Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MW-6 Builder Name: GHO HOMES JNLULiVCjJ Street: 2632 CONIFER DR City, State, Zip: FORT PIERCE, FL, M51 Permit Office: SAINT LUCIE COUNTY Permit Number: �` EP 2 ry Zo�9 Owner. Jurisdiction: Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Clima �bn�)e County, Permitting 1. New construction or existing New (FromPlans)9. Wall Types (1872.9 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1675.30 ft2 b. Frame - Wood, Adjacent R=11.0 197.66 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. NIA _ R= ft2 5. Is this a worst case? No 10. Ceiling Types (1815.0 sqft.) Insulation Area a. Under Attic (Vented) R=40.0 1815.00 ft2 6. Conditioned floor area above grade (ft2) 1815 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7, Wind s(190.3 sqft.) Description Area a. Sup: Attic, Rat Attic, AH: Main 6 567 a. actor: Dbl, U=0.62 190.33 ft2 SHGC: SHGC=0.26 SCANNEC b. U-Factor: N/A ft212. Cooling systems BY Btu/hr Efficiency SHGC: a. Central Unit 35.0 SEER:16.00 St. Lucie County c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 24.8 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 0.000 Area Weighted Average SHGC: 0260' 14. Hot water systems 8. Floor Types (1815.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1815.00 ft2 b. Conservation features EF: 0.940 b. N/A R= ft2 None c. N/A R= ki 15. Credits Pstat Glass/Floor Area: 0.105 Total Proposed Modified Loads: 57.30 PASS Total Baseline Loads: 60.99 I hereby certify that the tans an spe 'ficatio covered by Review of the plans and STq?8 this calculation are in cc lianc with t a En rgy specifications covered by this �F'S1iE as O Code. u� calculation indicates compliance y F :s -, with the Florida Energy Cade. m,_,,.1�,' •;.. „ O PREPARED BY: Before construction is completed r DATE: 0 0/19 this building will be inspected for compliance with Section 553.90E O ° o I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G0p we OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakag , no greaterithan 7,.0 Ha() (R402.4.1.2). 8/14/2019 5:06 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-68 Bedrooms: 3 User Conditioned Area: 1815 Total Stories: 1 1 Worst Case: No GHO HOMES Rotate Angle: 0 SAINT LUCIE COUNTY Cross Ventilation: No Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # Block/Subdivision: PlalBook: Street: 2632 CONIFER DR County: St. Lucie City, State, Zip: FORT PIERCE, FL, 34951 CLIMATE _ / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 1815 16879.5 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1815 16879.5 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 170.5 ft 1815 ft2 __ 0 0 1 ROOF _ / V # Type Roof Gable Roof Materials Area Area Color Red Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul.. (deg) 1 Hip Concrete 2030 ft2 0 ft2 Medium N 0.4 N 0.9 No 0 26.6 ATTIC / V - # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vente 150 1815 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 40 Blown 1815 ft2 0.1 Wood 811412019 5:06 PM EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 N Exterior Concrete Block- Ext Insul Main 4.1 19 6 9 4 182.0 ft' 0 0 0.3 0 -2 E Exterior Concrete Block- Ext Insul Main 4.1 60 0 9 4 560.0 ft' 0 0 0.3 0 -3 S Exterior Concrete Block- Ext Insul Main 4.1 43 7 9 4 406.8 ft' 0 0 0.3 0 -4 W Exterior Concrete Block- Ext Insul Main 4.1 56 5 9 4 526.6 ft' 0 0 0.3 0 5 - Garage Frame - Wood Main 11 21 2 9 4 197.6 ft' 0 0.25 0.3 0 WINDOWS Orientation shown he entered, Pro osed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC :Factor SH _ Imp Area epthgSeparati 4 Int Shade Screening 1 N 1 Metal Double (Clear) Yes 0.62 0.26 N 26.0 ft' MT in 'Oft 0 In None None 2 E 2 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft' 0 ft 0 in 0 ft 0 in