HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MW-6
Builder Name: GHO HOMES
JNLULiVCjJ
Street: 2632 CONIFER DR
City, State, Zip: FORT PIERCE, FL, M51
Permit Office: SAINT LUCIE COUNTY
Permit Number:
�` EP 2 ry Zo�9
Owner.
Jurisdiction:
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Clima
�bn�)e County, Permitting
1. New construction or existing New (FromPlans)9.
Wall Types (1872.9 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1675.30 ft2
b. Frame - Wood, Adjacent
R=11.0 197.66 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. NIA
_
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1815.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=40.0 1815.00 ft2
6. Conditioned floor area above grade (ft2) 1815
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7, Wind s(190.3 sqft.) Description Area
a. Sup: Attic, Rat Attic, AH: Main
6 567
a. actor: Dbl, U=0.62 190.33 ft2
SHGC: SHGC=0.26
SCANNEC
b. U-Factor: N/A ft212.
Cooling systems BY
Btu/hr Efficiency
SHGC:
a. Central Unit 35.0 SEER:16.00
St. Lucie County
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
24.8 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 0.000
Area Weighted Average SHGC: 0260'
14. Hot water systems
8. Floor Types (1815.0 sqft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1815.00 ft2
b. Conservation features
EF: 0.940
b. N/A R= ft2
None
c. N/A R= ki
15. Credits
Pstat
Glass/Floor Area: 0.105 Total Proposed Modified Loads: 57.30
PASS
Total Baseline
Loads: 60.99
I hereby certify that the tans an spe 'ficatio covered by
Review of the plans and
STq?8
this calculation are in cc lianc with t a En rgy
specifications covered by this
�F'S1iE
as O
Code. u�
calculation indicates compliance
y
F :s
-,
with the Florida Energy Cade.
m,_,,.1�,' •;.. „ O
PREPARED BY:
Before construction is completed
r
DATE: 0 0/19
this building will be inspected for
compliance with Section 553.90E
O
° o
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
G0p we
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakag , no greaterithan 7,.0 Ha() (R402.4.1.2).
8/14/2019 5:06 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
MW-68 Bedrooms: 3
User Conditioned Area: 1815
Total Stories: 1
1 Worst Case: No
GHO HOMES Rotate Angle: 0
SAINT LUCIE COUNTY Cross Ventilation: No
Whole House Fan: No
Single-family
New (From Plans)
Address Type: Street Address
Lot #
Block/Subdivision:
PlalBook:
Street: 2632 CONIFER DR
County: St. Lucie
City, State, Zip: FORT PIERCE,
FL, 34951
CLIMATE
_ /
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1815 16879.5
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
Main
1815 16879.5 Yes 4
3 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 170.5 ft
1815 ft2 __ 0 0 1
ROOF
_ /
V #
Type
Roof Gable Roof
Materials Area Area Color
Red Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul.. (deg)
1
Hip
Concrete 2030 ft2 0 ft2 Medium
N 0.4 N 0.9 No 0 26.6
ATTIC
/
V - #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vente 150 1815 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 40 Blown
1815 ft2 0.1 Wood
811412019 5:06 PM EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Below
_ 1
N
Exterior Concrete Block- Ext Insul Main
4.1 19 6 9
4 182.0 ft'
0
0 0.3
0
-2
E
Exterior Concrete Block- Ext Insul Main
4.1 60 0 9
4 560.0 ft'
0
0 0.3
0
-3
S
Exterior Concrete Block- Ext Insul Main
4.1 43 7 9
4 406.8 ft'
0
0 0.3
0
-4
W
Exterior Concrete Block- Ext Insul Main
4.1 56 5 9
4 526.6 ft'
0
0 0.3
0
5
-
Garage Frame - Wood Main
11 21 2 9
4 197.6 ft'
0
0.25 0.3
0
WINDOWS
Orientation shown he entered, Pro osed orientation.
