Loading...
HomeMy WebLinkAboutPLANSFBC APPROVED PRODUCTS, IT TABLE t MAXIMUM ALLOWABLE RAFTER rrT..ME, END POST, GROUND ANCHORAND PANEL FASTENER SPAC/NG SPECIFICATIONS WIND SPEED PRODUCT CATEGORY I SUBCATEGORY STRUCTURAL COMPONENTS ROOF DECK STRUCTURAL COMPONENTS I STRUCTURAL WALL STRUCTURAL COMPONENTS I FLOOD VENT EXTERIOR DOORS EXTERIOR DOORS EXTERIOR DOORS EXTERIOR DOORS SWINGING SWINGING ROLL -UP ROLL -UP MANUFACTURER CAROLINA CARPORTS, INC. 26 Gauge AG Panel CAROLINA CARPORTS, INC. 26 Gauge AG Panel FLOOD FLAPS, LLC 8x16 Flood Flap ELIXIR DOOR AND METAL COMPANY Series 402-14 ELIXIR DOOR AND METAL COMPANY Series 407 CAROLINA CARPORTS, INC. Steel Roll -Up Sheet Door- 8' Wide CAROLINA CARPORTS, INC APPROVAL No. & DATE CIA EXPIRATION DATE FL6596.1-R5 04/05/27 10/10/17 FL6702.1-R5 03/14/27 10110/17 FL17381.1-R2 09/27/19 10/03/17 FL17996.3-R1 09/14/20 01/29/18 FL17996.5-R1 09/14/20 01/29/18 FL16806.2-R4 11/11120 06/18/19 FL16806.4-R4 11/11 /20 PARTIALLY OPEN ENCLOSED JENCLOSED 180 180 1 180 180 I 180 I 180 N/A N/A N/A N/A 156 1 131 N/A 165 147 N/A I 180 I 180 WA 180 172 AVERAGE FASTENER SPACING ON -CENTERS ALONG RAFTERS OR MAXIMUM PURLINS, ANDWOSTS OR•GIRTS WIND ULTIMATE NOMINAL POST/RAFTER (INCHES) INTERIOR END RISK EXPOSURE WIND SPEED WIND SPEED SPACING CATEGORY CATEGORY (MPH) (MPH) (FEET) POSTS/RAFTERS POSTS/RAFTERS 71, 1 TO 150 89 T 110 6 5.0 6 I C 151 TO 180 I 117 TO 139 4.0 6 6 NOTES: 1. Specifications applicable to 26 gauge metal roof and wall panels fastened directly to 12 or 14 gauge steel tube framing, or 18 gauge hat channel roof purlins. 2. Specifications applicable only for mean roof height of 20 feet or less, and roof slopes of 7' to 27° (1.5:12 to 6:12 pitch). Spacing requirements for other roof heights and/or slopes may vary. 110 ULTIMATE 160 170 Steel Roll -Up Sheet Door -19 Wide 06/18119 ` 16 ' t0x EXTERIOR DOORS ROLL -UP CAROLINA CARPORTS, INC. FL16806.1-R4 11/11/20 N/A 179 154 = 18 Steel Roll -Up Sheet Door- 17Wide 06/18119 20 e EXTERIOR DOORS ROLL -UP CAROLINA CARPORTS, INC. FL16806.3-R4 11A1/20 N/A 155 133 r7 22 Da0110 Steel Roll -Up Sheet Door - 16'Wide 06/18/19 0 24 EXTERIOR DOORS ROLL -UP ASTA INDUSTRIES, INC. FL8888.01-R5 12/31/19 N/A 180 174 26 Model 203 - Max. 12' Wide 10/06/17 m 28 cho LNU:il WINDOWS SINGLEHUNG MI WINDOWS AND DOORS FL17499.1-R5 10/17/23 N/A 175 157 30 1C Model 185 SH 03/27/19 DETAILS ICAND 1 D SHOWN ON SHEET 4 OF 6 NOTES: I DOORS AND WINDOWS SHOWN MAY BE SUBSTITUTED FOR DIFFERENT PRODUCT LINES ANDIOR MODELS, PROVIDED THE FOLLOWING CONDITIONS ARE MET' A. PRODUCT SHALL HAVE A VALID FBC