Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT j SCANNED Street: THE STERLING Permit Office: ST. LUCIE COUNTY BY City, State, Zip: FT. PIERCJE, FL, Permit Number: St. Lucie County Owner: `\ Jurisdiction: - -" Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft= 4. Number of Bedrooms 2 d. N/A R= ft' 10. Ceiling Types (1474.0 sqft.) Insulation Area 5. Is this a worst rase? Yes a. Under Attic (Vented) R=30.0 1474.00 ftz 6. Conditioned floor area above grade (ft� 1474 b. N/A R= ft' Conditioned floor area below grade (ft') 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 275 a. U-Factor: Sgl, U=1.04 101.25 ft' SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.11 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor. N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.284 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1473.5 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft' b. Conservation features b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 47.03 PASS Total Baseline Loads: 48.47 1 hereby certify that the plans and specifications covered by Review of the plans and 4gtiE Sr9j this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. mr,., "••..; PREPARED BY: Before construction is completed r O DATE: ---- IMF 1� this building will be inspected for compliance with Section 553.908 0 „ I hereby certify that this building, as designed, is in compliance Florida Statutes. !,), with the Florida Energy Code. Co We i¢J OWNER/AGENT: BUILDING OFFICIAL: DATE: `�� DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosur a ifres Is certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY 9/11/2019 12:29 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Cord' are Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE STERLING IMP Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlalBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft' — 0 1 0 2Slab-On-Grade Edge Insulatio WIC t ft 0 63 ft' 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 fP -- 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN t ft 0 192 ft' — 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' -_ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' -- 0 1 0 7SIab-On-Grade Edge Insulatio ENTRY 7 ft 0 55 ft' -- 0 1 0 9/11/2019 12:29 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT' FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 0 1 0 9Slab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft2 246 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 NE=>SW Exterior Concrete Block - Ext Ins®EDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 2 SW=>NE Exterior Concrete Block - Ext InsiBEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0 3 NW=>SE Exterior Concrete Block - Ext Ins®EDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 6 NE=>SW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 7 SE=>NW Exterior Concrete Block - Ext InfiEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 