Loading...
HomeMy WebLinkAboutNOP CERTIFICATION..voo2 NOTICE OF PRODUCT CERTIFICATION ST. Lucle County, Permitting .,I if I yAeI '",�Ry Company: Masonite International Corporation Certification No.: NI013747-RI 1955 Powis Road Certification Date: 06/08/2017 i II West Chicago, IL 60185 Expiration Date: 06/30/2021 *,k Revision Date: 04/13/2018 Product: Wood -Edge Steel Opaque Inswing or Outswing Door w/Non-Impact Rated Sidelites SCANNED "rt (w/Wood Frame unless noted) BY e Specification: TAS 201/202/203-94 I St. Lucie County Impact: Large Missile Impact Rated Non -Impact Glazing: Insulating Glass (Tempered) The "Notice of Product Certification' is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing witbin NAMPs Certified Product Listine at wwwAamicertification.com. NAMIN Certification Prooram is accredited by The American National Ctnndnrds Instittrte tANRt1- Inswing Glazed Structural Water Missile Test Report Number Configuration or or Maximum Design Test Impact Drawing Number & outswing OP a ue Size Pressure Pressure Rated Comments X 1/S Opaque 3'0" x 6'8" +70/-70 0.0 psf Yes ATLNC 1001.01-13 Single Maximum Panel Size: 3'0"x6'8" Anchor Details-DWG-MA-FL0211-17 X O/S Opaque 3'0" x 6'8" +70/-70 3.0 psF Yes ATLNC 1001.01-13/W-1857 Single 4.5 psf' Maximum Panel Size: 3'0" x 6'8" 7.50 psf Anchor Details-DWG-MA-FL0211-17 XX its Opaque 6'0" x 6'8" +551-55 0 psf Yes NCrL-210-2930-1 Double Maximum Panel Size: 3'0" x 6'8" Anchor Details-DWG-MA-FL0211-17 XX O/S Opaque 6'0" x 6'8" +55/-55 3.0 psf Yes NCTL-210-2930-1 Double 4.5 psf' Maximum Panel Size: 3'0" x 6'8" 7.50psf' Anchor Derails-DWG-MA-FL0211-17 XO/OX I/S Opaque Door 6'0" x 6'8" +551-55 0 psf Door -Yes NCTL-210-2930-I Single w/Sidelite Glazed Sidelite Sidelite-No Maximum Panel Size: 37' x 6'8"/Sidelite: 3'0" x 61" Anchor Details-DWG-MA-171,0211-17 XO/OX O/S Opaque Door 6'0" x 6'8" +551-55 3.0 psP Door -Yes NCTL-210-2930-1 Single w/Sidelite Glazed Sidelite 4.5 psf' Sidelite-No Maximum Panel Sim: 3'0" x 6'8" /Sidelitc: 3'0" x 6.8" 7.50psf' Anchor Details-DWG-MA-F1.0211-17 OXO I/S I Opaque Door 9'0" x 6'8" +551-55 0 psf Door -Yes NCTL-210-2930-1 Single w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8" - Anchor Details-DWG-MA-FL0211-17 OXO O/S i Opaque Door 9'0" x 6'8" +551-55 3.0 psP Door -Yes NCTL-210-2930-1 Single w/Sidelites Glazed Sidelite 4.5 psf' Sidelites-No Maximum Panel Size: 3.0" x 6'8" /Sidelite: 3.0" x 6'8" 1 7.50psf' Anchor Dctails-DWG-MA-FL0211-17 OXXO I/S I Opaque Door 12'4" x 6'8" +551-55 0 psf Door -Yes NCTL-210-2930.1 Double w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size: 3'0"x6'8"/Sidelite: 3'0"x6'8" Anchor Details-DWG-MA-FL0211-17 OXXO O/S Opaque Door 12'4" x 6'8" +551-55 3.0 psf Door -Yes NCTL-210-2930-1 Double w/Sidelites Glazed Sidelite 4.5 psf' Sidelites-No Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" 7.50 sf' Anchor Details-DWG-MA-FL0211-17 -Denotes Bumper Outswing Threshold 