HomeMy WebLinkAboutREVISIONOFFICE USE ONLY:
DATE FILED:
REVISION FEE:
PERMIT # Cl I D - d 2"2-71
RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2399`VI RGINIAAVENUE SCANNED
FORT PIERCE, FL 34982-5652 BY
(772) 462-1553 St. Lucie County
LOCATIOWSITE
ADDRESS: + `b, f
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
v7
DETAILED DESCRIPTION OF PROJECT
REVISIONS: ^ dw� ,(� ,�& . 1
T�'
\��
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: 114 (1 l8 u ko-�
BUSINESS NAME: l bV`+�S Y`(� \A
QUALIFIERS NAME: I^n'c<
ADDRESS: ^2
CITY: �Z-a^ STATE:
PHONE (]DAYTIME): y6<I Rbq \y+GU
OWNERBUILDER INFORMATION:
NAME:
CITY:
PHONE (DAYTIME:
STATE:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS --
CITY:
PHONE (DAYTIME):
A,
�^; h" E a i
STATE:
ST. LUCIE CO CERT. #:
FAX:
ZIP:
ZIP:
ZIP:
HARDI PLANK SIDING OR EQUIVALENT SKIRTING DETAIL
P.T. STUD TO TOP PLATE/RIM JOIST CONNECTION
SGL. P.T TOP PLATE. STAGGER SPDCES
SIMPSON'S H6 STRAP OR EQUIVALENT.
P.T. PERIMETER WALL FRAMING
P.T. 2 X 4 STUDS 0 24" O.C. FASTENED USING 16D
NAILS. P.T. WALL TO BE COVERED WITH THERMO-PLY
(.113 THICKNESS). THERMO-PLY TO BE INSTALLED
WITH 1-1/4" GALVANIZED ROOFING NAILS OR EQUIV.
THE FASTENING SCHEDULE IS 3" O.C. ON ALL PANEL
EDGES AND 6" O.C. ON INTERMEDIATE SUPPORTS. ALL
JOINTS SHALL OCCUR OVER STUDS. THERMO-PLY TO
BE COVERED WITH HARDI SIDING OR EQUIV. HARDI
SIDING INSTALLED PER MANUFACTURER'S INSTRUCTIONS.
SIMPSON'S H2.5
3'-0" O.C. W/ (1) 2" X 2" THICK WASHER
A SECTION "A"
s—z
P.T.2 X 4 TOP PLATE TO RIM 401 T CONNECTION
FASTENED TO RIM JOIST USING SIMPSON'S 1/4" X 3" SDS
WOOD SCREWS OR EQUIVALENT 0 16" O.C. SPACING.
(STAGGERED SCREW PATTERN) MATEUNE
OUTRIGGER
FLOOR JOISTS
FRAME
-P.T. 2X8 WOOD SHIM
8"X16" CMU BLOCKS '
DRY STACKED /—EXISTING CONCRETE SLAB
SIDEWALL PERIMETER PIERS NOT SHOWN FOR CLARITY (REFERENCE PG. F-1)
MAX
VENTILATION NOTES
1) VENTILATION OPENINGS SHALL BE COVERED FOR THEIR HEIGHT AND WIDTH
WITH A PERFORATED (1/4 INCH MAXIMUM OPENING IN ANY DIMENSION) CORROSION
AND WEATHER RESISTANT COVERING THAT IS DESIGNED TO PREVENT THE ENTRY OF
RODENTS.
2) A VENT SHALL BE INSTALLED WITHIN 3'-0" OF EACH CORNER OF STRUCTURE
1) IF HOME IS TO BE PLACED IN A FLOOD ZONE, THE LAP SKIRTING WALLS WILL REQUIRE
HYDROSTATIC VENTS. ACTUAL VENT LOCATIONS ARE DICTATED BY SITE CONDITIONS AND WILL
BE LOCATED ONSITE BY CONTRACTOR. THE BOTTOM OF EACH OPENING IS TO BE LOCATED NO
HIGHER THAN 1 FOOT ABOVE THE GRADE THAT IS IMMEDIATELY UNDER EACH OPENING.
