Loading...
HomeMy WebLinkAboutENERGY EFFICIENCYFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: JUSTIN & MICHELLE NAVIN Builder Name: SCANNED Street: 6505 PENSACOLA ROAD Permit Office: ST. LUCIE COUNTY BY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: JUSTIN & MICHELLE NAVIN Jurisdiction: St, �UCIe County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New constructionorexisting Addition 9. Wall Types(304.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Adjacent R=13.0 160.00 ft' b. Concrete Block - Ext Insul, Exterior R=4.1 144.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms(Bedrms In Addition) 1(1) d.N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (277.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 277.00 ft' 6. Conditioned floor area above grade (ft') 277 b. N/A R= ft' Conditioned floor area below grade (ft� 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(15.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 35 a. U-Factor. Sgl, U=0.79 15.00 ft' SHGC: SHGC=0.50 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 40.0 SEER:14.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 14. Hot water systems - None required ��y pp'�0►.5pp{F��� 8. Floor Types (277.0 sqft.) ��CFWVWF. eaOR /+ a. Slab -On -Grade Edge Insulatio Fj, =O�r>,pl����{NV a. b. Conservation features Cap: N/A EF: 0.001 b. N/A (CODv mVelt- ,l,A, W + c. NIA ■'rr IE CO4�-Ty {J� 15. Credits CF, Pstat osed Modified Loads: 10.26 Glass/Floor Area: 0.054 PASS Total Baseline Loads: 10.79 I hereby certify that the plans and specifications covered by Review of the plans and T this calculation are in compliance with the Florida Energy specifications covered by this, Code. calculation indicates compliance 0 +t with the Florida Energy Code. PREPA E B Before construction is completed F "` DATE:` this building will be inspected for compliance with Section 563.908 j i.°4 r- I hereby certify that this building, as designed, is incompliance Florida Statutes. f with the Florida Energy Code. (r OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. i' rrlr `/ - Compliance requires an Air Barrier and Insulation Inspection CheckIs9tB�r'n ith 402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 9/25/2019 6:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST RFPnRT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: JUSTIN & MICHELLE NAVIN User JUSTIN & MICHELLE NAVIN 1 ST. LUCIE COUNTY Single-family Addition Bedrooms: 1 Conditioned Area: 277 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 6505 PENSACOLA RO County: St. Lucie City, State, Zip: FT. PIERCE, FL, CLIMATE / V Design Location TMY Site Design Temp 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 277 2216 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 277 2216 No 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 67 ft 0 277 ft' ___ 0 0 1 ROOF / V # Type Materials Roof Gable Roof Area Area Color Red Barr Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 300 ft' 0 ft' Light N 0.6 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 277 it' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 277 ft' 0.11 Wood 9/25/2019 6:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 W 2 S Exterior Concrete Block- Ext Insul Main 4.0999 18 8 144.0 ft' 0 0 0.4 Garage Frame - Wood Main 13 20 8 160.0 ft' 0 0.23 0.4 0 0 