Loading...
HomeMy WebLinkAboutPLAN REVIEW RECORD2015INTERNATIONAL RESIDENTIAL CODE® Plan Review # 1810-0216 Date: 10/31/18 ° FOR ONE- AND TWO-FAMELY DWELLINGS Valuation: PLAN REVIEW RECORD Fee: JURISDICTION: _(City, County, Township, etc.)_ BUILDING LOCATION: 7810 GERMANY CANAL RD , PORT ST. LUCIE,FL 34987 - (Street address) - - BUILDING DESCRIPTION: SFR SCANNED - .- St. LUMP ('nij�±y =` REVIEWED BY: JWF :"Numerals indicated in parenthesis are applfcable code sections of the 2015 tntemational Residential Code (IRC). The, "pfan reviewaccomplished as indicated „ in this record is limited to those code sections specifically identified herein. This recored references commonly applicable code sections with due regard for '_, the amount and type of detailed Information which Is typically found on. construction documents for one- and two-family dwellings and townhouses. It ddes e not reference all code provisions which may be applicable to specific buildings. This record is designed to be used only by those wherein knowledgeable=" and capable of e)aercising'compatenl judgment in evaluating construction documents for code -compliance. CORRECTIONS LIST No. DESCRIPTION Code Section trademarkis the • For \� Copyright,115, International CodeReproduction -• ISBN 978-1-80983-671-9 ��- • • • 9 781609 8 61 15 IMEHNATIONAL CODE•••forms,IIII III IIIIIII III�IIIIIIIII CODE COUNCIL'PHONE• • tem, , , -1- No. CORRECTION LIST (cont'd.) DESCRIPTION Code Section -2- NOTE: Entries to this Plan Review Record that require afield check or Inspection of the installation must be coordinated with the inspection phase (13109) of the project. BUILDING PLANNING (Chapter 3) DESIGN CRITERIA [Table R301.2(1)] NA Parapets and construction Floor live load (Table R301.5) 40 psf (R302.2.2, R302.2.3) 20 Roof live load (Table R301.6) psf NA Two-family dwelling separation (R302.3) NA psf Ground snow load NA Dwelling unit penetrations (R302.4) 152 Ultimate design wind speed mph NA Dwelling/garage opening/penetration protec- tion (R302.5) Wind exposure category (R301.2.1.4)-C X Dwelling/garage fire separation (R302.6) High wind design criteria applicable NA Under -stair protection (R302.7) (R301.2.1.1) NA Seismic design category (SDC) X Wall and ceiling finishes (R302.9) [Figure R301.2(2)] NA X Flame spread index (13302.9.1) SDC C&D provisions (R301.2.2) NA X NEG Smoke -developed index (R302.9.2) Weathering Frost line depth NA NOP Testing (R302.9.3, R302.9.4) Termite area VH X Insulation (R302. f0) Decay area NA X Flame spread/smoke-developed Winter design temperature ENERGY CALCS (R302.10.1, R302.10.2) Ice barrier underlayment required NA NA Cellulose loose -fill and exposed attic Flood hazards X - NOT ON PLANS insulation (R302.10.3, R302.10.4) FIRE-RESISTANT CONSTRUCTION (R302) NOP Testing (R302.10.5) NA Exterior walls X Fireblocking (13302.11) (R302.1, Tables R302.1(1) and R302.1(2)] X Draftstopping (R302.12) NA Townhouse separation (R302.2) X Fire protection of floors (13302.13) NA Continuity and structural independence NA Combustible insulation clearance (R302.14) (R3022.1, R302.2.4) ROOM PLANNING REQUIREMENTS (R303 throuah R305) Use Area (fe) Width Ceiling height' Natural light* Natural ventilation' Living 70 T-0" 7'-0" 8%floor area 4%floor area Dining 70 T-0" 7'-0" 8%floor area 4%floor area Kitchen N.A. N.A. T-0" 8%floor area 4%floor area Bedroom 70 T-0" 7'-0" 8%floor