/
Wall
Overhang
V
#
Omt ID Frame Panes NFRC
:Factor SH _ Imp
Area epthgSeparati 4
Int Shade
Screening
1
N 1 Metal Double (Clear) Yes
0.62 0.26 N
26.0 ft' MT in
'Oft 0 In
None
None
2
E 2 Metal Double (Clear) Yes
0.62 0.26 N
12.0 ft' 0 ft 0 in
0 ft 0 in
None
None
3
S 3 Metal Double (Clear) Yes
0.62 0.26 N
21.7 ft' 0 ft 0 in
0 ft 0 in
None
None
4
S 3 Metal Double (Clear) Yes
0.62 0.26 N
26.0 ft' 0 ft 0 in
0 ft 0 in
None
None
5
s 3 Metal Double (Clear) Yes
0.62 0.26 N
64.0 ft' 0 ft 0 in
0 ft 0 in
None
None
6
W 4 Metal Double (Clear) Yes
0.62 0.26 N
12.0 ft' 0 ft 0 in
0 ft 0 in
None
None
7
W 4 Metal Double (Clear) Yes
0.62 0.26 N
7.0 ft' 0 ft 0 in
0 It 0 in
None
None
8
W 4 Metal Double (Clear) Yes
0.62 0.26 N
21.7 ft' 0 ft 0 in
0 ft 0 in
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
526 ft' 526 ft'
64 ft
9.3 ft
1
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000414
1969.3 108.11 203.32 .1522
7
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat' None
CORI
24.82 kBlu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype
Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit' Split
SEER: 16
35 kBtu/hr
cfm
0.7 1
sys#1
8/14/2019 5:06 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
Main
0.94
50 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft-
DUCTS
_ / —Supply—
—Return
Air
CFM 25
CFM25
HVAC#
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT
ON RLF
Heat Cool
1 Attic
6 667 ft'
Attic
389 fP
Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programabie Thermostat: Y
Ceiling Fans:
,
CoolingJan Feb
He Jan Feb
Mar
Mar
r Apr [
Apr [
] Ma
] May
[X] Jun [X] Jul
[ ] Jun [ ] Jul
Aug1
Au[)
Se
SeP
]
E ]Oct
Oct [ ]
[X]
Nov
Nov
r' Dec
[XJ Dec
Ventin Jan Feb
Mar
Apr [
1 May
l) Jun [) Jul
Aug
[) Se
[Xl
Oct lx)
Nov
[ 1 Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4
5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78 78
78
78 78
78
78
80
80
80
80
PM
80
80 78
78
78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78 78
78
78 78
78
78
78
78
78
78
PM
78
78 78
78
78 78
78
78
78
78
78
78
Heating (WD) AM
66
66 66
66
66 68
68
68
68
68
68
68
PM
68
68 68
68
68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66 66
66
66 68
68
68
68
68
68
68
PM
68
68 68
68
68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft'
0 ft
0.3
Main
'
8/14/2019 5:06 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1.
New (From Plans)
12. Ducts, location $ insulation level
a) Supply ducts
R
6.0
2. Single-family or multiple -family
2.
Single-family
b)Return ducts
R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system:
Capacity
35.0
a) Split system
SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package
SEER
c) Ground/water source
SEER/COP
6. Condifloned floor area (sq. ft.)
6.
1815
d) Room unit/PTAC
EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.620
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260
c) Area 7c. 190.3
8. Skylights
a) U-factor:(weighted average) Be. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
10A1.
10A2. 4.1
14. Heating system: Capacity 24.8
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.94
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatRec%
g) Other
10131. 11.0
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11 a. 40.0
b) Cross ventilation No
11b.
c) Whole house fan No
11c.
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be czz
on installed code ompliant features.
Builder Signature: Date: 1} I I Ivl
Address of New Home: 2632 CONIFER DR City/FL Zip: FORT PIERCE, FL 34951
8/14/2019 5:06:45 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction:
Permit #:
Job Information
Builder: GHO HOMES Community: Lot: NA
Address: 2632 CONIFER DR
City: FORT PIERCE State: FL Zip: 34951
Air Leakage Test Results Passing results must meet either the Performance, Prescriptive; or ERI Method
O PRESCRIPTIVE METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate ofnot ..exceeding 7 air
changes per hour atapressure of 0.21nch w.g. (50 Pascals) in Climate Zones 1 and 2.
O PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding
the selected ACHIM) value, as shown on Form R405-2017 (Performance) or R406-2017(ERI), section labeled as Infiltration, sub -section ACH50.
ACH(50) specified on Form R405-2017-Energy Cale (Performance) or R406-2017 (ERI): Z000
x 60 * 16880 — Method for calculating building volume:
CFM(50) Building Volume ACH(50) O Retrieved from architectural plans
❑ PASS • Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals)
