HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR //''� Permit Office: ST. LUCIE COUNTY SCANNED City, State, Zip: FT. PIERCE, FL, �i`- -mod-'\ Permit Number. BY Owner Jurisdiction: St. Lucie Count Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) y 1. New construction or existing New (From Plans) 9. Wall Types (1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 3. Number otunits, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1753.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade (ft2) 1753 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(151.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 265 a. U-Factor: Sgl, U=1.04 111.36 ft2 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.285 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1753.0 sqft.) Insulation Area EF: 0.970 a: Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.74 PASS Total Baseline Loads: 53.86 1 hereby certify that the plans and specifications covered by Review of the plans and 4g136 STgl this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance -;;: `; `' �O with the Florida Energy Code. �+ nu,.�P .; ;;:•• PREPA D BY: DATE: :3,=C Before construction is completed this building will be inspected for compliance with Section 553.908 O - t • a I hereby certify that this building, as designed ' mpliance Florida Statutes. !�, 6� with the Florida Energy Cod Op tiV OWNER/A q ��\ BUI NE JFJCI-AL: DATE: �, DA�Q� - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R14002 0(1 ,2).ED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOGG 9/15/2019 1:61 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1753.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade (ft2) 1753 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(151.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 265 a. U-Factor. Sgl, U=1.04 111.36 ft2 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.285 14. Hot water systems 8. Floor Types (1753.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1753.00 1112 b. Conservation features EF: 0.970 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.74 PASS Total Baseline Loads: 53.86 I hereby certify that the plans and specifications covered by Review of the plans and FgtiB STg7. this calculation are in compliance with the Florida Energy specifications covered by this y0 - ; 80 Code. calculation indicates compliance y0` +, 6 with the Florida Energy Code. � o f+ nnr R %• •' . O PREPARED BY: Before construction is completed w C DATE: this building will be inspected for compliance with Section 553.908 r7 Y a I hereby certify that this building, as designed, is in compliance Florida Statutes. 9� with the Florida Energy Code. G'OD we S¢v OWNERIAGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 9/15/2019 1:51 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft- _- 0 1 0 2Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft2 ___ 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft' ____ 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft' _ 0 1 0 5SIab-On-Grade Edge Insulatio LAUDRY 1 ft 0 36 ft' ___ 0 1 0 9/15/2019 1:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft' ____ 0 1 0 7SIab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft' ___ 0 1 0 BSlab-On-Grade Edge