FLORIDA ENERGY EFFICIENCY CODE FOR B DING CONSTRUCTION
Florida Department of Business and Professional Regulation -�s d ntiert {y�
Project Name: SHOWEN RESIDENCE
Builder Name: TC CUSTOM HOMES
street SILVER OAK
Permit Office: CITYOF PORT STLUCIE
City, State, Zip: PORTST LUCIE , FL,
Permit Number.
Owner: i
Jurisdiction:
Design Location: FL, Fort Pierce
County.: St. Lucie (Florida Climate Zane 2 )
1, New construction or e>osUng New (From Plans)
9. Wail Types(2038.0 sgft)
Insulation. Area
2. Single family or mulliplefemHy Single-family
a. Concrete Block - E)d lnsui, F)derio
R=4.1 2038.00 ft-
3. Number of units, If multiplefamlly 1
b. NIA
c MIA
R= ftz
R= ftz
4. Number of Bedrooms j 3
tl. WA
R= h,
5. Is this a worst case? i No
10. Ceiling Types (1725.0 sgft)
Insulation Area
6. Conditioned floe area above grade (W) 1725
a. UnderAttip(Vented)
R=30.0 1725.00 ft=
b. NIA
R= ftz
Conditioned floor area below (f 2) 0
c. WA
R= ftz
grads
7. Windows(267.0 sgft) Description Area
11. Ducts
a. Sup: Attic, Ret Attic, AH:Attic
ft-
6 1500
a. U-Facto: Sgl, U=0.32 152.00W
SHGC: SHGC=0.19
b. U-Factor: Bill, U=0,32 88.00 ftz
12. Cooling systems
kBtulhr Efficiency
SHGC: SHGC=0.22
a. Central Unit
36:0 SEER:16.00
c. U-Factor. 591, U=0.28 27.00 W
SHGC: SHGC=0.21
13. Healing systems
kBkVhr Efficiency
d. U-Facto: NIA fit
a. Electric Strip. Heat
27.0 COR1.00
SHGC:
Area Weighted Average Overhang Depth: 1.000 R
Area Weighted Average SHGC: 0102
14. Hot water systems
8. Floor Types (1724.0 sgft) Insulation Area
a. Electric
Cap: 50 gallons
s. Slab -On -Grade Edge Insulation R=0:0 1724.00 ft-
bConservation features
ER 0.980
b. WA R= ft'
.
None
c. NIA R= ftz
15. Credits
None
{ Total Proposed Modified Loads: 60.81
Glass/Floor Area: 0.15,5
PAS` S
Total Baseline Loads: 66:91
i
I hereby certify that the plans and specifications covered by
Review of the plans and
SP,gpB
this calculation are in compliance with the Florida Energy
gpecifications,covered by this
Q4HE
p
Code.10
calculation Indicates compliance
yv''. _� spa {
r
with the Florida Energy Code:
PREPA ED BY:
Before construction is completed
d°
DATE: -
this building will be inspected for
f
`� F. j
i
compliance with Section 553.908
1 hereby certify that this wilding as des n in compliance
Florida Statutes.
,
with the Florida one g C: e_
C0D
WEli _
OWNER/AGENT.
LDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist inaccordance with R462A.1.1 and this project requires
an envelope leakage test report with envelopeleakage no greater than.7.00 ACH50 (R402A.1.2).
t
I
5/21/2018 4:05 PM i EnergyGaugeQ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6
u
PROJECT
Title: SHOWEN RESIDENCE
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1725
Lot#
Owner Name:
Total Stories: 1
BlooWSubdivision:
#ofUnits: 1
Worst Case: No
PlatElook:
Builder Name: TO CUSTOM HOMES
Rotate Angie: 0
Street
SILVER OAK
Permit Office: CITY OF PORT ST LUCIE
Cross Ventilation; No
County:
SL Lucie
Jurisdiction:
Family Type: Single-family
Whole House Fan: No
City, State, Zip:
PORT ST LUCIE,
New/Edsting: New (From Plans)
FL.