2-Denotes ZSeries Outswing Threshold 3-111-Dam Outswing Threshold 4-Pro T4 Threshold 5-HP Ounwing Threshold National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072 Tel: (804) 684-5124/Fax: (804) 684-5122 NAMI AUTHORIZED SIGNATURE: _"4� nl MASONITE. WOOD -EDGE STEEL DOOR UNIT 6'-6" DOUBLE DOOR WITH/ WITHOUT SIDELITES GENERAL NOTES I 1. EVALUATED FOR USE IN LOCATIONS ADHERING TO THE FLORIDA BUILDING CODE AND WHERE PRESSURE REQUIREMENTS AS DETERMINED BY ASCE 7. MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, DOES NOT EXCEED THE DESIGN PRESSURES LISTED. 2. HURRICANE PROTEC'NVE SYSTEM (S 7MGn) 6 NOT REQUIRED ON OPAQUE PANELS, BUT 6 REQUIREEOO ON GVSED SIDELITES. 3. WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION, EXCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVIIZ), HURRICANE PROTECTIVE SYSTEM 6 NOT REQUIRED ON OPAQUE PANELS OR PANELS WITH IMPACT GLASS, BUT IS REQUIRED ON PANELS WITH NON -IMPACT GLASS. 4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. S. PLASTICS TESTING: Trc nrcnRiRnnu SELF IGNITION TEMP ASTM D1929 B42 'F > 850 'F NATE OF BURNING I ASRA D675 1.28 IN/MIN _ SMOKE DENSITY ASTM D2943 70.2R I TENSILE STRENGTH- ASTMM D638 1.BA DIFF • COMPARATIVE TENSILE STRENGTH AFTER WEATHERING 4500 HOURS XENON ARC METHOD 1 f it ■. �■ %; ■ '■_. _■' 11 III II ��I� �11 l iI 'll '1� jl� III IIIT rrrj �/ NFIG I MAX WIDTH X 37.5 %X 4 OX %0 5 O%0 112.5 OX%0 149 149" MPX. OVERALL FRAME RIM 21" MAX J6.375" MAX. D.L.O. - PANEL WIDTH 37.5" MAX. W/ASTRAGAL I FRAME WIDTH m O W b Lo o i � a DESIGN PRESSURE RATING WHERE WATER INFILTRATION PERFORMANCE IS REQUIRED TO BE 15% OF DESIGN PRESSURE INSWING U IN INSWING BUMPER 0 S Z- SERIES O S HIGH DAM 0 4 0 S HP BUMP O S +70.0 -]0.0 + D.0 -70.0 N A +20.0 -20.0 +30.0 -30.0 +SO.O - 0.0 +50.0 -50.0 +50.0 -50.0 .0 +55.0 -5 .0 N A +20.0 -NO + 0.0 -30,0 +50.0 -50.0 N A N A N A A N A +55.0 - .0 I +55.0 -35.0 N A +20.0 -10.0 +30.0 -30.0 +50.0 -50.0 N q I No TABLE OF CONTENTS SHEET #1 DESCRIPTION 1 1TYPICAL ELEVAPONS & GENERAL NOTES 2 ANC ORING LOCATIONS & DETAILS 3 ANCHORING LOCATIONS &DETAIL$ e';e aVy- KURT HALTHAZOR FLORIDA P.E. IF56533 N O 0 N . 0 Q (L W F :D Q <� I az I 5126117 N.T.S. SINS BY uP Ha: �MA-R0211-1] 1 rF� 1` SEE DETAIL 'C' M 6'3 i I 3 SEE DETAIL3 3. c I I I 6' 6' —I 6 6' 3' � g OA A _ B w 0 B s II 8' Ir 8' 3' 6' � II e 3' t 3' c 3' e I � —I 1� 3.1 6'3'ff ' 3' --{{ 3' SEE DETAIL 3- #8 X 2" (/8 x 2" //10 x 518" #8 x 2" 5/8" �10 x 2—i/2" //10 x 1" ATTACH ASTRAGAL RETAINER BOLT 10 x 1" STRIKE PLATE TO FRAME #10 x 5/8" AS SHOWN. DETAIL "D DETAIL "C"" 1 1.375' 0.962' 1.� 1 1.437' T T T �� INSWING THRESHOLD, BUMPER O/S THRESHOLDO/S THRESHOLD T4 O/S THRESHOLD 1 1. 2' 1.75' j 7' 1.437' T T T �y Z—SERIES 0/S THRESHOLD HIGH DAM O/S THRESHOLD HE O/S THRESHOLD Hm MT Hm MUT EE DETAIL 6' ASTRAGAL RETAINER BOLT HOLE MUST BE DRILLED THROUGH THE THRESHOLD & INTO THE STRUCTURE DEEP ENOUGH FOR A 1.375" THROW .DETAIL "F" ASTRAGAL /6 x 1-1/2• PHS 1/2. 