Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. SCANNED Street: �,% �(` ��^�q_-f C , - _1 Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, ` Permit Number. BY Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1260.00 f12 b. Frame - Wood, Adjacent R=11.0 192.00 fP 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. N/A R= ft' 5. Is this a worst case? Yes 10. Ceiling Types (1446.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft 6. Conditioned floor area above grade (W) 1446 b. N/A R= ft' Conditioned floor area below grade (W) 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(141.3 sgft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 250 a. U-Factor: Sgl, U=1.04 101.25 ft- SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.284 14. Hot water systems 8. Floor Types (1445.5 sgft.) Insulation Area a. Electric Cap: 40 gallonsEF: a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft' b. Conservation features 0.970 b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.098 Total Proposed Modified Loads: 46.31 PASS Total Baseline Loads: 48.06 1 hereby certify that the plans and specifications covered by Review of the plans and STgl� this calculation are in compliance with the Florida Energy specifications covered by this 04gHFs Code. calculation indicates compliance "„ with the Florida Energy Code. !� uru�r •%, ;i'.•;,.•• D PREPAR B Before construction is completed r+ D this building will be inspected for compliance with Section 553.908 y I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGEN BUILDING OFFICIAL: COp WV DATE: !� DATE: s - Compliance requires certification by the air handler unit manufacturer that the air hanAr ehelbsure talifu s G 9 certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). REVIEWED FOR CODE COMPL@ANCE ST. LUCIE COUNTY 9/13/2019 9:39 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Corli'plla"tff 9ft are Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Crass Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.6 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft' ___ 0 1 0 2SIab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft' ___ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 It 0 203.5 ft' ___ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft' ___ 0 1 0 9/13/2019 9:39 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft' _-_ 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 ____ 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 112 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 NE=>SW Exterior Concrete Block - Ext Ins®EDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 2 SW=>NE Exterior Concrete Block- Ext Ins®EDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0 3 NW=>SE Exterior Concrete Block - Ext Ins®EDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 6 NE=>SW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 7 SE=>NW Exterior Concrete Block - Ext Infi&DROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 8 S=>N Exterior Concrete Block - Ext InfilEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 9 SW=>NE Exterior Concrete Block - Ext InGEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 "11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 12 SW=>NE Exterior Concrete Block - Ext InsdIAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 .13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.4 0 _ 14 NW=>SE Exterior Concrete Block - Ext InsUREAT/DINT 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 112 0.23 0.4 0 9/13/2019 9:39 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Omt Door Type Space Storms U-Value Ft Width In Ft eightin Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 1.04 0.29 N 32.9 ft' 1 ft 0 in 1 It 5 in 