HomeMy WebLinkAboutTRUSS PAPERWORKi.
20ANNED
BY
St. Lucie County
U.
4451 ST. LUCIE BLVD
FORT PIERCE, FL 34946
PH: 772-409-1010
FX: 772-409-1015
www.A1 Truss.com
TRUSS ENGINEERING I
BUILDER: RENAR
PROJECT. MORNINGSIDE
COUNTY: ST LUCIE
LOT/BLK/MODEL: LOT.79 / MODEL:CAYMAN 1560 / ELEV:B1/ GAR R
JOB#: 77788
MASTER#: WRMSCM1560BlL
OPTIONS: 16X9 PORCH. NO MALLEYS.
r
A-t ROOF
TRUSSES
A FLORIDA CORPORATION
RE: Job WRMSCM156061L
Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3
These truss designs rely on lumber values established by others.
JOB #77788
Site Information:
Customer Info: RENAR DEVELOPMENT CO. Project Name: MORNINGSIDE
Lot/Block: Model: CAYMAN 1560
Address: Subdivision:
City: County: St Lucie
A-1 Roof Trusses
4451 St Lucie Blvd
Fort Pierce, FL 34946
State: FL
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License #:
Address:
City:
General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading
Conditions):
Design Code: FBC2017/TPI2014 Design Program: MiTek 20/20 0.0
Wind Code: ASCE 7-10 Wind Speed: 160
Roof Load: 37.0 psf Floor Load: 0.0 psf
This package includes 43 individual, dated Truss Design Drawings and 16 Additional Drawings.
With myseal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61G15-31.003,section 5 of the Florida Board of Professional Engineers Rules.
No.
Seal #
Truss Name
Date
No.
Seal #
Truss Name
Date
No.
Seal #
Truss Name
Date
1
A0280547
A01
8/22/19
13
A0280559
A13
8/22119
25
A0280571
CJ5
8122/19
2
A0280548
A02
8/22/19
14
A0280560
A14G
8/22119
26
A0280572
CJ5A
8/22/19
3
A0280549
A03
8/22/19
15
A0280561
B01G
8/22119
27
A0280573
UK
8122/19
4
A0280550
A04
8122/19
16
A0280562
B02
8/22119
28
A0280574
CJ5L
8122/19
5
A0280551
A05
8/22/19
17
A0280563
B03
8/22119
29
A0280575
CJ6
8122119
6
A0280552
A06
8/22/19
18
A0280564
B04G
8122119
30
A0280576
GE01
8/22119
7
A0280553
A07
8/22/19
19
IA0280565
B05
8/22/1g
31
A0280577
I HJ7
8/22119
8
A0280554
A08
8/22/19
20
A0280566
B06
8122119
32
A0280578
HHA
8/22119
9
A0280555
A09
8/22/19
21
A0280567
CA
8122119
33
A0280579
HJ7L
8/22119
10
A0280556
A10
8/22/19
22
A0280568
CJ3
8122119
34
A0280580
J7
8122/19
11
A0280557
All
8/22/19
23
A0280569
CJ3B
8122119
35
A0280581
J7L
8/22/19
12
1A0280558
1 Al2
8/22/19
24
A0280570
I CJ3L
8/22/19
36
A0280582
HT
8/22119
The truss drdmng(s) referenced have been prepared by Whole House Engineering,Inc. under mydirectsupervision based on the parameters provided byXl Roef fusses, Ltd.
NOTE:The seal on these drawings indicate acceptance of professional engineering
responsibility soleyforthetruss components shown.
The suitability and use of components forany padicularbulding Is the responsbl'ilyofthe building
designer,perANSVfPl-1 Sec.2
The TrussDesign Drawing(s)(TDD[s]) referenced have been prepared based on the censtructlon
documents (also referred to attunes as 'Structural Engineering Documentsl provided bythe Building
Desgnerindkating the nature and character ofthework
The design uitetiathmin have been transferred to the Truss Design Engineerby JAI RoofTnrsses or
specifn location]. TheseTDDs (also referred to attus as'Slructural Delegated
Engineering Documental are speclaltystruclural component designs and maybe part of the projects
deferred orphaned submittals. As aTmssDesign Englneer(Le, Spsclaky
Engineer),the seal here and on theTDD represents an acceptance of professlonal engineering
resppnsg,igtyforthe design of the single Truss depleted on thaTDD onyi The Binding Designeris
responsi,leforand shag coordinate ayd review theTDDS for -
compatibftwiththe'vwridenengineeringmqu'sert nts. PleaereviewrUDDsandagrelatednotes
K
Page 1 of 2
�y' No: 62809
I.yr:111x.1y
16:43:42-0490'
Truss Design Engineers License renewal date// / I I I I I 1 I
forthe state of Florida is February 28,2021 SERIAL#
5f054982f 500e8feb19a64ef
4451 St. Lucie Blvd.
Fort Pierce, FL 34946
Job
Truss
Truss Type
pry
Ply
h
A0280547
WRMSCM1560B1L
A01
Roof Special
1
1
Job Reference o tional
I
nun. o.uu a mdy m cu
7x10 MT20HS43x6= 2x411
6.00 12 5X6
2x4 II 7 8
7x10 MT20HS=
mausmes, inc. I nu Aug zz 1J:4 Cu l Gina
22 21 18 17 — is
is
3.6 = 4.6 = 2x4 II 2x4 II 4.8 = 3x6 = 1.5x4 II 3x6 =
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in (Joe)
I/deft
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.91
Vert(LL)
0.53 18
>854
360
TCDL 10.0
Lumber DOL
1.25
BC 0.96
Vert(CT)
-1.01 19-20
>452
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 1.00
Horz(CT)
0.58 13
n/a
n/a
BCDL 7.0
Code FBC2017/rP12014
Matrix -MS
LUMBER -
TOP CHORD 2x4 SP No.2'ExcopY
T3: 2x4 SP M 30
BOT CHORD 2x4 SP N0.2'Except'
B2,84: 2x4 SP No.3
WEBS 2x4 SP No.3'Except'
W3: 2x4 SP No.2, W6: 2x4 SP M 30
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 2.4-14 oc
pudins.
BOTCHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS
1 Row at midpt 10-17
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
149010-7-10 '(min. 0-1-12)
13 =
1490/0-7-10 (min. 0-1-12)
Max Horz
2 =
-138(LC 10)
Max Uplift
2 =
-377(LC 12)
13 =
-030(LC 13)
Max Gmv
2 =
1490(LC 1)
13 =
1490(LC 1)
FORCES. (lb)
Max. Comp./Max, Ten. - All forces 250 (lb) or less except
when shown.
TOPCHORD
2-3=-2664/1666, 3-4=416312474, '
4-5=4061/2489,5-6=4033/2514,
7-8=-254/176, 6-8=-5646/3203;
8-9=-5890/3353, 9-10=-5842/3342,
10-11 =1 997/1402, 11.12=2105/1392,
12-13=2688/1678, 6-7=-270/7911 —
BOTCHORD
2-22=1303/2308, 19-20=1752/3602,
9-19=-2961266, 16-17=1338/2336,
15-16=1338/2336, 13-15=1338/2336
WEBS
3-22=-1339/845,20-22=-1523/2709,
WEBS
3-22=1339/845, 20-22=4523/2709,
6-1 9=1 278/2608,17-19=113412387,
10-17=-1262/578, 12-17=619/549,
6-20=335/499, 3-20=559/1368,
10-19=-2209/4464
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=l60mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psF, h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
pending.
4) All plates are MT20 plates unless otherwise
indicated.
5) This truss has been designed for a 10.0 psf bottom
chord live load nonconcument with any other live
loads.
6)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-M wide will fit between the
bottom chord and any other members.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 377 lb uplift at
joint 2 and 430 lb uplift at joint 13.
8) Graphical pudin representation does not depict the
size or the orientation of the pudin along the top and/or
bottom chord.
LOAD CASE(S)
Standard
Dead Load Deft. =121n
PLATES GRIP
MT20 244/190
MT20HS . 1871143
Weight:2241b FT=10%
✓>y+��a1+v a.au-na xooFrPGasrs l'saLFRTfEarJe.d<cemmoxs WsrpYEP leurvnhcicxm+�bcuvxrrmm.v, tev� .dwai.Kmmvm T,una.m+�+w Rwl.=a e.s
+qva%E,4�^A,�mweRYdst b�m.!M UnMA�s.bF'�wtMl[10.e^�`NN, �F WmeYb Gl��WaLO uwObM"nl�bA aG4 M.YM ai9�y
£nQ�w'Ipp.ne6p4yEry-kol.iti•Aka^etYTO�Mm%M!,bsn JeM BeWap PE63POd
' agba.NSsflm...Ynd�.9aie^GMbKdmB!dO�vN�T,m Jp[4} TM��.�.,,Js$1iLTha0u4'i� uR =A MdnO F,m. vS�Ni MurNgnLmbglEW<ObU. wpiutFMm9a'.. NMb Houu EFhMnY C.1911I!
o.,e.,e.ov.rw�e.s.mo-nev.+N.b�rer am.wraawcrss.®Ceueaaaw 'mi.}l,.yvo-mm,Mmo o-nade.dw'Rm:".mawa .ua.s,me•sn..en'.ow.waw
mG�Nl�d4�Nfabvlm NmneuldNa.'NG r9 E'^P?y*adi.aa^.^mBe 4'iin3Ybr,AiM�41 IN+msamXa=.N.w�MW>1NW3&'.R`a..eMe+Wla W,b�a0m9vry �`�Y�.. .t5161 Wtle &M
Fry Y "rPHAFMn U+,efFovTnee;-M FL Pb,u.M13,9y
4WAc(MTrvMT1uNm.Y�YEi9n�NTMYwNalmmbbabAM0. 66wC K.CN6etT9rvM.W�i,iWbllO�.en,MlT�.6paTYENb iautmTM6mM+9 Me4V�aTrvA 6YeW,EnP�.[W VY+gM �M: L52i2M9
[sE+I�Wm.AM0.4MhTY4l.'CtgPffiJLi91B4r gm,T.ws1.-RSP+s+b+tl OYdwnw'{InaY �vY.YAWb1M.iWOl'ni\,iAmb,koAFl Foii�
1
Truss
Truss TypeOtyPIyA0280548
F'wcMSCM1560131L
A02
Hip
1
1
Job Reference (notional)
A-1 Roof Trusses, Fort Pierce, FL 34946, design@aluuss.com
Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek
6.00 12 5x6 = 2x4 11 6x8 =
Inc. Thu Aug 2213:41:04 2019 Page 1
IU1t77uhF22kbPwdxdxWoC1 W16y117D
20 19 16 15 — 13
3xfi =
46 = 2x4 11 2x4 11 5x8 = 3xfi = 3xfi =
III i 11-11-2 1 15$-0 I 19-1-6 1 22-4-0 I 29-3-14 38-0-0 I
74-0 47-2 3-8-14 1. 3-2-10 6-11-14 8-8-2
Dead Load Dar. = 7/161n
Plate Offsets (X,Y)—
16:0-3-0,0-2-01,18:0-&10,0-2-81,rl5:0-2-8,0-2-01,117:0-2-0,0-3-81,
118:0-3-8,0-2-121
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
Well
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC
0.99
Vert(LL)
-0.41 17-18
>999
360
MT20 2441190
TCDL 10.0
Lumber DOL 1.25
BC
0.89
Vert(CT)
-0.81 17-18
>562
240
BCLL 0.0 '
Rep Stress Incr YES
WB
0.80
Horz(CT)
0.48 11
n/a
n/a
BCDL 7.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 221111 FT=10% '
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2 *Except*
B2,B4: 2x4 SP No.3
WEBS 2x4 SP No.3'ExwpY
W3,W7,W6:2x4 SP No.2
BRACING-
TOPCHORD
Structural wood sheathing directly applied.
BOT CHORD
Rigid ceiling directly applied or4-7-15 oc bracing.
WEBS
1 Row at midpt 8-15, 10-15
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
149010-7-10 (min. 0-1-12)
11 =
149010-7-10 (min. 0-1-12)
Max Horz
2 =
-139(LC 10)
Max Uplift
2 =
-378(LC 12)
11 =
-378(LC 13)
Max Gmv
2 =
1490(LC 1)
11 =
1490(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOPCHORD
2-3=-2664/1664, 3-4=4164/2474,
4-5=-4062/2489, 5-6=4171/2629,
6-7=-4081/2370, 7-8=-4045/2360,
8-9=-1836/1336,9-10=-194811312,
10-11=-2612/1629
BOTCHORD
2-20>1301/2307, 5-18=-224/270,
17-18=1455/3218, 14-15=-1266/2250,
13-14=1266/2250, 11-13=-1266/2250
WEBS
3-20=-13361841, 18-20=-151612704,
6-18=-746/926, 6-17=-561/1302,
15-17=1309/2960, 8-15=-2068/846,
WEBS
3-20=-1336/841, 18-20=-1516/2704,
6-18=746/926, 6-17=561/1302,
15-17=1309/2960, 8-15=2068/846,
10-15=718/630, 10-13=0/300,
3-18=-564/1371, 8-17=-1604/3565
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf, BCDL=4.2psf; 4=1511;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces 8 MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load ncnconcurrent with any other live
loads.
5)' This truss has been designed for a live load of
20.0psf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 378lb uplift at
joint 2 and 378 lb uplift at joint 11.
LOAD CASE(S)
Standard
nu�oM rlxv#.*vLsss �s[ur-sA ce,wairnvs.eweaolrmxsasmnEa�ev�E�uxrwwae-�vP+�n. mry�wppvnvc�prs.e.a a,T�moaw�+vilm).=aw
Q �u'�GNb9°,vMY n,etl Ca*atl+vw unwmibrss'Mnmp. No lx0i+m�AtlmoVMaaY +ealm9n Too 44 fa �a�Egrwnag04SwearyEnT+vY w.clwanY T00 repme�. ,n. JenaBMnl=PEexae
��yg�vaadNPbn� ppPv,n¢,wyvcbpbBdMAo.MM irvv Ypb]mb1M My..wW]{4Ylly mvq�sw'pbr>dG¢W�n,v4lYY�uw4WLwber �bryvN�.m�n,LdQ.JM. WM'e WUSe E,gFeerinp G91815
RPW
Dw,MOvd�Miv�C� BWLg Poaq�vr't� tlM 0NI9G W0tlCaVvN mElP1.r T1`4VVN lOn AO'MN WOV Twi'^"169T*cM.a }isul ed,+vu'9GY ,uWVMM1M' u YSIfiow
R.sMY��nomFe'¢Nr<R'1m�M,W'aMvq PiM Na PYNaf Gna+gttMBuIE*I�TAS^P 4lM' $b�fo6WP^o�aM]iZPIaW6oLA ,e4vrcvJA¢P�e,®9 ba�c "iP.Fi.4Rm.MveF^P�i+!mtl D.:0 19
con 0.creT 'C§.?%�ffiv EN agTrvr Pnaammc'w�ue eTmKSYroH4 M(COWenbam v�.iw.Op hNPW MOM;M Ths6.'vnagErglww§HOTN BWvs Potivv,e T,oa eyal§„Enpu4r Nm,Y trmsn¢.'iA ON: fl2YR018
�aWlalM,v wcCaM1.W niPL1.'IXOY� Oi01641 PSITueya_papyzc�tlpyygy,�tinn.yy„aLpµaMdpnppvclb,pnpc m<(M MAT,u¢¢
Job
Truss
Truss Type
Oty
Ply
W
A0280549
WRMSCM156081L
A03
Hip
1
1
-
Job Reference (optional)
A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Pnnt: 8.210 s May 18 2018 MiTek Industries, Inc. Thu Aug 22 13:41:05 2019 Page 1
ID:ld_0OXyyT61Bl_TXc1jwHHzefvK- iIEKRRquOZLelaCRPmH5y7dGlyuc9YfOsm3aYyll7C
204-0
1J-Q ]-0-0 11-11-2 17-&0 1418 2&10-12 3940 a9J-0
110 Z14 d-7-2 I S 1d I1-Sa Ba-12 9-ti 1
1-2-10
6.00 F12 5x10 % 6.6 =
20 19 75 14 — 12
3z6 = 416 = 2x4 II 3x4 11 3.6 =
3.6 =
6x6 =
Dead Load Defl. = 51161n
20J-0
]d-0 11-11-2
17-
19-1.1
2&10-12
3800
]sU I d-7-2
6 1d
i-5G
e-&12
41A
1.2-10
Plate Offsets (X,Y)—
[4:0-3-0Edoel 17:0-3-0,0-1-e1[12:0-3-0.0-2-01.[16:0-2-8,0-3-01.[18:0-5-4,Edgel
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL.
in (Joe)
I/deg
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TIC
0.80
Vert(LL)
-0.33 15
>999
360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC
0.91
Vert(CT)
-0.6017-18
>765
240
BCLL 0.0 '
Rep Stress Incr YES
WB
0.97
Horz(CT)
0.40 10
We
n/a
BCDL 7.0
Code FBC2017ITP12014
Matrix -MS
Weight:221Ib FT=10%
LUMBER -
TOP CHORD 2x4 SP 2400F 2.0E *Except*
T3: 2x4 SP No.2
BOT CHORD 2x4 SP N0.2 *Except*
B2: 2x4 SP No.3
WEBS 2x4 SP No.3'Except*
W3: 2x4 SP No.2
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 2-2-0 or,
pudins.
BOT CHORD
Rigid ceiling directly applied or 4-2-6 oc bracing. Except.
10-0-0 oc bracing: 14-16
WEBS
1 Row at midpt 12-16
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
149710-7-10 (min. 0-1-12)
10 =
1498/0-7-10 (min. 0-1-12)
Max Horz
2 =
-156(LC 10)
Max Uplift
2 =
-387(LC 12)
10 =
-387(LC 13)
Max Grav
2 =
1497(LC 1)
10 =
1498(LC 1)
FORCES. (to)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
TOP CHORD
2-3=-2674/1670, 3-4=-423112526,
4-5=-4123/2541, 5-6= 3329/1912,
6-7=-3331 /1979, 7-8=3683/2093,
_8=9_381512064, 9-10=26.17/1630_ _
BOT CHORD --
2-20=-1306/2317. 5-18=-206/367,
17-18=-199813877, 16-17=-1221/2990,
10-1 2=-1 26612256, 7-16=642/1337
WEBS
3-20=-13541854, 18-20=-1524/2714,
WEBS
3-20=-1354/854,18-20=-152412714,
5-17=891f794, 6-17=363/566,
6-16=341f795, 9-16=-103/1041,
9-12=1088/759, 12-16=-1453/2556,
3-18= 613/1427
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces 8 MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcument with any other live
loads.
5)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-M wide will fit between the
bottom chord and any other members, with BCDL =
7.Opsf.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 387 lb uplift at
joint 2 and 387 lb uplift at joint 10.
LOAD CASE(S)
Standard
Rvm.tlwyMre.c.w•x.r>wpc.TaWscsCse,liq'l. cE96xa. tE�ws.acbmmaxa wsrouu6a ��,,rr,run<carohEwa�eil'bmvwti^rwe^�w«d wa..emaaer Tm omp.mnMAdd)+�d+
Q �vq'ecru.vA+..mudama.uif*+�..aua�.+i.Ma ynwaYns.m}aYwow,.an cwnc+gauelmewTooaay.se,owT.uoo.:9„F�ml...ron.:s,.oa'r, e"v+).e.r+menPtoo,1rr+»..n: JaN
kmieaemlq R:6tb9
mns•awww+ vg.ea+w J/,srt'GnwJm.onr�.. Giw e.Tooway T+t�lnCeg vma..am.btlw we.w^�NLt•eu�aml.�ezm�i errreaa..ruemsvaew.. xouu Eros=Moulls,s
wo...�.cmuoa ro%aaID:9,mssq anb.�r.hFamt3a NauG.M+I6S4NtiuIbV c-6.aTF1'�lbblM��.ap�"a.n v.Tww.nvma,mawT' i++6m�T�*.^9���w..euo.mmd L�rsawme. a.�mm�N;. us, sr+w ene.
aDeeuieNRgMoa CTtr+�br Nmheal wIXR, 2100 mNQwMNusaMP^a�?BAIMB�iGm/G idWFtlRYI,.bnms l�aCa�45Meh'1PIsa 58CJ.eiinM1rtvtaalofM�^19a0e,re; laH.aernh Mmw�a"la4aa RRmu.ft]19K
Mws M2w Tmf Cnxr�.EpcaJEryiR�e.OT,W 4wls4a�cwtis,�xa§a OkwCMaCwYm+T�.�e��EUV M/i�A+M�I]h 6puR(Erti�mVl�TM9N4,9 Mvvm-vTM6YMn 5i9*!tibvp!WP69: <A ase: 6V6R%9
Ca�PYztlbmp RwihmenP,Ll.'Cpyryp O'O18AtPML�,-AgWrc9TaPUG,mqe;timyAmlA➢IXipb]NOwfNO.wM1lpnpmvl„m tlPr1 FaRTvu¢' '
russ
Truss Type
QtyPlyA0
PMSCM156OBiL
�A(14
ROOF SPECIAL
3
1
Job Reference (optional)
A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com
Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 Mhrek
Inc. Thu Auq 2213:41:06 2019
6.00 12
5.6 =
Dead Load De0. = 9/16 in
5
5z6 G
5x6
4
6
1.5x4
W
3
1.5x4 a
3
12
6z8=
1
ry
a
14 13
11
70
1
d
y2� 1 2
MT20HS%3.00
3x8 MT203A
19 is
O
3x4 12
1.Sr14594 II
d
1.5x4 II
1.5x4 II
Sze =
4z8 %
1.6x4 II
5x8 //
3N915
9-10.4
19-0-0
27-16 28�142 31�6 3aL-n
410A
I 9-1-12
8-1-6 -0 2-8-4
7 &
Plate Offsets (X Y)—
12:0-1-14 Edcel 14:0-3-0 0-3-01 16:0-3-0,0-3-01 f8:0-4-7,Edgel,
f8:0-4-0,0-4-121, f8:0-2-1,Edgel
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL,
in (loc) Weill
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.71
Vert(LL)
0.5512-14 >826
360
MT20
2441190
TCDL 10.0
Lumber DOL
1.25
BC 0.84
Vert(CT)
-1.0412-14 >437
240
MT20HS
1871143
BCLL 0.0
Rep Stress Incr
YES
WB 0.91
Horz(CT)
0.65 8 n/a
n/a
BCDL 7.0
Code FBC2017/TP12014
Matdx-MSH
Weight: 200 Ib
FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2 *Except*
T1: 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3 *Except*
W6,W5: 2x4 SP No.2
WEDGE
Left: 2x4 SP No.3,
Right: 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 2-2-0 oc
pur ins.
BOT CHORD
Rigid ceiling directly applied or 4-6-12 oc bracing.
Except:
4-7-0 oc bracing: 8-10
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quide.
REACTIONS. (Ib/size)
2 =
1490/0-7-10 (min. 0-1-11)
8 =
1490/0-7-10 (min.0-1-11)
Max Hom
2 =
166(LC 11)
Max Uplift
2 =
-399(LC 12)
8 =
-399(LC 13)
Max Grav,
2 =
1490(LC 1)
8 =
1490(LC 1)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOPCHORD
2-3=-4697/2907, 3-4=-4307/2635,
4-5=-3134/1852, 5-6=3134/1852,
6-7=432112660, 7-8=-4676/2926
BOTCHORD
2-14=2490/4232, 13-14=1906/3619,
12-13=-1902/3644, 11-12=1905/3647,
10-11=1916/3622, 6-10=-2507/4245
WEBS
5-12=-1338/2394, 6-12=-864/801,
WEBS
5-12=1338/2394, 6-12=-864/801,
6-10=-285/576, 7-10=-352/445,
4-12=861/796, 4-14=-280/568,
3-14=356/464
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult-160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; End., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise
Indicated.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-M wide will fit between the
bottom chord and any other members.
6) Bearing at joint(s) 2, 8 considers parallel to grain
value using ANSI/TPI 1 angle to grain fonnula.