Insulatio KITCHEN 11 ft 0 209 ft' 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft' 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft' 0 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft' 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft' ___ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1 B47 ft' 0 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61112 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft' 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft' 0.1 Wood 9 Under Attic (Vented) BATH 30 Blown 50 ft' 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft' 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft' 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>W Exterior Concrete Block - Ext IndtMSTER BE 4.1 16 0 8 0 128.0 ft' 0 0 0.4 0 —2 SW=>E Exterior Concrete Block - Ext InsMASTER BE 4.1 7 0 8 0 56.0 ft' 0 0 0.4 0 3 NW=>S Exterior Concrete Block - Ext InddASTER BE 4.1 14 0 8 0 112.0 ft' 0 0 0.4 0 4 NE=>W Exterior Concrete Block - Ext InddASTER BA 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 9/15/2019 1:51 PM EnergyGauge® USA 6.0.02 (Rev. 1)-FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below SpaceAreaR-A/allip qorr4mrIA5 NE=>W Exterior Concrete Block - Ext InsuM. BATH 4.1 7 0 8 0 56.0 ft' 0 0 0.4 0 -6 NE=>W Exterior Concrete Block - Ext InfiffDROOM 2 4.1 12 0 8 0 96.0 ft' 0 0 0.4 0 7 SW=>E Exterior Concrete Block -Ext In9DWING/GRE 4.1 30 0 8 0 240.0 ft' 0 0 0.4 0 8 NW=>S Exterior Concrete Block - Ext InQINING/GRE 4.1 20 0 8 0 160.0 ft' 0 0 0.4 0 9 SW=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.4 0 10 NE=>W Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 11 SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 12 SW=>E Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 13 NE->W Exterior Concrete Block - Ext In9IEDROOM 3 4.1 13 0 8 0 104.0 ft' 0 0 0.4 0 14 SW=>E Exterior Concrete Block - Ext In931EDROOM 3 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 15 N=>SW Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft' 0.23 0.4 0 DOORS # Orm Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Insulated FOYER None .39 3 3 6 8 21.7 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 1.04 0.29 N 32.4 ft' 1 ft 0 in 1 It 5 in Drapes/blinds Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 1.04 0.29 N 6.9 ft- 1 ft 0 in 1 It 5 in None None 3 NE=>W 6 Metal Low-E Single Yes 1.04 0.29 N 16.2 ft' 1 ft 0 in 1 It 5 in None None 4 SW=>E 7 Metal Low-E Single Yes 1.04 0.29 N 39.8 ft' 1 It 0 in 1 It 5 in None None 5 NW=>S 8 Metal Low-E Single Yes 1.11 0.27 N 40.0 ft' 8 It 0 in 1 ft 5 in None None 6 NE=>W 13 Metal Low-E Single Yes 1.04 0.29 N 16.2 ft' 1 It 0 in 1 ft 5 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft' 806 ft' 26 ft 8 It 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1168.7 64.16 120.66 .0881 5 9/15/2019 1:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft. DUCTS / — Supply — — Return — Air CFM 25 CFM26 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 265 ft' Attic 55 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre,Thermostat: Ceiling Fans: Heating ']Y Jan Feb Mar A Mer[r[ ]] rr[[ ]] Jul[[ Jun r1 ]] ri EE Oct [rX'] Dee r[X�] Vent ing [)Jan l l [ 1 Feb l l X Mar Apr May LXl Jun Jul Aug Sep [X� [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 9/15/2019 1:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS • Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 M. BATH Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8lbs/sq.ft. ft2 ft 0.3 BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2 ft 0.3 ENTRY Default(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft2 ft 0.3 GREAT/DINING Default(8 Ibs/s .ft. ft2 ft 0.3 BEDROOM 3 9/15/2019 1:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner: Jurisdiction: _ Design Location: FL, Fort Pierce c1 COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. • Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ninino and wirino Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. ElectricaVphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids aomuvu, uiayculun ur log walls shall be In accordance wnn the provislons or IGG-4uu. 9/15/2019 1:52 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The tower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1753 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.058 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285 14. Heating system: Capacity 34.8 c) Area 7c. 151.4 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -On -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: _�\� \ Address of New Home: THE WINDSOR UVC Qr City/FL Zip: FT. PIERCE. FL -Z�-` 4 ' 7 Nqt S 9/15/2019 1:51:55 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 - wrightsoft- Project Summary SCANNED Date: Enure House St. Lucie Count v- QUICK CALCS, INC. y 317 ST. LUCIE LPL, FT. PIERCE, Phone: 772-466-6799 Fax 772-466-6796 Email: For. THE WINDS R �T PIERCE, FL SCANNEr `9-i QS1.� �� Z'� 8Y Notes: St. Luc, Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside.db 75 OF Design TO 28 OF Design TD 15 OF Daily range Relative humidity L 50 % Moisture. difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18467 Btuh Structure 17655 Btuh Ducts 6190 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Use manufacturer's data n Rate/swing multiplier EquipmenfsensibIs 0.95 Infiltration load 25645 Btuh Method Simplified Latent Cooling Equipment Load Sizing . Construction quality Average Fireplaces 0 Structure 2453 Btuh Ducts 2554 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolm (none) Area (ft2) 1753 1759 Equipment latent load 5007 Btuh Volume (W) 14741 14741 Air changes/hour 0.38 0.20 Equipment total load 30652 Btuh Equiv. AVF (cfm) 93 49 Req. total capacity at 0.70 SHR 3.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A'030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 34 OF Backup: 8.5 HSPF 34600 Btuh @ 47°F 27 OF 1160 cfm 0.047 cfm/Btuh 0.50. in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE Make Caner Trade CARRIER AIR CONDITIONING Cond 25HBC536A'030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed ACCA + wrightsoft• Ri9htSuite® Universal 201717.0.14 RSU08101 2017•Apr-1017:Page ago I 1 ... k Calcs\Documents\WYMJE-THE WINDSOR-REVISED.rup CaIc=MJ6 Front Doorfacea:-N �+ wrightsofr RighWO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LR, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name Entire House MASTER BEDROOM 2 E)gmed wail 153.0 it 45.0 ft 3 Room height 8.4 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 290.0 It 5 Room area 1763.0 ft' 280.0 W Ty Construction U-value Or HTM Area (ft2) Load Area (ft-) Load number (BtuNftz•F) (Btuwft') or perimeter (ft) (Btuh) or perimeter (it) (Btuh) Heat I Cool Gross WPIS Heat Cool Gross WP/S Heat Cool 6 13A4ccs 0.143 ne .400 255 488 448 1795. 