Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENE GY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Departm t of Business and Professional Regulation - Residential Performance Method Project Name: 10603Pini Needle drive Builder Name: Mike DiFrancesco SCANNED Street 10603 Pin Needle drive Permit Office: St Lucie BY City, State, Zip: Fort Piero , FL , 34945 Permit Number: St. Lucie County Owner: Timmons Jurisdiction: 611000 Design Location: FL, Fort Pi rce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or erdsting New (From Plans) 9. Well Types (2667.0 sqft.) Insulation Area a. Concrete Stock- Polystyrene Bead A9glR=0.0 2097.00 W 2. Single family or multiple fam' Single-family b. Frame - Wood, Adjacent R=13.0 570.00 ft' 3. Number of units, if multiple fat illy 1 c. WA R= ft= 4. Number of Bedrooms 4 d. WA R= ft' 10. Ceiling Types (2529.0 sqft.) Insulation Area 5. is this a worst case? No a. Roof Deck (Unvented) R=20.0 2529.00 fF 6. Conditioned floor area above Irade (ft2) 2529 b. WA R= ft c. NIA R= ft' Conditioned floor area below rade (ft') 0 11. Ducts R R2 7. Windows(279.6 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 368 a. U-Factor. Dbl, U=0.34 101.19 ft= SHGC: SH b. U-Factor: Dbl, C=0.23 U=0.34 97.13 fl' 12. Cooling systems kBtufhr Efficiency a. Central Unit 36.4 SEER:17.00 SHGC: SHO C=0.31 c. U-Factor. Obl, U=0.33 69.33 fft SHGC: SH C=0.24 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 12.00 ftr a. Electric Strip Heat 34.0 COPA.00 SHGC: other (see details) Area Weighted Average Over rang Depth: 6.985 ft. Area Weighted Average SHGC: 0.261 14. Hot water systems a. Propane Tankless Cap: 1 gallons 8. Floor T ypes ( 2529.0 sgft.) Insulation Area EF: 0.59090 a. Slab -On -Grade Edge Insuh lion R=0.0 2529.00 ft' b. Conservation features b. WA R= ft' None c. WA R= ft' 15. Credits CF, Pstat Total Proposed Modified Loads: 84.99 PASS SS Glass/Floor Area: 0.111 Total Baseline Loads: 85.30 /•1 �7 I hereby certify that the plan and specifications covered by Review of the plans and ` f KIAE Sri this calculation are in comp) Code. ance with the Florida Energy specifications covered by this calculation indicates compliance `'',•L„f0 with the Florida Energy Code. ,,,"•' •-` is PREPARED BY: Before construction completed a DATE: D - this building will be inspected for o c compliance with Section 553.908 a *f I hereby Florid that this boil with the Florida Energy Cod . as designed, in compliance Florida Statutes. z Y E CCfl lYE'� OWNER/AGENT: BUILDING OFFICIAL: D- DATE: DATE: -Compliance requires ceitification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. -Compliance requires an 'r Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). G � SDI 1015/2019 3:52 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 I urnr rT cl meeewoV cuf=CK1 ICT RFPART I-UKMK4U0-ZUl! PROJECT Title: 10603Pine t eedle drive Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2529 Lot# Owner Name: Timmons Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Mike DiFrani esoo Rotate Angle: 0 Street: 10603 Pine Needle drive Permit Office: St Lucie Cross Ventilation: County: St. Lucie Jurisdiction: 611000 Whole House Fan: City, State, Zip: Fort Pierce , FL, 34945 Family Type: Single-famiN New/Existing: New (From T Ilans) Comment CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site' 97.5 %, 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 2529 26190.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2529 26190.3 Yes 1 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade E dge Insulatio Main 277 R 0 2529 it' — 0 0 1 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Bart Absor. Tested Tested Insul. (deg) 1 Hip Metal 2828 112 0 ft2' Unfinishe N 0.35 No 0.4 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC ' 1 Full attic Unvented 0 2529 tt2 N N CEILING # Ceiling Tyl is Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Atli (Unvented) Main 0 Blown 2529 f12 0.11 Wood 10/5/2019 3:52 PM I EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 .., ' w' 1rl Wl rQT nronoi FORM R405-2017 INru I aumIIVIMM I WALLS Adjacent Cavriy Wig "a" Sheaffiing Framing Solar Bellow Space P ncrete Block - Polystyren Main 41 10 410.0 ft' 0 0 0.600000 0 1 N Exterior C _ 2 N Exterior C norete Block- Polvstyren Main 12 12 8 152.0 11 0 0 0.600000 0 _ 3 E Exterior ncrete Block- Polystyren Main 64 0 10 640.0 fF 0 0.600000 0 _ 4 S Exterior onrrete Block- Polystyren Main 