Loading...
HomeMy WebLinkAboutBUILDING PLANS�{IRsc t� ,.�`�7►_,�,8Ft�G72�PI: tea, _ Fr P��2crr EL i SCANNED BY St. Lucie County 3 00 i UO YEON KIM, P.E. FL -A. LIC. NUMBER 49497 CA. ; 87 UO KIM 8& S OC., LLC P.O. B 10039 TAMPA 379 36 ' (813) 9ss q,zvi4 m Rw9Fr7-D AOOF� CRss,tiENGa7 � � - 3Ta�cr' jTwm I 'xx3 N 0 �p, o xr� 2x3 HZI it 3' x 3' x 0A50- NIN.,6063-T6 ALLOY PLATE DR STRGNGERAGNE SIDE) WITH (3) - 412 x %' SAS, EACH SIDE AS SHOWN (%• MIN. PLATE EDGE DISTANCE L C-C FASTENER/SPACING) R, 110.050- MIN. 6063-TG _ATE OR STRONGER ) SH.S, E AS SHOWN PLATE EDGE 6 C-C (11 TOTAL) - 412 SAS AS SHOWN ( PATIO SECTION PLATE EDGE DIST C-C FASTENER 9 e 6- x 5' x 045G' e 6063-Tfi ALLOY PLATE e °o p (ONE SI➢E) OR STRONGER K-BRACE 2.3.0.070 CHAIR RNL K-BRACE K-BRACE CORNER POST- V x 2- EOLE PLATE ANCHOR <2 PLACES) W 0 CONCRETE HER COLUMN LMICFWL IN -I CONNECTION Ix2 O.B. ATTACHED i0.8FAM W/ (2)-(f 0%2' S.M.S.•INTO SCREW BOSS THRU-BOLT W/ Y4 -'NUT AND WASHER EACH SIDE OF BEAM Ix5%Y' ANGLE 6' LONG (TYP. @EACH BEAM) (2> y"0x3' LG. @EACH ANGLE NO p 2x2" S.M.S. ®24" O.G IY1 O.B. TO SUPER CUTTER FACIA TO BE 2z6 WINJ SPF OR WESTER RED CEDAR STRUCTURAL GRADE 2 MIN. ( 4) 812x3/4" S.M.S. (1) Yi 0x2- LG. LAG SCREW @ 24- U.B. ENTIRE LENGTH OF GUTTER R OF BRA ( TOR SLOPED) SECURE FASCIA TO EACH RAFTER TAIL V/ (1) Y-0x4" LONG PAN HEAD LAG SCREWS IBEFORE ATTACHING SUPER GUTTER O ® 0 0 _ 0 GIRT (CHAIR RAIL) (1) Y-0x2- LG. LAG SCREWS C ❑ F] 1 (TYP. @ EACH BEAM) (4) 112x3/4' S.M.S. (D x12.2' SAS @ 12' u.o EAGH LEGm (MAX) BETWEEN BEAMS W/(2) R.- THICK CONTINUOUS 5' or 7' SUPER GUTTER ANGLE MIX G090' THICK SECURE FASCIA TO EACH RAFTER TAIL 810x3/4' 0 2' O.C. BEAR OF tC BEgM`STITCHING SCREWS (SEE TABLzz E l,I� L�-tom SPLICE PLATE (EACH SIDE OF BEAM) D O K I M SPACE SCREWS A A 5052-H32 ALLOY OR EQUAL, 1/B' THICKNESS EQUAL (TYP.) f.. _ & ASSOCIATES, LLC f CONSULTING A �IL 31 STRUCTURAL ENGINEERS 2J PO Box 10039 Tampa, FL 33679 1 X ItHP' p14x�' SCREWS j Tel:(813) 374-0321 J� REAM LINE LINE SCREWS PLATE 'pR (1yp0 A4''(k 1 RevJDat Description g r', BS U'B'6'C' TOTAL WIDTH ZR G f00. -9 2x4 3 2 24 12- 0 2016 ISSUED Ova 10 2x5 3 3 32 14' 2x6 4_ 3 40 14- 0 ,}.N, @�� WAD _5... 64 _,16� 1-14' BY 2" LONG -A ANGLE, EACH SIDE (TYPJ (4) B14x1$' S.M.S 2 SCREWS EACH lED (TYP.) HOLLOW POST REI CHAT C — � 2x PURLIN (MAY BE SLOPED OR FLAT) \_ MANSARD BEAM 2x9 5 6 72 Is, 0 2x9(HW) 6 7 e8 18. CONNECTION DETAIL 2x10 7 7 96 IBA - Q REVIEWMIFOR-._ CODENM. 