Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: REVORD RESIDENCE SCPNIAEU Builder Name: TC CUSTOM HOMES Street: GERMANY CANAL ROAD IV Permit Office: ST LUCIE COUNTY City, Stale, Zip: FORT PIERCE, FL, County Permit Number: Owner. `UC1e St. Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2700.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Ext Insul, Exterior R=4.1 1520.00 W b. Frame- Wood, Exterior R=13.0 1180.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= fe 5. Is this a worst case? No 10. Ceiling Types (2062.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2062.00 ft' 6. Conditioned floor area above grade (ft2) 2062 b. N/A R= ft2 Conditioned floor area below grade (112) 0 c. N/A R= ft' 11. Ducts R ft2 7. Windows(440.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU CLST 6 125 a. U-Factor: SgI, U=0.40 344.00 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 125 SHGC: SHGC=0.25 b. U-Factor: SgI, U=0.45 96.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 17.9 SEER:16.00 c. U-Factor: N/A ft2 b. Central Unit 17.9 SEER:16.00 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.261 14. Hot water systems 8. Floor Types (2062.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab-OnrGrade Edge Insulation R=0.0 1233.00 ft2 b. Conservation features EF: 0.950 b, Raised Floor R=19.0 829.00 f:2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.213 Total Proposed Modified Loads: 72.01 PASS Total Baseline Loads: 77.74 I hereby certify that the plans and specifications covered by Review of the plans and Sr4 this calculation are in compliance with the Florida Energy specifications covered by this 0FTHE - O Code. calculation indicates compliance c y a;, "' °' N 0 with the Florida Energy Code. •..`•':i�••°;,��'„ O� PREPARE BX: Before construction is completed DATE: d this building will be inspected for t0 'Ipi'a A compliance with Section 553.908 • , I hereby certify that this build' g, as signed, is in compliance Florida Statutes. with the Florida Energy C 00p �ygTRV OWNER/AGENT BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE COPY 11/28/2018 11:09 AM EnergyGauge® USA Section R405.4.1 Compliant RECEIVE® DEC -4 2018 Pagel If Permitting Department St. Lucie County, FL *' FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: REVORD RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2062 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: TC CUSTOM HOMES Rotate Angle: 0 Street GERMANY CANAL RO Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE _ / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 1233 12330 2 AHU 2 829 7261.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 KITCHEN 229 2290 Yes 0 1 Yes Yes Yes 2 LIVING ROOM 629 6290 No 0 1 Yes Yes Yes 3 BEDROOM 1 182 1820 No 0 1 1 Yes Yes Yes 4 WIC 25 250 No 0 1 Yes Yes Yes 5 BATH 1 49 490 No 0 1 Yes Yes Yes 6 CLST 9 90 No 0 1 Yes Yes Yes 7 HALL 28 280 No 0 1 Yes Yes Yes 8 AHU CLST 12 120 No 0 1 No Yes Yes 9 UTILITY 70 700 No 0 1 Yes Yes Yes 10 STAIRS UP 42 369.6 No 0 1 Yes Yes Yes 11 BATH 2 72 633.6 No 0 1 Yes Yes Yes 12 CLST 2 6 52.8 No 0 1 No Yes Yes 13 CLST 3 6 52.8 No 0 1 No Yes Yes 14 BEDROOM 2 198 1742.4 No 0 1 1 Yes Yes Yes 15 BEDROOM 3 198 1742.4 No 0 1 1 Yes Yes Yes 16 DEN 307 2667.8 No 0 1 Yes Yes Yes 11/28/2018 11:09 AM EnergyGaugeO USA Section R405A.1 Compliant Software Page 2 of 6 �' FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation KITCHEN 32 it 0 229 ft2 ___ 1 0 0 2 Slab -On -Grade Edge Insulation LIVING ROOM 51 it 0 629 ft2 ___ 1 0 0 3 Slab -On -Grade Edge Insulation BEDROOM 1 22 it 0 182 ft2 1 0 0 4 Slab -On -Grade Edge Insulation WIC 1 lift 0 25 ft2 ___ 1 0 0 5 Slab -On -Grade Edge Insulation BATH 1 7 ft 0 49 ft2 ___ 1 0 0 6 Slab -On -Grade Edge Insulation CLST 3 ft 0 9 ft2 _— 1 0 0 7 Slab -On -Grade Edge Insulation HALL 9 ft 0 28 ft2 _— 1 0 0 8 Slab -On -Grade Edge Insulation AHU CLST 1 ft 0 12 ft2 1 0 0 9 Slab -On -Grade Edge Insulation UTILITY 17 ft 0 70 ft2 — 1 0 0 1013aised Floor STAIRS UP __ __ 42 ft2 19 1 0 0 11Raised Floor BATH 2 __ __ 72 ft2 19 1 0 0 12Raised Floor CLST 2 __ __ 6 ft2 19 1 0 0 13Raised Floor CLST 3 __ __ 6 ft2 19 1 0 0 14Raised Floor BEDROOM 2 __ __ 198 ft2 19 1 0 0 15Raised Floor BEDROOM 3 __ __ 198 ft2 19 1 0 0 162aised Floor DEN ___ ___ 307 ft2 19 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2916 ft2 0 ft2 Medium 0.6 No 0.9 No 20 45 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2062fF N N 11/28/2018 11:09 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6 - FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type _ 1 Under Attic(Unvented) KITCHEN 20 Blown 229 f? 0.1 Wood _ 2 Under Attic(Unvented) LIVING ROOM 20 Blown 629 ft' 0.1 Wood _ 3 Under Attic(Unvented) BEDROOM 20 Blown 182 ft' 0.1 Wood 4 Under Attic (Unvented) WIC 1 20 Blown 25 ft' 0.1 Wood 5 Under Attic(Unvented) BATH 20 Blown 49 ft' 0.1 Wood _ 6 Under Attic(Unvented) CLST 20 Blown 9ft' 0.1 Woad 7 Under Attic(Unvented) HALL 20 Blown 28 ft2 0.1 Woad _ 8 Under Attic(Unvented) AHU CLST 20 Blown 12 ft' 0.1 Wood _ 9 Under Attic(Unvented) UTILITY 20 Blown 70 ft' 0.1 Wood _ 10 Under Attic(Unvented) STAIRS UP 20 Blown 42 ft2 0.1 Wood _ 11 Under Attic(Unvented) BATH 20 Blown 72 ft2 0.1 Wood _ 12 Under Attic(Unvented) CLST2 20 Blown 6112 0.1 Wood _ 13 Under Attic(Unvented) CLST3 20 Blown 6ft2 0.1 Wood 14 Under Attic(Unvented) BEDROOM 20 Blown 198 ft2 0.1 Wood _ 15 Under Attic(Unvented) BEDROOM 20 Blown 198 ft2 0.1 Wood 16 Under Attic(Unvented) DEN 20 Blown 307 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 N Exterior Concrete Block - Ext Insul KITCHEN 4.1 22 0 10 0 220.0 ft2 0 0 0.2 0 _ 2 W Exterior Concrete Block- Ext Insul KITCHEN 4.1 10 0 10 0 100.0 ft2 0 0 0.2 0 _ 3 N Exterior Concrete Block- Ext InsWIVING ROO 4.1 5 0 10 0 50.0 ft2 0 0 0.2 0 _ 4 S Exterior Concrete Block- Ext InsJIIVING ROO 4.1 22 0 10 0 220.0 ft2 0 0 0.2 0 _ 5 W Exterior Concrete Block- Ext InsWIVING ROO 4.1 24 0 10 0 240.0 ft2 0 0 0.2 0 _ 6 E Exterior Concrete Block- Ext Ins51EDROOM 1 4.1 8 0 10 0 80.0 ft2 0 0 0.2 0 _ 7 S Exterior Concrete Block- Ext Ins51EDROOM 1 4.1 14 0 10 0 140.0 ft2 0 0 0.2 0 _ 8 E Exterior Concrete Block- Ext Insul WIC 1 4.1 5 0 10 0 50.0 ft2 0 0 0.2 0 _ 9 S Exterior Concrete Block- Ext Insul WIC 1 4.1 6 0 10 0 60.0 ft2 0 0 0.2 0 _ 10 E Exterior Concrete Block - Ext Insul BATH 1 4.1 7 0 10 0 70.0 ft2 0 0 0.2 0 _ 11 E Exterior Concrete Block - Ext Insul CLST 4.1 3 0 10 0 30.0 ft2 0 0 0.2 0 _ 12 N Exterior Concrete Block- Ext Insul HALL 4.1 5 0 10 0 50.0 ft2 0 0 0.2 0 _ 13 E Exterior Concrete Block - Ext Insul HALL 4.1 4 0 10 0 40.0 ft2 0 0 0.2 0 14 N Exterior Concrete Block - Ext Insul UTILITY 4.1 10 0 10 0 100.0 ft2 0 0 0.2 0 _ 15 E Exterior Concrete Block - EM Insul UTILITY 4.1 7 0 10 0 70.0 ft2 0 0 0.2 0 _ 16 E Exterior Frame - Wood STAIRS UP 13 7 0 10 0 70.0 ft2 0 0.25 0.2 0 _ 17 W Exterior Frame - Wood BATH 2 13 8 0 10 0 80.0 ft2 0 0.25 0.2 0 _ 18 N Exterior Frame - Wood BEDROOM 2 13 20 0 10 0 200.0 ft2 0 0.25 0.2 0 _ 19 W Exterior Frame- Wood BEDROOM 2 13 8 0 10 0 80.0 ft2 0 0.25 0.2 0 20 S Exterior Frame- Wood BEDROOM 3 13 20 0 10 0 200.0 ft2 0 0.25 0.2 0 21 W Exterior Frame - Wood BEDROOM 3 13 8 0 10 0 80.0 ft2 0 0.25 0.2 0 22 N Exterior Frame -Wood DEN 13 15 0 10 0 150.0 ft2 0 0.25 0.2 0 _ 23 E Exterior Frame- Wood DEN 13 17 0 10 0 170.0 ft2 0 0.25 0.2 0 24 S Exterior Frame -Wood DEN 13 15 0 10 0 150.0 ft2 0 0.25 0.6 0 11/28/2018 11:09 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed onenlation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Single Yes OA 0.25 N 20.0 ft- 1 ft 0 in 1 ft4 in None None 2 N 1 Vinyl Low-E Single Yes 0.45 0.3 N 24.0 ft- 1 ft 0 in 1 ft 4 in None None 3 N 3 Vinyl Low-E Single Yes OA 0.25 N 18.0 ft- 1 ft 0 in 1 ft 4 in None None _ 4 S 4 Vinyl Low-E Single Yes OA 0.25 N 36.0 ft2 1 ft 0 in 1 ft 4 in None None _ 5 S 4 Vinyl Low-E Single Yes 0.45 0.3 N 48.0 ft- 1 ft 0 in 1 It in None None _ 6 W 5 Vinyl Low-E Single Yes OA 0.25 N 36.0 ft2 1 ft 0 in 1 ft 4 in None None _ 7 E 6 Vinyl Lcw-E Single Yes OA 0.25 N 18.0 ft2 1 ft 0 in 1 ft 4 in