PLANS
Inverter Type: Enphase IPV Panel: (18) Axitec 31OW stacking: Q-Rail Light Total Wattage: 5,580W Roof Type: Composition Shingles Wind Load: 7 to 27 Deg Fastener Type: Use 5/16" Dia 4" Lags Sheet Index S-1 Cover Sheet / Site Plan S-2 Detail E-1 One -Line S-lA Mounting Plan General Notes: -Enphase IQ7 Micro Inverter are located on roof behind each module. -First responder access maintained and from adjacent roof. -Wire run from array to connection is 40 feet. O�C�!.��GEN3�•.�L� i 360 -OF 'n cCORIOp •' -Rb Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com Utility Meter -COGEN Disconnect R-2 Located adjacent to # Modules 6 Utility meter ( ) Pitch: 10° Azimuth: 353° R-1 # Modules (12) Ground Access Point Pitch: 10° Azimuth: 173° FRONT OF HOUSE " Meets All Editions of Florida Fire Prevention Code 6th Edition Legend ® Chimney ® First responder access Satellite Utility Meter o Vent Pipe Represents all Fire Clearance 1 st Responder Access D` PV Disconnect including Alternative methods minimum of 36" unobstructed as per Section R324 of the 2015 IRC 2017 FL Residential Code & FBC ,6th Edition (2015 International Residential Code - 2nd Printing modified by the FL Building Standards and Codes 2017 Uniform Code Supplement), 2015 International Energy Conservation Code, County of St Lucie Code, 2014 National Electric Code. Customer Info: Perez Otero 109 SE Solaz Ave, Port St Lucie, FL 34983 ST.LUCIE COUNTY RECEIVED PLAN REVIEW BLDG: OCT 0 S -919 DATE^f*rA 11ACCeS ST' lie County, Permitting PLUMB: SCANNED DATE: BY MECH: St. Lucie County DATE: 3' Access Pathway MIN. SETBACK FRONT ©� SIDES �— MRSIDE ZNG. TECH 0� �. - OF O Layout Subject to Change Based on Site Conditions FLORID UUER 1331 Green Forest Ct, Ste 3 Winter Garden FL, 34787 407-926-0233 Date: 9.15.19 N Drawn by: T? 1 � Checked by: Rev #• 00 + Rev Date: Page: S-1 Com ap ssforAe A. Roof Attachment B. Q Rail Light C. Mid Clamp D. End Clamp E. Internal Q Splice General Notes: - L Feet are secured to roof rafters. @ 48" O.C. using 5/16" x 4" stainless steel Lag bolts. - Subject roof has One layer. - All penetrations are sealed and flashed. Roof Section Pitch Roof Rafter and Spacing Overhang Notes: R1-R2 2/12 211x4" @ 24 O.C. Designed as per ASCE7-10 Modules mounted flush to roof no higher than 6" above surface. 1211 I Truss Inverter Type: PV Panel: Racking: Total Wattage: Roof Type: Wind Load: Fastener Type: Enphase (18) Axitec 31OW Q-Rail Light 5,58OW Composition Shingles 7 to 27 Deg Use 5/16" Dia 4" Lags Info: Perez Otero 109 SE Solaz Ave, Port St Lucie, FL 34983 soles Module 3/6-16 x 3/4 HEX HEAD BOLT 3/6-16 FLMM NUT 3-5/8" Godwin Engineering and ®O,•'�%C EtiS j ' VX. Design, LLC ;' 360 y 8378 Foxtail Loop -a , Pensacola, FL 32526 ®.. ' re of D. Chad Godwin, PE i F '• �ORIDP.-' ��� Chad@godwineng.com//s)olyg ENG��I%!l/r FLOReDLP 17TER K f. li �' Exy, 42 �' 1331 Green Forest Ct, Ste 3 Winter Garden FL, 34787 407-926-0233 Date: 9.15.19 Drawn by: 3P d"hPekPd hv Rev Date: I S-2 �raro-M ve-posmarro Slt.'S000IIPlSRlB4 aaopnwran ayrawcuz. Figure 690.56(C)(1)(a) Label for PV Systems that Shut down the array and the conductors leaving the array # 12 AWG TH WN for Home runs under 100' 910 AWG TH WN for Home runs over 100' (1) Line 1 (1) Line 2 Per Circuit #8 AWG THWN (1) EGC Inside @ least 3/4" Conduit (tbd on site) Main Service 200A 200A Bus Utility PV AC Disco (IfRefd) 130A 60A Non -Fused Disconnect io e Optional