1141 192. 192 769 469 1Aclonn " 1.270 he, . 35.56 70.43 7 0 247. 48B 0 0 -0 ;1Aclonn -' ':1.270 ne ,35.56 > 70.43 16._ 0 " 581 .1151 0 ,0 i 0 0' ',_ '0 tActom� 1.270 ne' 35.56 45.N 16 0-:_ 581 739 0. 0 _ '0. 11 VL-D 13A-0acs 0.143 as 4.00 2.55 64 41 165 105 0 0 0 :`0 0 11DO 0.390 as 1092 11.31 23 23 248 257 0 0 0 0 3 . 13AAocs; . -. .. :0.143 :.sw: .. ,400 •,.,.2.55 437'-: .�;396 _ ...1584 `1007 56 56 :.. 224 -�.• 1':143 G 4A5-2crn .. 0.770 'svi 21.56 -27.63 41 -. 45 893 1140 0 - 0 - A. - 0 13A4acs 0.143 nw 4.00 255 290 217 867 551 112 79 318 202 I--G 1A-cl m 1.270 nw 35.56 45.24 33 0 1162 1478 33 0 1162 1478 ��----GG 4A62omd 0.770 my 21.56 36.90 41 0 880 1505 0 0 0 0 P'-; !-12C-0sw '0.091 _ .... 255- 1i28. 308, -.308. -784 395 -0'" •0 ." .D _: -.'0 C 1 0.032 - 0.90 232 1753 1753 1571 4067 280 280 251 650 22A-tPl . tpl 0.989 . -, 27.69 -- 0.00 ! 1753 " 153 ;4237 0 - 280 45 1246 - .0 6 c)AED exursion 1360 6W Fmelope loss/gain 15594 15385 3970 3561 12 a) 'Nfiftration 2873 810 809 228 b) Room ventilation 0 0 0 0 13 internal gains: _Occupants @ 230 2 460 0 0 Appliances/olher 1000 0 Subtotal (lines 6 to'13) 1807 176M 47M 3789 Less eMemal load 0 0 0 0 Less transfer ' 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18467 17655 4779 3789 15 Duct loads 34% 530/6 6190 9340 34% 53% 1602 2005 Total room load 24657 26995 6380 5794 Air required (cfm) 1 1160 1160 -300 249 .MA wrightsoft RlghtSuite® Universal 201717.0.14 RSU08101 ... Calc=MJB Front Dcorfaces: 2017-Apr-10 17:19:28 Page 1 wrightsoft° Right -A) Worksheet Job: Entire House Date: QUICK CALCS, INC. By- 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCSa@AOLCOM 1 3 4 5 Room name wall R000m Room height Room dimensions Room area WIC Oft heat/cod 8.0 It 7.0 x 9.0 It 63.0 ft- M. BATH 8.0 ft 7.0 k heaticod 1.0 x 61.0 It 61.0 ft° TY Construction number U-value (Btuh[ftx°F) Or HTM (BtUlVft2) Area yt°) or perimeter (ft) Load (Btuh) Area (ft') or pedmeter (ft) Load (Btuh) Heat Cod Gross WP/S Heat Cod Gnus _ WPIS Heat Cod 6 11 13Abocs 1Aclonl. ilAcrn lo- _ 1Ac1am. 13A-0Ccs 0.143 .1270 . :1270 1.270 0.143 ne no ne- _ ne- se 4.00 ,' 3556 -3556 ' 35.56 4.00 255 .70.43 70.43 ' 45:24 255 0 0 0 0 0 0 0 0 0 0 0 0 0 ..0 0 0 _. 0 0 :.- .0 0 56 7� . -0 0 0 49 0. 0 0 0 196 247 0 A 0 125 ;. 488 - .- 0 U 0 yI 1100 _ •4bocs- • 3A 4AS2arim' . 13A-0acs 1Aciom 4A5-2omd .12C-0sw 16Aa0mtl 22A4pl [ 0390 .. .� 0143 :0.770 0.143 1.270 0.770 ''0.091 0.032 6.989 se sihe swe my my nw -_ _ - . '- 1092 < . "4 00 . 21.56 4.00 35.56 21.66 :i 255 0.90 27.69 11.31 --:255 ':'z7.63 255 45.24 36.90 i 1.28 232 •. "0.00 0 -.. . , .0 0. 0 0 0 : 0 63 63 0 :. 0 0 0 0 0 '0 63 0 0 .: ) 0 .. 0 0 0 0 0 56 -0 0 :. , ; O :0 0 0 0 0 146 . 