2) FLOOD OPENINGS SHALL HAVE A TOTAL NET AREA OF NOT LESS THAN ONE SQUARE INCH
FOR EVERY SQUARE FOOT OF ENCLOSED AREA SUBJECT TO FLOODING. OPENINGS MAYBE
EQUIPPED WITH SCREENS, LOUVERS, OR OTHER COVERINGS PROVIDED THAT THEY PERMIT THE
AUTOMATIC ENTRY AND EXIT OF FLOOD WATERS.
VINYL LAP, HARDI BOARD, OR EQUIVALENT SKIRTING
INSTALLED PER MANUFACTURER'S
INSTRUCTIONS.
SCANNED
BY
Lucie County
STUCCO APPI I ATION (OPT) -WOOD -FRAMED WAI I S
OMIT THE THERMO-PI Y AND VINLY SIDING WITH STUCCO APPI I ATION
1/2" MIN. P.T. PLYWOOD FASTENED TO WALL STUDS EVERY 3" ON THE
EDGE OF THE P.T. PLYWOOD AND EVERY 6" IN THE FIELD USING 6D
NAILS OR EQUAL THE P.T. PLYWOOD SHOULD BE COVERED WITH FELT
PAPER, METAL LATH, AND STUCCO FINISH.
FLOOR JOIST
2"x4" TOP PLATE
CONCRETE SLAB
REVIEWE
CODE COMPLIANCE
ST• Ll
i_�5STATE
itto a;30-2019
�ACENrEIYNo. 56196
. OF ,r.
Fs F4"0-R1����
/ONAL .�
MIMP-4682OW (M1795*)
MIMP-4682OW (M1795*)
N\j1 2017 CODE, VERSION
`J F26ruary 4, 2020 f
ULTIMATE Design Wind Speed:160 h1oh
Wind Exposure Category: D
Mean Roof Weight: 30 ft.
FLORIDA_PROD►UCT APPROVAL SPECIFICATION SHEET:
C&C Loads Based On AU606ble Stress Design as converted from the Ott mate or Strength Design
As required by Florida Statute 553.842 and the Florida Administrative Code 61-GZO-4-006,
the information and approval numbers on the building coenodnents are listed below:
-Category/ _i'
SBbcategory
Manufacturer,
. w
Product,Descnption M
FL Product
,
Apprpval
Nurribapl
1. Exterior Doors
A Swinging
Dunbarton Corp.
2 Panel In -swing or Outswing - IMPACT
FL 15341.3-R7
Swinging
Dunbarton Corp.
6 Panel In -swing or Outswing - IMPACT
FL 15341.3-R7
Swinging
Jeld-Wen
Single orDouble - Outswing -IMPACT
FL14569.1-R9
Swinging
Dunbarton Corp.
In -swing Exterior Door -Solid
FL 15362,1-R2
Swinging
Dumbarton Corp.
'In -swing Exterior Door - Oval.
FL 15362.1-112
Swinging
Dunbarton Corp.
In -swing Exterior Door-9 Lite-
FL 15362A-R2
Swinging
Ounbarton Corp.
Patio Door
FI 15326.9-R3
I
B Sliding
Shwinco.Architecturel
Sliding Class Door- Exterior
FL12519.2-R4
C French (Single)
Custom Windows, Ind,
8700-50 Single French- IMPACT
FL 14850.1-R3
French (Double)
Custom Windows, lk,
87S0-Pp Double French - IMPACT
FL 14850.11-R3
2. Windows
A Single Hung
Shwinco Architectural
Series 9000 Tilt $Ingle Hung -IMPACT (-16D)
FL8153,1-R$
Single Hung
Custom Windows, Ind.
8100 -SH IMPACT Resistant- Low E (40)
FL5823.4 a R8
Single Hung
Shwinco Architectural
Series 90007iItSingle Hung -IMPACT (-70)
FL8153,4-R$
Single Hung
Custom Windows, Inc,
8100-SHIMPACT.Resistant-- Low R(-70)
FL5823,2-R8
Single Hung
Kinro, Inc.