- —.Comment —--
--
-
-- - -
_
j
CLIMATE
-
Design
Design Temp
Int Design Temp
-Heating
Design
'DailyTemp
Location
TMY Site
97.5'/>'
2.5%
Winter
Summer
Degree. Days Moisture
Range
FL, Fort Pierce! FL VERO_BEACH MUNI 30
I;
90
70
75
299
62
LOW
BLOCKS
Number Name _
Area
Volume
1 EntireHwrse
1725
17350
ISPACES
Number Name. i
Area
Volume Kitchen Occupants
Bedrooms
Infil ID
Finished 'Cooled
Heated'
1 M BATH j1
152
1520 .No
0
1
Yes
Yes.
Yes
2 MWIC `
47
470 No
0
1
Yes
Yes
Yes
3 MASTER BEDROO
240
24DO No
0
1
1
Yes
Yes
Yes
4 FAMILY ROOM
230
2300 No
0
1
Yes
Yes
yes
5 DINING i
120
1200 No
0
1
yes
yes
yes
6 FOYER (
100
1100 No.
0
1'
yes
Yes
Yes
7 KITCHEN i
194
1940 Yes.
0
1
Yes
Yes
Yes "
8 CLST 2
i
26
260 No
0
1
Yes
Yes
Yes
9 BEDROOM 2
166
1660 No
0
1
1
yes
yes
yes
10 BATH 2 I
45
450 No
0
1
Yes
Yes
Yes
41 BEDROOM;3
145.
1450 No
0
1
1
yes
yes
yes
12 CLST 3 4
18
18D No
0
1
Yes
Yes
Yes
13 LAUNDRY I11
54
540 No
0
1
yes
yes
Yes
14 HALL
72
720 No
0
1
Yes
Yes
Yes
15 NOOK
116
1160 No
0
1
Yes'.
Yes
Yes
FLOORS77�
-
# Floor Type
..Space
Perimeter 'Perimeter R-Value.
Area
Joist R-Value
Tile. Wood
Carpet
1 Sleb-On-Grade
j Edge Insulation
M BATH 28.8 ft 0
152 ft-
_
1 0
0
2Slati On -Grade
Edge Insulation
i
MWIC 1 ft 0
47 ft-
] 0
0
3 Slab -On -Grade Edge
Insulation
i
A
MASTER
BEDRO 31it 0
-240'IF
__
1 0
0
5121120184:05 P.M
41 EnergyGaugee USA- FlaRes2017 Section R405.4.1 Compliant Software
I
Page 2of6
FORUR405-2017
}
FLOORS
# Floor Type Space Perimeter Perimeter R-Valua
_ Area
Joist R-Value
Tile
Wood
Carpet
_
4 Slab -On Gratle Edge Insulation FAMILY ROOM 14 It
0
230 f?
1
0
0
581ab-On-Grad= Edge Insulation DINING 16 ft
0
1201t'
1
0
0
r
6 SiataOn-Grade Etlge Insulation FOYER loft
7SIab-On-Gred E Edge Insulation
0
100 ft'
1
D
0
KITCHEN 8ft
0
194 ft-
1
0
0
,_
6SIab=On-Gra e EdC
ge Insulation LST 2 1 It
0
26 TN
.�
9 Slab-On•Gmde Edge Insulation BEDROOM 2 26 ft
0
ft-
166
.r
1
0
0
IOSIat On -Grade Edge Insulation
—
BATH 5ft
I
0
45 ft-
M
Y
0
0
_.
