HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: CLARK RESIDENCE
Builder Name:
SCANNED
Street: PULITZER ROAD
Permit Office: ST LUCIE COUNTY
BY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
St. Lucie COUrIt i/
Jurisdiction: ST LUCIE COUNTY
Owner:
County: St. Lucie (Florida Climate Zone 2 )
-Design Location: FL, Fort Pierce
1. New construction or ebsbng New (From Plans)
9. Wall Types (2000.0 sqft.)
a. Concrete Block - Erd Insul, EMerior
Insulation Area
R=4.1 2000.00 112
2. Single family or multiple family Single-family
b. N/A
R= ft
3. Number of units, if multiple family 1
c. N/A
R= ft,
3
d. N/A
R= ft2
4. Number of Bedrooms
10. Ceiling Types (2419.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 2419.00 112
6. Conditioned floor area above grade (ft2) 2419
b. N/A
R f 2
R=
c. NIA
Conditioned floor area below grade (112) 0
11. Ducts
R ft2
7. Windows(318.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor. Sgl, U=0.32 230.00 ft2
SHGC: SHGC=0.22
12. Cooling systems
kBtu/hr Efficiency
b. U-Factor: Sgl, U=0.65 88.00 ft2
a. Central Unit
42.0 SEER:16.00
SHGC: SHGC=0.30
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtulhr Efficiency
d. U-Factor. N/A ft2
a. Electric Strip Heal
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 6.780 ft.
14. Hot water systems
Area Weighted Average SHGC: 0.242
a. Electric
Cap: 50 gallons
8. Floor Types (2419.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 2419.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Total Proposed Modified Loads: 74.93
PASS
Glass/FloorArea: 0.131 Total Baseline
Loads: 78.24
I hereby certify that the plans and specifications covered by
Review of the plans and
O�TgE'SpgTA
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates Compliance
with the Florida Energy Code.
PREP D BY:
Before construction is Completed
04 y
DATE:
this building will be inspected for
compliance with Section 553.908
q P
r
I hereby certify that this uilding, as designed, is in mpliance
Florida Statutes.
G QD�
with the Florida Energy ode.
OWNER/AGENT
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
10/28/2019 12:09 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6
M
RY CHECKLIST REPORT
FORM R405-2017 INPUT SUMMA
PROJECT,
Title:
CLARK RESIDENCE
Bedrooms:
3
Address Type:
Street Address
'
Building Type:
User
Conditioned Area: 2419
Lot#
Owner Name:
Total Stories:
1
Block/Subdivision:
of Units:
1
Worst Case:
No
PlatBo#
Street: :
PULIucie ROAD
Builder Name:
Rotate Angle:
0
No
Count:
County.
St. Lucie
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
City, State,
Zip:
FORT PIERCE,
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
FL,
Family Type:
Single-family
New/Epsting:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design
Temp
Heating
Design Daily Temp
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2419
24190
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1
LAUNDRY RM
214
2140
No
0
1
Yes
Yes
Yes
2
PANTRY
60
600
No
0
1
No
Yes
Yes
3
KITCHEN
304
3040
Yes
0
1
Yes
Yes
Yes
4
DINING ROOM
247
2470
No
0
1
Yes
Yes
Yes
5
HALL
30
300
No
0
1
No
Yes
Yes
6
M WIC
77
770
No
0
1
Yes
Yes
Yes
7
MASTER BEDROO
253
2530
No
0
1
1
Yes
Yes
Yes
8
DEN
99
990
No
0
1
No
Yes
Yes
9
M BATH
143
1430
No
0
1
Yes
Yes
Yes
10
FOYER
132
1320
No
0
1
Yes
Yes
Yes
11
BATH 2
32
320
No
0
1
No
Yes
Yes
12
HALLWAY
59
590
No
0
1
No
Yes
Yes
13
CLST 3
20
200
No
0
1
Yes
Yes
Yes
14
BEDROOM 3
176
1760
No
0
1
1
Yes
Yes
Yes
15
BATH 3
48
480
No
0
1
Yes
Yes
Yes
16
SINKS 3
64
640
No
0
1
Yes
Yes
Yes
17
BEDROOM 2
177
1770
No
0
1
1
Yes
Yes
Yes
18
CLST 2
18
180
No
0
1
No
Yes
Yes
19
LIVING ROOM
