HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
' Project Name: MW-67
Builder Name: GHO HOMES
SCANNED
2634 CONIFER DR
Permit Office: SAINT LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, 34951
Permit Number:
BY
Owner:
Jurisdiction:
St. Lucie County
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
9. Wall Types (1872.9 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1675.30 ft'
b. Frame - Wood, Adjacent
R=11.0 197.56 112
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
3
d. N/A
R= ft2
10. Ceiling Types (1815.0 soft.)
Insulation Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=40.0 1815.00 ft2
6. Conditioned floor area above grade (112)
1815
b. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(190.3 sqft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Main
6 567
a., U-Factor: Dbl, U=0.62
190.33 ft2
' SHGC: SHGC=0.26
b., U-Factor: N/A
ft2
12. Cooling systems RECEIVE u i fficiency
- SHGC:
a. Central. Unit
35.0 SE R:16.00
c. U-Factor: NIA
ft2
SEP 2 7
2kt9u/hr
SHGC
SHGC:
13. Heating systems
Efficiency
d. U-Factor: NIA
ft2
a. Electric Strip H at
24.8 OP:1.00
SHGC:
Sr. Lucie County,
Permitting
Area Weighted Average Overhang Depth:
0.000 ft.
Area Weighted Average SHGC:
0.260
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1815.0 soft.) Insulation
Area
EF: 0.940
a. Slab -On -Grade Edge Insulation
R=0.0 1815.00 112
b. Conservation features
b. N/A
R= 112
None
c. N/A
R= ft2
15. Credits
Patel
Glass/Floor Area: 0.105
Total Proposed Modified Loads: 57.30
PASS
Total Baseline
Loads: 60.99
1 hereby certify that the plans and ecificat ns cov red by
Review of the plans and
FTKE S741,
this calculation are in compliance wit:
rida E rgy
specifications covered by this
_ ;60A
Code.
r""
calculation indicates compliance
with the Florida Energy Code.
nn, 7�('••%, ``r?.,;;'.•�°`P„ l0�
PREPARED BY:
Before construction is completed
DATE:
8/14/19
this building will be inspected for
compliance with Section 553.908
0 'it'll A
•
I hereby certify that this building, as designed, i in compliance
Florida Statutes.
with the Florida Energy Code.1,COD
WE'C¢J
OWNER/AGENT: `A
BUILDING OFFICIAL:
DATE: 52
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
8/14/2019 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
_ # of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
MW-67 Bedrooms: 3
User Conditioned Area: 1815
Total Stories: 1
1 Worst Case: No
GHO HOMES Rotate Angle: 0
SAINT LUCIE COUNTY Cross Ventilation: No
Whole House Fan: No
Single-family
New (FromPlans)
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 2634 CONIFER DR
County: St. Lucie
City, Stale, Zip: FORT PIERCE,
FL, 34951
CLIMATE
_ /
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST LUCIE CO INTL FL VERO BEACH MUNI 39 90
70
75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1815 16879.5
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
Main
1815 16879.5 Yes 4
3
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 170.5 It
1816 ft2
_-- 0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad
Barr
Solar SA Emitt Emitt Deck Pitch
Absor. Tested Tested Insul. (deg)
1
Hip
Concrete 2030 ft2 0 ft2 Medium
N
0.4 N 0.9 No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 1815 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 40 Blown
1815 ft2 0.1 Wood
8/14/2019 4:49 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar
Below
e Typ„ Space
R-Valu= Ft In Ft
-
ra °
_ 1
N
Exterior Concrete Block - Ext Insul Main
4.1 19 6 9
4 182.0 ft'
0
0 0.3
0
-2
E
Exterior Concrete Block - Ext Insul Main
4.1 60 0 9
4 560.0 W
0
0 0.3
0
_ 3
S
Exterior Concrete Block - Ext Insul Main
4.1 43 7 9
4 406.8 ft'
0
0 0.3
0
-4
W
Exterior Concrete Block - Ext Insul Main
4.1 56 5 9
4 526.6 ft'
0
0 0.3
0
5
-
Garage Frame - Wood Main
11 21 2 9
4 197.6 ft'
0
0.25 0.3
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
_ /
Wall
Overhang
V
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area Depth
Separation
Int Shade
Screening
1
N 1 Metal Double (Clear) Yes
0.62 0.26 N
26.0 ft' 0 ft 0 in
0 ft 0 in
None
None
2
E 2 Metal Double (Clear) Yes
0.62 0.26 N
12.0 ft' 0 ft 0 in
0 ft 0 in
None
None
3
S 3 Metal Double (Clear) Yes
0.62 0.26 N
21.7 ft' 0 ft 0 in
0 ft 0 in
None
None
_
4
S 3 Metal Double (Clear) Yes
0.62 0.26 N
26.0 ft' 0 ft 0 in
0 ft 0 in
None
None
_
5
s 3 Metal Double (Clear) Yes
0.62 0.26 �N
64.0 ft' 0 ft 0 in
0 ft 0 in
None
None
6
W 4 Metal Double (Clear) Yes
0.62 0.26 N
12.0 ft' 0 ft 0 in
0 ft 0 in
None
None
_
7
W 4 Metal Double (Clear) Yes
0.62 0.26 N
7.0 W 0 ft 0 in
0 ft 0 in
None
None
8
W 4 Metal Double (Clear) Yes
0.62 0.26 N
21.7 ft' 0 ft 0 in
0 ft 0 in
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
526 ft' 526 ft'
64 ft
9.3 ft
1
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000414