9750 Series - Insulated - Lowe.
FL 993.2 - R15
B Fixed
HyrLite Products, Inc.
Acrylic Block Window -6"BLOCK
FL185,1-R10
Fixed
Hy-Lite Products, Inc..
Acrylic. Block Window -8"BLOCK
FL.185.2-R10
SCANNED
BY
St. Lucie County
t
5 pass/ Fail
PASS - INT/END ZONES
PASS = INT/ENDZONES
PASS - INT/END ZONES
PASS- INT ZONE ONLY
PASS = INT ZONE ONLY
PASS INT ZONE ONLY
PASS =INT ZONE ONLY
PASS = INT/END ZONES
PASS- INT/END ZONES
PASS : INT/END ZONES
PASS - INT/END ZONES
PASS INT/ENDZONES
PASS- INT/END ZONES
PASS - INT/END ZONES
PASS- INT/END ZONES
PASS = INT ZONE ONLY
PASS-JMZONE ONLY
;e
L
r � � ,�
��� , Manuf�cturer ��
� Pr4duet�DE crlptiot► c °; ��;
,ARPrR����'"`
YA .R
"
D Metal Roofing
Advanced Aluminuni
Advantage Panel - 26 Ga.
FL 1763,1 R3
E Tubular Skylight
Sun Tek
Tube (self flashing)10", 14" or 21"
FL13488JQ, RS
5. Structural Comp.
A
Wood Connectors
Tie -down Engineering
Coll Strap
Local Approval
Wood Connectors
Oliver Technologies
Coil Strap
Constellation Tech.'
Wood Connectors
Master Craft Eng,
Metal Strap
Report =A131394
I
$ Truss Plate
MiTek
Truss connector plates
FL 2197 x Qfi
C Engineered Lumber
GP
GP -Lam
FL2023:1-R6
PASS-
PASS- INT ZONE ONLY
PASS - INT/END ZONES
PASS,- INT/END, ZONES
PASS - INT/END ZONES
PAS5 < INT/END ZONES
PASS- INT/END ZONES
SategoNJ! r
t Subcategory
ufacturer
Manel
Prbduct Descnptton
, �
_�^
Pr
Afippr6va[41
x Number{s)
3. Panel Wall
A Siding
JamesNar '
Sidi S 6" Sheathin Req'd)
FL 10477= R6
Siding
James Hardie
GEMPLANKSiding
FL>13192 a IRS
Siding
Nichi a , .
Cement Siding (5/8" Sheathing Req'd)
FL 120981'4tB
Siding
Style Crest
Vinyl Siding
FL 12231.6-94
Siding
Plygen
Vinyl Siding
FLZ40581
B Soffits
James Hardie
Hardie Soffit Panels
FL1326M� R3
4. Roofing Products
A Asphalt Shingles
Tamko Building Product$
Asphaltshingles
FL 18355=114
Asphalt Shingles
GAF
Asphalt Shingles
FL10124A-1420.
Asphalt Shingles
OvJens'Corning
Asphalt Shingles
FL.10674.1 --R13
B Underlayment
Tamko Building Products
Underlayment
FL 12328 r H8
Underlayment (
Tamko Building Products
TW Underlayment
FL 12328 = R8
Underlayment
Johns Manville
Ice &'Water Guard
FL 5301- R5
Underlayment.
Woodland Industries
1SLB Felt
FL 17206 - R4
C Cements/Coatingsi
Tamko
Roof Cement
FL1960=R10
t ements/Coatings!
I
Certainteed Corp,
Roof Cement
FL 490- 99
PASS , INT/END ZONES
PASS - INT/END ZONES,
PASS - INT/END-ZONES
PASS - INT/END ZONES
PASS - INT/END ZONES
PASS - INT/EN D ZONES
PASS, INT/ENDZONES
PASS - INT/END ZONES
PASS ,rINT/ENDZONES
PASS= INT/ENDZONES
PASS - INT/END ZONES
PASS - INT/END ZONES
PASS - INT/END ZONES
PASS - INT/END ZONES
PASS - INT/END. ZONES