None None 3 S 3 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft' 0 ft 0 in 0 ft 0 in None None 4 S 3 Metal Double (Clear) Yes 0.62 0.26 N 26.0 ft' 0 ft 0 in 0 ft 0 in None None 5 s 3 Metal Double (Clear) Yes 0.62 0.26 N 64.0 ft' 0 ft 0 in 0 ft 0 in None None 6 W 4 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft' 0 ft 0 in 0 ft 0 in None None 7 W 4 Metal Double (Clear) Yes 0.62 0.26 N 7.0 ft' 0 ft 0 in 0 It 0 in None None 8 W 4 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft' 0 ft 0 in 0 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 526 ft' 526 ft' 64 ft 9.3 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000414 1969.3 108.11 203.32 .1522 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat' None CORI 24.82 kBlu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit' Split SEER: 16 35 kBtu/hr cfm 0.7 1 sys#1 8/14/2019 5:06 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.94 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft- DUCTS _ / —Supply— —Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 667 ft' Attic 389 fP Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programabie Thermostat: Y Ceiling Fans: , CoolingJan Feb He Jan Feb Mar Mar r Apr [ Apr [ ] Ma ] May [X] Jun [X] Jul [ ] Jun [ ] Jul Aug1 Au[) Se SeP ] E ]Oct Oct [ ] [X] Nov Nov r' Dec [XJ Dec Ventin Jan Feb Mar Apr [ 1 May l) Jun [) Jul Aug [) Se [Xl Oct lx) Nov [ 1 Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main ' 8/14/2019 5:06 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location $ insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b)Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 35.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Condifloned floor area (sq. ft.) 6. 1815 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 c) Area 7c. 190.3 8. Skylights a) U-factor:(weighted average) Be. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 10A1. 10A2. 4.1 14. Heating system: Capacity 24.8 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.94 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 10131. 11.0 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11 a. 40.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be czz on installed code ompliant features. Builder Signature: Date: 1} I I Ivl Address of New Home: 2632 CONIFER DR City/FL Zip: FORT PIERCE, FL 34951 8/14/2019 5:06:45 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit #: Job Information Builder: GHO HOMES Community: Lot: NA Address: 2632 CONIFER DR City: FORT PIERCE State: FL Zip: 34951 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive; or ERI Method O PRESCRIPTIVE METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate ofnot ..exceeding 7 air changes per hour atapressure of 0.21nch w.g. (50 Pascals) in Climate Zones 1 and 2. O PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACHIM) value, as shown on Form R405-2017 (Performance) or R406-2017(ERI), section labeled as Infiltration, sub -section ACH50. ACH(50) specified on Form R405-2017-Energy Cale (Performance) or R406-2017 (ERI): Z000 x 60 * 16880 — Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans ❑ PASS • Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) Testing shall be conducted by either individuals as defined In Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (1) or an approved third party. Awritten report of the results of the test shall be signed by the party conducting the test and provided to thecods official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 8/14/2019 5:07:22 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 -- wrightsoft° Load Short Form Entire House Project Information For: MW-68 JEM 2632 CONIFER DR, FORT PIERCE, FL 34951 Job: Date: Aug 13, 2019 By: Design Information Htg