Building designer should verify capacity of bearing
surface.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 399 lb uplift at
joint 2 and 399 lb uplift at joint 8.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
Oty
Ply
.k
A0280551
WRMSCM1560BlL
A05
SCISSORS
4
i
-
Job Reference o tional
A-1 ROOT Trusses, Fort Pierce, FL 34946, designCdalbuss.com
4z8
Run: 8.210 s May
6.00 12 5x6 =
5
5x8 G
5x8 O
4 6
12
6x8 =
14 +3 11 10
3x8 MT20HS% 3x8 MT20HS--
3x4 � 3.00 12 3x4
Inc. 1 DU AUe 2 ld:41:Ub
Dead Load per. = 91161n
1.5x4
7
1
N
+ "a
89 rg
4x8
9-8-14 19-0-0 2832 Mao
� o.a14 F 2.'t2 I 4.'L2 I 4A-14 �
Plate Offsets (X Y) -
12:0-1-14 Edne7 f4:0-3-12 0-3-01
16:0-3-12
0-3-01
f8:0-1-14
Edgel
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/deg
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC
0.71
Vert(LL)
0.58 12-14
>789
360
MT20
2441190
TCDL 10.0
Lumber DOL 1.25
BC
0.83
Vert(CT)
-1.08 12-14
>420
240
MT20HS
187/143
BCLL 0.0 '
Rep Stress Incr YES
WB
0.92
Horz(CT)
0.69 8
nla
n/a
BCDL 7.0
Code FBC2017[rP12014
Matrix -MS
Weight: 1801b
FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2 *Except'
T1: 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3,
Right: 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 2-2-0 oc
purins.
BOT CHORD
Rigid ceiling directly applied or 4-5-14 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quids.
REACTIONS. (lb/size)
2 =
1490/0-7-10 (min. 0-1-11)
8 =
1490/0-7-10 (min. 0-1-11)
Max Hom
2 =
-166(LC 10)
Max Uplift
2 =
-399(LC 12)
8 =
-399(LC 13)
Max Grav
2 =
1490(LC 1)
8 =
1490(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOPCHORD
2-3=-4730/2950, 34=-4291/2612,
4-5=-3137/1854, 5-6=3137/1854,
6-7=-4291/2626, 7-8=4730/2972
BOTCHORD
2-14=2537/4265, 13-14=-1916/3626,
1213=191213651, 11-12=-191713651,
10-11=1921/3626, 8-10=2560/4265
WEBS
5-12=1350/2406, 6-12=-867/806,
6-10=239/565, 7-10=386/506,
4-12=-867/807,4-14=-241/565,
3-14=-386/508
WEBS
5-12=1350/2406, 6-12=-867/806,
6-10=239/565, 7-10=-386/506,
4-12=867/807,4-14=-241/565,
3-14=386/508
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp.B; Encl., GCpi=0.18; MWFRS (envelope)
and GC Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise
indicated.
4) This truss has been designed for a 10.0 psf bottom
chord live load n0nconcurrent with any other live
loads.
5)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Bearing at joint(s) 2, 8 considers parallel to grain
value using. ANSI?PI 1 angle to grain formula.
Building designer should verify rapacity of bearing
surface.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 399 Ito uplift at
joint 2 and 399 lb uplift at joint 8.
LOAD CASE(S)
Standard
wmea,em.pNr ��-, aopr�NmsTa rsE,JYs1j,'�ExEn4 teumfi.mtammwpeusroxex zc6emrn6acmr+n-.n n.v.,Naa+a^ «e�.,a mnv®o..�uewd0rtr«u n. Q TyaryEM+aw Miens m+m tatm WR unrsae+,eYcpeu mme mo. m}wp4ow+,aarvmw- puaEmeT[OmaYe6C..NeYrvalMsyw P�:eveN-y E+q,v1.p++eYmer.rm6,geaeom Jan106mly PEORpP
,eY�p¢NeWegev�p.upotllybes6sppdp�ng�e S�ue.PmmAeTooad xiv Jqd ThaGupnr�.my bmybvl�yemCNin wvLaL)maurab ,perrgup'gePenepfn.,bGq Naa. K1oie Hmw Erym(wlnpG61616
a..m.v.w.nenaaydmJ+.fiwama.4+stimv..a,eaam.aco.ieSe,awsem*mm mJ!«i'tivo-u,amw Tona..enrrw.o.au.Tr�nwm36�-[ti aaew.�mn.ae,awcauruevwn+rm.auv us,swoeaw.
dvie Wiu Cegb^aTa CumYWW�HeMsxela9 eTaPimpe.in.c!¢S xJp.eblwlalK B,tbnpPq°i`R^YEtiv,Y ln*amM' I6666puaiaMp HiiRmeSBCA ei M,mvsaJa�uu,m 9'�6n,n: IPNCeR+I p<h>pnuY+M.er.<. RFmu.R9.9H
emwae,ei,�omc=..sp.mar v9Aw+ad THa,4wm9eef.vMdlee�. uG�¢t+UeAEMMeLwWrtt�.eSKubi,A^pLt/Wrn FwIn61M1e 6P�mN E^1�VN?TMBuW+9�f�T!vTrvaSr�+EeNe.tOtepmm6'N; M Oae: 042VAfB
'emw'=.am+:.=.exn.ervTwr:e.nrW ea.enevmr-Am.�m.mpnm=...e,.w.n.n",.sv�n.a.e�mv..,e,.�ve�..,+•.ae.,wxT„�� ,
Job
Truss
Truss Type
Oty
Ply
A0280552
WRMSCM1560BIL
A06
ROOF SPECIAL
1
1
Job Reference (ptiona0
n-, rtaor , rvs>es, run rrorce, r� .w w,yuL.n
3x6 =
io4uwmuex
ID:Id_0OX yi1Bi TXoljwHHzefvK-w
7-1-4 1Z -0 25-0-1 30-5-12
6-0-5-5-ti
6.00 rl2 5x6 =
6
3x64
5x6 G
5
4 W4
3x4 i
3
13
W2 6z8=
3
N6z8 =
3.00 12
16 15
6.6 = 2.4 11
inc. i nu qua 22
Dead Load Dan. = 71161n
5x6 J
7
1.5x4
e
6 �
12 71 5 d
3x6MT20HS-- 2 1110,7
300
Us c
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defi
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC
0.71
Vert(LL)
0.49 11-13
>924
360
TCDL
10.0
Lumber DOL
1.25
BC
0.98
Vert(CT)
-0.96 11-13
>474
240
BCLL
0.0 '
Rep Stress Ina
YES
WB
0.89
Horz(CT)
0.57 9
We
n/a
BCDL
7.0
Code FBC2017/TPI2014
Matrix-MSH
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30 *Except-
B1,B3: 2x4 SP No.2, B2: 2x4 SP No.3
WEBS 2x4 SP No.3 *Except*
W3: 2x4 SP No.2
WEDGE
Right: 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 24-4 oc
pudins.
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS
1 Row at midpt 4-13
MTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
149010-7-10 (min. 0-1-12)
9 =
1490/0-7-10 (min.0-1-11)
Max Horz
2 =
166(LC 11)
Max Uplift
2 =
-400(LC 12)
9 =
-400(LC 13)
Max Grav
2 =
1490(LC 1)
9 =
1490(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-2649/1686, 3-4=4340/2667,
4-5=-3153/1816, 5-6=-3052/1841,
6-7=-3136/1856, 7-8=4315/2672,
8-9=-4678/2898
BOTCHORD
2-16>1316/2291. 4-14=-233/447,
13-14=2135/3999, 12-13=1897/3634,
11-12-190113609, 9-11=-2479/4215
WEBS
3-16=14511920, 4-13=-1175/1004,
WEBS
3-16=1451/920, 4-13=-1175/1004,
6-13=-1286/2346, 7-13=-853/776,
7-11=315/579, 8-11=337/439,
14-16=-156612749, 3-14=720/1562
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult--160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B;Encl., GCpi=0.18; MWFRS (envelope)
and C-C Extedor(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise
indicated.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Bearing at joint(s) 9 considers parallel to grain value
using ANSI/TPI 1 angle to grain formula. Building
designer should verify capacity of bearing surface.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 400 lb uplift at
joint 2 and 4001b uplift at joint 9.
LOAD CASE(S)
Standard
PLATES GRIP
MT20 2441190
MT20HS 1871143
Weight:1931b FT=10%
Job
Truss
Truss Type
Oty
Ply
y
A0280553
WRMSCM1560BIL
A07
ROOF SPECIAL
1
1
Job Reference optional)
A-1 Roof Trusses, Fort Pierce, FL 34946, design@albuss.cem
Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MTek Industries, Inc. Thu Aug 22 13:41:08 2019 Pagel
ID:Id_OOXyy 61Bl_TXoljwHHzefvK-OHRMyTUiBLxwVUlm7XJ-Jal9_VzTpYV5ig7kAtylI7f
19-9-7
7-4-0 7-6-4 11-10-12 18-2-9 79- 25-0-7 1 -72 38-0-0 9d-0
y$4 41A ~ 6-3-13 ,t�q. s2-10 bs11 ~ 7-64 -0
6.00 12 5 H 7 Dead Lead Defl. = 7116 in
3x6 G
5x6 i
5
4
3x4 i
3
W2
N
y[ 3
d i 2 Ng
16 15
36= 616= 2x4 II
W4
13
5.6 =
5x6 1
7
12 11
3.00 12 3.8 MT20HSx
a=4;
1.5x4 G
8
7761-00-12 9i 79
8 I ,19-7-9
398-7-0.0-07
48
N
A
O
910 `7I
a `9
Plate
Offsets (X.Y)- (7:0-3-0,0301. T9:0-t-14.EdgeI, rl3:0-2-8,0-3-81, 114:0-5-8,04-81
LOADING (psf) SPACING- 2-M ` CSI. DEFL, in (loc) I/deO Ud PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 Vert(LL) 0.49 11-13 >924 360 MT20 244/190
TCDL 10.0 Lumber DOL 1.25 BC 0.98 Vert(CT) -0.96 11-13 >474 240 MT20HS 1871143
BCLL 0.0 ' Rep Stress Incr YES WB 0.89 Hom(CT) 0.57 9 n/a n/a
BCDL 7.0 Code FBC20171TP12014 Matrix-MSH Weight:1931b Fr=10%
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30 *Except'
B1,B3: 2x4 SP No.2, 32: 2x4 SP No.3
WEBS 2x4 SP Nc.3'Except'
W3: 2x4 SP No.2
WEDGE
Right: 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 2-44 oc
purlins.
BOTCHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS
1 Row at midpt 4-13
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30 *Except'
B1,B3: 2x4 SP No.2, 32: 2x4 SP No.3
WEBS 2x4 SP Nc.3'Except'
W3: 2x4 SP No.2
WEDGE
Right: 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 2-44 oc
purlins.
BOTCHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS
1 Row at midpt 4-13
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
1490/0-7-10 (min. 0-1-12)
9 =
149010-7-10 (min. 0-1-11)
Max Horz
2 =
166(LC 11)
Max Uplift
2 =
-400(LC 12)
9 =
-400(LC 13)
Max Grav
2 =
1490(LC 1)
9 =
1490(LC 1)
FORCES. (lb)
.Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOPCHORD
2-3=-2649/1686, 3-4=-4340/2667,
4-5=-3153/1816, 5-6=3052/1841,
6-7=-3136/1856, 7-8=4315/2672,
R-g-::A678/2898__
BOTCHORD
2-16=-131612291, 4-14=-233/447,
13-14=2135/3999, 12-13=189713634,
11-12=190113609, 9-11=2479/4215
WEBS
3-16=1451/920,4-13=-1175/1004,
WEBS
3-16=1451/920, 4-13=-1175/1004,
7-13=8531776, 7-11=315/579,
8-11=337/439, 14-16=1566/2749,
3-14=720/1562, 6-13=-128612346
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vu11=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4'.2psf, h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces 8 MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise
indicated.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Bearing atjoint(s) 9 considers parallel to grain value
using ANSIFTPI 1 angle to grain formula. Building
designer should verify capacity of bearing surface.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 400 lb uplift at
joint 2 and 400 lb uplift at joint 9:
LOAD CASE(S)
Standard
mLv N-/N RGbE1Pl166E6 r6ELIF(Cf... r+ENERW 1EPH^ mq LVS(BpHb d15TMAEN yBIIYEti'4ACI'JaOVA.EOfi,PEKI-MR.VerE/haejnpwmbnminnl W-om AiTrm peyT O'm,O nW)'uM W'.
Ll�W
FE 6Y/b
QgemvpwgAly
R®.elEglnv Mw�u Mel Miw uw JMBiNWmMillR my:9¢a mmbor [1GeNeY,na.1 trinlW bb Wb N.ivm.FiT^®n4PR6N+eYE'rtlurf.Meulnv.YTDO eeeO�.m.
wilaik. clCw PN+�m^tlaGG,ier6ib4i6n"tlrvEn�We.C4T,rsNptlgm WT6O yvW iM.t.lW M14*".>w✓^PtrA W4^9vmG� vF.aNeINwJP.a TxakasirBWfMa Mmi6�+6�W M.
WGI�IBCiEs4nNe8mlcW iP1J:1Ti
.NRIBMIep
WMb Xwx EnO64�0 U91615
mue w.Wu,'MeB.�nAn6W4q.Oa9m'.neameaaW Sne+abw1M11eM P�M6deurWwTin?`x16n96+�Tti��a.w.meY6ab�W N.t-MxnuVnrt>p�Btivr
n.axrevnoee.nacmwu..w�a+mmnva'mBwecs.�sawv�e++=+w+..a+ma�aysTukNMtr�rs6enpt6caw�l�•b+Mmaa?66Aesnl„erc.ef..w�e�� mnnmw.aenywmn.ame...
atixMn+Tuunngm.swey E,gbeebtlrNwtlwtaxemrpeiuem�v T. h6d 6Tt�wJme eprnpypmp Mry'peNlevYae Nvoirot PRap.lehErymwttM0T6re 6WIryq o6w.r,rwTreK 6rhu Ee*e.WM9'�Ki�
S151 Wde 61A
aww.Rs.su
oW: 0fl2Y9ofe
YaGeYmtlsw erw6=e9ntrL6:Qgp�,llZ�16A9RM Tr.,[v.-liepalnMnp6vbgmu,M1PanY✓nn.%pGONM vliuC6a MM�NnuvnWMRarTnvv[`
JOb
Truss
Truss Type
Oty
Ply
A0280554
WRMSCM1560B1L
A08
ROOF SPECIAL
1
1
Job Reference (optional)
A-1 Hoot I misses, Fort Pierce, rL m4 , aesign(dalrmss.com
MUn:0.z1Us Mayla4Ularnnl:a.4lUeMayld ZUIa MneK
5x10 MT20HS=
6.00 12
6
3x6 G
5x6 G
5x6
5
7
4 W4
3x4 4
6
1.5x4 4
3
8
13
1
W2
6x8=
8
N
2
5
1°1 2
3
ax8s
17
3x8 MT20HS-
a
3.00 12
16 15
3x4 ¢
3x6 =
6x6 = 2x4 11
1-00--812I
9Vi1
38
776
I 7-1-4
9-1
Plate Offsets (X Y)—
17:0-3-00-3-01 19:0-0-10 Edgel
f14:0-5-8 0-4-81
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in (too)
Well
Ud
TCLL 20.0
Plate Grip DOL
1.25
TIC 0.69
Vert(LL)
0.46 11-13
>994
360
TCDL 10.0
Lumber DOL
1.25
BC 0.77
Vert(CT)
-0.88 11-13
>516
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.88
Horz(CT)
0.51 9
n/a
n/a
BCDL 7.0
Code FBC2017/rP12014
Matrix-MSH
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP 240OF 2.0E *Except*
B1: 2x4 SP No.2, B2: 2x4 SP No.3
WEBS 2x4 SP No.3 *Except*
W3: 2x4 SP No.2
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 2-7-13 oc
puriins.
BOT CHORD
Rigid ceiling directly applied or4-9-14 oc bracing.
WEBS
1 Row at midpt 4-13
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
1490/0-7-10 (min. 0-1-12)
9 =
149010-7-10 (min.0-1-8)
Max Hom
2 =
-165(LC 10)
Max Uplift
2 =
-400(LC 12)
9 =
-400(LC 13)
Max Grav
2 =
1490(LC 1)
9 =
1490(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
TOPCHORD
2-3=-2650/1686, 3-0=-4338/2666,
4-5=-3190/1839, 5-6=-3086/1861,
6-7=-3169/1875, 7-8=4314/2671,
8-9=4679/2899
BOT CHORD
2-16=1317/2292, 4-14=-235/447,
13-14=-213013992, 12-13=-1896/3634,
11-12=1899/3609, 9-11=-2480/4214
WEBS
3-16=1451/921, 4-13=-1132/971,
V-13=-817/745,7-11=315/578,
8-11=340/441, 14-16=-1567/2749,
WEBS
3-16>1451/921, 4-13=-11321971.
7-13=817/745, 7-11=315/578,
8-11=-340/441, 14-16=-1567/2749,
3-14=718/1558, 6-13=-1270/2322
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces 8 MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise
indicated.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-M wide will fit between the
bottom chord and any other members.
6) Bearing at joint(s) 9 considers parallel to grain value
using ANSVTPI 1 angle to grain formula. Building
designer should verify capacity of bearing surface.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 400 lb uplift at
joint 2 and 400 lb uplift at joint 9.
LOAD CASE(S)
Standard
Inc. IhUAU92213:41:082019 Page
iBLMVU Im7XJJalAIVOrpYh5lq?kAtylll
4-
Dead Load Deft. = 318 In
N
Q r'
IQ P
3x8
—i
PLATES
GRIP
MT20
244/190
MT20HS
187/143
Weight: 191 lb
FT = 10%
Job
Truss
Truss Type
Oty
Ply
w
A0280555
WRMSCM1560B1L
A09
ROOF SPECIAL
1
1
,
Job Reference (optional)
A -I Mool I Maass, ron rlerce, rL s4 b, oeslgn(a_ialvuss.com RUn:6.21U S May
3.6 =
20
6,6 =
6.00 F12 5x6=
19
2.4 II
1.5x4 II
7 85x6 /1
LOADING(psf)
SPACING-
2-M
CSI.
DEFL.
in (loc)
Well
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.78
Vert(LL)
0.45 15-17
>999
360
TCDL 10.0
Lumber DOL
1.25
BC 0.79
Vert(CT)
-0.82 17-18
>555
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.92
Horz(CT)
0.51 12
n/a
n/a
BCDL 7.0
Code FBC2017/rP12014
Matrix-MSH
LUMBER -
TOP CHORD 2x4 SP No.2 `Except`
T5: 2x4 SP M 30
BOTCHORD 2x4 SP 2400F 2.0E `Except`
B1: 2x4 SP No.2, B2: 2x4 SP No.3
WEBS 2x4 SP No.3 `Except`
W3: 2x4 SP No.2
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 2-2-0 oc
purins.
BOTCHORD
Rigid ceiling directly applied or 4-10-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be Installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (Ib/size)
2 =
1490/0-7-10 (min. 0-1-12)
12 =
1490/0-7-10 (min. 0-1-8)
Max Horz
2 =
-147(LC 10)
Max Uplift
2 =
-385(LC 12)
12 =
-385(LC 13)
Max Grav
2 =
1490(LC 1)
12 =
1490(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOPCHORD
2-3=-2654/1667, 34=4164/2502,
4-5=-4068/2516, 5-6=4195/2687,
8-9=-4018/2571, 9-10=-3952/2402,
10-11=4023/2384, 11-12=-4652/2817,
6-7=-3504/2089, 7-8=3504/2089
BOTCHORD
2-20=130012296. 5-18=-2531307,
17-18=-1364/3106, 16-17- 1344/3097.
15-1 6=-1 351/3078, 14-15=-2410/4200,
12-14=-2404/4184
WEBS
3-20=13911874, 6-17=-369/956,
8-17=3931974, 8-15=789/936,
WEBS
3-20=-1391/874, 6-17=-369/956,
8-17= 393/974, 8-15=789/936,
18-20=153112723, 3-18=-591/1396,
6-18=-876/1043, 9-15=-306/346,
11-15=575/572
NOTES- .
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. 11; Exp B; Encl.,-GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) All plates are MT20 plates unless otherwise
indicated.
5) This truss has been designed for a 10.0 psi bottom
chord live load nonconcurrent with any other live
loads.
6) `This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
7) Bearing at joint(s) 12 considers parallel to grain
value using ANSIrrPI 1 angle to grain formula.
Building designer should verify capacity of bearing
surface.
8) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 385 lb uplift at
joint 2 and 385 lb uplift at joint 12.
LOAD CASE(S)
Standard.
Inc. InUAUg L213:41:102U19 Page
:IoS9EyLSo7rTMJh7HRgOA8UgFmyll7
40
d 1 -
Dead Load Deft. = 7/16 in
US
PLATES GRIP
MT20 244/190
MT20HS 187/143
Weight:2041b FT=10%
Jobs
Truss
Truss Type
Qty
Ply
A0280556
=Rf,,,n,
WRMSCM1560B1L
A10
Hip
1
ona0
A-1 Hoot Irusses, rort Fierce, rL 34 b, Oestgn(w_a1 Wss.com
Hun: ti.[1u s May 16 2u16 Firm: a.ZIu s May 18 2018 MiTek Industries, Inc Thu Aug 22 13:41:112019 Page 1
ID:Id_00XyyT61Bl_TXo1jwHHzefvK-ps6VbU WaTGJVMyl LofthLDNfJj2fOxCYPODOnCyI I76
14A-1
1 ]39 11-10-12 1 4-0 19-0-0 23-3-15 25A-0 2&7A 317-1 38-0-0 p9d0
01V 7-3-9 4-7-2 0.5-I424-0 4-3-15 i 4-3-15 i 2-0-0 2-11-9 2-11-9 i 64-15 Y1�A—
5x6 11
3.6 =
6.00 12
20
4.6 =
19
2x4 II
1.5x4 11 5x6 //
7-3-9 1 11-10-12 , 14-8-1 , 19-0-0 1 23315 , 25-8-0. 31-7-1 38-0-0
Dead Load Defl. = 71161n
3x8 m
7-3-9 14-7-2
12-9-5 4-3-15
4-3-15
24-0
5-11-2
64-15
Plate Offsets (X,Y)-
T4:0-3-0,Edgel, 19:0-3-0,0J-01.
111:0-0-10,Edgel, T18:0-54,Edgel
LOADING(psf)
SPACING- 2-M
CSI.
DEFL.
in (loc)
Udell
Lid
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.77
Vert(LL)
0.49 16
>940
360
MT20
244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.76
Vert(CT)
-0.88 , 16
>516
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.71
Horz(CT)
0.56 11
n/a
We
BCDL 7.0
Code FBC2017/TP12014
Matrix -MS
Weight: 202 lb
FT = 10%
LUMBER -
TOP CHORD 2x4 SP M 30'Except'
T2,T1: 2x4 SP No.2
BOT CHORD 2x4 SP 2400F 2.OE *Except*
B1: 2x4 SP No.2, B2: 2x4 SP No.3
WEBS 2x4 SP No.3 *Except*
W3: 2x4 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-4-14 oc
purins.
BOTCHORD
Rigid ceiling directly applied or 4-10-12 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erec0on, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
1490/0-7-10 (min. 0-1-12)
11 =
1490/0-7-10 (min.0-1-8)
Max Hoe
2 =
-131(LC 10)
Max Uplift
2 =
-371 (LC 12)
11 =
-371 (LC 13)
Max Grav
2 =
1490(LC 1)
11 =
1490(LC 1)
FORCES. (Ib)
Max. Comp./Max. Ten. - Al forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-2665/1655, 34=4180/2468,
4-5=4099/2483, 5-6=3712/2217,
6-7=-4761/2730, 7-8=4761/2730,
B-9=-3782/2189, 9-10=4541/2886,
10-11=4651/2765
BOT CHORD
2-20=129412309, 5-18=-252/353,
17-18=-190713788, 16-17=1544/3375,
15-16=-154713396, 14-15=1555/3382,
13-14=-2203/4032, 11-13=2365/4179
WEBS
8-20=1336/842, 18-20=1512/2693,
7-16=269/219, 3-18=-565/1382,
WEBS
3-20=-1336/842, 18-20=-1512/2693,
7-16=269/219, 3-18=565/1382,
6-17=343/474, 8-14=261/455,
6-16=858/1772, 8-16=-846/1745,
9-14=-614/629, 9-13=-253/304;
5-17=-520/466
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult-160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. It; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exumor(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces 8 MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcument with any other live
loads.
5)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Bearing at joint(s) 11 considers parallel to grain
value using ANSI/TPI 1 angle to grain formula.