area 4%floor area Bathroom N.A. N.A 6'-8" 3 square feet 1'/z square feet See Sections R303.1 & R303.3 for mechanical ventilation and artificial light and R303.4 for required whole -house mechanical ventilation. t 6'-8" min. at plumbing fixtures and for non -habitable basements. X Required heating (R303.9) SANITATION (R306 and R307) X Water closet X Lavatory X Tub or shower X Kitchen area with sink X Sanitary sewer (Chapter 30) X Private disposal (Appendix I) GLAZING (R308) Identification (R308.1) Louvered windows or jalousies (R308.2) Human impact loads/hazardous locations (R308.3, R308.4) Skylights and sloped glazing (R308.6) -3- BUILDING PLANNING (cont'd.) GARAGES AND CARPORTS (R309) NA Floor surface noncombustible; sloped floor (R309.1) open two sides; noncombustible ; sloped floor (R309.2) NA Automatic garage door opener (R309.4) NA Fire sprinklers (R309.5) EMERGENCY ESCAPE AND RESCUE OPENINGS (R310) X Where required (R310.1) Areas, height, width, operations (17310) Window wells (R310.2.3) Under decks and porches (R310.2.4) Bars, grilles, covers and screens (R310.4) MEANS OF EGRESS (11311) X General (R311.1) X Egress door (R311.2) X Landings at exterior doors (13311.3 - R311.3.3) Vertical egress (R311.4) Construction and attachment (R311.5) Hallways (R311.6) X Stairway width, headroom, vertical rise, walk - line (R311.71 - R311.7.4) NOP Stairway treads, risers profiles (R311.75 - R311.7.5.4) NOP Stairway landings and walking surfaces (R311.7.6, R311.77) NOP Handrails required (17311.78) Handrail height, continuity, grip -size (R311.7.8.1 - R311.78.4) Stairway illumination (R303.7, R311.7.9) Special stairways (R311.7.10) Ramp slope, landings, handrails (R311.8) GUARDS AND WINDOW PROTECTION (R312) Required for open -sided surfaces, stairs, ramps and landings > 30" above floor/ grade (11312.1.1) Height - 36" (R312.1.2) Opening limitations (R312.1.3) Window fall protection (R312.2) AUTOMATIC FIRE SPRINKLER SYSTEMS (R313) X Townhouses (R313.1) X One- and two-family d SMOKE ALARMS (R314) Referenced standards (17314.1) X Location and interconnection (R314.3, R314.4) Power source (R314.6) CARBON MONOXIDE ALARMS (R315) X New construction (R315.1, R315.2) Existing construction (R315.2.2) Referenced standard (R315.6) FOAM PLASTIC (R302.8, R316) Labeling (R316.2) Surface burning, thermal barrier, specific approval (R316.3 - R316.8) DECAY AND TERMITE PROTECTION (R317 and R318) X Protection required (Table R301.2(1), R3171, R318.1) Quality mark (R3172 and R318.1.1) SITE ADDRESS (R319) Address numbers (R319.1) ACCESSIBILITY (R320) NO Type B dwelling units applicable (13320.1) ELEVATORS/PLATFORM LIFTS (R321) Referenced standards (R321.1-R321.3) FLOOD -RESISTANT CONSTRUCTION (R322) General (R322.1) Hazard area and requirements (R301.2.4, R309.3, R322.2, R322.3) Design professional (R322.3.6) STORM SHELTERS (R323) General/referenced standard (13323.1) SOLAR ENERGY SYSTEMS (R324) System, installation, access (13324.2 - R324.7) MEZZANINES (R325) Area, egress, openness (R325.2 - R325.5) SWIMMING POOLS, SPAS AND HOT TUBS (R326) ISPSC (17326.1) -4- FOUNDATIONS (Chapter 4) MATERIALS (R402) Wood foundations (17402.1) Concrete, compressive strength (13402.2, R402.3) FOOTINGS (R403) x Soil -bearing value (R401.4, R403.1) x Footing width [Tables ,R403.1(1) - R403.1(3)] x Footing edge thickness; footing projection = 2" minimum, but <_ footing thickness (R403.1.1) Footings in SDC and D (R403.1.2 and R403.1.6.1) x Depth below (outside) grade = 12" minimum; but below frost line (R403.1.4, R403.1.4.1) Sill plate bolting in concrete/masonry =1/", di- ameter bolts, within 12" but not less than 7 bolt diameters from ends, 7" embedment (R403.1.6) Footings adjacent to slopes (R403.1.7) Frost -protected shallow foundations (R403.3) Footings for precast concrete foundations (R403.4) FOUNDATION/RETAINING WALLS (R404 - R406) Masonry foundation walls (R404.1.2) Wall height, unbalanced backfill, nominal thickness [Tables R404.1.1(1) - R404.1.1(4), R404.1.5.1] Reinforcement size and spacing (Tables R404.1.1(2) - R404.1.1(4)] Concrete foundation walls (R404.1.3) Wall height, unbalanced backfill, nominal thickness (Tables R404.1.2(1) - R404.1.2(8), R404.1.5.2] Horizontal and vertical reinforcement size and spacing (Tables R404.1.2(1) - R404.1.2(8), R404.1.3.2, R404.1.3.3.7] Stay -in -place forms (R404.1.3.3.6.1) SDC D provisions (R404.1.4) Height above finished grade (R404.1.6) Sill plate size (17404.3) Precast concrete foundation walls (R404.5) Drains required if habitable or usable spaces are below grade' (R405) Soil class (Table R405.1) Dampproofing if basements are below grade' (R406.1) Waterproofing if high water table' (R406.2) If uninhabitable, see Under -Floor Space (R408) COLUMNS (R407) Protection from decay or corrosion (R407.1 and R407.2) x Structural requirements (R407.3) Anchorage (R407.3) Wood columns (minimum 4" square) (R407.3) Steel columns (minimum 3" diameter, Sched- ule 40 pipe) (R407.3) UNDER -FLOOR SPACE (R408) Ventilation (R408.1 and R408.2) Unvented crawl space (R408.3) Access (R408.4) Removal of debris (R408.5) Finished grade (R408.6) Flood resistance (R408.7) -5- FLOORS (Chapter 5) WOOD JOISTS AND GIRDERS (R502) TREATED -WOOD FLOORS (ON GROUND) (R504) Species and grade (R502. 1) Base course: 4" thick with maximum 3/y' gravel or'/2' crushed stone (R504.2.1) [Table R502.3.1(1)] Joists—Nonsleeping areas, ILL = 40 psf [Table R502.3.1(2)] Cantilevered joists (Tables R502.3.3(1) and R502.3.3(2)] Girder and header spans (Tables R602.7(1) - R602.7(3)] Joists under bearing partitions (R502.4) Bearing (1.5" minimum on wood or metal; 3" on masonry or concrete) and lapped joists (3") (13502.6, R502.6.1) Lateral restraint and bridging (R502.7, R502.7.1) Drilling and notching (R502.8) Fastening (R502.9) Framing of openings (17502.10) Wood trusses (17502.11) Draftstopping (R502.12) LUMBER FLOOR SHEATHING (R503.1) Allowable span (Table R503.1) End joints (R503.1.1) WOOD STRUCTURAL PANEL SHEATHING (R503.2) Grade (R503.2.1) Thickness (R503.2.1) Allowable spans (Tables R503.2.1.1(1) and R503.2.1.1(2)] Installation [Table 602.3(1)] PARTICLEBOARD UNDERLAYMENT (R503.3) Grade (R503.3.1) Thickness (R503.3.2) Installation [Table R602.3(1)] Moisture barrier: placed over base course (R504.2.2) Materials (R504.3) STEEL FLOOR FRAMING (R505) Cold -formed steel; applicability limits; in -line framing (R505.1) Structural framing (R505.2) Material (R505.2.1) Corrosion protection (R505.2.2) Identification (R505.2.4) Fastening (R505.2.5) Floor construction (R505.3) CONCRETE FLOORS (ON GROUND) (R506) Thickness: 3'/z' minimum; Concrete strength (R506.1) Support: prepared subgrade; maximum earth fill = 8"; maximum sand or gravel fill = 24" (R506.2.1) Base course: 4" graded with 2" maximum aggregate (R506.2.2) Vapor