None None _ 8 S 7 Vinyl Low-E Single Yes OA 0.25 N 36.0 ft- 1 ft 0 in 1 ft 4 in None None 9 E 13 Vinyl Low-E Single Yes 0.45 0.3 N 24.0 ft2 1 ft 0 in 1 ft 4 in None None 10 E 15 Vinyl Low-E Single Yes OA 0.25 N 16.0 ft2 1 ft 0 in 1 ft 4 in None None 11 W 17 Vinyl Low-E Single Yes OA 0.25 N 20.0 ft2 1 ft 0 in 1 ft 4 in None None _ 12 N 18 Vinyl Low-E Single Yes 0.4 0.25 N 36.0 ft- 1 ft 0 in 1 ft 4 in None None 13 S 20 Vinyl Low-E Single Yes 0.4 0.25 N 36.0 ft2 1 ft 0 in 1 ft 4 in None None _ 14 N 22 Vinyl Low-E Single Yes OA 0.25 N 18.0 ft2 1 ft 0 in 1 ft4 in None None _ 15 E 23 Vinyl Low-E Single Yes OA 0.25 N 36.0 ft' 1 ft 0 in 1 ft 4 in None None 16 S 24 Vinyl Low-E Single Yes OA 0.25 N 18.0 ft2 1 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000423 2285.7 125A8 235.98 .3224 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None C0P:1 17 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None CORI 17 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 17.9 kBtu/hr 537 cfm 0.8 1 sys#1 2 Central Unit/ Split SEER: 16 17.9 kBtu/hr 537 cfm 0.8 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None UTILITY 0.95 50 gal 62.3 gal 120 deg None 11/28/2018 11:09 AM EnwgyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS _ / — Supply— — Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heal Cool 1 Attic 6 125 fP Attic 13 ft2 Default Leakage AHU CLST (Default) c(Default) c 1 1 2 Attic 6 125 ft2 Attic 13 ft2 Default Leakage Attic (Default) c(Default) c 2 2 TEMPERATURES Programable Thermostat: N Ceiling Fans:Cooling Jan Feb Heating ent ng Jan fIX,I Mar Apr Ma € May IX� Jun [ ]Jul [X] ] Aug X� 4 ] Sep rj)C,) Novr[X,� Dec Feb [X] Apr May Jun [ 1 Jul E 1 Aug [ 1 Sep Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 LIVING ROOM Default(8 lbs/sq.ft. ft2 It 0.3 BEDROOM 1 Default(8 lbs/sq.ft. ft2 It 0.3 WIC Default(8 lbs/sq.ft. ft2 ft 0.3 BATH 1 Default(8 lbs/sq.ft. ft2 ft 0.3 CLST Default(81bs/sq.ft. ft2 ft 0.3 HALL Default(8 lbs/sq.ft. ft2 ft 0.3 AHU CLST Default(81bs/sq.ft. ft2 It 0.3 UTILITY Default(81bs/sq.ft. ft2 It 0.3 STAIRS UP Default(81bs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 lbs/sq.fL ft2 it 0.3 CLST 2 Default(81bs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2 It 0.3 BEDROOM 3 Default B lbs/s .ft. ft2 It 0.3 DEN Name: Rating Compant: Date:_ Ir • 11128/2018 11:09 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: REVORD RESIDENCE Builder Name: TC CUSTOM HOMES Street: GERMANY CANAL ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: U Owner: Jurisdiction: ST LUCIE COUNTY w Design Location: FL, Fort Pierce C.) COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in an soffit Y dropped 9/ PP ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with.a Where provided instead of floor insulation, insulation Class 1 vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electricallphone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 11/28/201811:10 AM EnergyGaugeD USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 35.8 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2062 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.411 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.261 c) Area 7c. 440.0 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 19.0 9c. 10A1. 13.0 10A2. 4.1 14. Heating system: Capacity 34.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 10131. 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 20.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be ins ailed (or/exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed sed o installed code compliant features. Builder Signature: AZ4 Date: Address of New Home: GERMANY CANAL ROAD City/FL Zip: FORT PIERCE. FL 111281201811:09:56 AM EnergyGauge@ USA 6.0.02- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 + wrightsoft• Project Summary AHU1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-46W96 Email: OUICKCALCS@AOLCOM Project• Job: Date: SEPr. 25, 2018 By: For. REVORD RESIDENCE, TC CUSTOM HOMES GERMANY CANAL ROAD, FORT PIERCE, FL SCANNED BY Notes. St. Lucie County Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TO 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16195 Btuh Structure 13358 Btuh Ducts 2551 Btuh Ducts 0 Btuh Central vent (O cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 18747 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 12690 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2319 Btuh Ducts 950 Btuh Heatingg Coolingg Central vent (0 cfm) 0 Btuh Area (ft2) 1233 1233 Equipment latent load 3269 Btuh Volume (fta) 12330 12330 Air changes/hour 0.31 0.15 Equipment total load 15959 Btuh Equiv. AVF (cfm) 63 32 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6018B1 AHRI ref Coil TEM6AOB24H21++TDR AHRI ref 7567552 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 5.3 kW Sensible cooling 12530 Btuh Heating output 18157 Btuh Latent cooling 5370 Btuh Temperature rise 28 OF Total cooling 17900 Btuh Actual airflow 597 cfm Actual airflow 597 cfm Air flow factor 0.032 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible. heat ratio 0.80 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -I{i- wrightsoft- 21118-Sep-2511:00:20 RightSuileO Universal 2017 17.0.08 RSU08101 Page 1 ACCkEADocumnelslWtlghtsoft HVAC1REVORD RESIDENCE.mp Cale, -MJ8 Front Door hoes: S Summary wrightsofY Project ry Date Date: SEPT.25, 2018 AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 772-466-6799 Farc 772-066-6796 Erred: OUICKCALCS@AOL.COM Project• • For. REVORD RESIDENCE, TC CUSTOM HOMES GERMANY CANAL ROAD, FORT PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grllb Heating Summary Sensible Cooling Equipment Load Sizing Structure 8157 Btuh Structure 11579 Btuh Ducts 2080 Btuh Ducts 2084 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 10236 Btuh Use manufacturer's data n Ratelswing multiplier 0.95 Infiltration Equipment sensible load 12981 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2024 Btuh Ducts 775 Btuh Heatingg Cooling Central vent (0 cfm) 0 Btuh Area (ft-) 829 829 Equipment latent load 2799 Btuh Volume (ft3) 8710 8710 Air changesthour 0.34 0.17 Equipment total load 15780 Btuh Equiv. AVF (cfm) 49 25 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6018131 AHRI ref Coil TEM6AOB24H21++TDR AHRI ref 7567552 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 3.1 kW Sensible cooling 12530 Btuh Heating output 10599 Btuh Latent cooling 5370 Btuh Temperature rise 16 OF Total cooling 17900 Btuh Actual airflow 597 cfm Actual airflow 597• cfm Air flow factor 0.058 cfm1Btuh Air flow factor 0.044 cfmlBtuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed Wrl htsof - 2018Sep-2511:00:20 9 RightSuiteG Universal 2017 17.0.08 RSUDS101 Page 2 ACCN E1DocurmetsiWrightsoft FNAC1REVORD RESIDENCE.rup Cale=MJ8 Front Door faces: S wrightsoft• Right-J® Worksheet AHU1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE. FL 34946 Phone: 772-466-6799 Fa c 772466-6796 Email: QUICKCALCS@AOL.COM Job: Date: SEPT. 25, 2018 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area AHU 1 1S20 ft 10.0 It 1233.0 ft2 LIVING ROOM 51.0 ft 10.0 ft heat/cool 1.0 x 629.0 ft 629.0 ft2 Ty Construction number U-wilue (Btt"ft-F) Or HTM (BtutVft2) Area (ft-) or perimeter (ft) Load (Btuh) Area (ft-) or perimeter (ft) Load (Btuh) Heat I Cool Grass WP/S Heat I Cool Gross WPIS Heat I Cwl 6 11 y! JIFF--------GGGG 13A-0ocs 2 glazing, Gr low 2 glazing,'dr law-e 2 glazing,. clr lava. 2 glazing, clr lave 13A-0ocs 2 glazing, Gr lc ✓ e 2 glazing, clr lcw-e 2 glazing, clr Iowa 2 glazing, clr lower 2glazig, 2 glazing, co- lave 2 glazing, clr low-e 2 glazing, dr lower 13A4ocs 2 glazing, dr lc u e 2 alazlna. clr low-e 16431tad 22A-tph 0.143 0.400 0.400 0.400 0.400 0.400 0A00 0.400 0.400 0.143 0.400 0.4D0 0.400 0.400 0.143 0.400 0.400 0.032 1.358 n n n n a a a a a a s s s s w w w - - 4.00 .0 11.20 11.20 11.20 4.00 11.20 1.20 11.20 11.00 4.00 1.20 11.20 11.20 4.00 0.00 11.2D 0.90 38.02 219 0.00 8.12 8.12 8.12 2.19 9.55 19.55 19.65 1219 210 8.12 8.12 8.12 2.19 0.00 19.55 