Loading...
HomeMy WebLinkAboutCERTIFICATE - DESIGN LOAD COMPLIANCEProject Name: Project Address: Planning& Development Services Department SCANNED Building & Code Regulations Division St. Luce County 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 ry Certification for Design Load Compliance PERZEE 414 NETTLES BLVD Permit#: Occupancy Type: Construction • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida BUILDING Code Sixth Edition with 2017 Supplements using ASCE 7-10 2. Structure Designed as (check one): _Enclosed _Partially Enclosed X Open 3. Risk Category:_I X II _III_IV Exposure Category:_8C XD 4. Design Wind Velocity 165 mph ASD X LRFD End Zone Width: 1 ft S. Mean Roof Height 4' +/7 DECK HEIGHT It Roof Pitch: :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on losgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4:+60.6664.1 Zone 5:'70.1/-74.5 Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: 40 PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes_ Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie Co,A%Llti IMNP�t structural elements depicted on these plans provide adequate resistance to the design �*�� yob �•O%� DANIEL PAUL RETHERFORD 72451 ��. !nN Print Name Cent # '60' agfe, Da d seal 1402 HARTMAN ROAD, FORT PIERCER, FL 3 94 �'j�/3��rr/�; .016 .*`��• Company Name &Address REVIEWED FOR Revrs�dd2/t1 2 % CODE C®�lIPI�fAI!!CE /!!t(II)' ST• LUCIE COMY BOCC