HomeMy WebLinkAboutDESIGN LOAD COMPLIANCE CERTIFICATES' L 10 t Planning & Development Services Department
• Building& Code Regulations Division I RECEIVED
-- - - -- — 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-15 3
SEP 2 7 2019
Certification for Design Load Compliance
ST. Lucie County, Permitting
Project Name:
Project Address: C 2Lo�� 0VNj-r-e Y' priyl SCANNED
St. Lucie County
Permit#: Occupancy Type: &Eg —Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2017 Building Code Sixth Edition with 20 N/A Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category:_I X II _III_IV Exposure Category: B X C _D
4. Design Wind Velocity 160 mph X ASD LRFD End Zone Width: 6 ft
S. Mean Roof Height 18 ft Roof Pitch: 6 12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, Beady label on all plan openings):
Zone 1:+20,-31.8Zone 2'+20.0,-55.3 Zone 3:+20.0,-81.7 Zone 4:+34'7,-37.6 Zone 5:+34'7'-46'5 Garage: +24.91-27.7
7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Uve: 30 Balcony: N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered Forstructure7_Yes X Not Applicable Explain Why Not:
Aspect Ratio <4:1
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that.structural elements depicted on these plans provide adequate resistance to the design
Donald Nuelle
Print Name
Nuelle Er
11634 SW Rowena Street, Port St.mle,�(9 �r®��TY
Company Name & Address BOCC
Revised 12/07/2018