6IIE ffiEIDDB 'V--�� R�BI06 TYPICAL GLAZING DETAIL NON —IMPACT GLASS SEE DETAIL 'C' SHT. 2 ATTACHMENT DETAIL 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, SIGNED AND SEALED BY ROBERTO LOMAS, PE (FLORIDA #62514) WITH THE LOWEST (LEAST) FASTENER RATING FROM THE DIFFERENT FASTENERS BEING CONSIDERED FOR USE. JAMB, HEAD, AND THRESHOLD FASTENERS ANALYZED IFOR THIS UNIT INCLUDE #10 WOOD SCREWS OR 1/4" TAPCONS. A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". WOOD SCREW EDGE DISTANCE MINj 3/4". w U a SEE D. 0 6 g• 3 _6. I I— 3' 6" 6' to 0 na. — — 0 w w 9 I I G H II II R I rc f 3' -i i- t 3.6 F e 6'—Ll �ii3.I 6'� �_.6- 1. ry 4 — 0 22K5" SHIM CIL TYPICAL MASONRY ANCHOR INSTALLATION 2 SCREWTHE WOOD SINGLE SHEAR ANSI/AF&PANDAFOR SOUT ERN �INEGO LUMBER A DACHEVEMENT iMIN• OF 1-1/2 MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE MINIMUM EMBEDMENT OF 1-1/4".I 3. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO STRUCTURE. 1 4. MINIMUM DESIGN VALUE STRENGTHIOF ANCHORS 155 LBS. 1.25' ;HIM TYPICAL WOOD BUCK ANCHOR INSTALLATION HARDWARE SCHEDULE _ 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED IAT 5-1/2 CENTERLINE. 2. 4" X 4" FULL MORTISE BUTT HINGES. 1'K1 2' CORRUGATED %1OKY WOOD SCREW 3' FFRROM EACH END 6" FROM EACH END AND 7' OC AND 12' OC � RyL MATE"%C CAULK MY C I CAULK CL CMULLON WOOD ONION WOOD (BOXED) MULLION TI(BOX D) (3WODD SCR92S EACH END e o• INTEGRAL WOOD MULLION (CHS) Add¢rdmilpLLY' AM C•GTDOT•N¢:. gAMI�A Is"".. N.T.S. I W. L. Roberto Lomas P. E. 1432 Woodford Rd. Lewisville, NC 27023 43a688-0609 dlomas( 1domasoe.com Manufacturer: Masonite Report #: 514010 Date: 05/01/2017 Test Report: N/A Product: Single door Tx 68" (Wood Frame) Scope: This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the product described herein. These calculations comply with requirements of the Florida Building Code. Anchor capacity in shear condition: Solid members w/ 6 w/nd gap: a. With threads present In shear plone ' Fastener, type: 910 wood screw (NDS 2012, TR12) Ncmmal diameter: D: 0.190 in bap: g: 0.0000 in Root diameter: Or: 0.1521. Moment arm: 0.0000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: F,= 80,000 psi Side member: Douglas Fir -Larch (6=0.50) Main member: Spruce -Pine -Fir (6=0.42) Sidememberthicknes: t,= 1.000 in Main member thickness. Us; 1.500 in Side member dowel bearing strength: F. = 4,650 psi Main member dowel bearing strength: F,. = 3.350 psi Side member dowel bearing length: 1. = 1.000 in Main member dowel bearing length: I. = 1.140 in Mode-. Made I. ModeII Modelun qm= 636.5 lbs/in qs= , 884 lbs/in A: 0.0007 A: 0.00096 P= 725.61 lbs P= 884 lbs B: 1.07 B: 057 Ka= 2AOO Katz 2.400 C: 427.67 C: -253.62 7,= 3021bs Z,= 368 lbs p= 331 lbs Mott 46.8 in-lbs Ka= 2.400 P= 297 lbs Min Design value: Z= 110 lbs Z= 1381bs Ka= 2.400 Duration Factor: Ca= 1.6 Z= 124 lbs Allowable Design Value (ZCa): Z'= 175 Ibs/arwhor Mode