Building designer should verify capacity of bearing
surface.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 371 lb uplift at.
joint 2 and 371 lb uplift at joint 11.
LOAD CASE(S)
Standard
yvgglSy 'A.I AOJFTd156E5(6ftlPi'l,.'AENEyt iFpx6 nq GpraR0.W64U6TOYERjHWFA�iCR:W1t£OGYEvfI-.(mR VwIIY Nspnpp��^^����nnaW,u1 T,m
41mw. VnMLLrnnCvgmtl W140. YAN'Pv ieOOvv+Gee sCY PeI® bVekQNalwPTLTE�MrTV 6 L^vT MvnB IAL1vNm
Q
JVW BdmnVPE8bH08
-W%ENno,Naiv,1,W A.
vvega,ra dYa A+ti Y^8a^n^Bn,paN„y b,MOcv6nd4^ Pyy 1[IOm TNf Ilia �mTw@Lx. WPcrtlemC�ba WNN atlwJiWMb'i ml.NMtlm ���, .n2�^m u,.
^ uWv
Oa*w,VaO^®avMav]yn eAa6�.iVi®.bJprr,AyaemfeEy WgC,¢a T ) MBuNag dvpW4N.
-ivYtiN?R
Wm4 H0uM EnpMevMp LB91615
atl Pl4TNVaW IIY� YWmemOaTt�^i:��rBaiNra^C^i��l^4 rA4br�Ortl-tia4NYtlnaapu?v/Yi
cfAgygONaAarebC �d NMrsN a4FinaT®WMR�aewtlBMeM1¢aAPV Bu16nb�Ti �l �rY»�-9p��M]h'iRNf�AwnMxeGAW,^9u[artF® bMwMere`i�>«a wO
O+IiYNlgTrvm Cny�.SPmiIY Fry,vmtl irys 4aMa0mr.6NnYo]unN,pryyyylCmYaRgrealyyp,n^My LYY ivmamd,W iM 6,'rnly Eryiaa,atlpt MBA4pMs{,vnTry 6yNVEiB(�av1^,y SWyq-fA
NS, S,IWVB,M.
RRup.FL 31918
OAa 6YdL%B
..
ivWtivat h,mienabtM rttKf'(.Wp V]CAf60.1 M2TJuvua-RryreCv[MnNOrsderwA ®+q fvm, i,pMLM1^T,wf W a.fMfwnnhrw,<fAA livRT^anm.
Job
Truss
Truss Type
Ory
Ply
A0280557
WRMSCM1560BlL
All
Hip
1
1
Job Reference (oo8ona0
A-i KooT I russes, tort tierce, I-L 34846, aesignLwaltruss.Lem
o�
6x6 =
Kun:a.2lus May la2ul8Knnt: 62lu a Mayl62u16MI1eK
4x4 =
5
5x8 = 2x4 11 4x4 = 6x6 =
6 7 8 9
Inc. I OU AUa ZZ 1J:41:11 ZU1s
ZZ _. Zu _- __ le 111
3x6 = 1.5x4 11 3.6 = 3.8 = 6.8 = 2.4 11 4x8
LOADING(psf)
SPACING-
2-M
CSI.
DEFL.
in
(Joe)
Udell
L/d
TCLL 20.0
Plate Grip DOL
I fi
TC 0.30
Vert(LL)
-0.41
18
>999
360
TCDL 10.0
Lumber DOL
1.25
BC 0.31
Vert(CT)
-0.76
18
>598
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.75
Horz(CT)
0.45
12
n/a
n/a
BCDL 7.0
Code FBC20171TPI2014
Matrix -MS
LUMBER -
TOP CHORD 2x4 SP 2400F 2.OE'Except'
T2: 2x6 SP 2400F 2.0E
BOT CHORD 2x4 SP 2400F 2.oE *Except*
84,135: 2x6 SP 2400F 2.0E
WEBS 2x4 SP M 30
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 3-6-8 oc
purins.
BOTCHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS
1 Row at midpt 6-19
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
1490/0-7-10 (min. 0-1-8)
12 =
1490/0-7-10 (min.0-1-8)
Max Hom
2 =
-114(LC 10)
Max Uplift
2 =
-354(LC 12)
12 =
.354(LC 13)
Max Grav
2 =
1490(LC 1)
12 =
1490(LC 1)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOPCHORD
2-3=-2704/1665, 3-4=-2179/1418,
4-5=-1888/1354, 5-6=207111463,
6-7=-5615/3204, 7-8=-564913220,
8-9=-3715/2225, 9-10=-4103/2393,
10-11=4749/2981, 11-12=4790/2830
BOT CHORD
2-22= 1318/2354, 21=22=131812354, - —
20-21=l318/2354, 20-29=102512077,
29-30=1025/2077, 19-30=-1025/2077,
16-17=-2319/4733, 15-16=-2146/4089,
14-15=-2151/4070, 12-14=-2428/4338
WEBS
3-20=-555/495, 4-20=-415/734,
WEBS
3-20=555/495, 4-20=-415i734,
9-16=955/1705,11-14=-236/311,
6-19=3795/1935,5-20=-531/268,
8-16=1713/913, 8-17=-788/1576,
17-19=-2124/4332, 6-17=253115150,
10-14=407/418,10-16=-364/388
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed, and vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
pending.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-M wide will fit between the
bottom chord and any other members, with BCDL =
7.Opsf.
6) Bearing atjoint(s) 12 considers parallel to grain
value using ANSIRPI 1 angle to grain formula.
Building designer should verify capacity of bearing
surface.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 354 lb uplift at
joint 2 and 354 lb uplift at joint 12.
LOAD CASE(S)
--Standard —
Dead Load Dab. = 3181n
.S
12 1313
PLATES GRIP
MT20 2441190
Weighl:2461b FT=10%
Jobt
Truss
Truss Type
Oty
Ply
A0280558
WRMSCM1560BlL
Al2
Hip
1
1
Job Reference (optional)
A-1 Koof I nlsses, tort Fierce, rL 34a4a, oesa]n(w_atrmss.com
yI1
o,
3.6 =
5.8 =
nun: a.ztu s may to zum Fnm: mz1u s
4x4 = 5xl2 = Sx6 = 5.6 = 5x8 11
zl -- 19 15 17
3x4 = 3x6 = 5.8 = 3x4 II
3x4 =
Inc. Thu Aug 22 13:41:12 2019
11-0-0 14$3 18-2-9 21-5-3 24-0-13 27-0-(I 32$i 38-0-0
11-0-0 3-8-2 3-6-6 3-2-10 2-7-11 2-11-3 112 .1e-15
Dead Load Deft. = 7/161n
4.8
Plate Offsets (X.Y1-
14:0-2-0,0-Ml.16:0-3-8,0-2-121,(11:0-2-11,0-0-101.114:0-2-8,0-4-121.116:0-3-15-Edoel
(18:0-1-12 0-1-81
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
Wet
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.54
Vert(LL)
0.53
16
>853
360
MT20
2441190
TCDL 10.0
Lumber DOL 1.25
BC 0.45
Vert(CT)
-0.98
16
>466
240
MT20HS
1871143
BCLL 0.0 '
Rep Stress nor YES
WS 0.80
Horz(CT)
0.51
11
n/a
We
BCDL 7.0
Code FBC2017/TP12014
Matrix -MS
Weight:249Ib
FT=10%
LUMBER -
TOP CHORD 2x4 SP N0.2 *Except*
T2: 2x6 SP 2400F 2.0E
T3: 2x4 SP 2400F 2.0E
BOT CHORD 2x6 SP 240OF 2.0E *Except*
B1,132: 2x4 SP 2400F 2.0E
WEBS 2x4 SP 240OF 2.0E
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 3-2-6 oc
purins.
BOT CHORD
Rigid ceiling directly applied or 5-10-9 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
148910-7-10 (min. 0-1-8)
11 =
1489/0-7-10 (min.0-1-8)
Max Horz
2 =
-101(LC 10)
Max Uplift
2 =
-340(LC 12)
11 =
-340(LC 13)
Max Grav
2 =
1489(LC 1)
11 =
1489(LC 1)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOPCHORD
2-3=-267911701, 34=-2317/1457,
4-5=-2313/1576, 5-6=2441/1644,
6-7=-8194/4589, 7-8=8739/4865,
8-9=-5950/3417, 9-10=-4394/2519,
10-11=-4821I2858
BOT CHORD
2-21=1364/2361, 20-21=-978/2009,
19-20=-978/2009,18-19=-1181/2310,
7-16=112/324, 15-16=-3099/6097,
14-15=-1994/3989, 13-14=-2490/4410,
11-13=-2470/4374
WEBS
3-21=408/447, 4-21=-127/439,
WEBS
3-21=408/447, 4-21=-127/439,
6-16=3226/6301, 6-18=-3066/1648,
16-18=1859/3630, 8-15=-185611014,
9-1 5=1 346/2562, 9-14=-154/304,
10-14=-433/470, 8-1 6=-1 630/3138,
5-19=519/301, 5-18=-132/308,
4-19=368/637
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Extedor(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces 8 MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) All plates are MT20 plates unless otherwise
Indicated.
5) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
6)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
7) Bearing at joint(s)11 considers parallel to grain
value using ANSI/TPI 1 angle to grain formula.
Building designer should verify capacity of bearing
surface:
8) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 340 lb uplift at
joint 2 and 340 lb uplift atjoint 11.
LOAD CASE(S)
Standard
Job
Truss
Truss Type
qty
Ply
A0280559
WRMSCM1660BlL
A13
Hip
1
1
Job Reference o tional
A-1 Roof Trusses, Fort Pierce, FL 34946, deslgn@attnlss.com
Run: 8.210 s May 18 2018 Print: 8.210 a May 18 2018 MiTek Industries, Inc. Thu Aug22 13:41:13 2019 Page 1
ID:ld_OOXyyT61Bl_TXo1jwH RzefvK-IEEFOAY(tuZDCFBkv4v9QeT5yWgrUsBgs6iUs5ylI74
B-0-0
1 4-P15 71-] 1i 13 7 1 2 1)-5-9 15-48 W4, 15.3A 29-0-0 We We
f1-0.0 4015 33e 4-0-) 9 3 3aA 1-11-0 48125 1-6 3-&12 4.40 560
4)-9
6z6 4
6.00 12 3" 14 5
Us =
1.5x4 11 3.6 = 1.5z4 11 6z61
6 7 8 9 3.4 =10 11
4
3x4 1
3.4 O
12
1
0
4
S
1
2
7��
3
26
25 24
32 31 29 28
20 21 19
18 17 t6
15
Us = 44 = 1.5.4 11
48= 2x4 II 23
2x4 II 3x6 II
48 = 3.6 =
1.5x4 II
Us _
3x4 =
5x8 =4x4 =
7x8 =
2x4 11
2z4 II
3x4 II
9.0.0
B 7
196.021-63
4A15 7-0-) 2-15 134-7
175 19Sb2pr�..gq 2534
11-1
29-0-0 33b0
3800
4-0.15 316 0.16a�1
41.0 111 1 3J-0
3A-12 4-00
I SDO
�
0.141
0-141 1d12
n 7.Q
Plate Offsets (X,Y)-
f5:0-1-12,0-1-121.111:0-1-12,0-1-121.f21:0-2-4,0-4-41,
f30:0-5-12,0-2-81
LOADING(psf)
SPACING- 2-0-0
CSI.
DEFL
in (loc)
I/defi
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.37
Vert(LL)
0.06 15-38
>999
360
MT20
244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.33
Vert(CT)
-0.07 28
>999
240
BCLL 0.0 '
Rep Stress Incr YES
WB O.68
Hom(CT)
0.02 13
n/a
n/a
BCDL 7.0
Code FBC2017ITP12014
Matrix -MS
Weight: 2481b
FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2 *Except*
B2: 2x6 SP No.2, B3: 2x4 SP Nc.3
WEBS 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 5-3-14 oc
pudins.
BOTCHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
73410-7-10 (min. 0-1-8)
19 =
1771/0-7-10 (min. 0-2-1)
13 =
482/0-7-10 (min. 0-1-8)
Max Horz
2 =
-85(LC 10)
Max Uplift
2 =
-202(LC 12)
19 =
-710(LC 9)
13 =
-007(LC 8)
Max Grant
2 =
750(LC 23)
19 =
1771(LC 1)
13 =
512(LC 24)
BOTCHORD
2-32=425/1015, 27-30=-176/714,
26-27=265/913, 25-26=147f790,
24-25=-401378, 22-24=-40/378,
21-22=0/283,18-19=423/370,
16-17=-732/512, 15-16=-732/512,
13-15=732/512
WEBS
19-21=-1709/1450.11-17=-483/278,
5-26=2'10/369, 30-32=-330/800,
12-17=-394/630, 6-25=-272/233,
5-25=-261/202, 7-25=4847733,
7-21=1130/680, 10-18=535/392,
18-21=-232/267, 10-21=-858/1012,
11-18=512/546
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCOL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed; porch right
exposed;C-C for members and forces 8 MWFRS for
reactions shown; Lumber DOL=1.60 plate gdp
DOL=1.60
3) Provide adequate drainage to prevent water
FORCES. (lb)
pending.
Max. Comp./Max. Ten. -All forces 250 fib) or less except
4) This truss has been designed fora 10.0 psf bottom
when shown.
chord live load noncencument with any other live
TOP CHORD
loads.
2-3=-1180/643, 3-4=-1059/566,
5)' This truss has been designed for a live load of
4-5=-889/511, 5-6=610/338,
20.Opsf on the bottom chord in all areas where a
6-7=-610/338, 7-8=526/809,
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
8-9=-526/809, 9-10=518/800,
bottom chord and any other members.
10-11=0/251, 11-12=-261/541,
6) Provide mechanical connection (by others) of truss
12-13=-625/957
to bearing plate capable of withstanding 202 It, uplift at
—BOT-CHORD- - - --- - - - -- —Joint
2, 710 lb uplift at jo) int 19 and 307 Ile uplift at joint
2-32=-425/1015 27 30= 1767714
13. T
26-27=-265/913, 25-26=-1471790,
24-25=-40/378, 22-24=-40/378,
21-22=0/283, 18-19=-423/370, LOAD CASE(S)
16-17=732/512,15-16=-732/512, Standard
Job 1
Truss
Truss Type
Oty
Ply
A0280560
WRMSCM156OBlL
A14G
Hip Girder
1
1
Job Reference (optional)
A-1 Roof Trusses, Fort Pierce, FL 34946, design@albuss.com
3x6 =
4x4 =
-- -- 25
3x6 II
5x8 =
2x4 II
3x4 II
4x10 =
Run: 8.210 s May 18 2018 Print: 8210 s May 18 2018 MiTek
1.5x4 It
21 ._ - 52 53 1b --b4 bb
3x4 II 3x6 II 5x6 =
2x4 11 8x12 =
3x8 =
Inc. Thu Auq 22 13:41:14 2019
Bd8 19515 21d-3
6-2-14. 11-11-15 13-10.7, 16-10.1 15A] a0J-� 28312 28rt-2 31-0-0 38-0-0
4-0-0 309 2-1 0.78 1-1068 2-11% 2-66 0. -8 1 4-]A b ]
0.1-8 0.108
Dead Load Defl. = 1181n
34 =
Plate Offsets (X Y)-
14:0-1-12 0-1-121 110:0-3-0 0-2-01 116:0-0-0A-1-121
116:0-2-0.0-3-01.119:0-4-0.0-0-41 127:0-5-12,0-2-121.
129:0-2-0,0-1-81
LOADING(psf)
SPACING- 2-"
CSI.
DEFL.
in (loc)
I/deft
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.98
Vert(L-)
0.13 23-24
>999
360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.66
Vert(CT)
-0.2223-24
>999
240
BCLL 0.0 '
Rep Stress Incr NO
WB 0.72
Horz(CT)
0.07 12
n/a
nla
BCDL 7.0
Code FBC2017/TP12014
Matrix -MS
Weight:229lb FT=10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2 *Except'
B2: 2x6 SP No.2, B3: 2x4 SP No.3
WEBS 2x4 SP No.3'Except'
W8: 2x6 SP No.2
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 3-0-7 oc
purins.
BOTCHORD
Rigid ceiling directly applied or 5-2-13 oc bracing.
WEBS
1 Row at midpt 6-19, 9-19
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (Ib/size)
2 =
1304/0-7-10 (min. 0-1-9)
17 =
3893/0-7-10 (min. 04-9)
12 =
745/0-7-10 (min. 0-1-8)
Max Horz
2 =
-69(LC 6)
Max Uplift
2 =
-452(LC 8)
17 =
-2047(LC 5)
12 =
-582(LC 4)
Max Grav
2 =
1310(LC 19)
17 =
3893(1-C 1)
12 =
756(LC 20)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOPCHORD
2-3=2379/815, 34=-2603/924,
4-36=2318/846, 36-37=-2318/846,
5-37=2318/846, 5-38=-2318/846,
38-39=2318/846, 6-39=-2318/846,
640=-925/2049, 4041=-925Y2049,
741=925/2049, 7-8=-932/2058,
842=932/2058, 942=-932/2058,
1J43=-832/917, 4344=-832/917,
1044=8321917, 10-11=-972/996,
Continued on page 2
TOPCHORD
2-3=-2379/815, 3-4=26031924,
4-36=2318/846, 36-37=2318/846,
5-37=2318/846, 538=-2318/846,
38-39=2318/846, 6-39=2318/846,
6-40=-925/2049, 40-41=-925/2049,
7-41=925/2049, 7-8=932/2058,
8-42=932/2058, 9-02=-932/2058,
943=-832/917, 43-44=-832/917,
10-44=832/917, 10-11=-972/996,
11-12=-1182/1050
BOTCHORD
2-29=-716/2082, 28-29=-120/292,
24-27=706/2154, 2445=-791/2353,
45-46=791/2353, 23-46=791/2353,
2347=100/691, 4748=-100/691,
2248=1001691, 22-49=-100/691,
20-49=1001691, 20-50=-156/901,
19-50=-156/901, 17-52=-11091496,
52-53=11091496, 16-53=-11091496,
15-16=-1109/496, 15-54=-371/40,
54-55=-371/40, 1455=-371I40,
12-14=-894/1022
WEBS
17-19=3653/1872, 7-19=-497/314,
27-28=33/415, 4-27=-135/692,
5-23=594/362, 6-22=0/295,
6-23=-786/1893, 6-19=-3163/1277,
9-15=-220/319, 15-19=-853/1137,
9-19=2382/1577, 3-29=-374/165,
27-29=610/1832, 3-27=-2631355,
9-14=-567/1025
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=1511;
Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; porch right exposed; Lumber DOL=1.60
plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) ' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 452 lb uplift at
joint 2, 2047 lb uplift at joint 17 and 582 lb uplift at joint
12.
7) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 239
lb down and 249 lb up at 7-0-0, 106 lb down and 116
lb up at 9-0-12, 106 lb down and 116 lb up at 11-0-12
, 106lb down and 116 lb up at 13-0-12, 106 lb down
and 116 lb up at 15-0-12, 106lb dawn and 116 lb up
at 17-0-12, 106 lb down and 116 lb up at 19-0-12.
118 lb down and 129 lb up at 21-0-12, 44 lb down and
71 lb up at 22-11-4, 44 lb down and 71 lb up at
24-11-4. 44 lb down and 71 lb up at 26-11-4, and 44
lb down and 71 lb up at 28-11-4, and 152 lb down and
194 lb up at 31-M on top chord, and 311 lb down
and 69 lb up at 7-1-12, 84 lb down and 21 lb up at
9-0-12, 84 lb down and 21 lb up at 11-0-12. 84 Ito
down and 21 lb up at 13-0-12, 84 lb down and 21 lb
up at 15-0-12, 84 lb down and 21 lb up at 17-0-12, 84
lb down and 21 lb up at 19-0-12, 77 lb down at
21-0-12, 145 lb down and 139 lb up at 22-11-4, 145lb
down and 139 lb up at 24-114, 145 lb down and 139
lb up at 26-114, and 145 lb down and 139 lb up at
28-114, and 399 lb down and 393 lb up at 30-114 on
bottom chord. The design/selection of such
connectiondevice(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 14=60, 4-10=60, 10-13=60, 26-30=14,
25-26=-14, 20-24=-14, 18-21=14, 18-33=-14
Concentrated Loads fib)
Job
Truss
Truss Type
Qty
Ply
A0280560
WRMSCM1560BlL
A14G
Hip Girder
1
1
Job Reference o Oonal
A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MTek Industries, Inc. Thu Aug 2213:41:14 2019 Page 2
ID:Id_OOXyyT61Bi_TXoljwHHzefvK-DOoeD W YfmBh4DPmwToOOz(16Dw5zDHJ_5mS2OXyli73
LOAD CASE(S)
Standard
Concentrated Loads (lb)
Vert: 4=-192(B) 8=31(121)10=-105(B) 28=-311(B)
14=399(B) 22=73(B) 6=-106(B) 36=-106(B)
37=-106(B) 38=106(B) 39=-106(B)40=-106(B)
41=l 18(B) 42=-31(B) 43=-31(B) 44=31(B) 45=-73(B)
46=73(1]1) 47=73(B) 48=-73(B) 49=73(B) 50=-56(B)
52=145(121) 53=145(B) 54=145(B) 55=-145(B)
QMaa9imirH.mrvtu LtljWF1F(95E6(fiEfL�.GelFfNl IEnMBaYCam111pXS W6rONEa {{66NN''EFAR11MRiaVREWYET+I"tmwv+M 6� 4m�'MenpYmO wafmEtl.inm MSH^MwhW IrBCIw ue
6A�M FgInF�mM+tlaYe;wc UnbfaM�.MW B1m0. m6[P'pn9m'raYm aaMµUB WtmJbMTBBbAVW, eaelxn PaV^�c'YmPYD46N+%EM^�). PmeW me^IT06,mmmieu,. JeielBdnlry PE6]fifB .
c�mSpprabtm.Yvpa�60�mvNhbPlOia�dM.a;aTum bp'cW mASTM m1ywTq.].lMOee{+mm:Ru; 6aGayemCSen� WaNfi)N,sJNsT be,)BdJm&vYvgryvv}3rydM VrMb1NUA6glppNq C�91815'.
MO+MvNm.NbrtmMBvKp Bny.�r.AMmwEdErCl4NIBCylmlpVlipma mi Rev ll+iypeNdMl➢Bw]ppMNvsdMTtm;aeWglwYu6.�,mym n9yiym�adp.cngy,epbUsrtapRSiMy: YSIp4ti0BM.
MMdMMDe+bm/sE CL�W�Hm P4miei'iNm9NM'IW WMpmpyTb�pmmm4o��.�qaad➢w BuiGnjY00ATYSLt�1Pb^retlmSBBN.WNYTI MTPImJEH'.J,`w rtanKMAifm�mPWlmte lPFT2elMNentRc�YiY3Oimp FL MPo.R9I9,6
Yc6r N68Trvw Cw4�.$4'd+�b BrysaimdTN®MeM.Mt,nNw.eunmMrGekMQ8l tCounaa�«EUWn+iwCNMNPtlmei�,d.vl�nvamwWOyviw,a M1roTM BW+a atW!aTrvn6rM��iNs,.UmnS��P,R4 Bma 4YLveMB ''
'ceWNiJymeNb6aM.n'!PN'Cglp�aC]0164t0.b Twee-RmwmmNtlem..NemintmryMn,;pcA1We]�sYM�m m.[d 0.1RxfTrv¢¢'
Jobs
Truss
Truss Type
Qty
Ply'
A0260561
WRMSCM1560BIL
B01G
Hip Girder
1
1
Job Reference o Oonal
A-1 Roof Trusses, Fort Pierce, FL 34946, design@attwss.com
Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MTek Industries, Inc
.oad Defl. = 1/16 in
3x4 = 1.5x4 II 4x4 = 3x4 = 46 =
LOADING(pso
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.80
Vert(LL)
-0.11
6-8
>999
360
MT20 2441190
TCDL 10.0
Lumber DOL
1.25
BC 0.93
Vert(CT)
-0.20
6-8
>999
240
BCLL 0.0
Rep Stress Incr
NO
WB 0.23
Horz(CT)
0.07
5
n/a
We
BCDL 7.0
Code FBC2017/rP12014
Matrix -MS
Weight: 81 lb FT = 10%
LUMBER -
TOP CHORD 2x4 SP M 30 *Except*
T3: 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
WEDGE
Right: 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 2-9-1 oc
puriins.
