HomeMy WebLinkAboutDESIGN LOAD COMPLIANCE CERTIFICATEProject Address:
Planning & Development Services Department
Building&Code Regulations Division ERECEIVED
2300 Virginia Avenue, Fort Pierce, FL 34982— (772) 462-25
2019
Certification for Design Load Compliance Permitting
SCANNED
Permit # OccupancvType:�� ConstmceonType: St. Lucie County
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
• Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2017 Building Code Sixth Edition with 20L NIA Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category:_I X II _III_N Exposure Category:_8 X C _D
4. Design Wind Velocity, 160 mph X ASD LRFD End Zone Width: 8 ft
S. Mean Roof Height 18 ft Roof Pitch* 6 .12 Parapet: NIA ft
6. components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, dearly label on all plan openings):
Zone i:+20,0-31sZone 2:+20.0,fi5.3Zone 3:+2o.0, 81.7Zone4:+34.7,-37.6Zone5:!34 �'5Garage: •za.e,-27.7
7. Design Loads: Floor. 100 PSF Roof/Dead: 12 PSF Roof/Uve: 30 Balcony: NIA PSF
Dock NIA PSF Deck: NIA PSF Stairs: NIA PSF Fence: NIA PSF Railings: NIA PSF
8. Were Shear Walls Considered For Structure? Yes X Not Applicable Explain Why Not:
Aspect Ratio <4:1
9. Is A Continuous Load Path Provided? X Yes_Not Applicable Explain WhyNot:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that -structural elements depicted on these plans provide adequate resistance to the design
Donald J. Nuelle
Print Name Cert # & Co. Cert Auth.
Nuelle Engineering 52046
11634 SW Rowena Street, Port St Lucie FL 34987
Company Name & Address
Revised 12/07/2028