224 0.00 42 0 20 18 24 340 6 18 18 24 420 0 72 48 340 0 36 446 1233 35 b � 0 0 ' 0 280 0 0 0 0 300 0 72 48 304 0 0 446 152 143 0 0 224 202- 269 1120 0 202 269 269 1200 6 806 538 1217 0 403 400 5780 783 0 162 146 195 610 0 352 469 659 650 0 585 390 665 0 704 999 0 50 0 0 18 0 0 0 0 0 0 220 0 36 48 240 0 36 0 629 32 0 0 0 0 0 0 0 0 0 130 0 36 48 204 0 0 0 51 12 0 0 0 202 0 0 0 0 0 0 540 0 403 538 817 0 403 0 1939 70 0 0 146 0 0 0 0 0 0 290 0 292 390 446 0 704 0 0 I�IF--------GGGG 11/ Vy II--GG C F 6 c)AM excursion 0 1 -2 Envelope loss/gain 14251 7037 4974 2344 12 a) Infiltration b) Roan ventilation 1944 0 521 0 - 652 0 175 0 13 Internal gains: Occupants Q 230 Appliances/other 0 0 58M 0 0 1500 Subtotal(Iines 6to 13) 16195 13358 5627 4019 14 15 Less extemal load Less transfer Redistribution . - Subtotal Duct loads 16% 0% 0 0 0 16195 2551 0 0 0 13358 0 16% 0% 0 0 443 6070 956 0 0 368 4388 0 Trial roan load Air required (clm) 18747 597 130 ss7 7026 224 4388 196 �,, 41- wrightsoft- 2018Sep-2511:00:20 ZFK RightSuile® Universal 2017 17.0.08 RSU08101 Page 1 E:\Dacumnets\Wdghtsoft HVAC\REVORDRESIDENCE.rup Calc=MJ8 Fmnt Doorfaces: S wrightsoft' Right-M Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466.6799 Fax 772466-6796 Email: OUICKCALCS a@ OL.COM Job: Date: SEPT. 25, 2018 By: 1 2 3 4 5 Room name Emosed wan Room height Room dimensions Room area BEDROOM 1 220 ft 10.0 ft heat/cool %o x 13.0 ft 1820 fN WIC 1 11.0 ft 10.0 ft heat/cool 1.0 x 25.0 ft 25.0 ft? Ty Construction number U-value (BtulVftz°F) Or HTM (Btuh/ft') Area (119 or perimeter (a) Load (Btuh) Ama (ft.) a perimeter (ft) Load (Btuh) Heat I Cocl Gross WP/S Heat I Cool Gross WP/S Heat Cod 6 11 13A-0acs 2 glazing, cir lave 2 glazing, cir luxe 2 glazing, clr lowe. 2 glazing, dr lov;e 13A-0acs 2 glazing, dr Iw 2 glazing, clr lave 2 glazing, dr lave 2 glazing, cir lave 13A4ccs� 2 glazing, cir lone 2 glazing, cir love' 2 glazing, cir lo" 13A4ocs 2 glazing, cir lave 2 plazinp, clr lave 16A-30ad 22A-tph 0.143 0.400 0.400 0A00 0.400 0.400 0.400 0.400 0.400 0.400 0.143 0.400 0.400 0.400 0.143 0.400 0.400 0.032 1.358 n- n n n n a e. a a e- s a s s w w w - - 4.00 0.00 11.20 11.20 11.20 4.00 1.20 11.20 11.20 11.20 4.00 0.00 11.20 11.20 4.00 0.00 11.20 0.90 38.02 219 0.00 8.12 8.12 8.12 219 19.55 9.55 19.55 19.55 219 0.00 8.12 8.12 2-19 0.00 19.55 z24 0.00 0 0 0 0. 0 80 0 0 18 0 140 0 36 0 0 0 0 24 182 0 0 0 0 0 62 0 .0 0 0 104 0 36 0 0 0 0 24 22 0 0 0 0 0 240 0 0 202 0 416 0 403 0 0 0 0 22 837 0 0 0 0 0 130 0 0 352 0 228 0 292 0 0 0 0 54 0 0 0 0 0 0 50 0 0 0 0 60 0 0 0 0 0 0 25 25 0 0 0 0 0 50 0 0 0 0 60 0 0 0 0 0 0 25 11 0 0 0 0 0 200 0 0 0 0 240 0 0 0 0 0 0 22 418 0 0 0 0 0 100 0 0 0 0 131 0 0 0 0 0 0 56 0 Yy I�IF---------GGGG VI/ {L�- fGG y/ ��GG C F 6 c)AM mursion -103 -15 Envelope loss/gain 2127 958 1 881 282 12 a) Infiltration b) Room ventilation 281 0 75 0 141 0 3B 0 13 internal gains: Occupants @ 230 Appliances/other 0 0 1200 0 0 0 Subtotal (lines 6 to 13) 2409 2234 1022 320 14 15 Less lindemal load Less transfer Redistribution Subtotal Dud loads 16% 0% 0 0 0 2409 379 0 0 0 2234 0 160A 0% 0 0 0 1022 161 0 0 0 320 0 Tot roomload Air regained (cfm) 2788 89 2234 100 1183 38 320 14 wrightsofY 2018Sep-2511:00:20 RightSuile® Universal 201717.0.08 RSUDS101 Page 2 iiC�A EADocumneta Wdghtsoft HVAMREVORD RESIDENCE.n o Calc = MJ8 Front Door faces: S + wrightsoft^ Right4@ Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466.6796 Email: OUICKCALCS@AOL.COM Job: Date: SEPT. 25, 2018 By: 1 Room name BATH 1 CLST 2 3 4 5 Exposed wall Room height Room dmensions Room area 7.0 it 10.0 ft heat/000l 7.0 x 7.0 ft 49.0 ft2 3.0 It 10.0 it beat/Cool 3.0 x 3.0 ft 9.0 ft2 Ty Conshuction number U-value (BtuhtflVF) Or HTM (Btuwft9 Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross M/P/S Heat Cool Gross WPIS Heat Cool 6 11 y/ 2gluins 2 glazing, or low+e 2 glazing, clr love 2 gluing, or lower 2 glazing, or low-e 13A-4= 2 glazing, or lows 2 glazing, dr low-e 2 glazing, dr low-e 2 glazing, dr lower ,13A4ocs 2 glazing, clr lower 2 glazing, drlow� 2 glazing, clr low-e 13A4ocs 2 glazing, dr lcw� 2 glazinq, dr low-e 16A-30ad 0.400 0.143 0.400 0.400 0.400 0.143 0.400 0.400 0.400 0.400 0.400 0.400 0.400 0.400 0.143 0.400 0.400 0.032 n n n n n a a a a a s s s s w w w - 0.00 4.00 11.20 11.20 11.20 4.00 0.00 11.20 11.20 11.20 4.00 1.20 1L20 11.20 4.00 0.00 11.20 0.90 2.19 0.00 8.12 . 8.12: 8.12 Z19 0.00 19.55 19.65 19.55 219 0.00 8.12 8.12 2.19 0.00 19.55 224 0' 0 0 -0 0 70 0 0 0 0 0 0 0 - 0 0 0 0 49 0 0 0 0 0 70 0 0 0 0 0 0- 0 0 0 0 0 49 0 0 0 0 0 290 0 0 0 0 0 0 0 0 0 0 0 44 0, 0 0 0 0 153 0 0 0 0 0 0 0 0 0 0 0 110 0 0 0 0 0 30 0 0 0 0 0 0, 0 0 0 0 0 9 0 0 0 0 0 30 0 0 0 0 0 0 0. 0 0 0 0 9 0 0 0 0 0 120 0 0 0 0 0 0 0 0 0 0 0 8 0 0 0 0 0 66 0 0 0 0 0 0 0 0 0 0 0 20 IIFF--------GGGG y/ y/ II----GG C F 22A-tph 1.358 - 38.02 0.00 49 7 266 0 9 3 114 0 6 c)AEDex ursim -26 -4 Ernelope Ices/gain 690 237 _ 242 82 12 a) InfiItraticn 90 24 38 10 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 300 0 0 0 Subtotal Pines 6 to 13) 680 561 281 92 14 15 Less etdemal load Less transfer Redistribution Subtotal Duct loads 16% 0% 0 646 1=6 0A1149 209 16%0% 0 0 -281 0 0 0 0 -92 0 0 Total rcorn load Alr required (cfm) 1535 49 0 0 0 0 - Wrr9h!'OiC RightSuite® Universal 201717.0.08 RSU08101 A eAE:\DacunmetslWdghtsoft HVAC\REVORDRESIDENCE.mp Calc=MJ8 Front Doorfaces: 2018-Sep.25 11:00:20 Page 3 wrightsoft Right-J@ Worksheet Job: AHu IDate: SEPT. 25, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 7724666799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1 Room name HALL AHU CLST 2 3 FEposed wall Roam height 9.0 it 10.0 ft heallocol 0 It 10.0 it heaucod 4 5 Room dimensions Room area 7.0 x 4.0 ft 28.0 ft' 4.0 x 3.0 it 12.0 ft' Ty Construction U-wlue Or HTM Area (fP) Load Area (W) Load number (BtuWft-F) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WPlS Heat Cool Gross WP/S Heat Cod fi 11 41 13A-0ocs 2.glazing. cir lmw 2 glazing, dr Iowa 2 glazing, clr Iowa 2 glazing,.clr Iowa 13AAcos 2 glazing, cir lava 2 glazing, clr lawn 2 glazing, clr Iowa 2 glazing, dr Iowa 13A4ocs 2 glazing, clr Iowa 2 glazing, dr Iowa 2 glazing,,dr Iowa 13AAocs 2 glazing, clr Iowa 2 glazing, clr Iowa 16A-30ad 0.400 0.400 0.400 0.400 0.400 0.143 0.400 0.400 0.400 0.400 0.143 0.400 0.400 0.400 0.143 0.400 0.400 0.032 n n n� n in a a a a a s s- s s w w w - 0.00 1.20 11.20 11.20 11.20 4.00 0.00 11.20 11.20 11.20 4.00 0.00 11.20 11.20 4.00 0.00 11.20 0.90 0.00 8.00 8.12 &12 8.12 2.19 0.00 19.55 19.55 19.55 219 0.00 8.12 8.12. 2.19 0.00 19.55 2.24 0 0 0 0 0 40 0 0 0 -24 0 0 0 0 0 0 0 28 0 0 0 0 0 16 0 0 0 0 0 0 0 0 0 0 0 28 200 0 0 0 0 64 0 0 0 269 0 0 0 0 0 0 0 25 100 0 0 0 0 35 0 0 0 469 0 0 0 0 0 0 0 63' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 11 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 27 IIIL---------CGGG Vy I-G It--GG C F 22AAph 1.358 - 38.02 0.00 28 9 342 0 12 0 0 0 6 c)AED excursion 217 -1 Envelope lossfgain 900 893 1 11 26 12 a) Infiltration 115 31 0 0 b) Room %entilatim 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancestother 1 0 0 Subtotal (lines 6 to 13) 1015 924 11 26 Less external load 0 0 0 0 Less hansfer 0 0 0 0 Redistribution -1015 -924 .11 -26 14 Subtotal 0 0 0 0 15 Duct loads 161/6 0% 0 0 16% 0% 0 0 Total room load 0 0 0 0 Air required (cfm) 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. #- wrightSofY 2018-Sep-25 11:00:20 RighlSuilepJ Universal 201717.0.08 RSU08101 Page 4 �� EADocunnnetslWrighlsoft HVAC1REVORD RESIDENCE.mp Calc = MJB Front Door faces: S wrightsoft' Right-J@ Worksheet Job: AHU 1 Date: SEPT. 25, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fa,c 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Roam name UTILRY KITCHEN 2 Exposed wall 17.0 It 320 It 3 Room height 10.0 it heat/cool 10.0 It heaticool 4 Room dimensions 10.0 x 7.0 1t 1.0 x 229.0 fit 5 Room area 70.0 ft' 229.0 ft- Ty Construction U-value Or HTM Area (ft.) Load Area (ft' Load number (BtuWft-F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross I WPIS Heat Cool Gross NIPIS Heat I Cool 6 4y 13A-0ocs 0.400 n 4.00 219 100 10a 40a 210 22a 170 700 380 2 glazing, or lax 0.400 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr Iowa 0.400 n 11.20 8:12 0 0 0 0 20 0 224 162 III---rfGG' 2 glazing, or Iowa 0.400 n 11.20 8.12 0 0 0 0 0 0 0 0 11 2 glazing, clr Iowa 0.400 n 11.20 8.12 0 0 0 0 24 0 269 195 W 0.400 a 219 70 59 210 110 0 0 0 0 �L��rGGG' 2 glazing, or Iowa 2glazi g, 0,400 a 0.00 0 0 0 0 0 0 0 2 glazing, clr Iowa 0,400 a 1.20 11.20 9.55 19.55 6 16 0 179 313 0 0 0 0 2 glazing, clr Iowa 0.4D0 a 11.20 19.55 0 0 0 0 0 0 0 0 2 glazing, clr Iowa 0.400 a 11.20 19.55 0 0 0 0 0 0 0 0 Vj/ 130.