HomeMy WebLinkAboutEVALUATION REPORT - ROOFINGr � � EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORA '29 GA. CLASSIC RIB PANEL' SEP 2 6 2019 ST. Lucie Couna, FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT AWROVAL FL 14645.11-R3 ROOFING SCANNED METAL ROOFING BY St. Lucie County Prepared For: Metal Sales Manufacturing Corporation 545 South 3rd'Street, Suite 200 Louisville, KY 40202 Telephone: (502) 8554300 Fax: (502) 8554200 Prepared By: Bala Sockalingam, Ph:D_ P:E'. Florida Professional.Engineer #62240 1216 N Lansing_Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (866) 366-1543 PT LE COPY R&d1' � R WED FOR CODE COMPLIANCE ST. LUCIE COU TYBOCCW q ff This report consists of Evaluation Report (3 Pages including cover) `���ts��iir���+so� Installation Details (1 Page) �``�,P �'�CKA�.N6 *',, Report No. C2182-11 Date: 9.9.17 CO No 62240 rc 13 STATE OF �0. R( R O Af N, %%% =t� Ll NEW UNDERIAYMEM (REQUIRED ONLY FOR NEW CONSTRUCTION) I PANEL FASTENER CLASSIC RIB SEE DETAIL 1 EXISTIG SHINGLES Imo— 9' (TYP.) SPACING PER ALLOWABLE THIS SHEET (OPTIONAL) PRESSURE TABLE ON THIS SHEET n i \ _ / EXISTING UNDERLAYMENT MINIMUM ATTACHMENT:MIN. 2X— WOOD RAFTER/JOIST/ (OPTIONAL) OR #8 x^2LOLONGI WOOD J SCREWS TRUSS AT MAX. 24' O.C. SPACED ® 6' O.C. IN THE FIELD & AT EDGES FASTENER PATTERN AT INTERMEDIATE LOCATIONS 36' CLASSIC RIB EXISTING SHINGLES NEW UNDERLAYMENT (OPTIONAL) (REQUIRED ONLY FOR NEW CONSTRUCTION) L— EXISTING UNDERLAYMENT /\ � MINIMUM ATTACHMEM: (OPTIONAL) /( 8d x 2.5' LONG RING SHANK NAIL MIN. 2X— WOOD RAFTER/JOIST/ OR #8 x 2' LONG WOOD SCREWS TRUSS AT MAX. 24' O.C. SPACED 0 6' O.C. IN THE FIELD & AT EDGES FASTENER PATTERN AT PANEL ENDS TYPICAL PANEL INSTALLATION X-SECTION I-.— 1 3/4' 1 3/4' 1/4'-14 X 7/8' TEK SCREW NEW UNDERfAYMEM SPACED AT'12' O.C. (REQUIRED ONLY FOR g _ (OPTIOWM.) #9-16 OR fl10-14 WOODSCREWS NEW CONSTRUCTION) _ WITH SELF SEALING WASHER AT EXISTING SHINGLES MAXIMUM SPACING OF 24' O.C. (OPTIONAL) CLASSIC RIB MIN 29 GA. EXISTING UNDERLAYMENT (OPTIONAL) DETAIL 1 PLYWOOD 15/32' THICK (MIN.) 1/4'-14 X 7/8' TEK SCREW SPACED AT 12 O.C. (OPTIONAL) THICK (MIN.) 1/4'-14 X 7/8' TEK SCREW SPACED AT 12' O.C. (OPTIONAL) (MIN.) ALLOWABLE UPLIFT PRESSURE FASTENER PRESSURE SPACING (PSF) (IN) 24 68.4 12 138.5 GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS ARE SHALL BE MIN 29 GA (t = 0.0131. EFFECTIVE COVERING WIDTH OF PANEL = 36'. 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. 01 FL 14645.11-R3 C2182-11 9.9.17 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: Classic Rib Panel Description: 36" wide coverage with (5) 3/4" high ribs Materials: Min. 29 ga., 80 ksi steel or min. 26 ga., 50 ksi steel Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 15/32" thick plywood or min. %" thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017. Deck Attachment: 8d x 2.511 long ring shank nails or #8 x 2" long wood screws @ 6" o.c. (Minimum) in the field and edges. Designed as per FBC 2017. New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1. Required for new construction and optional for reroofing construction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Substrate (optional): Min 1" x 4" No. 2 SYP wood purlins over one layer of asphalt shingles/felt (optional) and min. 15/32" thick plywood deck fastened to supports at maximum 24" o.c. Wood purlins shall be fastened to wood rafters with (2) #9 x 3" long wood screws. The wood purlins will be spaced same as panel fastener spacing along panel length. The wood purlin, purlin to the rafter connection and rafters must be designed by others to the carry the load imposed on the panels and installed as per FBC 2017. Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 68.4 psf @ fastener spacing of 24" o.c. (Factor of Safety = 2) 138.5 psf @ fastener spacing of 12" o.c. Fastener Pattern Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". At panel ends @ 3.511-5.5"-3.5" o.c. across panel width At intermediate @ 9" o.c. across panel width with two fasteners at each sidelap. t FL 14645.11-R3 C2182-11 9.9.17 Page 3 of 3 Sidelap Attachment: /4"-14 x 7/8" long SDS with washer @ 12" o.c. Recommended for (Optional) roof slope less than 3:12. Test Standards: Roof assembly tested in accordance with UL580-94 (Rev 98) `Uplift Resistance of Roof Assemblies' & UL1897-98 `Uplift Tests for Roof Covering Systems' and FM 4470 Section 5.5 `Resistance to Foot Traffic'. Test Equivalency: The test procedures in UL 580-94 comply with test procedures prescribed in UL 580-06. The test procedures in UL 1897-98 comply with test procedures prescribed in UL 1897-12. The test procedure in FM 4470 (1992) comply with test procedure prescribed in FM 4470 (2012). Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: UL580/UL1897 Test Reports Farabaugh Engineering and Testing Inc. Project No. T206-10, Reporting Date 4/27/10 FM 4470 Test Report ENCON Technology Inc. C1587-2, Reporting Date 5/17/08