Testing shall be conducted by either individuals as defined In Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f), (g), or (1) or an approved third party. Awritten report of the results of the test shall be signed by the party conducting the test and
provided to thecods official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Testing Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
8/14/2019 5:07:22 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
-- wrightsoft° Load Short Form
Entire House
Project Information
For: MW-68 JEM
2632 CONIFER DR, FORT PIERCE, FL 34951
Job:
Date: Aug 13, 2019
By:
Design
Information
Htg
Clg
Infiltration
Outside db (°F)
43
91
Method
Simplified
Inside db (°F)
70
72
Construction quality
Average
Design TD (°F)
27
19
Fireplaces
0
Daily range
-
L
Inside humidity (°/a)
30
50
Moisture difference (gr/lb)
0
65
HEATING EQUIPMENT
COOLING EQUIPMENT
Make
Make Lennox
Trade
Trade 14ACX SERIES
Model
Cond 14ACX-036-230-14
AHRI ref
Coil CBX27UH-036-230e++TDR
AHRI ref 5185998
Efficiency
100 EFF
Efficiency 13.2 EER,
16 SEER
Heating input
7.3
kW
Sensible cooling
24500 Btuh
Heating output
24817
Btuh
Latent cooling
10500 Btuh
Temperature rise
19
°F
Total cooling
35000 Btuh
Actual air flow
1167
cfm
Actual air flow
1167 cfm
Air flow factor
0.049
drn/Btuh
Air flow factor
0.054 cfm/Btuh
Static pressure
0
in H2O
Static pressure
0 in H2O
Space thermostat
Load sensible heat ratio
0.64
ROOM NAME
Area
OF)
Htg load
(Btuh)
Clg load
(Btuh)
Htg AVF
(cfm)
Clg AVF
(cfm)
MASTER SUITE
312
4911
3461
241
187
HER WIC
60
939
427
46
23
MASTER BATH
169
1815
2161
89
117
BED 2
205
2429
3254
119
176
UTILITY
72
815
1001
40
54
BATH 2
79
79
217
4
12
FOYER
90
782
590
38
32
DINING
131
3812
2826
187
153
KITCHEN
153
1768
2239
87
121
BED 3
179
3354
2253
165
122
nMo Ar one
ocn
omc
n., .,°
.r e.,
.11
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2019-Aug-1415:50:36
�C wrightSoft' RightSuite®Universa1201212.1.O5RSU02818 Pagel
/iLrCd\ MUsetsUas°nlDocumentslWrlghtsoft FIVACXMWEB.rup Cale =MJS Front Door laces: N
Entire House
1811
23779
21578
1167
1167
Other equip loads
0
0
Equip. @ 0.95 RSM
20607
Latent cooling
12110
TI'1TA1 c
I �o.rn
I
I
I .1•c-s
v 1�LV I.11 GJI 10 JLI IV IIVI IIUI
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2019-Aug-1415:50:36
ti wrightsofY RlghtSuite& Universal 201212.1.05 RSU02818 Paget
C:1UsersUasonlCocuments\Wrightson HVACIMW-68.rup CaIc=MJB Front Door faces: N
- wrightsoftProject Summary
Entire House
Project Information
For: MW-68 JEM
2632 CONIFER DR, FORT PIERCE, FL 34951
Notes:
Weather: Vero Beach Municipal AP, FL, US
Job:
Date: Aug 13, 2019
By:
Winter Design Conditions
Summer Design. Conditions
Outside db 43
OF
Outside db
91
OF
Inside db 70
OF
Inside db
72
OF
Design TO 27
OF
Design TO
19
OF
Daily range
L
Relative humidity
50
%
Moisture difference
65
gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 20591
Btuh
Structure
18159
Btuh
Ducts 3188
Btuh
Ducts
3418
Btuh
Central vent (0 cfm) 0
Btuh
Central vent (0 cfm)
0
Btuh
Humidification 0
Btuh
Blower
0
Btuh
Piping 0
Btuh
Equipment load 23779
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Infiltration
Equipment sensible load
20607
Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
10585
Btuh
Ducts
1525
Btuh
Heating
Cooling
Central vent (0 cfm)
0
Btuh
Area (ft2) 1811
1811
Equipment latent load
12110
Btuh
Volume (f o) 17872
17872
Air changes/hour 0.38
0.20
Equipment total load
32716
Btuh
Equiv. AVF (cfm) 113
60
Req. total capacity at 0.70 SHR
2.5
ton
Heating Equipment Summary Cooling Equipment Summary
Make
Make Lennox
Trade
Trade 14ACX SERIES
Model
Cond 14ACX-036-230-14
AHRI ref
Coil CBX27UH-036-230*++TDR
AHRI ref 5185998
Efficiency
100 EFF
Efficiency 13.2 EER, 16 SEER
Heating input
7.3
kW
Sensible cooling
24500
Btuh
Heating output
24817
Btuh
Latent cooling
10500
Btuh
Temperature rise
19
OF
Total cooling
35000
Btuh
Actual air flow
1167
cfm
Actual air flow
1167
cfm
Air flow factor
0.049
cfm/Btuh
Air flow factor
0.054
cfm/Btuh
Static pressure
0
in H2O
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
0.64
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri htsofC 2019-Aug-1415:50:36
g RlghtSuile® Universal 201212.1.05 RSU02818 Page 1
""`^` C:\Uses\lason1Docunnents\Wdghtsoft HVAC1MW-68.rup Calc=M.18 Front Door faces: N
MASTER SUITE
COV. PATIO
loxlox8
18] CFM
TS ATSH LBE W MFF
HOR awF YOFMAINRt m
GREAT ROOM i ai
loxloxo
170OFM
DINING m KITCHEN
J
6.6.4
BEDROOM 2
n
n1r
RAG.
10x10.6
WI6'O BY 178 CFM
FLE%
50 M
XHAUST
6x6x
24NI •
12 CFM
RAG.
4V DR1
2
WI 1OV ❑
EXHAU
FLEX
®UTILITY
8 xex5
5CM
Y
6x6x5
32C M
77
r�
FOYER
PORCH
®1n1r
RAG.
I0x
V.
122 VGFLE%
F/
BEDROOM 3
II TWO BAY GARAGE II
OO NOT S0NLEf s
V J
W
CN
DL
[1
� w
I
z DUc
ow
U �
(^
LN K
V
NO