HomeMy WebLinkAboutSOIL NUCLEAR GAUGEArdemanSoil Nuclear Gauge
& ASSOCIates, It1C. Permit # 1910-0085
Report Date: 12/20/2019
Port SL Lucie Branch Test Method: ASTM D 6938
Benda CA No. 59W
Q0 NW Ccnro Piece, Unil1
Pen SL Luoe, FL U966
Prwre: M-876-0072
Client:
Rarer Development Corp.
3725 S. East Ocean Boulevard, Suite 101
Stuart, FL 34996
Project: ICj 10 `(DOK
113-15-66-5434B
Momingside Residential Lots SCANNED
Fort Pierce BY
Fort Pierce, FL
St. Lucie County
Teat Results
Test#
Retest
Of
Test
Date
Proctor ID
Method
Sall
Classification
Optimum
Moisture
%
Maximum
Dry Density
c
In Place
Moisture
%
In Place
Dry Density
c
Probe
Depth
In
Percent
Compaction
Min Comp.
%
Remark
240
12112/19
19.122
A
—
12.0
112.0
10.8
110.6
12
99
98
Pass
241
12/12119
19-122
A
—
12.0
112.0
11.3
112.2
12
100
98
Pass
242
12/12/19
19-122
A
—
12.0
112.0
10.4
111.0
12
99
98
Pass
243
12/12119
19-122
A
—
12.0
112.0
10.2
110.9
12
99
98
Pass
Test Information
Test#
Test Location
Elevation
I Reference
Gauge
Make/Model ISN/Calibrated
Field Technician
240
Footings: Footings for Lot 57 at 9617 Rainwood Court. NW End of Footings
-1.0
Bottom of footings
CPN I MG-31 M340507395 /
Tech, Port St. Lucie
241
Footings: Footings for Lot 57 at 9617 Rainwood Court. SE End of Footings
-1.0
Bottom of footings
CPN / MC-31 M340507395 /
Tech, Port St. Lucie
242
Other. House Pad for Lot 57 at 9617 Rainwood Court. SW End of House Pad
2.0
Bottom of footings
CPN / MG-31 M340507395 /
Tech, Port St. Lucie
243
Other: House Pad for Lot 57 at 9617 Rainwood Court. NE End of House Pad
2.0
Bottom of footings
CPN / MC-31 M340507395 /
Tech, Port St. Lucie
Remarks Comments
Pass: Density Pass Tests are "Direct Tiansn9sslon" (Method A) unless probe depth is noted as
°eackseatter. Gauge calibration data on /Ve with the testing agency.
This item has been digitally signed and sealed by Branch
Manager Dan J. Zrallack, P.E. on Dec 20, 2019 using a
Digital Signature.
Printed copies of this document are not considered signed
and sealed and the SHA authentication code must be
verified on any electronic copies.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 1
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN(
OUR WRITTEN APPROVAL.