HomeMy WebLinkAboutPORCH PLANS1 Design Pammetem 1. Building Occupancy Category, Paragraph 1604.5 and Table 1604.5: Risk Category I. 2. Basic Wind Speed, Table 1609C, State of Florida Debris Region 8 Basic Wind Speed, Paragraph 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed, VuLT =160 MPH 3. Exposure Category, Paragraph 1609.4.3 : C Applicable Codes. Regulation and Standards 1. The 6th Edition (2017) Florida Building Cade, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and Specifications for Aluminum Structure, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association, Inc. Washington, D.C., 2010 Edition 3. ASCE 7.10 General Notes 1. The contmctor shall verify all dimensions prior to construction 2. All work shall comply with all lowland regional ordinances. 3. Any deviation from this plan shall be reviewed by the engineer of record and is subject to approval. Specifications The following specifications are applicable to this pmjects : 1. Where concrete specification are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable. 1.1. Concrete shall conform to ASTM C94 for following components: 1.1.1. Portland Cement Type 1, -ASTM C 150 1.1.2. Aggregate - Large Aggregate 3/4' max-ASTM C 33 1.1.3. Air entraining +/-1%-ASTM C 260 1.1.4. Water reducing agent-ASTM C494 1.1.5. Clean Potable water 1.1.6. Other admixture not permitted 1.2- Metal accessories shall conform to: 1.2.1. Reinforcing Bars - ASTM A615, grade 60 1.2.2. Welded wire fabric-ASTM A185 1.3. Concrete slump at discharge per chute not less then W or more than 5". Water added after batching is not permitted. 1.4. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2 and 3 including hot weather recommendation: 1.5. Moist cure or polyethylene wring required. 1.6. Prior to placing concrete, beat the entire subsurface area for termites in compliance with the FBC. 1.7. All aluminum components embedded within concrete shall be coated with E bituminous paint or epoxy. I.B. Fiber reinforced concrete per ASTSM C1116 is an acceptable alternative to 6X6 W1.4/W1.4 W WF. 2. Aluminum extrusions shall be 6005 T5 Alloy, 3. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plate to ASTM B633, or stainless steel series "300". 4. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from end 24" on center or #12 screws 6" from end 12" on center. 5. Screened enclosures containing swimming pools shall comply with the applicable requirements of FBC R4501.17 Residential Swimming Barrier requirements. 6. Door location shall be determined by contractor in the field. 7. When installing pavers over concrete slab or footing which are supporting aluminum members, such as continuous screen tracks or upright, the anchors must extend past the pavers and reach proper embedment into the underlying foundation. 8. All gashing and waterproofing shag be provided by the contractor. 9. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. 10. Vinyl and acrylic panels shall be removed when wind speeds exceed 75mph Foundation Design: New B"Xil" (1 OS bar Cont.) thickened edge, 4" monolithic slab Concrete shall be a minimum 2,500 psi FIBERCRETE. Rebar3l" lap splice. Use 3" chairs. Per curent edition of the Florida Building Code, Residential, Section 401.4.1, soils testing is not required for design using the presumptive bearing pressure of 1.500 psf. Roof Type Screen Size Composite 18114 HOLLOW STCTION9 SELF MATNO BEAM 5MB1 THE POgCH FACTORY BEAM 2x2OWS O,JON 2x4SM0: T,4•x B.0Wx0.10P 3,IS PFB: Sx].Tfi'x0.B5G• 2x1 r.r OAST 2x5SMS, Tx Sx SO6rx0,107 5]S PFB: 2x5.rSa0l5S 2M 4: r 4. 