PRODUCT APPROVAL. ' B COMPONENTS ARE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION REOURIEMEWS ��;���®®� 2. FRAMING CONNECTIONS FOR DOOR AND WINDOW FRAMES REMAIN THE SAME FOR SUBSTITUTED PRODUCTS. HEADERS AND WINDOW RAILS MAY BE RAISED OR LOWERED AS NECESSARY TO ACCOMODATE®®,'• E1�D�IAII-�/� COMPLIANCE SUBSTITUTED PRODUCT. c 4 p y g/� ®UN 0. B�FJ`V'E GENERAL NOTES: 1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT0 PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. 2. S IHUGTURES'ARE,DESIGNED'AS. NON -HABITABLE' UTILITYSTORAGE BUILDINtiNGS-(MSK-CA7EGORY7�79FA�LEOF'SUPPORTIll-a DEADYOADOFTHESTRLICTURE-ANDAPPL-ICABCELIVEANDWINDtOADS-IMPRQ MENTS S NOT SPE 7FI'CAL1l'ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR O`I'F1E'R-cONIP6NENTS-NOT-tlsTEDiNTREBBC AP-P' OVED PRnUC'1' ISS-C T (T-HTS-SREETj,`AND'NOT'PROVIDED-MmiiSTACEDBY-CAROLINA 7U CARPORTS, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC., SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS, T A 3. ALL STEEL TUBING SHALL BE 50 KSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL. 4. ALL COMPONENTS AND CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS, AI,!Z Rf3A -MEEE F HT E D__ESIGNIPRESSU_R_ES'R_EQUIRED_B)'_T�HT- �IEFLOR �UICDINGCODE(FBCpAT'THqjeME-^^-� AUON.OF�THSDTCDINGWITHIN-THESTATFOF-ram 5. ALL FIELD FRAMING CONNECTIONS SHALL BE #12-14 x 3/4' SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED. 6. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6X6-W1 .4XW1 .4 WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116. 7. BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6' OF EVERY POST LOCATION, AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT REQUIRED FOR CONCRETE FOOTING AND/OR CONCRETE SLAB CONSTRUCTION. SEE GROUND ANCHOR SCHEDULE (THIS SHEET) FOR SPECIFIC TYPE GROUND ANCHOR REQUIREMENTS. 8. CONCRETE ANCHORS SHALL BE TAPCON REDHEAD LOT 1l2' x 5' OR EQUIVALENT OR WEJ-IT ANKR-TITE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT. FILE C O PY 9. POST/RAFTER BRACING: BRACE ON EVERY POSTIRAFTER CONNECTION, EXCEPT FOR END WALLS. P 10. SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FBC SIXTH EDITION (2017) - RESIDENTIAL, AND SECTION 1816.1 OF THE FBC SIXTH EDITION (2017) - BUILDING. MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT BEARING PRESSURE OF 2.000 PSF IS ASSUMED. 11. 14 GA FRAMING: 2-112' x 2-112' TUBE STEEL (TS) WITH 2-1/4' x 2-1/4' TS NIPPLES. 12 GA FRAMING: 2-1W x 2-1/4' TS WITH 2' x 2' TS NIPPLES. 