1969.3 108.11 203.32 .1522
7
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/ None
CORI
24.82 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype
Efficiency
Capacity 'Air Flow
SHR Block
Ducts
1
Central Unit/ Split
SEER: 16
35 kBtu/hr
cfm
0.7 1
sys#1
8/14/2019 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Main
0.94 50 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
/ —Supply---
—Return--
Air
CFM 25
CFM25
HVAC#
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
ON
RLF
Heat Cool
1 Attic
6 567 ft2
Attic
389 112 Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programablfe'Thermostat:
Ceiling Fans:
'JY
Heating Jan Feb
Mar
Apr,
f ]
J May �X� Jun [X] Jul
[ ]
[X] Aug
[X]
]Sep
[ j
L J Oct
rNov
Nov
Dec
Dec
Venting [ 1 Jan [ 1 Feb
l l l l
X Mar
l�
[
Jun [ 1 Jul
l 1 Aug
E 1 Sep
lxl
[
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD) AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 112
0 ft
0.3
Main
8/14/2019 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: .. Capacity
35.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEERIGOP
6. Conditioned floor area (sq. ft.)
6.
1815
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.620
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.260
14. Heating system: Capacity
24.8
c) Area
7c.
190.3
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
91b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.94
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1,
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a) Ceiling fans
a) Under attic 11a. 40.0 b) Cross ventilation No
b) Single assembly 11b. c) Whole house fan No
c) Knee walls/skylight walls 11c. d) Multizone cooling credit
d) Radiant barrier installed 11d. No e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (r exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based R
lled code compliant features.
Builder Signature: Date:
Address of New Home: 2634 CONIFER DR City/FL Zip: FORT PIERCE, FL 34951
8/14/2019 4:50:02 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction:
Permit #:
Job Information -
Builder: GHO HOMES Community: Lot: NA
Address: 2634 CONIFER DR
City: FORT PIERCE State: FL Zip: 34951
Air LeakageTest Results Passing results must meet either the Performance, Prescriptive, orERIMethod
O PRESCRIPTIVE METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air-
changes per hour at a pressure of 0.2.inch w.g. (50 Pascals) in Climate Zones 1 and 2.
O PERFORMANCE orERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding
the selected ACH(50) value, as shown on Form R405-2017 (Performance) or R406-2017 (ERI),section labeled as infiltration, sub -section ACH50.
ACH(50) speciried on Form. R405-2017-Energy Catc (Performance) or R466-2017 (ERI): Z000 -
x 60 _ 16880 — Method for calculating building volume:
CFM(50) Building Volume ACH(50)
O Retrieved from architectural plans
1-1 PASS • Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f), (g), or (i) or an approved third parry. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Testing Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
8/14/2019 4:50:32 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 1 of 1
wrightsoft° Load Short Form
Entire House
For: MW-67
2634 CONIFER DR, FORT PIERCE, FL 34951
Htg Clg
Outside db (°F)
43
91 Method
Inside db (°F)
70
72 Construction quality
Design TD (°F)
27
19 Fireplaces
Daily range
-
L
Inside humidity (°/a)
30
50
Moisture difference (gr/lb)
0
65
HEATING EQUIPMENT
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
7.3
kW
24817
Btuh
19
°F
1167
cfm
0.049
cfm/Btuh
0
in H2O
Job:
Date: Aug 12, 2019
By:
Infiltration
Simplified
Average
0
COOLING EQUIPMENT
Make
Lennox
Trade
14ACX SERIES
Cond
14ACX-036-230-14
Coil
CBX27UH-036-230'++TDR
AHRI ref
5185998
Efficiency
Sensible cooling
Latent cooling
Total cooling
Actual air flow
Air flow factor
Static pressure
Load sensible heat ratio
13.2 EER, 16 SEER
24500
Btuh
10500
Btuh
35000
Btuh
1167
cfm
0.054
cfm/Btuh
0
in H2O
0.64
ROOM NAME
Area
(ft")
Htg load
(Btuh)
Clg load
(Btuh)
Htg AVF
(cfm)
Clg AVF
(cfm)
MASTER SUITE
312
4911
3461
241
187
HER WIC
60
939
427
46
23
MASTER BATH
169
1815
2161
89
117
BED 2
205
2429
3254
119
176
UTILITY
72
815
1001
40
54
BATH 2
79
79
217
4
12
FOYER
90
782
590
38
32
DINING
131
3812
2826
187
153
KITCHEN
153
1768
2239
87
121
BED 3
179
3354
2253
165
122
rMvAr Mee
ocn
or-'c
•1n
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2019-Aug-1314:29:49
4-.. wrlghtSOit' RightSuite® Universal 201212.1.05 RSU02818 Page 1
Zak C1UsensUason0ccumentAWrightsoft HVACWiW57.rup Calc=MJ8 Front Door faces: N
Entire House
1811
23779
21578
1167
1167
Other equip loads
0
0
Equip. @ 0.95 RSM
20607
Latent cooling
12110
T/ IAI o
1
1
I
1 I
V I/lLV IVII GJ/IJ JGI IV IIVI IIV!