20 8 10 206.7 ft' 0 0.600000 0 _ 5 S Exterior oncrete Block - Poystyren Main 17 10 170.0 fI2 0 0.600000 0 _ 6 E Exterior oncrete Block - Polystyren Main 4 3 10 42.5 ft'0 0.600000 0 _ 7 BE Exterior oncrete Block - Poystyren Main 3 2 10 31.7 fP 0 0.600000 0 _ 8 S Exterior oncrete Block - Polystyren Main 34 9 10 347.5 fF 0 0.600000 0 _ 9 W Exterior oncrete Block - Polystyren Main 9 8 10 96.7 W 0 0 0.600000 0 _ 10 W Garage F rame - Wood Main 13 35 4 10 353.3 ft2 0 0.23 0.600000 0 _ 11 N Garage F came -Wood Main 13 21 8 10 216.7ft2 0 0.23 0.600000 0 DOORS # Omt Door Type Space Storms U-Value Width Ft In Height Area Ft In 1 N Insulated Main None .21 2 8 8 21.3 ft2 _ 2 N Insulated Main None .21 6 7 42f12 WINDOWS Orientation shown is the entered, Proposed orientation. Overhang Wall NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening # Omt ID Fra ne Panes 1 N 1 Vu iyl Low-E Double Yes 0.34 0.31 Y 64.9 ft2 2 ft 0 in 1 ft 01n None None _ 2 N 2 Vii iyl Low-E Double Yes 0.3 0.24 Y 12.0 ft2 8 It 0 in 2 ft 0 in None None _ 3 E 3 Vii iyl Low-E Double Yes 0.34 0.31 Y 32.4 f12 2 It 0 in 1 It 0 in None None _ 4 E 3 Vii n4 Low-E Double Yes 0.34 0.23 Y 7.1 112 2 It 0 in 1 It 0 in None None _ 5 S 4 Vi iyi Low-E Double Yes 0.33 0.24 Y 21.3 ft2 7 It 0 in 1 ft 0 in None None _ 6 S 4 Vi ryl Low-E Double Yes 0.34 0.23 Y 16.21t2 7 It 0 in 1 ft 0 in None None _ 7 S 5 _ Vi iyl Low-E Double Yes 0.33 0.24 Y 48.0 ft' 13 It 0 in 1 ft 0 in None None _ 8 S 5 V iyl Low-E Double Yes 0.34 0.23 Y 22.8 fF 13 It 0 in 2 ft 0 in None None _ 9 E 6 V, TA Low-E Double Yes 0.34 0.23 Y 16.2 ft2 17 It 0 in 2 It 0 in None None _ 10 SE 7 V nyl Low-E Double Yes 0.34 0.23 Y 16.2 ft2 9 It 0 in 2 ft 0 in None None _ 11 S 8 V nyi Low-E Double Yes 0.34 0.23 Y 22.8 ft2 2 It 0 in 1 Ito in None None GARAGE # Floor ea Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 674.01 674.01 ft2 51 ft loft 1 1015/2019 3:52 PM I EnergyGauge® USA 6.0.02 (Rev. 1) - RaReS2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Methoc SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed CH(50) .000329 2182.5 119.82 225.34 .1264 5 HEATING SYSTEM # System Type 1 Electric Strip H eatf Subtype None Efficiency Capacity COP:1 34 kBtulhr Block 1 Ducts sys#1 COOLING SYSTEM # System Type 1 Central Unit/ Subtype None Efficiency Capacity Air Flow SHR SEER: 17 36.4 kBbAr 1092 cfm 0.75 Block 1 Ducts sys#1 HOT WATER SYSTEM # System Typ 1 Propane SubType Tankless Location Exterior EF Cap Use SetPnt Conservation 0.59 1 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS —ppty— # Location R-Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 368 fN Attic 126.45 f Default Leakage Garage (Default) (Default) 1 1 _ TEMPERATURES t Programable Thermostallov XJan]]Y VCoolingenting JanJan [) F b Mar [X] AAppr C[[eiling Fans: �Xj ] [ ] [ May Jun E ] Jul 4xJ Aug [x] Sep Oct Jun 1 Jul [ 1 Aug [ 1 Sep rjX,j [X] Nov Dec Dec 10/5/2019 3:52 PM I EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 ... w• uwww •mv /'•r =~I ICT OCOnOT FORMR405-2017 INVUI OUlvttvtMFNI ..r,�....�•..• •-�• --•-• Thermostat Schedule: HERS 2C 06 Reference Hours 8 9 10 11 12 • Schedule Type 1 2 3 4 5 6 7 Cooling(WD) 80 80 78 78 78 78 78 78 78 78 76 78 PM 'Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 Heating(WD) AM 66 66 66 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 PM 68 68 68 Heating (WEH) 66 68 68 68 68 68 68 68 68 68 66 66 PM MASS EDefauk(8 Area Thickness Furniture Fraction Space Type Ibsls .ft. 0 tt= 0 ft 0.3 Main 1015/2019 3:52 PM I EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* =100 The I war the Energy Performance Index, the more efficient the home. 1. New home or, addil ion 1. New (From Plans) 12. Ducts, location & insulation level R 6.0 a) Supply ducts 2. Single-family or mu tiple family 2. Single-family R 6.0 b) Return ductsc) AHU location Garage 3. No. of units (if mull pie -family) 3. 1 4. Number of bedroor is 4. 4 13. Cooling system: Capaci 36.4 a) Split system 5. Is this a worst cas( 7 (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor a rea (sq. ft.) 6. 2529 d) Room unitIPTAC EER 17 0 e) Other 7. Windows, type anc a) U-factor.(weig area led average) 7a. 0.336 14. Heating system: Capacity 34.0 b) Solar Heat Gai 1 Coefficient (SHGC) 7b. 0.261 7c. 279.6 a) Split system heat pump HSPF c) Area b) Single package heat pump HSPF c) Electric resistance COP 1.0 S. Skylights a) U-fador.