12. ENCLOSED AREAS REQUIRING FLOOD OPENINGS MUST HAVE A MINIMUM OF TWO (2) OPENINGS ON EXTERIOR WALLS. OPENINGS SHOULD BE INSTALLED ON AT LEAST TWO (2) SIDES OF ENCLOSED AREA, WITH BASE OF OPENINGS SET WITHIN 1-FOOT OF THE HIGHER OF INTERIOR OR EXTERIOR GRADE. REQUIRED TOTAL NUMBER OF FLOOD VENTS NOTED IN THE FBC APPROVED PRODUCTS LIST SHALL BE BASED ON ONE It FLOOD VENT PER EVERY 220 SQUARE FEET OF ENCLOSED AREA. SEE TYPICAL FLOOD VENT FRAMING PLAN, SHEET 5 OF 6. METAL CARPORT INSTALLATION PLANS AND DETAILS AND FRAMING AND FASTENER SPECIFICATIONS FOR-GONSTROCTTON7N TiiE-STATE-OEFLORIDA PREPARED FOR: CAROLINA CARPORTS, INC. P.O. BOX 1263 DOBSON, NORTH CAROLINA 27017 PREPARED BY. BECHTOL ENGINEERING AND TESTING, INC. 605 WEST NEW YORK AVENUE DELAND, FLORIDA 32720 Certificate of Authorization No. 00005492 RECEIVED OCT 0 8 2019 ST. Lucie County, Permitting SCANNED BY St. Lucie County VI,C. \��, R H • �,, Off'' VCENS '•.'S' �� BECHTOL ENGINEERING ANp TESANG3NF8 605 WEST NEW YORKAVENUF DELAND. FLORIDA a2T20 CnnlSwb or No. Q\ C STATE OF Thame .E i��`s'•.FCORIDp;. ''GN FkMa Llm No. /Ifllllll\\\\\\\\ CAROLINA CARPORTS, INC. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA 7/15/19 BECHTOL ENGINEERING RR _ _ NTs AND TEST1111fy Lie rmaieo�ro,ri�en.r¢mws�e,e,mme� '� RR n G19001 TS SHEET10F6 BOW FRAME RAFTER OPEN CARPORT - HORIZONTAL ROOF BOW FRAME RAFTER ENCLOSED BUILDING - HORIZONTAL ROOF BOW FRAME RAFTER UTILITY BUILDING - HORIZONTAL ROOF FLOOD VENT (As eppOmge) ROLLdIPDOOR SWINGINGDOOR ROLL -UP DOOR SWINGING DOOR (As applicable) (AsappllcaNs) (As appriceNe) (As SpWirade) _ TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL S10E ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION NOT TO SCALE NOT TO SCALE NOTTOSCALE NOT TO SCALE NOTTOSCALE NOTTOSCALE BOX EAVE FRAME RAFTER OPEN CARPORT - HORIZONTAL ROOF BOX EAVE FRAME RAFTER ENCLOSED BLDG - HORIZONTAL ROOF BOX EAVE FRAME RAFTER UTILITY BLDG - HORIZONTAL ROOF FLOOD VENT (As epprimNe) ROLL -UP DOOR SWINGING DOOR ROLL -UP DOOR SWINGINGDOOR (As eppScaeie) (AS ePP6mbie) (AS SW=ble) (As aWcable) q _ _ W(idiftdiYP.ICALIEND ELEVATION 1,I,;_TcS„_; TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TO SCALE NOT TO SCALE NOTTOSCALE NOTTO SCALE BOX EAVE FRAME RAFTER OPEN CARPORT - VERTICAL ROOF BOX EAVE FRAME RAFTER ENCLOSED BLDG - VERTICAL ROOF BOX EAVE FRAME RAFTER UTILITY BLDG - VERTICAL ROOF FLOOD VENT (As apPEble) ROLL -UP DOOR SWINGINGDOOR ROLL -UP DOOR SWINGING DOOR RIB Imil (As aWcaNe) (As epp6wble) (As Wade) (As app6®bie) ` LLL cLOseo LEWdIRVAI3E TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION NOT TO SCALE NOTTOSCALE NOTTOSCALE NOTTOSCALE NOT TO SCALE NOTTOSCALE \\\"Nj%jI DI))),//// SAS R BECHTOL ENGINEERINI AfS TESTING, INC. % 605 WESr NEW YORK AVENUE— •• O DELAND, FLORIDA 32720 No. 3853 r Cedifitate o/ Goa _ I. P.E� u,a.p ••. STATE OF Raida CAROLINA CARP61 .