Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 -FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR ^ xz Permit Office: ST. LUCIE COUNTY SCANNED City, State, Zip: FT. PIERCE , FL , .0 (o r �5�� C' Permit Number. By Owner: Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1432.0 sqft.) Insulation Area 2f Single family or multiple family Single-family a. Concrete Block- Ext Insul, Exterior R=4.1 1224.00 ft' b. Frame - Wood, Adjacent R=11.0 208.00 ft' 3. Number of units, if multiple family 1 c. NIA R= ft 4. Number of Bedrooms 3 d. NIA R= ft' 5. Is this a worst case? Yes 10. Ceiling Types (1753.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft 6. Conditioned floor area above grade (ft') 1753 b. NIA R= ft' Conditioned floor area below grade (W) 0 c. NIA R= ft' 11. Ducts R ft' 7. Windows(151.4 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 265 a. U-Factor: Sgl, U=0.54 111.36 ft' SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons S. Floor Types (1753.0 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft' b. ,. Conservation features b. N/A R= ft' 'None c. NIA R= ft. 15. Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 51.39 PASS Total Baseline Loads: 53.86 1 hereby certify that the plans and specifications covered by Review of the plans and f%E STAT this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance y i„,�i' with the Florida Energy Code. PREPAR BY: Before construction is completed r 1 DATE: this building will be inspected for compliance with Section 553.908 �� a I hereby certify that this building, as designed, is in compliance Florida Statutes. C0 with the Florida Energy Code. Wf SRC OWNER/AGENT BUILDING OFFICIAL: DATE: `� DATE: ,� Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. = Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (RgWED FOR CODE COMPLIANCE B I LE 0' CIE BO COUNTY ® �®Cc 9/1512019 2:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft' ___ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' _- 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft' — 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft' ___ 0 1 0 5SIab-On-Grade Edge Insulatio LAUDRY t ft 0 36 ft' — 0 1 0 9/15/2019 2:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 _- 0 1 0 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN 11 ft 0 209 ft2 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft2 — 0 1 0 10Slab-On-Grade Edge Insulatio HALL t ft 0 25 ft2 -_ 0 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 — 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 _- 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic (Vented) IAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood 9 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w 1 NE=>W Exterior Concrete Block - Ext IndWASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 2 SW=>E Exterior Concrete Block - Ext In9NWSTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.4 0 3 NW=>S Exterior Concrete Block - Ext InEMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 4 NE=>W Exterior Concrete Block - Ext