Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ' Project Name: MW-67 Builder Name: GHO HOMES SCANNED 2634 CONIFER DR Permit Office: SAINT LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: BY Owner: Jurisdiction: St. Lucie County Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1872.9 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1675.30 ft' b. Frame - Wood, Adjacent R=11.0 197.56 112 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1815.0 soft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=40.0 1815.00 ft2 6. Conditioned floor area above grade (112) 1815 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(190.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 567 a., U-Factor: Dbl, U=0.62 190.33 ft2 ' SHGC: SHGC=0.26 b., U-Factor: N/A ft2 12. Cooling systems RECEIVE u i fficiency - SHGC: a. Central. Unit 35.0 SE R:16.00 c. U-Factor: NIA ft2 SEP 2 7 2kt9u/hr SHGC SHGC: 13. Heating systems Efficiency d. U-Factor: NIA ft2 a. Electric Strip H at 24.8 OP:1.00 SHGC: Sr. Lucie County, Permitting Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1815.0 soft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1815.00 112 b. Conservation features b. N/A R= 112 None c. N/A R= ft2 15. Credits Patel Glass/Floor Area: 0.105 Total Proposed Modified Loads: 57.30 PASS Total Baseline Loads: 60.99 1 hereby certify that the plans and ecificat ns cov red by Review of the plans and FTKE S741, this calculation are in compliance wit: rida E rgy specifications covered by this _ ;60A Code. r"" calculation indicates compliance with the Florida Energy Code. nn, 7�('••%, ``r?.,;;'.•�°`P„ l0� PREPARED BY: Before construction is completed DATE: 8/14/19 this building will be inspected for compliance with Section 553.908 0 'it'll A • I hereby certify that this building, as designed, i in compliance Florida Statutes. with the Florida Energy Code.1,COD WE'C¢J OWNER/AGENT: `A BUILDING OFFICIAL: DATE: 52 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 8/14/2019 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: _ # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-67 Bedrooms: 3 User Conditioned Area: 1815 Total Stories: 1 1 Worst Case: No GHO HOMES Rotate Angle: 0 SAINT LUCIE COUNTY Cross Ventilation: No Whole House Fan: No Single-family New (FromPlans) Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 2634 CONIFER DR County: St. Lucie City, Stale, Zip: FORT PIERCE, FL, 34951 CLIMATE _ / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST LUCIE CO INTL FL VERO BEACH MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 1815 16879.5 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1815 16879.5 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 170.5 It 1816 ft2 _-- 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Rad Barr Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) 1 Hip Concrete 2030 ft2 0 ft2 Medium N 0.4 N 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1815 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 40 Blown 1815 ft2 0.1 Wood 8/14/2019 4:49 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below e Typ„ Space R-Valu= Ft In Ft - ra ° _ 1 N Exterior Concrete Block - Ext Insul Main 4.1 19 6 9 4 182.0 ft' 0 0 0.3 0 -2 E Exterior Concrete Block - Ext Insul Main 4.1 60 0 9 4 560.0 W 0 0 0.3 0 _ 3 S Exterior Concrete Block - Ext Insul Main 4.1 43 7 9 4 406.8 ft' 0 0 0.3 0 -4 W Exterior Concrete Block - Ext Insul Main 4.1 56 5 9 4 526.6 ft' 0 0 0.3 0 5 - Garage Frame - Wood Main 11 21 2 9 4 197.6 ft' 0 0.25 0.3 0 WINDOWS Orientation shown is the entered, Proposed orientation. _ / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Double (Clear) Yes 0.62 0.26 N 26.0 ft' 0 ft 0 in 0 ft 0 in None None 2 E 2 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft' 0 ft 0 in 0 ft 0 in None None 3 S 3 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft' 0 ft 0 in 0 ft 0 in None None _ 4 S 3 Metal Double (Clear) Yes 0.62 0.26 N 26.0 ft' 0 ft 0 in 0 ft 0 in None None _ 5 s 3 Metal Double (Clear) Yes 0.62 0.26 �N 64.0 ft' 0 ft 0 in 0 ft 0 in None None 6 W 4 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft' 0 ft 0 in 0 ft 0 in None None _ 7 W 4 Metal Double (Clear) Yes 0.62 0.26 N 7.0 W 0 ft 0 in 0 ft 0 in None None 8 W 4 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft' 0 ft 0 in 0 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 526 ft' 526 ft' 64 ft 9.3 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000414 1969.3 108.11 203.32 .1522 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None CORI 24.82 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity 'Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 35 kBtu/hr cfm 0.7 1 sys#1 8/14/2019 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.94 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / —Supply--- —Return-- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 567 ft2 Attic 389 112 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programablfe'Thermostat: Ceiling Fans: 'JY Heating Jan Feb Mar Apr, f ] J May �X� Jun [X] Jul [ ] [X] Aug [X] ]Sep [ j L J Oct rNov Nov Dec Dec Venting [ 1 Jan [ 1 Feb l l l l X Mar l� [ Jun [ 1 Jul l 1 Aug E 1 Sep lxl [ Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 112 0 ft 0.3 Main 8/14/2019 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: .. Capacity 35.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEERIGOP 6. Conditioned floor area (sq. ft.) 6. 