266
2660
No
0
1
Yes
Yes
Yes
10/2812019 12:09 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6111 Edition (2017) Compliant Software Page 2 of 6
ov nUpflvl 1¢T DCDnPT
FORM K4Ub-ZUl/
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
_
1 Slab -On -Grade Edge Insulation
LAUNDRY RM
35 ft
0
214 ft'
--
1
0
0
_
2 Slab -On -Grade Edge Insulation
PANTRY
1 it
0
60 112
--
1
0
0
3 Slab -On -Grade Edge Insulation
KITCHEN
16 It
0
304 ft
--
1
0
0
4 Slab -On -Grade Edge Insulation
DINING ROOM
13 It
0
247 ft2
--
1
0
0
_
5Slab-On-Grade Edge insulation-
HALL
1ft
0
30 112
--
1
0
0
_
6 Slab -On -Grade Edge Insulation
M WIC
7 It
0
77 112
--
1
0
0
_
7SIab-On-Grade Edge Insulation
MASTER BEDRO
30 ft
0
253 112
--
1
0
0
_
8 Slab -On -Grade Edge Insulation
DEN
1 it
0
99 ft2
--
1
0
0
_
9 Slab -On -Grade Edge Insulation
M BATH
lift
0
143112
--
1
0
0
_
10SIab-On-Grade Edge Insulation
FOYER
6 It
0
132 ft2
--
1
0
0
_
11Slab-On-Grade Edge Insulation
BATH 2
1 It
0
32 112
--
1
0
0
_
12SIab-On-Grade Edge Insulation
HALLWAY
1 It
0
59 11
=—
1
0
0
_
13SIab-On-Grade Edge Insulation
CLST 3
2 ft
0
20112
-__
1
0
0
_
14SIab-On-Grade Edge Insulation
BEDROOM 3
12 It
0
176 112
--
1
0
0
_
15SIab-On-Grade Edge Insulation
BATH 3
14 It
0
48 ft2
-__
1
0
0
_
16SIab-On-Grade Edge Insulation
SINKS 3
8 ft
0
64 ft2
--
1
0
0
_
17Slab-On-Grade Edge Insulation
BEDROOM 2
13 ft
0
177 ft2
--
1
0
0
_
18SIab-On-Grade Edge Insulation
CLST 2
1 It
0
18 112
--
1
0
0
19SIab-On-Grade Edge Insulation
LIVING ROOM
33 It
0
266 ft2
--
1
0
0
ROOF,
Roof
Gable
Roof
Red
Solar SA Emift
Emitt
Deck
Pitch
# Type Materials Area
Area
Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip Flat tilelslate 2705 ft2
0 ft2
Medium
N
0.6 No 0.9
No
20
26.6
ATTIC
J#
Type
Ventilation
Vent Ratio (1 in)
Area
FIBS IRCC
1 Full attic
Unvented
0
2419 ft2
N N
10/28/2019 12:09 PM EnergyGaugeal USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Sofhvare Page 3 of 6
MY CHECKLIST REPORT
FORM R405-2017 INPUT SUMIVIA
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frec Truss Type
1
Under Attic(Unvented) LAUNDRY RM
0
Blown
214 ft2
0.1
Wood
_
2
Under Attic(Umrented) PANTRY
0
Blown
60 ft2
0.1
Wood
_
3
Under Attic(Unvented) KITCHEN
0
Blown
304 ft'
0.1
Wood
_
4
Under Attic(Umuenled) DINING ROOM
0
Blown
247 ft2
0.1
Wood
_
5
Under Attic(Unwnted) HALL
0
Blown
30 fP
0.1
Wood
_
6
Under Attic(Unvenled) MWIC
0
Blown
77ft2
.1
Wood
_
7
Under Attic (Unvented) MASTER BEDRO 0
Blown
253-ft2
0.1.
Wood
_
8
Under Attic(Unwnted) DEN
0
Blown
99 ft2
0.1
Wood
_
9
Under Attic (Unvenled) M BATH
0
Blown
143 ft2
0.1
Wood
_
10
Under Attic(Unvented) FOYER
0
Blown
132 ft2
0.1
Wood
_
11
Under Attic (Unvented) BATH 2
0
Blown
32 ft2
0.1
Wood
_
12
Under Attic(Unvented) HALLWAY
0
Blown
59 ft2
0.1
Wood
_
13
Under Attic (Unvented) CLST 3
0
Blown
20 112
0.1
Wood
_
14
Under Attic (Unvented) BEDROOM 3
0
Blown
176 ft2
0.1
Wood
_
15
Under Attic (Unvented) BATH 3
0
Blown
48 112
0.1
Wood
_
16
Under Attic(Unvented) SINKS
0
Blown
64 ft2
0.1
Wood
_
17
Under Attic (Unvented) BEDROOM 2
0
Blown
177 ft2
0.1
Wood
_
18
Under Attic(Unvented) CLST2
0
Blown
18 ft2
0.1
Wood
_
19
Under Attic (Unvenled) LIVING ROOM
0
Blown
266 ft2
0.1
Wood
WALLS
Cavity
Width
Ht
Framing
Solar
Below
Adjacent Space
Et_eigh1.t
A'aSheathing
1
N
Exterior Concrete Block - Ext InsdIAUNDRY R
4.1
19
0 10
0
190.0 ft2
0
0
0.6
0
_
2
E
Exterior Concrete Block - Ext InstUAUNDRY R
4.1
16
0 10
0
160.0 ft2
0
0
0.6
0
_
3
E
Exterior Concrete Block- Ext Insul KITCHEN
4.1
16
0 10
0
160.0 ft2
0
0
0.6
0
_
4
E
Exterior Concrete Block - Ext InsiJINING ROO
4.1
13
0 10
0
130.0 ft2
0
0
0.6
0
_
5
N
