Loading...
HomeMy WebLinkAboutEVALUATION REPORTSCREEK TECHNICAL SERVICES, LLC EVALUATION REPORT Certificate of Authorization No. 29824 17520 Edinburgh Or Tampa, FL 33647 (813)480-3421 FLORIDA BUILDING CODE, 6T" EDITION Manufacturer: GACO WESTERN, LLC Issued June 15, 2019 200 West Mercer Street, Suite 202 Seattle, WA98119 96 www aco.c m SCANNED www.aaco.com Manufacturing Plant: Waukesha, WI St. Luciie`County /+ Quality Assurance: UL LLC (QUA9625) \C&%T e ��{� � SCOPE Category: Roofing Its Subcategory: Spray Applied Polyurethane Roof SystemCode Sections: 1507.14.2,1507.14.3,1515.1.1, 1515.1.4,1519.16,1523.6.2GOG �N Properties: Wind Resistance, Physical Properties V GPRODUCT DESCRIPTION S . `50GG Product Description - GacoRoof Foam 2733 TAS 110 and ASTM C 1029 Type III polyurethane spray applied foam that utilizes an HFC blowing agent intended for roofing applications. GacoFlex A-31 ASTM D 6083 acrylic quick -set elastomeric coating that is brush, roller or spray -applied. GacoFlex S-10 ASTM D 6694 silicone elastomeric coating that is brush, roller or spray -applied. GacoFlex S-20 ASTM D 6694 silicone solvent -free, single -component, moisture -cured, waterproof elastomeric coating that is brush, roller or spray -applied. GacoFlex S-21 ASTM D 6694 silicone solvent -free, single -component, moisture -cured, waterproof elastomeric coating that is brush, roller or spray -applied. GacoRoof GR-16 ASTM D 6694 silicone elastomeric coating that is brush, roller or spray -applied. REFERENCES Enti Report No. Standard Year Intertek Testing Services NA, Inc. (TST6781) 102206114MID-001 ASTM C 1029 2013 TAS 110 2000 FM Approvals (TST1867) 3023W FM 4470 2012 FM Approvals(TST1867) 3052963 FM 4470 2012 PRI Construction Materials Technologies (TST5878) GWI-024.02-02 ASTM D 6694 2008 PRI Construction Materials Technologies (TST5878) GWI-026-02-01 ASTM D 6694 2008 PRI Construction Materials Technologies (TST5878) GWI-042.02-01 ASTM D 6694 2008 PRI Construction Materials Technologies (TST5878) GWI-043-02-01 ASTM D 6694 2008 PRI Construction Materials Technologies (TST5878) GWI-044-02-01 ASTM D 6694 2008 PRI Construction Materials Technologies (TST5878) GWI-045-02-01 ASTM D 6083 2005e01 PRI Construction Materials Technologies (TST5878) GWI-045-02-01 Proprietary 2017 PRI Construction Materials Technologies (TST5878) GWI-052.02-01 ASTM D 2126 2015 TAS 110 2000 PRI Construction Materials Technologies (TST5878) GWI-057-02-01 ANSI/FM 4474(D) 2011 TAS 114(J) 1995 PRI Construction Materials Technologies (TST5878) GWI-057-02-02 ANSI/FM 4474(B) 2011 TAS 114(D) 1995 PRI Construction Materials Technologies (TST5878) GWI-060-02-01 ANSI/FM 4474(B) 2011 TAS 114(D) 1995 PRI Construction Materials Technologies (TST5878) GWI-060-02-02 ANSI/FM 4474(D) 2011 TAS 114(J) 1995 GW18001.3 FL14723-R7 Pace 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ESTERN 41 ,.. CREEK Spray Applied Polyurethane Roof Systems TECHNICAL SERVICES, LLC Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) GWI-060-02-03 ANSI/FM 4474(D) 2011 TAS 114(J) 1995 PRI Construction Materials Technologies (TST5878) GWI-060-02-04 ANSI/FM 4474(D) 2011 TAS 114(J) 1995 PRI Construction Materials Technologies (TST5878) GWI-067-02-02 ANSI/FM 4474(B) 2011 TAS 114(D) 1995 PRI Construction Materials Technologies (TST5878) GWI-067-02-02A ANSI/FM 4474(B) 2011 TAS 114(D) 1995 PRI Construction Materials Technologies (TST5878) GWI-075-02-01 TAS 114(D) 1995 PRI Construction Materials Technologies (TST5878) GWI-076-02-02 ANSI/FM4474(D) 2011 TAS 114(J) 1995 UL1897 2012 PRI Construction Materials Technologies (TST5878) GWI-076-02-01 ANSI/FM 4474(B) 2011 TAS 114(D) 1995 UL LLC (TST9628) R5663 UL790 2004 LIMITATIONS 1. Fire classification is not within the scope of this evaluation. 2. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3. Foam plastic insulation shall be installed in accordance with the FBC Section 2603.3, 2603.4 and 2603.6. 4. Spray polyurethane foam shall not be applied when ambient temperature is within 5 degrees of the dew point. Ambient humidity applications limits shall be as listed in Table 1 below. In the HVHZ, the contractor shall monitor and record environmental conditions in the Job Log in compliance with RAS 109. Job Log shall be maintained at the job site and accessible to The Building Official. 5. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to ANSI/SPRI ES-1 (non-HVHZ only) or Roofing Application Standard RAS 111 and the wind load requirements of Chapter 16. 6. In the HVHZ, fastener spacing for base sheets or membrane attachment shall meet the minimum fastener resistance value and the MDP for the specified assembly. It is permissible for a qualified professional to submit a revised fastener spacing utilizing the withdrawal resistance value obtained from TAS 105 testing and calculations performed in accordance with RAS 117 and/or RAS 137, when the fastener resistance is found less than required. 7. For assemblies containing mechanical attachment, the allowable uplift pressure for the selected assembly shall meet or exceed the minimum design loads as determined in accordance with the FBC Chapter 16. For perimeter and corner roof zones 2 and 3, the attachment density may be increased by a qualified design professional, as necessary, to meet the design pressure requirements in these areas. In the HVHZ, calculations shall be conducted in compliance with RAS 117 and/or RAS 137. Outside the HVHZ, commonly used standards include RAS 117, FM LPDS 1-29, or ANSI/SPRI WD-1. 8. Reroofing applications shall be examined in accordance with FBC Section 1511 outside of the HVHZ and FBC Section 1521 within the HVHZ. For mechanically fastened systems, a field withdrawal resistance test (TAB 105 in the HVHZ; ANSI/SPRI FX-1 or TAS 105 in the non-HVHZ) shall be conducted by a qualified professional to ensure the fastener meets the minimum design load requirements of the system. For adhered systems, a field uplift resistance test (TAS 124 in the HVHZ; ASTM E 907, FM LPDS 1-52, ANSI/SPRI IA-1, or TAB 124 in the non-HVHZ) shall be conducted to confirm conformance of the existing to the minimum design loads. 9. The MDP for the selected roof system shall meet or exceed the minimum design loads as determined in accordance with the FBC Chapter 16 without augmentation. 10. Flashings and waterproof coverings for expansion joints shall be of compatible materials and according to the sprayed polyurethane foam manufacturer's published literature. 