retarder(R506.2.3) Reinforcement support (R506.2.4) EXTERIOR DECKS (R507) Support, attachment (R507.1 - R507.2.4) Plastic composite materials (R5073) Decking/deck joists (R5074, R507.5) Deck beams (R507.6) Deck posts, connections, footings (R5077.1, R507.8) 19 WALL CONSTRUCTION (Chapter 6) WOOD CONSTRUCTION (R602) Material (R603.2.1) X Construction Corrosion protection (13603:2.2) (Figures R602.3(1) and R602.3(2)] Identification (R603.2.4) Stud grade (R602.2) X Design/construction (R602.3) X Stud spacing [R602.3.1, Table R602.3(5)] X Interior load -bearing walls (R602.4) X Interior nonbearing walls: 2" x 3" at 24" o.c. or 2" x 4" flat at 16" o.c. (R602.5) Drilling and notching —studs (R602.6) Drilling and notching —top plate (R602.6.1) Headers (Tables R602.7(1) - R602.7(3) and Figure R602.7.2] X Fireblocking (R602.8, R302.11) Cripple walls (R602.9) Wall bracing, lines, panels (R602.10.1, R602.10.2) Required length of bracing, method (R602.10.3, R602.10.4, Tables R602.10.3(1) and R602.10.3(3)] Minimum length, connections, support, joints, cripple walls (R602.10.5 - R602.10.11) Wall anchorage (SDC C and D) (R602.11) Simplified wall bracing (R602.12) STEEL WALL FRAMING (R603) General (R603.1) Structural framing (R603.2) Fastening (R603.2.5) Wall construction (R603.3 - R603.5) Headers (R603.6) Studs, tracks and structural sheathing (R603.7 - R603.9) SHEATHING (R604 and R605) X Wood structural panels (R604) Particleboard (R605) MASONRY CONSTRUCTION (R606 - R610) X General design (R606) Seismic requirements (R606.12) Glass unit masonry (R607) X Exterior concrete wall construction (R608) X Exterior windows/doors (R609) Glass unit masonry (13610) STRUCTURAL INSULATED PANEL WALL CONSTRUCTION (R610) Applicability (R610.2) Materials (R610.3) Wall panels, construction details (17610.4 - R610.10) -7- WALL COVERING (Chapter 7) INTERIOR WALL COVERING (R702) Wood shakes and shingles (R703.6) Plaster material (R702.2) Exterior plaster (R703.7) /o'�% Stone & masonry veneer (R703.8 & X Gypsum board materials (R702.3.1) X Gypsum board support, application and fas- tening (R702.3.2 - R702.3.7) Ceramic tile (R702.4) Other finishes (R702.5 and R702.6) Vapor retarders (R702.7) EXTERIOR WALL COVERING (R703) X Water -resistive barrier (R703.2) Attachment and minimum thickness ]Table R703.3(1)] Wood siding (R703.5) bearing each end (R703.8.3) Veneer ties: #9 U.S. gage wire or #22 U.S. gage by'/e" corrugated metal; horizontal and vertical spacing; 2:67 square feet maximum area supported (wind > 30 psf and SDC C or D, maximum area = 2 square feet) (R703.8.4.1) Flashing (R703.4 and R703.8.5) Exterior insulation and finish systems (R703.9) X Fiber cement siding (11703.10) Vinyl siding (13703.11) Other sidings (R703.12 - R703.17) ROOF -CEILING CONSTRUCTION (Chapter 8) WOOD ROOF FRAMING (R802) Fire -retardant -treated wood (R802.1.5) Framing details (R802.3) Rafter ties (17802.3.1) Collar ties (4' o.c., in upper third of attic) (R802.3.1) Purlins (2" x 4" at 4' o.c. minimum) (Figure R802.5.1, R802.5.1) X Bearing (R802.6) Cutting and notching (R802.7) X Engineered wood products (R802.7.2) Lateral support and bridging (R802.8) Framing of openings (R802.9) Wood trusses (13802.10) X Roof tie -down (R802.11) CEILING JOISTS [Tables R802.4(1), R802.4(2)] X Without attic storage, LL = 10psf With attic storage LL = 20psf X Spacing X Species and grade X Span X Size