1.04 0.29 N 6.9 ft' 1 ft 0 in 1 ft 5 in 1.04 0.29 N 24.0 ft' 6 ft 0 in 1 ft 5 in 1.04 0.29 N 37.5 ft' 1 ft 0 in 1 ft 5 in 1.11 0.27 N 40.0 ft' 8 It 0 in 1 ft 5 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft- 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .1233 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type Subtype Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' 9/13/2019 9:39 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS — supply -- — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 250 ft' Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablrre Thermostafrt: Y Fans:Coollng CMar VeDec Jan Feb EE Apreiling IM Jun �X [ l Jul (X� [ ] Aug r ri Sep j [[X]] L J Nov[[X]] nting [ [ MFeb ar [Xj Apr [ May Jun [ Jul [ ]Aug [ Sep lxl Octet [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. Oft' Oft 0.3 BEDROOM Default(8 lbs/sq.ft. ft' it 0.3 WIC Default(8 Ibs/sq.ft. ft' ft 0.3 M. BATH Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(81bslsq.ft. ft' ft 0.3 BATH Default(8 Ibs/sq.ft. ft' it 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 ENTRY Default(8 lbs/sq.ft. ft' It 0.3 LAUNDRY Default 81bsls .ft. ft' ft 0.3 GREAT/DINING 9/13/2019 9:39 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1446 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.060 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. \ Builder Signature: Date: ��\ L \� C) Address of New Home: v `�1\`c� City/FL Zip: FT. PIERCE, FL­�-' 4 9/13/2019 9:39:43 AM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y ' Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY w Design Location: FL, Fort Pierce c=i COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking,or floor framing cavity g insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind rining and wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log walls she be in accordance with the provisions of ICC-400. 9/13/2019 9:40 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 + wrightsoft° Project Summary Entire House QUICK CALCS, INC. SCANNED BY Job: Da St. Lucie County By: For. THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Notes: Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 'OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range Relative humidity L 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Structure 17520 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none s) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Use manufacturers data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 24753 Btuh Method Simplified Latent Cooling Equipment toad. Sizing Construction quality Average . Fireplaces 0 Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh Heatin Area Coolingg (none) (ft') 144b 1446 Equipment latent load 5521 Btuh Volume (ft3) 12511 12511 Air changes/hour 0.45 0.23 Equipment total load 30274 Btuh Equiv. AVF (cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A'030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 32 OF 8.5 HSPF 34600 Btuh @ 47°F 27 0 1160 cfm 0.049 cfm/Btuh 0.50 in H2O Backup: Input = 7 M Output = 23009 Btuh, 100 AFUE Make Carder Trade CARRIER AIR CONDITIONING Cond 25HBC536A'030 Coil FX4DN B,F)037 AHRI ref 79145 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual air flow 1160 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed - wrightsoft e07-Apr-11 09:29:38 RiAND CARLMversa1 .rup Calc=MJB F 01 Page 1 FM ...uick Calcs\DocumeMslTHE GRAND CARLTOPL1448.ruD Cak = MJ9 Fmnt Daot faces; N wrightsoft° Right-M) Worksheet Job: Entire House Date: QUICK CALCS, INC. By- 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phece: 772-46M799 Fax 772-466-6796 Emil: QUICKCALCS@AOLCOM 1 Room name Entire House BEDROOM 156.2 ft 49.0 ft 3 Roomwall height 8.7 ft d 8.0 ft heatfcad 4 Room dimensions 1.0 x 297.0 It 5 Room area 1445.5 ft297.0 ft' Ty Construction U-value Or HTM Area Load Area (ftj Load number (BtuhfftmF) (Btuivfta) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) . Heat Cool Gross WP(S Halt Cool Gnus WPIS. Heat Cool 6 �''AA5-gem' 13A4ocs � -.0143 - n � �4,00 - 255 503 .465 1862 - 1184 - 72 72. 