11. Miscellaneous materials such as adhesives, elastomeric caulking compounds, metal, vents and drains shall be a composite part of the roof system and shall be compatible with the foam and coating. 12. Installation of the evaluated products shall comply with this report, the FBC, and the manufacturers published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 13. The minimum roof slope shall be in accordance with the FBC. 14. All products listed in this report shall be manufactured under a quality assurance programs in compliance with Rule 61 G20-3. GW18001.3 FL14723-R7 Pace 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GREET{ TECHNICAL SERVICES, LLC GACO WESTERN Spray Applied Polyurethane Roof Systems Table 1. Ambient Humidity Applications Limits - Air Temp/ Humidity/ Dew Point Guideline 110 f Air Temp 100 o Humidity �rfl �p 90 & Dew Point 80 70 50 40 30 45 67 40.5 50 70 45.5 55 72 50.5 60 75 55.5 0 45 50 55 160 165 70 75 80 85 90 95 100 a 67 70 72 75 78 80 78 75 70 64 58 50 40.5 45.5 50.5 55.5 1 60.5 65.5 70 73.5 77 79.5 82 83 Dew point and relative humidity forgiven dry bulb temperature. GW 18001.3 FL14723-R7 Pace 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT GACO WESTERN Spray Applied Polyurethane Roof Systems The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6t" Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. �.`%,QGZ PRG E IV * No 74021 �'. STATE OF :4/Z CERTIFICATION OF INDEPENDENCE 2019.06.1 !� 5 15:43:29 -04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A — Installation and Nomenclature (4 pages) 2) APPENDIX B —Approved Assemblies (5 pages) GW 18001.3 FL14723-R7 Peas 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GREED TECHNICAL SERVICES, LLC GACO WESTERN Spray Applied Polyurethane Roof Systems APPENDIX A INSTALLATION Note - Refer to the APPROVED AssEmgws section of this report for specific installation details of a selected assembly. Unless otherwise specified in this report the following installation details shall be met for the named products: Use Products Description and Installation GAF GAFGLAS Stratavent ASTM D 4897, Type II perforated base sheet; granule -surfaced on the bottom of Perforated Venting sheet. Min. 2-inch side laps Base Sheet Base Sheet Firestone MB Base ASTM D 4601, Type II base sheet; Min. 3-inch side laps Firestone SIBS Base ASTM D 6163, Type I, Grade S base sheet; Min. 3-inch side laps Firestone SBS Premium Base ASTM D 6163, Type II, Grade S base sheet; Min. 3.5-inch side laps Board Adhesives Firestone I.S.O. Twin Pack Applied in 3/4-inch wide ribbons Firestone All - Purpose Fasteners Min.0.75-inch penetration through the top rib of the steel deck or wood deck Firestone Heavy Duty Fasteners Min.0.75-inch penetration through the top rib of the steel deck or wood deck Fasteners & Firestone Insulation 3-inch diameter; Galvalume steel plate Plates Fastening Plate Firestone 1.7" LWC Base -Ply Fastener Full embedment of shank into substrate Firestone Two Piece Impactact Nail - Full embedment of shank into substrate Georgia-Pacific Min. 1/2-inch thick DensDeck Prime Roof Board USG SECUROCK Gypsum -Fiber Roof Min. 1/2-inch thick Board GacoFlex E-5320 Two component water based epoxy primer composed of Part A and Part B; shall be Primer reduced with 1 pint of water per gallon of primer and roller applied to surface GacoFlex A-4600 Water -borne acrylic roof coating that is brush, roller or spray -applied at a minimum rate of 1 gal/100 ft2 Polyurethane Foam GacoRoofFoam 2733 2733 Uniformly applied over surface to a minimum thickness of 1-inch GacoFlex A-31 Acrylic quick -set elastomeric coating that is brush, roller or spray -applied in three (3) coats at a minimum total rate of 1.5 gal/100 ft GacoFlex 5-10 Silicone elastomeric coating that is brush, roller or spray -applied in one (1) or two (2) coats at a minimum total rate of 2.2 gal/100 fe Silicone solvent -free, single -component, moisture -cured, waterproof elastomeric Coatings GacoFlex 5-20 coating that is brush, roller or spray -applied in one (1) or two (2) coats at a minimum total rate of 1.5 gal/100 ft2 Silicone solvent -free, single -component, moisture -cured, waterproof elastomeric GacoFlex 5.21 coating that is brush, roller or spray -applied in one (1) or two (2) coats at a minimum total rate of 1.5 gal/l 00 ft2 GacoRoof GR-16 Silicone elastomeric coating that is brush, roller or spray -applied in one (1) or two (2) coats at a minimum total rate of 2.0 gal/100 ft2 Min. 300 psi Celcore Slurry coat min. 1/8-inch thick; 1-inch thick EPS board (1 Ibs/ft'); Min. 2-inch thick MF withHOS Rheology Admixture top coat; Celcore PVA curing compound applied at rate of 300 ft2/gal Celcore S-1 Deck is treated by applying a continuous film with a broom prior to placement of the Cellular Lightweight Celcore lightweight concrete Concrete Min. 300 psi Mearicrete Slurrycoat min. 1/8-inch thick; Min. 1-inch thick EPS board (1 Ibs/ft'); Min. 2-inch Min. 300 psi top coat Elastizell GW18001.3 FL14723-R7 Pace 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC GACO WESTERN Spray Applied Polyurethane Roof Systems APPENDIX A Use Products .Description and Installation Cellular Min. 200 psi Cellular Slurry coat min. 1/8-inch thick; Min. 1-inch thick EPS board (1 Ibs/ft ); Min. 2-inch Lightweight Lightweight Concrete top coat Concrete — Slurry coat min. 1/4-inch thick; 1" thick EPS Holey board (1 Ibs/ft'); Min. 2-inch thick Cont'd Concrecel top coat; Min. f. at 28 days as stated in the Approved Assemblies GW 18001.3 FL14723-R7 Pace 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC GACO WESTERN Spray Applied Polyurethane Roof Systems APPENDIX A Insulation/Cover Board Fastening Patterns Description Fastening Pattern �— 4. .4 leper x 8-/. r O board board o 0 0 0 0 O OT- (Max. 2f? contributory area per fastener) 20 per 4-R x 8-lt Q board (1) (�L o Ill (Max. 1.6ft2 contributory area per fastener) w O -BOO O m 20 per 4-it x 8-it v board (2) O O Q O to (Max. 1.6ft2 contributory area per fastener) GW 18001.3 FL14723-R7 peas 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC NOMENCLATURE GACO WESTERN Spray Applied Polyurethane Roof Systems APPENDIX A The following naming conventions are utilized to specify products in the APPROVED ASSEMBLIES section of this report. Refer to the nomenclature below when deciphering the allowable products for use in the selected assembly. Installation requirements shall be as noted in the APPROVED ASSEMBLIES and INSTALLATION section of this report. Name Definition As Tested Information provided to the report user based on the as tested condition of the system One of the follovring: -GacoFlex A-31 Coating -GacoFlex S-10 -GacoFlex S-20 -GacoFlex S-21 -GacoRoof GR-16 Designed by others in accordance with FBC requirements; As Tested deck construction details are described as follows: Concrete Deck Min. f.