11Slab-On-Gmd
0i}}(((Edge Insulation BEDROOM 3 26 it
0
144.5fi'
1
0
0
12SIab-On Gm JEdge Insulation CLST 3 2 ft
S£Edge
0
18 fN
._
1
0
0
1381ab-On-Grad Insulation LAUNDRY loft
0
54 fN
14SIab-On-Graillird9e Insulation
1
0
0
HALL tft
I
0
71.5 ft'
1
0
0
15SIab-On-Grade Edge Insulation NOOK 26.6ft
p
tlgg*:
R
1
D
0
r
ROOF
Roof'.
# Type
Gable
Roof
.Solar , .
SA Emitt
'Emitt
Deck
,Pitch..'
Materials, Area
Area
Color
Absor.
Tested _
Tested InsW.
(deg)
1 Hip Composition shingles, 1868.ft
0 fP Medium.
0.6
No 0.9
No
0
22.8
ATTIC
in)
_
# Type . Ventilation Vent Ratio (I
Area RBS IRCC'.._
I Full attic �. Vented
150
1725dt- N
N
CEILING
`
# Ceiling T `..
1 •under Attie
R-Value
..Ins Type Area
Framing I = 'Truss Type.
_
(Vented) MSATH
30
Blown
152 ft-
0:1
'Wood
2 UnderAttiI (Vented) MWIC
30.
Blown
47 ft?
0.1
Wood
3 , Under Attic (Vented) MASTER BEDRO
30
Blown
240 ft-
0.1.
Wood-
_
4 UnderAtfic(Vented) FAMILY ROOM,
30
'Blown
23011'
01
Wood
5 UnderA8lc.(Vented) DINING
30
.Blown
120 fP
01
6 UnderAttic(Vented) FOYER
30.
:Blown
- 100ft'
-0.1
Wood
Wood
7 Under Attic(Vented). KITCHEN
30
-Blown
194ft'
0.1
Wood
8 Under Attic (Vented) CLST2
30
Bloom
26 ft
0.1
Wood
9 Under Atlio(Vented) BEDROOM
30
Blown
166 ft'
0.1Wood
_.
10 Under Attic (Vented) BATH
30
Blown
45ft
0.1
Wood
11 UnderAltic(Vented) BEDROOM
30
Blown
145 ft'
0.1
Wood
12 Under Attic(Vented) CLST3
30
Blown
18 ft'
0.1
Wood
_
13 Under Attic(Vented) LAUNDRY
'14 under
30
Blown
54 R'
0.1
Wood
.Attie (Vented) HALL
30
Blown
72IF
0.1
Wood
15 Under Attic.(Vented) NOOK
30
Blown
116f2
0:1
Wood
5121/2018 4:05 PM t EnergyGauge® USA - FlaRes2017 Section R405A.1 CwnpiiantSoftware .Page 3 of.6-
T
IIIIIIIIII,IIII
II
I
I
I1I
IIIII�
N
GI
N
A
pp
N�
b
0
m
V
T
'N A
lJ
N
+
O
fp W
V OI
N
A
W
N
mr Ou V
W m
A W
N
A
m
m
z
g
m
W
m
m
m m
z
z
m
m
m
z
m
z
m
z
Y,
m z z
m z
0�
Z
m
Z
O
3
m
�mn
mm
m
�r1
m
N
i5.
II
Km
tt
'S
m
2S
ttm
m
m
7i
m
m
tmi
m
7s
m
n
�i
$
�xpm
t
"pdj'
5
Y
5
Y Y
Y
Y
5
Y
m
Q
O
O
0
O
O
Q
O
0
0
0
0
0
Q
0
0
0
O. 0
0
0
0
0
0
r
m
r
99
r
m
9 rq
4 rq
r
gg
r
gg
r
gg
qqr
y
O
"
fD
�ro
m
m
mmm
m
m
f
i
2
f
f
f
2
c
g
a
Co'
m
m
m
m
m
m
W
m
m
i�o
m
m
io
m
!�
m
0
m
m
mm
m
m
m
m
m
-p
�.