BOT CHORD
Rigid calling directly applied or 6-7-1 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
5 =
1389/0-3-6 (min. 0-1-10)
2 =
145410-7-10 (min.0-1-11)
Max Horz
2 =
80(LC 8)
Max Uplift
5 =
-075(LC 9)
2 =
-502(LC 8)
Max Grav
5 =
1389(LC 1)
2 =
1454(LC 1)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
TOP CHORD
23=2594/887, 3-15=-2196/826,
15-16=2196/826, 4-16=-2196/826,
4-5=2535/868
BOTCHORD
2-8=-763/2244, 8-17=-763/2264,
17-18=-763/2264, 7-18=-763/2264,
6-7=-763/2264, 5-6=-702/2177
WEBS
3-8=-7/601, 4-6=7/578
NOTES-
ti) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpl=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nommncument with any other live
loads.
5) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 4751b uplift at
joint 5 and 502 lb uplift at joint 2.
7) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 239
lb down and 249 lb up at 7-0-0, 118 lb down and 129
lb up at 9-0-12, and 118lb down and 129 Ito up at
10-3-4, and 239 Ito down and 249 lb up at 124-0 on
top chord, and 311 lb down and 69 lb up at 7-0-0, 77
Ito down at 9-0-12, and 77lb down at 10-3-4. and 311
Ito down and 69 lb up at 12-3-4 on bottom chord. The
design/selection of such connection devim(s) is the
responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof. Live (balanced): Lumber Increase=1.25-
, Plate Increase=1.25
Uniform Loads (pit)
Vert: 1-3=-60, 3-4=-60, 4-5=-60, 9-12=14
Concentrated Loads (Ib)
Vert: 3=192(B) 4=-192(B) 8=311(B) 6=311(13)
15=-118(B) 16=118(B) 17=-56(B) 18=-56(B)
'>.I R05 TW166FS ('i11ER14EN �lE?Msuq CWN110Y3N6T0lIEPj�Y�}A4%fNWLE6GNalPM VnM'�'O�p�stl rttinNamMirvv OaaP�^A^B(Im)aneM
JarWBounhGPE 63906
QRsuew9�HmY+
64vY%ERIi�,N ^9 ^�Tlte(ww�MYeWr-�oYMYp. TOo: wh4L',NN!'�eeSwebl�i Au1 ,wOWMlWbpvIDq �Yuuo-sg^£iY^n,lip Ne6iTaAYE�i�'m1 PavWm ^It00 lePv?m4an
gryu,ae(4uY +�mYmPr4��R;�'A14WFiN,4�N� YP+�mOv TOemN v�tle]RiTMJ�G^avw+4*YA�4^Gmb�fcm,NnL)vdwNlbi�mbMg!�flP�ruM?1'tl4M.
WIeLWUSe rMMWyG31816
�S�I
Aec,nO�w/i Wucedq® BWti9=1^T�AMm.,ddW W1i9uEOmCTPLtbv 91 ^�^rJbslW mMhN�e,dWTtm.w�31�^3As®A. �,5Y6,lt,Nbna'ArnYlb WvayNnW
Y5194Nr &Y.
r+^m^G6�wmw Grtnw, N z et i�Wttneuv+wb Y��va Alne ndl'a.T+Trativrenemmmyesrq ptlWnl%TMW£BCRaronMevMwGvaw9Ww. PL4hID.nmeveiv'tlKUL?^a
ft Rau.R9T916
'tlul%MMTrvw0.,V�er.?f+m6 EN Oi616N4Try 4YMabvf.eiYel oTMe,9,Gre1M�Eminn9!eK.Kmi,vO.TGMdVM��M�MC�ii$6P>bEMmR/tlhViM&ibv90e!S�N,v1rvn6M �Exi^r[fIMF1itlQe4;M
.�WMa'�1bm�,nenhLmChTCL I.Cm)W�SM1 Pu%Trvsv�-f<MwF¢OmNOUJa[ve'A,LAmMImaA [vA�4s5PmYtiv wNenp�v.navaMR1 PMTms¢
09e 0Y1NOtB
Job
Truss
Truss Type
Dry
Ply
A0280562
WRMSCM1560BlL
B02
Hip
1
1
r'
Job Reference (optional)
A-1 Roof Trusses, Fort Pierce, FL 34946, design@attruss.com Run: 8.210 s May 18 2018 Print 8.210 s May 18 2018 MiTek Industries, Inc. Thu Aug 22 13:41:16 2019 Page 1
ID:Id_0OXyyT6181_TXo1jwHHzefvK-9pwOeCajlpynTjwJbCSs2G4XrkiahKGHY4x9TOyl I71
10 4-0
-1-0-0 9-0-0 9-e-0 18-11-12
1-4-0 I 9-0-0 8.7-12
a-"
4x6 1.5x4 11 Dead Load Deb. = 31161n
4x6
�7
4x4 =
6.00 F12
5x6 =
LOADING(psf)
SPACING-
2-M
CSL
DEFL.
in
(too)
I/deft
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.65
Vert(LL)
-0.25
7-13
>929
360
TCDL 10.0
Lumber DOL
1.25
BC 0.82
Vert(CT)
-0.43
7-13
>525
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.14
Horz(CT)
0.02
6
n/a
n/a
BCDL 7.0
Code FBC2017frPI2014
Matrix -MS
LUMBER -
TOP CHORD 2x4 SP M 30 *Except'
T2: 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
WEDGE
Right: 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 5.3-0 oc
pudins.
BOTCHORD
Rigid ceiling directly applied or 6-11-6 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
6 =
69910-3-6 (min. 0-1-8)
2 =
78910-7-10 (min. 0-1-8)
Max Hom
2 =
95(LC 12)
Max Uplift
6 =
-176(LC 13)
2 =
-215(LC 12)
Max Grav
6 =
699(LC 1)
2 =
789(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
TOPCHORD
2-3=-1012/619,3-4=806/675,
4-5=-806/675,5-6=1017/622
BOTCHORD
2-7=-394/806, 6-7=.394/806
WEBS
4-7=-8/372
—NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf, BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and night
exposed ; and vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcument with any other live
loads.
5) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-" wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 176 Ib uplift at
joint 6 and 215 lb uplift at joint 2.
LOAD CASE(S)
Standard
to
46 =
PLATES GRIP
MT20 244/190
Weight: 69 lb FT=10%
QWm'Mwp„H WN`Lf ADGlF1136Ebt'it1Fq`}4ENFJU4 TcN,IS aq Cd90RAN6CU$TOMER[6W6t-10.fIRNQMEBt.4tlIPMmVSRj6nynpvuN,osamYaN�T qp T,uNq,g, WavE m
GaN%E/Cnezmbmoelm(t'Jvm ip.lfilmcTwW M�]mtYlW: a'0.'?BwnmaoroMRWuavG iw MTW bAMe N�TwN CoPETF^aV Oa'bk °p'tnG^a�l,4+wlmv'! « 1ve1BOWNPE6e�
ryyTlyoaApMabmlwAimih6(Y OfYegntlp�pgYSw Yp4 mpnlppgy �brN.t.��6w'g.mT� 44<W �a �=.N9N19Y��alM irva\m vj&Ma,p4P�gm�4.W tlM tNN91WNF�gCealy G91615
o..m,v.o.r.wa,ma. aa�ImxeWlrvdWm.ne.mmao.wCa..le:br.>+ccwe.alvN.11:w+*+\aw Too.n.,rru,e.awT��aaw�aq:. •,manwuv.pww,am.aewese.mpemNr• usl sluw®w.
Nda BoC0.WiM WbWm NmartelaMgNNe vEN�t6}amW GmN9�MMBa1n8�M?aFY4RmWu169�C^bYYf]4/r%Od6BLrim RMarMb�ntia9afap� iV!'\49�aPemtaWBS?✓A- RRerte. fLNM9
prtwam ,uaWy�ei,6p✓a- IIrE�MT,m dwulalm\,bNn�tl,m'ue ®fiigC 6y 0.LaJnC-giplupaFMNq 61Wp=F, MebW.TN6yw�Enpi.;ntq WTMB l6q VBeµa,ImiNa syq}ai E�gPFelary QwWy M: Bab: 0621Rp19
[a0.WPMbnumcdamCFiWi OnygNO'A1841 hxSLtiaa-p�pofbvOonMYpb,amv.tmcylvgLpdibbi�tlu-,t P, Msy>.00aad4leMTrv.¢o
Job-
Truss
Truss Type
Ory
Ply
A0280563
WRMSCM1560B1L
B03
Common
2
1
Job Reference (optional)r
A-1 Roof Trusses, Fort Pierce, FL 34946, design@attruss.com
Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Thu
4x4 =
6a
3x4 = 5x8 = 4x4 =
Dead Load Dell. =1/8 in
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(too)
I/deft
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.37
Vert(LL)
-0.14
7-13
>999
360
MT20
2441190
TCDL 10.0
Lumber DOL
1.25
BC 0.72
Vert(CT)
-0.27
7-13
>848
240
BCLL 0.0
Rep Stress Ina
YES
WB 0.19
Horz(CT)
0.03
6
rda
n/a
BCDL 7.0
Code FBC2017/i-PI2014
Matrix -MS
Weight: 84 lb
FT =10°/
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 5-1-3 oc
pudins.
BOTCHORD
Rigid ceiling directly applied or 7-4-3 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed dudng truss erection, in
accordance with Stabilizer Installation uide.
REACTIONS. (lb/size)
6 =
699/0-3-6 (min. 0-1-8)
2 =
789/0-7-10 (min. 0-1-8)
Max Horz
2 =
100(LC 12)
Max Uplift
6 =
-180(LC 13)
2 =
-219(LC 12)
Max Grav
6 =
699(LC 1)
2 =
789(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
TOPCHORD
2-3=-1175/797, 3-4=-866/597,
4-5=-863/595, 5-6=1159,782
BOT CHORD
2-7=-631/1022, 6-7>610/983
WEBS
4T286/491, 5-7=328/363,
3-7=-364/386
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult--160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpl=0.18; MWFRS (envelope)
and C-C Extedor(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
4) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding ISO lb uplift at
joint 6 and 219 lb uplift at joint 2.
LOAD CASE(S)
Standard.
am+.+oywi,.a.-r.�ao�ttarsses rsa,lar,, raxw rsxaes.,acm+oncws ctisroveal� �ccm,ow�o�e-r+ra ve^yms�w.+u.w�.a mnt,moap. n..:w �ramwan
swm.ey Fjgn�rrmn. nwbmrnu u.wea.i..s..mw ce mo:mry n¢w w.�m,nwwwo. groobOs a�i^ea�+wbg6+tavzuryenc^On)meW o,.^troo mn..M..� aannaounha PEczeas m.bvemYm Pm., �m.m^b��^ipW^=.'Y Ja�wde...s. T-..bRM mou�y!+mel�f,1•M omgneu�..-�mm,mwp..maabn..-. .ymYu�N.Mn Tmu,mnpBu�^d M�aRnatl4>• wwa Pmu Fnomormnus, s,s
qnn-y,. pny. ypN®EnyeAmT.BJbg.We%m/. WmvW mOn RgHIB �NppiWp WemW lP11.41e MP✓�mmWlW ukmrybtlwmWTfm:+y�9�WL!q:�u4./^W^'�T�r++ay..^�b M,epv�64Y/: NS, S}IruSa ehtl.
dA CM�.aWfmlr--"'fi CrtatlM AOTW v?MRaeda.mJ pvbtlnnmM611rv)(L vwJatlNymla.ffian IB6WW SMiMTNs�.SBCPmenAnrulA anG RRau.R].48
ir�+'®9m>n�. 'aPK41F,e. W myaNLirtf _
m,i:ays,.mn=nbi.a€w+Lr e9�ee r,mu.nb=mm,We,mms.aa.eM�4aw.ua�«?,gmasonBmrhrw�}n.h�l�a:wWeroN�awr m,e�nsv P.9�Ei/>T+a sM��cnwrm�{wc^_tiw oae mareo,e
<aN xpin�.v p�ly.yfwW v.'NLf.CWPgNO]p180.\qmtTrcw-pµWu�ppngpgy,minp,®gylm,gnpM�pb]vAwf YmrvMmip,m' a1M PMTwvm
Job
Truss
Truss Type
Oty
Ply
A0280564
WRMSCM1560BIL
B04G
Half Hip Girder
1
1
Job Reference(opfiona0
A-1 Roof Trusses, Fort Pierce, FL 34946, design@attruss.com
3.
Run: 8210 s May 18 2018 Print: 8.210 s May 18 2018 MITek Industries, Inc. Thu Aug 22 13:41:17 2019
3x4= 1=4 n 44=
LOADING(psf)
SPACING-
2-M
CSI.
DEFIL
in
(loc)
Well
Lid
TCLL
20.0
Plate Grip DOL
1.25
TC
0.71
Vert(LL)
0.09
6-9
>999
360
TCDL
10.0
Lumber DOL
1.25
BC
0.58
Vert(CT)
-0.13
6-9
>999
240
BCLL
0.0 '
Rep Stress Incr
NO
WI3
0.76
Horz(CT)
0.02
5
We
n/a
BCDL
7.0
Code FBC2017/TP12014
Matnz-MS
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2z4 SP No.2
WEBS 2z4 SP No.3
BRACING -
TOP CHORD
Stmctural wood sheathing directly applied or4-1-0 oc
pudins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 9-2-9 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation oulde.
REACTIONS. (lb/size)
2 =
802/0-7-10 (min. 0-1-8)
5 =
1059/0-3-6 (min. 0-1-8)
Max Horz
2 =
166(LC 8)
Max Uplift
2 =
-264(LC 8)
5 =
-384(LC 5)
Max Gmv
2 =
802(LC 1)
5 =
1059(LC 1)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (fib) or less except
when shown.
TOPCHORD
2-3=-11571360, 4-5=-294/188
BOT CHORD
2-6=-377/959, 6-12=377/980,
12-13=377/980, 5-13=-377/980
WEBS
3-0=-8/626, 3-5=-11701453
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
-2}Wind: ASCE-7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load noncencurrent with any other live
loads.
5)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-" wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 264 lb uplift at
joint 2 and 384 lb uplift at joint 5.
7) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 260
lb down and 270 lb up at 7.0-0, and 118lb down and
129 lb up at 9-0-12, and 120 lb down and 129 lb up at
10-10-12 on top chord, and 338 lb down and 72 lb up
at 7-0-0, and 77 Ib down at 9-0-12, and 78 lb down at
10-10-12 on bottom chord. The design/selection of
such connection device(s) is the responsibility of
others.
8) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Veit: 1-3=60, 3-4=-60, 5-7=-14
Concentrated Loads (Ib)
Vert: 6=338(F) 3=-213(F) 10=118(F) 11=120(F)
12=-56(F)13=-57(F)
Dead Load Defl.=1/161n
PLATES GRIP
MT20 244/190
Weight: 57 lb FT=10%
Job-
Truss
Truss Type
Qty
Ply
A0280565
WRMSCM1560B1L
805
Half Hip
1
1
Job Reference o ticnal
A-1 Roof Trusses, Fort Pierce, FL 34946, design@1altnlss.cem Run: 8.21u s May 18 2U16 Print: 8 21U s May 18 2018 MTek Industries, Inc. Thu Aug 22 13:41:18 2019 Page 1
ID: Id_OOXyyT61Bi_TXoljwHHzefvK-5C183tbzgQCV 03hidVK7hAvl XQM9CDa0OQFXlyll77
-1-4-0 9-0-0 11-11-12
1-0-0 9-0-0 2-11-12
5x8 z 1.5x4 II
4x4 = 1.5x4 II 4x4 =
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
Udell
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.54
Vert(LL)
0.25
6-9
>566
360
TCDL 10.0
Lumber DOL
1.25
BC 0.82
Vert(CT)
-0.33
6-9
>425
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.30
Hom(CT)
0.01
2
n/a
n/a
BCDL 7.0
Code FBC2017/rPI2014
Matdx-MS
LUMBER -
TOP CHORD 2x4 SP M 30 •Except•
T2: 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 6-0-0 oc
puriins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 7-5-2 oc bracing.
MTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (Ib/size)
2 =
52710-7-10 (min. 0-1-8)
5 =
433/0-3-6 (min. 0-1-8)
Max Horz
2 =
207(LC 12)
Max Uplift
2 =
-137(LC 12)
5 =
-137(LC 12)
Max Grev
2 =
527(LC 1)
5 =
433(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
TOPCHORD
2-3=-4341146
BOT CHORD
2-6=-267/290, 5-6=-269/296
WEBS
34=49/323, 3-5=-572/520
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Extedor(2) zone; cantilever left and right
'exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
pending.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 137 lb uplift at
joint 2 and 137 lb uplift at joint 5.
LOAD CASE(S)
Standard
Dead Load Der. = 3116 In
PLATES GRIP
MT20 2441190
Weight: 601b FT=10%
Job
Truss
Truss Type
Oty
Ply
A0280566
=.so
WRMSCM156OBlL
B06
Monopik:h
2
r
A-1 I1001 I russes, Yon merce, FL 34946, design(m_altmss.com Run: 8.210 s May 18 2018 Print 8.210 s May 18 2018 MiTek Industries, Inc. Thu Aug 22 13:41:18 2019 Page 1
ID:ld_OOXyyT61 BI_T)Co1)wHHzefvK-5C183tbzgQCVi03hIdVK7hAWLXX09AMa0OQFX1y1177
-1-4-06-3-14 11-11-12
1-4-0 6-3-14 5-7-14 -
1.5x4 II
4
3x4 = 1.5x4 11 44 =
LOADING(psf)
SPACING-
2-M
CSI.
DEFL.
in
(too)
I/deft
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC
0.46
Vert(LL)
0.06
6-9
>999
360
MT20
244/190
TCDL 10.0
Lumber DOL
1.25
BC
0.33
Vert(CT)
-0.07
6-9
>999
240
BCLL 0.0 '
Rep Stress her
YES
WB
0.42
Horz(CT)
0.01
5
n/a
n/a
BCDL 7.0
Code FBC2017/rP12014
Matrix -MS
Weight: 62lb
FT=10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 6-0-0 oc
puriins, except end verticals.
BOTCHORD
Rigid ceiling directly applied or 8-1-5 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
527/0-7-10 (min. 0-1-8)
5 =
433/0-3-6 (min. 0-1-8)
Max Horz
2 =
264(LC 12)
Max Uplift
2 =
-117(LC 12)
5 =
-200(LC 12)
Max Grav
2 =
527(LC 1)
5 =
433(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOPCHORD
2-3=-605/196
BOTCHORD
2-6=-481/483, 5-6=-481/483
WEBS
3-5=-549/547
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpl=0.18; MWFRS (envelope)
--and C-GExterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-M wide will fit between the
bottom chord and any other members.
4) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 117lb uplift at
joint 2 and 200 lb uplift at joint 5.
LOAD CASE(S)
Standard
Job•
Truss
Truss Type
Oty
Pty
WRMSGM1560BlL
CJ1
Comer Jack
10
1
�0567
Jab Reference o tional
A-1 Roof Trusses, Fort Plerce, FL 34946. design@al Wss.com
Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. l
I'
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
floc)
Weft
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC
0.18
Vert(LL)
0.00
7
>999
360
MT20 2441190
TCDL 10.0
Lumber DOL
1.25
BC
0.03
Vert(CT)
0.00
7
>999
240
BCLL 0.0
Rep Stress Ina
YES
WB
0.00
Horz(CT)
0.00
4
n/a
n/a
BCDL 7.0
Code FBC2017TFP12014
Matrix -MP
Weight: 6 lb FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 0-11-11 oc
purins.
BOT CHORD
Rigid ceiling directly applied or 10-M oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
-5/Mechanical
2 =
181/0-7-10 (min. 0-1-8)
4 =
-21/Mechanical
Max Horz
2 =
42(LC 12)
Max Uplift
3 =
-5(LC 1)
2 =
-71(LC 12)
4 =
-21(LC 1)
Max Grav
3 =
12(LC 8)
2 =
181(LC 1)
4 =
20(LC 8)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 fib) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vul1=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp 8; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
'rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 5 lb uplift at
joint 3, 71 It, uplift atjoint 2 and 21 lb uplift atjoint 4.
LOAD CASE(S)
Standard
Pu.,.a®=awi,�.. m.-wJ cros. mycscsC 'lr,Exuut Ttias...ecaminouscJisr4urn(guYE uvnrom�cu +m„vmti�+my m3a.mm,.m mmnv�o+w Q a•'m+vhm)=2 6mi'%€rvnmmM1n^W ns�Mr<?�wUMauer�a�M pn N4 Y•ttm mnievu xY4wbtm 0+TWHN N�iiuq FabT F'9^a^`5V+:6i�YE^Imml. P»uelmeMTUOnVeu^n en: Ja,e�BMI+G PE6i&H
�E6mMe�Yntlm�mmvOmWmmt`h bmynNtiv WwTrvm J,ryYJmmYLO iN-LlM4mbnm.nJlvq bS.q cmCtcn.wZWlYetlumNMrrvm M/ry9wNrymW mp vti'P/dE+ WrYXwyEipinBUlnp G.t 91814
�DeCmrav�NJia¢?aJetlmM9: nTdsi^��P.ew¢+b9.tl4e R40a!•C �YYYSBm1e�MlPl.4..4pe'�tlN1NIW mrlmY.futlwdWTt� �'9��^�•M:tl>R.�uMPz mlyv9MN1w^4�I: NS1 SLutie PM.
Dsa9wmW GnbYrN Nwnsstl m4mMTW W'NPm'%�YeNR'J�.c+MErt BUYmSLmnimr'J£mtM'Mmmmr,14SU0W 'MTRM59Wme mYn,WlmpwNEWw: 4lelwn Wnvtad�tti;w•O RPm,u. R 319Y8 OHcBptnp '1R
PNW"MTaT �9M+,Ei NP+gnw MTNd4mMaEmm.�mW�uPaY+YaeMwiM�LmLveymM�mMNwWNNaA Cm4�YNvdrad iM bOm'�MegoiV mMOiW 9u15n00rs5+vmTrvd6Wtl,�vemY,OfMm✓��piN� Ose M2VM18
iYJIM.mt Y.mmi.M(nvJMTK1:G9)*¢'SDROf 844gxlTl�ev a-ReprWxmmmeivmYwnpt Nary Ymn,3 Wei WlwTrfOw �IeMpm+nvzui+MAl PeN.Twvs `
Job
Truss
Truss Type
Qty
Ply1.
A0280568
WRMSCM156OBlL
CJ3
Comer Jack
7
1
Job Reference (optional)
n nwi uusso, ruu nee , r� .T9n9o, ues�ynl,a muss.wm mun: o.uu s inay io
0M
16
I J:91:'J N.V
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
1/defl
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.18
Vert(LL)
-0.00
4-7
>999
360
MT20
244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.08
Vert(CT)
-0.01
4-7
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz CT)
-0.00
3
n/a
n/a
BCDL 7.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 12 lb
FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-11-11 oc
puriins.
BOT CHORD
Rigid ceiling directly applied or 10-M oc bracing.
MTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 = 64/Mechanical
2 = 21210-7-10 (min. 0-1-8)
4 = 23/Mechanical
Max Horz
2 =
82(LC 12)
Max Uplift
3 =
-43(LC 12)
2 =
-63(LC 12)
Max Grav
3 =
64(LC 1)
2 =
212(LC 1)
4 =
43(LC 3)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcument with any other live loads.
3}'—This trusshasbeen designed for alive .load of _
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-M wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 43 lb uplift at
joint 3 and 63 lb uplift at joint 2.
LOAD CASE(S)
Standard
Qaav eim9MY�W[.w•M>SDG"iRI188Es r'6Fklfpj,Efl,ERAt tewJsaaewotr�bxscvsraecn (9v+esleen[orn s+wrJmavmryar[�..9.awM mawem�m ro T— omPoa+tme{�Y+°em
6� Afmh,uia eloralmM MYaaMl�MdmPwyDD:mMA'PH wea]u 4WaevIbMTW bav[Ib Hvirvn(kaTE/-0fi[mfiYpS'MmeHE�ie�}EY9uI m vnTtUO,mvula-eA Jmtl B6Nl9GPE 8iB09
�. mw[a.••�m.�.�eamRm.Jaoaea.,�orn. ®rurw[>r�++am.e.mo° .�.,..+.ma m.aw�d ��. �^om.a�s.,m.marmarawr,ma e•w,..m+�Haa.: wmeHme
pmm.p�psvappuCgvmmMBudfp.Mfin.,.mN[mtJdU. W4NeNC. baltiYbi:mseulT%T. 45w1d1N1W.N RYaa>amp+TPaC vN�M9 tmbs9�.Nv4.YemYS.wp[IleipT[W bM ��AG9161!
m��9��u.��o[[i+m.wray.w ao.xismomwmeTw.awsmun[[s.wco'a�mmanbwaraaomnarw[n���mm[em+%scow�+�w+mTRm.esacA....a�..mv mam+*ur: JJst aiw aw.