= 2,500 psi at 28 days. CWF Deck Min. 2.5-inch thick Tectum I cementitious wood fiber panels Where assemblies are used to recover an existing roof, the existing roof shall consist of Recover only one layer of roofing, i.e. recovering a previously recovered roof is not permitted. Recover roofing shall be conducted in compliance with FBC Section 1511 outside of the HVHZ and FBC Section 1521 within the HVHZ. Min. 22 ga, ASTM A 653 G90, Grade 33, Wide Rib Deck (Type W R) conforming to ANSI/SDI-RD1.0 & FBC; 0.5 % Vented for LWIC applications only The following nomenclature is used to further describe the As Tested condition. F<#> <#> 912-24 HWH self -drilling screws or equivalent fastener at each flute used to Deck Detail Steel Deck secure the deck to the structural supports; Min. 0.25-inch penetration G<#> Min. Grade <#> of Steel Deck L<#> Max. span of <#> inches P Min. 5/8-inch diameter puddle welds at each flute used to secure the deck to the structural supports S<#> 1/4 "-14 HWH x7/8" self -drilling screws or equivalent fastener secured <#>-inch o.c. along the panel side laps Min. PS 1-09 plywood sheathing; APA Span -Rated. Fasteners and stress plates shall be attached as follows: Wood Deck The following nomenclature is used to further describe the As Tested condition. T<#> Min. <#>-inch thick plywood L<#> Max. span of <#> inches N<#> Min. 8d ring shank nails spaced <#>-inch o.c. at the field and perimeter LWIC Poured -in -place Cellular Li htwei ht Concrete with encapsulated insulation board MCRF Minimum Characteristic Resistance Force as determined by TAS 105 for the named fastener in the selected assembly MDP Maximum Design Pressure FL14723-R7 4 of This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK ne Roof WESTERN Spray Applied Polyurethane Roof Systems TECHNICAL SERVICES, LLC APPENDIX B APPROVED ASSEMBLIES The following notes shall be observed when using the assembly tables below. 1. Allowable pressures (MDP) were calculated using a 2:1 margin of safety per FBC Section 1504.9. 2. Refer to LIMITATIONS and NOMENCLATURE sections of this evaluation when using the table(s) below. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly. 4. As Tested information for roof deck construction is provided for information only. The addition of the As Tested deck information does not obviate the requirement for rational design of the roof deck and roof deck attachment in accordance with FBC requirements. System Deck Detail Sheet, Roof Board, and/or Lightweight PrinterAnchor Polyurethane Protective MDP Number Concrete Foam Coating (Psi) C-1 Concrete Deck - - GacoRoofFoam 2733 Coatin g -035 Lim.9 -222.5 CWF-1 CWF Deck - - GacoRoofFoam 2733 Coating (Lim. 9; and G-1 Gypsum Deck - - GacoRoofFoam 2733 Coating -222.5 Lim. 9 MB Base or SBS Base attached with 1.7-inch LWC LC-1 Min. 300 psi Mearlcrete LWIC Base -Ply Fasteners spaced 7-inch o.c. in the laps _ GacoRoofFoam 2733 Coating -05 over Concrete Deck and 7-inch o.c. in two (2) equally spaced, staggered (Lim. 7) rows in the field SBS Base attached with 1.7-inch LWC Base -Ply LC-2 Min. 300 psi Elastizell LWIC Fasteners spaced 9-inch o.c. in the laps and 9-inch _ GacoRoofFoam 2733 Coating -45 over Concrete Deck o.c. in two (2) equally spaced, staggered rows in the (Lim. 7) field Min. 380 psi Celcore MF with HIS SBS Base attached with 1.8-inch Two -Piece Impact -52.5 LC-3 Rheology Admixture LWIC Nails spaced 8-inch o.c. in the laps and 8-inch o.c. - GacoRoofFoam 2733 Coating (Lim. 7) over Concrete Deck in two 2 equally spaced, staggered rows in the field Min. 200 psi Cellular Lightweight MB Base or SBS Base attached with 1.7-inch LWC LC-4 Concrete (MCRFa 176 Ibl) Base -Ply Fasteners spaced 7-inch o.c. in the laps _ GacoRoofFoam 2733 Coating -60 over Concrete Deck and 7-inch o.c. in two (2) equally spaced, staggered (Lim. 7) rows in the field Min. 380 psi Celcore MF with HS MB Base or SBS Base attached Wth 1.7-inch LWC LC-5 Rheology Admixture LWIC Base -Ply Fasteners spaced 8-inch o.c. in the laps _ GacoRoofFoam 2733 Coating -60 over Concrete Deck and 8-inch o.c. in two (2) equally spaced, staggered (Lim. 7) rows in the field Min. 360 psi Celcore MF with HS SBS Base attached with 1.8-inch Two -Piece Impact -67 5 LC-6 Rheology Admixture LWIC Nails spaced 7-inch o.c. in the laps and 7-inch o.c. - GacoRoofFoam 2733 Coating (Lim. 7) over Concrete Deck in two 2 equally spaced, staggered rows in the field GW18001.3 FL14723-R7 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. F" CREEK TECHNICAL SERVICES, LLC GACO WESTERN Spray Applied Polyurethane Roof Systems APPENDIX B System Number Deck Detail Anchor Sheet, Roof Board, and/or Lightweight Concrete Primer Polyurethane Foam Protective Coating MDP s1 Min. 300 psi Celcore MF with HS MB Base or SBS Base attached with 1.7-inch LWC LC-7 Rheology Admixture LWIC Base -Ply Fasteners spaced 7-Inch o.c. in the laps _ GacoRoofFoam 2733 Coating -75 over Concrete Deck and 7-inch o.c. in two (2) equally spaced, staggered (Lim. 7) rows in the field LC-8 Min. 770psi Concrecel LWIC 1/2-inch DensDeck Prime secured 6-inch o.c. in _ GacoRoofFoam 2733 Coating -187.5 over Concrete Deck Firestone I.S.O. Twin Pack Insulation Adhesive Lim. 7 Min. 300 psi Mearlcrete LWIC MB Base or SBS Base attached with 1.7-inch LWC LS-1 over Steel Deck; Base -Ply Fasteners spaced 7-inch o.c. in the laps _ GacoRoofFoam 2733 Coating -45 G33, L6, P, S12 and 7-inch o.c. in two (2) equally spaced, staggered (Lim. 7) rows in the field Min. 300 psi Elastizell LWIC SBS Base attached with 1.7-inch LWC Base -Ply LS-2 over Steel Deck; Fasteners spaced 9-inch o.c. in the laps and 9-inch _ GacoRoofFoam 2733 Coating 45 G33, L5, P, S12 o.c. in two (2) equally spaced, staggered rows in the (Lim. 7) field Min. 380 psi Celcore MF with HS SBS Base attached with 1.8-inch Two -Piece Impact LS-3 Rheology Admixture LWIC over Steel Deck; Nails spaced 8-inch o.c. in the laps and 8-inch o.c. - GacoRoofFoam 2733 Coating -52.5 (Lim. 7) G33, L6, P, S18 in two (2) equally spaced, staggered rows in the field Min. 200 psi Cellular Lightweight MB Base or SBS Base attached with 1.7-inch LWC LS-4 Concrete (MCRFz 176 Ibf) Base -Ply Fasteners spaced 7-inch o.c. in the laps _ GacoRoofFoam 