load de connection when available Per 705.12 D 2 3 b Use Matching or equivalent approved breaker if derating Load Side Connection PHOTOVOLTAIC BusbarRafin 200 Main Break*r Size 200 Bus Rafin L2-Main Break We 40 Max Allowable Load Side 40 Load Size Breaker Size 30 SYSTEM A AC D3SCONNECT L► NEMA 3R En a e Cable Junction Box Black - Ll Red - L2 Green - Ground solardeck Typ Enphase Combiner Box (1) - 20A Breaker Per Circuit Disconnect ! INVERTER OUTPUT CONNECi1KSN . :DO NOT RELOCATE THlSOVERC[JRRENT M..6.e,w DEVICE In Case of Emergency Call Florida Power Management at 407-926-0233 (1) Line 1 (1) Line (I) Neutral #8 (1) EGC in (a) leas[ 3/4" Conduit Note: -All wiring to meet the 2014 NEC and Florida electric codes. 60A Disconnect -Type of conduit to be determined on site by contractor. Photovoltaics: (18) Axitec AC-31OW60S Inverters (18) Enphase IQ7 Micro Inverters Circuits: (1) circuit of (12) Modules (1) circuit of (6) Modules Roof Maximum Inverters Per 20A Circuit (16) Line Side Tap 60A Service Rated Puled Disconnect Neutral to Ground Bond AC Disconnect 30A Fuse #6AWG THWN (1) Line 1 (1) Line 2 (1)Neutral _ in 3/4" Conduit Typically (1)#8 A WG EGC &GEC GEC NOTES Provide a grounding electrode system for an ungrounded system per 690.47(C)(3). - GEC must be installed per 250.64 - GEC must be continuous tin -spliced or irreversibly spliced from inverter to existing service ground system or continuous from the arrays to the existing service ground system. - If GEC is not continuous from the artay to the existing service ground an additional ground system must be provided from the arrays to a grounding electrode per 690.47(D) - GEC must be min 48 AWG and installed in conduit O AC Distribution Panel or Sub Panel Ref to NEC 312.8 for Condmons on "'Ps"' sw and over wnent devices Ift6e conditions are not mH a tip box will need to be instilled. Customer Info: Perez Otero 109 SE Solaz Ave, Port St Lucie, FL 34983 Enphase Output Ckt Per String To Overcurrent Protection Device AC Max Output Current 12 AC Max Output Current * 1.25% 15 Overcurrent Protection A 20 No. of Current Carrying Cond <4 Conductor Gauge AWG 10 Enphase Total Output Ckt AC Max Output Current 18 AC Max Output Current * 1.25% 22.5 Overcurrent Protection (A 30 No. of Current Carrying Cond <4 Conductor Gauge (AWG) 10 Main Distribution Panel 200A Main Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com 60 ` (�ta.blCENs * I FLORID P W6R k.crlx�e:- 1331 Green Forest Ct, Ste 3 Winter Garden FL, 34787 407-926-0233 Date: 9.15.19 Prawn bv: TP I Rev Date: I E-1 15' R-1 # Modules (12) Pitch: 10' Azimuth: 173 ° 14' 7` 41 - Splice Bar 6 Flashings 42 Mids 30 Ends/End Caps 12 Solardecks 2 Ground Lugs 3 11 Inverter Type: PV Panel: Racking: Total Wattage: Roof Type: Wind Load: Fastener Type: R-2 # Modules (6) Pitch: 10' Azimuth: 353' Max cantilever is 16" as per manufacturer spec. Max Cantilever = Max Span * (1)=48*(1)=16" Enphase (18) Axitec 310W Q-Rail Light 5,580W Composition Shingles 7 to 27 Deg Use 5/16" Dia 4" Lags Customer Info: Perez Otero 109 SE Solaz Ave, Port St Lucie, FL 34983 1-1 n 5 1 ' `\\\ta�� 1C r Go "//�i ce116Godwin Engineering and Q\-7 y Design, LLC * : $� o 8378 Foxtail Loop Pensacola, FL 32526®t rE of ; D. Chad Godwin, PE �� F'• °CORIO? Chad@godwineng.com s owi Exx�����/9 Rev #: 00 Rev Date: FLOR IIP WER k �C NA. c� "' 1331 Green Forest Ct, Ste 3 Winter Garden FL, 34787 407-926-0233 9.15.19 TP S-1A