WINDOWS Orientation shown is the entered. Proposed orientation. / V # Wall Omt ID Frame Panes Overhang NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 1 Metal Single (Clear) Yes 0.79 0.5 N 15.0 fN 2 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 133 ft' 133 ft' 64ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 184.7 10.14 19.07 .0881 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/Supplemen None COP:1 34 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Supplemental for None SEER: 14 40 kBtu/hr 1200 cfrn 0.8 1 sys#1 SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF ft. DUCTS / V # — Supply — Location R-Value Area — Return -- Air CFM 25 CFM25 HVAC # Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 35 ft' Attic 10 ft' Default Leakage Attic (Default) (Default) 1 1 9/25/2019 6:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPIIT SUMMARY CHFCKI I-RT RFPnRT TEMPERATURES Programabl(e Thermostarxt:']Y Ceiling Fans: Heat ng [X] Jan Feb r , ()C) Mar [[[ Apr r j 4X1 Jun [[ [X� Jul [[[[[M:y[ ]] Aug [[[ ]J] Sep j Do Nov Dee Venting [[ 11 Jan [ ]Feb L l [Xl Mar j J May I) Jun II Jul [ Aug lXJ [ 1 LXl Sep L Occt lxl t Nov Dee Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibsls .ft. 0 ft' 0 ft 0.3 Main 9/2512019 6:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: JUSTIN & MICHELLE NAVIN Builder Name: Street: 6605 PENSACOLA ROAD Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner. JUSTIN &MICHELLE NAVIN Jurisdiction: w Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealingmaterial. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking,or floor framing cavity g insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical(phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire qnronkler cover nl2tes and walls or ceilmoq a. in addition, inspection or log waus snan oe In accoroance wan the provisions of ICCA00. 9/25/2019 6:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply duds R 6.0 2. Single-family or multiple -family 2. Single-family b) Return duds R 6.0 3. No. of units (ifmultiple-family)3. 1 c) AHU location Attic 4. Number of bedrooms 4. 1 5. Is this a worst case? (yes/no) 5. No 6. Conditioned floor area (sq. ft.) 6. 277 7. Windows, tYf HEWED FOR a) U-f Qpf�i I� t 0.790 b) Sola Fi'eaRr a'In�o MO;JAN' r 0.500 c) Are8T. LUCIE COUIV 1 Y - 15.0 8. Skylights BOCC a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood fr���ln�atjgra 2. Mason (I f�G 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 13. Cooling system: Capacity 40.0 a) Split system SEER b) Single package SEER c) Ground/water source SEER/COP d) Room unit/PTAC EER e) Other 14.0 14. Heating system: Capacity 34.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE 0 Other 15. Water heating system a) Electric resistance EF b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec0/o g) Other 10131. 