�gxu',(DIORT D�6va+db eaM^MaTMY.Mirth.�a+M+fiaexweMeGa�w.lgr[N.wmm++9NbntlomoabM.k TMi6mW[mitmkroTMBw �r�wbw: t%eelnmm�m[omeelv+!eu RPfe+a.ftJ[9[6
[aM[L �14�v PYSM[Mm'NH.CayvgtlOi418at PstTTvcsi[-11vo,matim Nt+ua�neni,M1mmyiwm,fimd�fiWrttmm Uw wimv Mms[v[aal PmtSi'vew �de[mefmTxa 6Y4v!PEgmNOI^^THorSMi r� UTs: �3LNt8
Job-
Truss
Truss Type
Oty
Pty
A0280569
WRMSCM1560BlL
CJ30
Comer Jack
1
1
Joh Reference o tlonal
A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MITek Industries, Inc. Thu Aug 2213:41:20 2019 Page 1
ID:Id_0OXyyT61Bi TXo1jwHHzefvK-2a9vUZdEMlSDxKD4g2XoC6FMKLH1dATsTivMbByll6z
2-7-7
277
314 =
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc)
I/deft
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC
0.11
Verl(LL) -0.00
3-6
>999
360
TCDL
10.0
Lumber DOL
1.25
BC
0.10
Vert(CT) -0.00
3-6
>999
240
BCLL
0.0 '
Rep Stress Incr
YES
WB
0.00 -
Horz(CT). -0.00
2
We
n/a
BCDL
7.0
Code FBC2017/TPI2014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 2-7-7 oc
pudins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 =
95/0-3-6 (min. 0-1-8)
2 =
67/Mechanical
3 =
27/Mechanical
Max Horz
1 =
52(LC 12)
Max Uplift
1 =
-13(LC 12)
2 =
-47(LC 12)
3 =
-1(LC 12)
Max Grav
1 =
95(LC 1)
2 =
67(LC 1)
3 =
41(LC 3)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl.. GCpi=0.18; MWFRS (envelope)
-arid(--CExterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) - This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
'bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 13 lb uplift at
joint 1, 47 lb uplift at joint 2 and 1 Ib uplift at joint 3.
LOAD CASE(S)
Standard
PLATES GRIP
MT20 2441190
Weight: 8lb FT=10%
Job
Truss
Truss Type
Qty
Ply
A0280570
WRMSCM1560BlL
CJ3L
Comer Jack
2
1
Job Reference (optional)
A-1 Roof Trusses, Fort Pierce, FL 34946. design@alvuss.com Run: 8.210 s May 18 2018 Print 8.210 s May 18 2018 MiTek Industries, Inc. Thu Aug 22 13:41:21 2019 Page 1
ID:Id 0OXyyT61Bi_TXoljwHHzefvK-WnjHhves7La4ZUoGNm211KoWvldl MdjOiMew7dyll6y
-id-0 2-71-11
1-0-0 2-11-11 -
LOADING(psf)
SPACING-
2-M
CSI.
DEFL.
in
(too)
I/deg
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.18
Vert(LL)
0.01
4-7
>999
360
TCDL 10.0
Lumber DOL
1.25
BC 0.12
Vert(CT)
-0.01
4-7
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 7.0
Code FBC2017/TPI2014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 2-11-11 oc
puriins.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installaton guide.
REACTIONS. (lb/size)
3 =
64/Mechanical
2 =
212/0-7-10 (min. 0-1-8)
4 =
23/Mechanical
Max Horz
2 =
82(LC 12)
Max Uplift
3 =
-43(LC 12)
2 =
-74(LC 8)
4 =
-29(LC 9)
Max Grav
3 =
64(LC 1)
2 =
212(LC 1)
4 =
43(LC 3)
FORCES. (lb)
Max. Comp./Max. Ten. -All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Extedor(2) zone; cantilever left and right
exposed ; porch left exposed;C-C for members and
forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2}This truss has-been designed fora 10.0-last bottom_
chord live load nonconcument with any other live loads.
3) "This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-M wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 43 lb uplift at
joint 3, 74 lb uplift at joint 2 and 29 lb uplift at joint 4.
LOAD CASE(S)
Standard
PLATES GRIP
MT20 244/190
Weight: 12 lb FT=10%
Job`
Truss
Truss Type
city
A0280571
=JbRf,,,n,
WRMSCM1560B1L
CJS
Comer Jack
6
onall
n-� nw� � msddq rvn r�erue, r� .r,drv, ucaiynLd uw>.wm
214 =
d lndy 10m Io r61IL. v.e m s inay la zula m I ex Inoustnes, Inc. I nu Aug 22 13:41:21 2019
411-11
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc)
Well
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC
0.37
Vert(LL) 0.04
4-7
>999
360
MT20
2441190
TCDL 10.0
Lumber DOL
1.25
BC
0.29
Vert(CT) -0.05
4-7
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB
0.00
Horz(CT) -0.00
3
We
n/a
BCDL 7.0
Code FBC2017frP12014
Matrix -MP
Weight: 18 lb
FT=10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING-
TOPCHORD
Structural wood sheathing directly applied or4-11-11 oc
pudins.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
122/Mechanical
2 =
278/0-7-10 (min. 0-1-8)
4 =
48/Mechanical
Max Hom
2 =
123(LC 12)
Max Uplift
3 =
-81(LC 12)
2 =
-73(LC 12)
Max Grav
3 =
122(LC 1)
2 =
278(LC 1)
4 =
77(LC 3)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left ex`pcsed;CGC for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) `This truss has been designed fora live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
'4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 81 Ito uplift at
joint 3 and 73 lb uplift at joint 2.
LOAD CASE(S)
Standard
QCnm�'Pd�KM'mnrEv-1NR JF RiIaSFE CEELIFRI_. GENEML lE0.VSWC@Jo1fCx6G4tflYE0.j6WER)PCrt,tl'MEYYEIP-.bm Ye.n/mdtpva�rcy,sytl,uEnmo a,MTxn OesT 1)n�(IW)ioYW
Wlme�u.IT4eWnh�Ya'tlp,MNO.u=ttl'PV
E.�MERInTre6n�o eYW tm^sT>O�M eui q.sOb FTWbbYBhV. N�Tem P%G^Gl^^�bgi.a6PWMEN�). CnrtlmvY![IO�RAM=P,:
arrbeerinGTdN+^tln`9�Yb �C+��%bMti,ynMO� Tns bY�mYc�OO?A'u,bifFY.Th�Y^+i^��m4daiW cmfhne ua+ll%WmJLLa lmbn,lBtl1^in Onm,muA'XVYAe.
JaWBMiW PEOtNB
VMh XmBEnG���✓W LA9161!
0.ew W0 4�a,].xW lmvME�AWT�^Pw AOnmdNdY,�R40e i6GWdWtiN�lmtlTPlt TIi41mdo11NRlOMI,nYMt..s�d0u'IF^A�rr�69»E!�B. ✓a✓f.mYO�Waw1b��Mtlbtls
LL51 SI lutls&W.
Bim�p CnppmiEfinmrID�Nrvmade[nes Ttlaw 4a v.�.m+aal,.atl.=•dxa.u+a rPnP�tUery>MnFrn \7�M Wu,M TrivN �A'aen�ertwafv
N+i�NMT'w Cn9^r.6iMTV End�mNThA4nGwarta�inemurp�0,4naG3{C¢M:f � MbWdvu: WchMabe,f_maD�R+iwG
+�d^tl44oM �h.4!u Tl�6pwvg FigivaTAF M,Edfq O�rynFeirvveYtl @grYNpfsR}idS.Q <➢...
RP'wu.R9lWB
eID9: DSRYAI9
[aWa4MYmpoMeMnTPL6Gxpa�.tOip16K1Pa1Tn¢v�-��
AmNzm�deu6lon�+tm`vgbet"APdWH�mrtOn wNw lwmb�MNK1 PMTwd�.-
Job
Truss
Truss Type
Oty
Ply
•r
A0280572
WRMSCM1560BIL
CJSA
Comer Jack
1
1
e
Job Reference (optional)
A-1 Roof Trusses, Fort Pierce, FL 34946, design@aluuss.com Run: 8.210 s May 182018 Print: 8.210 s May 182018 MTek Industries, Inc. Thu Aug 22 13:41:22 2019 Pagel
ID:Id_0OXyyT61 BI_TXoljwHHzefvK-_zHfuFR)ufxBeNTxTZGIXKgw8xJ54z9x0OTf3y116)
1A-0 4-2-0
1-0-0 4-2-0
2x4 =
4-2-0
LOADING(psf)
SPACING-
2-M
CSI.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.23
Vert(L-)
0.02
4-7
>999
360
MT20 244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.18
Vert(CT)
-0.02
4-7
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 7.0
Code FBC2017lTPI2014
Matrix -MP
Weight: 16lb FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 4-2-0 oc
puriins.
BOTCHORD
Rigid ceiling directly applied or 10-M oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
99/Mechanical
2 =
250/0-7-10 (min. 0-1-8)
4 =
39/Mechanical
Max Ho¢
2 =
106(LC 12)
Max Uplift
3 =
-66(LC 12)
2 =
-68(LC 12)
Max Grav
3 =
99(LC 1)
2 =
250(LC 1)
4 =
63(LC 3)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces 8 MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
_3)-lDhis buss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-" wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 66 lb uplift at
joint 3 and 68 lb uplift atjoint 2.
LOAD CASE(S)
Standard
w 9mcwAM.,1n.au.mf aoGrnws¢[¢r¢T11ar)GEHTTw.*eans.ae8udnaHs cusrouEx{euvrmscmaiiEer+.lExremvrf«MM�w o�n^^1�.awnomm. m'.Tro+auv�de+.vR6�).=daw
B ��A'EN�^t'�^n�4eM'eurnwunmmni.a.( a, a.Nh. wstsmF.ttppnn��ccWW u.eTm c+*aomaveuq aux7mv�F^GMnkV{.esgwyeraB*°i. CnvYmer{tW mn+BMem Jueleowim eE¢zem
' c¢Woe♦tlAGMe.bmYang£mbBnWVNgbBZdagn✓tlee+h lwe Yptla[m"BgTW N4LTmtlsa:°a^J6ma 6n®^YrmCAm. wOaNymW,®mbm T},.vNotll3^.HrWSCunayme+l JtlO� WTi4Ha,u6WneeNp W91615
.a.,reeones+wo=.aa�lmmeaul*aa+a^^6nv.muaus.wceaiee.bwtiNereme..va ln.}.w4^'aver.Tw.w®)rau.eu.rr.�GAaieBH�4n�Y.�ew¢a,.a>+m.6axbe.re�[wnr us19w1 Ea4
eBMGAfInpCep.LeV CnY,MP Hm¢SL WIMTs IO�WBSPv(4vmQGmCMxe M➢a 0.13,5 imal8tlmypisnffir, eP.4LppuebMBY TFl,M AMNMrv.N 1u.W^erq BelVwe. 1Ht4Nwal60 rtyvsTAba_e�6 Rhr4ft3,¢M
yuu.eMmoixa[�mgmr. ec�Ty fires+-cMTrynus 4o=.r.mM1eio}rstre+r0.tna yie Omen m+a.wo�Lie,Whr•4aW++N.s;)iMBt�rEreiFaNOTMBeMvq 4aipwmYmp 6l++m Ew�ewrom4d6 A:'M oaia'B¢RYmtB
�eodYmJ4miCntldlM n'IM1B.�y�1QPOfBA1MatTryws-flpprW¢lpnpppsivrpYM VYIu�,.ApMpbBMypBm�llyipmnn,m N0.lPytTusa'
Job-
Truss
Truss Type
Oty
Ply
A0280573
WRMSCM15BOBIL
CJSC
Comer Jack
1
1
Job Reference (optional)
A-1 Roof Trusses, Fort Pierce, FL 34946, design@aiVuss.com
Run: 8.210 s May 18 2018 Print: 8210 s May 18 2018 MiTek IndusWes, Inc. Thu Aug22 13:41:22 2019 Page 1
ID:Id_OOXyyT61Bi_TXoliwHHzefvK-_zHfuFBJurixBeNTxTZGIXKeW 8uw54z9x00Tf3y116x
4.7-7
4-7-7
3x4 =
4-7-7
4-7-7
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc)
I/deft
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.38
Vert(LL) 0.04
3-6
>999
360
MT20
244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.33
Vert(CT) -0.04
3-6
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT) -0.01
2
n/a
n/a
BCDL 7.0
Code FBC2017rrP12014
Matrix -MP
Weight: 15 lb
FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 4-7-7 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-M oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 =
16910-3-6 (min. 0-1-8)
2 =
121/Mechanical
3 =
48/Mechanical
Max Horz
1 =
93(LC 12)
Max Uplift
1 =
-27(LC 12)
2 =
-83(1-C 12)
Max Gmv
1 =
169(LC 1)
2 =
121(LC 1)
3 =
74(1-C 3)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10: Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for -members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcument with any other live loads.
3) `This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 27 lb uplift at
joint 1 and 83 lb uplift at joint 2.
LOAD CASE(S)
Standard
Job
Truss
Truss Typa
Oty
Ply
A0280574
WRMSCM1560BlL
CJ51-
Comer Jack
2
1
Jab Reference (optional)
A-1 Root Trusses, Fort Pierce, FL 34946, design@albuss.com Run:8.210 s May 182018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Thu Aug 2213:41:23 2019
I
3.4 =
411-11
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.49
Vert(LL)
0.10
4-7
>563
360
MT20
2441190
TCDL 10.0
Lumber DOL
1.25.
BC 0.44
Vert(CT)
0.09
4-7
>648
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
3
We
n/a
BCDL 7.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 18 lb
FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING-
TOPCHORD
Structural wood sheathing directly applied or4-11-11 oc
pudins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
122/Mechanical
2 =
278/0-7-10 (min. 0-1-8)
4 =
48/Mechanical
Max Hom
2 =
123(LC 12)
Max Uplift
3 =
-81(LC 12)
2 =
-102(LC 9)
4 =
-51(LC 9)
Max Grav
3 =
122(LC 1)
2 =
278(LC 1)
4 =
77(LC 3)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed; porch left
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2}71ris truss has been designed for a 10.0_pat bottom_ _
chord live load nonconcurrent with any other live loads.
3) . This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 81 lb uplift at
joint 3, 102 lb uplift at joint 2 and 51 lb uplift at joint 4.
LOAD CASE(S)
Standard
Job'
Truss
Truss Type
Oty
Ply
A0280575
WRMSCM1560BlL
CJ6
Comer Jack
1
i
Job Reference (oollonall
A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 182018 Print: 8.210 s May 18 2018 MTek Industries, Inc. Thu Aug 2213:41:232019 Pagel
ID:ld_0OXyyT6IBi_TXo liwHHzefvKS9rl6bf6fyg000yfVA4VgltnlYD5gXCJ9g70B Wyll6w
-1d-0 1
6-8-0
14-0 5-8-0 '
I
2x4 =
LOADING(psf)
SPACING-
2-M
CSI.
DEFL, in
floc)
Well
L/d
TCLL
20.0
Plate Grip DOL
1.25
TC 0.51
Vert(LL) 0.07
4-7
>897
360
TCDL
10.0
Lumber DOL
1.25
BC 0.40
Vert(CT) -0.08
4-7
>803
240
BCLL
0.0
Rep Stress lncr
YES
WB 0.00
Honz(CT) -0.00
3
n/a
We
BCDL
7.0
Code FBC2017/TPI2014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-8-0 oc
purlins.
BOTCHORD
Rigid ceiling directly applied or 10-M oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
141/Mechanical
2 =
302/0-7-10 (min. 0-1-8)
4 =
56/Mechanical
Max Horz
2 =
137(LC 12)
Max Uplift
3 =
-94(LC 12)
2 =
-77(LC 12)
Max Grav
3 =
141(LC 1)
2 =
302(LC 1)
4 =
89(LC 3)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult-160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exter or(2) zone; cantilever left and right —
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 94 lb uplift at
joint 3 and 771b uplift at joint 2.
LOAD CASE(S)
Standard
PLATES GRIP
MT20 2441190
Weight: 20 lb FT = 10%
WM'mY.N-R.IRPA TNR6FSrEELL61')GEHFN.L TERN6�l4Va61nOxSG`JSIOYEP�WFP-�AC4iW.EDGMENi'Tmm..Ye.SI�+PP^+.^v1^.NWnoYam Q.6 Trva MST D•.+�^ORD% M
QM�ewo'
P �' �YE+SwvMnvo.Iwl4rmSw Mmausrw.s'aaen MTOD.ubATm meta NTmfaY um11n N'rtANbxLw N.bsCbP�FM�m: g0aaw+.*I EnP'®).PSeWm v/lOD nwsm4sm
.tu�ae60nptd.nlnWPo^�h9�RRs'�Nb NOng.,✓OnxS'�Trvs>I�! iW W��, TR.1.lMd �Qi^.@I®.i°•®^YiWAu•aSbM1).edvw JlMinupevir @+MN SSN P1bb WYw
w..... u. }.auvw•ew•m,meB.vwp.Ceshw.a,u+mwadumAConm4baeY+mPD mt.wiv!♦.:bvaw. Nmo -v
LM BD.IJePPE 63&r9
Wmb HWYrTB'reeaIME191P15
vauwau.'flux:+�cl.mimo.•�.onname.annawvp e. N.,.mavre:ery
A Nmh35N:uANee iDD Wflw pwpa5wapmCMgalroh 15gE�.wPs�?J?.1i1/P��w'✓+��=O.PomNp IyTRSW EGA rtSOMppmNguOTrR Te 2bMga Nertymre l#fwE
usI SLwYeeM.
RP'wm f131M6
�mnp(bproaMCmFacmt
MG la,T�Dngmr. 6peaeb P+9MpSm9irvnNwo6rtwt.tielmqu[,xya 6M1neC tylEg4a¢yeeC.ymr•Ponp ElryipvL•ainNl M6CesTY E,9e¢v TM,B¢Nsq M,WFnirvm SplRn Ey�,Mmp f➢
- �"�
Dee. 6MYtD19
'e.y..r..twm�en®b4WHTW1.'GgIryYD]Df6hIRxeT,uea-Reps,yeemgprtpx,mRibmvlmm�inppl.pNCMgNM mairym3egal Ye ggRT�sez`
Job
Truss
Truss Type
Oty
Ply
A0280576
WRMSCM1560BlL
GE01
Monopltch Supported Gable
1
1
T
Job Reference o Oonal
A-1 Roof Trusses, Fort Pierce, FL 34946. design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MTek Industries, Inc. Thu Aug 2213:41:24 2019 Page 1
ID:xhtbvZpZyEOpo7r87gW18cymLmn MPOJxgkOGyfOyXr3ubkNy02oyf4Z SSOKtakyyll6v
DX4 9
1.5x3 II
LOADING(psf)
SPACING-
2-M
CSI.
DEFL,
in (too)
I/de0
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.08
Vart(LL)
Na -
n/a
999
TCDL 10.0
Lumber DOL
1.25
BC 0.03
Vert(CT)
n1a -
n/a
999
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT)
0.00
rue
n/a
BCDL 7.0
Code FBC2017/TPI2014
Matrix-P
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3 -
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 2-8-0 cc
pudins, except end verticals.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 cc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erectlon, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 =
71/2-8-0 (min. 0-1-8)
3 =
71/2-8-0 (min. 0-1-8)
Max Horz
1 =
39(LC 12)
Max Uplift
1 =
-13(LC 12)
3 =
-33(LC 12)
Max Grav
1 =
71(LC 1)
3 =
71(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. -All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the
truss only. For studs exposed to wind (normal to the
face), see Standard Industry Gable End Details as
applicable,. or consult qualified building designer as per
ANSUTPI 1.
3) Gable requires continuous bottom chord bearing.
4) Gable studs spaced at 2-0-0 cc.
5) This truss has been designed for a 10.0 psf bottom
chord live load nonconcument with any other live loads.
6)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-M wide will fit between the
bottom chord and any other members.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 13lb uplift at
joint 1 and 33 lb uplift at joint 3.
LOAD CASE(S)
Standard
PLATES GRIP
MT20 2441190
Weight: 9lb FT=10%
CSEUEzycra:Ear`i.E(ws.acmuvmoxswsrwEAcauvanurommtxm-fo..n..axrdamwa.r..d,..a ®„e.T D.+vm..aw rrom,mm.
Q,ya.vw?uF+...P.-+-,AmussES
t Ea�lyErys.�,Ore,wJa[tb4n w.UnY»aN,n�rebalcrt.BalDO.aNr Atawmv,eArdtlotlW buW M,lFr IlAPbrYd Nri,u5a R9yv E,qer�(re.SryT/.Ergew,)iMw/m�q'TW,rpasnM1e,n
Ju,:IBDIPIq PE6t11Ptl
rae!.sin QMTin✓sx�q'n+�e9nwwRWrbPwtlr,vP.NP+��]bT,magWlwceTW aM.uWIh1.TroNpnmr:pA��,b�]rgmn:.tlmvew•vin9Nm�QAt Tony F/ylypbM�mpanaiAV Mvn
WTd�fbum FrymmEp LA i,B15
A`-nCWOmelanOviW Sr^foNHW�YVPN+�.nM1avb162w.G4W,9C.lvIpJYkR[a4atl 1PN.Mr.T�dbTpD etlwYYlw WbTum.sfubnYlymnO.YwM.Y.1Wle+W W9�NY4'0.afp^rM4J
arledNn9ta?Jraatl WSSN NaOeriM 110DMNFSSa+}Y.4+�Y,nY,lyN,b-0CwMomT?CrM1ebmny. RbY-01�'�bh Rletl Si9U.sMsasabl MWP�a. TRAMwMwtwWNr,M
45(SI,O61G.
ftPlfm.FL3
mb+da,.T,,,.. �,BwME�9++��arl,m YwM'..�,a�.s.,mac.eN�m,M.a..e�Pv.b.�+wh.ow�Aww.ly EwvbEv.�nF�re.%+S,v D•.w�p.iw.gmwe�v�mw.r?w3^a. ?^
Dm: .10fB
'<W'Y.iIDmme3s�m MMtlhThf.GN>nYi.02MOMI RONTrvc%s-Pcrofpmdp„paui,bµampyrvaatl�RpC,wwNll+edmiymnv,m Q0.fAwl i�cn.
Job-
Truss
Truss Type
Qty
Ply
A0280577
WRMSCM1560BlL
HJ7
Diagonal Hip Girder
3
t
Job Reference (optional)
A-1 Roof Trusses, Fort Pierce, FL 34946. design@altruss.com
Run: 8.210 s May 18 2018 Print 8.210 s May 18 2018 MiTek Industries, Inc. Thu Aug 22
3x4 = 1.5x4 11 3A =-
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Gdp DOL
1.25
TCDL
10.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
NO
BCDL
7.0
Code FBC2017/TPI2014
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
4 =
159/1vechanical
2 =
442/0-10-6 (min. 0-1-8)
5 =
274/Mechanical
Max Horz
2 =
182(LC 4)
Max Uplift
4 =
-107(LC 4)
2 =
-180(LC 4)
5 =
-64(LC 8)
Max Grav
4 =
159(LC 1)
2 =
442(LC 1)
5 =
274(LC 1)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOPCHORD
2-11=-734/174,11-12=-684/191,
3-12=-683/181
BOTCHORD
2-14=266/679, 14-15=-266/679,
7-15=266/679, 7-16=266/679,
6-16=-266/679
WEBS
3-6=-717/281
CSI.
DEFL.
in
floc)
I/deft
Ud
TC 0.59
Vert(-L)
-0.05
6-7
>999
360
BC 0.53
Vert(CT)
-0.10
6-7
>999
240
WB 0.40
Horz(CT)
0.01
5
n/a
n/a
Matrix -MS
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed; end vertical left
exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load noncohcurrent with any other live
loads.
