Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: CLARK RESIDENCE Builder Name: SCANNED Street: PULITZER ROAD Permit Office: ST LUCIE COUNTY BY City, State, Zip: FORT PIERCE, FL, Permit Number: St. Lucie COUrIt i/ Jurisdiction: ST LUCIE COUNTY Owner: County: St. Lucie (Florida Climate Zone 2 ) -Design Location: FL, Fort Pierce 1. New construction or ebsbng New (From Plans) 9. Wall Types (2000.0 sqft.) a. Concrete Block - Erd Insul, EMerior Insulation Area R=4.1 2000.00 112 2. Single family or multiple family Single-family b. N/A R= ft 3. Number of units, if multiple family 1 c. N/A R= ft, 3 d. N/A R= ft2 4. Number of Bedrooms 10. Ceiling Types (2419.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2419.00 112 6. Conditioned floor area above grade (ft2) 2419 b. N/A R f 2 R= c. NIA Conditioned floor area below grade (112) 0 11. Ducts R ft2 7. Windows(318.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U-Factor. Sgl, U=0.32 230.00 ft2 SHGC: SHGC=0.22 12. Cooling systems kBtu/hr Efficiency b. U-Factor: Sgl, U=0.65 88.00 ft2 a. Central Unit 42.0 SEER:16.00 SHGC: SHGC=0.30 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor. N/A ft2 a. Electric Strip Heal 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 6.780 ft. 14. Hot water systems Area Weighted Average SHGC: 0.242 a. Electric Cap: 50 gallons 8. Floor Types (2419.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2419.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Total Proposed Modified Loads: 74.93 PASS Glass/FloorArea: 0.131 Total Baseline Loads: 78.24 I hereby certify that the plans and specifications covered by Review of the plans and O�TgE'SpgTA this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates Compliance with the Florida Energy Code. PREP D BY: Before construction is Completed 04 y DATE: this building will be inspected for compliance with Section 553.908 q P r I hereby certify that this uilding, as designed, is in mpliance Florida Statutes. G QD� with the Florida Energy ode. OWNER/AGENT BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 10/28/2019 12:09 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 M RY CHECKLIST REPORT FORM R405-2017 INPUT SUMMA PROJECT, Title: CLARK RESIDENCE Bedrooms: 3 Address Type: Street Address ' Building Type: User Conditioned Area: 2419 Lot# Owner Name: Total Stories: 1 Block/Subdivision: of Units: 1 Worst Case: No PlatBo# Street: : PULIucie ROAD Builder Name: Rotate Angle: 0 No Count: County. St. Lucie Permit Office: ST LUCIE COUNTY Cross Ventilation: City, State, Zip: FORT PIERCE, Jurisdiction: ST LUCIE COUNTY Whole House Fan: No FL, Family Type: Single-family New/Epsting: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2419 24190 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 LAUNDRY RM 214 2140 No 0 1 Yes Yes Yes 2 PANTRY 60 600 No 0 1 No Yes Yes 3 KITCHEN 304 3040 Yes 0 1 Yes Yes Yes 4 DINING ROOM 247 2470 No 0 1 Yes Yes Yes 5 HALL 30 300 No 0 1 No Yes Yes 6 M WIC 77 770 No 0 1 Yes Yes Yes 7 MASTER BEDROO 253 2530 No 0 1 1 Yes Yes Yes 8 DEN 99 990 No 0 1 No Yes Yes 9 M BATH 143 1430 No 0 1 Yes Yes Yes 10 FOYER 132 1320 No 0 1 Yes Yes Yes 11 BATH 2 32 320 No 0 1 No Yes Yes 12 HALLWAY 59 590 No 0 1 No Yes Yes 13 CLST 3 20 200 No 0 1 Yes Yes Yes 14 BEDROOM 3 176 1760 No 0 1 1 Yes Yes Yes 15 BATH 3 48 480 No 0 1 Yes Yes Yes 16 SINKS 3 64 640 No 0 1 Yes Yes Yes 17 BEDROOM 2 177 1770 No 0 1 1 Yes Yes Yes 18 CLST 2 18 180 No 0 1 No Yes Yes 19 LIVING ROOM 266 2660 No 0 1 Yes Yes Yes 10/2812019 12:09 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6111 Edition (2017) Compliant Software Page 2 of 6 ov nUpflvl 1¢T