0 0 0 .: . ,0 0 0 0 ' 0 61 61 0 0 .0 0 0 0 0 61 . .7 0 , 0 - '0 0 0 0 - r 0 55 194, 0 �--0 . ,to 0 0 0 - .: 0 142 0 -D VII P -. `v C 'F 6 c)AED excursion g -26 Envelope loss/gain 56 141 692 729 12 a) Infiltration b) Room ventilation 0 0 0 0 126 0 35 0 13 Internal gains: Occupants @ 230 Applianceslother 0 0 0 0 0 p Subtotal pines 6to 13) 56 141 817 764 Less edematload Less transfer Redistribution Subtotal Duct loads 34% 71IM9 0 0 014 14115 75 34% 53% 0 0 274 0 D 404 TCtal roam load Air required(cfm) 75 4 216 9 1091 51 1168 50 AMA -F(i' wrightsofY RightSuiteO Universal 201717.0.14 RSU08101 ... k CalcslDocuments%WYNNE-THEWINDSOR-REVISED.mp Calc=MJB Front Doorfaces: 2017-Apr-10 17:19:28 Page 2 �i wrightsoft° Right„1® Worksheet Job: Entire House Date: QUICK CALCS, INC. ey- 317 ST. LUCIE LK, FT. PIERCE, FL 34946 Phone: 772-46"799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1 Room name LAUDRY BEDROOM ll 0 It 12.0 ft 3 Room heist 9h 8.0 ft heatfcool 8.0 It heatl000l 4 Room dimensions 6.0 x 6.0 It 15.0 x 120 It 5 Room area 36.0 ft' 180.0 ft' Ty Consm ctim U-value Or HTM Area number (Btuldftz°F) (BtUwftj m perimeter (ft) (B�uh) a perimeter (ft) (B ill) Heat Cool Gross WP/S Heat Cool Gross WPIS Heat Cool 6 13A40Cs - 0143 - no 4.00 2.55 0 0 0 0 96 80, 319 203 I, Iom ,`.:: - .1 270 ne :13556 ` . 70.43 :r 0 - 0 0 .0 0 0 0 ,'. .`-0 .1A-dtom -.. - 1 270 ne • -35.56 70.43 .0 - 0 " 0 ' 0 16 0 ` 581 ' .. 4151. 1Aciam . .1.270 . no 35.56 - • 45:24 0 - 0'-. 0 0 0 - 0. 0 • - 11 W -D 13A-0acs 0.143 se 4.00 255 0 0 0 0 0 0 0 ..0 0 11DO '13A-flocs. 0.390 se 10.92 11.31 0 0 0_ 0 0 0 0 0 Vy - - :. ' '0.143 • sw gym: ' 4,00 - 255 0 - 0 0 0 -. 0 ` 0 0 > • '- '0 �C �4A5-2om '` ' 0.770 21.56 27.53 ', 0 0-. 0 0 . 0 -. '0 0 :. :-o 4y�---G 13A4ocs 0.143 nw 4.00 255 0 0 b 0 0 0 0 - 0 1Aclom 1.270 nw 35.66 45.24 0 0 0 0 0 0 0 0 �--G ' 4A5-2oma 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P ; 12C-Nw 0.091 255 ' 1:28 0 .0 0 - 0 =' 0 - ' • 0 . ' 0 '0 C 16A30md 0.032 - .0.90 232 36 36 32 84 180 ISO 161 418 F - " 22/Ftpl : '. 0.989 • - .27.69 0.00 36 0 . - 0 ' - 0 • 180 ...12 - .. 332 S- . 0 6 c)AED emausion 3 -60 Envelope lass/gain 32 81 1394 1711 12 a) intimation 0 0 216 61 b) Room eemilaton 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 - Appliances/other 0 0 Subtotal (lines 6 to 13) 32 81 1609 1772 Less e#snal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 Subtotal 38 95 1615 1786 15 Duct loads 341/6 53% 13 50 34% 53% 541 945 Total room load 51 145 2166 2730 Air required (cfm) 2 6 101 117 � ' -Fp- wrightsofC Right-Sufte@ Universal 201717.0.14 RSU08101 ...k CalcslDocumenlslWYME-THEWINDSOR-REVISED.mp CoIc=MJ8 Front Doorfaces: 2017-Apr-10 17:19:28 Page 3 wrightsoft Right-J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46"796 Email: 1 Room name DINING/GREAT ROOM WCHEN 2 E)q»sed wall 50.0 ft 11.0 it 3 Room height 8.9 ft heat/cool 8.9 ft heaUcool 4 Room dimensions 1.0 x 588.0 It 19.0 x 11.0 ft 5 Room area 588.0 ft2 209.0 ft2 TY Constntction U-value Or KM Area Load Am Lead number (BtUIVft-F) (Btu19ft2) or perimeter (ft) (Muh) or Perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Haal Cool 6 W 134-0ocs - 0.143 ne 4.00 265. 0 0 0 0 ' 0 0 0 0 lAclam i' - 1270-ne 3556 70.43 •- 0 0 -. 0 <. 0". .0,. 0 '0 1Aclom 1.270 ne '. 35.56 : 70.43 , . 0 • 0 0 ,0 - 0 . 0 0 - 0 0 1Aclom - 1.270'ne - `M.56 4524 0 0 0 0 - 0 0 '0 .'. 0 11 W 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 �D 1100 0.390 se 1092 11.31 0 0 0 0 0 0 0 0 W 13A-0ocs _, . 0.143 sw'. ' 400 ;. • , 255 .. 267 .: . 