8 S=>N Exterior Concrete Block - Ext InBEDR00M 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 9 SW=>NE Exterior Concrete Block - Ext InfiffDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 10 SE=>NW Exterior Concrete Block -Ext lnsulENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 12 SW=>NE Exterior Concrete Block - Ext InsdIAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 13 NE=>SW Exterior Concrete Block- Ext InsGREAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.4 0 14 NW=>SE Exterior Concrete Block- Ext Ins REAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.4 0 9/11/2019 12:29 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 1.04 0.29 N 32.9 ft° 1 ft 0 in 1 ft 5 in 1.04 0.29 N 6.9 ft- 1 ft -0 in 1 ft 5 in 1.04 0.29 N 24.0 ft- 6 ft 0 in 1 ft 5 in 1.04 0.29 N 37.6 ft' 1 ft 0 in 1 ft 5 in 1.11 0.27 N 40.0 ft' 8 ft 0 in 1 ft 5 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000366 1375.7 75.53 142.04 .1233 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' 9/11/2019 12:29 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS _ / --Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 276 ft' Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabl[e Ceiling Fans: ]Thermostar[t:']Y Heat ng EX] Jan Feb [[ ,� IXl Mar M:yX] Jun 4 ] Jul D� [ ] Aug [X] [ ] Sep [ ] L.1 Ll Dec [[X]] Venting 111 Jan I I Feb l l IIX1l Mar Apr [ ] May LXi Jun [)Jul [ ]Aug [)Sep Q� Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 lbs/sq.ft. ft' ft 0.3 M. BATH Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 ENTRY Default(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY Default(8 Ibs/s .ft. ft' ft 0.3 GREAT/DINING 9/11/2019 12:29 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: Jurisdiction: Design Location: FL, Fort Pierce O COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking,or floor framing cavity g ty insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall ag.nd behind pining and wiring- Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box of The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids "• ••• _"_••. I-•oV--' v, ,ve ..nna a,mu uc n, a IUw 11g w1O1 me PIUVI5wn5 Or Ri IJIJ. 9/11/2019 12:29 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1474 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.060 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. ,\ Builder Signature: /� Date: Address of New Home: _THE STERLING `, �� r^ �r 't City/FL Zip: FT. PIERCE, FL S �8 9/11/2019 12:29:23 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 wirightsoftProject Summary o, Entire House By. QUICK CALLS, INC. For. WYNNEDEVELOPMENT' SCANNED THE STERLING, FT. PIERCE, FL \\ BY Notes. St. Lucie County Design Information Weather Fort Pierce, FL, US Winter Design Conditions. Outside db Inside db Design TD Summer Design Conditions 42 OF Outside db 70 .OF Inside db.. 28 OF Design TO Daily range Relative humidity Moisture difference Heating