HomeMy WebLinkAboutMANUFACTURED HOME INSTALLATIONManufactured Home Installation Specifications
(Must be completed and submitted with your application)
Applicant Gail Marcella
Address 404 Nettles BLVD
OCT 10 2019 Pe I
it#
JENSEN BEACH, FL 9TUusl@ (:Q permitsins
Manufacturers Name JACOBSEN
Roof Zone Wind Zone 3
No. of Sections 2 Width 20 Length 39/40
Installation Standard Used (check) Manufacturers Manual YES
Year 2019 Serial #
15C-1
SCANNEL,
BY
St. Lucie Countv
Site Preparation
Debris and Organic Removal YES Page #
Water Drainage: Natural Swale Pad YES Other Page #
Foundation
Load bearing soil density 1500 Or assumed 1,000 psf
Page #
Footing type: Poured in place Portable YES
Page #
Mainrail frame block: Size 17X22.5 Placement o.c.
Page #
Perimeter blocking: Size 16X16 Number Location
Page #
Ridge beam support: Number Size Location
Page #
Center line blocking: Number Size Location
Page #
Special supports required (fireplace, bay window) Yes _ No X
Page #
Mating of Units: Mating gasket FACTO RY Type used FOAM
Page #
Fasteners: Roof Type GALV Spacing O.C.
Page #
Endwall Type LAG 611Spacing 24it O.C.
Page #
Floors Type LAG 611Spacing 2411 O.C.
Page #
Anchors: Type 6,000 3,150
Page #
Height of Unit (top of foundation to frame):
Page #
Angle of straps 45
Page #
Number of frame ties 20 Spacing 4 O.C.
Page #
Number of over -roof ties (if required)
Page #
Number of sidewall anchors 20 Zone II Zone III
Page #
Number of centerline anchors 20 Number of stabilizers
Page #
Vents required for underpinning (lsf/150 sf floor area): No.
Page #
Prepared by: Y nyJ Date: 09/26/2019