-0ocs 0.400 s 4.00 219 0 0 0 0' 0 0 0 0 2 glazing, clr lave 0.400 5 0.00 0 0 0 0 0 0 0 0 7glazing, drlow� 0.400 s 1.20 11.20 &12 0 0 0 0 0 0' 0 0 ��I-(GG` 2 glazing,clr lava 0.400 s 11.20 8.12 0 0 0 0 0 0 0 0 W, 13A-4ocs 0.143 w 4.00 219 0 0 0 0 100 100 400 219 IL -(G' 2 glazing, cIr lore 0.400 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr lcw a 0.400 w 11.20 19.55 0 0 0 0 0 0 0 0 C 16AJOad 0.032 - 0.90 224 70 70 63 167 229 229 - 2D5 613 F 22Atph 1.358 - 38.02 0.00 70 17 646 0 229 32 1217 0 61 c)AED excursion 127 -193 Envelope losstgain 1505 934 3020 1281 12 a) Induration 217 5B 409 110 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2800 Subtotal(lines 6to 13) 1722 992 3429 4191 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 214 78 3 7 14 Subtotal 1937 1070 3432 4198 15 Duct loads 16% 0%1 305 0 16°6 0%1 541 0 TAotarel mload 2242 10780 3973 4198 e(cfm) 71 4 127 188 Calculations approved hyACCA to meet all requirements of Manual J 8th Ed. .4C�A # wrightsofr 2018Sep-25 11:00:20 RighlSuile® Universal 201717.0.08 RSU08101 Page 5 EADocumnets\Wrightsoft HVAC\REVORD RESIDENCE.mp Cale =MA Front Door faces: S wrightsoft° Right-J® Worksheet Job: AHU 2 Date: SEPT. 26, 2016 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 77246"799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name AHU 2 STARS UP 2 3 Exposed wall Room height 118.0 ft 10.5 ft 7.0 It 20.0 ft heat/cool 4 5 Room dimensions Room area 829.0 ft' 6.0 x 7.0 ft 42.0 ft' Ty Construction number U-value (Btuhlfti-F) Or H- M (Bb"fN) Area (ft') a perimeter (ft) Load (Btuh) Area (fly or perimeter (ft) Load (Btuh) Heat I Cool Gross WP/S Heat Cool Gross NIPIS Heal Cool 6 11 W 2gluins 2 glazing, Gr Iowa 2 glazing, cir Iowa 2 glazing, cir Iowa 2 glazing, cir low -a 2 glazing, cir lowe 2gluins 2 glazing, cir Iowa 2 glazing, clr Iowa 2 glazing, cir Iowa 13A-0acs 2 glazing, clrlowa 2 glazing; cir low-e 2 glazing, cir Iow-e 13AAccs 2 glazing, cir Iowa 2 glazing. cir Iowa 16A-30ad 0.143 0.400 0.400 0.400 0.400 0.400 0.400 0.400 0.400 0.400 0.143 0.400 0.400 0.400 0.143 0.400 0.400 0.032 n n n n n a a a a a s s s s w w w - 4.20 14.20 0.00 0.00 0.00 4.20 10.20 0.00 0.00 0.00 4.00 11.20 0.00 0.00 4.00 11.20 0.00 0.90 219 12.19 0.00 0.00 0.00 219 30.00 0.00 0.00 0.00 219 11.24 0.00 0.00 2.19 30.02 0.00 224 354 54 0 0 0 36 236 0 0 0 350 54 0 0 240 20 0 829 290 0 0 0 0 200 0 0 0 0 296 54 0 0 220 0 0 829 185 1605 0 0 0 817 403 0 0 0 1185 605 0 0 881 224 0 743 648 607 0 0 0 081 1081 0 0 0 648 607 0 0 481 600 0 1867 0 0 0 0 0 70 0 0 0 0 0 0 0 0 0 0 0 42 0 0 0 0 0 70 0 0 0 0 0 0 0 0 0 0 0 42 0 0 0 0 0 280 0 0 0 0 0 0 0 0 0 0 0 38 0 0 0 0 0 153 0 0 0 0 0 0 0 0 0 0 0 - 94 II{F-------GGGG . 4y IIII--------GGGG y/ Vjl L�-GG C F 22A4ph 1.358 - 0.00 0.00 42 0 0 0 42 0 0 0 6 c)AED excursion 0 -7 Envelope loss/gain 6648 6975 318 240 12 a) Infiltration 1509 404 90 24 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 Appliances/other 0 0 4200 0 0 0 Subtotal (lines 6 to 13) 8167 11579 407 264 Less extemal load 0 0 0 0 14 15 Less transfer Redistribution Subtotal Duct loads 251/6 18% 0 0 8157 2080 0 0 11679 2084 25% 25%1 0 -407 0 0 0 -264 0 0 Total room Iced Al,required (cfm) 10236 697 13661 597 0 0 0 0 4- wrights ft- 2018-Sep-25 11:00:20 RighlSuite® Universal 2017 17.0.08 RSU08101 Page 6 EADocumnelslWrighlsoft HVAC%REVORD RESIDENCE.rup Cale =MJ8 Front Door faces: S wrightsoft' RighW@ Worksheet Job• AHU 2 Date: SEPT. 25, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phona: 772-4665799 Fax 772-466-6796 Email: OUICKCALCS AOL.COM 1 Room name BATH 2 CLST 2 2 3 5posed wall Room height 8.0 ft 10.0 it heat/cool 0 ft 10.0 If heat/cool 4 5 Room dimensions Room area 1.0 x 72.0 H 720 ft' 3.0 x 2.0 ft 6.0 ft' Ty Construction ll-value Or HTM Area (111 Load Area (fly Load number (Btuh/ft-F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S I Heat Cool 6 11 13A-4ccs 2 glazing, cir Iowa 2 glazing, cir Iowa 2 glazing, cir Iowa 2 glazing, cir Iowa 13A-0ocs 2 glazing, cir Iowa 2 glazing, cir Iowa 2 glazing, cir Iowa 2 glazing, clr Iowa 13A-0ocs 2 glazing, cir low-e 2 glazing, clrlava 2 glazing, cir Iowa 13FMocs 2 glazing, clr Iowa 2 glazing, cir Iowa 16A-30ad 0.143 0.400 0.400 0.400- 0.400 0.143 0.400 0.400 0.400 0.400 0.400 0.400 0.400 0.400 0.143 0.400 0.400 0,032 n n n n n a a a a a s s s s w w w - 4.00 11.20 0.00 0.00 0.00 4.00 11.20 0.00 0.00 0.00 4.20 10.00 0.00 0.00 4.00 11.20 0.00 0.90 219 11.24 0.00 0.00 0.00 2.19 30.02 0.00 0.00 0.00 219 10.00 0.00 0.00 2.19 30.02 0.00 224 0 0 0 0 0 0 0 0 0 0 0 0 0 0 80 20 0 72 0 0 0 0 0 0 0 0 0 0 0 0 0 0 60 0 0 72 0 0 0 0 0 0 0 0 0 0 0 0 0 0 240 224 0 65 0 0 0 0 0 0 0 0 0 0 0 0 -0 0 131 600 0 161 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 0 0 0 0 0 0 0 0 0 '0 0 0 0 0 0 0 0 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13 VIl IN IL-CG C F 22A-tph 1.358 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 254 0 Envelope loss/gain 529 1147 5 13 12 a) Infiltration 102 27 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 1 0 0 0 0 0 Subtotal Qines 6 to 13) 631 1175 5 13 Less eldemal load 0 0 0 0 14 1151 Less transfer Redistribution _ Subtotal Duct loads 259/6 180/6 0 3 634 162 0 7 1182 213 25% 18% 0 5 .0 0 0 -13 0 0 Total room load Air required (cfm) 796 46 1395 st 0 o 0 0 'OFE' wright5oft' 2018Sep-2511:00:20 RightSuite® Universal 2017 17.0.08 RSU08101 Page 7 .9C�A E:1DocunnetslWrightsoft HVAC\REVORD RESIDENCE.mp Cale =MJ8 Front Door faces: S wrighksoR Right Worksheet Job: AHU 2 Date: SEPT. 25, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORTPIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1 Room name CLST 3 BEDROOM 2 2 Exposed wall 0 It 28.0 It 3 Room height 10.0 it heat(cool 10.0 ft heat/ccol 4 Room crmensions 3.0 x 20 ft 1.0 x 198.0 ft 5 Room area 6.0 ft2 198.0 ft2 Ty Construction U-wlue Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ftz°F) (Btuh/ft') a perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross WP/S Heat Cool 6 Vy 13A-0acs 0.400 n 4.20 2.24 0 0 0 0 236 160 359 2.glazing, Gr low-e 0.400 n 10.00 10.00 0 0 0 0 36 0 400 403 405 400 2 glazing, Gr lows 0.400 n 0.00 0.00 0 0 0 0 0 0 0 0 ILF�------.GGGG 2 glazing, clr lave 0.400 n 0.00 0.00 0' 0 0 0 0 0 0 0 11 2 glazing, clr lavc 0.400 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-0ocs 0. a 4.0 2.0 0 0 0 0 0 0 0 0 2 glazing, clr lowc 0.400400 a 1.200 30.2 00 0 0 0 0 0 0 0 0 2 glazing, clr Iowc 0.400 a 0 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr lowe 0.400 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr lows 0.143 a 0.00 0 0 0 0 0 0 0 0 W - 0.400 5 4.00 0 0 0 0 0 0 0 0 2 glazing, clr lwr-e 2glazi g, 0.400 s 11.20 1.20 1.24 10.00 0 0. 0 0 0 0 0 0 ILL-----GGG 2 glazing, clr laic 0:400 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr lave 0.400 s 0.00 0.00 0 0 0 0 0 0. 