�
g
p
m
m
m
m
m
oo
m
mm.
m
m
m
m
m
m
m
m
m
m
m
R
R
8
R
R
R
8
R
R
S
m
m
m
m
m
m m
mm
m
m
m
mca
m
F
F
iC
F
F
8
JC
8
8
F
A$
A
8 R
k
8
R
m
a
m
m
a,B
m
m
m
OF
jm9iCj
�mFn
mF
(mJnC
�Fn
�mn
tmFn
JC
F
F
X
A
am
2i
A
A
A
A
.'i
iS
�mFn
S��#
mm
A
jmfT1 mmF
A A
mF
A#
OM
(mi1
ti
>
>
>
J
>
>
>
J
7
6
J
>
>
>
>
iS
>
>
O
O
O
Z
Z
m
O
O
0
0
0
0
Z
Z
m
m
m
a
O
O
0
m
3
N
E
3
2
z
N
N
N
m
C
J
A
A
A
A
A
A
A
W
W
N
N
O m
m
�
(V
m
y
S
A
A
A
A
A
a
A
A
-
A
�
A
-
A
A
�
A A
A
A
-
A
A
A
2.
0
-
- -
-
-
-
J
CC
G
O
O
O
O
ON
O
O
O=
90
NNO
N-+.
N
z
m
a
$
z
z
z
z
z
z
z
z
z
a
W
o
o
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 0
0
0
o
Q
o
2
S
C
�`
w
x
.^�^.
^
�•
O
-N+
w
O
o
O
o
OND
is
0
o
0
0
0
0
0
0
0
0
0
0
0
0'
0
N
0
A W
0 0
N
0
O
Ri
0
0
0
0
0
0
0
0
0
0
0
0
0 0
o
0
o
O
m
�
S
O
z
z
O
T
§
9z
9
3Z
§z
T
0
0a
0a
0b�
0a
0m 'Om
0o�
0m� 0
p
0m,
p 0
p 0
c�
a0 m0
c0�
b0�
u0i
m0 m0
m0
m0
y
$
R
z
z
z
z$
z
R
m
p1
m
m
m
m
m
m
m
m
m
m
i
FORM R405-2017
WINDOWS
Orientation shown Is the entered, MPosed orientation.
/
Wall
-
V #
Omt ID- Frame Panes
'
NFRC U-Factor SHGC Imp Area
Overhang
Depth Separation
9MShade
Screening
10
S 17 Vinyl Low-E Single
Yes 0.32 0.22 N 15.0 fP
1 It 0 in 1 ft 4 in
None
None
11
S 19 Vinyl L aw-E Single
Yes 0.32 0.22 N 8.0 ft'
1 ft 0 in 1 R 4 in
None
None
12
_ N 21 Vinyl Low-E Single
Yes 0.32 0.22 N 15.0 ft°
t ft 0 In t It 4 in
None
None
13
NE 22 I Vinyl Low-E Single
Yes 0.32 0.22 N 10.0 ft'
1 It 0 in 1 ft 4 in
None
None
14
E 23 IV'inyl La ESingle
Yes 0.32 0.19 N 20.0 ft'
1ft01n 1d4in
Nooe_—None—
_-15—W�4
III4VInyi—Cow-E Single-
Yes 0.32 0.19 N 20.0 R2
_
t.ft0in 1ft41n
None
Now
—_ 16
NW 25 Vinyl Low-E Single
Yes 0.32 0.22 N 10.0 ft'
1 ft 0)n t ft 4ln
None
None
INFILTRATION
# Scope
Method
SLA CFM 50 ELA, EgLA
ACH ACH 50
1 Wtidehause :Proposed ACH(50) .000447
2024.2 111.12 208.99
.3266 7
HEATING SYSTEM
#
SystemT `
YPe
.. -
Subtype -Efficiency Cepacfty
Block,
Ducts
1
,Electric SMp Head
None COP:1 27 kBtu/hr -
1
sys#1
COOLING SYSTEM
#
System Type
Subtyper Efficiency Capacity
Air Flow SHR Block
Ducts -
1
Central Unitl
Split SEER: 16 '36 kBtu/hr
1080 cfm 0:8 Y
sys#1
i
HOT WATER SYSTEM
#
System Type SubType
Location EF Cap - Use
SetPnt
.Conservation
Electric ( None
Exterior 0.98 50 gal 60.9 gal
120 deg
Now
SOLAR HOT WATER SYSTEM
Can
Cart
# Comps I y Name
System Model .# Collector Model
Collector
# Area
Storage
Volume
FEF
None None i
- -
DUCTS
/
V #
—Supply—
LooationI
R-Value Area
—Realm— Air
Location Area
CFM 25 CFM25
HVAC#
Leakage Type Handler
TOT OUT
ON RLF
Heat Cool
1
Attic..