13.0 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans Yes 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. /1 Builder Signature: 0 /� (�j( ✓ Date: v Address of New Home: 6505 PENSACOLA ROAD City/FL Zip: FT. PIERCE. FL 9/25/2019 6:59:07 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Job Project Summary Date: wrightsoft ry , Ent►ie House QUICK CALCS, INC. 317 ST.. LUCIE LANE, FORT PIERCE, FL34946 PhDW: 772.466-6799 Email: OUICKCALCS@AOL.COM Pro*ect Information For. JUSTIN & MICHELLE NAVIN 6505 PENSACOLARD., FT. PIERCE, FL34951 Notes: Design• • Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 i F Dail y range Relative humidity M 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 20827 Btuh Structure 22013 Btuh Duds 5623 Btuh Ducts 7810 Btuh Central vent (0 cfim) 0 Btuh Central vent (0 cf m) 0 Btuh none e) Humidification 0 Btuh Blowner 0 Btuh Piping 0 Btuh Equipmentload 26450 Btuh Use manufacturers data n Rate/sWnggmultipplier 0.95 Infiltration Equipmentsensibleload 28332 Btuh Method Construction quality Simplified Average Latent Cooling Equipment Load Sizing Fireplaces 0 Structure 3117 Btuh Duds 2299 Btuh Central vent (0 ctm) 0 Btuh Area Heatingg Cooling (none) (ft� 1721 1721 Equipment latent load 5416 Btuh Vblume (ftP) 13768 13768 Airchanges/hour Equiv. AVF 0.38 0.20 Equipment Total Load (Sen+Lat) 33748 Btuh (cfm) 87 46 Req. total capacity at 0.70 SHR 3.4 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade EXISTING Model Cond 14AJM42A01 AHRI ref Coil FEM4X4200A1 AHRI ref Efficiency 100 EFF Efficency 13.0 EER,14 SEER Heating Input 6.6 kW Sensible cooling 28000 Btuh Heating output 22663 Btuh Latent cooling 12000 Btuh Temperature rise 50 OF Total cooling 40000 Btuh Actual air flow 412 cfm Actualairflow 1333 cfm Airflowfactor 0.016 cfm/Btuh Airflowfactor 0.045 efm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. _ -P14- wrt htsoft' 2019-Sey2506:55:10 .-....•..ww..�.... RigttStite®Uri..1201919.0.07RSU091o1 Pagel '�� _ SXWrigtt50ft HVACWAVIN, JUSTIN&MICHELLEnp Calc=MI6 FrartDoorfaw& S �+wrightsoft• Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Ptow 772166-6799 Email: 1 3 4 5 Room name R " 111 9 Raomdimensorls Rcornarea Entire House 173.0it 8.0 ft 1721.0 ft' DUSTING HOUSE 155.0ft 8.0 itheaV=l 1.0 x 1410.0 1t 1410.0 ft' TY Con&lx4on number U-value (BtAVW-*F) or HTM (Btuh" Area (fe) or perimeter (ft) load (BLh) Area (ft=J or perimeter (ft) Load (BWh) Heat Cool Gross WS Heat Cool Grass I MPIS Heat Cool -- -'-- - 6 11 �G V�J -6 12C-Osv 1Aclom JAclom-_ 12C-OW 1Aclom 12C-0sv 1Aclom tAclom -11DO 12C-OW tAClom 1Ac1om _ 1W192d i 16B-30ad T2A-tpl�-�-�-- 0.091 1270 -1270 n n _n_ a _e_ 5 s s _s_ w w w � - = 265 35.56 _35.56 255 35.56 2.55 35.55 35.56 _%92 255 35.56 35.56 `1.357 0.90 `27.88 L98 34.77 _34.77 1.96 __ 8706 1.96 34.77 34.77 -10.34 1.96 84.36 87.06 _245 1.60 =0.00 4?A 20 _82 280 _ 30 304 9 60 21 336 6 15 1668 55 _1721. ` 362 0 - --0 250 _ 2 214 9 60 _-21. 315 1 1 _ 1 55 _773 923 711 __2902 637 __1067 545 320 2134 _229 803 213 533 _�.2286 49 _4791 709 695 _28M 489 2612 - 419 313 2086 -217 616 506 1306 _4082 88 ,0 464 20 _-.82 280 30 304 9 60 _21 192 6 _ 0 __ -666 1410 0 _ 1410 962 0 0 923 711 2902 637 1067 __ 545 320 2134 229 ^ 709 695 �2838 489 _ _2612 419 313 2086 _217 364 506 0 �3455 0 _0 0.091 1270 --0.091 1270 1270 250 _ 2 214 9 60 W, I�-GG CG_ C F _0.390 0.091 1270 1270 _6049 0.032 `=0.989 _.21 186 1 0 474 213 0 _. 1935 __ 0 292 _1410 0 d 155 8 c)AED e=rson 0 -553 Emelope lossWn 18143 16976 16382 14150 12 a) Infiltration b) Room ventilation 2683 0 757 01 2404 0 678 0 13 Intemal gains O=P&%S@ 230 Appliarces(odw 6 1380 2900 4 920 2000 Subh#31(lines6hr13) 20827 22013 18786 17747 14 15 Lessexterrlal load Lesstransfer RedistriWtion SubtAW Ductloads 27% 35% 0 0 0 20827 5623 0 0 0 22013 7810 27% 35% 0 0 29 18816 5080 0 0 51 17798 6315 Total room load Airrequired(dm) 26450 412 29823 1333 23696 373 24113 1078 Calculations approved bVACCAtO meet all reauirements of Manual J 8th Ed _ 'H� wri h[so1R- 2019-Sep-2506:55:10 •"° ^"-•�'-- '�Ct` Rigtt-SdteDUriversa1201919.0.07RSW8101 Page .