1 1/� c COUNTY ST. LUCIE COUN li u (4) JIOaJ" LONG S.M.S. INTO (6) /12xvm S.M.S., EACH EEC AND SCREW BOSSES (TYP. ALTERNATIVE) (9) SCREW TOTAL CHANNEL TO BAM I6I��_ B OCC a 24' O.G. BEAM STITTOP AND TOP ANO BOTTOM OF SMB FO L3�O.OTO SEE TABLE FOR SIZE) SEE -I Q W 2x3xO.07U dRT/CHARL�� t /� 0of (SEE PLAN) U 1 BRAKE -FORM R N ANND lxlr]g' BY 3' LONG ANGLE, EACH 510E (TYP.) rn O,_J _ (MIN. 0.062' MATERIAL THICKNESS) 1' x 2 1/a" x 1' x 3' LC. (3) ®12Y.Tj $A1./5�., EACH CD Acaaa ATNE) LEG (6) TOTAL ( .) L. U Z T MIN. (4) #lU2" LONG S.MS. INTO SCREW BOSSES �}� SCANNED L W Z • i_, (TYP. ALTERNATIVE) l-!� t - BY N W ..-''S.M.B. POST St. Lucie County '0_o (as PURLIN TO ROOF BEAM a FILE �� CONNECTION DETAIL W a (A Z41L / GIRT TO POST U III NECTIONIDETAIL DRAWN BY; c BxFAM54WOH 3RA1IOx2'ASM.B.CKED INTO SCREW BOSS �T TO^�� i + B.M.B. REAM MAY�BE�SLOPED OR MT (SEE PiA ,FOR SIZE) CHECKED BY: E SCALE: P DATE: 8 WITH - - n (2)-A14x1� .� IS. a 24' O.C. - - —L •.2.(/ s 1.2 O.B. TO 2x3. i-(( -w I USE�s1Oxl)4' S.NS. a 24- O.C. - - _ - - TOCONNECTTO tx2 O.B. TO 2.3. COLUMN/POST ii6Y) O DO SCREW BOSSES PURUN FASTENED TO COLUMN/POST WITH (4) N12x1- S.M.S. (EACH LEG) .(9) /12.Y- S.M.S. EACH SIDE 'a (EACH END. TYP.) USING )6' THICK FLAT BAR BENT OF BEAN OR ') MIN, 3 1¢' MAX. C-L TO FB (G 63-T6 ALLOY) S.M.S.Me' SIDE 'OF EAM F25. COLUMN OF. BEAM FOR 2x5 COLUMN TO SPACING OF FASTENERS (TYP.) 2i5'BEAN Y' MIN, BEAM EDGE COLUMN/POSF DISTANCE (TYP.) COLUMN/POST DO YEON KIM, P.E. FLA REG. NUMBER 49497 DO KIM AS IATES, LLC A# 26 7 P At 1 039 Tam ,F 9 ovwgl Drawing No. - 060811 SHEET 1 OF 3' SEE 1.2 D.E. FAS SECTION WITH 24' O.C. .J W/ • T y'Ra2v- CONCRETE i� SCREW ANCHOR O 24•I0. �¢� AND 9' MOM POST (TYP; N W TI y. COIuuN/PUST fat O.B. SOLE PLATE I E CONCRETESI•(TYP.) N� PLAN VIEW PUMUN SUPPORT COWMN/POST /•� 4].10 Lf,179 B.M.$ `►• N SIOE) O O %'0 CONCRETE ANCHOR e -d w/236• I]IBFDMENT INTO STRU RAL CONCRETE (EACH SIDE) 'LWFOR SIZE 114xIED TO CORNER d l4xly' S.M.SO 2• LONG (EACH SIDE) w Wjy yANG CONIC CFI SINE (OR S.M.S. WITH MIN.' x EDGE OOTANCE W/2 ' EMBEDMENT, INTO STRUCTURAL. RAL. COEM.IMO SME NOTE GONCRETE (T1 /'•$EE NONE 10) —1(J 1'x2' O.B. 90LE.PL 4C./A )§' ANGLE. EACH SIDE (OR W/2 CONCRETE ANCHOR W/2)(t' EMBEDMENT CONCR CONCRETE SEE KOMAL CONCRETE (IYP., SEE NOTE 10) �1'IQ' O.B. SOLE PLATE aW 3• MIN. (TYP.) yrcr yaaY4• CONCRETE tub SCREW ANCHOR a 24' O.C. AND 9' MOM POST (TTPJ t¢� 9. wwmn/rwl 1.2 O.B. SOLE PLATE 0 0 B— 0 e OF CONCRETE NV i/ PLAN