Loading...
HomeMy WebLinkAboutEVALUATION REPORTOCT 0 2 2019 EVALUATION REPORT OF, Lucie SCANNED UNION CORRUGATING COMPANY BY '26 GA. 5V PANEL' St. Lucie County C� FLORIDA BUILDING CODE 6TH EDITION (2017) 0 0 - FLORIDA PRODUCT APPROVAL FL 7271.5-R4 Fg�� C,0, ROOFING J� METAL ROOFING 7ke�®� GO SV SL®� Prepared For: Union Corrugating Company 701 S. King St. Fayetteville, NC 28301 Telephone: (910) 483-0479 Fax: (910) 483-1091 Prepared By: Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (866) 366-1543 This report consists of Evaluation Report (3 Pages including cover) Installation Details (1 Page) Report No. C2174-5 Date: 8.23.2017 'Z21.2C FL 7271.5-R4 C2174-5 8.23.2017 Page 2 of 3 Manufacturer: Union Corrugating Company Product Name: 5V Panel Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 15/32" thick APA rated plywood or min. W thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017. Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1 Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2 Design Uplift Pressure: 63.75 psf for Fastener Pattern 1 in 15/32" thick plywood deck (Factor of Safety = 2) 106.5 psf for Fastener Pattern 2 in 15/32" thick plywood deck 150.0 psf for Fastener Pattern 2 in 19/32" thick plywood deck Panel Attachment: 49-15 or #10-14 xl.5" long wood screw with washer @ max 16" o.c. through panel flat. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". Fastener Patterns 1 2 fasteners per panel width. (One each adjacent to overlap and intermediate ribs) Fastener Patterns 2 4 fasteners per panel width. (One each adjacent to overlap and underlap ribs and on both sides of intermediate rib) Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. FL 7271.5-R4 C2174-5 8.23.2017 Page 3 of 3 Supporting Documents: TAS 125-03 Test Reports PRI Construction Materials Technologies UCC-005-02-1, Reporting Date 2/09/12 PANEL OVERLAPSEE DETAIL 1 PANEL FASTENER PANEL FASTENER ROOF PANEL / THIS SHEEP MAX. 16' O.C. MAX. 16" O.C. n II n I n n \ / II DECK ATTACHMENT AND n UNDERIAYMENT SHALL BE INSTALLED SUPPORTS MUST BE AS PER MANUFACTURER'S INSTALLATION DESIGNED AND INSTALLED MIN. 2X_ WOOD RAFTER/JOIST/ GUl WNLS UT UIHLK] IKU95 Al MAX. Z4 U.G. FASTENER PATTERN 1 %/�&2 1s2" 0 �' PANEL OVERLAP PANEL FASTENER PANEL FASTENER ROOF PANEL SEE DETAIL 2 THIS SHEEP ® MAX. Ifi' O.C. 0MAX. 16° O.C. n II li \ 11 t DECK ATTACHMENT AND UNDERLAYMENT SHALL BE INSTALLED SUPPORTS MUST BE AS PER MANUFACTURER'S INSTALLATION DESIGNED AND INSTALLED UNDERIAYMENT UNDERIAYMENT #9-15 OR #10-14 X 1.5° LONG WOOD SCREW WITH WASHER ® MAX. 16" O.C. DETAIL 1 #9-15 OR #10-14 X 1.5" LONG WOOD SCREW WITH WASHER 0 MAX. 16" O.C. DETAIL 2 UUIULLII 26 GA PANEL PLYWOOD 15/32° THICK (MIN.) ALLOWABLE UPLIFT PRESSURE PLYWOOD THICKNESS FASTENER PATTERN PRESSURE (PST) '%2" 1 63.75 %- 2 106.5 1%2 2 150.0 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS ARE SHALL BE MINIMUM 26 GA. EFFECTIVE COVERING WIDTH —MIN 26 GA. PANEL OF PANEL = 24". 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER. THAN THE ALLOWABLE WIND LOAD TABLE. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. PLYWOOD 15/32" OR 19/32° THICK or