226 • - 903 - -574 98' 98 .. ' 392 .'249. �C �4As2on 0.779 sw 21.56 - 27.53 - 41 _ 22 893 1140 0 01 0 ' `' 0 V)/ 13A4acs 0.143 nw 4.00 255 178 137 549 349 0 0 -0 0 1Aclom 1.270 my 35.56 45.24 0 0 0 0 0 0 0 0 "" 4A5-2=d 0.770 w 21.56 36.90 41 0 880 1605 0 0 0 0 P :12C'-Osw - 0.091 , 2.55 ' 1.28 0 0 ' 0 - 0 - . 116 .116 -. 295 . 148 C 16A-3Omd 0.032 - 0.90 232 588 588 627 1364 209 209 197 485 F' ; 1:.:22. MPl " 0.989 - 27.69 . 0.00 5W ,W 1385 : 0 209 : 11 305 ' 0 6 c)AED=ursion 1004 -64 Envelope lass/gain 5136 5937 1 1179 818 12 a) Infiltration 1000 282 220 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliarnes/other 0 1000 Subtotal dimes 6 to 13) 6136 6679 1399 1880 Less a#errs load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 15 Duct loads 340/n 53% 2058 3541 34% 53% 469 995 Total room load 8200 10234 1867 2975 Alr required (dm) - 396 440 88 124 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed wrightsofY 2017-Apr-1017:19:28 .4CCEA Right-Suite®Universal201717. RSU06191 Page4 ...k Calcs\Oocuments\WYI�-THE WINDSOR4tEVISEO.mD Colo = MJS Front Door faces: N + wrightsoft• Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LPL, FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUICKCALCS AOL.COM 1 Room name BATH HALL 2 Bposed wall 5.0 ft Oft 3 Room height 8.0 ft heaticool 8.0 ft heaticool 4 Room dimensions 10.0 x 5.0 ft 5.0 x 5.0 ft 5 Room area 50.0 W 25.0 ft- Ty Construction 1-1-value Or HTM Area (ft2) Load Area Load number (Btuh/ft-F) (BtUlVft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross. WP/S Heat Cool 6 V 43A-0acs - 0.143 no :.400 265 40 40 160 102 0 0 0 0 --1Ac1am ::. 1:270 ne :,^35.56 70.43 ';. 0 - ..0 - 0. - 0-- 0.. 0 w0 :1Ac1om „. , 1:270 r 35.55 070.43 0 •' 0 0 .0 ' 0 0 s. 0 - 0 '. 0 UAclom = 1.270 .. ne.. 3556 .45.24. 0.. 0 0 - -0. . 0.:. 0'. ' 0 ...0 11 ly' 13A-0ocs 0.143 se 4.00 2.55 0 0 0 -0 0 0 0 .. 0 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 -D 13AA6cs.: :..0143 sw '4.00 '21.56 -,-. 2.55 - '0 0- - > 0 "0' , . 0 : -. 0 0 ...'.. O L-'�a �4lS2am -.: - 0.770 -sw.' ''27.53 ... 0 : 0 .. 0 0 ` 0 0' >.. 0 ' •,0 V(1 , 13AAocs 0.143 my 4.00 255 0 0 0 0 0 .. 0 0 . 0 1Aclom 1.270 my 35.56 45.24 0 0 0 0 0 0 0 0 I�---..GG 4AS-2omd 0.770 nw 21.56 , 36.90 0 0 0 0 0 0 0 0 P. -: ,12C-0sw, 0.091 '.' - l 265 1.28 0 0 0 :0 0. - 10 0 _ �0. C 16A50md 0.032 - 0.90 2.32 50 50 45 116 25 25 22 58 F .. 22A4p1 --0.989 -- - 27.69 0.00 50 5 : 138 .. 0 25 0 D'._ '0 6 c)AEE etxursim -8 -2 Envelope loss/gain 343 210 22 56 12 a) Infiltration 90 25 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 433 235 22 56 Less e#emal load 0 0 0 0 Less transfer 0 0 0A Redistribution 6 14 -22 14 Subtotal 439 249 05 Duct loads 34% 53% 147 132 34% 53% 0Total room load 586 381 0Air required (cfm) 28 16 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -f11- wrightSofY 2017-Apr-1017:19:28 L`A RightSuite® Universal 201717.0.14 RSUD8101 Page 5 ... k CaleslDocumentslWYNNE-THE WINDSOR-REVISED.mp Cale = MJ8 Front Doorfaces: N F�1 wrightsoft, Right4@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Emil: OUICKCALCS@AOLCOM 1F FOYER BEDROOM 3 9.0 ft. 14.0 ft 3 8.0 ft heaticool 8.0 ft heat/cool 4ons 1.0 x 92-0 ft 13.0 x 13.0 ft 5 920 ft. 169.0 ft' Ty Construction U-vatue Or HTM Area ffil Load Area (ft.) Load number (BtuHft-°F) (BtuWft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat _Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A-4ccs 0.143 no 400 255 0 0 0 0 104 88 351 223 tAciam. .,1.270, no' . 