288 `183 0.770 ..h. .. 21.56 "'19.31 '38 -' `0. . " - 815 730 0 - '0''- D ` `+'0 ��l---G 13AAccs 0.143 a 4.00 255 128 83 333 . 212 .' 0 0 0 .: 0 t--D 1Actom 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 11 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W 13A-0ocs 0.143 se 4.00 2.55 34 34 136 86 0 0 .0 0 t-G 13AAws 0.143 s 4.00 265 360 353 1414 899 216 216 865 so 1Aciom 1270 s 3556 34.77 7 7 247 241 0 0 0 0 13A4ocs - .0.143 w - . 4.00 2.55 310 237 949 . 603 "104 .72 288 ASS 1Aclom ' - 1.270 w ; 35 56 - " .55.21 32' 2 , 1140 . • 1770 . -32 '•2 °.: 1140 .' - 1770 " 4A6-tam-;. .0.770 w '21.56 19.31 41: 41= 880 .' 786' 0 '0" P 12C-0sw 0.091 2.55 1.28 192 192 489 246 0 0 0 0 C :;,.'; :16A.30md - '.0.032 =." - 0.90 . 232 1446 :1446 - 1295 '._" 3354 297 . 297 .. 266 .. .:689 F 22A-tDI 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c)AEDexcursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 kdemal gains: Occupants @ 230 6 1380 3 690 Appliancestother 20M 0 Subtotal Pines 6 to 13) 17848 17520 5053 4925 Less edema' load 0 0 0 0 Less transfer 0 0 0 0 R-cr tdb b.n 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Duct loads 32% 49% 5654 8538 32% 49% 1601 2400 Tots( room lead 23503 26056 6653 7325 Air required(cfm) - 1160 1160 328 326 Agt �- wrilghtsoft' Right -Suite@ Unlversal 201717.0.14 RSU08101 ...ulck Celcs%DOcumentstTHE GRAND CARLTON-1446.mp Calc = MJS Front Door faces: 2017-Apr-11 09:29:38 Page 1 wrightsoft- Right-J® Worksheet Job: Entire House Data' QUICK CALCS, INC. By. 317 ST. LUCIE LM, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Emil: DUICKCALCS@AOL.COM 1 Room name WIC KITCHEN 2 E14nsad wall 0 It 0 It 3 Room height - 8.0 ft heaVcaW 8.0 It heallcool 4 Room dimensions 6.0 x 9.0 ft 1.0 x 1720 It 5 Room area 54.0 ft2 172-0 ft' Ty Construction U-value Or HTM Area (ftj Load Area (ft') Load number (BtuhlftmF) (Btuhlft') or perimeter (ft) (BM) or perimeter (ft) (Btuh) Heat Cool Gross WRIS Heat Cool Gross WP/S Heat Cool 6 13PA=--- .. �9AS2om ' 0143 n". - 4.00 -255 0 - 0 " . 0 r- _-0 .. 0 . - 0.0 - `- - ;. - • 0.770 n"- . 21.56 19.31 . 0 -:.. 0 0 .. " .0 4 „0' . . '0 -.. 0 �" -' 0 V 13A-0ocs 0.143 a 4.00 255 0 .0 0 0 0 0 0 . 0 [:- G D IA-clam 1.270 a 35.56 97.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 -W - '.13A4ocs 0.143 - as 4,00 255 0 0 0 0 0 0 t13A-4= 0.143 s 4.00 265 0 0 0 0 0 0 _ 0 0 1Ac1om -" 1.270 s 3556 34.77 0 0 0 0 0 0 0 a --(' 13A4acs .0.143 w 4.00 265 0 0 0 - .0 0 . 0. 0 0 1Ac1am-, . 1.270 - w ..35.56 5521 0 0 0 0 0 0 0 .0 4AS-26m _: .0.770 w - '21.58 • . 19.31 0 -. 0 0 r 0 0 :0 .`, 0 _ '. 0 P, 12C-0sw 0.091 2.55 1.28 0 0 0 0 64 64 163 82 C'; .,_ ;16A30ma':" 0.032.-. -.0.90 2.32 54'.: -54 48 125 '-172 172. --154 F 22A-tpl 0.989 - 27.69 0.00 54 0 0 0 172 0 0 _'.399 0 8 c)AED emurslon -9 -170 Envelope loss/galn 48 117 317 311 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 2000 Subtotal (lines 6 to 13) 48 117 317 2311 Less eMemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 .0 14 Subtotal 48 117 317 2311 15 Duct loads 320A 49% 15 57 32% 491/6 100 1126 Total room load 64 174 1 418 3437 Air required (cfm) 3 e 21 153 A -FW wrightsof - RightSuite(D Universal 201717.0.14 RSU08101 ...uick CaIcs%Documents%THE GRAND CARLTON-1446.rup Celc = MJ8 Fmnl Door faces: 2017-Aprd1 09:29:38 Page 2 F�F wrightsoft• Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46"796 Email: OUICKCALCS aAOL.COM .1 Room name BATH BEDROOM 2 2 Fposed wall 5.0 it 34.2 ft 3 Room height 8.0 It heaViceol 8.0 It heat/cool 4 Room dimensions 9.0 x 5.0 If 1.0 x 203.5 ft 5 Room area 45.0 ft2 203.5 ft2 Ty Constmclion U-value Or HTM Area Load Am number (BtuMle) Wr (BtUFyfl2) or perimeter (ft) (Btuh) or perimete (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 W ^ ,1344acs:? - . ' - 0.143 ,,n 4:00 - Z55 40 40 160 - 102 ,. 