In9UWSTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 9/15/2019 2:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space Ft In Ft In Are, Frn,finn Ahgor rZmrfp% _ 5 NE=>W Exterior Concrete Block - Ext InsuM. BATH 4.1 7 0 8 0 56.0 ft- 0 0 0.4 0 -6 NE=>W Exterior Concrete Block - Ext IngffDROOM 2 4.1 12 0 8 0 96.0 ft' 0 0 0.4 0 -7 SW=>E Exterior Concrete Block - Ext IndWNING/GRE 4.1 30 0 8 0 240.0 ft' 0 0 0.4 0 8 NW-S Exterior Concrete Block - Ext InQINING/GRE 4.1 20 0 8 0 160.0 ft' 0 0 0.4 0 _ 9 SW=>E Exterior Concrete Block- Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.4 0 10 NE=>W Exterior Concrete Block -Ext lnsul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 11 SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 _ 12 SW=>E Exterior Concrete Block- Ext Insul FOYER 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 13 NE=>W Exterior Concrete Block - Ext InfiffDROOM 3 4.1 13 0 8 0 104.0 ft' 0 0 0.4 0 14 SW=>E Exterior Concrete Block - Ext InfiEDROOM 3 4.1 1 0 8 0 8.0 ft 0 0 0.4 0 15 N=>SW Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft' 0.23 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Insulated FOYER None .39 3 3 6 8 21.7W WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.54 0.25 N 32.4 ft' 1 ft 0 in 1 It 5 in Drapes/blinds Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 0.54 0.25 N 6.9 ft' 1 It 0 in 1 It 5 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.54 0.25 N 16.2 ft' 1 It 0 in 1 It 5 in None None 4 SW=>E 7 Metal Low-E Single Yes 0.54 0.25 N 39.8 T 1 It 0 in 1 It 5 in None None 5 NW=>S 8 Metal Low-E Single Yes 0.55 0.25 N 40.0 ft' 8 ft 0 in 1 it 5 in None None 6 NE=>W 13 Metal Low-E Single Yes 0.54 0.25 N 16.2 ft' 1 It 0 in 1 ft 5 in Drapesiblinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 ft' 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000264 1168.7 64.16 120.66 .0881 5 9/15/2019 2:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 265 fill Attic 55 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermosta)t:: Y Ceiling Fans: Vent ng Jan Mar € [[ ]] Jun [X] Jul [[ ]] [X] Aug r ]] Sep [ ] L a IN [rX,] Dec [ ]Feb Apr May lXl Jun II 11 Jul [[ 11 Aug [ Sep lXl lxl Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (VVEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 9/15/2019 2:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 lbs/sq.ft. ft' ft 0.3 M. BATH Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8lbs/sq.ft. fF ft 0.3 BATH Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 ENTRY Default(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft' ft 0.3 GREAT/DINING Default(8 Ibs/s .ft. ft' ft 0.3 BEDROOM 3 9/15/2019 2:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner: Jurisdiction: w x Design Location: FL, Fort Pierce c� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General - - Acontinuousair barrier shall be installed in the building envelope. - Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceilinglattic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire Rnr nkler cover ninteg And walls or ceilinas a. in aaonlon, inspection of log walls shall be in accordance with the provisions of ICC-400. 