„ , • i\\� GENERIC PLANS FOR USE IN THE STATE OF FLORIDA TYPICAL BOW RAFTER GABLE END ELEVATION TYPICAL BOX EAVE RAFTER GABLE END ELEVATION TYPICAL BOX EAVE RAFTER GABLE END ELEVATION NOTTOSCALE NOTTOSCALE NOTTOSCALE �BECHTOLENG/NEER/NG -•— RR Nrs AND TESTING, M. morn.cconc..muneao:..r.�..mW�ns-cuc,a..a '®RII RR Y0' G19007 TB sHEEr20FS -1� 26 GA GALVANIZED METAL ROOF PANELS FASTENED TO RAFTERS PER MANUFACTURERS INSTALLATION INSTRUCTIONS 12 J —2C 16 GA UCHANNEL BRACE FASTENED TO RAFTER WITH (2) #12-14 x 314' SDFs AT EACH END (4 PER BRACE) 2VNAI URAPIERSPANONSINGLERAPIER .24'TO3PRAFTERSPANREOWp ATR FDY TYPICAL INTERIOR RAFTER/POST FRAME SECTION - BOW FRAME NOTTOSCALE LENGTH VARIES DEPENDING ON ip4ZmX•1, , I SIDE WALL 26 GA GALVANIZED METAL ROOF PANELS FASTENED TO RAFTERS PER MANUFACTURERS NSTALLATION INSTRUCTIONS 7 12 �1�\tee Q3 >2V W'1Tn10 24' 16 GA U-CHANNEL BRACE FASTENED TO RAFTER WITH (2) 412-14 x 3/4' SDP's AT EACH END (4 PER BRACE) SEE TABLE 1 SHEET TYPICAL RAFTERROST FRAMING PLAN - BOX SAVE NOT TO SCALE SEE TABLE 1 OPENING FOR SWINGING SHEET DOOR WITH NONSTRUCTURAL I OF HEADER OPTIONAL 24'-1" TO 30' TRUSSED RAFTER - BOW NOT TO SCALE SEE TABLE 1 SHEET 12 SEE TABLE 7 SHEET s IOF6 4 LENG VARIES DEPENDING NUMBER AND SPACING OF RAFTERS TE 26 GA GALVANIZED METAL ROOF PANELS FASTENED TO PURLINS PER MANUFACTURER'S GAUGE FURRING -24' 16 GA U-CHANNEL BRACE FASTENED TO RAFTER WITH (2) #12-74 x 3/4' SDFb AT EACH END (4 PER BRACE) RAFTER SPAN ON SWRAPIER TYPICAL INTERIOR RAFTER/POST FRAME SECTION - VERTICAL ROOF NOT TO SCALE 1-72' 78 GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER WITH (2) #12-14 x 3/4' SELF -DRILLING FASTENER SPACED NOT MORE THAN 46' O.C. i-6• TYPICAL POST/RAFTER FRAMING PLAN - VERTICAL ROOF NOT TO SCALE TYPICAL ROOF EXTENSION OPTION END WALL OPENINGS POST/RAFTER FRAMING PLAN TYPICAL LEAN-TO OPTIONS F NOT TO SCALE NOT TO SCALE (BOX EAVE RAFTER 24.16 GA UCHANNEL BRACE (5-TO 7' POST) 48.16 GA U-CHANNEL BRACE (8-TO 14' POST) BRACE ANGLE SHALL BE MIN. 30' BOTH SIDES WELD ALL WEB CONNECTIONS, BOTH SIDES - OPTIONAL 24'-1"TO 30' TRUSSED RAFTER - BOX EAVE NOT TO SCALE LEAN-TO FRAMING PLAN TYPICAL BOW RAFTER GABLE END FRAMING PLAN NOT TO SCALE TYPICAL BOX EAVE RAFTER GABLE END FRAMING PLAN NOT TO SCALE 24' 16 GA U-CHANNEL BRACE FASTENED TO RAFTER WITH (2) #12-14 x 3/4' SELF -DRILLING SCREWS AT EACH END (4 PER BRACE) MAIN STRUCTURE BECHTOL Thomas 4SSH thw71 ILE Td• �C C,h �i 1' ENS ••yTO�� WAND TESTING, INC.' 1' Bc No.38538 =_ r) STATE �W\ CAROLINA CARPOM 11 C. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA f BECHTOL ENGINEERING m� RR ".MSAND TESTING, Inc. RR f G19861 TB SHEET 3 OF 'INSTALL 12'X MINIMUM 5'TAPCON REDHEAD LOT ANCHOR OR 12' X MINIMUM 5-12' EXPANSION AN( THROUGH BASE RAIL WITHIN 6' OF EACH RAFTER POSTS ALONG SIDES AND EVERY END WALL POSTALONG END WALL SECTIONS X--1 1--2-MINIMUM 2-12' EMBEDMENT MIN.) �._ CNCRBASE RAIL ANCHORAGE DRILL SIB' HOLE THROUGH THE BASE RAIL AND SECURE TO ANCHOR EYE WITH Ur DIAMETER THROUGHSOLT w MINIMUM4' TS CONTINUOUS BASE RAIL (SEE GROUND ANCHOR SCHEDULE, SHEET 1 OF 6. FOR REWIRED ANCHOR) CONTINUOUS 4' CONCRETE PAVEMENT EYE ANCHOR-­­�* � CONCRETE BASE RAIL ANCHORAGE Not To Scale (OPEN CARPORTS WHERESLAS EDGE DISTANCE DOES NOT MEET MINIMUM EDGE DISTANCE SHOWN IN DETAIL 113) TS TRUSSED RAFTER CHORD, / \ DR NONSTRUCTURAL HEADER _ \ TS END POST OR DOOR/ WINDOW FRAME POST > 2'x2W' 16 GAANGLE CLIP SECURE TO POST (EACH SIDE) TS BASENOINDOW RAILOR / WU AND RAFTERCHORD/LWITH NONSTRUCTURAL HEADER 2 GA IF ROLL -UP DOOR FRAME) / (4)412-14 x 3/4'SDFs,(2) ON TOP OR BOTTOM, (2) ON SIDE NOTE: AT ROLL -UP DOOR OPENINGS, POST SHOULD BE FLUSH WITH RAIL END. CLIP POST TO RAIL ONLY ON SIDE OPPOSITE THE OPENING. POST TO RAIL, TRUSS CHORD, OR ' NON-STRUCTURAL HEADER CONN. DETAIL 4 Not To Scale INSTALL 12' xMINIMUM S'TAPCONREDHEADLOT ANCHOR OR I2' x MINIMUM 5•I2' EXPANSION ANCHOR DRILL5/6'HOLETH THROUGH BASE RAIL WITHIN 6' OF EACH BASE RAILAND RAFTER POSTS ALONG SIDES AND EVERY END ANCHOR EYE WITH ID WALL POSTALONG END WALL SECTIONS THR 1. •' .. dr :.�� 1 CONTINUOUS 4' CONCRETE PAVEMENT ��CONCRETE BASE RAIL ANCHORAGE �B Not TO Scale (OPTIONAL -OPEN CARPORTS ONLY) 24. 16 GA UCHANNEL BRACE (S TOT POST) 46.16 GA U-CHANNEL BRACE (a TO W POST) BRACE ANGLE SHALL BE MIN. 45' TO MAX 60' FROM HORIZONTAL TS RAFTER 4 6' LONG TS NIPPLE SECURE POST TO NIPPLE WITH (4) 012-14 x 3/4' SDFs IV;Ia1taT11'1( %BOX EAVEIRA U IERIP,OSiT'DETAI E '��� Not toSWaT"`>•x -- "- TS RAFTER POST 1-12' x 1-17 x 2' 16 GA CUP ANGLE SECURE TO POSTAND BASE RAIL WITH (4) #12-14 x 3W SOFs, (2) ON TOP, (2) ON SIDE TS CONTINUOUS BASE RAIL END POST/BASE RAIL CONN. Not To Scale TOP OFASPHALT PAVEMENT rASHERS DRILL SIB' HOLE THROUGH THE 2' WASHERS BASE RAILAND SECURE TO TS CONTINUOUS ANCHOR EYE WITH Ur DIAMETER TS CONTINUOUS BASE RAIL THROUGWBWT BASE RAIL TOP OFASPHALT PAVEMENT OR STABLE GROUND SURFACE EYEANCHOR SIB' ROD 4W LONG WITH W HELD( OR SEE;GROUND ANCH.,_. SW ROD 6D' LONG G FE GULE SHEEP B, WITH THELLE FOR �PPI:iG1®ILiT1'jT"i AS APPLICABLE f �B7A'SE f2AIL�QEEP ANGI;IORAGE° _ z`'.