2733 Coating -60 over Steel Deck; and 7-inch o.c. in two (2) equally spaced, staggered (Lim. 7) G33, L5, Ff, S12 rows in the field Min. 380 psi Celcore MF with HS MB Base or SBS Base attached with 1.7-inch LWC LS-5 Rheology Admixture LWIC Base -Ply Fasteners spaced 8-inch o.c. in the laps GacoRoofFoam 2733 Coating -60 over Steel Deck; and 8-inch o.c. in two (2) equally spaced, staggered (Lim. 7) G33, L6, P, S18 rows in the field 1/2-inch USG SECUROCK Gypsum -Fiber Roof Min. 460psi Concrecel LWIC Board attached with Firestone All -Purpose -60 LS-6 over Steel Deck; Fasteners and Insulation Fastening Plates at a rate - GacoRoofFoam 2733 Coating (Lim. 7) G33, L6, P, SIB of 16 per 4-Rx8-R boats 1 fastener per 2ft2 Min. 360 psi Celcore MF with HS SBS Base attached with 1.8-inch Two -Piece Impact LS-7 Rheology Admixture LWIC over Steel Deck,' Nails spaced 7-inch o.c. in the laps and 7-inch o.c. - GacoRoofFoam 2733 Coating -67.5 (Lim. 7) G33, L6, P, S18 in two (2) equally spaced, staggered rows in the field Min. 300 psi Celcore MF with HS MB Base or SBS Base attached with 1.7-inch LWC LS-8 Rheology Admixture LWIC Base -Ply Fasteners spaced 7-inch o.c. in the laps GacoRoofFoam 2733 Coating -75 over Steel Deck; and 7-inch o.c. in two (2) equally spaced, staggered (Lim. 7) G33, L6, P, S18 rows in the field Min. 520psi Concrecel LWIC 1/2-inch DensDeck Prime attached with Firestone LS-9 over Steel Deck; Heavy Duty Fasteners and Insulation Fastening _ GacoRoofFoam 2733 Coating -82.5 G33, L6, P, S78 Plates at a rate of 20 per 4-ttx 8-1t board (1) (Lim. 7) 1 fastener Par 1.6fe GW18001.3 FL14723-R7 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC GACO WESTERN Spray Applied Polyurethane Roof Systems APPENDIX B System Deck Detail Anchor Sheet, Roof Board, and/or Lightweight Primer Polyurethane Protective MDP Number Concrete Foam Coating sf Recover RC-1 over existing smooth surface BUR _ - GaooRoofFoam 2733 Coating -135 roof system with (Lim. 9) Concrete Deck Recover RC-2 over existing granule surface SBS _ - GacoRoofFoam 2733 Coating -155 Mod Bit roof system with (Lim. 9) Concrete Deck Recover 220 RC-3 over existing gravel surface BUR roof - - GacoRoofFoam 2733 Coating (Lim. 9) system with Concrete Deck Recover RC-4 over existing sanded surface APP _ - GacoRoofFoam 2733 Coating -430 Mod Bit roof system with Concrete (Lim. 9) Deck Recover RC-5 over existing granule surface APP _ - GacoRoofFoam 2733 Coating -502.5 Mod Bit roof system with Concrete (Lim. 9) Deck Recover RC-6 over existing sanded surface SBS - GacoRoofFoam 2733 Coating -502.5 Mod Bit roof system with Concrete (Lim. 9) Deck Recoverover SBS Base attached with Firestone All -Purpose RS-1 Steel Deck; Fasteners and Insulation Fastening Plates spaced _ GacoRoofFoam 2733 Coating -60 G33, L6, F1, S24 12-inch o.c in the lap and 12-inch o.c. in two (2) (Lim. 7) staggered rows in the field Recover AO RS-2 over existing smooth surface BUR - - GacoRoofFoam 2733 Coating (Lim. 9) roofs stem with Steel Deck Recover RS-3 over existing smooth surface APP _ - GacoRoofFoam 2733 Coating -106.5 Mod Bit roof system with (Lim. 9) Steel Deck Recover -155 RS-4 over existing gravel surface BUR roof - - GacoRoofFoam 2733 Coating (Lim. 9) system with Steel Deck Recover RS-5 over existing smooth surface SBS - GacoRoofFoam 2733 Coating -162.5 Mod Bit roof system with (Lim. 9) Steel Deck GW 18001.3 FL14723-R7 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK LAM filiIIIIIIIIII TECHNICAL SERVICES, LLC GACO WESTERN Spray Applied Polyurethane Roof Systems APPENDIX B System Number Deck Detail Anchor Sheet,.Roof Board, and/or Lightweight Concrete Primer Polyurethane Foam Protective Coating MDP sf Recover RS-6 over existing granule surface APP _ - GacoRoofFoam 2733 Coating-167.5 Mod Bit roof system with (Lim. 9) Sleet Deck Recover RS-7 over existing granule surface SBS - - GacoRoofFoam 2733 Coating -292.5 Mod Bit roof system with (Lim. 9) Steel Deck Any Approved insulation loose -laid followed by SBS Steel Deck; Base attached with Firestone All -Purpose Fasteners -60 S-1 G33, L6, Ff, S24 and Insulation Fastening Plates spaced 12-inch o.c - GacoRoofFoam 2733 Coating (Lim. 7) in the lap and 12-inch o.c. in two (2) staggered rows in the field 1/2-inch Georgia Pacific DensDeck Prime attached Steel Deck; with Firestone All -Purpose Fasteners and Insulation S 2 G33, L6, P, S24 Fastening Plates at a rate of - GacoRoofFoam 2733 Coating (Lim. m. 7) 20 per 4-ftx 8-ft board (2) 1 fastener er 1.6f1z S-3 Steel Deck; G33, L6, P, S24 _ - GacoRoofFoam 2733 Coating-75 Lim. 9 1/2-inch Georgia Pacific DensDeck Prime attached Steel Deck; with Firestone All -Purpose Fasteners and Insulation -97.5 S-4 G33, L6, Ff, S24 Fastening Plates at a rate of - GacoRoofFoam 2733 Coating (Lim. 7) 20 per 4-ft x 8-ft board (2) 1 fastener er 1.6fe S-5 Steel Deck; _ - GacoRoofFoam 2733 Coating -105 G33, L6, Ff, S24 Lim. 9) 1/2-inch DensDeck Prime secured -147.5 (Lim. 9; S-6 Steel Deck 6-inch o.c. in Firestone I.S.O. Twin Pack Insulation - GacoRoofFoam 2733 Coatin 9 HVHZ Adhesive to the top flange of the deck ribs only) -407.5 S-7 L Steel Deck I - - GacoRoofFoam 2733 Coating (HVHZ; only) Firestone MB Base attached with Firestone All- -37.5 W 1 1 Wood Deck; 1 Purpose Fasteners and Insulation Fastening Plates _ GacoRoofFoam 2733 I Coating (Lim. 7; I T19/32, L24 spaced 18-inch o.c in the lap and 18-inch o.c. in two Non- 2 staggered rows in the field HVHZ GW18001.3 FL14723-R7 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC GACO WESTERN Spray Applied Polyurethane Roof Systems APPENDIX B System Deck Detail Anchor Sheet, Roof Board, and/or Lightweight primer Polyurethane Protective MDP Number Concrete Foam Coating s Firestone MB Base attached with Wood Deck; 12 ga. x 1-1/4-inch ring shank roofing nails with 1- - W 2 T79/32, N6, L24 5/8-inch diameter, 32 ga. tin tabs spaced 9-inch o.c - GacoRoofFoam 2733 Coating (Lim. m. 7) in the lap and 9-inch o.c. in three (3) staggered rows in the field Firestone MB Base attached with Firestone All- W 3 Wood Deck; Purpose Fasteners and Insulation Fastening Plates - GacoRoofFoam 2733 Coating -67.5 T19/32, N6, L24 spaced 12-inch o.c in the lap and 12-inch o.c. in two (Lim. 7) 2 staggered rows in the field Firestone SBS Base attached with Firestone All - W-0 Wood Deck; Purpose Fasteners and Insulation Fastening Plates GacoFlex A- GacoRoofFoam 2733 Coating -67.5 T19/32, N6, L24 spaced 12-inch o.c in the lap and 12-inch o.c, in two 4600 (Lim. 7) 2 stag ered rows in the field 1/2-inch Georgia