III, A: 0.00107 B: 0.5 C. -267.7 Mm= 46.8 in-lbs P= 319 Ibs Ka= 2.400 Z= 133 lb. Mode IV A: 0.0014 8: 0.000 C. -93.6 P= 263 lbs Ko= 2.400 Z= 110 lbs Solid members w/ 6 w/out gap: a. With threads present in shear plow Fastener type: #10 woad screw (NOS 2012, TR12) Nominal diameter: M 0.190 in Gap: g: 0.0000 in Root diameter: or: 0.152 in Moment mW: 0.0000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: Fp= 90,000 psi Side member: Douglas Fir-Larch(&0.50) Main member: Steelstrap/clip Sidememberthickness: t.= 1.000 in Main member thickness: t.= 0.048 in Side member dowel be ring strngth: F. = 4,650 psi Main member dowel bearing strength: F,. to 61,850 psi Side member dowel bearing length: I. = 1.000 in Main member dowel bearing length: I. = 1.140 in Mode I. Mode I, Mode II Mode 111. Mode III, Mode IV _ qm= 117521bs/in qs= 884 lbs/in A: 0.0003 A: 0.00059 A: 0.00033 A: 0.0006 P= 13397 lbs P= 88416s 8: 1.07 8: 057 8: 0.5 8: O.ODD Ka= 2.400 Kr,= 2AD0 C:-4038.9 C.-3864.9 d -267.7 C: -93.6 Z.= 5582 lb. Z,= 366 lb. P= 2287 lbs Me= 46.8 in-lbs Mm= 46.8 in -Its Ka= 2.400 P= 21261be P= 420 lbs P= 392 lbs Min. Design value: Z= 163 lbs Z= 953 lbs Ko= 2.400 Ka= 2AD0 KD= 2.400 Duration Factor: Ca= 1.6 Z= 886 lbs Z= 175 lbs Z= 163 lbs Allowble Design Value (ZCO: Z'= 262 Ibs/armhor Fastener type: 1/4" 1TTV Tapcon N.O.A. 16-1222.06 Substrate: Hollow block Minimum embedment 1.25 in Edge distance: 4.00 in Tabulated shear design value: Z = 202 Ibs Edge distance: 2.00 in Tabulated shear design value Z = 161 Ibs Actual edge distance: 2.50 in Reduction factor: 0.85 Spacing: 4.00 in Tabulated shear design value: Z = 202 Ibs Spacing: 2.00 in Tabulated shear design value: Z = 164 Ibs �� t5 • �9 // Actual spacing: 3.00 in Reduction factor: 0.91 •' , Allavnble Design Value (Lf.rra): Z'= - 155 Ibs/michor - \ ~' \r`� E NSF •s'� Minimum anchor capacity: 155 Ibs/ano:hor =*• TrsyAT �r et •. /J w l Note: Anchors wlfh Ne Want eapaGyfs uaetllorealeuladona to qua My anchors wIN hlghereapaclty. r A 0 F ,' Anchor ealeuladons, minimum required anchors /Q • P . � 36.38 a Design pressure: 85.0 psf ��F� �10R10 . GN� Y 79.25 At '1 of 2 A4ax. Anchor -a- Area Load Ind. Cap. Qty Load Zane (lbs) (in) O.C. Wsult (in) (lbs) Obs) Ar 2.3 195 N/A N/A 155 2 98 OK Ae 7.7 656 fi.00 18.00 155 5 131 OK Luis R. Lomas P.E. FL No.: 62514 5/2/2017 L. Roberto Lomas P.E. 1432 Woodford Rd. Manufacturer: Masonite Lewi.Wle, NC 27023 Report #: 514010 43a688-0609 Date: 05/0112017 rllomasfa)Idomasoa com Anchor Locations: i 38 18.19 6.00 TYR 6.00 TVP. 1 l i 6.00 Installation instructions. 1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 112" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 4. ALL FASTENERS TO BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI .052' THICK MINIMUM 6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN. 2of2 ��J.••�EN•.q *. c,51 TAT OF OR VD.Vt' 0ONAt11E�G`�� Luis R. Lomas P.E. FL No.: 62514 5/2/2017