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
` Wil �1t5Oi 2019-AugA314:29:49
.
�, 9 RightSuite® Universa1201212.1.05 RSU02818 Paget
/tCrQ1 C:\UsemU.son\DocunnentMWnghtsoR HVAC\MW-87.rup Calc=MJ8 Front Door faces: N
FI wrightsoft• Project Summary
Entire House
Project Information
For: MW-67
2634 CONIFER DR, FORT PIERCE, FL 34951
Notes:
Design Information
Weather:
Winter Design Conditions
Outside db
43
OF
Inside db
70
OF
Design TD
27
OF
Heating Summary
Structure
20591
Btuh
Ducts
3188
Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
23779
Btuh
Method
Construction quality
Fireplaces
Infiltration
Vero Beach Municipal AP, FL, US
Simplified
Average
0
Heating Cooling
Area (fta) 1811 1811
Volume (fts) 17872 17872
Air changes/hour 0.38 0.20
Equiv. AVF (cfm) 113 60
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
7.3 kW
24817 Btuh
19 OF
1167 cfm
0.049 cfm/Btuh
0 in H2O
Job:
Date: Aug 12, 2019
By:
Summer Design Conditions
Outside db
91
OF
Inside db
72
OF
Design TD
19
OF
Daily range
L
Relative humidity
50
%
Moisture difference
65
gr/lb
Sensible Cooling Equipment Load Sizing
Structure 18159 Btuh
Ducts 3418 Btuh
Central vent (0 cfm) 0 Btuh
Blower 0 Btuh
Use manufacturer's data n
Rate/swing multiplier 0.95
Equipment sensible load 20607 Btuh
Latent Cooling Equipment Load Sizing
Structure 10585
Btuh
Ducts 1525
Btuh
Central vent (0 Ffm) 0
Btuh
Equipment latent load 12110
Btuh
Equipment total load 32716
Btuh
Req. total capacity at 0.70 SHR 2.5
ton
Cooling Equipment Summary
Make Lennox
Trade 14ACX SERIES
Cord 14ACX-036-230-14
Coil CBX27UH-036-230'++TDR
AHRI ref 5185998
Efficiency
Sensible cooling
Latent cooling
Total cooling
Actual air flow
Air flow factor
Static pressure
Load sensible heat ratio
13.2 EER, 16 SEER
24500
Btuh
10500
Btuh
35000
Btuh
1167
cfm
0.054
cfm/Btuh
0
in H2O
0.64
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2019-Aug-13 14:29:49
$ Wr19htSOft' RightSuite® Universal 201212.1.05 RSU02818 Page
14ECA CAUsersUasonTocumentsWrightsoft HVACWW-67.mp Calc=MJ8 Front Door faces: N
MASTER SUITE
COV. PATIO
DINING
WIC
T-STAT SHALL BE WITHIN 3 FEET
HORIZONTALLY OF MAIN RETURN
GREAT ROOM AHU-1
3-TON
10x 1B.e
13Y CFM
1o.1o.a KITCHEN
153 CFM
6x6.4 BEDROOM 2
6xBx6 33
eB CFM
'
R-AO.
RAG. 10. 10 FM `
�•o FL9'O V6LFM 9tl FLE% 6'0 9
El
5H S
6.6 4>lr
10 CfM R0.G. P0ORYER
A 2 WI PLENUM EXHAUST
ABOVE
Two ❑
OVE
® UTILITY
6x6.5
M CFM
wo
5'
6x6x5
0 m CFM
FOYER ro
12- PORCH
®1 -AO.
M1x1BxT
WI B'O CFM
FLEX
BEDROOM 3
J
—
TWO BAY GARAGE
DO NOT SCALE PLANS
VJ
W
L
m
o�
� J
L
W
O
�
Qw
U D—
O
N 1L