Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFlorida Energy Efficiency Code For Building Construction Florida Department of Community Affairs EnergyGauge Summit® Fla/Com-2008, Effective: March 1, 2009 -- C Method A: Whole' Building Performance Method for Commer I I EUildings AN 1) ?Of? PROJECT SUMMARY BY St. Lucie County Short Desc: OFFICE Description: 16891 CAROLE NOON Owner: SAVE THE CHHAPS Addressl: 16891 CAROLE NOON LANE City: FORT PIERCE Addressl: State: FL ". Zip: 0 Type: Office Class: New Finished building Jurisdiction: ST LUCIE COUNTY, ST LUCIE COUNTY, FL (661000) Conditioned Area: 1200 SF. Conditioned & UnConditioned Area: 1200 SF No of Stories: i 1 Area entered from Plans 1200 SF Permit No: 0 Max Tonnage 3 If different, write in: EnergyGauge Summil0 FlalCom-2008, Effective: March t, 2DD9 121812011 Page 1 of? Component Gross Energy Cost (in $) LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? Design Criteria Result 1,-802'.0 1,802.0 PASSED PASSES None Entered PASSES None Entered PASSES None Entered Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report a EaergyGauge Summit® Fla(Com-2008. Effective: March t, 2009 1218l2011 Page 2 of 7 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: PAUL WELCH INC. Building Official: Date: 12 °b Date: I certify that this building is in co liance with the Florida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (*) that the system design is in compliance with the Florida Energy Efficiency Code Architect: Reg No: Electrical Designer: PAUL WELCH INC. Reg No: 29945 Lighting Designer: PAUL WELCH INC. Reg No: 29945 Mechanical Designer: PAUL WELCH INC. Reg No: 29945 Plumbing Designer: PAUL WELCH INC. Reg No: 29945 (*) Signature is required where Florida Law requires design to be performed by registered design professionals. EnergyGauge Summit® FfalCom-2008. Effective: Match 1, 2009 IV 261I Page 3 of 7 Project: OFFICE Title: 16891 CAROLE NOON LANE Type: Office (WEA File: FL_ST_LUCIE_CO_INTLAW) Building End Uses 1) Proposed 2) Baseline Total 115.10 135.00 $1,802 $2,120 ELECTRICITY(MBtulkWhl$) 115.10 135.00 33744 39561 $1,802 $2,120 AREA LIGHTS 11.00 13.80 3234 4042 $173 $217 DOMHOT WATER 58.70 58.70 17213 17213 $919 $923 MISC EQUIPMT 18.00 18.00 5274 5274 $282 $283 PUMPS & MISC 0.10 0.10 18 24 $1 $1 SPACE COOL 15.00 16.00 4386 4694 $234 $252 SPACE HEAT 0.20 2.80 64 825 $3 $44 VENT FANS 12.10 25.60 3955 7499 $190 $401 Passing requires Proposed Building cost to be at most 85% PASSES oSBsseline cost. This Proposed Building is at 85% EneraGauge Summit& FfalCam-2008. Effective: March 1, 2009 12/8/2011 Page 4 of 7 External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) None Project: OFFICE Title: 16891 CAROLE NOON LANE Type: Office " (WEA File: FL ST_I.UCM CO INTL.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq.ft) CP CP ance OFFICE 17 Office - Enclosed 1,200 3 1 PASSES - PASSES Project: OFFICE Title: 16891 CAROLE NOON LANE Type: Office (WEA File: FL_ST_LUCIE_CO_INTL.tm3) System Report Compliance AC-1 CE MOPS MAINTENANCE Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp - Eft Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 13.00 12.23 1.00 PASSES Split System < 65000 Btu/h Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.80 0.90 PASSES System -Supply Constant Volume PASSES EoergyGauge Summit® FialGom-2008. Effective: March 1, 