-�..7 7NotTo Seal¢ NOSCREWS REQUIRED IN BOW BEND TS BOW RAFTER EYEANCHOR U (SEE GROUND ANCHOR SIB' ROD 3(' LONG SCHEDULE, SHEET 1 OF 6, WITH DBL 4'HELIXFOR APPLICABILITY) 24' 16 GA UCHANNEL BRACE IS TO T POST) 48' 16 GA UCHANNEL BRACE IS TO 14' POST) BRACE ANGLE SHALL BE MIN. 45' TO MAX 60' FROM HORIZONTAL NIPPLE TO BASE RAIL 3' t g G'LONG TS NIPPLE SECURE RAFTER AND POST TO NIPPLE WITH (4) 012-14 x 314' TS RAFTER POST SELF-DRIWNG FASTENERS BOW RAFTER/POST DETAIL Not To Sink POST 2' x 2' x 2' I6 GAANGLE CUP SECURE TO POST AND TOP OF HEADER, OR BOTTOM OF WINDOW RAIUGIRT WITH (4) 012.14 x 3W SDFs (2) ON TOP OR BOTTOM, (2) ON SIDE NONSTRUCTURAL HEADER TS WINDOW RAIL OR GIRT FOR VERTICAL SIDING OPTION NON-STRUCTURAL HEADER, WINDOW ,'-�RAIL, OR GIRT TO POST CONN. DETAIL Not To Scale 8BASE RAIL ANCHORAGE t� Not3o Saale - 6' LONG TS NIPPLE SECURE POST TO NIPPLE WITH (4) #12-14 x 3W SDPs RAFTER POST CONTINUOUS BASE RAIL r.� �POST/BASE RAIL CONN. DETAIL � Not TO Smle ING j'� .• LICFNS y i i NO 38538 '•O - .Qop <pRIDA lG�� 0 A.E4­?0``�. CAROLINA CARPORTS, INC. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA awaa�A°rc"o'a�c"«`cLL rxwawOr....w w•ew w..ti ruw.00 — 7115119 BECNTOL ENGINEERING R NTS AND TESTING, 1. R G79001ro"B SHEET OF C TS END P( Not To Scale 2Y2'42' 16 GAANGLE CLIP SECURE TO POSTAND RAFTER WITH (4)012-14 x 3V SDFS, (2) ON BOTTOM, (2) ON SIDE OR 2' 4' 16 GA PLATE SECURE TO EACH SIDE OF POSTIRAFTER CONNECTION WITH (4) #12-14 x 3/4'-SDFs,- (2) ON POST, (2) ON RAFTER CONN. DETAIL CLIP ANGLE SECURE TO RAFTER POSTAND GABLE RAIL WITH (4) #12-14 s 3V' SDF's (2) ON TOP, (2) ON SIDE TS GA ' 16 GA CUP TO RAFTER . WITH (4) -6. (2) ON TOP, RAIL \ GABLE RAIL TO RAFTER POST CONNECTION DETAIL "^ Naresa�e 2-1/4' FOR 12 GA FRAMING 2.12' FOR 16 GAUGE U-CHANNEL BRACE FASTENED TO THE POST AND RAFTER WITH (2) #12-14 x 314' SDFS AT EACH END (4 PER BRACE) — BRACE SECTION I" To Sale NIPPLE DBL. HD LONG TS NIPPLE :CURE EACH WITH 1 #12-14 x 3/4' R.F-DRILLING FASTENERS --12 GA TS POST ��RAFTER POST/DBL. HEADER DETAIL a Nol To Sale - 1-1/2' x 1.12' x 2' 16 GA CUP ANGLE SECURE TO RAFTER POST AND GABLE RAIL WITH (4) 012-14 x 3/4' BE TOP AND BOTTOM i 1-12' x 1-1?x 2' 16 GA CUP ANGLE . SECURE TO RAFTER AND GABLE RAIL WITH (4) #12-14 x 3/4-SDPs, (2) ON TOP; (2) ON BOTTOM 11B NvtTo6tslo. S' LONG TS NIPPLE SECURE RAFTER AND POST TO NIPPLE WITH (4) 012-14 x 314- SELF-DRILLING FASTENERS 1 RAFTER POST RAIL TO RAFTER POST CTION DETAIL YIhKFUiI 4G IS NIPPLE RE WITH (4) 412-14 x3/4' DRILLINGFASTENERS DOUBLE TS HEADER NIPPLETO DBL HDR. RAFTER POST/HEADER DETAIL Not To Scale RAFTER 12'LONGTS NIPPLE. SECURE POST TO NIPPLE WITH (4) #12-14 x 3/4' SDFs. ' 24. 