3556 70.43 D 0 - , 0. o - 0 0. 0 `-0 1Ac1om.".; : 1.270 : no. 3556 .. 70.43 . D - 0, 0 . '0 < 10, . :0: 0 . . 0 :1Actom `' 1.270 no 35.56 -45.24 " 0 0:: 0 -0 16 - b - 581 ��739 11 13A-0ocs 0.143 se 4.00 255 64 41 165 105 0 0 0 0 11D0 0.390 se 1092 11.31 23 23 248 257 0 0 0 0 y/ � "13A-0ocs^ ''_ , '.0.143 'sw :: -'400 +. 255 : 8 8' -1.. 32. ,. 20 s . 8 8 ,. _ % L--C' 4A5-2om _ = 0:770 .Sw 21.56 .27.53 - 0 0 _ o I 0 -: - 0 :0 a .. _ a V+l 13A4= 0.143 my 4.00 255 0 0 0 0 0 0 0 0 1Ac1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P"' AX-Csw: - 0.091 '.. '2.55 .1,28 '88 88 "'224 113 .104` - •:104... 265` '... 133 C 16A3Ond 0.032 - 0.90 232 92 92 82 213 169 169 151 392 F 22A-tp1 • 0.989 - -' 27.69 - 0.00 - 92 9 - 249 - 0 -169 14 :. ' '388 ::• . '- 0 6 c)AED excursion -25 ry2 Envelops loss/gain 1002 684 1768 1456 12 a) Infiltration 162 46 252 71 b) Roomver47ation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 1163 730 2020 1627 Less ademal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1163 730 2020 1627 15 Duct loads 34% 53% 390 386 34% 53% 6" 808 Total mom load 1553 1116 2697 2335 Air required(cfm) 73 48 127 100 ZtA -r`p- wrightsofY RightSuiteO Universal 201717.0.14 RSU08101 ... k CalcslDocuments\WYMVE-TREWINDSOR-REVISED.mp CaIc=MJ8 Front Doorfaces: 2017-Apr-10 17:19:28 Page 6 -F+ wrightsoft® Duct System Summary Job: Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-46"796 Email: QUICKCALCS@AOL.COM For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply /. return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm 183 ft Supply Branch Detail Table Name Design (Btuh) Htg (Cfm) Clg (Cfm) Design FR Diam (In) H x W (In) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 OxO VIFx 19.5 115.6 st1 BEDROOM 2 C 2730 101 117 0.384 7.0 Ox0 VIFx 15.0 115.0 st1 BEDROOM 3 h 2697 127 100 0.353 6.0 Ox0 VIFx 26.8 115.0 st1 DININGIGREAT ROOM C 3411 129 147 0.292 7.0 OXO VIFx 36.5 135.0 st2 DININGIGREAT ROOM-B C 3411 129 147 0.371 7.0 0x0 VIFx 19.9 115.0 st1 DINING/GREATROOM-C C 3411 129 147 0.278 7.0 Ox0 VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 Ox0 VIFx 7.0 95.0 KITCHEN c 2875 88 124 0.366 6.0 Ox0 VIFx 21.8 115.0 st1 LAUDRY c 145 2 6 0.371 4.0 Ox0 VIFx 19.9 115.0 st1 M. BATH h 1091 51 50 0.282 6.0 OxO VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273 6.0 Ox0 VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 0.284 6.0 OxO VIFx 40.9 135.0 st2 wic c 216 4 9 0.292 4.0 Ox0 VIFX 36.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (cfm) FIR(fpm) (n) (in) Material Trunk st2 Peak AVF 612 602 0.273 780 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx 1� + wrightsoit, RightSuiteNJ Universal 2017 77.0.14 Page 7 RSU08701 2017-Apr-1017:19:29 'A ...k CalmIDocuments%WYM�-THEWINDSOR-REVISED:rup Calc=MJB Front Doorfaces: N Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (n) Stud/Joist Opening (in) Duct Matt Trunk rb1 Ox0 1 1160 1160 0 0 0 0 Ox 0 VIFx t 'Wrl t' 2017-Apr-i017:19:29 9htSOfRightSuiteB Universal 2017 17.0.14 RSU08101 page 2 ACCK...k Calcs\Docum ntslWYNNE-THE WINDSOR-REVISED.mp Calc = MJ8 Front Door faces: N