2009 IV&2011 Page 5 of 7 Plant Compliance Description Installed Size Design Min Design Min Category No Eff Eff IPLV IPLV Comp liance ,... ... ,... None Project: OFFICE Title: 16891 CAROLE NOON LANE Type: Office , (WEA File: FL_ST_LUCIE_CO_INTL.tm3) Water Heater Compliance Description Type Category Design Min Design Eff Eff Loss Max Comp Loss liance Water Heater 1 Electric water heater <= 12 [kW] 1.00 0.89 PASSES PASSES Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins [inches] Runont? Temp [Btu-in/hr Thick [in] [F] .SF.F] Reel Ins Compliance Thick [in] None EnergyGauge Summit@ FlalCom-2008. Effective: March t, 2009 IV8r2011 Page 6 of 7 Project: OFFICE Title: 16891 CAROLE NOON LANE Type: Office (WEA File: FL_ST_LUCIE_CO_INTL.tm3) Category Report Operations Manual Windows & Doors Section 13-101 13-102.1, 13-410, 13-413 13=406.":1.1 Joints/Cracks • ' 13406:AB.1.2 Dropped Ceiling Cavity- 13406.AB.3 System 13407 Reheat 13407.13 HVAC Efficiency 13-407, 13-408 HVAC Controls 13-407.AB.2 Ventilation Controls 13409.AB.3 F11ON HVAC Ducts Balancing Piping Insulation Water Heaters Swimming Pools Hot Water Pipe Insulation Water Fixtures Motors Lighting Controls 13-410 13-410.AB 13-410.AB.4 13-4 )1.AB Other Required Compliance Requirement (write N/A in box if not applicable) hzput Report Print -Out from EnergyGauge FlaCom attached Operations manual provided to owner Glazed swinging entrance & revolving doors: max. 1.0 cfm/ft'; all other -products: 0.4 cfm/ft" To be caulked, gasketed, weather-stripped or otherwise sealed Vented: seal & insulated ceiling. Unvented seal & insulate roof & side walls HVAC Load sizing has been performed Electric resistance reheat prohibited Minimum efficiences: Cooling Tables 13-407.AB.3.2.IA-D; Heating Tables 13-407.AB.3.2.1B, 13407.AB.3.2.1D, 13408.AB.3.2.IE, 13408.AB.3.2F Zone controls prevent reheat (exceptions); simultaneous heating and cooling in each zone; combined HAC deadband of at least 5°F (exceptions) Motorized dampers reqd, except gravity dampers OK in: 1) exhaust systems and 2) systems with design outside air intake or exhaust capacity <300 cfrn Duct sizing and Design have been performed Air ducts, fittings, mechanical equipment & plenum chambers shall be mechanically attached, sealed, insulated & installed per Sec. 13410 Air Distribution Systems HVAC distribution system(s) tested & balanced. Report in construction documents In accordance with Table 13-41 LAB.2 13412.AB Performance requirements in accordance with Table 13412.AB.3 Heat trap required 13412.AB.2.6 Cover on heated swimming pools: Time switch (exceptions); Readily accessible on/offswitch 13-41 LAB.3 Table 13-41 LAB.2 for circulating systems, first 8 feet of outlet pipe from storage tank and between inlet pipe and heat trap 13412.AB.2.5 Shower hot water flow restricted to 2.5 gpm at 80 psi. Public lavatory fixture how water flow 0.5 gpm max; if self -closing valve 0.25 gallon recirculating, 0.5 gallon non recirculating 13-414 Motor efficiency criteria have been met 13-415.AB Automatic control required for interior lighting in buildings >5,000 s.f.; Space control, Exterior photo sensor; Tandem wiring with I or 3 linear tluuoresce% iamps>30 W Check -I I_ EaergyGauge Summit@ FlatCom-2008. Effective: March 1, 2009 12(8l2011 Page 7 of 7 EnergyGauge Summit® v3.22 INPUT DATA REPOR Proiect Information Project Name: OFFICE