Loading...
HomeMy WebLinkAboutCERTIFICATE - DESIGN LOAD COMPLIANCEProject Name: Project Address: Permit SCANNED BY Planning& Development Services Department St. Lucie County Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance BECKER - SUNFLOWER ESCAPE, LLC 1247 NETTLES BLVD Type: Construction Type: INSTRUCTIONS FOR USE: o This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition Any accessory structure requiring a building permit Any non-residential structure. * Note: Form not required for Interior renovations provided that no exterior structural elements are affected and certain minor building permits atthe discretion of the local building official. Contactthe # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida BUILDING Code Sixth Edition with 2017 Supplements using ASCE 7-10 2. Structure Designed as'(check one): _Enclosed _Partially Enclosed X Open 3. Risk Category:_I X II _III_IV Exposure Category:_BC X D 4. Design Wind Velocity 165 mph ASD X LRFD End Zone Width: 1 ft 5. Mean Roof Height 5'+/- DECK HEIGHT it Roof Pitch: :12 Parapet: It 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly labelonall plan openings): Zone 1: Zone 2: Zone 3: Zone 4:+50.6/-64.1 Zone 5:+70.11-74.5 Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: 40 PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: DANIEL PAUL RETHERFORD 72451 Print Name 1}!. e' Y ��ert'E"Co. P , . 1402 HARTMAN ROAD, FORT PIERCE, FL 34947 Company Name &Address REVIEWED FOR CODE COMPLIANCE ST. LUCIE COrUTY SOCC1d�l(1f11