Pacific DensDeck Prime attached Wood Deck; with Firestone All -Purpose Fasteners and Insulation a GacoFlex A- -82.5 W-5 T19/32, N6, L24 Fastening Plates at a rate of 4600 GacoRoofFoam 2733 Coating (Lim. 7) 20 per 4-R x 8-R board (1) 1 fastenerPer1.6W Firestone SBS Premium Base attached with 0.120- Wood Deck; inch x 1-1/4-inch ring shank roofing nails with 1-5/8- -62.5 W 6 T19/32, N6, L24 inch diameter, 32 ga. tin tabs spaced 6-inch o.c in - GacoRoofFoam 2733 Coating (Lim. 7) the lap and 6-inch o.c. in three (3) staggered rows in the field GAF GAFGLAS Stralavent Perforated Venting Base -105 Wood Deck; Sheet attached with 11ga. x 1-1/4-inch ring shank GacoFlex (Lim. 9 W-7 T19/32, N6, L24 nails and 32 ga. x 1-5/8-inch diameter tin caps E-5320 GacoRoofFoam 2733 Coating Non- spaced 7-inch o.c in the lap and 7-inch o.c. in two HVHZ) 2 staggered rows in the field END OF REPORT GW 18001.3 FL14723-R7 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. SCANNED BY St. Lucie County NEMO I etc. Certificate of Authorization #31455 353 Christian Street, Unit#13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY 4LUATION RFPOF Soprema, Inc. Evaluation Report S18010.06.09-1113 1640 rue Haggerty FL2569-R15 Drummondville, Quebec J2C 5P8 Canada Date of Issuance: 06/15/2009 (819) 478-2400 Revision 13: 02/19/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABEUNG: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced uality Assurance documentation chances or provisions of the Code that relate to the product change Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO [ etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 02/19/2019. This does notseme as an electronically signed document CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEW [etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. NNEMOletc. ROOFING COMPONENT EVALUATION: Product Category: Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the 60' Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section prooertv Standard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.1.1, 1507.2.9.2, R905.1.1, Physical Properties ASTM D1970 2015 R905.2.8.2 1507.3.3, R905.3.3 Physical Properties FRSA/TRI April 2012 2012 FRSA/TRI April 2012 (04-12) Physical Properties ASTM D6163 2008 TAS 110 Accelerated Weathering ASTM D4798 2011 Entity Examination tteterence gate ERD (TST6049) Wind Resistance 2778.07.05 07/15/2D05 ERD (TST6049) ASTM D1970 / TAS 110 (QC) S31370.03.10-1-R1 04/07/2010 ERD (TST6049) FRSA/TR104-12(CH) S11150.05.09-R2 10/05/2010 ERD (TST6049) ASTM D1970 (OH) S37210.11.11 11/09/2011 ERD 1TS16049l ASTM D1970 (MS) S372101211 12/01�2011 ERD (TST6049) ASTM D1970 (MS) S40540.02.13-1 02/19/2013 ERD (TST6049) FRSA/TRI 04-12(MS) S43530.02.14-1-R1 02/21/2014 ERD (TST6049) ASTM D1970 (BC) 544870.04.14-2 04/02/2014 ERD (TST6049) ASTM D1970 (QC) 544870.04.14-3 04/02/2014 ERD (TST6049) ASTM D1970 (OH) S44870.04.14-1 04/10/2014 ERD (TST6049) ASTM D1970 (MS) S44870.04.14-4 04/10/2014 ERD (TST6049) ASTM D1970 (OH) S40540.10.14 10/31/2014 ERD (TST6049) Tensile Adhesion / Long Term Aging SOPC-SC7645.02.15 02/13/2015 ERD (TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015 ERD (TST6049) Wind Resistance SOPC-SC14045.05.17-RI 06/07/2017 M-D (CER1592) HVHZComplience 18-0329.03 06/28/2018 ICC-ES (EVL2396) 20151BC Compliance ESR-1524 03/01/2017 NEMO (TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-RI 04/25/2018 NEMO (TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018 PRI(TST5878) ASTM D1970 (MS) SOP-064-02.01 12/03/2013 Soprema, Inc. (PDM3531) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL, LLC (QUA9625) Quality Control Service Confirmation 07/18/2017 4- PRODUCT DESCRIPTION: 4.2 4.2 Product Speedication Plant(s) Description Lastobond TU HT ASTM D1970 and Gulfport, MS self -adhering, non -woven polyester fabric surfaced, FRSA/TRI April 2012 SBS modified bitumen roof underlayment Lastobond Shield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch NEMO ETC, LLC Evaluation Report S18010.06.09-R33 Certificate ofAuMorlcation a32455 0 EDITION (Z017) FSG NON-HVHZ EVALUATION FL2569-R35 Soprema Roof Undedayments Revision 13: 02/19/2019 Page 2 of 8 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 ONEMOletc. Product Specification Plant(s) Description RESISTO SA SMOOTH PLY ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS 40 modified bitumen roof underlayment d S Lastobonhield HT ASTM D 9970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment Lastobond Pro HT-N ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch Lastobond Pro HT-S ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment EnviroShield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment Lastobond 195 ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, sand -surfaced, Wadsworth, OH SBS modified bitumen roof underlayment Lastobond Eaves ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, sand -surfaced, Protection Sheet Wadsworth, OH SBS modified bitumen roof underlayment Lastobond Eco ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, Gulfport, MS SBS modified bitumen roof underlayment Wadsworth, OH Lastobond'Smooth Seal ASTM D3970 Gulfport; MS self -adhering, glass -mat reinforced, film -surfaced, HT Wadsworth, OH SBS modified bitumen roof underlayment RESISTO LB1236 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, ulfpoq NF BSmociifled bitumen -raof-undedaymen Wadsworth, OH PrimeSource Grip -Rite ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, Eave & Valley Protector Gulfport, MS SBS modified bitumen roof underlayment Wadsworth, OH RESISTO LB1244 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, Gulfport, MS SBS modified bitumen roof underlayment Wadsworth, OH Colphene FR GR ASTM D1970 and Gulfport, MS self -adhering, fiberglass reinforced, granule- FRSA/TRI April 2012 I Wadsworth, OH surfaced, SBS modified bitumen roof underlayment 5.1 This is a building code evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. NENIO ETC, LLC Evaluation Report S18010.06.09-R33 certificate ofAuthorizotion u32455 6r" EDITION (2017) FBC NON-HVH2 EVALUATION Revision 33: 0LZ19/2RIS Soprema Roof Undedayments Page 3 of 8 ONEMOjetc. 