Exterior Concrete Block - Ext Insul M WIC
4.1
7
0 10
0
70.0 ft2
0
0
0.6
0
_
6
N
Exterior Concrete Block - Ext InsMASTER BE
4.1
15
0 10
0
150.0 ft2
0
0
0.6
0
_
7
W
Exterior Concrete Block - Ext InsLMASTER BE
4.1
15
0 10
0
150.0 ft2
0
0
0.6
0
_
8
W
Exterior Concrete Block - Ext Insul M BATH
4.1
11
0 10
0
110.0 ft2
0
0
0.6
0
_
9
W
Exterior Concrete Block - Ext Insul FOYER
4.1
6
0 10
0
60.0 ft2
0
0
0.6
0
_
10
S
Exterior Concrete Block - Ext Insul CLST 3
4.1
2
0 10
0
20.0 ft2
0
0
0.6
0
_
11
S
Exterior Concrete Block - Ext InstSEDR00M 3
4.1
12
0 10
0
120.0 ft2
0
0
0.6
0
_
12
S
Exterior Concrete Block - Ext Insul BATH 3
4.1
8
0 10
0
80.0 ft2
0
0
0.6
0
_
13
W
Exterior Concrete Block - Ext Insul BATH 3
4.1
6
0 10
0
60.0 fP
0
0
0.6
0
_
14
W
Exterior Concrete Block - Ext Insul SINKS 3
4.1
8
0 10
0
80.0 ft2
0
0
0.6
0
_
15
W
Exterior Concrete Block - Ext InstBEDROOM 2
4.1
13
0 10
0
130.0 ft2
0
0
0.6
0
_
16
E
Exterior Concrete Block - Ext InsdIIVING ROO
4.1
14
0 10
0
140.0 ft2
0
0
0.6
0
_
17
S
Exterior Concrete Block - Ext InSdIIVING ROO
4.1
19
0 10
0
190.0 ft2
0
0
0.6
0
10/28/201912:09 PM EnergyGauge® USA 6.0.02 (Rev, 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 6
....,.. i.u�n ur rc"r oconGT
FORM R405-2017
INru I JUIVIIYIAR r vnwr.�2v 2
DOORS
#
Omt
Door Type
Space
Storms
U-Value Width
Ft In
Height
Ft In
Area
1
E
Insulated
LAUNDRY R None
.4
3
6 8
20 ft
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
/
V #
Omt ID Frame
Panes
NFRC
U-Factor SHGC Imp
Area
Depth Separation
Int Shade
Screening
1
N 1 Vinyl
Low-E Single
Yes
0.32 0.22 N
9.0 T
2 It 0 in
1 ft 4 in
None
None
_
2
E 2 Vinyl
Low-E Single
Yes
0.32 0.22 N
15.0 ft2
12 ft 0 in
1 ft 4 in
None
None
_
3
E 3 Vinyl
Low-E Single
Yes
0.32 0.22 N
9.0 ft2
12 ft 0 in
1 ft 4 in
None
None
_
4
E 3 Metal
Low-E Single
Yes
0.65 0.3 N
48.0 ft2
12 ft 0 in
1 It 4 in
None
None
_
5
E 4 Vinyl
Low-E Single
Yes
0.32 0.22 N
40.0 ft-
12 ft 0 in
1 ft 4 in
None
None
_
6
W 7 Vinyl
Low-E Single
Yes
0.32 0.22 N
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
_
7
W 8 Vinyl
Low-E Single
Yes
0.32 0.22 N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
_
8
W 9 Metal
Low-E Single
Yes
0.65 0.3 N
24.0 ft2
2 ft 0 in
1 ft 4 in
None
None
_
9
S 11 Vinyl
Low-E Single
Yes
0.32 0.22 N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
_
10
W 13 Vinyl
Low-E Single
Yes
0.32 0.22 N
12.0 fF
2 ft 0 in
1 ft 4 in
None
None
_
11
W 15 Vinyl
Low-E Single
Yes
0.32 0.22 N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
_
12
E 16 Vinyl
Low-E Single
Yes
0.32 0.22 N
40.0 fl2
12 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
_
13
S 17 Vinyl
Lax-E Single
Yes
0.32 0.22 N
30.0 ft2
2 ft 0, in
1 ft 4 in
Drapes/blinds
Exterior 5
_
14
W 9 Metal
Lax-E Single
' Yes
0.65 0.3 N
16.0 ft2
2 ft 0 in
1 It 4 in
None
None
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50)
.000445
2822.2 154.93 291.37
.1685
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
C0P:1
27 kBlu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
SEER: 16
42 kBtu/hr 1260 din
0.8 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1
Electric
None
LAUNDRY RM 0.98 50 gal 62.3 gal
120 deg
None
10/28/201912:09 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
MARY CHECKLIST REPORT
FORM R405-2017
INPUT SUM
SOLAR HOT WATER SYSTEM
Collector Storage
FSEC
Cert # Company Name
System Model # Collector Model # Area Volume
FEF
ft,None
None
DUCTS
—Supply--
—Return--
Air
CFM 25
CFM25
OUT ON
RLF
HVAC#
Heat Cool
# Location R-Value
Area Location Area
Leakage Type
Handler
TOT
1 Attic
6
175 ft' Attic 18 ft'
-Default Leakage
Attic
(Default).c(Default) c.