Summary Structure 18188 Btuh 5650 Central vent (0 dm) Btuh (none) Humidification 0 Biuh Piping 0 Btuh Equipment load 23842 Btuh Infiltration Method Construction quality Fireplaces Simplified Average He1474 Co Area 1474 Volume)(ft? 12227 12227 Atrchan esibour 0.45 0.23 Equiv. EquiA{chrt) 92 47 Heating Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536A•030 AHRI ref 7914585 8.5 HSPF 34600 . Btuh @ 47°F -27 OF 1160 cfin 0.049 cfrnf tuh 0.50 in H2O = 33 OF Backup: Input=7 kW,Output= 23009 Btuh,100 AFUE 90 OF 76 OF 15 OF L 50 % 61 grub Sensible Cooling Equipment Load Sizing Structure 17877 Btuh Ducts Central vent (0 dm) $�0 Btuh (none) Blower 0 Btuh Use manufacturers data n Rate/swing multiplier Equipmentsensible load 0.95 25093 Btuh Latent Cooling Equipment Load Sizing Structure 2958 Btuh 2310 Central vent (0 cfm) Btuh (none): Equipment latent load 5277 BhJh Equipment Total Load (Sen+Lat) 30370 Btuh Req. total capacity at 0.70 SHR 3.0 ton Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Cond 25HBC536A'030 Coil FX4DN F)037 AHRI ref 791458 Efficiency 12.0 EER,15 SEER Sensiblecooling 24360 Btuh Lateritcooling 10440 Btuh Total cooling 34600 Btuh Actual 1160 cfrn _airtlow Airflowfactor 0.044 cfmlBtuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 4.V r!etSM!^ 2019Seµ1709:31.10 m, ww-r� v+ Pogo-Site®Uiwrsal201919.0A7RSW8101 'Page1 .xcmeftWdglisoBFNAQWYNNE•TFE STERLNGnp Calc=MI8 FrortOoorfacavN - wrightsoft Right-.10 Worksheet Job: Entire House Data: QUICK CALCS, INC. By,. 317 ST. LUCIE M FT. PIERCE. R. 34946 Phom:772-466-6799 Far772-466-6796 Emil: GUICKCALCS@AOLOOM I Roomnanne Entire House MkSTER BEDROOM 2 EVosecll 1562 It Szo It 3 Room height 8.3 it d 8.0 ft heatbool 4 Rcorricrinneftow 1D x 329.0 It 5 Rwnn arm 1473.5 ftF 329.0 f? Ty Construction U-value Or HTM Area (fV) Load kea Ill) Load number (Btu=�F) (fthffl or penmetar (fl) (Btuh) a pen . meter (f) (Ehuh) Heat I Cool Gross NfS Heat Cool Gross I NIPS Heat Cool 6 -w,. "0.143 - n& .4.00 2.55 479 .2 1124 80 .80 -ne 35.56 • -70A3 38 .o I -n lArCIOM 1270 se 35.56 34.77 24 24 we 829 a 0 0 0 11 1100 0.390 se 10.92 1131 224 22 236 a 0 "A00'265 "L -- 34- '138 -244 • 1-66 o '0 0 ?0I -0 0 WIaAA. 1A-vorn Q143 w 4.00 2.55 360 353 1414 899 MAI 224 897 575L— 1270 w 35.56 4291 7 5 247 298 0 0 0 0 -0143 to 4b0 !zSS '290 -217 867 -551 "112 35.56 4524 _33 1 7 4 8 33: ?:01162 AA5-2d*�.' �'_A770 RN 21.56 --�V.54 'Al - 0 .:1880 24 f 0 0 6, P, 12C-0w 0.091 255 128 192 192 489 246 0 a 0 0 164130rT '0-032 2.32 474- 474 -1320 3419 329,''i- 329 295 F 0.989 27.69 0.00 1474 156 0 329 52 1440 0 .4325, • j' o 7. ? L 6 C) AED QCurslon 784 1 1 680, Enwelol*loss/galn 15366 113954 4432 3897 12 a) Infilration 2822 M 909 249 b) Rwmvenflaffon 0 0 0 0 13 Immalgains: 0—panls@ 230 6 1150 2 460 Appliances6other 2000 0 Subt3WQms61o13) 18188 117877 5341 4608 a] load 0 0 0 0 Lesstransfer 0 0 01 01 Redshibuffm 0 0 0 0 14 Subblal 18188 17877 5341 4606 15 DuctIcqds 31%1 48%.1 56541 8536 1660 2199 