5.5 Allowable Roof Covers: TABLE 1: Roor COVUR OPTIONS wood or Slate or Asphalt Nail -On Foam -On Composite Metal Composite Underlayment Shingles Tile Tile Shakes & Slate Shingles Lastobond TU HT Yes Yes Yes See 5.5.1 Yes Yes Yes Lastobond Shield / Pro HT-N / Yes No No No Yes Yes RESISTO SA SMOOTH PLY 40 Lastobond Shield HT / Pro HT-5 Yes No No Yes Yes Yes EnviroShield Yes No No Yes Yes Yes Lastobond Eaves Protection Sheet / Yes No No No Yes Yes Lastobond 195 Lastobond ECO / RESISTO LB1236, Yes Grip -Rite Eave & Valley Protector / Yes No No No Yes RESISTO LB1244 • Lastobond-Smooth-Seal HT Yes No .No Yes Yes Yes Colphene FR GR Yes Yes See 55.1 No Yes Yes 5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations. 5.6 Dow TileBond'" ICP Adhesives Polyset® AH460 Allowable Substrates: FL22525 Lastobond TU HT FL6332 Lastobond TU HT or Colphene FR GR I OPTIONS Underlayment _ Primer Substrates Lastobond Shield, Lastobond Pro HT-N, RESISTO SA (Optional) ASTM D41, plywood, OSB, Southern Yellow SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Elastocol Stick, Elastocol Stick Pine (SYP) EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Zero Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip -Rite Eave & Valley Protector, RESISTO L81244 or ASTM D41 structural concrete Lastobond Smooth Seal HT (Optional) ASTM D41 Plywood ASTM D41 structural concrete Colphene FR GR Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Dens Deck Prime; SECUROCK EnviroShield, Lastobond TU HT, Lastobond Eaves Protection (Optional) Elastocol Stick Zero Gypsum -Fiber Roof Board; ASTM D226, Type I or 11 felt; Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Sopra-G; Modified Sopra-G Grip -Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR z Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report 518010.06.09-R13 Certifrrote of Authorizotion#32455 6m EDMON(2017) FBC NON-MMZ EVAWATION FL2569-RSS Soprema Roof Undedayments Revision 13-.02/19/2019 Page 4 of 8 ONEMOletc. 5.6.1 Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. S.6.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment 5.6.3 For installation under mechanically attached prepared roof coverings, insulation or coverboard shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D, Testing Application Standard TAS 114, Appendix 1 or UL1897. 5.6.4 For installations under mechanically attached prepared roof coverings, base sheet shall be attached per minimum codified requirements. For installations under foam -on tile systems (Lastobond TU HT only), base sheet shall be attached in accordance with FRSA/TRI April 2012 (04-12) or Section 5.6.5 herein. 5.6.5 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12) or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure -45.0i) : Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction, Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -laps. #2 Maximum Design Pressure = -67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol Stick Zero Underlayment: Lastobond TU HT or Colphene FIR GR, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -laps. #3 Maximum Design Pressure=-120.0 psf: Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end - laps. Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -laps. NEMO ETC, LLC Evaluation Report S18010.06.09-R13 Certlj7core ofAuthomotlon 832455 6- EDITION (2017) FBC NON-HVMZ EVALUATION FL2569-R15 Soprema Roof Undedayments Revision 13:02/19/2019 Page 5 of 9 ONEMO I etc. 94 Maximum Design Pressure = -150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -laps. #5 Maximum Design Pressure =-60 0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -laps 5.6.5.1 All other direct -deck, adhered Soprema underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. 5.6.5.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table IA. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualifieitdesigr professionahto resistthe elevated -pressure cn'teTia.- Comm�se�ir metRo—cs are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip -Rite Eave & Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation. Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S or EnviroShield shall not be left exposed for longer than 90-days after installation. Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation. NEMO ETC, U.0 Evaluation Report 518010.06.09-R13 Cottlfitote o/Avthorimelon #32455 6TM EwnoN (2p17( FBC NON-HVNZ EVALUATION F1.2569-1111S Soprema Roof Underlayments Revision 13:02/19/2019 Page 6 of 8 ONEMOletc. 5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. UVAMWIONSFOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat Max. 30-tile stack 6:12 Lugged Max. 30-tile stack 5:12 Max.10-tile stack (bottom 2-tile stack shall be inverted, followed by 8 tiles high 6:12 on slope, as shown below) Lastobond TU HT-' Lugged�- 3 Flat Max.10-tile stack 5:12 Colphene FR GR Lugged Max.10-tile stack 6:12 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris priorto application, and prime the substrate with Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER (if applicable). 6.3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip -Rite Eave & Valley Protector, RESISTO 11.131244 or Colphene FR GR: 6.3.1 Non -Tile Applications: Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, and Soprema published requirements. 6.3.2 Tile Applications (Lastobond TU HT or Colphene FR GR only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual for Self -Adhered Membrane, and Soprema published requirements. For mechanically fastened tile roofing over a 2-ply system, consisting of Base Sheet and Self -Adhered Membrane, fastening of the ASTM D226, Type II base sheet shall be in accordance with Soprema requirements, but not less than that the densities set forth in FRSA/TRI April 2012 (04-12), Table 1. For foam -on tile applications, reference is made to Section 5.6.5 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012 (04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 3 herein, and Soprema published requirements for tile staging. NEMO ETC, LLC Evaluation Report S18010.06.09-1113 CenifWte ofAotho,izetion R32455 61e EDITION 12017)F13C NON-HVHZ EVALUATION R25694SS Soprema Roof Underlayments Revision 13: 02/19/2019 Page 7 of 8 As required by the Building Official or Authority Having Jurisdiction in this product. ONEMOjetc. properly evaluate the installation of Contact the noted CIA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. Refer to Section 4 herein for product & production locations having met codified physical properties specifications. UL, LLC— END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report S38010.06.09-R13 Certfflwte of Author&nftn#32a55 rEDITION (2017)FBC NON-HVNZ EVAWATION FL2569-R15 Soprema Roof Undedayments Revision 13: 02/19/2019 Page 8 of 8 SCANNED NEMO I etc. St. Lucie county Certificate of Authorization#32455 n%A 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY 1640 rue Haggerty Drummondville, Qudbec.12C 5158 Canada (819) 478-2400 FL2569-R15 Date of issuance: 06/15/2009 Revision 13: 02/19/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product underthe Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product chance. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DC4 ANE2983 The facsimile seal appearing was authorized by Robert Nleminen, P.E. on 02/19/2019. This does not serve as an electronically signed document CERTIFICATION OF INDEPENDENCE: 1. • NEMO ETC, LLC does not have, nor does It intend to acquire or will it acquire, a financial interest In any company manufacturing or distributing products It evaluates. 2. NEW ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products It evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being Issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO Ietc. nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ONEW10letc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the 6ei Edition (2017) Florida Building Code through testing in accordance with the following Standards.- Compliance -is subject to the Installation -Requirements and Limitations / Conditions of Use set forth herein. 1504.3.1 Wind Resistance FM 4474 2011 2504.3.2 Wind Uplift UL 1897 2012 1507.1.1,1SO7.2.9.2, R905.1.1, Physical Properties ASTM D1970 2015 R905.2.8.2 1507.3.3,R905.3.3 Physical Properties FRSA/TRIApril 2012 2012 FRSA/TRl April 2012 (04-12) Physical Properties ASTM D6263 2008 TAS 110 Accelerated Weathering ASTM D4798 2011 ERD(TST6049) ERD (TST6049) ERD (TST6049) ERD(TSIFi049) ASTM D1970/TAS 110(QC) FRSA/TR104-12(OH) ASTM D1970 (OH) ASTM 131970_(MS) S31370.03.30-1-R1 S11150.05.09-R2 S37210.11.11 S37210.12.11 04/07/2010 10/OS/2010 11/09/2011 12101 2011 ERD(TST6049) ASTM D1970 (MS) S40540.02.13-1 02/19/2013 ERD (TST6049) FRSA/TR104-12(MS) S43530.02.14-1-R1 02/21/2014 ERD (TST6049) ASTM D19701BQ S44870.04.14-2 04/02/2014 ERD (TST6049) ASTM D1970'(QC) S44870.04.14-3 04/02/2014 ERD (TST6049) ASTM D1970 (OH) S44870.04.14-1 04/10/2014 ERD (TST6049) ASTM D1970 (MS) S44870.04.14-4 04/10/2014 ERD (TST6049) ASTM D1970 (OH) S40540.10.14 10/31/2014 ERD (TST6049)'_ Tensile Adhesion / Long Term Aging SOPC-SC7645.02.15 02/13/2015 ERD (TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015 ERD (TST6049) Wind Resistance SOPC-SC34045.05.17-R3 06/07/2017 M-D(CER1592) HVHZ Compliance 18-0329.03 06/28/2018 ICC-ES(EVL2396) 2015IBC Compliance ESR-1524 03/01/2017 NEMO (TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-R1 04/25/2028 NEMO (TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018 FRI(TST5878) ASTM D1970 (MS) SOP-064-02.01 12/03/2013 Soprema, Inc. (PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL, LLC (QUA9625) Quality Control Service Confirmation 07/18/2017 4. PRODUCT DESCRIPTION: 4.1 E, Wa Product Specification, Plants) DE;cr)ptioe LastobondTU HT ASTM D3970and Gulfport MS self -adhering, non woven polyester fabric surfaced, FRSA/TRI April 2012 SBS modified bitumen roof underlayment Lastobond Shield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SRS modified bitumen roof underlayment available in two widths; 36 and 45 inch NEMO ETC, U.0 - Evaluation Report S36030.06.09-1113 Certificate ofAUMOrIMUM N32455 -9- EDMON(2017) FSC NON-HVHZ EVALUATION FLZS69-R1? Soprema Roof Undedaymems Revision 13: 02/29/2019 Page 2 of 8 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 411 4.12 4.13 4.14 4.15 O-NEMOletc. Product specification' Plant(s) Description RESISTO SA SMOOTH PLY ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS 40 modified bitumen roof underlayment Lastobond Shield HT ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SOS modified bitumen roof underlayment Lastobond Pro HT-N ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch Lastobond Pro HT-S ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment Enviro5hield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment Lastobond 195 ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, sand -surfaced, Wadsworth, OH SBS modified bitumen roof underlayment Lastobond Eaves ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, sand -surfaced, Protection Sheet Wadsworth, OH SBS modified bitumen roof underlayment Lastobond Eco ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, Gulfport, MS SBS modified bitumen roof underlayment Wadsworth, OH . Lostcbon3mobth Seal ASTNiiD1970 = sGuifpoYt`MS self adt�ering Blass mat;retnforced,'fllm surfaced; "- ._ ad'swarTh; OH, , _Drummondville, <SBS:ino"'dified:bitunien rnof.under ayment' 1 RESISTO LB1236 ASTM D1970 QC self -adhering, glass -mat reinforced, sand -surfaced,- ' Wadsworth,OH PrimeSource Grip -Ride ASTM D2970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, Eave & Valley Protector Gulfport, MS SBS modified bitumen roof underlayment Wadsworth,OH RESISTO LB1244 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, Gulfport, MS SBS modified bitumen roof underlayment Wadsworth, OH Colphene FR GR ASTM D1970 and Gulfport, MS self -adhering, fiberglass reinforced, granule- FRSA/TRI April 2012 Wadsworth, OH surfaced, SBS modified bitumen roof underlayment 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the vesigner of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 soprema Roof Underlayments may be used with any prepared roof coverwhere the product is specifically referenced within FBC approval documents. If not listed, a request maybe made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. NEMO ETC, LLC Evaluation Report SMU0.06.09-R13 Certificate ofAuthoriration a32455 6- EDITION (20171 FBC NON-HVHZ EVALUA71 ON Revision 13: FL2569-RIS Soprema Roof Undedayments Page 3 of 8 3 ONEMOjetc. 5.5 Allowable Roof Covers: .. Wood Asphalt Nail -On Compositt Slate or Foam -On e Metal Composite Underlayment Shingles F" Tile Tile Shakes& Slate Shingles Lastobond TU HT Yes Yes See Yes Yes Yes Yes Lastobond Shield / Pro HT-N / Yes No No No Yes Yes RESISTO SA SMOOTH PLY 40 Lastobond Shield HT/ Pro HT-S Yes No No Yes Yes Yes EnviroShield Yes No No Yes Yes Yes Lastobond Eaves Protection Sheet / Yes No No No Yes Yes Lastobond 195 Lastobond ECO / RESISTO LB1236, Grip -Rite Eave & Valley Protector / Yes No No No Yes Yes RESISTO L81244 _.E .:..-__. -- ,LastobondSmooth5eal r YsCalphene FR GR Y Yes See 555.1 No Yes Yes 5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations. 