9115/2019 2:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1753 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.543 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 34.8 c) Area 7c. 151.4 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 D Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: THE WINDSOR 2 (� City/FL Zip: FT. PIERCE. FL ���15 1 9/15/2019 2:03:37 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 + wrightsoft 317 ST. LUCIE LN.. FT. Project Summary Date: Entire House By: QUICK CALCS, INC.' L 34946 Phone: 772-466-6799 Fatc 772-4668796 Email: OUICKCALCS@AOLCOM Project Information For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 18467 Btuh Ducts 6190 Btuh Central vent (0 cfm) 0 Stuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 He tin Co Area W 1753 175�3 Volume (fta) 14741 14741 Air changeWhour 0.38 0.20 Equiv. AVF (cfm) 93 49 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A'030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actualairflow , Air flow factor Static pressure . Space thermostat Capacity balance point,= 34 OF 8.5 HSPF 34600 Btuh @ 470F 0 1160 cfm 0.047 rn/Btuh 0.50 in H2O Backup: Input = 7 kW, Output"— 23009 Btuh, 100 AFUE Sensible Cooling Equipment Load Sizing Structure 17655 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturers data n Rate/swing multiplier 0.95 Equipment sensible load 25645 Btuh Latent Cooling Equipment Load Sizing Structure 2453 Btuh Ducts 2554 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 5067 Btuh Equipment total load 30652 Btuh Req. total capacity at 0.70 SHR 3.1 ton Cooling Equipment Summary Make Cartier Trade CARRIER AIR CONDITIONING Cond 25HBC536A•030 Coil FX41DN((B,F)037 AHRI ref 7914586 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed t 20n-Apr-1017.19:28 wrightsoft' RlghtSuite® Universal 201717.0.14 RSU08101 Page 1 ...k CalcslDocuments%WYNNE-THE WINDSOR-REVISED.rup Celc = MJ8 Front Door faces: N wrlghtsoft- RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By- 317 ST. LUCIE L.R. FT. PIERCE, FL 34M Phone: 772-46"799 Fax 77246"796 Email: DOICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 Ex;osed wall 153.0 ft 45.0 ft 3 Room height 8.4 ft d 8.0 It heat/cool 4 Room dimensions 1.0 x 280.0 ft 5 Room area 1753.0 ft2 280.0 ft2 Ty Construction U-%elue Or HTM Area Load number (Btul✓ftuF) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A-0acs _ 0.143 ne 4,00 2,55 488. 448 1795 1141 192. 192 769 489 ]Ao1orn - 1:270. ne '3556 „70.43 7 .0 -'247 ,:488 0 0 0 -:0 %clorn ti270 ne 35.56 70.43 16 0 " 581 1151 0, , 0 ' 0 .,1Ac1om �. 1I270 ne '35,56 45.24 18 ', 0 _ - 581 739 0.0 - .0 ,.0 11 tM 13A-0as 0.143 se 4.00 255 64 41 165 105 0 0 - 0 ," _ 0 L--D ,11D0 0.390 se 10.92 11.31 23 23 248 257 0 0 0 0 13A-0ocs - _.. 0.143 sw - 4.00 , _ 255 `437'+ 396 ... 1589 . .'1007 . " , 56 56 = - 224 943 0.770 .;sw '21.56 . '"27.63 _ 41 ... 45 - •893 1140 _ 0 • 0' 0 , .'..0 lq! 13AAccs 0.143 nw 4.00 255 290 217 867 551 112 79 318 202 IL-(C' 1Aotan 1.270 nw 35.56 45.24 33 0 1162 1478 33 0 1162 1478 - 4A5-2�d. 0.770 rnv 21.56 36.90 41 0 880 1505 0 0 0 0 P : 412C-0sw•:.... - . ' 0.091 .