1 1
_
TEMPERATURES
Programable[ling[XT]]hermostatr: N
Fans:
CrMay
F:br[X']
Mar]Apr]
[oiling
I
[X]
ri Jun Jul
r
rl Aug
[ ]
rl Sep
]
L 1 Oct
Nov
trX,]Dec
ec
[ ]Dec
Venting
Mar Apr
[ May
E)
Jun 1 Jul
I Aug
[ 1 Sep
lXl
[ ] Jan [ ] Feb
[X]
[X]
Thermostat Schedule: HERS 2006 Reference
Hours
9 10
11
12
Schedule Type
1
2
3 4
5 6
7
8
Cooling (4VD) PM
80
78
78
78
78
78 78
80
78
80
78
80
80 80
78
Cooling (WEH)
PM
78
78
80
78 78
80
78
80
78
80
80
80 80
78 78
Heating (WD) PM
68
65
68 65
68 68
68
68
68 68
68
68
68
68
Heating (WEH) PM
68
68
68 68
68 65
68
68
68 68
68
68
68
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft2
Oft
0.3
FAMILY RM
Default(8 lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(81bs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 3
Defautt(8 Ibs/sq.ft.
ft2
0.3
HALLWAY
Defautt(81bs/sq.ft.
ft2
ft
0.3
AHU
Default(81bs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(81bs/sq.ft.
ft?
ft
0.3
NOOK
Default(8 lbs/sq.ft.
ft2
ft
0.3
LIVING RM
Default(81bs/sq.ft.
ft2
ft
0.3
DINNING RM
Default(B Ibs/sq.ft.
ft
ft
0.3
M TOILET
Default(8 lbs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
M WIC 1
ft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft2
Default(8 lbs/sq.ft.
ft2
ft
0.3
CABANA BATH
Default(81bs/sq.ft.
ft2
ft
0.3
FOYER
Default 8lbs/s .ft.
ft
ft
0.3
STORAGE
10/28/2019 12:09 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: CLARK RESIDENCE Builder Name:
Street: PULITZER ROAD Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
w
Owner: Jurisdiction: ST LUCIE COUNTY
=
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERI
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable Insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints In the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
Ceiling/attic
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
Walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
maintain permanent contact with the underside of
(including
subfloor decking, or floor framing cavity insulation shall
above -garage
be permitted to be in contact with the top side of
and cantilevered floors)
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
be attached to the crawlspace walls.
Class I vapor retarder with overlapping joints taped.
shall permanently
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on installation
Narrow cavities
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Batt insulation shall be cut neatly to fit around wiring a
Plumbing and wiring
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind 1 in and wirin .
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electricat'phone box on
The air barrier shall be installed behind electrical or communication
exteriorwalls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover Plates and walls or ceilings.
a. In addition, inspection or iog wars snap Dein awumaina wwiui u,� N-1-1—o — — --
10/28/201912:10 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software-- Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition 1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family 2. Single-family
b) Return ducts R
6.0
Attic
c) AHU location
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms 4. 3
13. Cooling system: Capacity
SEER
42.0
16.0
a) Split system
5. Is this a worst case? (yes/no) 5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.) 6. 2419
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.411
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.242
c) Area 7c. 318.0
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assem bly
c) Knee walls/skylight walls
d) Radiant barrier installed
10A1.
10A2. 4.1
10B1.
10B2.
11a. 0.0
... _ . -11.b. . .
11 c.
11d. No
14. Heating system: Capacity 27.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
0 Other
15. Water heating system
a) Electric resistance EF 0.98
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
b) Cross ventilation No
- c) Whole house fan No
d) Multizone cooling credit
e) Multizone heating credit
0 Programmable thermostat No
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder
Address of New Home: PULITZER ROAD City/FL Zip: FORT PIERCE FL
10/28/2019 12:10:12 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1