5.6 DowTileBond'"I FL22525 Lastobond TU HT ICP Adhesives Polyset® AH-160 I FL6332 , Lastobond TU HT or Colphene FR GR Lastobond Shield, Lastobond Pro HT-N, RESISTO SA - (Optional) ASTM D41, plywood, OSB, Southern Yellow SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Elastocol Stick, Elastocol Stick pine (SYP) EnviroShield, Lastobond TU HT, Lastoband Eaves Protection Zero Sheet, Lastobond 195, Lastobond ECO, RESISTO L81236, Grip -Rite Eave & Valley Protector, RESISTO LB1244 or ASTM D41 structural concrete Lastobond Smooth Seal HT (Optional) ASTM D41 Plywood ASTM D41 structural concrete Colphene FR GR Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Dens Deck Prime; SECUROCK EnviroShield, Lastobond TU HT, Lastobond Eaves Protection (Optional) Elastocol Stick Zero Gypsum -Fiber Roof Board; ASTM D226, Type I or II felt; Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244, Sopra-G; Modified Sopra-G Lastobond Smooth Seal HT or Colphene FR GR I Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval forOvertuming Moment Resistance Performance NEMO ETC, LLC Evaluation Report S38010.06.09-R33 Certificate 0/Authorization 432455 6i" EDmON (2MI) FBC NON-NUNZ EVALUATION FL2569-R35 saprema Roof Undedaymetns Revision 13: 02/19/2019 Page 4 of 8 NNE'Wletc. 5.6.1 Soprema recommends priming with Elastocol Stick or Elastocol 6000 if the final roof cover is not slated for installation within 24 hours. 5.6.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment 5.6.3 For installation under mechanically attached prepared roof coverings, insulation or coverboard shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayrrfent system in accordance with FM 4474, Appendix D, Testing Application Standard TAS 114, Appendix J or UL1897. 5.6.4 For installations under mechanically attached prepared roof coverings, base sheet shall be attached per minimum codified requirements. For installations under foam -on tile systems (Lastobond TU HT only), base sheet shall be attached in accordance with FRSA/TRI April 2012 (04-12) or Section 5.6.5 herein. 5.6.5 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underiayment systems beneath foam -on tile systems, where the underiayment forms part of the load -path. The following wind uplift limitations apply to underiayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12) or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure=-45.0psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER Underlayment Lastobond TU HT or Colphene FR GR self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -laps. #2 Maximum Design Pressure=-67.5 osf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol Stick Zero Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -laps. #3 Maximum Design Pressure = -120.0 1) Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end - laps. Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -laps. NEMO ETC, LLC Evaluation Report S18010.06.09-R13 Certificate oJAuthorlmtion 932455 6- EDMON(2017) FBC NON41M EVALUATION FLB69-B15 Soprema Roof Underlayments Revision 13: 02/19/2019 Page 5 of 8 "NEMOletc. #4 Maximum Design Pressure=-150.0 Dsf: Deck: Min. 15/32-inch APA-rated BC( plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: • Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -laps. #5 Maximum Design Pressure=-60.ODsf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered; thoroughly rolled using hand roller and/or - weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -laps 5.6.5.1 All other direct -deck, adhered Soprema underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of-45 psf. 5.6.5.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density desigrrectby a quaiifiedesign professional o resist he elevated pressure criteria. ommon y use methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked With an asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss_ Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 osure Limitations: Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip -Rite Eave & Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation. Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S or EnviroShield shall not be left exposed for longer than 90-days after installation. Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation. NEMO ETC, LLC Evaluation Report S18010.06.09-R13 Certhcate ofAatharkatlon e32455 6- EDITION (2017) F8C NON -WIC EVALUATION FLZ569-R15 Soprema Roof Underlayments Revision 13: 02/19/2019 Page 6 of 9 NNEMICIlletc. 5.8 Tile Slippage Limitations (TAS 103 Per FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 3: TIUSLIPPAGE UPAITATIONS FOR DIRECT -DECK TILE INSrALLATIONS -.. _, ,,._ Undedayment .,-_. I . ,., . Tile Profile _ . ., Staging Method .,. ...__.. Maximum slope Flat Max. 10-tile stack 6:12 Lugged Max.10-tile stack 5:12 Max.10-tile stack (bottom 2-tile stack shall be inverted, followed by 8 tiles high 6:12 on slope, as shown below) Lastobond TU HT LuggedCPlphene JJ FR GR Flat Max.10-tilestackLugged Max.10 the stack 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER (if applicable). 6.3 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, and Soprema published requirements. 6.3.2 Tile Applications (Lastobond TU HT or Colohene FR GR only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual for Self -Adhered Membrane, and Soprema published requirements. For mechanically fastened tile roofing over a 2-ply system, consisting of Base Sheet and Self -Adhered Membrane, fastening of the ASTM D226, Type II base sheet shall be in accordance with Soprema requirements, but not less than that the densities set forth in FRSA/TRI April 2012 (04-12), Table 1. For foam -on tile applications, reference is made to Section 5.6.5 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012 (04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 3 herein, and Soprema published requirements for tile staging. NEMO ETC, LLC - Evaluation Report 518010.06.09-R13 eertrfwteofauthmhodon#32455 6mEDmON(2017)FBCNON41MEVALUATION FI.256941115 Soprema Roof undedayments Revision 13: 02/19/2019 Page 7 of 8 ONEMOIetc. As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. Refer to Section 4 herein for product & production locations having met codified physical properties specifications. UL, LLC— - END OF EVALUATION REPORT - NEMO ERC, LLC Evaluation Report S18010.0&09-Rill CerHfimte ofAuthor¢utton #32455 a EDITION (2017) FOC 1101114M fZ EVALUATION FL25694US Soprema Roof Undedayments Revision 13:02119/2019 page 8 of 8