- , '' ':.'.255 .• = 1.28 908 _... -.308 . - 784 ,395 - 0 -;, -0 t - " 0 o C 16A-30md 0.032 - 0.90 2.32 1753 1753 1571 4067 , 280 290 251 .i :.: 650 F `. 22Atpl , -.:._ . 0.989 -.- 27.69 ;, '° 0.00 1753 - .153 i4237 _ 0 280. -45 ... : 1246 "_ .:-0 6 c)AED excursion 1360 600 Envelope loss/gain 15694 15M 3970 3561 12 a) Infiltration 2873 810 809 228 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 46D 0 0 Appliances/other 1000 0 Subtotal oines 6 to 13) 118467 17655 1 4779 3789 Less edema[ load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal : 18467 17655 4779 3789 15 Duct loads 34% 53% 6190 9w 34% 530/, 16M 2005 Tomom load 21160 2111w - Airregwred(cfm) 3�000 A9 - wrightsof[- A RightSuite® Universal 2017 17.0.14 RSU08101 ...k Calc$\DocumentslWYMVE-THEWINDSOR-REVISED.mp Calc=MJ8 Front Doorfaces: N 2017-Apr-10 17:19:28 Page 1 wrightsoft2 Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE ILK, FT. PIERCE, FL 34946 Phone: T724666799 Fax 7724666796 Emil: OUICKCALCS@( AOL.COM 1 Room name WIC M. BATH Oft 7.0 ft 3 Rmohei9 height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 It 1.0 x 61.0 It 5 Room area 63.0 ft2 61.0 ft2 Ty Construction U-\slue Or -HTM Area (ft9 Load Area (ft2) Load number I (BtuWftz°F) (etuwft2) or perimeter (ft) (Btuh) ar perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A4ocs 0.143 no 400 2.55 0 0 0 0 56 49 196 125 -:Mclont .1.270 -ne 3556 .70.43 0 0 0- 0 7' "'0. 247 .488 y1Aclom:' -1:270 ne 35.55 . 70.43 0 0 - 0 0 0 0'• 0 -, 0 lXo1&n 1[270. ne -35.55 '45.24' '0 0 ..0: 0 0 0. 0 ... -.0 11 If �_, 13A4= 0.143 se 4.00 Z55 0 0 0 0 0 0 0 . 0 11DO 0,390 se 1092 11.31. 0 0 0 0 0 0 0 0 4y :'..13A4acs-" .0.143 -sw -4.00 - - 255 0 . 0" . -. 0 ` +.0 ': ,. 0 0 0 .,:.0 ILL, C 4ASzom •._ - - 0:770-,sw 21:56 ':27.53 0:. 0 0 .0. - • 0 0. -. '0 _ '`_0 V)1 13A4ocs 0.143 my 4.00 255 0 0 0 0 0 0 0 0 tAclom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 L�fG 4A5-2o nd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P'- :i:.12C-0sw: '... -`0:D91 '. - ,i255 tt- C28 - 10 .0 0 0.. 0 .' 0 A .:.0 C 16A30md 0.032 - 0.90 232 63 63 56 146 61 61 55 142 F- - - 22A4p1 . 0:989 .- 27:69 '. 0.00 63 '0 0 : 0 '.61 7 194 ''. . ' 0 6 c)AM excursion -5 -26 Envelope loss/gain 56 141 692 729 12 a) Infiltration 0 0 126 35 b) RoomwrRilation 0 0 0 0 13 Internal gains: Occupams @ 23D 0 0 0 0 Appliances/other 0 0 Subtotal oms 6 to 13) 56 141 817 764 Less external load 0 0 -0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 141 817 764 15 Duct loads 34% 53% 19 75 34%a 53% 274 404 Total room load 75 216 1091 - 1168 Air required(cfm) 4 9 51 50 -FId- wrightsofi Universal 2017 17. RSU08101 ...kCales\Documnts\WNNE-THEWINDSOR-REVISED.rup CaIc=MJ8 FrontDaor faces: 2017-Apr-10 17:19:28 Page 2 wrightsoft' RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LR, FT. PIERCE, FL 34946 Phone: 7724668799 Fax 772488-6796 Email: OUICKCALCS AOL.COM 1 Room name LAUDRY BEDROOM 2 ed ) Oft 120 ft 3 Room height 8.0 ft heallcool 8.0 It heat/cool 4 Room dimensions - 6.0 x 6.0 ft 15.0 x 12A it 5 Room area 36.0 ft2 180.0 ft2 Ty Construction U-value Or HTM Area (ftj Load Area Load number (BtUIVWF) (BtuNft2) or perimeter (it) (Btuh) or pmmfeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A4ws - 0143 ne 400 Z55 0 - 0. 