Orientation: North Project Title: 16891 CAROLE NOON LANE Building Type: Office Address: 16891 CAROLE NOON LANE Building Classification: New Finished buildinz State: FL No.of Stories: 1 Zip: 0 GrossArea:°' -1200 SF Owner: SAVE THE CHIMPS Zones No Acronym Description Type Area Multiplier Total Area [S1J ►Sn 1 OFFICE CHRVIPS CONDITIONED 1200.0 1 1200.0 ❑ MAINTENANCE EnergyGauge Summit® v3.22 1 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume [ft] IN [ft] plier [sf] leg In Zone: OFFICE 1 OFFICE CHIMPS Office - Enclosed 25.00 48.00 10.00 1 1200.0 12000.0 [� MAINTENANCE Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: OFFICE In Space: OFFICE 1 Recessed Fluorescent - General Lighting 11 96 1056 Manual On/Off 3 ❑ No vent Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value [ft] fft] plier [sf] [Btu/hr. sf. F] Capacity [lb/cf] [h.&Uffltu] [Btu/sf.F] In Zone: OFFICE 1 --NWALLS Steel siding, 4 in. 25.00 10.00 1 250.0 North 0.0686 2.171 121.04 14.6 ❑ insul, air space, steel siding 2 SWALL Steel siding, 4 in. 25.00 10.00 1 250.0 North 0.0686 2.171 121.04 14.6 ❑ insul, air space, steel siding 3 EWALL, Steel siding, 4 in: 48.00 10.00 " .1. 480.0 North 0.0686 2.171 121.04 14.6 ❑ insul, air space, steel siding 4" W WALL Steel siding, 4 in. . 48.00 10.00 1 480.0 North _ 0.0686 2.171 I21.04 14.6 [] insul, airspace, steel siding ry 12/8/2011 EnergyGauge Summit@ v3.22 Windows No Description Type Shaded U SHGC Vis.Tra W H(Effec) Multi Total Area [Btu/hr sf F] IN [ft] plier [sj] °In Zone: OFFICE In Wall: EWALL 1 EGLASS User Defined No 1.0000 1.15 0.90 12.00 4.00 1 48.0 In'Wall: SWALL 1 S-GLASS User Defined No 1.0000 ,1.15 0.90 6.00 7.00 1 42.0 ❑ 2 SGLASS User Defined No 1.0000 1.15 0.90 4.00 4.00 1 16.0 ❑ Doors No Description Type Shaded? Width H (Effec) Multi. Area Cond. Dens. Heat Cap. R-Value AI [Ft] plier [sf] [Btu/hr. A F] []b/cf] [Btu/sf. F] [h,sf.F/Btu] In Zone: In Wa1L• Roofs No- - Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Deus. R-Value [it] [ft] plier [sf] [deg] [Btu/hr. SE F] [Btu/st F] [Ib/cf] [b.sEFBtu] InZone'.' OFFICE „r,cl -ROOF Construct 1030 25.00 48.00 I 1200.0 0.00 0.0419 6.16 29.37 23.9 ❑ Skylights No Description' Type. U SHGC Vis.Trans R H (Effec) Multiplier Area Total Area [Btu/hr sf F] [ft] [ft] [SfJ [Sq 12/g/2411 EnergyGauge Summit® v3:22 3 In Zone: In Roof: -- Floors No, Description Type Width [ft] H (Effec) Multi [ft] plier Area Cond. Heat Cap. [sf] [Btu/hr. sf. F] [Btu/sE F] Dens. R-Value [lb/cf] [h.sf.F/StuJ In Zone: _OFFICE 1 FLOOR 4 in. heavyweight _ 25.00 concrete 48.00 I 1200.0 3.0030 9.32 140.00 0.33 ❑ Systems AC-1 CHIMPS MAINTENANCE Constant Volume Air Cooled Split System < 65000 Btu/hr No. Of Units 1 Component Category Capacity Efficiency IPLV I Cooling System 2 Heating System 3 ` . Air Handling System -Supply 36000.00 40000.00 1200.00 13.00 1.00 1.00 0.80 -..- - Plant Equipment Category Size Inst.No Eff. IPLV - Water Heaters r, W Heater -Description- - Capacit3Cap.Unit I/P Rt. Efficiency Loss I Electric water heater 30 [Gal] 5 [kW] 1.0000 [EQ!.''' [$ ] 12/8/2411 EnergyGauge Summit® v3.22 4 M 0 Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Control Type Wattage Luminaires Luminaire [sf/ft/No] [W] El .... _- Piping No Type Operating Insulation Nomonal pipe Insulation Is Runout?71 Temperature Conductivity Diameter Thickness [F] [ Btu-in/h.sf.F] [in] [in]. Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/b.sLF] ApLbWndl User Defined 1 1.0000 1.1494 0.9000 ❑ Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHeat Mat No Acronym Description Used [h.sf.FBtu] IN [Btu/h.ft.F] [lb/cf] [Btu/1b.F] . MatA Steelsiding No 60 Mat160 Ceiling air space Yes 1.0000 1❑ 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 57 Matl57 3/4 in. Plaster or gypsum No 0.1488 0.0625 0.4200 100.00 0.2000 21 Mat121 4 in. Insulation Yes 13.3300 ❑ 12/8/2011 EnergyGauge Summit® v3.22 5 9 MatI9 Air space resistance Yes 0.9100 .. ❑ 40 Mat140 4 in. Heavyweight concrete No 0.3330' ' 0.3330 .1:0000 140.00 0.2000 El 7 Mat17 Finish . _-,- ` No 6.4738 :0.0417 0,2400. 78.00 0.2600 ❑ 18 Mat118: 2 in_Wood No 2.3857. 0.1670 : "0:0700 37.00 0.3900 " ' ❑ Constructs Used No Name Simple Massless Conductance Heat Capacity Den?ify -, 12Value �1'71. a Construct Construct [Btu/h.sf.F] [Btu/sf.F] ': t„ :[lb%ef] [hsf:FBtu] s 1008 Steel siding, 4 in. insul, airspace, steel siding No No 0.07 2.17 ' I21:04 -14.6' - ❑ Layer Material Material Thickness Framing No. [ft] Factor__• 1 4 Steel siding 0.0050 . 0.000 ❑ - 2 21 4 in. Insulation 0.3330 0.000 ❑ 3 9 Air space resistance 0.000 ❑. 4 4 Steel siding 0.0050 0.000 ❑ 5 7 Finish 0.0417, _ .. 0.000 ❑ 6 7 Finish 0.0417 •0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density. RValue Construct Construct [Btu/h.sEFI ]Btu/sLF] [Ib/cf] [h.sf.F/Btu]' 1016 4 in. heavyweight concrete No No 3.00. 9.32 140.00 0.3 ❑ Layer Material Material Thickness Framing No. IN Factor 1 40 4 in. Heavyweight concrete 0.3330 0.000 :- ❑; 12/8/2011 EoergyGauge Summit® v3.22 6 No Name' :-_ _,. Simple ` " Massless Conductance Heat Capacity Density RValue Construct Construct,"' /h.sf.F Btu [ ] [Btu/sf.F � ] lb/c [ f] [h.sLFBtu] 1030 Construct 1030 .. No No: 0.04 :. 6.16 29.57 23.9 ❑ Layer •.Material:. Material ...., Thickness Framing L., .. . = No. _ [ft] Factor 1 7 . Finish 0.0417 0000 2 4 Steel siding 0.0050 0.000 ❑ 3 60 Ceiling air space 0.000 ❑ , 4 18 2 in. Wood 0.1670 0.000 ❑ 5 23 6 in. Insulation 0.5000 0.000 ❑ 6 57 3/4 in. Plaster or gypsum 0.0625 0.000 7 7 Finish 0.0417 0.000 ❑ 12/912011 EnergyGauge Summit® v3.22 � y PALL WELCH INC. MECHANICAL ELECTRICAL CIVIL ENGINEERING 1 9E14 S.W. BILTMORE ST. SLATE#1 14 PORT SAINT. LuCIE, FL 349B4 --PHONE (-77-2) 785 = 9H8B FAX (772) 7BS-9933 i f # DATE: 12/812011 SHEETA OF1 .MANUAL."N" HVACIWORKSHEET ROOM: SPACE AREA: 1625 JOB: SAVE THE CHIMPS ZONE•1 '.j ' N. WALL ......................................... 250 S.F. X 3.68 = 920 S. WALL ....................................:.... 250 S.F. X 7.36 = 1840 E. WALL ..............................:.......... 480 S.F. X 4.96 = 2380.8 W. WALL ......................................... 480 S.F. X 6.56 = 3148.8 N. GLASS ....................................... 0 S.F. X 44 = 0 S. GLASS ....................................... 16 S.F. X 49 = 784 E. GLASS ........................................ 48 S.F. X 91 = 4368 W. GLASS ....................................... 0 S.F. X 91 = 0 ROOF ............................................. 1.200 S.F. X 2.2 = 2640 LIGHTS .......................................... 1056 W X 3.41 = 3600.96 PEOPLE ......................................... 8 X 500 = 4000 ............ 160 CFM X 34 = 6440 SUB TOTAL = 29122.56 ' S % DUCT LOSSES = 1456.128 TOTAL = 30578.69 = 1019.29 CFM • USE 3 TON Air- UNIT