DCDnPT FORM K4Ub-ZUl/ FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet _ 1 Slab -On -Grade Edge Insulation LAUNDRY RM 35 ft 0 214 ft' -- 1 0 0 _ 2 Slab -On -Grade Edge Insulation PANTRY 1 it 0 60 112 -- 1 0 0 3 Slab -On -Grade Edge Insulation KITCHEN 16 It 0 304 ft -- 1 0 0 4 Slab -On -Grade Edge Insulation DINING ROOM 13 It 0 247 ft2 -- 1 0 0 _ 5Slab-On-Grade Edge insulation- HALL 1ft 0 30 112 -- 1 0 0 _ 6 Slab -On -Grade Edge Insulation M WIC 7 It 0 77 112 -- 1 0 0 _ 7SIab-On-Grade Edge Insulation MASTER BEDRO 30 ft 0 253 112 -- 1 0 0 _ 8 Slab -On -Grade Edge Insulation DEN 1 it 0 99 ft2 -- 1 0 0 _ 9 Slab -On -Grade Edge Insulation M BATH lift 0 143112 -- 1 0 0 _ 10SIab-On-Grade Edge Insulation FOYER 6 It 0 132 ft2 -- 1 0 0 _ 11Slab-On-Grade Edge Insulation BATH 2 1 It 0 32 112 -- 1 0 0 _ 12SIab-On-Grade Edge Insulation HALLWAY 1 It 0 59 11 =— 1 0 0 _ 13SIab-On-Grade Edge Insulation CLST 3 2 ft 0 20112 -__ 1 0 0 _ 14SIab-On-Grade Edge Insulation BEDROOM 3 12 It 0 176 112 -- 1 0 0 _ 15SIab-On-Grade Edge Insulation BATH 3 14 It 0 48 ft2 -__ 1 0 0 _ 16SIab-On-Grade Edge Insulation SINKS 3 8 ft 0 64 ft2 -- 1 0 0 _ 17Slab-On-Grade Edge Insulation BEDROOM 2 13 ft 0 177 ft2 -- 1 0 0 _ 18SIab-On-Grade Edge Insulation CLST 2 1 It 0 18 112 -- 1 0 0 19SIab-On-Grade Edge Insulation LIVING ROOM 33 It 0 266 ft2 -- 1 0 0 ROOF, Roof Gable Roof Red Solar SA Emift Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Flat tilelslate 2705 ft2 0 ft2 Medium N 0.6 No 0.9 No 20 26.6 ATTIC J# Type Ventilation Vent Ratio (1 in) Area FIBS IRCC 1 Full attic Unvented 0 2419 ft2 N N 10/28/2019 12:09 PM EnergyGaugeal USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Sofhvare Page 3 of 6 MY CHECKLIST REPORT FORM R405-2017 INPUT SUMIVIA CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frec Truss Type 1 Under Attic(Unvented) LAUNDRY RM 0 Blown 214 ft2 0.1 Wood _ 2 Under Attic(Umrented) PANTRY 0 Blown 60 ft2 0.1 Wood _ 3 Under Attic(Unvented) KITCHEN 0 Blown 304 ft' 0.1 Wood _ 4 Under Attic(Umuenled) DINING ROOM 0 Blown 247 ft2 0.1 Wood _ 5 Under Attic(Unwnted) HALL 0 Blown 30 fP 0.1 Wood _ 6 Under Attic(Unvenled) MWIC 0 Blown 77ft2 .1 Wood _ 7 Under Attic (Unvented) MASTER BEDRO 0 Blown 253-ft2 0.1. Wood _ 8 Under Attic(Unwnted) DEN 0 Blown 99 ft2 0.1 Wood _ 9 Under Attic (Unvenled) M BATH 0 Blown 143 ft2 0.1 Wood _ 10 Under Attic(Unvented) FOYER 0 Blown 132 ft2 0.1 Wood _ 11 Under Attic (Unvented) BATH 2 0 Blown 32 ft2 0.1 Wood _ 12 Under Attic(Unvented) HALLWAY 0 Blown 59 ft2 0.1 Wood _ 13 Under Attic (Unvented) CLST 3 0 Blown 20 112 0.1 Wood _ 14 Under Attic (Unvented) BEDROOM 3 0 Blown 176 ft2 0.1 Wood _ 15 Under Attic (Unvented) BATH 3 0 Blown 48 112 0.1 Wood _ 16 Under Attic(Unvented) SINKS 0 Blown 64 ft2 0.1 Wood _ 17 Under Attic (Unvented) BEDROOM 2 0 Blown 177 ft2 0.1 Wood _ 18 Under Attic(Unvented) CLST2 0 Blown 18 ft2 0.1 Wood _ 19 Under Attic (Unvenled) LIVING ROOM 0 Blown 266 ft2 0.1 Wood WALLS Cavity Width Ht Framing Solar Below Adjacent Space Et_eigh1.t A'aSheathing 1 N Exterior Concrete Block - Ext InsdIAUNDRY R 4.1 19 0 10 0 190.0 ft2 0 0 0.6 0 _ 2 E Exterior Concrete Block - Ext InstUAUNDRY R 4.1 16 0 10 0 160.0 ft2 0 0 0.6 0 _ 3 E Exterior Concrete Block- Ext Insul KITCHEN 4.1 16 0 10 0 160.0 ft2 0 0 0.6 0 _ 4 E Exterior Concrete Block - Ext InsiJINING ROO 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 _ 5 N Exterior Concrete Block - Ext Insul M WIC 4.1 7 0 10 0 70.0 ft2 0 0 0.6 0 _ 6 N Exterior Concrete Block - Ext InsMASTER BE 4.1 15 0 10 0 150.0 ft2 0 0 0.6 0 _ 7 W Exterior Concrete Block - Ext InsLMASTER BE 4.1 15 0 10 0 150.0 ft2 0 0 0.6 