VIEW PURUN BEAM MAY BE MT OR SLOPE, A BEAM WITH ONE (1) X BOLT, WITH FENDER W ATTACHED TO BEAN 01 DIAGONAL BRACING SR ATTACHED TO ROOF PI 2.2.0.093 BRACE (SEE FUN) 2x5x16' ANGLE (2' LONG) V/ (2)-914 TEKS INTO TOP OF 2x3 CAVE RAIL AID) (2)- 614 TEKS INTO THE FRONT OF THE GOOIER POST I-fx2 O.B. TOP FRAME 1x3 O.B. FASIENEO TO CORNER CORNER POST SECTION WITH IIOx2• S.N.S. W/ OF III' DIA WASHER O 18' O.C. I- 1a O.B. SIDE WALL CORNER UPRIGHT RNL BE ELEVATION VIEW CORNER POST/COLUMN UPRIGHT DETAIL PSI MIN. CONCRETE STRENGTH DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 ISSUED Cn J COMPACTED OR UNDISTURBED SOIL/SAND = W II J(1)-9 REBAR, CONTINUOUS O f ' ' • i. • •' ia�, I �Ir- I—�I I ��� 3' MIN. CONC. COVER, 36' MIN. C W . • '4 • ,Of �.. ...4.. I-r I I — I ,-I, 1— LAP SPLICE U TA 4 C 0 y 0x5T CONCRETE SCREWS a 24' O.C. �2%- MIN. CONIC. BEM, SUPPORT i 12' MIN. U COLUMN/POST >• (TiP.). lY2' CONIC. EMBEDMENT (MIN.) EMBEDMENT (TYP.) Z W W/ (4)e• = 2' LG..M.S )I MIN. CONTINUOUS PERIMETER FOOTING w W/ (4) /12x3/4' S.M.S (EACH SIDE) '' TYPICAL FRONT VIEW OF POST TO LU FOUNDATION CONNECTION WITH PAVERS c Z K REVIEWED FOR a CODE COMPLIAN51._ z C) 0 PNST� BEve ALTERNATE (11 1 W !L ST• LUCIE COUNU c 2.IA' ANGLE U / (4) S12xy' S.M. BRACE DRAWN BY: C 4' NOMINAL. CONCRETE SLAB BOCC 2'a PURUN 2'xl'ry ANGLE (BRACE) W CHECKED BY: C ^' (2500 PSI MIN / COLUMN e e . APPROXIMATE MAN. THICK BRICK PAVERS GTER ' IN MORTAR ON TOP OF GO F • I d' O O.B. SOLE PUT, a N- d� d. , ,. W.W.M. OR FIBER REINFORCED (4) #12rY4' S.M.S. O EACH [POLYPROPYLENE ROM - MEMBER INTERSECTION 1.5 POUND (MIN.)PER C.Y.) e o z e •4 a ANGLE 2' LONG ON UNDM +1 RE • e . BEAM MAY EACH LIG (BEAM EACH LEG (BEAN h BRACE) ) < ' ` • • e' BE FIAT ` OR SLOPED 4 e.. •aa. 4 �4EACH B a Y• .. a NO) Lu1 BRACE (SEE PLAN) EACH END) ' • A ALTERNATE 121 xd' • e <A \\\ 2x3 BRACE - `UNDISNRBm SOIL OR COMPACTED HED CAR CON IUOUS. LICE P�'p1 MIN. (OVERL ROAR CONTINUOUS, SPLICE L MUST ovEmnP 20' MIN. Qti COP b' PLAN -TYPICAL ROOF e•cwN) s' COVER c".) BRACE TO BEAM CONNECTION 1 FOUNDATION/SLAB DETAIL DO YEON KIM, P.E. FLA REG. NUMBER 49497 DO KI v1e..;60039 CIATES, LLC 7 AS Tampa, FL 33679 Rvwt4 Drawing No. - 060811 SHEET 2OF3 I REVIEWEt') RDH CODE OOP rf'LIANCE ST. LUCIE OOU#,4 g y ROOC Genera( Notes and Specifications: 1. Contractor shall field verify all dimensions before construction and shall notify engineer of discrepancies for immediate consideration. 