Loading...
HomeMy WebLinkAboutPURCHASE AGREEMENTPeace of Mind Purchase Agreement Pg 2. Between USGenerator and VQ_ TO Str Pd ZO The purchaser understands that USGenerator, Inc. is a licensed natural.gas and propane°generator specialty installer and electrical contractor and wilMe scheduling the various -phases of the system:_ integration. A 50% non-refundable down payment is required -upon signing -this -agreement. An addi= tional 30% is due upon delivery of the generator to the job site. The balance plus cost of all feesiis due immediately upon your generator passing inspection from the building department. These pay= ment schedules may be amended by letter of agreement for builders. Thisorice does not.in-. the fuehsuaalier•oFtheir choice but USGenerator will coordinate the combined installation of these -components and you will be billed by your fuel supplier. Your initial deposit is fully' refundable for the following reasons:'1.) Homeowners association or property management;.if appilicatile, will not approve the installation, such approvals will be the customer's responsibility to obtain prior to commencing work 2.) If site will not qualify for a generator orpropane tank; permlt.-You agree;#o help keeptUSGenerat6rJnc.:inf6rm6d`by.phon,e if you experience late or=non-arrival'ofscheduled personnel::You,understand that unless ACHA approved, this generator is not life support rated. If you have a'medical.condition that will immediately threaten your life in the event of an electrical' povi b faildre. additional hardware will be required-an1s.not included in this system. The ptiirchase personally guarantees its performance under this agreerrientand in the event of a dispute; agrees-1 resolution by binding arbitration under the rules -of the ,commercial division of the Arnerican•Arbitra= tion Association. (Personal guarantees are waived for builders.) The prevailing'party _shall be=en titled to its reasonable legal -fees and the' cost of the arbitrator, if used,, including travel expenses. Any dlspute resolutlon,shall be3conductetl in Vero Beach, Florida. In -the event of a manned couple,. eltherprty.may`sign his agreement, but agrees'that the personal guaranteeshall apply_to both persons. You funherunderstand that refusin4 deliverer or failinv to make the scheduled payments Payments Vou have already made. If reppssessiom is necessary, you hereby;grant permission:for'' . USGenerator to enter tFie Job site and remove the generator. This is the con5plete agreemendbe-"' tween the parties and -no changes are implied or permitted unless e both agree'in-writing.. We' hereby acknowledge receipt of the initial -down payment of: $ s 0 O Hold deposit check Until -notified USGenerator, Inc./ �n Authorised Representative/se�nttta-tiivee OS-30-18 Agreed: SCANNED Cust r. BY St. Lucie County General information on Fuel System Costs 1. Propane tanks: 500 gallon tank— $ 3500-5500 buried, filled with fuel, permits, and lines run and hooked up to the generator, leak tested. Tanks can be leased"* or purchased. Long dis- tances from the generator will incur additional charges per foot, usually $ 10-15 per ft. 2. Propane tank: 1000 gallons: $ 4200-6200 3. Propane tank: 250 gallons $ 2500-3500 (not recommended for 22 kW & above) 4. Natural gas: Price,depends on distance pipe must be run. Typical prices are $ 750-1400 un- less meter must be changed out. 5. Diesel: You will be charged by the gallon delivered to the jobsite at current diesel at the pump pg2of2 5 [ Z8 / Ze EC-IliO06427' 620565tMStreet Vero Beach, FL 32967 772-778-0131 1 561-889-0035 West Palm Beach 1772-794-2439 Fax I E-mail USGen(dlcomcast.net Peace of Mind Purchase Agreement 3jg86 017 1. Delivery of the generator to the job site & cost of heavy crane or other specialized equipment, if required. 2.__Preparing_the-site.and-placing the.generator.__- 3. A 4000 psi concrete/fiberglass reinforced hurricane pad according to manufacturer's specifications, 4. Generator and transfer switch integrated with the electrical system according to all applicable building codes. 5. Mounting the automatic transfer switch with built in emergency load center or direct feed to existing house panel on a customer approved locationwhich complies with all codes and nd cleanup of jobsite. - -6. Transfer switch &,pane : (circle/underline2)' ele 7ex /house tran r or partial.panel dransfer. li- 16CB Load center O:am Nexus: 3 ,amp Nexus 400 amp p exus PMMs #_ 7. ) 8. Application of'extemaland internalcorrosion prevention product 9. Customer training, presentation offactory manual, maintenance log including warranty information willbe ' scheduled:at your convenience within'30 days of your final payment i 10 'Five4�6jyear limited warranty on liquid cooled and air cooled engine, generators. 11. Since permitting fees vary among governing bodies, the cost for permits, elevation certificates, notices of commence ment, insurance.assignment fees and HOA/county/city processing fees will be added to the, final, payment.-Administra• tive and inspection fees range betwe 0, permit fees range are $ 75.00-$ 325.00 and elevation: certificate: are $ 175.00 if site is in i floodpl ' . Large HOA dep will bethe 'customer's responsibility: 12. Completion time is approxima 0-180 days a we receive the permit from building departments. Thi: could be significantly shorter or onger caused by variables beyond- our control such as,, but not limits to factory backlog, fuel type, availability of critical components, delays in installations -scheduled ahRl' o 13. Customers desiring to leave town before the installation is fi and provide an available representative to complete the job. Base price.- $ 9 600 additional cost for non -stand Number of switches ( i ) Total cost for switches $ ( "ZVo,") Additional cable'& trenching for 14-22 kW over 10Ft—$ 39.00 Ft/ $49.00 Ft for 27 kW and for 36-48 kW & larger' ($ 59 ft) $ Flood compliant pad $125 per inch over 4 inches $ Power Management Module: for Nexus switch: (Z)�@ $ 199 OO each, $ t7 O Hardaart k\s (--� @ $ 185.00 each $' _Options • :Permits, fees; CAD:drawings.and fuel system not included. Credits: For: Optional Eouipment & Services: - i New Generator Service Plan $� ..00 (Minimum required to maintain warranty) Optima Spiral' Cell Sealed AGM Battery $ 449.95 (48 month warranty) Correcting mislabeled electrical.panels: $ 75.00 hr. Generator compatible whole house surge protector $ 525.00 (Installations using,2 transfer switches require 2 surge protectors.) S14^%Generaaextended factory warranty. (-7years-$7Q5 11years 5t95}- Total Optional Equipment &,Services: $ f permits, administration fees, notices of commencement, CAD drawing fees, removing,and-rein- I systems up to,code, paver removaland reinstallation, or correcting mislabeled panels. Note., Lucy will Incur a $350:OO surcharge that will be added ito permit fees duetothe complexity of Rev 6-13-18 Page 1 Of 2