HomeMy WebLinkAboutCERTIFICATE - DESIGN LOAD COMPLIANCEProject Name:
Project Address:
Permit
SCANNED
BY
Planning& Development Services Department St. Lucie County
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
BECKER - SUNFLOWER ESCAPE, LLC
1247 NETTLES BLVD
Type: Construction Type:
INSTRUCTIONS FOR USE:
o This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
Any accessory structure requiring a building permit
Any non-residential structure.
* Note: Form not required for Interior renovations provided that no exterior structural elements are affected and
certain minor building permits atthe discretion of the local building official. Contactthe # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida BUILDING Code Sixth Edition with 2017 Supplements using ASCE 7-10
2. Structure Designed as'(check one): _Enclosed _Partially Enclosed X Open
3. Risk Category:_I X II _III_IV Exposure Category:_BC X D
4. Design Wind Velocity 165 mph ASD X LRFD End Zone Width: 1 ft
5. Mean Roof Height 5'+/- DECK HEIGHT it Roof Pitch: :12 Parapet: It
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly labelonall plan openings):
Zone 1: Zone 2: Zone 3: Zone 4:+50.6/-64.1 Zone 5:+70.11-74.5 Garage:
7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF
Dock: 40 PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
DANIEL PAUL RETHERFORD 72451
Print Name 1}!. e' Y
��ert'E"Co. P ,
.
1402 HARTMAN ROAD, FORT PIERCE, FL 34947
Company Name &Address REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COrUTY
SOCC1d�l(1f11