3)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 107 lb uplift at
joint 4, 180 lb uplift at joint 2 and 64 lb uplift at joint 5.
6) Hanger(s) or other connection devices) shall be
provided sufficient to support concentrated load(s) 77
lb down and 90 lb up at 14-9, 77 lb down and 90 lb
up at 1-4-9, 36 lb dawn and 41 lb up at 4-2-8, 36 lb
down and 41 lb up at 4-2-8, and 66 lb down and 88 lb
up at 7-0-7, and 66 lb down and 88 lb up at 7-0-7 on
top chord, and 12 lb down and 40 lb up at 1-4-9, 12 lb
down and 40 lb up at 1-4-9, 16 lb down at 4-2-8, 16 lb
down at 4-2-8, and 30 lb down at 7-0-7, and 30 lb
down at 7-0-7 on bottom chord. The design/selection
of such connection device(s) is the responsibility of
others.
7) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=60, 5-8=-14
Concentrated Loads (lb)
Vert 11=57(F=29, B=29) 13=-74(F=-37, 13=37)
14=46(F=23, B=23)15=9(F=4, B=4) 16=56(F=-28
, B=28)
PLATES GRIP
MT20 2441190
Weight: 43 lb FT=10%
'1..1 RDS1W166E5('6ELLH1't6ENEAK IFAN6MfAtdRWS W51(WEN 1T>bY6��66tl`M I' lWeYppmywmnd mC Trva OuiP �M^6RWlvdM
Qmbv^�9aY
! �61 ERxwwwbmms •n,abke•u• uemm.me.r m.m.mo.m46'aro.onmo.awe•%+.4a�mewtror®.. ,w a 1,w oenm mm+e�m n.r6 Y a^am).. m.sw m, ^rroo,mw.em,.
.wnnemriwv[smm
am�nuaAnpvea.bnaui}*anM,mim^✓W bo-aLayndW..gMT,uap'csgm Wlpp .uvin Tf0.}TxatlrSnaunplmgb3n9oa�wn,umaNarmtl,�+a i css myauLfry ®p. try W,w
pRV•vylm,aEpeelmlMBWYybaq.w.pWmm6a MgG,W1SQbN W6q WgvtlTPJ�' tlNWI6Omb/%�mdWTliw,.n6aFpMM.ryllvy9F�W'm�b'mn9me0bMrtymWry!'.
'Mn4Houca E+9YievYp G9t6�5
451 S, Wee6M16
2+4It49peajmNEmilnW f➢KKeaselaR TOD.MHPtm^laci6mYMwaAnP.,Mn✓LGSimYNl6vhNPIwmA'nyQ3M plO45M]Cl'TRad L9CAmeRMenMAbnlMtl9Y�^R iGHL6M•WmMr+b�nYA
FL Rwm.R31M6
tluYlaleTNa0.c9v. 6fwmRY 29.<m VMTN44wMt'bm.+mWe W,mMti c94wd blbGmAeclM•>ARn i„w!^PMIiVN.4rldMT,n EfW^MCninowb W,rM6o1YN0a9r'aiNAh+d?E..vw•,avgfiW?✓9.RL
ON: 065LM19
copW�zJ ys6fm]nTRf'GquVAl0 Yuf6 1Pa1Twv.-RCWtlaM,aMbvewknOylmm.npduC.Y3NMCWalmipne cu,tlM Fw<Tw�`
Job
Truss
Truss Type
Ory
Pry
A0280578
WRMSCM156081L
HJ7A
Diagonal Hip Girder
1
1
Job Reference (optiona0
A-1 Roof Trusses, Fort Pierce, FL 34946, design@altmss.com
Run: 8.210 s May 18 2018 Print 8.210 s May 18 2018 MTek Industries, Inc. Thu Aug 22 13:41:25 2019
ID:Id_OOXyyT61Bi_TXo1)wHHzefvK-OYyoXHhMAa4W 2562eb7zvAy4gMscl LBbd=7
-7-4 9-10-1
3x4 = 1.0. 11 3X4 =
LOADING(psf)
SPACING-
2-M
CSI.
DEFL.
in
(loc)
Vdefi
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.63
Vert(LL)
-0.05
6-7
>999
360
MT20 2441190
TCDL 10.0
Lumber DOL
1.25
Be 0.59
Vert(CT)
-0.11
6-7
>999
240
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.42
Horz(CT)
0.01
5
We
n/a
BCDL 7.0
Code FBC2017[rP12014
Matrix -MS
Weight: 43 lb FT=10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 6-0-0 oc
pudlns.
BOT CHORD
Rigid ceiling directly applied or 10-M oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
4 =
180/Mechanical
2 =
453/0-10-7 (min. 0-1-8)
5 =
301/Mechanical
Max Horz
2 =
182(LC 4)
Max Uplift
4 =
-125(LC 4)
2 =
-185(LC 4)
5 =
-67(LC 9)
Max Grav
4 =
180(LC 1)
2 =
453(LC 1)
5 =
301(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-11=-777/214, 11-12=-727/231,
3-12=-726/221
BOT CHORD
2-16=-2881720, 16-17=-288r720,
7-17=-2881720, 7-18=288f720,
18-19=288f720, 19-20=288f720,
6-20=288/720
WEBS
—3=6=Z601304
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. 11; Exp B; Encl.,'GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 pat bottom
chord live load nonconcument with any other live
loads.
3)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a.
rectangle 3-6-0 tall by 24)-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 125 lb uplift at
joint 4, 1851b uplift at joint 2 and 67 lb uplift at joint 5.
6) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 77
lb down and 90 lb up at 14-9. 77 lb down and 90 to
up at 14-9, 36 lb down and 41 lb up at 4-2-8, 36 Ito
down and 41 Ib up at 4-2-8, 54 lb down and 69 lb up
at 5-10-11. and 66 lb down and 88 lb up at 7-0-7, and
76 lb down and 103 lb up at 8-0-2 on top chord, and
12 It, down and 40 lb up at 1-4-9, 12 lb down and 40
lb up at 1-4-9, 16lb down at 4-2-8, 16lb down at
4-2-8, 24lb down at 5-1G-11, and 30 lb down at 7-0-7
, and 40 lb down at 8-0-2 on bottom chord. The
design/selection of such connection device(s) is the
responsibility of others.
7) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (pit)
Vert: 14=60, 5-8=-14
Concentrated Loads -(lb) _
Vert 11=57(F=29, 8=29) 13=14(F)14=37(B)
15=56(F)16=46(F=23, B=23) 17=9(F=-4, B=-4)
18=19(F)19=-28(B) 20=-36(F)
Y ,.a�Mn,.,1..n..z, ao6P.w[sara ryrir[rt.i�Pu tu+wm,acawvrloPstirsrann[re��aclvmh�oraeam�nvna� a�mn..a ren,mv,a�.rw rr.m��*am�^a �^.
Q cw=�xercmw,eu.,®[nq.famm.w u�w.w�.v.«m n,q con. 1wF. c�y.Wia..a r>m.moear.na aaY«..o..+w�m�an.�sw[1•me,a�l.waaon.ntmo .n; .tense owl�PEezma
e a.w✓bw�iq M.Lry'pa10[wbrw.a 5.a.coo/nlnmlwfAU.aK.��A®.1aLw[aalm.�rvaay.a,aatr�rrv[�Ta /on�re�m.+[wma. wmbxoux 6wneelwub, s,5
awa�ruaaT qz rv4.c. �rnv MT uN m,.,✓u^.aaaa♦Cmway,.a w�eA+�p.wewmo.wm.raa.e.am.4w.`man,wa.a:: whw.vn..eti.m,a...uamroaveurr V.: sn,m. w�..a' wn,oaaw�[mew 9v,[*9 �v nm. maeeemww4w bdeiGo mmmamlapar6eWa,u. Tttrbinnma,mmtLfe.,4 werwae�e..uosm��m«rs[nn�,,.wires:owa��l+n erm.wseU.:x.A.m'y>s.� ra nt�.avwe
wCpbrWp.b+Mtl.W TN6po,lly6p'mMgNOTM B,Ab�p 0[[p�a0Trva6y,Ye,,Fsprw,p(mppe`S_✓q IJI 098A°2YEM
OIB.[iWdu(avm46MbhlNl.�Cy}ryYJCA16ATPmlTx[a[-AMc,4sDm GTf N[w�[;®aRfmt wPclubbO,APaEP.e.rtien"P�eMNh1 PaRTm[6.'
Jobe
Truss
Truss Type
Qty
Ply
A0280579
WRMSCM1560BIL
HJ7L
Diagonal Hip Girder
1
1
Job Reference o tlonal
A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com
Run: 8.210 s May 18 2m a Print 8.210 s May 152018 MiTek Industries, Inc. Thu Aug 22 13:41:26 2019 Pagel
L
214 = 1.5x4 II 3x4 ='
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.59
Vert(L-)
0.11
6-7
>999
360
MT20 2441190
TCDL 10.0
Lumber DOL
1.25
BC 0.53
Vert(CT)
-0.10
6-7
>999
240
BCLL 0.0
Rep Stress Incr
NO
WB 0.40
Horz(CT)
0.01
5
n/a
. n/a
BCDL 7.0
Code FBC2017/rP12014
Matrix -MS
Weight: 43 lb FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
pudins.
BOTCHORD
Rigid ceiling directly applied or 7-6.4 oc bracing.
MTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
4 =
159/Mechanical
2 =
442/0-10-6 (min. 0-1-8)
5 =
274/Mechanical
Max Horz
2 =
182(LC 4)
Max Uplift
4 =
-110(LC 4)
2 =
-271(LC 4)
5 =
-229(LC 5)
Max Grav
4 =
159(LC 1)
2 =
442(LC 1)
5 =
274(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - Al forces 250 (lb) or less except
when shown.
TOPCHORD
2-11=-734/451, 11-12=-684/468,
_ _3-12_=683/462
BOTCHORD
2-14=-523/679, 14-15=-523/679,
7-15=-523/679, 7-16=-523/679,
6-16=523/679
WEBS
3-6=-717/553
NOTES-
1) Wind: ASCE 7-10; Vult-160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. It; Exie B; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; porch left exposed; Lumber DOL=1.60 plate
grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
3) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 110 Ib uplift at
joint 4, 271 It) uplift at joint 2 and 229 lb uplift at joint 5.
6) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 77
lb down and 90 It, up at 1-4-9, 77 lb down and 90 Ib
up at 1-4-9, 36lb down and 41 lb up at 4-2-8, 36 Ib
down and 41 lb up at 4-2-8, and 66 lb down and 88 lb
up at 7-0-7, and 66 lb down and 88 lb up at 7-0-7 on
top chord, and 51 lb down and 40 lb up at 14-9, 51 Ib
down and 40 Ib up at 1-4-9, 10 Ib down and 40 lb up
at 4-2-8, 10 lb down and 40 lb up at 4-2-8, and 29 lb
down and 71 lb up at 7-0-7, and 29 lb down and 71 lb
up at 7-0-7 on bottom chord. The design/selection of
such connection device(s) is the responsibility of
others.
7) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=60, 5-8=-14
Concentrated Loads (lb)
Vert: 11=57(F=29, B=29) l3=-74(F=-37, 8=-37)
14=46(F=23, B=23) 15=-9(F=-4, B=-4) 16=-56(F=-28
, B=28)
Qgm.*wmcMi �. •&, nooFTX499Ears=ti[aY�B*iEwy lEHM9`m%40tA,f1015 eJsiouear�vFiyccxlaW,m� Nf`� v Nd3w pw�kn zaC ,m Oemgn vreraq sdda.
r 4`OaMEy,+m dwlle�+w MWdMka«Ynmwm4 �FMe wemaa c"++%muR MPaiOa aYrvv m?WFW^�wtl^p 0asaevaYEnF+N roruvr ioU��
J»iBMJw PE 99t03
�i+u MfisP�+eetlm9M1�Mc�i�%�.Yfb BeyypdLLYYMYTw'vpep]mmaYCD q,}�mEalp-i bs;emu,rp bxC cmNmn YSaN:YN�mNb (wM8u0GT9 ��P+50'tlRe-
iti Oneis Wl�nL4'i%a�§.ma Aat4+9 a+9�'w 3,M m1bIR4..0ai6C.IvetiW.f-66<uk i�MT^'e1dMTL0adYWMN 6gs1}im:n`v46^3X�M.!Y9
N1We XWYEWNeeaIMG91615
eMTPlt Ne6a:¢,m6b�=!gLmOVMrt,W�N01gY::
o! M3e�6u�aP Re$CiMCede[aF Pr9aYesef lMiFIO WNeAerdie:fatl{mtla'^e9ftlw8.il6T3 �T.='se Wxy 6MdTPIf.Neram,TBSG�pyev�d�Q'ieaMercNA!i'-^�!�8'^d>t✓s'-"IPFYMXM We 2yvaAe. fend
MS151 Luee BIW
FPIwe.R9e9K
MN'u[iaTnmihOfM(.€Y�YE�49 TN4HwMa}un,.aun�eertasRWndbi[Lw+bva+i�Wrn n+R,elMM�PWe1��TFe FCwM4 ETnidw tt9Tdro Ev33vn[+aX'Katimx 6YAc'�wMUF'e'MdS^4k
Wu: O9Trzdt9
ogi3cNbnusm. *q¢rp,MnVH Wppp.15 GTQf6At1+N[Srvwc-ij'ep,W-vypcyppyivr�riasylm,q npMYXef MPw[tlq MWilmevmpMM PMTwm
Job
Truss
Truss Type
Qty
ply
+
A0280580
WRMSCM1560BIL
J7
Jack -Open
9
1
r
Job Reference (optional)
A-i rcwT i cusses, ron Tierce, rL u4 b, oeslgnLwalvuss.com Rum d.ziu s May 18 z018 rnnc a.zlu s May to 2u1a MIreK mdusmes, Inc. I nu Aug ee 1sal:zr zu1
3x4 =
7-0-0
s
Dead Load Dell. =118In
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL
in
(loc)
Vdefl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.86
Vert(LL)
0.17
4-7
>478
360
MT20 244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.64
Vert(CT)
-0.20
4-7
>413
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.01
3
We
We
BCDL 7.0
Code FBC2017/rP12014
Matrix -MP
Weight: 24 to FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 2-2-0 oc
pudins.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
178I10echanical
2 =
34910-7-10 (min. 0-1-8)
4 =
70/Mechaniral
Max Hom
2 =
164(LC 12)
Max Uplift
3 =
-118(LC 12)
2 =
-85(LC 12)
Max Grav
3 =
178(LC 1)
2 =
349(LC 1)
4 =
111(LC 3)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcument with any other live loads.
3) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss wnnections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 118 lb uplift at
joint 3 and 85 lb uplift at joint 2.
LOAD.CASE(S).
Standard
Job,
Truss
Truss Type
Gty
Ply
A0280581
WRMSCM1560BlL
J7L
Jack -Open
5
1
Job Reference (optional)
A-1 Roof Trusses, Fort Pierce, FL 34946. design@altiuss.cem Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Thu Aug 22 13:41:27 2019 Page 1
ID:Id_OOXyyT6IBi_TXo1jwHHzefvK-Lx4YyyidiBKEHPFOk09R?b2R49ZgmJG W HSEKHylI6s
-13-0 3-0-0 7-0-0
4x4 = 3x4 =
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.52
Vert(LL)
0.18
6-9
>460
360
TCDL 10.0
Lumber DOL
1.25
BC 0.54
Vert(CT)
0.15
6-9
>542
240
BCLL 0.0
Rep Stress Ina
YES
WB 0.19
Haz(CT)
-0.00
6
n/a
n/a
BCDL 7.0
Code FBC20171TP12014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 6-0-0 oc
pudins.
BOTCHORD
Rigid ceiling directly applied or 6-1-2 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
4 =
91/Mechanical
2 =
34910-7-10 (min. 0-1-8)
6 =
159/Mechanical
Max Horz
2 =
164(LC 12)
Max Uplift
4 =
-69(LC 12)
2 =
-134(LC 9)
6 =
-125(LC 9)
Max Grav
4 =
91(LC 1)
2 =
349(LC 1)
6 =
165(LC 3)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
TOPCHORD
2-3=-323/338
BOTCHORD
2-0= 582/283
WEBS
3-6=-307/633
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; porch left exposed;C-C for members and
forces 8 MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
3) a This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 691b uplift at
joint 4, 134 lb uplift at joint 2 and 1251b uplift aljoint 6.
LOAD CASE(S)
Standard
PLATES GRIP
MT20 2441190
Weight: 30 lb FT=10%
ryaa. MmaMY rvvh 4, ROJF.Tq�55Ed r6E1y£q`i, GENFIVLlFlM5MLN0Y(4xSp/STPIES'reN'E.ACY.IiO'M-EWY3�1'.su VMluepiq.pmel.nntl mCneGimbslrvv[L=`8^.V.uuiYnOD)'��`.
ft✓�R/EM^amreM1 M NeYenw A`ermsweN'n lop. miTa�W^'n'*MaL.mw ee.mNty MTODbb aFe,.N.Tuq Da.Sa.^Bba^�pY 44NM+heni�N.w+cp m,a^YIOD ieT�+an..
Jarim BDwW+PE62B09
•,v�Maanlµ.peb,.trnYugiivpmpsL'fybOe`GayndAaaagalrum bp'c43mt[alWwwryry. mW,iF-1.l4apv�n, m�ur��rtay W2nq tw,ugy{p/eJ,m.gp,. Tnw bray &Atnge OaaapmOpNM.
D•W�^ Pawaed OS WG.(N,B6bNlWNV'vle lPoM®fietl,waruaTwe:�^9I.MM:�mq+.
WT'e M0u5e FMbeeX,g C191615
�Ya0aaJa tul,e+¢NpNmLw9uMNM mdtp�.t.L,iµpwtivlW ^+�w 4n W1✓-i9aMbNreaW.v?M';
HA Da pmraMCmea�4. R➢We?'xtlW TOD VGib CaWvmp GmaNntlle bMr'cR.iu'AWM'eRm'raFn RSCPCmbnweYTRNtSC�sartNnw'lmTenermgurJ�e: hfi WrtgvaMda uN
a:,ur Dmro�.F+mex ero=+a-waTxruwn,meraa... mmmw ®rower. eow.e.e <.waararo ttmwe.....a..eT�sa.�.. arch®.wTaamr+.e Tm.er�o �vw..oe.tie�wd. cn
N519Lue 8htl.
a
o...�m
..mLYawbmi.p®MlneCmTP4Y Cgp.rpN010164 Pvf imva-RaprNi[Lm,tlO®.Cmu,vll. vrrmm,3 pM'eM1Cwbarff�wepAemm mo.M pe#Tvg'-
13
om=asatme
iii,`
Job
Truss
Truss Type
QtY
Ply
+
A0280582
WRMSCM156OBlL
J7T
Jack -Open
6
1
r
Job Reference (optional)
.. , nw, ,iuo en nc � ornrv, aesynl-e mu5s.mm
3
3.4 =
RUn; 0.41U 5 May l82UlO Vnnl: 0.2lU S May lU ZUlb MI IeK
LbM It
4
IOC. ❑u AUq zz 10:41:z0 zul s
li
Dead Load Deft. = 1/8 in
LOADING(pst)
TOLL 20.0
TCDL 10.0
BCLL 0.0 '
BCDL 7.0
SPACING- 2-M
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TP12014
CSI.
TC 0.34
BC 0.34
WB 0.00
Matrix -MR
DEFL_ in floc) Ildefl
Vert(LL) 0.22 6 >384
Vert(CT) -0.23 6 >359
Horz(CT) 0.07 5 n/a
L/d
360
240
n/a
PLATES GRIP
MT20 2441190
Weight: 27 lb FT = 10%
LUMBER.
TOP CHORD 2x4 SP M 30
BOA CHORD 2x4 SP 2400E 2.0E
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 105 lb uplift at
TOP CHORD
joint 4, 78 lb uplift at joint 2 and 7 Ib uplift at joint 5.
Structural wood sheathing directly applied or 6-0-0 oc
BO T C
ROT CHORD
LOAD CASES).
Rigid ceiling directly applied or 6-0-0 oc bracing.
Standard
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
4 = 166/Mechanical
2 = 360/0-7-10 (min. 0-1-8)
5 = 87/Mechanical
Max Hoe
2 = 164(LC 12)
Max Uplift
4 =-105(LC 12)
2 = -78(LC 12)
5 = -7(LC 12)
Max Gmv
4 = 166(LC 1)
2 = 360(LC 1)
5 = 118(LC 3)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult-160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; SCOL=4.2psf, h=15ft;
Cat. 11; Exp, B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord -live load nonconcurrent-with any otheriivetoads.
-- - - -
3)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
Job'
Truss
Truss Type
Oty
Ply
A0280583
WRMSCM1560B1L
T06
Common
4
1
Job Reference (optional)
A-1 Roof Trusses, Fort Pierce, FL 34946, design@aluuss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MITek
08 =
6.00 12
1.5x4 II 0x8 = 1.Sx4 II
US =
1-24 8-0-0
LOADING(psf)
SPACING-
2-M
CSI.
DEFL.
in
(loc)
I/defl
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.24
Vert(LL)
0.09
9-10
>915
360
TCDL 10.0
Lumber DOL
1.25
BC 0.38
Vert(CT)
0.07
9-10
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.09
Horz(CT)
0.00
9
We
n/a
BCDL 7.0
Code FBC2017ITP12014
Matrix -MS
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 6-0-0 oc
pudins, except end verticals.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MITek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
10 =
415/0-3-8 (min. 0-1-8)
9 =
41510-3-8 (min. 0-1-8)
Max Horz
10 =
147(LC 11)
Max Uplift
10 =
-194(LC 8)
9 =
-129(LC 13)
Max Grav
10 =
415(LC 1)
9 =
415(LC 1)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOPCHORD
3-4=-95/251, 4-5=-95/251
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult-160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat II; Exp B; Encl.. GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left and right exposed; parch left
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom
chard live load noncencurrent with any other live loads.
4)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-M wide will fit between the
bottom chord and any other members.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 194 lb uplift at
joint 10 and 129 lb uplift at joint 9.
LOAD CASE(S)
Standard
1�7
Inc. Thu Aun 2213:41:29 2019
PLATES GRIP
MT20 2441190
Weight: 69 lb FT=10
Qqry epru9WYR+b+a•A,RPYTRI$6E6�SEllCq'ALfl1Eli(L1[FYLyb CyORgYyGJLiOYERj911VEiCJAC,ttiWM1EDW�i1•Amn Np/farp. pm� NmE qi Tq Trvv Oerpi PveMp(10d)aeEM
SpyMFRrylnwrMmu l�ti MmuaV Wsmee a�nY{n Pal90.a^f)P''am w�^+PodPu+�Y4aeum1b2+TYPb4vYm NeYaun�4^F/VMab'PM144 aS1EniYM)Rvutlwn'l TO0 i4:?emaa: JamIBO✓JeGPE@B09 �
my,maW W{vdmabJammm,X9^b AhvyndUaaryYTv bpIMmINYOpw�iy.Wvlilf.iMA �®wip4evaba6igamf�Me uftld[s�dvnq Y+iNubq&#a.g Bs.,ryv's34ydTa. lNn'e1buH FIgMo1ry CA9t8t5.
pnm.papanyamMamCym,mNBu q.Lw,q�r (n YPr 4N,6GteflJtip �md1p1.4.1N gaueldWlW mq#V,udMir�m:+ALLgluMcg.Mq mY[va wtl b+aV il'Ybue,u9vsb,ny YSt9tutle BFd,
W ➢i Bu�np9mObstl lsMWa Hwa'x,mY iUEM9ulvatWaamf 6�a�ad4 P� fEde90JanmmA�FL9 WM�L+1M'IP,mW 96LPdi,aMrtrctlbG�^^�®9Wa,n. NS<t11meNGrtalve�ea?mE RRe,�a.R91Bb
Wlvl#AaThmC^W"aI.9PmIb ENam�WTry0a4wMa[0vat'.wYaYOPWaaIaOmE Hb C[nLMapeaGu�Ma,4^iNaB WdainM'.w4TrBLW�uMEFm.!.m'v WTM &itlMq O!vARmTnY Hsm 6W9�, of YM1L+Y RA OTe OYlY1%8
{yXLvl Wnao6hmMmlMi.'LWp.gftCRp19a, RwTrveg�-RamWabsdoeamvrs�y lnsltam,b>M�tiYGaePwYPa MM1npne su, W /N FMTmz�.