-tslWd9ttmft HVACWAVIN, JUSTIN& MICHELLEnp Calc=MI8 Frord Doorfares S +wrightsoft• Right-J®Worksheet Job: Entire House Date: QUICK CALCS, INC. BY: 317ST.. LUCIE LANE, FORT PIERCE, FL34946 Phore: 772-466-6799 Email: DUICKCALCS@AOL.COM 1 2 3 4 5 Room name E;posedvall Room height Room dimensions Room area ENCLOSED BEDROOM 18.0 it 8.0 it heaVmol 1.0 x 256.0 it 256.0 ft CLS7 0 it SO it hwV=l 5.0 x 11.0 it 55.0 ft TY Constuc9on number U-value (BUTAF-°F) Or HTM (BWhff* Ana (" or perimeter (it) Load (BWh) Area (M or perimeter (10 Load (Btuh) Heat I Cod Gross NrPS Heat Cool Gross NIPS Heat Cool 6 11 tV}J --G U�J�C �C �D 12C-Osv '1Acl= ` 1AcIcm- -O.Os1 1270 1270 n- n _n_ a a -- s s s _s_ w w w ,�, - 2.56 35.56 ._35.56 255 35.56 255 35.56 35.56 _10.92 2.55 35.56 35.56 �J.37 0.90 1.98 -34.77 -34.77. 1.96 87.06 -1.96 34.77 34.77 10.34 1.96 84.36 87.06 _2.45 1.60 _0.00 0 0 0 -0 0 _,_0 0 0 0 0 0 ---0 0 0 0 0 0 0 ^ 0 'o -- ---0 0 0 12C-Ow 1Ac1= 2C-0 1sx 1A-dw 1A-dw 11o0 12C-OW 1AcIom 1Aciom _ -j8&19ad� 16B30ad 22A-ryil- 0.091 1270 ----0.091 1270 1270 0 0 --0 0 0 0 0 '-0 0 0 0 _0 0 0 ---0 0 0 0 252 0 1308 _62! 0 _0 0 0 --` 0 0 0 0 0_ _0 0 0_ -0 0 0 0 0 0 -0 0 0 0 -0 0 0 -0 0 0 _0 0 0 0 _0.390 0.091 1270 1270 `-_,-0.049 0.032 _0.989 _0 144 0 15 _256 0 =256 -0 129 0 1 =256 0 _�18 329 0 533 =351 0 498 _0 0 0 0 0 0 0 �0 0 0 __0 as _0 C_ C •F _0 55 _55 _-.--__0 55 0 . 49 ._ =2769 ==O _____O =o 8 c)AED exansion 556 -3 Enw1opelossigain 1712 2741 49 85 12 a) Infiltration b Rcom ventlatim 279 0 79 0 0 0 0 0 13 hleml gains OowpantsQ 230 Applianombther 2 460 goo 0 0 0 Subtotal(llnes6tl 13) 1991 4180 49 85 14 15 Lessex�r W load Lesstransfer Reclistributon Subbtal Dudloads 27% 35% 0 0 20 2011 543 0 0 35 4215 1495 27% 35% 0 0 -49 0 0 0 0 -85 0 0 Total room load Alrlequired(dm) 2554 40 6710 255 0 0 0 0 Calculations approved byACC_Atp meet all requirements of Manual J 8th Ed �'W' wrygftstsoft- 2019-Sep-2506:55:10 Righ-SUt DUrdverse1201919.0.07 RSU08101 Paget .4CCA tslWrigttwit HVACNAVIN, JUSTIN& MICHELLE.np Calc=MI8 FrortDoorfaces: S �+ wrightsoft° Duct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Plow: 772-466-6799 Email: OUICKCALCS@AOL.COM Project Information For. JUSTIN & MICHELLE NAVIN 6505 PENSACOLARD., FT. PIERCE, FL34951 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.11010.110 in H2O 0.080 in/100@ 412 cfm [i Supply Branch Detail Table Job: Date: By: Cooling 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/100R 1333 ch Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (thin) (cfm) FIR (in) (in) Mail Ln (ft) Ln (ft) Trunk ENCLOSEDBEDROOM c 5710 40 255 0.080 10.0 OXO MFX 12.2 70.0 E)QSTNG HOUSE -A c 24113 373 1078 0.080 19.0 Ox0 VIFx 0 0 Return Branch Detail Table Name Grille Size (in) Htg (dm) Clg (cfiT1) TEL 00 Design FIR Meloc (fpm) Diann (in) H x W (in) Stud/Joist Opening (in) Dud Mail Trunk rb1 Ox0 412 1333 0 0 0 0 Ox 0 �MFx Fit CC)pY Boldhfalic values have been manuaW overridden -'Y- wrightsoft` 2019-Sep-2506:5510 ...+•, .ws..,.a...., Riglt-SUIsOUrivaml 201919.0.07 RSLI08101 Pagel Ct�...1s\W69ftsoRHVACWAVIN,JUSTIN8,MICHELLE.V Calc=MJ8 Fmrl Doorhces S