6 1501P
I
Attic 15ft' Default Leakage Attic
(Default)c(Default)�c
1 1
521/2018 4.05 PM i EnergyGauge® USA -. FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2017
TEMPERATURES
Programable��Thennostat: j']N
C[eilling Fans:
Heating 00 Jan
Venting Jan
Feb
r[?9']
Maarr
]
E ]
[
May�0
] May
)) Jun
�0
) ) Jul
[X�
`)Aug
P(�
[ ] Sep
[ ] Oct
L 1
Nov
Dee
jj jj
[ ]Feb
l l
[X) Mar
lnl
IXJ AR
[
1
1 1 Jun
[ 1.Jul
I 1 Aug
I 1 Sep
lXl OctOct
X Nov
j Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
{
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
IAM
iPM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
80
80
80
Cooling (WEH)---!AM
!PM
78
80
78
80
78
80
78
78
78
78
78
78
80
78
78 _
80
78
___
80
80
76
78
78
78
78
7880
76
78
Heating(WD)
!AM
I,PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
Heating(WEH)
JAM
PM
65
68
65
fi8
85
68
65
65
65
65
68
68
68
68
68
68
68
68
68
68
68
68
68
68
68
6B
68
68
5/21/2018 4:05 PM I EnergyGauge® USA - FlaRes2017 Section R405:4.1 Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Pmject Name: SHOWEN RESIDENCE Builder Name: TC CUSTOM HOMES
Street SILVER OAK
City, State, Zip; PORT ST LUCIE FL, Permit Office: CITY OF PORT ST LUCIEPermit
, Number;
Owner.
Design Location: FL, Fort Pierce Jurisdiction:
COMPONENT—
- j AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air baffler shall be Installed in the building envelope.
The wdedor thermal envelope contains
Air -permeable insulation shall
requirements
a continuous air barter.
Breaks orjointsin the air barrier shall be sealed,
not be used SS sealing material.
Ceiling/attic
The air barrier in any dropped ceilin&offd shall be aligned with the
insulation and any gaps in the air barrier shall be Sealed.
The insulation in any -
dropped ceilinglsofft
Access openings, drop down stairs orknee wall.. doors to
shall be aligned with the air barrier.
unconditioned attic spaces shall be sealed.
Walls
Thejuncum of the foundation and sill plate shall be sealed.
The junction of the top plate and the top of exterior
Cavities within toners and headers of frame wells shall
walls shall be sealed,
Knee walls shall be sealed,
be insulated by completely tilling the cavity with a
I
material having a thermal resistance of R-3 per Inch
In
minimum.
1
Exterior thermal envelope insulation for framed wells
{
- shall be installed in substantial contact and continuous
Windows, skylights
The space between window/doorjambs and framing, and
alignment with the air barrier.
and doors
skylights and framing shall be sealed.
Rimjoists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
(including
The air barrier Shall be installed at an g
i Y exposed edge of insulation.
Floor framing cavity insulation shall be installed to -
above -garage
maintain permanent contact with the underside of
and cantilevered floors)
I
subfloor decking, or Floor framing cavity insulation shall
bepermittedto be: in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
F-xposed earth in unvented crawl spaces shall be covered with a
Class l vapor retarder with overlapping joints taped.