0 _ 8 W Exterior Concrete Block - Ext Insul M BATH 4.1 11 0 10 0 110.0 ft2 0 0 0.6 0 _ 9 W Exterior Concrete Block - Ext Insul FOYER 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 _ 10 S Exterior Concrete Block - Ext Insul CLST 3 4.1 2 0 10 0 20.0 ft2 0 0 0.6 0 _ 11 S Exterior Concrete Block - Ext InstSEDR00M 3 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 _ 12 S Exterior Concrete Block - Ext Insul BATH 3 4.1 8 0 10 0 80.0 ft2 0 0 0.6 0 _ 13 W Exterior Concrete Block - Ext Insul BATH 3 4.1 6 0 10 0 60.0 fP 0 0 0.6 0 _ 14 W Exterior Concrete Block - Ext Insul SINKS 3 4.1 8 0 10 0 80.0 ft2 0 0 0.6 0 _ 15 W Exterior Concrete Block - Ext InstBEDROOM 2 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 _ 16 E Exterior Concrete Block - Ext InsdIIVING ROO 4.1 14 0 10 0 140.0 ft2 0 0 0.6 0 _ 17 S Exterior Concrete Block - Ext InSdIIVING ROO 4.1 19 0 10 0 190.0 ft2 0 0 0.6 0 10/28/201912:09 PM EnergyGauge® USA 6.0.02 (Rev, 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 6 ....,.. i.u�n ur rc"r oconGT FORM R405-2017 INru I JUIVIIYIAR r vnwr.�2v 2 DOORS # Omt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 E Insulated LAUNDRY R None .4 3 6 8 20 ft WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang / V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Single Yes 0.32 0.22 N 9.0 T 2 It 0 in 1 ft 4 in None None _ 2 E 2 Vinyl Low-E Single Yes 0.32 0.22 N 15.0 ft2 12 ft 0 in 1 ft 4 in None None _ 3 E 3 Vinyl Low-E Single Yes 0.32 0.22 N 9.0 ft2 12 ft 0 in 1 ft 4 in None None _ 4 E 3 Metal Low-E Single Yes 0.65 0.3 N 48.0 ft2 12 ft 0 in 1 It 4 in None None _ 5 E 4 Vinyl Low-E Single Yes 0.32 0.22 N 40.0 ft- 12 ft 0 in 1 ft 4 in None None _ 6 W 7 Vinyl Low-E Single Yes 0.32 0.22 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None _ 7 W 8 Vinyl Low-E Single Yes 0.32 0.22 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None _ 8 W 9 Metal Low-E Single Yes 0.65 0.3 N 24.0 ft2 2 ft 0 in 1 ft 4 in None None _ 9 S 11 Vinyl Low-E Single Yes 0.32 0.22 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None _ 10 W 13 Vinyl Low-E Single Yes 0.32 0.22 N 12.0 fF 2 ft 0 in 1 ft 4 in None None _ 11 W 15 Vinyl Low-E Single Yes 0.32 0.22 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None _ 12 E 16 Vinyl Low-E Single Yes 0.32 0.22 N 40.0 fl2 12 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 _ 13 S 17 Vinyl Lax-E Single Yes 0.32 0.22 N 30.0 ft2 2 ft 0, in 1 ft 4 in Drapes/blinds Exterior 5 _ 14 W 9 Metal Lax-E Single ' Yes 0.65 0.3 N 16.0 ft2 2 ft 0 in 1 It 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 2822.2 154.93 291.37 .1685 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None C0P:1 27 kBlu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 42 kBtu/hr 1260 din 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None LAUNDRY RM 0.98 50 gal 62.3 gal 120 deg None 10/28/201912:09 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 MARY CHECKLIST REPORT FORM R405-2017 INPUT SUM SOLAR HOT WATER SYSTEM Collector Storage FSEC Cert # Company Name System Model # Collector Model # Area Volume FEF ft,None None DUCTS —Supply-- —Return-- Air CFM 25 CFM25 OUT ON RLF HVAC# Heat Cool # Location R-Value Area Location Area Leakage Type Handler TOT 1 Attic 6 175 ft' Attic 18 ft' -Default Leakage Attic (Default).c(Default) c. 1 1 _ TEMPERATURES Programable[ling[XT]]hermostatr: N Fans: CrMay F:br[X'] Mar]Apr] [oiling I [X] ri Jun Jul r rl Aug [ ] rl Sep ] L 1 Oct Nov trX,]Dec ec [ ]Dec Venting Mar Apr [ May E) Jun 1 Jul I Aug [ 1 Sep lXl [ ] Jan [ ] Feb [X] [X] Thermostat Schedule: HERS 2006 Reference Hours 9 10 11 12 Schedule