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. WrIpli 201"ep-170931:11 rw 201919.0.07RSLIOBIOI Pagel on rbkWdghtsoftWADWYNNE-THESTERLINGAp Calc=MJS FrorfDoorfaces:N I wrightsoit- Right-JO Worksheet Job., Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE I.M. Fr. PIERCE. FL34946 Phvrn:772-466-679917ax772-4666796 Email QUICKCALCS0AOL.COM I Rooms WIC M RATH 2 EVoseclYdI Oft 5.0 ft 3 ROOM helight 8.0 It heaftol 8D it hwV=l 4 Room crimmsiorm 7.0 x 9.0 ft 7.0 x 8.0 ft 5 Roonnarea 63.0 IF 56.0 IF Ty Con*ucdon U-value Or HTM Area Load Am Load number I (BtuhAfL'F) (Bb1h1M . or pen eter (I (ft ah) peri (t (Bluh) H;; Cool GFOM NAPIS Heat Cool Gross WIS Heat Coof 6 'tt, M -- 1". 1. . -0.143 .',9' 0 - " ;ISO � . I �O i Aclow -1270 35M 76A3 1:1 0 .0 -.,o - -0 01 w 13A-4= 0.143 w 4.00 255 0 0 0 0 0 L:G IA-clorn 1270 w 35.58 34.77 0 0 0 0 0 D 11DO 0290 w 10.92 1131 0 0 0 0 0 ,w � -I;- 13A 1 ;� '0--,- —0, 0 0 �;. - 0 WL—G 13AA= IA-clorn 0.143 w 4.00 2M 0 0 0 0 64 f 1270 w 35.56 4Z91 0 0 0 0 '043- --74.00-;_T•25W 't 'a 0 1270 56 4524 .a o D.77MMI!,',21.56 0 0- �,o 'X p 12C-Ow 0.091 2.65 1.28 0 0 0 0 c C1 6900101. �ft[).032 �232 63 56 146 Se F a.989 0 0 6- 7 61 C)AED� . m 1 1 -21 1 1 1 225 EnWopeloWgain 1 561 1451 1 1 7471 798 12 a) Infilbafion 01 —01 1 1401 38 b) Room%eryfilaffon 0 0 0 0 13 Inbffnal gaim O=pants@ 230 0 1 1 01 01 1 1 0 Lme"em"'Oa' Lmtransfer Redishibulion 14 1 SUI)bw 15 Dudimcis Calculations approved bvACCA to meet all reaulrements of Manual J 8th Ed -plh- wr An 2019-SeIO709:31:11 A& Rgtt-StiteOUi�rwl2Ol9l9.0.07RSLI08101 Paget —0arn nMWdghMtWACWYNNE-THESTERLINGsto Calc=MJ8 From Doorfaws:N wrightsoft Right-JO Worksheet Job: Entire House Data: QUICK CALM, INC. BY. 317 ST. LUCIE LN, FF. PIERCE, FL 34948 Phow: 772-466-6799Fa 772-466-6796 E=]]:QUICKCALCS@AOL.COM 1 Rwmwrw IQTCHEN BATH 2 EVOSedYdl 0 It 5.0 It 3 Roomheight 8.0 It hmvmt 8.0 It heaftol 4 Room dowslom 1.0 x 1920 It 9.0 x 5.0 It 5 Roornzirm 192.0 IF 45.0 R' Ty Construction U-value Or HTM Arm (f* Load Area (W) Load number (BWhdL'F) (BWIVR� or pedrneiir (11) —Gri:w (Btuh) a Wmebar M (BUh) Heat Cod Grow NFro Heat Cool Gros NIP/S Heat Cool 6 -G 1-3A46ES- 'JA -om ne •2'55 0 0 -'40 40 "--,160 -,,102 V'35.56 -'70A3 0 0 :0 i0 0 "-��;o '0 ;'0 %J�j 13A-4= O.W w 4.00 2,55 0 0 a 0 0 0 0 0 IA-clorn 1270 in 35.56 34.77 0 0 0 0 0 0 0 0 1 1100 D3M w 10.92 11.31 0 0 0 0 0 0 0 0 71' '6' 43 A " i �' -�-400 '2.55 0 7-0 0.", 0 '0 w L—G 13A-4cm IA-d 0.143 &�' '-4.06 -0 0 0 0 0 0 0 0 om 1270 0143 w "Mi 35.56 _4.00 :35.56 42.91 �-'7.J:2M 4524 0 -�'70 , o 0 0 "o 0 -0 0 0 "o 0 0 0 0 O .!..' � 0 0 41 0 0 -0 0 .0. 21M 27.54 -0,• �70 0 o' , p 12C-ow 0.091 255 128 64 64 163 82 0 0 0 0 0.632 0.9 D . T232 ,',192 .192 :-172 445..-' AS ::. 