0 0 ILI13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 80 80 320 175 2 glazing, clr lcw-e 0.400 w 11.20 30.02 0 0 0 0 0 0 0 0 2 glazing. clr lows 0.400 w 0.00 0.00 0 0 0 0 0 0 0 0 C '16ASOad 0.032 - 0.90 Z24 6 6 5 13 198 198 177 444 F 22A-tph 1.358 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 0 -64 Envelope loss/gain 5 13 1558 1318 12 a) Inliftration 0 0 358 96 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Appliances/other 1 0 850 Subtotal (Iines 6 to 13) 5 13 1916 2264 Less e#emal load 0 0 0 0 Less bander 0 0 0 0 Redistribution -5 -13 4 9 14 Subtotal 0 0 1920 2273 15 Duct loads 25% 18% 0 0 25% 18% 489 409 Tglal room load 0 0 2409 2682 Air required (cfm) 0 0 140 117 A - � wrightsoft- 2018Sep-2511:00:20 RightSude® Universal 201717.0.08 RSUG8101 Page 8 EADocumnels\Wrightsoft WAC\REVORD RESIDENCE.rup Cale = MA Front Door faces: S I wrightsoft RighW@ Worksheet Job: AHU 2 Date: SEPT. 25, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fine 772466.6796 Email: QUICKCALCS@AOL.COM 1 Roam name BEDROOM 3 DEN 2 3 Eposed wall Room height 28.0 it 10.0 It heat/cool 47.0 It 10.0 R heal/coal 4 5 Room dimensions Room area 1.0 x 198.0 It 1980 ft' 1.0 x 307.0 If 307.0 ft' Ty I Construction number U-%dlue (Btuh/ftMF) Or HTM (BtuNft2) Area (ft') or Perimeter (ft) Load (Btuh) Area (115 or perimeter (ft) Load (Btuh) Heat I Coal Gross WP/S Heat Cool Gross N/P/S Heat Cacl 6 11 2 glaiing, dr Iowa 2g;adns 2 glazing, dr Iowa 2 glazing, clr Iowa 2 glazing, clr Iowa 2gl fats 2 glazing, clr low-e 2 glazing, clr lore 2 glazing, cir Iava 2 glazing, dr Iowa 13A46cs 2glazirg, dr Im-e 2 glazing, dr lave 2.glazing, clr Iowa 13A-0ocs 2 glazing, clr low-e 2 glazing, dr Iowa 16A-30ad 0.400 0.400 0.400 0.400 0.400 0.400 0.400 0.400 0.400 0.400 0.143 0.400 0.400 0.400 0.143 0.400 0.400 0.032 n n n n n a a a a a a s s s w w w - 4.20 10.00 0.00 0.00 0.00 4.20 11.20 0.00 0.00 0.00 4.00 11.20 0.00 0.00 4.00 11.20 0.00 0.90 1.24 11.00 0.00 0.00 0.00 0.02 30.00 0.00 0.00 0.00 2.19 11.24 0.00 0.00 2.19 30.02 0.00 Z24 0 0 0 0 0 0 0 0 0 0 200 36 0 0 80 0 0 198 0 0 0 0 0 0 0 0 0 0 164 36 0 0 BO 0 0 198 0 0 0 0 0 0 0 0 0 0 657 403 0 0 320 0 0 177 0 0 0 0 0 0 0 0 0 0 359 405 0 0 175 0 0 444 18 118 0 0 0 136 36 0 0 0 150 18 0 0 0 0 0 307 132 0 0 0 0 130 0 0 0 0 132 18 0 0 0 0 0 307 200 202 0 0 0 537 403 0 0 0 529 202 0 0 0 0 0 275 289 202 02 0 0 0 293 1081 0 0 0 289 202 0 0 0 0 0 688 -G 4y V�I F--G 1y ��GG C F 22A-tph 1.358 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -24 -158 Envelope loss/gain 1558 1358 2675 2886 12 a) hfiltraticn b) Room ventilation 358 0 96 0 601 0 161 0 13 Internal gains: Occupants Q 230 Appliances/other 0 0 850 0 0 2500 Subtotal Qines 6to 13) 1916 2304 3276 6547 Less eAwd load 0 0 0 0 14 15 Less transfer Redistribution Subtotal Duct loads 25A 18% 0 4 1920 489 0 9 2313 416 25% 189% 0 407 3684 939 0 264 5811 1046 Total mom load Alr required (cfm) 2409 140 27 0 119 4623 270 6857 300 wrightsoTt- 2018Sep-25 11:00:20 RightSulteO Universal 201717.0.08 RSU08101 Page 9 .9C�h EADocumnets WrightsoB HVACIREVORD RESIDENCE.mp Cats, =MJS Front Door faces: S - - wrightsoft Duct System Summary AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A66-6799 Falc 772-466.6796 Email: OUICKCALCSQAOL.COM For. REVORD RESIDENCE, TC CUSTOM HOMES GERMANY CANAL ROAD, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 597 cfm Job: Date: SEPT. 26, 2018 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 597 cfm 144 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matt Actual Ln (ft) Fig.Egv Ln (ft) Trunk BATH C 1149 49 51 1.000 6.0 Ox0 VIFx 8.6 95.0 BEDROOM 1 C 2234 89 100 1.000 7.0 OxO VIFX 21.2 115.0 st1 KITCHEN C 2099 63 94 1.000 7.0 Ox0 VIFX 21.9 115.0 st2 KITCHEN -A c 2099 63 94 1.000 7.0 Ox 0 VIFx 10.8 115.0 st2 LIVING ROOM h 3513 112 98 1.000 7.0 Ox0 VIFx 23.7 115.0 st1 LIVING ROOM -A h 3513 1121 98 1.000 7.0 OxO VIFx 22.0 115.0 st1 UTILITY h 2242 71 48 1.000 6.0 Ox0 VIFX 11.7 115.0 st2 WIC h 1163 38 14 1.000 4.0 OxO VIFx 29.1 115.0 st1 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st1 Peak AVF 350 310 1.000 793 9.0 0 x 0 VinlFlx st2 Peak AVF 198 235 1.000 674 8.0 0 x 0 VinlFlx Return Branch Detail Table Name Grill Size (in) Htg (cfm) Cig (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (In) H x W (in) Stud/Joist Opening (in) Duct Mat] Trunk rb3 OxO 597 597 0 0 0 0 Ox 0 VIFx wri htsoft° 2018Sep-2511:00:21 a. 9 RlghtSuite® Universal 2017 17.0.08 RSU08101 Page 1 04CCk5ADocumnelslWrightso@ HVACIREVORD RESIDENCE.rup Dole =MJB Front Door faces:S wrightsoft Duct System Summary AHU2 QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE. FL 34946 Phona: 772-466-6799 Farc 772-466-6796 Email: OUICKCALCS@AOL.COM r-roject intormation For. REVORD RESIDENCE, TC CUSTOM HOMES GERMANY CANAL ROAD, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 597 cfm Job: Date: SEPT. 25, 2018 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 10.500 in H2O 1.000 in/100ft 597 cfm 130 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (1n) (in) Mall Ln (ft) Ln (ft) Trunk BATH c 1395 46 61 1.000 6.0 Ox0 VIFx 11.1 115.0 st4 BEDROOM h 2409 141 117 1.000 7.0 Ox0 VIFx 9.1 115.0 st4 BEDROOM h 2409 141 119 1.000 7.0 Ox0 VIFx 9.1 115.0 st4 DEN c 3429 135 160 1.000 8.0 Ox 0 VIFx 13.0 115.0 st3 DEN -A C 3429 135 150 1.000 8.0 Ox0 VIFx 15.0 115.0 st3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st4 Peak AVF 327 297 1.000 741 9.0 0 x 0 VinlFlx st3 Peak AVF 270 300 1.000 678 9.0 0 x 0 VinlFlx Return Branch Detail Table Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb2 Ox 0 1 597 597 0 0 0 0 Ox 0 VIFx 2018-Sep-25 11;00:21 wrightsoft' RlghlSuite® Universal 201717.0.08 RSU08101 Page 2 14CCk E1Documnels%W6ghtsoft WAC%REVORD RESIDENCE.rup Cale =MJ8 Front Door faces: S * wrightsoft Project Summary AHU1 QUICK CALCS, INC. SCANNED BY St. Lucie County 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM • mect Information For. REVORD RESIDENCE, TC CUSTOM HOMES GERMANY CANAL ROAD, FORT PIERCE, FL Notes: Job: Date: SEPT. 25, 2018 By: Design Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16195 Btuh Structure 13358 Btuh Ducts 2551 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 18747 Btuh Use manufacturer's data n Ratelswing multiplier 0.95 Infiltration Equipment sensible load 12690 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2319 Btuh Ducts 950 Btuh Heatingg Coolingg Central vent 0 cfm) 0 Btuh Area (ft2) 1233 1233 Equipment la Ent load 3269 Btuh Volume (fta) 12330 12330 Airchanges/hour 0.31 0.15 Equipment total load 15959 Btuh Equiv. AVF (cfm) 63 32 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6018B1 AHRI ref Coil TEM6AOB24H21++TDR AHRI ref 7567552 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 5.3 kW Sensible cooling 12530 Btuh Heating output 18157 Btuh Latent cooling 5370 Btuh Temperature rise 28 OF Total cooling 17900 Btuh Actual air flow 597 cfm Actual air flow 597 cfm Air flow factor 0.032 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.80 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. I t wrightsoft• 2018sep-2511:00:20 RightSuite® Universal 201717.0.08 RSU08101 Page 1 EADocumnetslWrightsoft HVAC%REVORD RESIDENCE.rup Colo =MJ8 Front Door faces: S + wrightsofts Project Summary AHU2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS AOL.COM Project For. REVORD RESIDENCE, TC CUSTOM HOMES GERMANY CANAL ROAD, FORT PIERCE, FL Notes: Job: Date: SEPT. 25, 2018 By: Design Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 8157 Btuh Structure 11579 Btuh Ducts 2080 Btuh Ducts 2084 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 10236 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 12981 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2024 Btuh Ducts 775 Btuh Area Heatingg Cooling Central vent (0 cfm) 0 Btuh (ft2) 829 829 Equipment latent load 2799 Btuh Volume (ft3) 8710 8710 Air changes/hour 0.34 0.17 Equipment total load 15780 Btuh Equiv. AVF (cfm) 49 25 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trans Trade Trade TRANE Model Cond 4TTR6018B1 AHRI ref Coil TEM6AOB24H21++TDR AHRI ref 7567552 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 3.1 kW Sensible cooling 12530 Btuh Heating output 10599 Btuh Latent cooling 5370 Btuh Temperature rise 16 OF Total cooling 17900 Btuh Actual air flow 597 cfm Actual air flow 597 cfm Air flow factor 0.058 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed - WrIghYSOfC 2018-Sep-2511:00:20 RighlSuite® Universal 2017 17.0.08 RSU08101 Page 2 -4CCp`EADocumnetslWoghtsoft NVAC1REVORD RESIDENCE.rup Calc=MJ8 Front Door faces:5 +wrightsoft Right-J@Worksheet Job: AHU 1 Date: SEPT. 25, 2018 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name 5posed wall Room height Room dimensions Room area AHU 1 152.0 ft 10.0 It 1233.0 ft- LIVING ROOM 51.0 It 10.0 It heaticool 1.0 x 629.0 H 629.0 It' Ty Construction number U-value (Btuh/fti°F) Or HTM (Btuh/fN) Area (W) or perimeter (ft) Load (Btuh) Area (it') or perimeter (ft) Load (Btuh) Heat I Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 11 13A-0ocs 2 glazing, clr lowe 2 glazing, oIr Iowa 2 glazing, ctr lowe 291azing-clrloac__ 13A-0ocs 13A-4o s clr loura 2 glazing, clr Icv-e 2 glazing, clr lowe 2 glazing, clr Iowa -0ocs � 13A- -'-- 2 glazing,clr Iowa 2 glazing, clr low-e 2 glazing. clr lav7.