Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODERECEIVED SEP 3 0 1019 FORM R405 2017 per St. l �9 a County Dartmenr FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida pepartment of Business and Professional Regulation - Residential Performance Method Project Name: MW-263 SCANNED Builder Name: GHOHOMES Street: 2994 BENT PINE DR Permit Office: SAINT LUCIE COUNTY City. State, Zip: FORT PIERCE. FL , 34951 BY Permit Number. Owner: S(, Lucie County Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) i 1. New construction or existing New (From Plans) 9. Wall Types(2437.1 sgft.) Insulation Area 2. Single family or multiple family Single-ramily a. Concrete Block - Exl Insul, Exterior R=4.1 2144.70 ft- b. Frame - Wood, Adjacent R=11.0 292.44 ft' 3. Number of unil s, if multiple family 1 c. N/A R= ft' 4. Number of Bec rooms 3 d. N/A R= ft' 5. Is this a worst se7 No 10. Ceiling Types (2525.0 sgft.) Insulation Area a. Under Attic (Vented) R=40.0 2525.00ft- 6. Conditioned 1k or area above grade (h') 2525 b. N/A R= ft' Conditioned 0 or area below grade (ft') 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(434, sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 692 a. U-Factor: Dbi, U=0.62 434.69 ft- SHGC: SHGC=0.26 b. U-Factor. N/A ft' 12. Coaling systems kBtu/hr Efficiency SHGC: a. Central Unit 56.0 SEER:16.00 c. U-Fader, N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor, N/A ft' a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems a. Electric Cap: 50 gallons S. Floor Types (525.0 sqf[.) Insulation Area EF: 0.940 a. Slab-On-Grz de Edge Insulation R=0.0 2525.00 fl' b. Conservation features b. WA R= ft' None c. N/A R= ft, 15. Credits Point Glass/Floor Area: 0.172 Total Proposed Modified Loads: 81.28 PASS Total Baseline Loads: 82.23 1 hereby certify that the plans and specifi tions covered by Review of the plans and &,fRE Srq?, this calculation are in compliance with th Florida nergy specifications covered by this BOA '=€}±r" Code. ,✓ 47 calculation indicates compliance y „� ,.n with the Florida Energy Code. mu,:'••:.:,=,=:i•..r.n PREPARED BY: Before construction is completed 09/09n9 DATE: this building will be inspected for O 4. compliance with Section 553.908 I hereby certify i hat this building, as design is in compliance Florida Statutes.Itc with the Florida Energy Code. OD WE'D OWNER/AGENT: BUILDING OFFICIAL: DATE:-� DATE: - Compliance equires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified fact ry-sealed In accordance with R403.3.2,1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402A.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE Cope 919/2019 3:07 IM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-20 7 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Nama: # of Un)ts: Builder Name: Permit Office: Jurisdiction: Family Type: New/Ezieting: Comment MW-263 Bedrooms: 3 User Conditioned Area: 2525 Total Stories: 1 1 Worst Case: No GHO HOMES Rotate Angle: 0 SAINT LUCIE COUNTY Cross Ventilation: No Whole House Fan: No Single-family New (From Plans) - Address Type: Street Address Lot# Bloek(SubilMslon: PlatBook: Street 2994 BENT PINE DR County: St Lucie City, State, Zip: FORT PIERCE, FL. 34951 CUNIATE J Desi Location Design Temp TMY Site 87.5 % 2.5 % Int Design Temp Healing Design Daily Temp Winter Summer Degree Days Moisture Range FL, ort Pierce FL VERO BEACH MUNI 39 90 70 76 299 62 LOW BLOCKS Number Name Area Volume 1 Blockt 2525 23482B SPACES Number Name Area Volume IOt hen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 2525 234825 Yes 4 3 1 Yes Yes Yes FLOORS # FlcorTypa Space Perimeter R-Value Area Tile Wood Carpet 1 Sla n-Grade Edge Insulate Main 216.4 It 2525 fP _. 