45 104 F 224-fpl� 0.989 0.66 0.00 192 0 0 0 46 5 138 0 701 'Y 6 c)AEDwairsim -27 -2 Ewelope lossIgain 335 501 339 2064 12 a) brillimban 0 0 97 24 b) Rwrriwintlaton 0 0 0 0 13 Inb=d gains 0-4—t@ 230 0 0 0 0 Appliwomilciftr 2000 0 Subt)Woinw61o13) 335 2501 426 22S LMe"'Me'0a' a 0 0 0 Lmstransfer 0 0 0 0 Recrieribulion 0 0 0 0 14 Subbte 335 2501 426 228 15 Ductloads 31%1 481/61 104 1194 31% 48% 133 109 Total room load 1 1 439 3695 559 336 AirrectUred(dhi) 21 162 27 15 .4ft PjgMtiLOLkiOM1201919.0.07R51N18I0I ..mamerb�WdgtboftWAMVVYNNr-TFESTERLINGrw Cdc=WS FmrtDoorfa=N 9:31:11 Pa96 3 wrightsoft- RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By,. 317 ST. LUCIE LN, FF. PIERCE. FL 34946 More: 772466-6799Fax772466-6796 Emit: OUICKCALCS@AOL.COM I Room name BEDROOM2 ENTRY 2 Exposedvafl 32.2 It 7.0 It 3 Room height 8.0 it hwV=l 8.0 it heatbool 4 Room c[imenslorei 1.0 x 203.5 ft 1.0 x 55.0 it 5 Roomarea 203.5 f? 55.0 IF Ty Construction U-%due Or HTM Area (q Load Area (W) Load number (BulfifLIl') (Btuh" or perimeter (f) (Billh) or perimeter (11) (Btuh) He; Cad Gross NYRS Heat cool Gross NIP/S Heat Cool 6 i" 0143' M" - �,--4.06 "255 128,1-, 128 513 0, 0 .0 xojbm�� -' . - 1�ii5 �'M, 3556, 70.43 -17 '0 : -0 0- - j Or" -.':�O I- : , � 0 �O V,v 13A4ocs 0.143 se 4.00 2.55 80 .56 225 143 4 26 106 67 F—G IAclorn 1270 as 35.56 34.77 24 24 US 829 0 0 0 0 r, 0.390 M 10.92 11.31 0 0 0 0 22 22 238 244 _ V, -' I � A 3A;,4= - ' .0 f43 4.60 �Z55 -3V 34 136 tis r,- "0 - - w 13k4cm 1A-G1om 0.143 4.00 2.55 16 16 64 41 8 8 32 -0 20 -z '13A4a' aAclom 1270 '0143 .1270 w rW IW 35.58 -4GO 4291 Z55 ,`:45.24 0 �1� OZ.- 0 ","-0 - -0 0 0 0 -0 0 0 -,'0 0 4* 11 10 0 -10 0 0 0 0 In .0.770 2156 27A 0. :�� 0 4-0 '0 A !'-,o 0 -D p 12C-Ow 0.091 155 1.28 a a 0 0 72 72 183 92 'C .164-30mkd 0.032 `-,--"0.90 232 '204 --1. ,2D4 182 472 - 55 55 - 49 "128 F ..0.989 27.69 0.0.0 204 32 891 0 55 7 194 0 J , 41 :2 6 c)AEC emnim -24 -61 EmelopelossIgain 2859 1873 SOD 645 12 a) lrt5Fa;Mon 564 154 122 34 b) Roomverrfilafion 0 0 0 0 13 Intarrialgain O=Wnb@ 230 1 230 0 0 Apprianceslother 0 0 Subtabl(lines6to13) 3422 2257 M .579 Leeseedemallow 0 0 Ol 0 Les;transfer 0 0 0 0 Redishib0on 0 0 0 0 4 I1 Subtotal 3422 2257% 922 579 15 Ductloads 319/61 lf� In W/. AM-1 I., Ana Root-SLiteaLkiwrsal20l9l9.0.07RSLIOB101 ..MameNs\WdohtsdHVADWYNNE.TFESTERLNGAp CaIc=MJS FrortDoorfaces:N 1209 59 2019�Sep-1709;31:11 Page4 wrightsoft- Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN.. Fr. PIERCE, FL 34946 Phom:772-468-8799 Fax772-466-6796 EMjI:QUlCKCALCS( A0L.00M I Roomrme LAUNDRY GREATIDINING 2 bposeclMd] 6.0 ft 46D It 3 Room height 8.0 ft heaftol 8.9 ft hmt(=l 4 Rocarri climensiors 7.0 x 6.0 It 1.0 x 488.0 ft 5 Room area 420 fe 488.0 ft2 Ty Consfirdon U-value Or HTM Area(fe) Load Area On Load number (Btulifttq (BluhdTj or penmetar (f) (BLh) or perimeter (t) (Sw Heat Cod Gros N/RS Heat C.1 Gross, I NIPS Heat I Cool 6 t -ISA;4661 '00 -255 - - �70 0 0 0 c. 231 IN 5% -:,�493 �2' 12M 70.43 :-0 �o 0 .0 :1 38 �O 1W 12662 w 13AA= 0.143 sa 4.00 2M a 0 0 0 a 0 . 