0 0 96 80 - 319 203 1Aclm ' - .1 270 -ne '3556 -3556 70.43 . 0 0 -0 - .0 ` .. 0 0 .. 0 '.0 .1lticlom - - 1 270 me- . 70.43 0 0.- "'0t0. 16 0 ' S81 115? Jkollcm'- 1.270 .ne 35.56-- 45.24- 0 -0'. 0 - 0' 0 0 0 !.0 11 W -D 13A-0ocs 0.143 se 4.00 Z55 0 0 0 0 0 0- _ 0 0 1100 '13A 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 ms.. ..: ..0.143;sw': '4:000 255-. 0: - .0. 0- ,.0 0', 0-' 0 -c''4A5�2om :. 0.770.aw, . 21.56 : 27:53 0 0 0 0 0 a 0 0 13AA= 0.143 nw 4.00 Z55 0 0 0 0 0 0 0 0 1Aclom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 . -_; 4Afr2cmd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P ,'12C-0sw- .. 0.091 265 1.28 '. 0 .0 0' 0 0 .' 0-. •0 C 16A-30md 0.032 - 0.90 2.32 36 36 32 84 180 180 1.0 418 F.�22A-tpl : .0.989 -. ..27.E ' 0.00 36 0 0 ' 0 180' -: .: 12 : 332 0 6 c)AEE excurslon -3 -60 Emelope loss/gain 32 81 1394 1711 12 a) Infiltration 0 0 216 61 b) Room vertlation 0 0 0 0 13 Intemal gains: Occupants Q 230 0 0 0 0 Appliances/other 0 0 Subtotal Qines 6 to 13) 32 81 1609 1772 Less e#emal load 0 0 0 0 Less transfer 0 0 0 0 Redishibdion 6 14 6 14 14 Subtotal 38 95 1615 1786 15 Duct loads 34% 63% 13 50 34% 53% 541 945 Total room load 51 145 2158 2730 Airrequired(afm) 2 s 101 117 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A& ,-Pp- wrightsoft- 2017-Apr-1017:19:28 RlghtSuiteO Unh arsal 2017 17.0.14 RSU08101 Page 3 ...k Calcsl0ocumentslWYMJE-THE WINDSOR-REVISED.mp Calc = MJ8 Front Doorfaces: N wrightsoft, RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By- 317 ST. LUCIE LN, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fac 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name DINING/GREAT ROOM KITCHEN 2 Exposed wall 50.0 R 11.0 ft 3 Room height 8.9 It heat/cool 8.9 R heaticool 4 Room dimensions 1.0 x 588.0 R 19.0 x 11.0 It 5 Room area 588.0 It2 209.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ftx F) (BtulJft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heal Cool 6 '13AAocs 0.143 ne 4.00 255 0 0 0 0 0: 0 0 0 -1Aclom :' 1.270 no 35.56 ` 70A3 0 0 0 0 0' -0 0 -, .0 '1Actord -, 1.270 ne -- 35.56 ` i 70.43 ,_ 0 0 0 0 0 0 0 �0 '1Ac1om' - .1.270 -ne- -35.56 .. 45.24 0 0 0 0 - .0 0 0 '0 11 VL-D 13A-4ccs 0.143 se 4.00 255 0 0 0 0 0 0 0 0 11DO 0.390 se 1092 11.31 0 0 0 0 0 0 0 0 yy 13A4asi..- '. - "0.143 sw "400 '- 255 267 - - 226 903 -574 _ -,98"' 98. 392 `'249 l--G 4A5.20m 0.770 'sw 21.56 ' 27.53 - 41 - 22, 893 1140 0 0 0 - 0 13A-4ocs 0.143 my 4.00 255 178 137 549 349 0 0 0 0 1Aclom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 `i 4A5-2=d 0.770 nw 21.55 36.90 41 0 880 15D5 0 0 0 0 P , 12C41sw. ., .. 0.091 - - 2.55 1.28. 0 - 0' 0 0 . 116 116 `. 295 '148 C 16A30md 0.032 - 0.90 2.32 sw 588 527 1364 209 209 187 485 'F' . 22A-tpl, 0.989 27.69 . 0.00 - - 5w - '50 • 1365 : 0 209 : 11 305 ' 0 6 c)AED excursion 1004 -64 Envelope loss/gain 5136 5937 1179 818 12 a) filtration 1000 282 220 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 1000 Subtotal Qines 6to 13) 6136 6679 1399 1880 Less a demal load 0 0 0 0 Less transfer ".. 