercock Non-HVH .Ddf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 III AE OCR14002 8a 2017 FBC
Evaluation Report
Weatherlck Non-HVHZ Ddf
Created by Independent Third Party: Yes
9777.6
Weatherl-ock Metal
— —_._-...---
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
Impact Resistant: N/A
FL9777 RI1 11 OCR14002 eb 2017 FBC Evaluation
Report
Weatherock HVHZ Ddf
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Other: See evaluation report for limits of use.
Created by Independent Third Pally: Yes
Evaluation Reports
EL2777 RSi AE OCR 14007 86 017 PBC =vafi ration Report 1
I
Weath2diick HVHZ.pdf
Created by Independent Third Party: Yes
9777.7 WeatherLock Specialty Tile & Metal
Weatherproofing Underlayment
Limps of Use
t Installation Instructions
Approved for use in HVHZ: No
l ELg777 R1 i II O R1400 8a 2017 FBC Evaluation Report
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +0/hi42.5
Other: See evaluation report for limitsof use.
Weatherlock Non-HVHZ,pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
EL277Z Rll AE OCR14007 Ba 2017 FBC Evaluation Report I
Weatherlock Non-HVHZ.odf
Created by Independent. Third Party: Yes_
CICM we.t
tf. M&C I' :: 2601 still Stone Read. T.11.1happle FL 32399 phone: 850-487-1824
TM StMs Pt Floritla is an AAIEEO employer. LoovrlaM 300J-2p135tate of fiaida :: Pfivan Statement :: htmso,lb11Pv Statement : t Refurd Statement
Under Florida Iaw, small addresses are pudic records. if you do not want your email address released in response to a public-recards request, do poi send electronic
mall to this entity. Imtead, commit the oat' by Phone or by traditional mail. If you have any questions,please contact 850.487.1395. •Pursuant to Section
455.275(i), Santa statutes, effective OUAber1, 2012, limrsees, licensed under Chapter 455. F.S. must Pravda the Department with an Phial address if May have
one. The emels provided may be used for o0 del communication with the licensee. However mail addresses aye public remrd, If you W not wish m supply a personal
address, please Drowse the Oemmment wsh an email address which can be made available to the public To determine if you are a licensee under Chapter ass, F.S.,
. seceirit}+�tral`Rtca'
6 a ♦ r i a ai � .?-.
�'` s r•. .. . ,. -" :: h�( .� ,...ti s 6 2 Fy I -". is
` BC15 Home f Log 1n l User Reg$hadon I Hot Topks ! Submlt Surcharge 1 Stats 8 Fa¢s Publiwdons ! FBC Smif I Bcis Site Map 1 U,,ks Search i
areeR:puProduct Approval
us6tkuser SCANNED
BY
Product pnareva(Mrm»Raal ir[ruRaei pnni rnM cea�A.>poollratinn Ust>AOPnvtion eetail St. Lucie County
i '� FL# FL10674-R13 RECEIVED
Application Type Revision
Code Version 2017
Application Status Approved SEP 2 4 "V9
Comments ST. Lucie county, Permitting
Archived
Product Manufacturer Owens Coming
Address/Phone/Email One Owens Coming Parkway File Copy
Toledo, OH 43659.
(740)404-7829 ��gcso2—
FOR
greg.keeler@owenscoming.co
Authorized Signature Greg Keeler 0E COMPLIANCE
greg.keeler@owen n 11 p y,}+ ,x(ry� P'l�tli�Jp
Technical Representative Mel Sancrant STa E. UCIE COO n y ? /I
Address/Phone/Email 1 Owens COming_PKWY BOCC �% (
Toledo, OH 43659 /
(419)376.8360
mel.sancrant@owenscorniq.com
Quality Assurance Representative
AddressJPhone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
-s Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M. Nieminen
Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
05/16/2020
Validated By
John W. Knezevich, PE
:Oj validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL10674 R13 COI 2017 01 COI Nierrinen.odr
Standard
ASTM D3161
ASTM D3462
ASTM D7158
Year
2016
2010
2011
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
Summary of Products I
FL tk
Model, Number or Name
Description
10674.1
Owens Coming Asphalt Roofing
Shingles and Starters
3-tab, 4-tab, 5-tab, laminated, starter and hip & ridge shingles
Limits of Use
1 Approved for use In HVHZ: No
Installation Instructions
FL10674 R13 11 7017 SO EINAL ER OC ALPHA T
Approved for use Outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to ER, Section S.
SHINGLES FLI0674-R13 odf
Verified By: Robert l: M. Niernmen PE - 59166
Created by Independent Third Parry: Yes
Evaluation Reports
FL10674 R13 AE 2017 IQ FINA ER OC ASPHALT
SHINGLES. FL10674-R13
odf
Created by Independent Third Party: Yes
nF c :: ZOUlair Stone Road. T lln z 9 Mnne: 850-487ae24
The State of Flodda Is an grelEEO employer. Ceavdpht ]pp]- pt a Sm[ of FIo6d ;; privacy Statement :: AccessibiliN Statement :: p and hatam nt
Under aorlda law, email addresses are public rewNs. If you do not want your e-mall address released in response to a publlcremrds request, do not Send electronic
mail to this carry. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850. 87.1395. •Fursuant to section
455.275(l), Hands Statums, aBecsve October 1, 2012, licensees licensed under Chapter 455, F.S. must pmvlde the Department with an email address IF they have
one. The ¢maps pmulded may be used for official mmmunkadon with the licensee. However ¢mall addresses are public record. If you do not wish th supply a personal
address, please pmvlde Me Department war an email address which can be made available to the public To determine if you are a lueasee mMer Chapter 455, F.S.,
please dick b rear.
Product Approval Accepts:
® ®oml
sec urll\"}iL'1'EZIC.s.
f