(weig tad average) 8a. NA d Gas furnace, natural gas AFUE ) AFUE b) Solar Heat Gal n Coefficient (SHGC) 8b. NA a Gas LPG Otherurnace, 9. Floor type, insulat on level: a) Slab -on -grade (R-value) 9a. 0.0 9b. 15. Water heating system b) Wood, raised c) Concrete, rais R-value) d (R-value) 9C. a) Electric resistance EF b) Gas fired, natural gas EF 10. Wall type and in ulation: c) Gas fired, LPG EF g 59 d) Solar system with tank EF A. Exterior. 1. Wood frame (n R-value) 10A1. esulation ) Dedicated heat pump with tank EF 2. Masonry (Inst lation R-value) 10A2. 0.0 unit HeatRec% eatOth B. Adjacent: recovery 9) 1. Wood frame (insulation R-value) 1081. 13.0 2. Masonry (Inst lation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type an insulation level 11 a. 0.0 a ) Ceiling fans Yes No b) Cross ventilation a) Under attic b) Single assembly l l b. c) Whole house fan No d) Multizone cooling credit c) Knee wallsfsl d) Radiant barn ylight walls 11c. r installed 11d. No e) Multizone heating credit Yes f) Programmable thermostat 'Label required by action R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this ho ne has complied with the Florida Building Code, Energy Conservation, through the above energy this home before final inspection. Otherwise, a new EPL saving features wh ch will be installed (or exceeded) in display card will be completed based on installed c e compliant features. y _� Date: Builder Signature: r'!� Address of New Home: 10603 Pine Needle drive City/FL Zip: Fort Pierce FL 34945 10/6/2019 3:53:15 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th EdNon (2017) compriant Software Page 1 of 1 velope Leakage Test Report (Blower Door Test) ;side t2 Prescriptive, Performance or ERI Method Compliance 1111114 7 cl, n gZidirfinn r.nritz Pneray Conservation, 6th Edition Jurisdiction: 611000 Permit ;JoO, hfdrmation Builder: Mike DiFramcesco Community: Lot: NA Address: 10603 Pine Needle drive State: FL Zip: 34945 City: Fort Pierce 77 Method Pas§Ing4esuffs!ML66f 6 rthb�IporERt Atr Leakage ,Test.ROSURW" -e 7ry-4 7�7777777777777777777 —77777 building or, dwelling unit shall be tei;tiida'h'd Verified as having an en leakage rat@ f 49, -,P, kif houratra,of TOOD-The pressure -� 11 . - 'lnch�vg�(6o,pascals) in Climate zonei�i 02 changesiper _ Twk,� 7 The Witting or dwelling unit shall be tested an verified as to ['rict adeiaft,,, 4 d' I Q PERFORMANCEakager4 �.ERI METHODf " 66 . Form ., iR4 1 0 . 5-201 - 7( . Pe I rlo 'I lj 16dn-ginnikgon'sijb-.teabn'ACH50. -�s (E111)"saction :the sewed sh�wn `R405-g0 I specified ;4 (b0) on T,-Eq In volume: = Method for calrulggqj�a�grie: x 60 26190 -CF—M(50) Ural plans Building Volume ACH(50) 0 Retrieved from architectural plans F] 'd PASS 0 Code software calculated When ACH(50) calculated is less than 3, Mechanical Ventilation installation 0 Field measured and calculated must be ve Jed by building department. in with ANS11RESNETI]CC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). R402A.11.2 Testing. Testii ig shall be conducted accordance individuals as defined in Section 653.993(5) or (7), Florida Statues -or individuals licensed as set forth in Section Testing shall be conductec by either third party. Awriften report of the results of the test shall be signed by the party conducting the test and 489.105(3)(f),(g),ori7 or to thecode officie an approved 1. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. provided During testing: fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration 1. Exterior windows and d )ors, control measures. ust, intake, makeup air, bark draft and flue dampers shall be closed, but not sealed beyond intended infiltration control 2. Dampers including exh measures. 3. Interior doors, if installs J at the time of the test, shall be open. shall be closed and sealed. heat recovery ventilators 4. Exterior doors for contii wous ventilation systems and 5. Healing and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return regi ers, if installed at the time of the test, shall be fully open. -7r77777 Testing, Company" Phone: Company Name: 1 hereby verify that th a above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservatior requirements according to the compliance method selected above. Date of Test: Signature of Testa Printed Name of T )star: License/Certification #: Issuing Authority: 10/512019 3:53:52 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - HaRes2017 FBC 6th Edition (2017) Compliant Software Page I of 1