0 0 0 0 Redistribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 15 Duct loads 34% 53% 2058 3541 34% 53% 469 995 Total mom Iwd 8200 10234 1867 2875 Air required(cfm) 386 440 88 124 -T- wrightsofY Right-SulteDTHEWINDS Universal 2017 17.0.14CaI RSW8101 .:.k CalcslDocumenis\WYPAIE-TF{E WINDSOR-FtEVISED.mp .Calc=MJ8 Front Doar faces: 2017-Apr-10 17:19:28 Page 4 wrightsoft Right-M) Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 7724666799 Fax T724666796 Email: OUICKCALCSPAOL.COM 1 Room name BATH HALL 2 Exposed wall. 5.0 ft 0 ft 3 Room height 8.0 ft heart/cool 8.0 It heaVoW 4 Room dimensions 10.0 x 5.0 ft 5.0 x 5.0 ft 5 Room area - 50.0 ft2 25.0 ft2 Ty Construction U-value tF) Or HTM Area Load Area number I (StuNft (6tuMft2) a perimetu (ft) (Btuh) or perimeter (ft) (BLtuh) Heat Cool Gross WPIS Heat Cool Gross WFIS Heat Cool 6 -1344=c - - 0.143-no .4.00 Z55 40 40 160 102 - 0 0 - 0 " 1Aclorn" 1.270 no '35.56 , 70.43 - 0 0 0 . - ,o 0 .0 , 0 0 >"p ,1Ac1om _ - 1.270 ne. 35.56 . 70.43' 0 ' 0 0 _ ' 01, .0 : 0 - 0 ' 0 1Actom 1.270 ne.' 35.56 - 45.24 . 0 0 : 0 A 0 ' 0 -: p '._.. '.0 11 W L--D 13A-0ocs 0.143 as 4.00 255 0 0 0 0 . 0 0 0 0 11D0 0.390 se 1092 11.31 0 0 0 0 0 0 0 0 ... 13A40cis �4A52om ..0:143 sw - ' 400 ,... 2.55 '0 .. 0 , . 0 0 .. -.0 0 . 0 '.. •p `:.. - ': 0.770'svi .. 21.56 :"'27.53 .. 0 -. 0 , - ..0 ' 0 0 . ,`0' O t-, :,0 �f1 13A4ocs 0.143 my 4.00 255 0 0 0 0 0 0 0 0 I--G 1A-clom 1.270 my 35.56 45.24 0 0 0 0 0 0 0 0 ��--:2 <.` 4A5-2and 0.77p nw 21.56 36.90 0 0 0 0 0 0 0 0 P. ±12C-0sw.- - 0.091 ',' - 255 - 1.28 - 0 0 .. 0 0 - 0 .0 C 16A30md . 0.032 - 0.90 232 50 50 45 11E 25 25 .0 22 ...0. 58 F.. 22A-tpl- - 0.989 ..,_ .. 2759 :. -0.00' so 5 : 138 : 0 ..25 0 - .D ._ • '0 6 c)AED e1•xumlon -8 -2 Envelope Imslgain 343 210 22 56 12 a) Infiltration 90 25 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Qc 230 0 0 0 0 Applianceslother p 0 Subtotal nines 6 to 13) 433 236 22 56 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 -22 56 14 Subtotal 439 249 0 0 15 Duet loads 34% 53% 147 132 34% 637. 0 0 Total room load 586 381 0 0 Air required (cfm) 28 16 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -F[I- wrightsoft- 2017-Apr-1017.19:28 ,gyp Right -Suite® Universal 201717.0.14 RSU08101 Page 5 ...I( CalcstDOcOmentsIVINME-THE WINDSOR-REVISED.mp Calc=M.18 Front Door faces: N wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1 Room name FOYER BEDROOM =aedwall 9.0 ft. 14.0 ft 3 9ht 8.0 it heat/cool 8.0 it heatt ool 4 Room dimensions 1.0 x 920 ft 13.0 x 130 it 5 Room area 920 ft2 169.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuhfftx F) (Btulvftg or perimeter (ft) (Btuh) or perimeter (it) (Btuh) Heat Cccl Gross WP/S Heat Cool Gross WPIS Heat Cool 6 13AAccs 0.143 no -400 255 0 0 0 0 104 88 351 223 b 1Aclow - �1Ac1om-. 1.270 'ne 3556 ` 70.43 0 0 0. 0 0 . 0 0 - 0 `1.270'.ne. 3556-_70.43 0 0.' 0 .0 �: 0. ,0 3Actoms - 1.276 no X55 :45.24 ` 0 0 0. •• -0 - 18 0 �581 + 739 11 N/ �D 13A-0ocs 0.143 se 4.00 255 64 41 165 105 0 0 . 