-_. 13A-0acs 2glazing, cirlowa 2 glazing, cir lows_ 16A30atl_^._ 22A-tph i-_a_ _0:143 0.400 0.400 0.4D0 _ -,--0.400 0.400 0.143 0.400 0.400 0.400 0.143 0.400 0.400 ___0.400 0.400 0.400 , __0.400 „_0.0.32 1.358 n n n n --n_ a a a a a s s s _a,_ w w w -._ -- - -4.00 0.00 11.20 11.20 ___11.20 4.00 4.00 11.20 11.20 11.20 4.00 0.00 11.20 _ 11,20 4.00 1L20 1.20 -__0.90 38.02 2.19 0.00 &12 8.12 -.8.12 0.00 2.10 19.55 19.55 _ 19.55 2:19 0.00 8.12 __8.12 2.00 _ 19.55 9.55 _ _2.24 0.00 420 0 20 18 24 340 0 16 18 24 --� 420 0 72 ___48 340 6 --_ __ 36 e_._ 446 1233 -_.._� 0 0 0 __ 0 280 0 0 0 0 --' --300' 0 72 48 300 0 _ _ 0 _446 152 1438 0 224 202 �._269 1120 0 179 202 _ 269 - 1201 0 WE 538 1210 0 _ 403 _. w 5780 ___ _783 0 162 146 ___195 610 0 313 352 469 _ -� '656 0 585 _ _390 660 0 _ 704 �._ 999 0 _.-_50 0 0 18 _-. _0.._- 0 0 0 0 0 -----220 0 36 48 y 240 6 _36 _-0 629 ._ _-32 0 0 0 0 0 0 0 0 0 -----136 0 36 _. __ 48 200 0 0 _ -o - 51 ___ _ 128 0 0 202 _.__p 0 0 0 0 0 --545 0 403 -_ _538 810 0 403 _-0 1939 ____70 0 0 146 ___0 0 0 0 0 0 ------298 0 292 _ __390 440 0 704 -__0 . 0 tt/ 1--G �L-GC Vj! Il----GG A_- F 61 c)AED excursion 0 -2 Envelope loss/gain 14251 7037 4974 2344 12 a) Infiltration b) Room ventilation 1944 0 521 01 1 652 0 175 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 5800 0 0 1500 Subtotal (lines 6to 13) 16195 13358 5627 4019 14 15 Less e#emal load Less lraasfer Redistribution Subtotal Duct loads 16% 0% 0 0 0 16195 Ml 0 0 0 133% 0 169/6 0% 0 0 443 6070 956 0 0 368 4388 0 Total room load Air required (cfm) 18747 597 13358 597 7026 224 4388 196 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wright aft- RighlSuiteO Unhersal 201717.0.08 RSU08101 2018-Sep-25 11:000::20 E:\Documnels\WdghtsoftWACIREVORDRESIDENCE.mp Calc=MJ8 Front Doorfaces: S wrightsofr Right-M Worksheet Job: AHU 1 Date: SEPT. 25, 2018 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 2 3 4 5 Room name Etyosed wall Room height Room dimensions Room area BEDROOM 1 22.0 ft 10.0 ft heat/cool 14.0 x 13.0 It 182-0 ft2 WIC 1 11.0 ft 10.0 it heat/cool 1.0 x 25.0 ft 25.0 ft2 Ty Construction number U-value (Btut✓ftk°F) Or HTM (Btuh/ft2) Area (W) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat I Cool Gross NIP/S Heat Cool Gross N/P/S Heal Cool 6 11 yy!! I---G 13A;46F--_. _ . _ 2 glazing, clr lovve 2 glazing, clr low-e 2 glazing, clr love 2glazing-clr-low;e_. 13A4acs 2 glazing, clr lowe 2 glazing, clr lowe 2 glazing, clr love 2 glazing, Gwa r Io --- 13A-0ocs 2 glazing; clr lave 2 glazing, clr Iowa 2 glazing. clr.lave__ 13A4ocs 2 glazing, clr lave 2 glazing, Gr loxes__ 16A-30ad 22A olh __ _..0.143 0.400 0.400 0.400 0.400 0.400 0.400 0.400 0.400 ~�0.143 CF143 0.400 0.400 ^0.400 0.143 0.400 _ _0.400 _ _0.032 1.358 n n n n _n_ a a a a a s s s _s_ w w w_ =_ - 4.00 0.00 11.20 11.20 _11.20 4.00 11.20 1.20 11.20 11.20 4.00 0.00 11.20 _-11.20 4.00 0.00 11.20 _-0.90 38_02 2.19 0.00 8.12 8.12 �8.12 2.00 19.55 9.55 19.55 19.55 2.19 0.00 8.12 __ &12 2.19 0.00 19.55 - 2-24 0.00 - ---0 0 a 0 _-_0 80 0 0 18 0 - --140 0 36 -___.0 0 0 0 -.�24 192 __ ___0 0 0 0 0 _- 0 0 0 0 __0 248 0 0 20 0 0 � � 416 0 403 _0 0 0 0 _ _22 837 ---_--0 0 0 0 - --0 130 0 0 352 0 228 0 292 _0 0 0 0 '-� 54 0 _ __-.._ -0--0-0 0 0 0 0 0 0 ___0 50 0 0 0 0 -60 0 0 0 0 0 0 '25 11 0 0 0 --- -0 0 0 0 IIL-------tGG _ . 62 0 0 0 0 -__-104 0 36 ___0 50 0 0 0 0 ---60 0 0 0 0 0 __ 0 _-25 25 -0 200 0 0 0 0 -'240 0 0 0 0 0 0 22 _ 418 t-_0 100 0 0 0 0 --- -131 0 0 _._0 0 0 0 56 0 W�--G �G �C 1�I I-G F, _ _0 0 0 0 _ _ 24 22 6 c)AED excursion _103 -15 Envelope loss/gain 2127 958 881 282 12 a) Inliltration b) Room ventilation 281 0 75 0 141 01 38 0 13 Internal gains: Occupants Q 230 Applianceslother 0 0 1200 0 0 0 Subtotal (lines 6 to 13) 2409 2234 1022 320 14 15 Less wdemal load Less transfer Redistribution Subtotal Duct loads 16% 0% 0 0 0 2409 379 0 0 0 2234 0 16% 0% 0 0 0 1022 161 0 0 0 320 0 Total room load Air required (cfm) 1 2788 89 2234 100 1 1183 38 320 14 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed -Ark- wrightsof , RightSuiteO Universal 201717.0.06 RSU08101 2018-Sep-25 11:00:20 E:\DmumetsNWdghtsoftHVAC\REVORDRESIDENCE.mp Calc=MJB Front Doorfaces: S g wrightsoft, Right-M Worksheet Job: AHU 1 Date: SEPT. 25, 2018 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Emil: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Eposed wall Room height Room dimensions Room area BATH 1 7.0 it 10.0 It heat/cool 7.0 x 7.0 it 49.0 ft2 CLST 3.0 it 10.0 1t heat/cool 3.0 x 3.0 it 9.0 W Ty Constriction number U-value (Btuh/ft;'F) Or HTM (Btuh/ft� Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat I Cool Gross NIP/S Heat Cool Gross NIP/S Heat Cool 6 11 W13A-4ocs__.._ _ ..__-0:143 2 glazing, clr law-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr.lav-e__ 2gimins 2 glazing, clr lows 2 glazing, clr lower 2 glazing, clr low-e 2 glazing, clr Icw-e _, 13A-flocs 2 glazing,-cir lmv-e 2 glazing, or low-e 2glaang,clr.low--e_ _ 13A4ocs 2 glazing, or low-e 2 glazing clr lower .16A-3Dad_ _p 22A-tph___ 0.400 0.4D0 0.400 _0.4D0 0.400 0.400 0.400 0.400 0.400 .__ __ _ 0.143 0.400 0.400 ___0.400_s__71.20___8.12 0.143 0.400 ___ 0.400 __ 0.032 LM n n n n __n_ a a a a a s..`__ '� s s s w w w _-- _ 4.00 0.00 11.20 11.20 11.20 0.00 0.00 11.20 11.20 11.20 4.00 0.00 11.20 4.00 0.00 11.20 -- _0.90 _ 38.02 --219..-___0____._D..__.___D_____D______0._-_0-_-0_.__.__0 0.00 8.12 8.12 - 8.12 219 19.55 9.55 19.55 19.55 _ � � 2.19 0.00 8.12 2.19 0.00 19.65 _,2.24 __0_00 0 0 0 _ . 0 70 0 0 0 0 - -__0 0 0 -._.0.___0_0 0 0 0 . 49 49 0 0 0 0 0 0 0 ---0 280 0 0 0 0 - _ _ _. _0 0 0 0 0 0 _ 44 266 0 0 0 _ __0 153 0 0 0 0 .. ___ _0 0 0 0 0 0 1110 0 0 0 0 __- 0 30 0 0 0 0 . _ � 0 0 0 0 _0 a 9 9 0 0 0 __0 30 0 0 0 0 .__ _0 0 0 0 0 0 _�`_9 __3 0 0 0 0 0 0 0 ------ 0 66 0 0 0 0 _ . _ _._.0 0 0 0 0 0 ___ 20 -----0- _L--G y/ �FL�--GCCC 70 0 0 0 0 _ ---0 0 0 0 0 0 _ _49 7 __._ 120 0 0 0 0 �___ .0 0 0 0 0 0 _ - _ _8 F __--_114 6 c)AED excursion -26 -4 Envelope loss/gain 590 237 242 82 12 a) Infiltration b) Room ventilation 90 0 24 0 38 0 10 0 13 Internal gains: Occupants @ 230 Applianceaother 0 0 300 0 0 6 Subtotal(Iines 6to 13) 680 561 281 92 14 15 Less eMemal load Less transfer Redistribution Subtotal Duct loads 16% 0% 0 0 646 1326 209 0 0 588 1149 0 160/0 0% 0 0 -281 0 0 0 0 -92 0 0 Total room load Air required (cfm) 1 1535 491 1141 1 51, 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. h -11,14- wrightsoft- RighlSuite® Universal 2017 17.0.08 RSUD8101 2018-Sep-25 1 Page 3 E:\Documnets\Wrightsoft HVAC\REVORO RESIDENCE.rup Celc = MJ8 Front Door faces: S wrightsoft• Right-MMorksheet Job: AHU 1 Date: SEPT. 25, 2018 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 FaX 772466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name E:yosed wall Room height Room dimensions Room area HALL 9.0 ft 10.0 it heaticool 7.0 x 4.0 ft 28.0 W AHU CLST 0 ft 10.0 ft heat/cool 4.0 x 3.0 ft 120 ft2 Ty Construction number U-value (Btuh/ftc'F) Or HTM (Btuh/ft2) Area (ftq a perimeter (ft) Load (Btuh) Area (1112) a perimeter (ft) Load (Btuh) Heat Cool Gross N/PIS Heat Cool Gross NIP/S Heat Cool 6 11 _ - _ ._ 13A-0oc__- s __. 2glazing, clr lose 2 glazing, clr lone 2 glazing, clr lowe 2glazing,.clrlax_e__ . 13A-0ocs 2 glazing, or love 2 glazing, or lowe 2 glazing, cir lowe 2 glazing, clr low-e 13A-0o'cs _ 2 glazing, clr lowe 2 glazing, clr Im-e 2glazing,.c1r1ow-e___..�.�0.400_s-__11.20_8.12 13A-4ocs 2glazing, or low-e 2 glazinq, dr lower _ 16P-30ad. -` . 