Job
Truss
as Type
pry
ply
A0280584
WRMSCM1560B1L
T06A
Common
1
1
,
Job Reference fpti.n.11
A-1 Root Trusses, Fort Fierce, FL 34 b, deslgntdalvuss.cam Run: 8.210 s May 182018 Print 8.210 s May 18 2018 MTek Industries, Inc. Thu Aug 2213:41:29 2019 Page 1
ID:Id 0OXyyT61Bl_TXoliwHHzetvK-HJCJMektEoaxXjPprRBv407tmzH?EEHBYbaLP9y]16q
1-2-4 44i0 7-9-12
1-2< ~ !t1_2 33.12 1-2-4
6.00 12
4x,
48 =
I;-
1.5x4 II 3x3 = 1.5x4 II
3x8 =
1.24 9-00
M1-0b 7-9.12
11 67-8
LOADING (psi)
SPACING-
2-0-0
CST.
DEFL.
in
(loc)
Udefl
Ud
PLATES GRIP,
TCLL 20.0
Plate Grip DOL
1.25
TC 0.19
Vert(LL)
0.09
7-8
>900
360
MT20 244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.37
Vert(CT)
0.07
7-8
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.09
HOrz(CT)
-0.00
7
n/a
n/a
BCDL 7.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 65 lb FT= 10%
LUMBER -
TOP CHORD 2x4 SP Nc.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 6-0-0 oc
puriins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation uide.
REACTIONS. (lb/size)
8 =
322/0-3-8 (min. 0-1-8)
7 =
322/0-3-8 (min. 0-1-8)
Max Horz
8 =
135(LC 11)
Max Uplift
8 =
-98(LC 9)
7 =
-155(LC 9)
Max Grav
8 =
322(LC 1)
7 =
322(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
TOPCHORD
2-3=-129/283, 3-4=-129/283
WEBS
2-8=-208/305, 4-7=-208/304
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult-160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Ezp B; Encl., GCpi=0.18; MWFRS (envelope)
--and.C-C Exterior(2) zone; cantilever left and right
exposed.; end vertical left and right exposed; porch right
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate gdp
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrenl with any other live loads.
4)' This truss has been designed for a live load of
20.Opsf on the bottom chard in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members. .
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 98lb uplift at
joint 8 and 155 lb uplift at joint 7.
LOAD CASE(S)
Standard
Truss
TrussType
OtyPlySCM1560BIL
L*WOP"M
T06SGE
Common Structural Gable
1
1Job
Reference o 5ona)
A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com
Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MTek
48 =
6.Oo
3.8 = 3x6 =
1-24 940
18 Fi 7812 J-11-a
1aa sra a11�
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
In
(loc)
Well
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.24
Vert(LL)
0.09
9-10
>915
360
TCDL 10.0
Lumber DOL
1.25
BC 0.38
Vert(CT)
0.07
9-10
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.09
Hoa(CT)
0.00
9
n/a
n/a
BCDL 7.0
Code FBC2017ITP12014
Matrix -MS
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins, except end verticals.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
10 =
41510-3-8 (min. 0-1-8)
9 =
415/0-3-8 (min. 0-1-8)
Max Horz
10 =
147(LC 11)
Max Uplift
10 =
-194(LC 8)
9 =
-129(LC 13)
Max Grav
10 =
415(LC 1)
9 =
415(LC 1)
FORCES. (lb)
Max. Comp.IMax. Ten. - All forces 250 (lb) or less except
when shown.
TOPCHORD
3-4=-951251, 4-5=-95/251
NOTES-
1) Unbalanced roof live loads have_been considered for
- this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left and right exposed; porch left
exposed;C-C for members and forces 8 MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the
truss only. For studs exposed to wind (normal to the
face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as
per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise
indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 pat bottom
chord live load nonconcument with any other live
loads.
7)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
8) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 194 lb uplift at
joint 10 and 129 lb uplift at joint 9.
LOAD CASE(S)
Standard
Inc. Thu Aua 22
PLATES GRIP
MT20 2441190
Weight: 84 lb FT=10%
w.. •4�ROJF TflUS6E61'bhlER`j GBMENy TEamb.eawmM1rnbWslouEn ��g{1YFFf�CFCaam.ECC+4l+r+mF vti r�-9�w4^°Bn.amm,ummdsT,m Bea,;r.Bn+ne Oortimaw
Qge®MwcA'i
Mm Nmixa
t 6T=^fi✓EMlna, bmv tlwb Nbmw Mm4e e,mtl tM ND. rub A'PN wm wi+L✓�s NYpeMbNi�JbP O®i^EM�mi Bi4'mWbEnGA^), On MtlmaMTOO %Rvbm
JYMIBPnlPPE6t�
esWr'vMWcMm OR*��in9.ssµnW4NbMbiaq,.tlYnmN'm Tnre�paWwnaY4la�..uwe Jp f.rmEnk^�TVtl�a�+m cue,tla,e �uJY+!latlwgW auefvey&,B1T9sa�-®d�r�0'mm�.
ButlN p,fpm,T mamN6tlWR4@a i64 RfW JV,m20UmgM'bld dATlum:*m�91rNM.r�tlY Watln NNrt+8
v.TWeXase En4PwrIM C/.916f6
MS1 Snub &A,
Cev tl.e P.✓ maY,avCl9eYvn Nmle atllFl }1N45a'd a1,NbMmptialAY�
M➢eBWHmGGnM+�W CaT•Wa, NmmiM w4 r1B�'aN4u pv.M6wW P�b+Mestl Me&id]mBCwnpaq^!SJeiY Mm yem IBSCOMWYSihT%aWSBCAwrtAiereMhv.WKNY�.Ysu tGyrhf Lb mFtlm��T9. wa.
M4�.B�T`�^y°'°^B TNUMynlamme.Wear egmW�4MNq�Loa�eq,wf,pmmmamybiLp�MoeS iM&s,MYbcMrwNOT [q Baliq irvn bymv5pngrtivry9u�9: <A
FY HUU. FL.L91fi
OAB: BYMOIB
grWid9wTrvm Oevym
aTWiet,m.n�wa41mc1miM}'CwjggC'dI6A1 Fc[1Trvv�_gpmy„�yy,tl[®trgrtgKA mytrmLEpGxONl Wn,lA5mm�pnmv 'n,NM RsY.T,ussc'
Job
Truss
Truss Type
Dry
Ply
.-
A0280586
WRMSCM1560BIL
VM08
Valley
1
1
,
Joh Reference (opllonall
H-i Moan cusses, ron rierce, ru 94e4b, cesign(oaT uuss.com
4
0
Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MTek Industries, Inc. Thu Aug 2213:41:30 2019 Page 1
3x4 =
2
3x4
3
4
2x4 i 1.Sx4 II
LOADING(psf)
SPACING-
2-0-0
CSL
DEFL. in (loc)
I/deft
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.54
Vert(LL) n/a -
We
999
TCDL 10.0
Lumber DOL
1.25
BC 0.22
Vert(CT) n/a -
We
999
BCLL 0.0 '
Rep Stress Incr
YES
WB "0.00
Horz(CT) -0.00 4
nla
n/a
BCDL 7.0
Code FBC2017/TPI2014
Matrix-R
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 6-0-0 oc
pudins, except end verticals.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MITek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 = 19315-11-8 (min.0-1-8)
4 = 19315-11-8 (min. 0-1-8)
Max Horz
1 = 70(LC 12)
Max Uplift
1 = -46(LC 12)
4 = -58(LC 9)
Max Grsv
1 = 193(LC 1)
4 = 193(LC 1)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and dght
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate gdp DOL=1.60
3) Provide adequate drainage to prevent water ponding.-
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 pat bottom
chord live load nonconcurrent with any other live loads.
6)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 46 lb uplift at
joint 1 and 58 lb uplift at joint 4.
LOAD CASE(S)
Standard
PLATES GRIP
MT20 244/190
Weight: 20 lb FT=10%
RMF.TPIISY64'8P=LER%.GEIQ4LL.TFAY' mbGMTtlfICISCUBiMERR:�TERIFOOlO,Y1EDGMEN�-Iran. tY.A'M.9^ Mmm!� M M rvvwmTb Twv P�M 6!+'a+6 n0%W M
QFYvebuu`OMY,wmmb'Rl
0
S'^bER^�,.�min W[IbMaa M�aa Mma�.a'NIm MTDD�MY Km.mitv.4i4b4L'NUW bMTm bM-A:4.l�un Ono EM�mq rie:Eieb ER�d.Muitnli® r>�m.^ym
Jm19MWGPE 6IDW
�xm�mabmems..'.+wm�..i a�+a:rm. a.a.i+an,.w*T„�.aa�ww.a.Tooran.mmTm:xr.a.w...mvaa�awe'u•d�..+ran+r.awdwT,..,>a..romewem.nvm���+vdP.
wm.,a:o...r.ma..aenma..omeatia o.•�ustia.o+ewaa.,ec.a.mc,am,m nwma.:�e rrcv.T'. mno�+.awroa.mmnw.,.snr.e..:rs,m.ar� a..�*.v..�:wa...ar..mvwoaem�dw
wwanw. e+m...as uaier.
usswaei+e.
VwBu6lrvGswwatl CmmN Meb.apmamMttiOsewwmsusmtlW:+.dem8r,�w<mr{vmCda9mMr�IB64W�NhTRmC69Gm.nrmwmmamm.lAt]n,s-mlmMhmRm,KK'M1..M
RP4�w.R3a918
GIMNBmTrvR2Mry'M,6.veNY£.gMud.T�MmuR9e�. ✓.b. tl.1sw J+=W $Yia'Pml N�.MEP ^mdryh!•r 1s�.a'+m'b ilm8yc+gyE,p',wrm NOi tti Budygp.jy,motvp8rynnEry,mmdspm?.tip.N
qp: �ylp10
eyetl-vf'wmiAmaWmY,Thl LplegyOR�6M, pvfineve-Remm�madAvm�vrwy.NWI+�M1gffi+ISnlmlWe6mmm®pmmm,aA. Ga9nma.
Jotf
Truss
Truss Type
Qty
Ply
A0280587
WRMSCM1560BlL
VM10
Valley
1
1
Job Reference (optional)
A-1 Roof Trusses, Fort Pierce, FL 34946, design@attruss.00m Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 Mi Industries, Inc- Thu Aug 22 13:41:312019 Page 1
ID:ld_OOXyyT61Bi TXoliwHHzefvK-OiK3nKl7mQgfmOZBmEN9RCCin1Vi8FU?v3RU2y116o
8-0-0
8-0-0
2x4G 5
1.5x4 II
1.5x4 II
1.5x4 II
LOADING (psi)
SPACING-
2-M
CSI.
DEFL.
in (loc)
Well
Ltd
TCLL 20.0
Plate Grip DOL
1.25
TC 0.23
Vert(LL)
n/a -
n/a
999
TCDL 10.0
Lumber DOL
1.25
BC 0.11
Vert(CT)
n/a -
n/a
999
BCLL 0.0
Rep Stress Incr
YES
WB 0.12
Horz(CT)
0.00
n/a
n/a
BCDL 7.0
Code FBC2017/TPI2014
Matrix-P
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
puffins, except end verticals.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 =
89/7-11-8 (min. 0-1-8)
4 =
11117-11-8 (min. 0-1-8)
5 =
33517-11-8 (min. 0-1-8)
Max Hom
1 =
147(LC 12)
Max Uplift
4 =
-51(LC 12)
5 =
-155(LC 12)
Max Grav
1 =
89(LC 1)
4 =
111(LC 1)
5 =
335(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 fib) or less except
when shown.
TOPCHORD
1-2=-2751117
WEBS
2-5=-272/418
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcument with any other live loads.
4)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 51 lb uplift at
joint 4 and 155 lb uplift at joint 5.
LOAD CASE(S)
Standard
PLATES GRIP
MT20 244/190
Weight: 31 lb FT=10%
Qabnnva�9.Nmbbu-hraoff musst9 tsELLemf. cEne+w.Tuws.mcanvmoxsa9fotiaY�w�nsarYamtnca+Evrbn..v.M�M wY.�.•w,..a.ewa. e,. T.. p.woi+..w tivolwe..
S+-v YE�Yrrlarcin WtlYwnw..Untrvc4ervv�Uh:m1�TOD.uY/A\'wmxR.bn G4hY ✓MbunlbhTilO bK6 Y�l,wpat Eno^ee'qB.a.SA+NErpisd.MMm+�I]ilOnpa.e'^fin .LYMIBUWy�PE 996
acrJnuCArMJnvonuwY'sb9w+ae^'VaYM6n Ln^q*NlbnAibTundn[bftnMlCO Y WVRy. T.a �ow.WmnbvfTi[ 44nf.n tiM1VbtlwdPw irvnbrMAGInCbM.mRmNIJMM WIM' IbYA EMwarIN CR91B15
Onv. Yb 0.mInnNMlvlbMn[v6.81'96b®nSn,O�mhYtlM4'L.NO^.ILb�Il'tr�OmYtb1PN.TNSFo�'Yd4s1D0 bllw IXYOinsn 99n^m^J. 9n.F✓gAy, iat ✓e[MnMl0.W�F>YbM/ at51511,6@
'aae`lutlq Onna^mma Gmv+n>-nnmYs+aban6s TCGwevwcm,n�e9�^4Mu>w&JiN�^V+^i'�L?nwv u�Nivtlm(65G9p�*Y^9N TPIba49CAon�ww^enlTm+'0ixY[eb�v��vamr:wwa �,e ftfiem.FL9Y919
a(oiMYb Trv,a O^'i'rC& ^aY£ryv�bd Trvp LLnbaLw.wbe r9�wnn Ga!nNM�G+i c1NrtMK��n!rL9�TMP�w.tiMlTM6P�IIEN^w��NTeY9'.1ytl.Wq^',wSwbhbm Erye�na!Jn^Y�'^E RO DBb: 09YYA1B
�mY4YYmm4waa6ticGbi?N. @pYrvJJ 03S16A Y Pv}Trvaeea-Rb-.wAvmd MOaPmanLtlbylrsm.bpofMaIMUYTeo+R�n pemcaMdFl RDaf 9ww
Job
Truss
Truss Type
Qty
Ply
r
A0280588
WRMSCM1560BIL
VM12
Valley
1
1
FJobference
(optional)
A-1 Kow I russes, tort Pierce, FL 34946, design(rnaltross.com Run: 8.210 s May 182018 Print 8.210 s May 182018 MlTek Industries, Inc. Thu Aug 2213:41;31 2019 Pagel
ID:ld_OOXyyT61 Bi_TXoljwH HzefvK-DiK3nK17mQgfmOZBzsEN9RCBJnOZi77U7v3RU2yllSo
2x4 i' 5
1.Sx4 II
1.5x4 II
3
4
1.5x4 11
LOADING(psf)
SPACING-
2-M
CSI.
DEFL.
in (Joe)
Wall
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC
0.31
Vert(LL)
n/a -
n/a
999
TCDL 10.0
Lumber DOL
1.25
BC
0.17
Vert(CT)
n/a -
We
999
BCLL 0.0
Rep Stress Ina
YES
WB
0.14
Haz(CT)
0.00 4
n/a
n/a
BCDL 7.0
Code FBC2017/1-P12014
Matrix-S
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing direc8y applied or 6-0-0 oc
pudins, except end verticals.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 =
12419-11-8 (min. 0-1-8)
4 =
14519-11-8 (min. 0-1-8)
5 =
414/9-11-8 (min. 0-1-8)
Max Horz
1 =
188(LC 12)
Max Uplift
4 =
-67(LC 12)
5 =
-190(LC 12)
Max Grav
1 =
124(LC 1)
4 =
145(LC 1)
5 =
414(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
TOPCHORD
1-2=-314/128
WEBS
2-5=-330/474
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf, h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and 66ExTedo7(2) zone; cantilever left and -right— —
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcument with any other live loads.
4) . This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 67 lb uplift at
joint 4 and 190 lb uplift at joint 5.
LOAD CASE(S)
Standard
PLATES GRIP
MT20 2441190
Weight: 40 lb FT=10%
o� a»T,mb.+wmeia trOm�e.m cs
Qrw.mrwnM1,....m�rynontpussea;aalw'vcEA£w>ERbs.bcu+uruaswnrbFa111JremuaromcoEruan-.am,.v+hm%wv=n•+....a,..e,a..
&�.vlyErye�,nbmb�els4.w1A6�aM�;i�rmdmwTW,maywNyco-iewlugakf YJ tauW trwTODbGrfd u. irva OnCn Erpnw�ip r�LB:uCT.Erg4.s}.Mrimvyl➢Dn�n
JaMBOunUp PE6t8W
ee}eno Cb P^Vm'��G�.✓MR+OaM1,bbHb�Jndwu�M TrmdP4lone�lDOM/.uJ IP4tlle>.F+��9�.wL^imGtim.w�LSNYwgaerela�T TrvnMM'�%/LbMmpn��YdM
WT<If ibuN EN'>�9LFif815
ow.u.wow.�moaaa.ro..we+T*�ve.4v+be.,n,mewcG m. mc. rel auvw..rum+.Tn.bra+wwroo.mwwaw.wwT.s..'=<at+or.dim:�e..i*wa:nmm�.aw.e.wrrw�o�a<nr
a.m.ma,+.vv..mR.acwao a+�m.rwaewT�.es..wm+.sewer...'aws�,aWm,,,�.r+s+me.r�,,..v�lasWw�+mm.esxw.r.+f..q.are.w+c mfa.�...w,.woR*us.•.e
usl sll+a m.a.
RPimm.RX918
WIFid4�iNnTWG"b.EP�vME�P�NT,ua IIMo<e,+. wSecpay.h+iW M1 W0t1 WnM�N^A�ntrC>I�M+.Mctl.T+K<'br Eti+�Ia NOS9�&dtiq.Gryvim Tn®6MwE^i.
�mJM�E?II: OH
DaM1: O&b5J18
'tNaLYabma e+OBWeCn Yhl.ppJnpn10 ZI5M1RIXQTnmta-I�Mb- m6PtlebamuJNmJ>ti�M1siAr�eC.HIbrtRa MSeCFmnmu.G6l RwlTmsm
Job
Truss
Truss Type
City
Ply
028
A0589
WRMSCM1560B1L
VM14
Valley
1
1
Job Reference (optional)
A-1 Roof Trusses, Fort Plerce, FL 34946. design@alauss.com Run: 8.210 s May 18 2018 Print: 8210 s May 18 2018 MiTek Industries, Inc. Thu Aug 22 13:41:32 2019 Page 1
I D:Id_OOXyyT6IBi_TXoljwHHzefvK-hutR7gmlXjzWOA80XZIcheIK4AKnRZvd EZp70Uyi16n
12-0-0
12-0-0
3.4 4
1.5x4 II
1.Sx4 II
3
1.5x4 II
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
Udell
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.44
Vert(LL)
We -
n/a
999
MT20 2441190
TCDL 10.0
Lumber DOL
1.25
BC 0.30
Vert(CT)
n/a -
n/a,
999
BCLL 0.0 '
Rep Stress Incr
YES
WS 0.16
Horz(CT)
0.00 4
n/a
n/a
BCDL 7.0
Code FBC2017/fP12014
MatrixS
Weight: 48 lb FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 64)-0 oc
puriins, except end verticals.
BOTCHORD
Rigid ceiling directly applied or 10-" oc bracing.
MTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
1 =
153/11-11-8 (min. 0-1-8)
4 =
174/11-11-8 (min. 0-1-8)
5 =
503111-11-8 (min. 0-1-8)
Max Horz
1 =
229(LC 12)
Max Uplift
4 =
-81(LC 12)
5 =
-232(LC 12)
Max Grav
1 =
153(LC 1)
4 =
230(LC 19)
5 =
503(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
TOP CHORD
1-2=-363/149
WEBS
2-5=402/545
NOTES-
1) Wind: ASCE 7-10; Vul[=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
4)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-M wide will fit between the
bottom chord and any other members, with BCDL =
7.Opsf.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 81 lb uplift at
joint 4 and 232lb uplift at joint 5.
LOAD CASE(S)
Standard
JUNE 20, 2019 TYPICAL HIP / KING JACK CONNECTION STDTL01 +
CORNERSET GENERAL SPECIFICATIONS
MAX LOAD: 55 psf Roof Load, 175 mph, ASCE
7-10, Exp. B, C up to 60' Mean Roof Height
and Exposure D up to 30' Mean Roof Height.
A-1 ROOF TRUSSES I j ""
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 349461 N Attach King Jack w/ (3) 16d Toe
772-409-1010 Nails @ TIC & BC
Attach End Jack's
w/ (4) 16d Toe Nails @ TC
& (3) 16d Toe Nails @ BC
0
r`
ttach Corner Jack's
d (2) 16d Toe Nails
@ TIC & BC (Typ)
Attach Corner Jack's
w/ (2) 16d Toe Nails @ TIC &
BC (Typ)
Jeml9�PE0
VTub Houu E+gab0�i pA 9t 6f 5
Y5194tie9M.
tt PI�w.R9.9.0
pale: p02VM19
FEBRUARY 17, 2017 1 ALTERNATE GABLE END BRACING DETAIL 1 STDTL03
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD
V-3'MAX.
OIAG. BRACE
AT 1/3 POINTS
IF NEEDED
IT IS THE RESPONSIBILITY OF THE BLOG.
DESIGNER OR THE PROJECT ENGINEER/ARCHITECT
TO DESIGN THE CEILING DIAPHRAGM AND ITS
ATTACHMENT TO THE TRUSSES TO RESIST ALL
OUT OF PLANE LOADS THAT MAY RESULT FROM
THE BRACING OF THE GABLE ENDS.
HORIZONTAL BRACE
(SEE SECTION A -A)
TRUSSSES
r 24' D.C.
2X6 DIAGONAL BRACE SPACED 4B'
OZ. ATTACHED TO VERTICAL WITH
(4) - 16d NAILS, AND ATTACHED TO
BLOCKING WITH (5) - IDd COMMONS.
NAIL DIAGONAL BRACE TO
PURLIN WITH TWO 16d NAILS.
2X4 PURLIN FASTENED TD FOUR
TRUSSES WITH (2) - 16d NAILS
EACH. FASTEN PURLIN TO BLOCKING
W/ (2) - 16d NAILS (MIN.).
PROVIDE 2X4 BLOCKING BETWEEN
THE TRUSSES SUPPORTING THE
\ BRACE AND THE TWO TRUSSES ON
\ EITHER SIDE AS NOTED. TOENAIL
\ BLOCKING TO TRUSSES WITH (2) -
\ 10d NAILS AT EACH END. ATTACH
DIAGONAL BRACE TO BLOCKING WITH
(5) - 10d COMMON WIRE NAILS.
ENO WALL
CEILING SHEATHING
BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES
STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED:
METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE
OF THE STRUCTURAL GABLE AND FASTEN PER THE
FOLLOWING NAIL SCHEDULE.
METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL
MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING
NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG
SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL
NAILING SCHEDULE:
- FOR WIND SPEEDS 12D MPH (ASCE 7-9B, 02, 05), 150 MPH (ASCE
7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (131'
X 3') NAILS SPACED 6' D.C.
- FOR WIND SPEEDS GREATER 120 MPH (ASCE7-98, 02, 05), 150
MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d
(131'X3') NAILS SPACED 6' O.C. (2X4 STUDS MINIMUM).
MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. AL'
BRACING METHODS SHOWN ON PAGE 1 ARE VALID
AND ARE TO BE FASTENED TO THE SCABS OR
VERTICAL STUDS OF THE STANDARD GABLE TRUSS
ON THE INTERIOR SIDE OF THE STRUCTURE.
IdI41
STRUCTURAL AN AOEOUADIAPHRAGM OR ETHER METHOD OF BRACING
GABLE TRUSS It
MUST BE PRESENT
SENT TO PROVIDE FULL LATERAL SUPPORT OF
THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS.