0 0 11DO 0.390 se, 1092 11.31 23 23 248 257 0 0 0 0 4y .. I-=C �13AAdcs- .. :0.143 sw ;'. c.400 ':_:.255 < ,'8 . 8 ;-. '.. 32: .. -20 s'• _ 8 '8 •: 32 _. ; ':20 4Aizam o.no ..aw.' 21.56 .27.53 - o 0 a - 0 0 "0' 0 i.0 Y)I 13A-0ocs 0.143 nw 4.06 255 0 0 a 0 0 0 0 0 �LCC 1Ac1M 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2and 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P` ^i r12C-0sw, 0.091 • .= ,,2.55 :. ,1:28 •88 88 224. 113. -. 104 104 ., 265 " . '.. 133 C 16A30md 0.032 - 0.90 2.32 92 92 82 213 169 169 151 392 F -. 22A-tpl ' - 0.989 + - 27.69 . 0.00 - 92 9 - 249 . - 0 - - 169' 14. 388 - 6 c)AFD excursion -25 S2 Envelope loss/gain 1002 6841 11768 1456 12 a) Infihration 162 46 252 71 b) Room ventilation 0 0 D 0 13 Internal gains: Occupants B 230 0 0 0 0 Appliances/other 0 0 Subtotal Qines 6 to 13) 1163 730 2020 1627 Less e#emal load 0 0 0 0 Less transfer 0 0 0 0 Redlstdbution 0 0 0 0 14 Subtotal 1163 730 2020 1527 15 Duct loads 34% 53% 390 U6 34% 53% 677 808 Total room load 1553 1116 2335 Air required (cfm) 73 48 M7 127 1. Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. wrightsoft- - -- 2017-Apr-1017:19:28 AA RlghtSuite® Universal 2017 17.0.14 RSU08101 Page 6 ... k CaICSXDocuments\WYNNE-THEWINDSORREVISED.mp Calc=MJB Front Doorfaces: N �- wrightsoft- Duct System Summary uo a: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN, FT. PIERCE, FL 34946 Phone: 7724666799 Fas 772-466-6796 Ema1; OUICKCALCS@AOLCOM For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest friction rate Actual airflow Total effective length (I -EL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.213 in/100ft 1160 cfm 183 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (In) H x W (In) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 OxO VIFx 19.5 115.0 St1 BEDROOM 2 c 2730 101 117 0.384 7.0 OxO VIFx 15.0 115.0 st1 BEDROOM h 2697 127 100 0:353 6.0 OxO VIFx 26.8 115.0 st1 DININGIGREAT ROOM c 3411 129 147 0.292 7.0 OxO VIFx 36.5 135.0 st2 DININGIGREATROOM-B C 3411 129 147 0.371 7.0 OxO VIFx 19.9 115.0 st1 DININGIGREAT ROOM C 3411 129 147 0.278 7.0 Ox0 VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 OxO VIFx 7.0 95.0 KITCHEN C 2875 88 124 0.366 6.0 OxO VIFx 21.8 115.0 st1 LAUDRY C 145 2 6 0.371 4.0 Ox0 VIFx 19.9 115.0 st1 M. BATH h 1091 51 50 0.282 6.0 OxO VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273- 6.0 Ox0 VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 0.284 6.0 OxO VIFx 40.9 135.0 st2 wic I c 216 4 9 0.292 4.0 OxO VIFx 36.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (Cfm) FIR (fpm) Qn) pn) Material Trunk st2 PeakAVF 612 602 0.273 780 12.0 0 x 0 VinlFlx st1 st1 PeakAVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx F H wrightsofC 2017-Apr-10 17:19:29 RightSuiteO Universal 2017 17.0.14 RSU08101 Page 1 ACCK ...k CaloslDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk tb1 Ox0 1160 1160 0 1 0 0 0 Ox 0 1 MR 2017-Apr-10 17:19:29 Wi19NtSOft°. Right -Suite® Universal 201717.0.14 RSU08101 Page 2 ^"� ...k CoIcsMoeumenta\WYNNE-THE WINDSOR-REVISED.mp Calc = MJ8 Front Door faces: N