0,0W 2x8SM0: 'Ix8'x 0.O5P x0.12P COLUMNS 2x 5: 2x5 Musr 2x75MB: VXrxD05r•x0.1M 2x.1: YxTx0.m. OPEN BACK SEGTpNS 2xesMa 2'xa•v 0.0rSxo.txC 4x4: Td•z 0.125• 2x BSM0: 2[rxDWTx0.12L' 6x8: 5b6•x0,12S x Tv0A45• MMWUN FASTENER EDGE DISTANCE: 1W CONCRETESCREWMCHOR: SHEETMAWLSCREws(SMS): SLWSONTnENLIDOREDUrvA W rWBUILOMOREGUNALENT NOTE: THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES. DRAWING NOT TO SCALE. USE DIMENSIONS GIVEN. CABLE BRACING MAY TERMINATE AT SLAB IN DIFFERENT LOCATION. MAINTAIN ANGLE PER DETAIL 1 1 4 . . .4 . •..' 4 HNw- 4 ' 1 < i w • 4, w . �•' ^.I� IY Tl09H w � 4 0 rms 1. CONOSIE c. xe SLWL ff OiSfAVD) ONLY OX r41iILIm, OIBL OR5W0 m M .". XS IRA CIPRNr FDlllp! Oi 112 f101✓0L BLaDOa COOF MEW SFL'IFJN W1.A1. t41.. 16Tpp leM D[ DPP E0.T Ma AOEgWL1 C0160rA5�lrp TO RO /�IL1VNES N SuxX =2 Me Z,,Z Ra1fUCfl0n. AR SMR S ROS A St' W MM uSE Y cNVS TD Mg?AH T gEARyIS m0M THE SOS, THICKENED EDGE SLAB ON GRADE ` i ,HOST 0.024-ALUM. SXW 1-1-S US AM CORE PANELS. fti=.1) 1 71 REVIEWED FOR CODE COMPLIANCE ST. LUCIE�aC/'OUNTY BOCC Vile Copy SCANNED BY St. Lucie County v C m a m lY mCO W C rai 0 N W It LL = O L 0yLoa co ` O n7 IL a' m �O ti SHEET 1 L ;)r NEOPRENE WASHER ON EACH LAG 3-X 0.082 ALV ' RECEIVING CHANNEL W/ ' 012 X 3M' TOP AND BOTTOM AS END CAP (2) WB' DIA THRU BOLTS IF SCREEN WALL BENEATH COMPOSITE ROOF, 1' x T MD (2) 010 x2-SMS INTO SCREWBOSSES INTO UPRIGHT & (1) 014 X 2' SMS B' FROM EACH SIDE OF UPRIGHT & ®24' O.C. NOTCH UPRIGHT OR POST TO ACCEPT BEAM. SEE PLANSHEETFORMEMSER INFORMATION 129¢ II8'ANGLEEA SIDE (1) 3I8' DI SCREWAI CR-O COMPOSITE ROOF TO BEAM 2 SCALE: NTS SIDE VIEW — (1) IM' OR THRU BOLT WITH NYLCCK JAM NUT NAM NUT WITH THREADLOCKER MAY BE USED, IN UEU). DO NOT OVERTIGHTEN. TIGHTEN ONLY UNTIL CONTACT. FOR 2X2 AND 2X3 UPRIGHTS, USE (4) 014 x W4-SMS INTO POST — BRICK PAVERS. MAY NOT BE PRESENT. ENSURE MIMMUMCONCRETE EMBEDMENT. zo .,w TOP VIEW AT INTERMEDIATE FOUNDATION PER PLAN PERPLAN Q O.B. ANCHORED TO CONCRETE 4Ti DIA.CONCRETE SCREW NCHOROft ®24' O.C. MA% (4) 014 x We SW INTO POST FORCORNER CONNECTION FASTEN 1X2 WITH 012 x W4- SMS®2'O.C. FLASHING -INSTALL UNDER EXISTING DRIP - EDGE 414 X 34' SMS ® W O.C. TOP AND BOTTOM WI 1-1R' DU. NEOPRENE WASHER O TOP SCREW ONLY 1 Q.. ROOF PANEL i'X I-X 1/8'ALUM ANGLE WI (3) 012 X We SMS IN FLANGE INTO UPRIGHT. (BOTH SIDES OF UPRIGHT) BEAM. SEE PLAN SHEET FOR MEMBER INFORMATION 0 ?01IX2I ® 1[�F- UPRIGHT (4)014x 2'ISMS THRU In - INTO POST TOP VIEW AT CORNER B-1 UPRIGHT TO FOUNDATION CONNECTION 2 SCALE:NTS (2)114- DIA. X W LAD SCREWS COMPOSITE CR-1 COMPOSITE ROOF TO HOST 2 SCALE:NTS WITH (41014 x TV SMS INTO POST v118'x2'x2-ANGLE RICK PAVERS MAY NOT BE PRESENT. FOLLOW .ANCHORMINIMUM CONCRETEEMSEOMENT z� e ♦ e <� ?w . e r SIDE VIEW PER PLAN i4 O.B.ANCHOREDTO CONCRETE WITH 1/4' DIA. ANCHOR (MIN. 1-114- EMBED) ® 24' O.C. 014 x 31 • SMS INTO 1)W8-DIA CONC. E •tNCHOR. EMBED MIN. -IW 6-V ... e W e OOTNG.SEEPLANFOR FRONT VIEW DETAILS 1 DOORJAMB CONNECTION ft SCALE:NTS SHIM AS NECESSARY IF OTHER THAN A PLUMB CUT FASCIA (2) IM-x3-LAGSCREWS,B' FROM ENO & @ IV O.C. CONC. (2) U4' DIA.x2 iW CONCRETE SCREW ANCHOR, S' FROM END & 0 IV O.C. OPTION 1:- (4)310x1-lp SMSINTO SCREW BOSSES (TYP) SELF2 TNG BEAM ONLY ENDS & 1T O.C. CONC. 114- DIA x Y CONCRETE SCREW ANCHOR ®S'FROM ENDS& 24'O.C. 2-x Tx IV ANGLE WITH (2) 910 x We SMS IN EACH FLANGE, EACH SIDE(TYP) �PURUNI GIRT! CHAIR RAIL _ M-1 PURLIN / GIRT / O.B TO HOST CONNECTION 2 SCALE: NTS FRONT VIEW B-4_ SUBPOST CONNECTION 2 SCALE:NTS 2-X T X ire' X 2'ANGLE WITH (4) 012 X 31 ' SMS EACH FLANGE In OPEN BACK ANCHORED TO CONCRETE WITH IW DIA. CONCRETE ANCHORS ® V FROM ENDS AND 24. O.C.. 1-114- MIN. CONCRETE EMSEDMENT.IF PAVERS ARE PRESENT, DRILL THROUGHTOGETMIN EMBEDMENT INTO FOUNDATON. CHAIR RAIL 00 om0 0 m y BASE SIDE VIEW 9 d O Aa a O d rai c o Lv u_ N d i ABM V tom L d L) O ` U)MW)a a U)CO i 9 U. Q L v i d �O a SHEET 2