HomeMy WebLinkAboutDEISGN LOAD COMPLIANCE CERTIFICATE'VeD
SEP 2 0 2919
Planning&Develo mentServicesDe Department AeSt.W,-C,eitting 0artmenr
P i LUUe County
Building &Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982— (772) 462-1553
Certification for Design Load Compliance SCANNED
BY
Project Name: St. Lucie County
Project Address: _ 2-r'1 G'i 1B CrY-1- `f kA p tr -
Permit#: Occupancy Type: SF:::V— Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
' Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2017 Building Code Sixth Edition with 20 N/A Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category:I X II _III_IV Exposure Category:_B X C _D
4. Design Wind Velocity 160 mph X ASD LRFD End Zone Width: 6 ft
5. Mean Roof Height 18 ft Roof Pitch: 6 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 30sgft @ 15'MRH, clearly label on all plan openings):
Zone 1:+2o,-31.3Zone 2:+20,-55.3Zone 3:+20,-81.7Zone 4:+34.y-37.6Zone 5:'34•7,46.5Garage: *2e.5•-32.2
7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: N/A PSF
Dock: N/A PSF Deck: N/A pSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? —Yes X Not Applicable Explain Why Not:
Aspect Ratio <4:1
9.
Is A Continuous Load Path Provided? X
Yes_
Not Applicable Explain Why Not:
10.
Design Soil Bearing Pressure: 2500
PSF
Soil Test Reports Submitted? Yes
Z;Z:;ZN ;:nOFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Donald J. Nuelle
Print Name Cen # & Co. Cert Auth.
Nuelle Engineering 52046
11634 SW Rowena Street, Port St. Lucie, FL 34987
Company Name & Address