0 0 1 ROOF J # Type Roof Gable Roof Materials Area Area Color Red Solar SA Emitt Emitt Dock Poch Barr Absor. Tested Tested Insul. (deg) 1 Hip Flat tile/slate, 2824 W 0IN Medium N 0.4 N 0.9 No 0 26.6 ATTIC V# Type Ventilation Vent Ratio (1 In) Area RBS IRCC 1 Fug attic Vented 150 2525 fN N N CEILING Calling Type Space R-Value Ins Type Area Framing Frac Truss Type F7* 1 Under Attic(Verded) Mein 40 Blown 262S ft' 0.1 Wood 9192019 3:07 P EnergyGauge® USA 6.0.02 (Rev.1) - RaRe32017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKL IST RPPnRT i� WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Exterior Concrete Block - Ext Insul S Main 4.1 65 6 9 4 611.3 R' 0 0 0.3 0 _ 1 N -2 NE Exterior Concrete Block - Ext Insul Main 4.1 1 4 11 4 15.1 ft' 0 0 0.3 0 -3 E Exterior Concrete Black - Ext Insul Main 4.1 64 10 9 4 606.1 R' 0 0 0.3 0 -4 S Exledor Concrete Block • Exl Insul Main 4.1 57 2 9 4 533.6 IF 0 0 0.3 0 _ 5 W Exterior Concrete Bbdt - Ext Insul Main 4.1 40 B 9 4 379.6 ft2 0 0 0.3 0 6 - Garage Frame - Wood Mein 11 31 4 9 4 292A ft2 0 0.25 0.3 0 WINDOWS Orientation shown is the entered. Proposed orientation. _ / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separaden IM Shade Screening 1 jt 1 Metal Double (Clear) Yea 0.62 0.26 N 7.0 R' 0 It 0 in 0 R 0 in None None _ 2 In 1 Metal Double (Clear) Yes 0.62 026 N 12.D ft- 0 ft 0 in 0 ft O in None None _ 3 in 1 Metal Double (Gear) Yes 0.62 026 N 31.6IF 0 ft O In O R O In None None _ 4 3 Metal Double (Clear) Yes 0.62 0.26 N 43.31? 0 R 01n 0 R O In None Norte _ 5 3 Metal Double (Gear) Yes 0.62 0.28 N 20.0 IF 0 R 0 in 0 R 0 in None None _ 8 3 Metal Double (Clear) Yes 0.62 026 N 43.8 ft2 0 ft 0 in 0 R 0 In None None _ 7 3 Metal Double (Clear) Yes 0.62 026 N 111.0 fN 0 ft 0 In 0 R 0 in None None _ 8 4 Metal Double (Clear) Yea 0.62 026 N 14.0 ft3 0 ft 0 in 0 1110 In None None _ 9 4 Metal Double (Clear) Yes 0.62 026 N 43.3 R2 0 it 0 In 0 R 0 in None None _ 10 v 5 Metal Double (Clear) Yes 0.62 026 N 36.0 R2 0 ft 0 In 0 R 0 in None None _ 11 5 Metal Double (Clear) Yes 0.62 028 N 24.0 ft2 0 ft 0 in 0 ft 0 in None None 12 5 Metal Double (Clear) Yes 0.62 026 N 48.0 fN 0 ft 0 in 0 ft 0 in None None GARAGE # Floor Area Calling Area Exposed Wag Perimeter Avg. Wall Height Exposed Wag Insulation 1 689 R2 689 ft2 64 ft 9.4 ft 1 INFILTRATION # Scope McBrod SLA CFM 50 ELA EgtA ACH ACH 50 1 Whotehouse Proposed ACH(50) .000414 2739.6 150A 282.85 .15M 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Duna 1 Electric Strip HeaU None COPA 34 kBbdhr 1 sys#1 9WO19 3:07 RM EnergyGauge® USA 6.0.02 (Rev.1) - FleRes2017 FBC 6th Ed10on (2017) Compliant Software, Page 3 of 4 FORM R405-206 INPUT SUMMARY CHECKLIST REPORT COOL)NG SYSTEM # System Type Subtype Elflclency Capacity Air Flow SHR Block Duds 1 Central Until Solt SEER: 16 56 kBtulhr ofm 0.7 1 sy01 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.94 60 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None i None fN DUCTS - / —Supply —Return Air CFM 25 CFM26 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 8 692 f0 Attic 311 ft• Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programabl[e' emtostaf[t:l�Y Ceiling Fans: He�atln8 lxJ Jan (X) Feb CL�JI �1i LlX1J t[X11 A B [[XJ1 SepE]1IL�1J Oct Nov Dec IfX1I Venting ll 11 I[ �I Feb lxJMar Mar lxl�r Apr l 1 M Y l 1 Jun Jul L 1 t 1 S D lxl OctO lxl No [) Dec Thermostat Schedule: HERS 2000 Reference Hours Schedule Type 1 2 3 4 6 6 7 8 9 10 11 12 Cooling (IND) AM 78 78 78 78 78 76 78 78 80 8D 80 80 PM 8o 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 76 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 88 68 58 68 68 08 68 66 66 Heating (WEH) AM 65 66 66 68 66 68 68 68 68 68 68 68 PM 68 68 68 88 68 68 68 68 68 68 68 66 MASS Mass Type Area Thidmess Furniture Fraction Space Defaul 8 .ft. 0 fta Oft 0.3 Main 9/9/2019 3:07 PM E nergyGauge® USA 6.0.02 (Rev. 1) - FleRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPLI DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX` = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Numb r of bedrooms 4. 