0.143 0.400 0.400 0.400 __0.400 0.400 0.400 0.400 0.400 0.400 __._-(143 0.400 0.400 0.143 0.400 _ ,-L0.400 _0032 __ 1,358 n n n n _.n_ a a a a a 's7 s s w w w_ -.. 4.00 0.00 11.20 11.20 _ 11.20 4.00 11.20 1.20 11.20 11.20 _ 4.00 0.00 11.20 4.00 0.00 11.20 =-0.90 38.02 _ -. 2.19 0.00 8.12 8.12 _ 8.12 0.00 19.55 9.55 19.55 _ 19.55 , 2. 1-9 0.00 8.12 Z19 0.00 19.55 _2.24 0.00 __ ___50 0 0 0 ___0 40 0 0 0 24 -.-- _0 0 0 __.__0_ 0 0 _ _ _ 0 _ _ -28 28 _ . __50 0 0 0 .___O 16 0 0 0 0 - 0 0 0 _ _0 0 0 0 --28 _ _ 9 -_ 200 0 0 0 __0 64 0 0 0 269 0 0 0 _0 0 0 , 0 _ __25 342 ___ _709 0 0 0 0 ._a0 0 0 0 _0 0 0 0 0 0 -'0 0 0 0 0 0 0 0 0 0 __�0 0 0 0___0 0 0 0 __,_12 0 -. _ 0 0 0 0 0 0 0 0 0 0 -_-0 0 0 0 0 0 A_77 0 _--... 0 0 0 0 -LG y/ 35 0 0 0 469 __--0 0 0 0 0 _ 0 _ _ 63 ---0-. ^0 0 0 0 0 _ 0 -0 0 0 0 0 -� 0 f �_ 27 0 IIII--------lGGG W�---G ---.0 0 0 _0 0 0 _ 0 ,___ 12 12 �� Vy . _ . F_ _ - _ _ _ 22Atph ___ - -_ _ - -_ _ _ -- -- -- 6 c) AFJ) excursion 217 -1 Envelope loss/gain 900 893 11 26 12 a) Infiltration b) Room ventilation 115 0 31 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6to 13) 1015 924 11 26 14 15 Less a demal lead Less transfer Redistribution Subtotal Duct loads 160/6 0% 0 0 -1016 0 0 0 0 -924 0 0 161/6 0% 0 0 -11 0 0 0 0 -26 0 0 Total room load Air required (cfm) 0 0 0 0 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -114+ wrigill RlghtSuileO Universal 201717.0.08 RSU08101 2018-Seµ2511:00:20 Page 4 E:\Dacumnets\Wrlghtsofl HVACIREVORD RESIDENCE.mp Cale = MJfi Front Door faces: S wrightsoft Right-M Worksheet Job: AHU 1 Date: SEPT. 25, 2018 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1 2 3 4 5 Room name Eposed wall Room height Room dimensions Room area UTILTfY 17.0 It 10.0 It heat/cool 10.0 x 7.0 it 70.0 ft' WCHEN 32.0 it 10.0 It heat/cwl 1.0 x 229.0 It 229.0 It. Ty Construction number U-value (Btuwfti°F) Or HTM (Btuh/ft-) Area (M or perimeter (ft) Load (Btuh) Area (w) or perimeter (ft) Load (Btuh) Heat I Cool Gross WP/S Heat Cod Gross N/P/S Heat Cool 6 11 13A46E-- '----_-"0343 2 glazing, air low-e 2 glazing, clr lower 2 glazing, or lower 2 glazing. clr lavc 13A4ocs 2 glazing, clr Irnvs 2 glazing, or lc w e 2 glazing, clr lower 2 glazing, clr lcwe 13Aoc -0s 2 glazing, clr low -a 2 glazing, clr lave 2glazing,clrl=w .__ 13A4ocs 2glazing, clr low-e 24Zrn'g, clr I=-e._ 16A30ad__ MLAph___ 0.400 0.400 0.400 _ _ _0.400 0.143 0.400 0,400 0.4D0 0.4DO 0343 0.400 0.400 __ _0.400 0.143 0.400 0.400 _--0.032 _. 1.358 n n n n __n_ a a a a a s s s s. w w w_ - _ - 4.OD-7219--_. 0.00 11.20 11.20 -11.20 4.00 .00 11.20 11.20 11.20 4.00 0.00 11.20 _11.20._ 4.00 0.00 _ 11.20 __0.90 38.02 0.00 8.12 8.12 __8.12 2-19 219 19.55 19.55 19.55 219 0.00 8.12 8.12__- 219 0.00 19.55 .-2.24. 0.00 100 0 0 0 _ _. __0 70 0 16 0 0 -�_ _0 0 0 0_ 0 0 ____ 0 _70 70 -100 0 0 0 ___ 0 54 0 0 0 0 � --D 0 0 .. -0 0 0 __ 0 - __70 17 400 0 0 0 _ ---0 21 0 0 179 0 0 -219 0 0 0 ____0 11 0 0 313 0 0 -_ ____0,� 0 0 0 0 0 0 �157 _ 0 -220---178 0 20 0 ._ _24 0 0 0 0 0 _-0 0 0 0_____0___0 100 0 _ _ __ _0 _229 229 0 0 0 ------0 0 0 0 0 0 _-0 0 0 100 0 __ _ 0 ___..229 32 -705---385 0 224 0 __-__269 0 0 0 0 0 . __-_0 0 0 400 0 __-__ 0 �205 1217 0 162 0 _.A 795 0 0 0 0 0 -_.__0 0 0 _ 0 219 0 0 0 -===G _ Vfl -F- 0 0 0 -0 0 0 0 -__�63 _ 646 L----GG G _ _ YID--G F_ _127 fi 0)AED excursion -193 Erelope loss/gain 1505 934 3020 1281 12 a) Infiltration b) Room ventilation 217 0 58 0 409 0 110 0 13 Intemzl gains: Occupants Q 230 Appliances/other 0 0 0 0 0 2800 Subtotal Qines 6to 13) 1722 992 3429 4191 14 15 Less eAmnal load Less transfer Redistribution Subtotal Duct loads 16% 0% 0 0 214 1937 305 0 0 78 1070 0 16% 0% 0 0 3 3432 541 0 0 7 4198 0 Total rcom load Air required (cfm) 2242 71 1070 48 3973 127 4198 188 Calculations approved byACCA to meet all requirements of Manual J 8th Ed '0& wrights ft- RightSuite® Universal 201717.0.08 RSU08101 2018l 11:00:20 9 AME:\DoaumnetslWrighlsoft HVACIREVORD RESIDENCE.mp Colo = MJ8 Front Door (aces: S Page 5 wrightsoft° RighW@ Worksheet Job: AHU 2 Date: SEPT. 25, 2018 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-066-6799 Fat 772466.6796 Email: OUICKCALCS@AOL.COM 1 2 3 4 5 Room name Bposed wall Room height Room dimensions Room area AHU 2 118.0 It 10.5 ft 829.0 ft2 STAIRS UP 7.0 ft 20.0 ft heat/cool 6.0 x 7.0 ft 42-0 ft2 Ty Construction number U-value (Btuh/ft-F) Or HTM (Btulvft2) Area (ft2) or perimeter (ft) Load (8tuh) Area (ft.) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 444yyy 13A74ws - - - 2 glazing, clr Im-a 2 glazing, Ur low-e 2 glazing, cir lawe 2 glazing.cl[lowe_- 2 glazing, clr Iowa 2 gluing, 2 glazing, cIr lowe 2 glazing, cir Iowa 2 glazing, cir Iowa 1b3A-0ocs 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing. clr Iowa_ 13A-0acs 2 glazing, cir lows 2 glazing, clr low- _16A-30ad___ 22A-tph--_ - ` 0.143 0.400 0.400 0.400 _ 0.4D0 0.143 0.400 0.400 0.400 0.400 __- 0.143 0.400 0.400 _�0.400 0.143 0.400 �0.400 0.032 1.358 n n n n _n_ a a a a e - T s s _s_ w w w - _=,0.00 - 4.00 11.20 0.00 0.00 -0.00 4.00 14.20 0.00 0.00 0.00 _ 4.00 11.20 0.00 __0.00 4.00 11.20 0.00 �0.90 2.19 11.24 0.00 0.00 ___0.00 32.19 2.02 0.00 0.00 0.00 - 2.1.9 11.24 0.00 ___0.00 2.19 30.02 0.00 _ _224 0A0 - --360 54 0 0 ___0 36 236 0 0 0 __ _ _� 54 0 w.__. 0 240 20 0 _'-=829 _ 42 - - 296 0 0 0 _ _0 204 0 0 0 0 � _, 54 0 __ 0 220 0 0 ,�.829 _ -0 1185 605 0 0 _!0 817 403 0 0 0 ___1185'-_-648 605 0 _-_ _ 0 881 224 0_ _� _743 _ti 0 - --648 607 0 0 0 -'-- -0 0 0 0 _�0 70 0 0 0 0 ____0 0 0 0 0 0 0 - _42 i 42 -----0 0 0 0 __,_0 70 0 0 0 0 -_.__._0 0 0 _,. 0 0 0 __ 0 ___ _42 0 0 0 0 0 __.0 280 0 0 0 0 -__ _ U 0 0 0 0 0 0 0 1446 081 0 0 0 607 0 _0 481 600 0 . _1857 -_ 0 153 0 0 0 0 - -.0 0 0 0 0 0 �94 _ 0 VI/ II---- F 0 0 _ 0 38 0 6 .)Am excursion O_-_ _7 Envelope loss/gain 6648 6975 318 240 12 a) Infiltration b) Room ventilation 1509 0 404 0 90 0 24 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 4200 0 0 0 Subtotal (lines 6 to 13) 8157 11579 407 264 14 15 Less e#emal load Less transfer Redistribution Subtotal Duct loads 250% 18% 0 0 0 8157 2080 0 0 0 11579 2084 250% 25% 0 0 -407 0 0 0 0 -264 0 0 Total mom lead Air requiretl (c(m) 102M 597 13664 597 0 01 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed �� f wrights0- RightSuiteO Universal 201717.0.08 RSU08101 2018-Sep-2511:00:20 Page 6 E:\DoeumnelslWrightsaft HVAC1REVORD RESIDENCE.mp CeIc=MJB Front Door faces: 5 wrightsoft, Right-M Worksheet Job: AHU 2 Date: SEPT. 25, 2018 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1 2 3 4 5 Room name E)yosed wall Room height Room dimensions Room area BATH 2 8.0 it 10.0 It heat/cool 1.0 x 720 ft 72_0 ft2 CLST 2 0 It 10.0 ft heat/cool 3.0 x 20 ft 6.0 ft2 Ty Construction number U-value (BtuWftMF) Or HTM (Btuh/fP) Ana (ft2) or perimeter (ft) Load (Btuh) Area (ft2) a perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heal Cool s- 11 -13A_-0v 2 glazing, clr low-e 2 glazing. clr lows 2 glazing, clr lave 2 glazing, cIrlowc-. 13A-0ocs 2 glazing, clr low-e0.400400 2 glazing, clr Iowa 2 glazing, Ur low-e 2 glazing, clr low-e 13A-0s 2 glazing, clr Im-e 2 glazing, dr lowc 2glazing, clr,1=7e _ 13A-0ocs 2 glazing, clr lows 2 glazinu, clr laic 16A-30ad_-__ 2264ph _ 0.400 0.400 0.400 _0.400 0. 0.400 0.400 _ �0_400 0.143 0.400 0.400 _0.400 0.143 0.400 0_400 ^0.032 _ _ 1_358 n n n _n_ a a a a a 5 s s _s,_ w w w_ __ __ -4..0_0` 11.20 0.00 0.00 _0.00 4. 1.20 20 0.00 0 0.00 0.00 4.00 11.20 0.00 ___0.00 4.00 11.20 0.00 _ _ 0.90 0.00 -2.i9 11.24 0.00 0.00 _._0.00 2.0 30.2 00 0.00 0.00 0.00 -219 11.24 0.00 _ _0.00 219 30.02 0.00 -224 0.00 _....__p_ 0 0 0 __ _0 0 0 0 0 0 ___-.0 0 0- _0 80 20 _ 0 72 0 -_-.. p 0 0 0 ___0 0 0 0 0 0 -___0 0 0 0 60 0 0 .^_. 72�---65 0 _ -v0 0 0 0 _____0 0 0 0 0 0 . _____0 0 0 _ ___o 240 224 0 0 _ _ ..0 0 0 0 __0 0 0 0 0 0 ----.o 0 0 ......0 131 600 0 ----_161 0 _.�--_0 0 0 0 ____0 0 0 0 0 0 -__0. 0 0 0 _ _._.0 0 0 0 0 0 --0 0 0 ___0 0 0 0 _-6 0 0 0 _.,_._0 0 0 0 0 0 --.-0 0 0 ____0 0 0 0 0 0 0 0 -__0 0 0 0 0 -. 0 0 0 0 _L==G _ --0 0 0 _ _0 0 0 0 ---6 __ _ C F ! 