Type 1 2 3 4 5 6 7 8 Cooling (4VD) PM 80 78 78 78 78 78 78 80 78 80 78 80 80 80 78 Cooling (WEH) PM 78 78 80 78 78 80 78 80 78 80 80 80 80 78 78 Heating (WD) PM 68 65 68 65 68 68 68 68 68 68 68 68 68 68 Heating (WEH) PM 68 68 68 68 68 65 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 Oft 0.3 FAMILY RM Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(81bs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 lbs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Defautt(8 Ibs/sq.ft. ft2 0.3 HALLWAY Defautt(81bs/sq.ft. ft2 ft 0.3 AHU Default(81bs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(81bs/sq.ft. ft? ft 0.3 NOOK Default(8 lbs/sq.ft. ft2 ft 0.3 LIVING RM Default(81bs/sq.ft. ft2 ft 0.3 DINNING RM Default(B Ibs/sq.ft. ft ft 0.3 M TOILET Default(8 lbs/sq.ft. ft2 ft 0.3 M BATH Default(8 lbs/sq.ft. ft2 ft 0.3 M WIC 1 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 Default(8 lbs/sq.ft. ft2 ft 0.3 CABANA BATH Default(81bs/sq.ft. ft2 ft 0.3 FOYER Default 8lbs/s .ft. ft ft 0.3 STORAGE 10/28/2019 12:09 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: CLARK RESIDENCE Builder Name: Street: PULITZER ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: w Owner: Jurisdiction: ST LUCIE COUNTY = Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable Insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints In the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls Walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to maintain permanent contact with the underside of (including subfloor decking, or floor framing cavity insulation shall above -garage be permitted to be in contact with the top side of and cantilevered floors) sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation be attached to the crawlspace walls. Class I vapor retarder with overlapping joints taped. shall permanently Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation Narrow cavities readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be airtight and IC rated. Batt insulation shall be cut neatly to fit around wiring a Plumbing and wiring plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind 1 in and wirin . Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electricat'phone box on The air barrier shall be installed behind electrical or communication exteriorwalls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Plates and walls or ceilings. a. In addition, inspection or iog wars snap Dein awumaina wwiui u,� N-1-1—o — — -- 10/28/201912:10 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software-- Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 Attic c) AHU location 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity SEER 42.0 16.0 a) Split system 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2419 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.411 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.242 c) Area 7c. 318.0 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assem bly c) Knee walls/skylight walls d) Radiant barrier installed 10A1. 10A2. 4.1 10B1. 10B2. 11a. 0.0 ... _ . -11.b. . . 11 c. 11d. No 14. Heating system: Capacity 27.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE 0 Other 15. Water heating system a) Electric resistance EF 0.98 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans b) Cross ventilation No - c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit 0 Programmable thermostat No 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Address of New Home: PULITZER ROAD City/FL Zip: FORT PIERCE FL 10/28/2019 12:10:12 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1