2. Concrete shall be minimum 28 day compressive strength of f'c=2500 psi, and be in accordance with the requirements of ACI 318. Reinforcing steel shall have a min. yield strength of 40,000 psi (grade 40) and be provided with cover in accordance with ACI 318. 3. All dimensions are provided by contractor, DO Kim & Associates, LLC have made interpretations where necessary. 4. The following structures are designed to be attached to block and wood frame structures of adequate structural capacity. The contractor shall verify that the host structure is in good condition and of sufficient strength to hold the proposed addition. If there is a question about the host structure, the owner (at his own expense) shall hire an architect or engineer to verify host structure capacity. S. Screen density shall be a maximum of 18 x 14 x 0.013" mesh. Aluminum shall be 7005453 Alloy. 6005-T5 Alloy; for secondary components 6063-T6, Alloy based on industry standard shapes, thicknesses, and tolerances unless otherwise noted. 6. Unless otherwise noted. SMB shall be stitched with #100/4" SMS at 24"o.c., top and bottom. 7. Connections using screw bosses shall have minimum (41410x2" per connection unless shown otherwise. 8. Unless otherwise shown, screws shall have minimum edge distance and center -to -center distances as shown in this table. 1-1022 Low Carbon Steel SMS & Self -Drilling (TEK) Screws (Industry Standard Screws) Screw Nominal Screw Diameter (in) Minimum Edge Distance Minimum Center to Center Distance #10 0.188 #12 0.219 #14 (1/4") 0.250 112" 9. Structure has been designed to meet the 611 Edition FBC (2017 FBC). Project is sited where the ultimate design wind speed, Vdi, is 150 mph 13-sec gust) for risk category I buildings and other structures. Exposure B. Design pressures are from Table 2002.4, 2017 FBC reduced by 0.88 for screen mesh factor, 0.6 for allowable stress design (ASCII. 10. Concrete anchors may be "Large Diameter Tapcons" (LTDs), Tapcon concrete screws, Simpson Strong -Tie Anchors or Titian Screws or approved equal. 11. Screen enclosure structure shall meet Section 454.2.17 Residential Swimming Barrier Requirements and the screen enclosure per 454.2.17.1.11. if enclosing a pool. D❑ KIM & ASSOCIATES, LLD CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 ISSUED J H w U 0 w 0 � O U Z w z c O U 'a F W LU a U O DO YEON KIM, P.E. FL0. REG. NUMBER 49497 D KI 8 SOCIATES, LLC A# 28887 9 Ta a, FL 33679 cl, a-m Drawing No. - 060811 1 SHEET 3OF3