3 13. Cooling system: Capacity 56.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEERICOP 6. Cord! coned Floor area (sq. ft.) 6. 2525 d) Room unit/PTAC EER e) Other 7. Wind ws, type and area a) U- actor.(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 14. Heating system: Capacity 34.0 c) Arsa 7c. 434.7 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor.(weighled average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor ype, insulation level: a) SI b-on-grade (R-value) 9a. 0.0 b) Wi od, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wail type and insulation: c) Gas fired, LPG EF A. E terior. d) Solar system with tank EF 1. WQQod frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Maasonry (Insulation R-value) 10A2. 4.1 f) Heal recovery unit HeatRec% B. Adjacent: g) Other 1. W od frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Celli type and insulation level a) Ceiling fans a) Under attic 11a. 40.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Kr)ee walls/skylight walls 11c, d) Multizone cooling credit d) Radiant barrier Installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label re quired by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied wJ'th the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed/(or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based installed code compliant features. Builder New Home: 919/2019 3:08:02 PM Date: `mil 1 I (i 110 City/FL Zip: FORT PIERCE, FL 34951 EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Juri dict on: Permit M Job Information Builder: GHO HOMES Community: Lot: NA Address: 2994 BENT PINE DR City: FOIIITPIERCE State: FL Zip: 34951 Air LeHiCa9e test-ReiWts Passing'resultsmust meet eltherthe Performance, Prescriptive, or ERI Method - O PRESCRIPTIVE METHOD -'The building or -dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes par hour at pressure of 0.2 Inch w.g. (50 Pascals)'..In'Cllmate Zones 1 and,2. '. . i Q PER ORMANCE or ERI METHOD -The building or dwellingunit shall be tested and verified as.having an air leakage rate of not exceeding the selects ACH(50) value, as shown on Form R405-2017 (Performance) or R406-2017 (ERI), section labeled as infiltration, subsection ACH50. ACH(50) specified on: Form R405.2017-Eneigy Calc (PeAormaece) or R406.2017 (ERI): . Z000 x 60 + 23483 — Method for calculating buildino volume: CF (50) Building Volume ACH(50) O Retrieved from architectural plans ❑ PASS Code • software calculated fVhen ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g, (50 Pascals) Testing shall be conducted by either individuals as defined In Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(9, (g), or (1) or an approved third party. Awritten report of the results of the test shall be signed by the party conducting the test and provided to ecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace•and stove doors shall be closed, but not sealed, beyond the Intended weatherstripping or other Infiltration control mea ums. 2. Dampers nciuding exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior do ors, if installed at the time of the lest, shall be open. 4. Exterior doors for continuous ventilation systems and heal recovery ventilators shall be closed and sealed. 