RAFTERS [Tables R802.5.1(1) R802.5.1(8)] Ground snow load/LL = 20 psf Controlling design (LL or snow) Ceiling not attached/ceiling attached X Spacing X Species and grade Span X Size Hc/HR; Adjustment factor ROOF SHEATHING (R803.2) X Grade X Thickness FRTW allowable stresses/grading X Allowable spans [Table R503.2.1.1(1)] X Installation (R803.2.3) SD ROOF -CEILING CONSTRUCTION (cont'd.) STEEL ROOF FRAMING (R804) Roof construction (R804.3) General (R804.1) Roof tie -down (R804.3.8) Structural framing (R804.2) Material (R804.2.1) Corrosion protection (R804.2.2) Identification (R804.2.3) Fastening (R804.2.5) ROOF VENTILATION (R806) Ventilation requirements (R806.1 - R806.5) ATTIC ACCESS (R807) Access requirements (807.1) ROOF ASSEMBLIES (Chapter 9) ROOF CLASSIFICATION (R902) Roof covering materials (R902.1) WEATHER PROTECTION (R903) Flashing (R903.2) Coping (R903.3) Roof drainage (R903.4) MATERIALS (R904) Compatibility; specifications; physical charac- teristics; identification (13904.2 - R904.4) REQUIREMENTS FOR ROOF COVERINGS (R905) X Underlayment (R905.1.1, R905.1.2) X Asphalt shingles (R905.2) Clay and concrete tile (R905.3) Metal roof shingles (R905.4) Mineral -surfaced roll roofing (R905.5) Slate shingles (R905.6) Wood shingles (R905.7) Wood shakes (R905.8) Built-up roofs (R905.9) Metal roof panels (R905.10) Modified bitumen roofing (R905.11) Thermoset single -ply roofing (13905.12) Thermoplastic single -ply roofing (13905.13) Sprayed polyurethane foam roofing (R905.14) Liquid -applied roofing (R905.15) Photovoltaic shingles (13905.16) ROOF INSULATION (R906) General (11906.1) ROOFTOP - MOUNTED PHOTOVOLTAIC SYSTEMS (R907) Materials and installation (R907.1 - R907.5) REROOFING (R908) Materials and methods (R908.1) Structural support (R908.2) Replacement/re-covering (13908.3, R908.4) ROOFTOP - MOUNTED PHOTOVOLTAIC PANEL SYSTEMS (R909) Materials and installation (R909.1 - R909.3) CHIMNEYS AND FIREPLACES (Chapter 10) MASONRY FIREPLACES (R1001) Construction (Figure R1001.1 and Table R1001.1) SDC D reinforcing/anchorage (R1001.3 and R1001.4) Firebox walls and dimensions (R 1001.5 and R 1001.6) Steel fireplace units (R1001.5.1) Lintel (noncombustible) (R1001.7) Hearth extension (R1001.9, R1001.10) Fireplace clearance (131001.11) Fireblocking (171001.12) MASONRY CHIMNEYS (R1003) Construction (Table R1001.1, R1003.2, R1003.3, and Figure R1001.1) Corbeling (R1003.5) M PLEASE PROVIDE A SIT PLAN PER PLEASE PROVIDE PRODUCT AND INSTALLATION INSTRUCTION FOR THE FIBER BOARD FOR THE SOFFIT. PLEASE PROVIDE PRODUCT APPOVAL AND INSTALLATION INSTRUCTION FOR THE FIBER BOARD FOR THE SIDING. PLEASE PROVIDE PRODUCT APPOVAL AND INSTALLATION INSTRUCTION FOR THE FIBER BOARD FOR THE MULLION. PLEASE PROVIDE PRODUCT APPOVAL AND INSTALLATION INSTRUCTION FOR THE ROOF COVERING UNDERLAYMENT. PLEASE PROVIDE SITE PLAN PER FBC 2017 6T EDITION 107.2.5. THE CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED GRADES AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE BOUNDARY LINE SURVEY PLEASE CLAIRIFY SECTION —A UPPER FLOOR #18 PLEASE SHOW/PROVIDE DETAIL PER R311.7.10.1 Spiral stairways OF THE FBC-RESIDENTIAL 2017 6TH EDITION PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING THE SQUARE FOOT INFORMATION. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDTITION. THE LOWER FLOOR BATHROOM DOES NOT COMPLY WITH FBC— RESIDENTAIL 2017 6TH EDITION R320.1.1