Whom Provided instead of floor insulation, insulation
-
shall be permanently attached to the crawlspaea wails.
Shafts, penetrations
Duct shafts; utility penetrations, and flue shafts opening to exterior
aunconditioned Space shag be sealed.
Narrow wvitles
i
Batts In narrow cavities shall be cut to fit, or narrow
I
caMUes shall be filled by insulation that on installation
I
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the and
garage conditioned spaces.
Recessed lighting
Recessed light fcdures Installed in the building thermal envelope shall
besealed to the drywall,
Recessed light fixtures installed in the tiuiltling
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
I
-
Batt insulation shall be cut neatly to fit wound wiring and
plumbing in exterior walls, or Insulation that on
Installation readily conforms to available space shall
Shower/tub
-
The air barrier Installed at a#eriorwalls adjacent to showers
extend behind ' in - and wiring.
on exterior wall
and
tuffs shall separate them from the
Exterior walls adjacent to showers and tubs shall be
showers and tubs.
insulated.
Electricallphone box on
The air barrier shall be Installed behind electrical or
eterior walls
communication
boxes or air -sealed boxes shall. be installed.
HVAC register boots
HVAC register boats that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed When required to be sealed, concealed fire sprinklers shall only be sealed
Sprinklers in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
'err
etas antl walls or ceilin s.
a. In addition, inspeetionof log walls shallbe in accordance wllh rtia nrrnriefnna nr trrann
5121MI8 4:07 PM i EnergyGauges USA- FISRes2017 FBC 8th Edition (2017) Compliant Software Page 1 of 1
i
FORM R405-2017
ENERGY
i
PERFORMANCE LEVEL (EPL)
DISPLAY CARD
�i I IMA I ED ENERGY PERFORMANCE INDEX* = !
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or ewsting
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms i
5. Is this aworst case? t
6. Conditioned floor area (fp):
7.. Windows" Description
a. U-Factor. Sgt. U=0.32
SHGC: SHGC=0.19
b. U-Factor. Sgt. U=0.32
SHGC: SHGC-0.22
C. U-Factor. S91, U=om
SHGC: SHGC=0.21
d. U•Factor. N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types I
a. Slab -On -Grade Edge Insulation
b. N/A I
c. N/A
i
i
I
I certify that this home has complied
Construction through the above en
in this home before final Inspe
based on installed Code cony t fE
Builder Signature:
Address of New Home:
SILVER OAK, PORT ST LUCIE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block- Ext Insul, Exterior
R=4.1
2038.00 W
1
b. WA
_
c. N/A
R=
it,
3
d. N/A
R=
ft-
No
10. Ceiling Types
Insulation
Area
1725
a. Under Attic (Vented)
R=30.0
1725.00ft
b. NIA
R=
ft-
Area
c. WA
R=
W
152.00 ft-
11. Ducts
R W
a. Sup: Attic, Ret Attic, AH: Attic
6 150
88.00 ft'
12. Coding, systems
kBtulhr
Efficiency
27.00 ft-
a. Central Unit
36.0 SEER:16.00
fN
13. Heatlng systems
kBtu/hr
Efficiency
9.000 R
S. Electric Strip Heat
27.0
COP:1.00
0.202
Insulation
- Area
14..Hot water systems
R=0.0
1724.00 ft'
a Electric
Cap: 50 gallons
R=
ft-
EF: 0.98.
R=
ft,
b. Conservation features
None
15. Credits
None
h the Florida Energy Efficiency Code for Building
saving features which will be installed (or exceeded)
hey(vise, a new EPL Display Card will be completed
Date: f -171-1 5-
City/FL Zip:
i
`Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. Forlinformation about the Flodda.Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
"Label required by
5121/2018 4:06'PM
R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1