1) , 1, 0 E—G IA�clom 1270 w 35M 34.77 0 0 0 0 0 a 0 0 11DO 0.390 se 10.92 1131 a 0 0 0 a 0 0 0 0.143 �';s' -400 -";Z55 --o 0., 0:, 4 :, o -:0 Y--G 13A-4= 0.143 m 4.00 2.65 48 48 192 122 0 0 0 0 1A-lom 1270 w 35.56 4Z91 0 a 0 0 0 0 0 0 4A-dam.; '0.143 ��-1270 lmw � 06 _,35M �' Z55 _45.24 0 �---o 0 a 0 0 ;O �o '178 1 ) 137 0 '�54§ - 0 "-�34 1L.1 9 0 AAS -261t�' .776 nN :21.56 ,Z7.54 o�() 0 0,�. •.o 41 �O - 1: 880 P 12C-Ow 0.091 255 128 56 56 143 72 0 0 0 0 C 16006 a --- -; 0 :6 32 �w� 0 .90, I , - 2.32 A2 - t 742 "97 ---48 8 �488 F 224-V - - - - 0.989 27.69 0.00 42 6 166 0 , 46, 1274, _1132 -z' - - 2. M, z 6 c) AED mcurston 31 EnvelpelossIgain 539 288 5259 12 a) Infiltration 105 29 895 245 14 b) Roommen5latton 0 0 0 0 13 Intarrialgaim O=ipant3@ 230 0 0 2 60 1 1.) 1 5441 317 1 1 6154 m I Lessademalload 0 0 �0 0 Lesstransfer 0 0 0 0 Redstriletdon 0 0 0 0 14 Subletal 644 317 6164 6409 15 Ductloads 31-A 48% 200 151 31%� 48% 1913 3060 Total voorIi load 844 468 8067 Nag Air reqdmd (cfm) 41 21 393 416 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrLOF c - 2019,8ep-170911.11 —M�m Pigit-SiiLOLkfmml201919.0.07RSLI08101 �=nftWdgtbOftWAMWYNNE-THESTERLINGAP CaIc=MJS FrortDoorfacer. N Page 5 # wrightsoW Duct System Summary a�: Entire House 6y. QUICK CALCS, INC. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phore:772-466-6799Fac772-466A796. Email OUICKCALCSQAOL.COM _ For. WYNNE DEVELOPMENT THE STERLING, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowestfriction rate Actual airflow Total effectivelengol (TEL) _ Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.260 / 0.250 in H2O 0284 in/100ft 1160 Ciro Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0250 in H2O 0.284 in/100ft 1160 din 176 ft - - Name Design (Bluh) Htg (Ciro) CIg (Cfm) Design FR Diam (n) H x W (in) Duct Mad . Actual Ln (ft) Fig.Egv Ln (ft) Trunk BATH h 559 27 15 0.316 4.0 OxO VIFx 18.1. 115.0 sti BEOROOM2 h 4486 218 146 0.374 6.0 OxO VIFx 18.6 115.0 st1 ENTRY h 1209 59 38 0.510- 4.0 Ox0 .VIFx . 3.0 95.0 GREAT/DINING c 4735 196 208 0.318 7.0 Ox0 MFx 22A 135.0 st2 GREATNIMNG-B c 4735 196 208 - 0.307 7.0 OxO VIFx 28.1 135.0 s12 THEN c 3695 21 162 0.375 7.0 OxO VIFx 18.3 115.0 st1 LAUNDRY h 844 41 21 0.366 6.0 OxO VIFx 21.6 115.0 st1 M. BATH h 1162 57 54 0.366 4.0 OxO VIFx 21.6 '115.0 st1 MASTERBEDROOM-A h 3501 170 149 0,297 6.0 OxO VIFx 33.1- 135.0 st2 MASTERBEDROOM-B h 3501 170 149 0.284 6.0 Ox0 VIFx 41.1 135.0 st2 wG o 214 4 9 0.310 4.0 Ox0 VIFx 26.3 135.0 st2 Trunk Htg Clg Design Ueloc Diam HxW Duct Name Type (cfm) (Cfm) FR (fpm) (in) (n) Material Trunk an PeakAVF 737 724 0284 938 12.0 0 x 0 VinlFlx st1 Bill PeakAVF 1101 1122 0.284 1050 14.0 0 x 0 VinlFlx wrightsoft' �zBlasep-n69ae11 � .�... «...,m.., RigW&R-® LYiversa1201919.0.07 RSU06101 Page 1 aa+nettls\Wrigrb'oriFNACiWYNf�-TFfl=STERLINGnp CaIc=MJe Fmrt Oaorfa�s: N Name Grille Size (in) Htg (Cfm) Clg (dm) TEL (ft) Design FIR Veloc (fpm) Diam (n) HxVV (n) Stud/Joist Opening (n). Dud Mat! Trunk rb1 Ox0 1 1160 1160 0 0 0 0 Ox 0 MR wrightsoft- 20195ep-1709a1:11 Rgh6Sdte8Utisersal 201919A.07 RSU08101 Page fR.1.R ...or6slWiigNsaftWACkWYNNE-TFESTERLNGnp Calc=MJ8 FroRDoorfacesN