Clg Infiltration Outside db (°F) 43 91 Method Simplified Inside db (°F) 70 72 Construction quality Average Design TD (°F) 27 19 Fireplaces 0 Daily range - L Inside humidity (°/a) 30 50 Moisture difference (gr/lb) 0 65 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade 14ACX SERIES Model Cond 14ACX-036-230-14 AHRI ref Coil CBX27UH-036-230e++TDR AHRI ref 5185998 Efficiency 100 EFF Efficiency 13.2 EER, 16 SEER Heating input 7.3 kW Sensible cooling 24500 Btuh Heating output 24817 Btuh Latent cooling 10500 Btuh Temperature rise 19 °F Total cooling 35000 Btuh Actual air flow 1167 cfm Actual air flow 1167 cfm Air flow factor 0.049 drn/Btuh Air flow factor 0.054 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.64 ROOM NAME Area OF) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) MASTER SUITE 312 4911 3461 241 187 HER WIC 60 939 427 46 23 MASTER BATH 169 1815 2161 89 117 BED 2 205 2429 3254 119 176 UTILITY 72 815 1001 40 54 BATH 2 79 79 217 4 12 FOYER 90 782 590 38 32 DINING 131 3812 2826 187 153 KITCHEN 153 1768 2239 87 121 BED 3 179 3354 2253 165 122 nMo Ar one ocn omc n., .,° .r e., .11 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Aug-1415:50:36 �C wrightSoft' RightSuite®Universa1201212.1.O5RSU02818 Pagel /iLrCd\ MUsetsUas°nlDocumentslWrlghtsoft FIVACXMWEB.rup Cale =MJS Front Door laces: N Entire House 1811 23779 21578 1167 1167 Other equip loads 0 0 Equip. @ 0.95 RSM 20607 Latent cooling 12110 TI'1TA1 c I �o.rn I I I .1•c-s v 1�LV I.11 GJI 10 JLI IV IIVI IIUI Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Aug-1415:50:36 ti wrightsofY RlghtSuite& Universal 201212.1.05 RSU02818 Paget C:1UsersUasonlCocuments\Wrightson HVACIMW-68.rup CaIc=MJB Front Door faces: N - wrightsoftProject Summary Entire House Project Information For: MW-68 JEM 2632 CONIFER DR, FORT PIERCE, FL 34951 Notes: Weather: Vero Beach Municipal AP, FL, US Job: Date: Aug 13, 2019 By: Winter Design Conditions Summer Design. Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 72 OF Design TO 27 OF Design TO 19 OF Daily range L Relative humidity 50 % Moisture difference 65 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20591 Btuh Structure 18159 Btuh Ducts 3188 Btuh Ducts 3418 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23779 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 20607 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 10585 Btuh Ducts 1525 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 1811 1811 Equipment latent load 12110 Btuh Volume (f o) 17872 17872 Air changes/hour 0.38 0.20 Equipment total load 32716 Btuh Equiv. AVF (cfm) 113 60 Req. total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Lennox Trade Trade 14ACX SERIES Model Cond 14ACX-036-230-14 AHRI ref Coil CBX27UH-036-230*++TDR AHRI ref 5185998 Efficiency 100 EFF Efficiency 13.2 EER, 16 SEER Heating input 7.3 kW Sensible cooling 24500 Btuh Heating output 24817 Btuh Latent cooling 10500 Btuh Temperature rise 19 OF Total cooling 35000 Btuh Actual air flow 1167 cfm Actual air flow 1167 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.054 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.64 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsofC 2019-Aug-1415:50:36 g RlghtSuile® Universal 201212.1.05 RSU02818 Page 1 ""`^` C:\Uses\lason1Docunnents\Wdghtsoft HVAC1MW-68.rup Calc=M.18 Front Door faces: N MASTER SUITE COV. PATIO loxlox8 18] CFM TS ATSH LBE W MFF HOR awF YOFMAINRt m GREAT ROOM i ai loxloxo 170OFM DINING m KITCHEN J 6.6.4 BEDROOM 2 n n1r RAG. 10x10.6 WI6'O BY 178 CFM FLE% 50 M XHAUST 6x6x 24NI • 12 CFM RAG. 4V DR1 2 WI 1OV ❑ EXHAU FLEX ®UTILITY 8 xex5 5CM Y 6x6x5 32C M 77 r� FOYER PORCH ®1n1r RAG. I0x V. 122 VGFLE% F/ BEDROOM 3 II TWO BAY GARAGE II OO NOT S0NLEf s V J W CN DL [1 � w I z DUc ow U � (^ LN K V NO