THE BRACING SHOWN IN THIS DETAIL IS FOR
VERTICAL/STUDS ONLY.
i
NOTE: THIS DETAIL IS TO BE USED ONLY FOR/
STRUCTURAL GABLES WITH INLAYED
STUDS. TRUSSES WITHOUT INLAYED
STUDS ARE NOT ADDRESSED HERE. _
STANDARD GABLE
I TRUSS
JULY 17, 2017
STANDARD PIGGYBACK TRUSS
STDTL04
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
THIS DETAIL IS APPLICABLE FOR THE FOLLOWING WIND CONDITIONS:
ASCE 7-98, ASCE 7-02, ASCE 7-05, ASCE 7-10 WIND STANDARDS UNDER ALL ENCLOSURE AND EXPOSURE
CONDITIONS AS LONG AS NO UPLIFT EXCEEDS 377 LBS. REFER TO ACTUAL PIGGYBACK TRUSS DESIGN
DRAWING FOR UPLIFTS.
NOTE: THIS DETAIL IS VALID FORONE PLYTRUSSES SPACED 24' O.C. OR LESS.
PIGGYBACK TRUSS
REFER TO ACTUAL TRUSS DESIGN DRAWING FOR
ADDITIONAL PIGGYBACK TRUSS INFORMATION.
SPACE PURLINS ACCORDING TO THE MAXIMUM
SPACING ON THE TOP CHORD OF THE BASE TRUSS
(SPACING NOT TO EXCEED 24' D.C.) A PURLIN
TO BE LOCATED AT EACH BASE TRUSS JOINT.
ATTACH PIGGYBACK TRUSS TO THE BASE TRUSS WITH 2' X 8-
TEE-LOCK MULTI -USE CONNECTION PLATES SPACED 48' O.C. PLATES
SHALL BE PRESSED INTO THE PIGGYBACK TRUSS AT 48' O.C.
STAGGERED FROM EACH FACE AND NAILED TO THE BASE TRUSS WITH
FOUR (4) 6d (1.5' X 0.099') NAILS IN EACH PLATE TO ACHIEVE A MAXIMUM
UPLIFT CAPACITY OF 377 LBS. AT EACH 2' X 8' TEE -LOCK MULTI -USE
CONNECTION PLATE. (MINIMUM OF 2 PLATES)
ATTACH EACH PURLIN TO THE TOP CHORD OF
THE BASE TRUSS.
(PURLINS AND CONNECTION BY OTHERS)
BASE TRUSS -
REFER TO ACTUAL TRUSS DESIGN DRAWING FOR
ADDITIONAL BASE TRUSS INFORMATION.
.��vaow�re Q
N1oMIL-... LA91BI!
ft I .. M.
D.%mro.S'I..
G66 PM121'SL18
JULY 17, 2017 I TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34M
772-009-1010
VALLEY TRUSS
(TYPICAL)
SECURE VALLEY TRUSS
W/ ONE ROW OF 10d
NAILS W O.C.
GABLE END, COMMON
TRUSS, OR GIRDER
TRUSS
ATTACH 2X4 CONTINUOUS #2
SYP TO THE ROOF W/ TWO USP
WS45 (1/4' X4.5-) WOOD SCREWS
INTO EACH BASE TRUSS.
DETAIL A
GENERAL SPECIFICATIONS:
1. NAIL SIZE =3'X 0.131'=10d
2. WOOD SCREW = 4.5' WS45 USP OR EQUIVALENT.
3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES.
4. INSTALL VALLEY TRUSSES (24- O.C. MAXIMUM) AND
SECURE TO BASE TRUSSES AS PER DETAIL"A.
S. BRACE VALLEY WEBS IN ACCORDANCE WITH THE
INDIVIDUAL DESIGN DRAWINGS.
6. NAILING DONE PER NDS-01.
7. VALLEY STUD SPACING NOT TO EXCEED 48' O.C.
BASE TRUSSES
_E END, COMMON
3S, OR GIRDER TRUSS
TRUSS CRITERIA:
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6112
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD =50 PSF
MAXSPACING=24° O.C. (BASE AND VALLEY)
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
JeM BPmI�PEBa�9
�++�.F+aa�TMecnvs+s
NS+SI I+w BM.
FI. Pbrm,ft9°9,6
Om: 04Rh010
FEBRUARY 5, 2018 I TRUSSED VALLEY SET DETAIL I STDTL06
GENERAL SPECIFICATIONS:
1. NAIL SIZE=3'X0.131'=10d
2. WOOD SCREW = 3' WS3 USP OR EQUIVALENT.
3. INSTALL VALLEY TRUSSES (24.O.C. MAXIMUM) AND SECURE PER DETAIL
.I 'A'.
C' 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN
DRAWINGS.
5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT
TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING.
A-1 ROOF TRUSSES 6. NAILING DONE PER NDS-01.
4451 ST. LUCIE BLVD. GABLE END, COMMON 7. VALLEYSTUD SPACING NOTTO EXCEED 48' O.C.
FORT PIERCE, FL 34946 TRUSS,ORGIRDER
772409-1010 I TRUSS
SECURE
W/(
VALL`YRUSS I� I 1 1 II II II BASE TRUSSES
DETAIL A
(NO SHEATHING) N.T.S.
GABLE END, COMMON
TRUSS, OR GIRDER
P 12
r VALLEY TRUSS TRUSS
�\ (TYPICAL)
SEE DETAIL 'A'
BELOW (TYP.)
ATTACH 2X4 CONTINUOUS #2
SYP TO THE ROOF W/TWO USP
WS3 (1/4' X 3') WOOD SCREWS
INTO EACH BASE TRUSS.
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
CATERGORY II BUILDING
EXPOSUREC
WIND DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD =50 PSF
MAX SPACING = 24' O.C. (BASE AND VALLEY)
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
J Bp WPE6
nL^b Nwv@gbae�y L/.3�6i5
u5t@4oe Bhp
FLPbRq Fl3L9,8
0814 OB2Ldll9
JULY 97, 2017
I I% V ". V1 V V 1 V L I /111...
IGH WIND
STDTL07
A-1 ROOF TRUSSES
44S7 ST. LUCIE BLVD.
FORT PIERCE, FL 34W
772-409-1010
ATTA(
WIND DESIGN PER ASCE 7-98, ASCE 7-
WIND DESIGN PER ASCE 7-10: 170 MPI
MAX MEAN ROOF HEIGHT = 30 FEET
CATERGORY II BUILDING
EXPOSURE B OR C
WIND DURATION OF LOAD INCREASE:
MAX TOP CHORD TOTAL LOAD = 50 PS
MAX SPACING =24' O.C. (BASE AND V/
SUPPORTING TRU55t5 UIKLU I LY UNULK VALLEY I KU35tJ MUS I Ot
DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2'-10' ON AFFECTED
TOP CHORDS.
NOTES:
1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES.
2. THIS DETAIL IS NOT APPLICABLE FOR SPFS SPECIES LUMBER.
NON -BEVELED
BOTTOM CHORD
FOR BEVELED BOTTOM
CHORD, CLIP MAY BE APPLIED
TO EITHER FACE.
CLIP MAY BE APPLIED
TO THIS FACE UP TO A
MAXIMUM 6/12 PITCH NON -BEVELED
BOTTOM CHORD
CLIP MUST BE APPLIED TO
THIS FACE WHEN PITCH
EXCEEDS 6/12 (MAXIMUM
12/12 PITCH)
.avaow�reszeon
xmoa xoou Fnpaemme cn sI m l
R.R
«s, ILeI.
916
one: ovurzole
FEBRUARY 17, 2017
STANDARD GABLE END DETAIL
STDTL08
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
77A4031010
TYPICAL 2X4 L-BRACE
NAILED TO 2X4 VERTICALS
W/lOd NAILS, S' O.C.
VERT
STUD
F9dmil01J2J
TRUSS GEOMETRY AND CONDITIONS
SHOWN ARE FOR ILLUSTRATION ONLY.
� DIAGONAL BRACE 4' - 0' D.C. MAX.
SEE INDIVIDUAL ENGINEERING DRAWINGS
FOR TRUSS DESIGN CRITERIA.
12
Q VARIES TO COMMON TRUSS
* DIAGONAL BRACING - ** L - BRACING REFER
REFER TO SECTION A -A TO SECTION B-B
v
24' MAX.
NOTE:
1. MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS.
2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO
BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT.
3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG.
ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF
SYSTEM.
4. L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR. SP #3 OR
BETTER WITH ONE ROW OF 10d NAILS SPACED 6' D.C.
5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM
AT 4'-0'OL.
6. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN
WITH 16d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE LOCATED AT
THE MIOSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE
STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A)
7 GABLE STUD DEFLECTION MEETS DR EXCEEEDS L/240
VERTICAL
2X6 SP OR SPF
STUDVBRACE
42 DIAGONAL
BRACE
(4) - 16d
NAILS16d
NAILS
SPACED 6' O.C.
(2) 10d NAILS
INTO 2X62X6
SP OR
SPF #2
2X4 SP OR
SPF #2L
HORIZONTAL
NAILED TO
RTICALS
SECTION A -A
W/(4) - SOd NAILS
PROVIDE 2X4 BLOCKING BETWEEN
THE FIRST TWO TRUSSES AS NOTED.
TOENAIL BLOCKING TO TRUSSES
WITH (2) - 10d NAILS AT EACH END.
ATTACH DIAGONAL BRACE TO
BLOCKING WITH (5) - 10d NAILS
(4) Ed NAILS MINIMUM,
PLYWOOD SHEATHING TO
2X4 STO SPF BLOCK
B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. OIAG. BRACE
S. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS
TRUSSES. IF NEEDED
10. 10d AND 16d NAILS ARE 0131'X3.0' AND 0131'X35' COMMON WIRE NAILS
RESPECTIVELY.
11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12
BY SPIB/ALSC.
MINIMUM STUD
SIZE SPECIES
AND GRADE
STUD
SPACING
WITHOUT
BRACE
2X4
L - BRACE
DIAGONAL
BRACE
(P) DIAGONAL
BRACES AT
1/3 POINTS
MAXIMUM STUD LENGTH
2X4SP#31STUD
12'O.C.r1l56-11
66-11
11-1-13
2x4sP #31sND
i6'O.C.49-12
66-11
9-10-15
2X4SP#31STUD
24'O.C.3.11-3
54-12
8.1-2
2X4SP#2
12.O.C.56-11
66-11
11-8-14
2X4 SP #2
16'O.C.4.9-12
66-11
10.8-0
-2X4SP#2- -
24'-O.C--3-1"
—
- -&2-9
9-3-13
DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T-BRACE ATTACHED TO ONE
EDGE. DIAGONAL BRACES OVER 12' - 5' REQUIRE 2X4 I -BRACES ATTACHED TO
BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE
WITH 10d NAILS 6' D.C. WITH 3' MINIMUM'END DISTANCE. BRACE MUST COVER
SOX OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2.
ROOF
SHEATHING
(2) - lOd
NAILS
TRUSSES 8.24' OZ.
2X6 DIAGONAL BRACE
SPACED 48' OL. ATTACHED
TO VERTICAL WITH (4) -
16d NAILS, AND ATTACHED
TO BLOCKING WITH (5) -
10d NAILS.
HORIZONTAL BRACE
(SEE SECTION A -A)
END WALL
MAX MEAN ROOF HEIGHT=30 FEET
EXPOSURE B OR C
ASCE 7-10 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING.
DURATION OF LOAD INCREASE: 1.60 CONNECTION OF BRACING IS BASED ON MWFRS.
FEBRUARY 17, 2017 I WITH 2X BRACE ONLY I STDTL09
NOTES:
T-BRACING / I -BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING
IS IMPRACTICAL. T-BRACE / I -BRACE MUST COVER BOX OF WEB LENGTH.
THIS DETAIL NOT TO BE USED TO CONVERT T-BRACE / I -BRACE WEBS TO
CONTINUOUS LATERAL BRACED WEBS.
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
NAILING PATTERN
T-BRACE SIZE
NAIL SIZE
NAIL SPACING
2X4 OR 2X6 OR 2X8
10d
6' O.C.
NOTE NAIL ALONG ENBRE LENGTH OF T-BRACE / I -BRACE (ON
TWO-PLY TRUSSES NAIL TO BOTH PLIES)
BRACE
SIZE FOR ONE -PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 20
2X4 T-BRACE
2X4 I -BRACE
2X6
2X6 T-BRACE
2X6 1-BRACE
P2X8
2X8 T-BRACE
2X8 I -BRACE
BRACE
SIZE FOR TWO-PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 2X4
2X4 T-BRACE
2X4 I -BRACE
2X6
2X6 T-BRACE
2X6 I -BRACE
2X8
2X8 T-BRACE
2X8 I -BRACE
T-BRACE / I -BRACE MUST BE SAME SPECIES
AND GRADE (OR BETTER) AS WEB MEMBER.
NAILS - NAILS
WEB
NAILS WEB
I —BRACE T—BRACE
SECTION DETAILSaPE
Wmb xou5e FNMITa CA.81 s
uses �asiw.
FL P..ft9'NB
Dab: OflR12019
FEBRUARY17,2017 1 LATERAL BRACING RECOMMENDATIONS I STDTL10
TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS,
2X6 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY B TO 10 FEET
ALONG A FLOOR TRUSS.
W.—
NOTE 1: 2X6 STRONG13ACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE
TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY
A-1 ROOF TRUSSES OF THE METHODS ILLUSTRATED BELOW.
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946 NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE
772-409-1010 BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS
FROM ENO TO ENO, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY
CONNECTED, BY OTHERS, AT THE ENDS.
INSERT WOOD SCREW THROUGH
OUTSIDE FACE OF CHORD INTO
EDGE OF STRONGBACK (DO NOT
USE METAL FRAMING C ATTACH TO VERTICAL C ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS)
ANCHOR TO TO TOPATTACH A CHORO \NA IS (D131WITH 31X 3')Od SCAB WITH NAILS (0132'3X 3'l 0d rNATTACH AILS TO VERTICAL
\ \ WEB WITH (3) - IDd
BLOCKING BEHIND THE VERTICAL
WEB IS RECOMMENDED WHILE
NAILING THE STRONGBACK
USE METAL FRAMING ATTACH TO VERTICAL
ANCHOR TO ATTACH WEB WITH (3) - 10d
TO BOTTOM CHORD NAILS (0131' X 3')
ATTACH 2X4 VERTICAL
TO FACE OF TRUSS.
FASTEN TO TOP AND
BOTTOM CHORD WITH
(2) - IDd NAILS (0131'
X 3) IN EACH CHORD
ATTACH TO CHORD
WITH (2) #12 X 3'
WOOD SCREWS
(0.216' DIAJ
ATTACH TO VERTICAL INSERT SCREW THROUGH
SCAB WITH (3)- 10d OUTSIDE FACE OF CHORD INTO
NAILS (0131' X 3') EDGE OF STRONGBACK (00 NOT
USE DRYWALL TYPE SCREWS)
TRUSS 2X6 {.� 4' - 0' WALL
STRONGBACK I (TYPICAL SPLICEI— (BY OTHERS)
I I THE STRONGBACKS SHALL BE SECURED -AT -THEIR -ENDS TO AN ADEQUATE SUPPORT, —
DESIGNED BY -OTHERS. —IF - SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB
CENTERED ON THE SPLICE AND JOINED WITH (12) - IDd NAILS (0131' X 31)
EQUALLY SPACED.
ALTERNATE METHOD OF SPLICING:
OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) -
lOd NAILS (D131' X 39 STAGGERED AND EQUALLY SPACED (TO BE USED ONLY
WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL).
BLOCKING
(BY OTHERS)
FEBRUARY 17, 2017
LATERAL TOE -NAIL DETAIL
STDTL11
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 349M
772409-1010
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45' WITH THE MEMBER
AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN
THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER ENO AS
SHOWN).
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL
BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO
SPECIES FOR MEMBERS OF DIFFERENT SPECIES.
TOE -NAIL SINGLE SHEAR VALUES
PER NOS 2001 (LB/NAIL)
DIA
SP
OF
HF
SPF
SPF-S
.131
88.0
80.6
69.9
68.4
59.7
o.135
93.5
85.6
74.2
72.6
63.4
J
in
.162
108.8
99.6
86.4
84.5
73.8
ri
.128
74.2
67.9
58.9
57.6
50.3
cv
o
.131
75.9
69.5
60.3
59.0
51.1
J
N
.148
81.4
74.5
64.6
63.2
52.5
ri
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) - 16d NAILS (0162' DIA. X 35') WITH SPF SPECIES BOTTOM CHORD
FOR LOAD DURATION INCREASE OF 1.15:
3 (NAILS) X 84-9 (LB/NAIL) X 115 (DOL) = 2915 LB MAXIMUM CAPACITY
ANGLE MAY
VARY FROM
30' TO 60'
45.00'
ANGLE MAY
VARY FROM
30' TO 60'
THIS ❑ETAIL IS ONLY APPLICABLE TO
THE THREE END DETAILS SHOWN BELOW.
SIDE VIEW
(2X3) 2 NAILS
NEAR SIDE
IXF
NEAR SIDE
SIDE VIEW.
(2X4) 3 NAILS
NEAR SIDE
NEAR SIDE
NEAR SIDE
45.00'
SIDE VIEW
(2X3) 2 NAILS
NEAR SIDE
NEAR SIDE
NEAR SIDE
NEAR SIDE
ANGLE MAY
VARY FROM
30' TO 60'
45.000
FEBRUARY 17, 2017 1 UPLIFT TOE -NAIL DETAIL I STDTL12
A•1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772199A010
THIS DETAIL SHALL BE USED FOR A CONNECTION
RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER
IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS.
TOE -NAIL WITHDRAWAL VALUES
PER NOS 2005 (LB/NAIL)
DIA.
SP
OF
HF
SPF
SPF-S
LD
z
.131
59
46
32
30
20
-1
.135
60
4B
33
30
20
U7
.162
72
58
39
37
25
J
X:
U
.12B
54
42
2B
27
19
0
Z
Z
.131
55
43
29
213
19
LU
J
U)
.148
62
4B
34
31
21
J
N
r7
Z
.120
51
39
27
26
17
U'
Z
.12B
49
3B
26
25
17
0
.131
51
39
27
25
17
e
M)
.1 4B
57
44
31
28
20
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30' WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE
MEMBER END AS SHOWN.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION.
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) - l6d NAILS (0162' DIA. X 35') WITH SPF SPECIES TOP PLATE
FOR WIND OOL OF 133:
3 (NAILS) X 37 (LB/NAIL) X 133 (DOL FOR WINO) = 14B LB MAXIMUM. ALLOWABLE UPLIFT REACTION DUE TO WIND
FOR WINO DOL OF 1.60:
3 (NAILS) X 37 (LB/NAIL) X 1.60 (DOL FOR WINO) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND
IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LBS (177 LBS) BUILDING
DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION.
000 USE (3) TOE -NAILS ON 2X4 BEARING WALL
000 USE (4) TOE -NAILS ON 2X6 BEARING WALL
NEAR SIDE
FAR S:
lE
TOP -PLATE
OF WALL
VIEWS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY
IL
NAIL
NAIL
SIDE VIEW
END VIEW
RUARY 5, 2016
TYP 2x2 NAILER ATTACHMENT I STDTL13
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-469-1616
1 WRACI
2x2 NAILER ATTACHMENT
GENERAL SPECIFICATIONS
MAX LOAD: 55 psf Roof Load, 170 mph, ASCE
7-10, 29'-0" Mean Height, Exp. B, C or D.
vows �" .. ueuw,me a ai e+s
R Rum,R.L916
April 11, 2016
TYPICAL ALTERNATE BRACING DETAIL
FO EXTERIOR FLAT GIRDER TRUSS
STDTLI4
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34945
772-409-1010
(4) 12d
TRUSS 2411 O.C.
UPLIFT CONNECTION
(SEE ROOF TRUSS)
EXTERIOR FLAT
GIRDER
12
VARIES
(4) 12d
MAX 3011 (21-6")
2x6 #2 SP (Both Faces)
2411 O.C.
SIMPSON H5
JwISp KW
.H �"31615
IJ51 sl,wma.
w veR..n Wm; W2Y2J1910
• STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND STDTL15
FEBRUARY 17, 2017 DAMAGED OR MISSING CHORD SPLICE PLATES
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
TOTAL NUMBER
OF NAILS EACH
SIDE OF BREAK *
X
(INCHES)
MAXIMUM FORCE (LBS) 15% LOAD DURATION
SP
OF
SPF
HF
2X4
2X6
2X4
2X6
2X4
2X6
2X4
2X6
2X4
2X6
20
30
24'
1 1706
2559
1561
2342
1320
1980
1352
2028
26
39
30'
2194
3291
2007
3011
1697
2546
1738
2608
32
48
36'
2681
4022
2454
3681
2074
3111
2125
3187
38
57
42'
3169
4754
2900
4350
2451
3677
2511
3767
44
68
48'
3657
5485
3346
5018
2829
4243
2898
1 347
• DIVIDE EQUALLY FRONT AND BACK
ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF
THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE
ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (131' OIA. X 3').
STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN
THE MAIN MEMBER. USE A MIN. 3' MEMBER ENO DISTANCE.
THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS)
THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C
v � 2 00
11
l
c
.F REAK .
• Uld NAILS NEAR SIDE
+ 10d NAILS FAR SIDE
S' MIN
THE LOCATION OF THE BREAK MUST BE GREATER
THE REQUIRED X DIMENSION FROM ANY PERIMETER
AND A MINIMUM OF 6' FROM ANY INTERIOR JOINT
DO NOT USE REPAIR FOR JOINT SPLICES
NOTES:
1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR
DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE
TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN
THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF
SUPPORTING THE LOADS INDICATED.
2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR
AND HELD IN PLACE DURING APPLICATION OF REPAIR.
3. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID
UNUSUAL SPLITTING OF THE WOOD.
4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID
LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES.
S. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY.
6. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS.
TRUSS CONFIGURATION
AND BREAK LOCATIONS
FOR ILLUSTRATIONS ONLY
THAN OR EQUAL TO
BREAK OR HEEL JOINT
(SEE SKETCH ABOVE).
.tine oam �ezms
xndoxduemBaww
ust s��e B+a.
R Ram.R 31918
UCc OVIYMiB
FEBRUARY17,2017 1 SCAB APPLIED OVERHANGS I STDTL16
r
e
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1919
TRUSS CRITERIA:
LOADING: 40-10-0-10
DURATION FACTOR: 115
SPACING: 24' D.C.
TOP CHORD: 2X4 OR 2XG
PITCH: 4/12 - 12/12
HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL
ENO BEARING CONDITION
NOTES:
1. ATTACH2X-SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS
WITH TWO ROWS OF 10d COMMON WIRE NAILS. (148' DIA. X 3') SPACED 6' O.C.
2. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH
AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO
AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES.
2X SC
NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED
WHEN OVERHANG HAS BEEN BROKEN OFF.
IMPORTANT
THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED-24' D.C. MAXIMUM AND HAVING PITCHES_BETVEEN-4/12-AND 12/12 AND TOTAL TOP CHORD
LOADS NOT -EXCEEDING "50 PSF.
TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY.
REFER TO INDIVIDUAL TRUSS DESIGN
FOR PLATE SIZES AND LUMBER GRADES
� 4
A-1 ROOF
TRUSSES
A FLORIDA CORPORATION
RE: Job WRMSCM1560B1L
No.
Seal # I
Truss Name
Date
37
A0280583 I
T06
8122119
38
A0280584
T06A
8/22119
39
A0280585
T06SGE
8/22/19
40
A0280586
VM08
8/22/19
41
A0280587
VM10
8122119
42
A0280588
VM12
8/22119
43
A0280589
VM14
8/22/19
44
STDL01
STD. DETAIL
8/22/19
45
STDL02
STD. DETAIL
8122119
46
STDL03
STD. DETAIL
8/22119
47
STDL04
STD. DETAIL
8/22/19
48
STDL05
STD. DETAIL
8/22/19
49
STDL06
STD. DETAIL
8/22119
50
STDL07
STD. DETAIL
8122119
51
STDL08
STD. DETAIL
8/22/19
52
STDL09
STD. DETAIL
8IM19
53
STDL10
STD. DETAIL
8122119
54
STDL11
STD. DETAIL
8122119
55
STDL12
STD. DETAIL
8/22/19
56
STDL13
STD. DETAIL
8/22119
57
STDL14
STD. DETAIL
8122119
58
STDL15
STD. DETAIL
8122119
59
STDL16
STD. DETAIL
18122119
Lumber design values are in accordance with ANSIITPI 1-2014 section 6.3
These truss designs rely on lumber values established by others.
J&OBOnI�PE6p M
µ9W lbueeErybue�np U9t6f6
Page 2 of 2 D. s RUo
R Reru.R&paB
Otle: 08RYettB