16 GA U•CHANNEL BRACE (S TO T POST) 46' 16 GA U-CHANNEL BRACE IS TO W POST) RAIL- BRACE ANGLE SHALL BE MIN. 4S' TO MAX 60' FROM HORIZONTAL G'LONG TS NIPPLE SECURE WITH (4) #12-14 x 3/4' SDF's RAFTER POST SIDE EXTENSION RAFTER/POST DETAIL Nare sm. TS LEG POST TS LEG POST 1-12' 1S GAUGE FURRING CHANNEL FASTENED ITS TO EACH RAFTER WITH (2) #12.14 x 3r4' SDF TS RAILS POSTS SPACED NOT MORE THAN 48. O.C. / \ 26 GA. METAL ROOF PANEL ROOF PANEL ATTACHMENT (ALTERNATE FOR VERTICAL ROOF PANELS) Not To Scale B' -- r-0' I — TYPICAL FLOOD VENT FRAMING PLAN NOT TO SCALE 1' SEE GENERAL NOTE No. 12, SHEET 1 OF 6. 6' LONG TS NIPPLE SECURE EACH WITH (4) 012-14 x 3/4' SELF-DRILUNG FASTENERS POST RAFTER POST/BASE BASE RAIL CONNECTION DETAIL Iv NW To Scale TS RAFTER POST 2-0' 16 GA PLATE (ONE REQUIRED) SECURE TO EITHERSIDE OF POSTIRAFTER CONNECTION WITH (4) 012-14 x 3/4' SDFs, (2) ON POST, (2) ON RAFTER ITS LEAN-TO RAFTER 272Nr 16 GAANGLE CUP SECURETOPOSTAND RAFTER WITH (4) IM2-14 x 3/4' SOPS. (2) ON RAFTER, (2) ON POST I" POST/LEAN-TO RAFTER CONN. DETAIL TNe BECHTOL DELAND, FLORIDA 2320 •9� —C •.7' CerOfiate of N = 92: r�3g538 C' _ F mds S TAI— IDA CAROLINA CARPORTS, INC. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA °" 7/1S/I9 BECHTOL ENGINEERING RR NTS RR G19001 AND TESTING, /..�. ma rvno..c.� uonoo..r.�.m,,.n�,.,mw cramTS sHEErsoF6 VERTICAL SIDE OPTION GIRTS (TrPk01) SEE TABLE 1 OPENING FOR SWINGING DOOR SHEET TWI TH NONSTRUCTURAL HEADER 17 MA1L OPETNG FOR RM-UP DOOR WIIII TYPICAL END WALL OPENINGS POST/RAFfER/GIRT FRAMING PLAN NOT TO SCALE BOX EAVE FRAME RAFTER ENCLOSED BLDG - VERTICAL SIDES ROLL -UP DOOR SWINGING DOOR TYPICAL SIDE ELEVATION NOT TO SCALE TYPICAL END ELEVATION NOT TO SCALE GRTS (T7P-U 1-1? 18 GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER NTH (2) #12-14 x 314-SELF-DRIWNG 8•—I I— / FASTENER SPACED NOT MORE THAN 48. O.C. OPENING FOR SWINGING DOOR WI TH NONSTRUCTURAL HEADER TYPICAL POST/RAFfER/GIRT FRAMING PLAN - NOTTOSCALE BOX EAVE FRAME RAFTER UTILITY BLDG - VERTICAL SIDES TYPICAL SIDE ELEVATION TYPICAL END ELEVATION NOTTOSCALE. NOT TO SCALE mb orOwAuWpAi Ceei> on-PJo 92� �� •`ram 3 539 — ST .CAROLINA CARPORTS, INC. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA rrd ° 7115/19 BECNTOL ENGINEERING RR Nrs AND TESDNG, /nc �nmcumrn.rxw.ul.rnr.�r..n..+uwanamaurnvw um® RR "'' G19001 TB SHEET6OF6