0 0 0 0 -0 0 0, 6 c)AED excursion 254 0 Envelope loss/gain 529 1147 6 13 12 a) Infiltration b) Room ventilation 1 102 0 27 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 631 1175 5 13 14 15 Less wdemal load Less transfer Redistribution Subtotal Duct loads 25% 18% 0 0 3 634 162 0 0 7 1182 213 25% 180/0 0 0 -5 0 0 0 0 -13 0 0 Total mom load Air recUred(cfm) 796 46 1395 61 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A ' wrightsoft- RightSuite® Universal 2017 17.0.08 RSU08101 2018-Sep-25 11:00:20 E:1DocumnelslWdghtsoft WAC\REVORDRESIDENCE.mp Calc=MJS Front Doorfzces: S g + wrightsoft° RighW@ Worksheet AHU 2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fanc 772-466-6796 Emit: QUICKCALCS AOL.COM Job: Date: SEPT. 25, 2018 By: 1 2 3 4 5 Room name F)yosed wall Room height Roam dimensions Room area CLST 3 0 ft 10.0 It heat/cool 3.0 x 20 ft 6.0 ft- BEDROOM 2 28.0 ft 10.0 ft heal1cool 1.0 x 198.0 It 198.0 ft2 Ty Construction number U-value (Btuhfft�-F) Or HTM (BtulVft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cod Gross N/P/S Heat Cad Gross NIP/S Heat Cool 6 11 V/ jIG 13A-0acs___._V. _ 2 glazing, clr low¢ 2 glazing, dr lcvv a 2 glazing, dr low-e 2glazing. dr.Ime_ 2 gjazi s 2 glazing, dr Ime 2 glazing, dr Iowa 2 glazing, clr lowe 2 glazing, clr Iowa __ 13A-0ocs 2 glazing, clr lave 2 glazing, ilr lava 2 glazing, clr Iowa 13A-0acs 2 glazing, clr Iowa 2 glazing, dr low-e_ 16A-tph _.-_ 22Mph .__ _07143 0.400 0.400 0.400 -0.400 0.400 0.400 0.400 0.400 __0_400 0. 0.400 0.400 _0.400 0.143 0.400 _0.400 1.358 1.358 _ r n n n _n_ a a a a e s s a _s_ w w w_ _ _. = ._ _. 4.06 11.20 0.00 0.00 0.00 10.20 1.20 0.00 0.00 0.00 _143 4.00 11.20 0.D0 ,0.00 4.00 11.20 W 0.00 -0.90 0.00 '--239. 11.24 0.00 0.00 - __-0.00 219 30.00 0.00 0.00 0_00 .. -2. 19 11.24 0.00 _.._0.00 2.19 30.02 0.00 _2.24 0.00 _ ---0-- 0 0 0 _0 0 0 0 .�_._. _0 0 0 0 _ _--_0 0 0 0 --200 36 0 0 0 ..-164 0 0 0 0 - 657 403 0 0 -___359 405 0 0 - I--G IL---,--GG 1q/ __0 0 0 0 0 0 --0 0 0 ___0 0 0 _ _0 __ 6 _ __--0 0 0 0 0 0 -- _ _0 0 0 _ ____0 0 0 _ _0 6 _._0 0 0 0 0 0 __..-._0 0 0 _0 0 0 __ 0 _5 _---0. 0 0 0 0 0 _ _ -_.0 0 0 ____ 0 0 0 0 0 0 0 0 -_0 0 0 ___0 80 0 0 =198 0 0 0 0 0 ._-._._...0 0 0 _ 0 80 0 _ _ 0 _ _198 __0 0 0 0 0 0 _--"0 0 0 _ 0 320 0 _ _ 0 17Z .__.-_0 0 0 0 0 0 _.__._.__0 0 0 0 175 0 _ 0 ��444 ---0 -_ Vy Fri IL-�Gi V�J II----GG __ 'C__ F ._ ,43 _ 0---0 ----0-0-0 --0--0 _ '- --- ---' ^ - _ - 6 c)Am excursion p -64 Envelope loss/gain 5 13 1558 1318 12 a) Udiltration b) Room ventilation 0 0 0 0 358 0 96 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 01 0 0 fact Subtotal (lines 6to 13) 5 13 1916 2264 14 15 Less eternal load Less transfer Redistribution Subtotal Duct loads 255/6 18°% 0 0 5 0 0 0 0 -13 0 0 25% 18% 0 0 4 1920 489 0 0 9 2273 409 Total nnm load Air required (cfm) 0 0 0 0 2409 140 2682 117 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed A wrllghtsoR' RightSuite@ Universal 2017 17.0.08 RSU08101 2018-Sep-25 11:00:20 Page 8 E:1Documnets\Wdghtsoft HVAC\REVORD RESIDENCE.rvp Colo = MJB Front Door faces: S wrightsoft° RighW@ Worksheet Job: AHU 2 Date: SEPT. 25, 2018 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 2 3 4 5 Room name Elycsed wall Room height Room dimensions Room area BEDROOM 3 28.0 it 10.0 it heat/cool 1.0 x 198.0 it 198.0 W DEN 47.0 it 10.0 It heat(cool 1.0 x 307.0 ft 307.0 fP Ty Corutruction number U-value (BtuWft;°F) Or HTM (Btuhlft') Area (et or perimeter (ft) Load (Btuh) Area (W) or perimeter (ft) Load (Bluh) Heat I Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cod 6 11 13A-0ocs - _ ___ 2 glazing, clr lave 2 glazing, clr low-e 2 glazing, clr low- 2glazing, clr low-_, 13A-4ocs 2 glazing, clr low- 2 glazing, dr low- 2 glazing, dr low- 2glazing clr lower 13A-0acs 2 glazing clr low a 2 glazing, or lavk ''..2 glazing, crClovv_e- 13A-4= 2 glazing, clr low- 2dazing, clr low- ,16AS0ad _�... 22A-lph ---0143 0400 0400 0.400 .-0.400 0.143 0.400 0.400 0.400 0.400 -n - n n n _n_ a a a a a - s s -,a- w w w .._ 400 11.20 000 0.00 _w0.00 4.00 11.20 0.00 0.00 000 400 11.20 000 -,.0.00 4.00 11.20 000 .�,0.90 0.00 2.19 11.24 0.00 0.00 �0.00 2.19 30.02 0.00 0.00 0.00 ---219 11.24 0.00 _0.00 Z19 30.02 _ 0.00 _.._2.24 _ 0.09 0 0 0 0 ___0 0 0 0 0 0 W --200 36 0 0 --`___0 0 0 0 ___0 0 0 0 0 0 -i16l 36 0 0 ---.0 0 0 0 `._0 0 0 0 0 _ _ 0 _ _ 657 403 0 __^ 0 320 0 0 :�177 0 ...___ 0 0 0 0 _00 0 0 0 0 _ 0 --359 405 0 _ , 0 175 0 0 _ __-150 18 0 0 ' 132 0 0 0 0 -., 529 202 0 0 537 403 0 0 _ 0 _ '529 202 0 ---.--289 202 0 0 293 1081 0 0 _ 0 - 289 202 0 0 0 0 0 = =688 0 _L-G i .�..__ F 170 36 0 0 _ _ 0 150 18 0 ___0 0 0 0 �_ �307 0 134 0 0 0 0 -'--932 18 0 _0 0 0 __ 0 _ 307 0 0.143 0.400 0.400 _ 0.400 0.143 0.400 0.400 0.032 1.358 80 0 0 _ 198 __ 0 80 0 _ 0 _ -, 198 _ 0 _0 0 0 0 �_275 0 v-_ - �_ �444 0 - -__-- - -- 6 c)AFD excursion -24 158 Envelope loss/gain 1558 1358 2675 2886 12 a) Infillration b) Room ventilation 358 0 96 0 601 0 161 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 850 0 0 2500 Subtotal (lines 6 to 13) 1916 2301 3276 5547 14 1151 Less external load Less transfer Redistnbution Subtotal Duct loads 25% 18% 0 0 4 1920 489 0 0 9 2313 416 25% 18% 0 0 407 3684 939 0 0 264 5811 1046 Trial mom load Air required(cfm) 2409 140 2730 119 4623 270 6857 300 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wright aft- RightSuite® Universal 2017 17.0.08 RSU08101 2018SeP25 11:00:20 AWN 9 E:\DocumnetslWnghtsoR HVACIREVORD RESIDENCE.mp CaIc=MJB Front Door faces: S Page - wrightsoftDuct System Summary AHU1 QUICK CALCS, INC. 317 ST I.UCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OUICKCALCS@,AOL.COM For. REVORD RESIDENCE, TC CUSTOM HOMES GERMANY CANAL ROAD, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 597 cfm Job: Date: SEPT. 25, 2018 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 597 cfm 144 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Fig.Egv Ln (ft) Trunk BATH 1 c 1149 49 51 1.000 6.0 Ox 0 VIFx 8.6 95.0 BEDROOM 1 C 2234 89 100 1.000 7.0 OXO VIFx 21.2 115.0 SH KITCHEN C 2099 63 94 1.000 7.0 Ox0 VIFx 21.9 115.0 st2 KITCHEN -A c 2099 63 94 1.000 7.0 Ox0 VIFx 10.8 115.0 st2 LIVING ROOM h 3513 112 98 1.000 7.0 Ox0 VIFx 23.7 115.0 st1 LIVING ROOM -A h 3513 112 98 1.000 7.0 OxO VIFx 22.0 115.0 st1 UTILITY h 2242 71 48 1.000 6.0 Ox0 VIFx 11.7 115.0 st2 wlc1 h 1183 38 14 1.000 4.0 Ox0 VIFx 29.1 115.0 st1 Trunk Htg Clg Design Valor Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk SO Peak AVF 350 310 1.000 793 9.0 0 x 0 VinIFIX st2 Peak AVF 198 235 1,000 674 8.0 0 x 0 VinIFIX Return Branch Detail Table Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat] Trunk rb3 Ox0 1 597 597 0 0 0 0 Ox 0 VIFx 2018-Sep-25 1t00:21 rC wrightsofY RightSuite® Universal 2017 17.0.08 RSUG8101 Page 1 Al�l� EADocumnetslwnghtsoft HVACIREVORD RESIDENCE.rup Calc = MJ8 Front Door faces: S wrightsoft Duct System Summary AHU2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCSQAOL.COM For. REVORD RESIDENCE, TIC CUSTOM HOMES GERMANY CANAL ROAD, FORT PIERCE, FL Job: Date: SEPT. 25, 2018 By: Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply / return available pressure 0.500 / 0,500 in H2O 0.500 / 0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 597 cfm 597 cfm Total effective length (TEL) 130 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (Cfm) FIR (in) (in) Mail Ln (ft) Ln (ft) Trunk BATH 2 c 1395 46 61 1.000 6.0 Ox 0 VIFx 11.1 115.0 st4 BEDROOM h 2409 141 117 1.000 7.0 Ox0 VIFx 9.1 115.0 st4 BEDROOM h 2409 141 119 1.000 7.0 Ox0 VIFx 9.1 115.0 st4 DEN c 3429 135 150 1.000 8.0 Ox0 VIFx 13.0 115.0 st3 DEN -A c 3429 135 150 1.000 8.0 Ox0 VIFx 15.0 115.0 st3 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st4 Peak AVF 327 297 1.000 741 9.0 0 x 0 VinlFlx st3 Peak AVF 270 300 1.000 678 9.0 0 x 0 VinlFlx Return Branch Detail Table Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mail Trunk rb2 Ox0 597 597 0 0 0 0 Ox 0 VIFx C wrl htsoft` 2018-Sep-25 11:00:21 9 RighlSuite® Universal 201717.0.08 RSU08101 Page 2 ^"�^E:1DocumnetslWrighlsoft W=REVORD RESIDENCE.rup Cate =MJe Front Door faces: S