1815 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 14. Heating system: Capacity 24.8 c) Area 7c. 190.3 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 91b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1, e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 40.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (r exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based R lled code compliant features. Builder Signature: Date: Address of New Home: 2634 CONIFER DR City/FL Zip: FORT PIERCE, FL 34951 8/14/2019 4:50:02 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit #: Job Information - Builder: GHO HOMES Community: Lot: NA Address: 2634 CONIFER DR City: FORT PIERCE State: FL Zip: 34951 Air LeakageTest Results Passing results must meet either the Performance, Prescriptive, orERIMethod O PRESCRIPTIVE METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air- changes per hour at a pressure of 0.2.inch w.g. (50 Pascals) in Climate Zones 1 and 2. O PERFORMANCE orERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on Form R405-2017 (Performance) or R406-2017 (ERI),section labeled as infiltration, sub -section ACH50. ACH(50) speciried on Form. R405-2017-Energy Catc (Performance) or R466-2017 (ERI): Z000 - x 60 _ 16880 — Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans 1-1 PASS • Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third parry. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 8/14/2019 4:50:32 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 1 of 1 wrightsoft° Load Short Form Entire House For: MW-67 2634 CONIFER DR, FORT PIERCE, FL 34951 Htg Clg Outside db (°F) 43 91 Method Inside db (°F) 70 72 Construction quality Design TD (°F) 27 19 Fireplaces Daily range - L Inside humidity (°/a) 30 50 Moisture difference (gr/lb) 0 65 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 7.3 kW 24817 Btuh 19 °F 1167 cfm 0.049 cfm/Btuh 0 in H2O Job: Date: Aug 12, 2019 By: Infiltration Simplified Average 0 COOLING EQUIPMENT Make Lennox Trade 14ACX SERIES Cond 14ACX-036-230-14 Coil CBX27UH-036-230'++TDR AHRI ref 5185998 Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 13.2 EER, 16 SEER 24500 Btuh 10500 Btuh 35000 Btuh 1167 cfm 0.054 cfm/Btuh 0 in H2O 0.64 ROOM NAME Area (ft") Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) MASTER SUITE 312 4911 3461 241 187 HER WIC 60 939 427 46 23 MASTER BATH 169 1815 2161 89 117 BED 2 205 2429 3254 119 176 UTILITY 72 815 1001 40 54 BATH 2 79 79 217 4 12 FOYER 90 782 590 38 32 DINING 131 3812 2826 187 153 KITCHEN 153 1768 2239 87 121 BED 3 179 3354 2253 165 122 rMvAr Mee ocn or-'c •1n Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Aug-1314:29:49 4-.. wrlghtSOit' RightSuite® Universal 201212.1.05 RSU02818 Page 1 Zak C1UsensUason0ccumentAWrightsoft HVACWiW57.rup Calc=MJ8 Front Door faces: N Entire House 1811 23779 21578 1167 1167 Other equip loads 0 0 Equip. @ 0.95 RSM 20607 Latent cooling 12110 T/ IAI o 1 1 I 1 I V I/lLV IVII GJ/IJ JGI IV IIVI IIV! Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ` Wil �1t5Oi 2019-AugA314:29:49 . �, 9 RightSuite® Universa1201212.1.05 RSU02818 Paget /tCrQ1 C:\UsemU.son\DocunnentMWnghtsoR HVAC\MW-87.rup Calc=MJ8 Front Door faces: N FI wrightsoft• Project Summary Entire House Project Information For: MW-67 2634 CONIFER DR, FORT PIERCE, FL 34951 Notes: Design Information Weather: Winter Design Conditions Outside db 43 OF Inside db 70 OF Design TD 27 OF Heating Summary Structure 20591 Btuh Ducts 3188 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 23779 Btuh Method Construction quality Fireplaces Infiltration Vero Beach Municipal AP, FL, US Simplified Average 0 Heating Cooling Area (fta) 1811 1811 Volume (fts) 17872 17872 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 113 60 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 7.3 kW 24817 Btuh 19 OF 1167 cfm 0.049 cfm/Btuh 0 in H2O Job: Date: Aug 12, 2019 By: Summer Design Conditions Outside db 91 OF Inside db 72 OF Design TD 19 OF Daily range L Relative humidity 50 % Moisture difference 65 gr/lb Sensible Cooling Equipment Load Sizing Structure 18159 Btuh Ducts 3418 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 20607 Btuh Latent Cooling Equipment Load Sizing Structure 10585 Btuh Ducts 1525 Btuh Central vent (0 Ffm) 0 Btuh Equipment latent load 12110 Btuh Equipment total load 32716 Btuh Req. total capacity at 0.70 SHR 2.5 ton Cooling Equipment Summary Make Lennox Trade 14ACX SERIES Cord 14ACX-036-230-14 Coil CBX27UH-036-230'++TDR AHRI ref 5185998 Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 13.2 EER, 16 SEER 24500 Btuh 10500 Btuh 35000 Btuh 1167 cfm 0.054 cfm/Btuh 0 in H2O 0.64 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Aug-13 14:29:49 $ Wr19htSOft' RightSuite® Universal 201212.1.05 RSU02818 Page 14ECA CAUsersUasonTocumentsWrightsoft HVACWW-67.mp Calc=MJ8 Front Door faces: N MASTER SUITE COV. PATIO DINING WIC T-STAT SHALL BE WITHIN 3 FEET HORIZONTALLY OF MAIN RETURN GREAT ROOM AHU-1 3-TON 10x 1B.e 13Y CFM 1o.1o.a KITCHEN 153 CFM 6x6.4 BEDROOM 2 6xBx6 33 eB CFM ' R-AO. RAG. 10. 10 FM ` �•o FL9'O V6LFM 9tl FLE% 6'0 9 El 5H S 6.6 4>lr 10 CfM R0.G. P0ORYER A 2 WI PLENUM EXHAUST ABOVE Two ❑ OVE ® UTILITY 6x6.5 M CFM wo 5' 6x6x5 0 m CFM FOYER ro 12- PORCH ®1 -AO. M1x1BxT WI B'O CFM FLEX BEDROOM 3 J — TWO BAY GARAGE DO NOT SCALE PLANS VJ W L m o� � J L W O � Qw U D— O N 1L