128 128; 513 LG- 4AS2am . ..0.770 ' n ' 21.56 19.31 . - 0 1 0 0 -- 0 ..0 . .0 ., 0 ;...'326 - _= 0 W 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 80 56 225 143 �L-GD tAclam 1.270 a 35.56 87.29 0 0 0 0 24 2 B48 2082 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 w .13A4ocs 0.143 se .4.00 265 0 0 0. 0 34 .34 136 86 W 13AAccs 0.143 s 4.00 2.55 0 0 0 0 32 32 128 81 �C 1Aclom 1.270 s 3556 34.77 0 0 0 0 0 0 0 0 >'.13A4ocsr 0.143'w 400. 265 0 0 0 0' -.0 0. ➢- 0 A clorn _. :1:270, w. - 3556--; 55.21 0 0 0-. - -0 0 0;;" 0`.. .. ;0 �4A5-2orn :0.770 vi - 21:56 19.31 •- 0 0 0 .0, 0 0. 0 - '-, 0 P 12C-0sw 0.091 2.55 1.28 0 0 0 0 0 0 0 ., 0 C ; ::1E 30md:... :0.032 . _ . 0.90 232 45 45 - - 40 104 204 - 204 r -182 >. 472 F 22A-tol 0.989 - 27.69 0.00 45 5 138 _ 0 204. 34 946 0 6 c)AED excursion -16 -85 Envelope loss/gain 339 190 2978 3100 12 a) Infiltration 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 1 230 Appliancesrother 0 0 Subtotal (lines 6 to 13) 425 214 3571 3498 Less wdemal load 0 0 0 0 -Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 ]5 Duct loads 32%. 49% 135 104 32-/ 49% 1131 1704 Total room load 660 318 4702 5203 Air required (rim) 28 14 232 232 Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed wrighYsoft• 2017-Apr-11 09:29:38 . A RlghtSuitoO Uniwrsal 201717.0.14 RSU08101 Page 3 ...uick Calcs%DocumentslTHE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N wrightsoft Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone; 772466-6799 Fax 772466-6796 Email: QUICKCALCSQAOL.COM 1 Room name LAUNDRY GREATIDINING 2 Fxglosed wall 6.0 It 47.0 ft 3 Room height 8.0 ft heat/cool 9.8 It heat/cool 4 Room dimensions 7.0 x 6.0 ft 1.0 x 526.0 ft 5 Room area 42.0 W 526.0 IF Ty Construction U-value Or HTM Area Load number (BtuWfti°F) (BtUWft2) or perimeter (ft) (Btuh) oorronpedmeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross WKS Heat Cool 6 IN 13A4ccs•._�' - 0.143 n' 4.00 - 255 0 0 0: .0. . 255 -. 2V �_ 869 4A5.2om ' b.770' n` 21.56 19.31 '0 -0 - 0. 0'.- 38 `• 0 s ` 815 ,-.:552 r `-730 4)1 13AAocs 0.143 a 4.00 255 0 0 0 0 0 - 0 0 0 II--<D' 1Aatan 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W- :13A4ccs 0.143 se 4.00 265 0 0 0 0 0 0 0 0 t13A4ccs 0.143 s 4.00 255 48 48 192 122 0 0 0 0 1Aclon 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 -G 13A4ocs - 0.143 • w 4.00 . 2.55 0 0 0 0 206 165 661 420 7 -c1an" 11270 : w 35.56 .. 55.21 - :0 0 0 . - , 0 . 0 : -0 -. 0 -'0 ^ - 4A5-2an _ _ 0.770 w `-":21.56 - 19.31 0 0 .' 0 - 0' 41 41 ' 8m . -788 P 12C-0sw 0.091 255 1.28 56 55 143 72 0 0 0 _ 0 C .. 16A30mdI-. _0.032 ` :- '0.90 Z32 -42 42 38 ` `97 . .526 526, '':: -'471.1220 F 22A-tpl 0.989 27.69 0.06 42 6 166 0 _ 526 47 1302 0 6 c)AED excursion -22 668 Fm Iope loss/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 643 298 6994 5112 Less ereemal load 000stransfer000Redistribution0 j 0014 Subttal 298 5994 5112 15Ductloads 32% 49% 145 32% 49% 1899 2490 Total room load 846 443 7892 7602 Alr required(cfm) 42 20 390 338 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .AA wrigY2017-Apr-110P hsofY Right -Suite® Universal 201717.0.14 RSU08101 Page ...uick CaIcslDocumemslTHE GRAND CARLTON-144fi.rup Cale = MJ8 Front Door faces: N 9 wrightsoft. Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE U%, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466fi796 Erreil: QUICKCALCS@AOL.COM 1 Room name FOYER M. BATH 2 BWsed wall 7 0 ft 8.0 ft 3 Room height 8.0 It heat/cool &0 If heat/cool 4 Room dimensions 1.0 x 50.0 It 7.0 x 8.0 It 5 Room area 50.0 ft2 56.0 ft2 Ty Conshuction U-value Or HTM Area er Load Am number (Btuhtti F) (Stu'vill or perime (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gnus WKS Heat Cool Gross WP/S Heat Caol 6 d3A ocs .: '4AS2am " " '0.143 n ---.:4.00 -' - 255 . 8 . .8 32 : 20 ` 0 " 0 °,., 0 `'0 L4; 1!*' - - 0.770 -. n 21.56 ' 19.31 - -0 - . -. a 0 - -0 . ` 0 - `o Vy 13A4ccs 0.143 a 4.00 255 48 27 108 69 , 0 ' o- o IL�D, 1Ac1an 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W .13A4ccs 0.143 se . 4.00 265 0 0 0 0 0 0 0 0 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 64 57 228 145 1Ac1cm 1270 s 35.56 34.77 0 0 0 0 7 7 247 241 ' 13A-0ocs 0143 " w - 4.00 255 0 0 0 0 0 0 0 • 0 1Aclom ,. . 1270 ',w.. 35.56 , 55.21 - 0. 0 0 . 0 . -o 10 •.:..... 0 ;>0 4A5-2oir0-- - 0 770 . W, z1.5s : 1s 31 0'- o _ a o . o - a o . o P 12C-0sw 0.091 2.55 1.28 72 72 183 92 0 0 0 0 C,.: .. _ :16A-30mtl - -. 0.032' - 0.90 - 1232 . ..50 ..50 45 . 116 . '66 - ,.56 ..-50 . A30 F 22A401 0.989 - 27.69 0.00 50 7 194 0 56 8 222 0 6 c)AED emursionry Sy -W Brvelope[oss/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Roomventlation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 913 529 885 516 Less edema[ load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal . 913 529 885 15 Duct loads 32% 49% 289 258 32% 49% 280 251 251 Total mnom load 1202 787 1166 768 Air required (cm) 59 35 58 34 Calculations approved byACCA to meet all requirements of Manual J 8th Ed Aft' wrightsoft- 2017-Apr-1109:29:38 , Right-Sufte® Universal 2017 17.0.14 RSU08101 Page 5 ...uick CalcslDocumentslTHE GRAND CARLTON.1446.mp Cale = MJB Front poor faces: N Duct System Summary Job: wrightsofty rY Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:-772-466-6799 Fax 772466-6796 Email: OUICKCALCS@AOLCOM el-roject Intormation For. THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Heating. Cooling Extemal static pressure 0.50 in H2O 0.50 in H2O Pressurelosses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.250 / 0.250 in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.285 in/100ft 0.285 in/100ft Actual airflow 1160 cfm 1160 cfm Total effective length (TEL) 176 ft Name Design (Btuh) Htg (Cfm) Clg (cfm) Design FR Diam (In) H x W (In) Duct Matl 'Actual Ln A Ftg.Egv Ln (ft) Trunk aATH h 560 28 14 0.364 4.0 OxO VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0.360 7.0 0x0 VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 0x0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 0x0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 0x0 VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 0x0 VIFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 0x0 VIFx 31.8 135.0 st2 'KITCHEN c 3437 21 153 0.379 6.0 OxO VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 OxO VIFx 23.3 115.0 st1 M. BAM I -A h - 768 58 34 0 0 OxO VIFx 0 0 wic c 174 3 8 1 0.309 4.0 Ox0 VIFx 1 27.0 1 135.0 1 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (In) Material Trunk st2 Peak AVF 721 672 0.285 918 120 0 x 0 VinlFlx st1 sti PeakAVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx Ata wri htsoft' �� � 9 RightSuSeO Universal 2017 17.0.14 RSU06101 2017-Apr-1109.29.38 Page 1 -... ulck CalcMDocunents\THE GRAND CARLTON-1446.mp Cale =MJS Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W I (n) Stud/Joist Opening (in) Duct Matl Trunk rb1 OxO 1160 1160 0 1 0 0 0 Ox 0 VIFx 2017-Apr-11 09:29:38 wrightsoft• RightSuite® Universal 201717.0.14 RSU08101 Page 2 ...uick Calos1Documents\THE GRAND CARLTON.1446.mp Calc = MJ8 Fmnt Doorfaces: N