5. Heating a d cooling systems, if installed at the time of the test, shall be turned off. 6. Supply an return registers, if Installed at the time of the test, shall be fully open. Testing Company Company< Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. I Signature of Tester: Date of Test: Printed N 3me of Tester: License/Certification #: Issuing Authority: 9/912019 3:08:2 2 PM EnergyGauge® USA 6.0.03 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 y� Load Short Form Job. 9 t90R° bate: Sep a, 2018 Entire House By: Make Trade Model AHRI ref Heating Heating Actual a Airflow Static p Space t For. MW-263 2994 BENT PINE DR, FORT PIERCE, FL 34951 Htg Clg Infiltration ledb(OF) 43 91 Method Simplified r db (°F) 70 72 Construction quality Semi -tight in TD (OF) 27 19 Fireplaces 0 range - L i humidity (%) 30 50 ure difference (grAb) 0 65 HEATING EQUIPMENT COOLING EQUIPMENT Make Lennox Trade 16ACX SERIES Cond 16ACX-060-230A Coil CBA25UW-060-230 AHRI ref 202540573 100 EFF Efficiency 12.0 EER,16 SEER it 10.1 kW Sensible cooling 39200 Btuh tut 34434 Btuh Latent cooling 16800 Btuh s rise 17 OF Total cooling 56000 Btuh tw 1867 elm Actual air flow 1867 cim 5r 0.055 cfmBtuh Air flow factor 0.045 cfrNBtuh ure 0 In H2O Static pressure 0 in H2O tostat Load sensible heat ratio 0.73 ROOM NAME Area (ft') Htg load (Btuh) Clg load (Btuh) Htg AVF (ckn) Cig AVF (cfm) MASTER SUITE 333 5764 5942 319 268 HIS WIC 53 892 408 49 18 MASTER BATH 159 1671 1095 92 49 HER WIC ' 74 62 207 3 9 DEN 201 4017 4863 222 219 FOYER 86 1841 2889 102 130 DINING 163 2701 5035 150 227 MECH 38 484 675 27 30 UTILITY 53 68 689 4 31 BATH 2 58 1006 634 56 29 BED 2 ISO 1871 1828 104 82 BED 3 178 1916 1844 106 83 BATH 3 68 1677 839 93 38 REAR VET 50 1199 1580 66 71 NOOK 99 3687 4348 204 196 KITCHEN 222 187 1724 10 78 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. may_ 20103ep�1 RIOMSPage ulte9UrhwsEd201212.1.00R0r102018 Pa l Pe0i ftW, OhteoOHVACWW %3jtp Cake MR Fro,dD"fa W GREAT Raul 428 4379 6598 242 297 UTILITY HALL 95 304 255 17 11 Entire House 2527 33728 41464 1867 1867 Other equip loads 0 0 Equip. @ � 0.95 RSM 39588 Latent cooling 15612 TOTALS 2527 33728 55200 1867 1867 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. C 2018Sep0911A02 y� ght;SOtY Rist0+Se8e0)Unker8e1201212.1.OSRSU02818 Pa9o2 ALA.11 C. menbWAghaos HVACIMVVd63aup Ceb-MJB FmiO Doerfims: W �+ wrightsoft' Project Summary Entire House For: MW-263 2994 BENT PINE DR, FORT PIERCE, FL 34951 Notes: Weather: Vero Beach Municipal AP, FL, US Winter Design Conditions Outsid db 43 OF Inside b 70 OF Desia TO 27 OF Heating Summary Struc re 27993 Btuh Ducts 5735 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping) 0 Btuh Eauioment load 33728 Btuh Make Infiltration Simplified quality Semi -tight 0 Heating Cooling 2527 2527 25587 25587 lour 0.22 0.11 :fm1 94 47 Heating Equipment Summary ure rise Flow 100 EFF 10.1 kW 34434 Btuh 17 OF 1867 cfm 0.055 cfm/Btuh 0 in H2O Job: Date: Sep 6, 2019 By: Summer Design Conditions Outside db 91 OF Inside db 72 OF Design TD 19 OF Daily range L Relative humidity 50 % Moisture difference 65 gr/Ib Sensible Cooling Equipment Load Sizing Structure 31360 Btuh Ducts 10094 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturers data n Rate/swing multiplier 0.95 Equipment sensible load 39588 Btuh Latent Cooling Equipment Load Sizing Structure 12875 Btuh Ducts 2737 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 15612 Btuh Equipment total load 55200 Btuh Req. total capacity at 0.70 SHR 4.7 ton Cooling Equipment Summary Make Lennox Trade 16ACX SERIES Cond - 16ACX-060-230A Coil CBA25UHV-060-230 AHRlref 202540573 Efficiency 12.0 EER, 16 SEER Sensible cooling 39200 Btuh Latent cooling 16800 Btuh Total cooling 56000 Btuh Actual air flow 1867 cfm Air flow factor 0.045 cfm/Stuh Static pressure 0 in H2O Load sensible heat ratio 0.73 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ' + wrighttsoft' RlghtSuite® Universal 201212.1.05 RSUD2818 AE5A C:Use UasonM=rncnMXWdnhWft HVACIMW-263uuP Cal. =MA Front Door faces: W 2019Sep0914:24: 15 Pago 1 HOME5 MW-263 2994 GENT PINE DR FORT PIERCE, FL 34951