Loading...
HomeMy WebLinkAboutPRODUCT EVALUATION REPORT12rBUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 398 East Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buiIdingdrops.com Product Evaluation Report SCANNED BY Of St. Lucie County Silver Line Building Products Series 70 Model 2127 — Extruded Vinyl Single Hung Window (Non -Impact) for Florida Product Approval FL# FL19715 Report No. 4805 Current Florida Building Code Method: 1— D (Engineering Evaluation) Category: Windows Sub — Category: Single Hung Product: Series 70 Single Hung Window Material: PVC Product Dimensions: See Installation Instructions, SWD010 Prepared for: Silver Line Building Products One Silverline Dr. North Brunswick, NJ 08902 Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer N 73778 Date:12/15/2017 Contents: Evaluation Report Pages 1-4 Digitally signed by Hermes F. Norero, P.E. Reason: I am approving this document Dale: 2017.12.18 18:32:10 -05'00' ``,%%S III rr0� r� ` A0_ 7 -o•. T T tY = <u Al- Herme?o P.E. Florida No. 73778 BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 Manufacturer: Silver Line Building Products Product Category: Windows Product Sub -Category: Single Hung Compliance Method: State Product Approval Method (1)(d) Product Name: Series 70 Single Hung Window FL#: FL19715 Date: 12/15/2017 Report No: 4805 Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Silver Line Building Products based on Method ld of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission. Limits of Use: Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Current Florida Building Code. See Installation Instructions SWD010, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the Current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the Current Florida Building Code and does require an impact resistant covering. 4. Site conditions that deviate from the details of drawing SWDO10 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions SWDO10 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 4 BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 Quality Assurance: Performance Standards: Referenced Data: FL#: FL19715 Date: 12/15/2017 Report No: 4805 The manufacturer has demonstrated compliance of window products in Accordance with the Florida Building Code and State Rules for manufacturing under a quality assurance program audited by an approved quality assurance entity through Window and Door Manufacturers Association (FBC Organization #: QUA2515). The product described herein has been tested per: • TAS 202-94 • ASTM E330-02 • AAMA/WDMA/CSA101/I.S.2/A440-08/11 1. Product Testing performed by Testing Evaluation Laboratories, Inc. (FBC Organization # TST4317) Report: Dated: TEL01410311 12/15/2010 2. Quality Assurance Window and Door Manufacturers Association (FBC Organization #: QUA2515) 3. PVC profiles meet requirements of WDMA/Hal]Mark WD-61 in accordance with AAMA 303 Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 4 /(tBUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 Installation: 1. Approved anchor types and substrates areas follows: Nailing Fin Installation: FL#: FL1971S Date: 12/15/2017 Report No:4805 A. For two by (2X) wood frame substrate (Min. S.G. = 0.55), use #8 PH Wood Screw OR 11 Gauge Roofing Nails OR 30d Common Nails type wood frame anchors of sufficient length to achieve minimum embedment of 1.50" into wood framing. B. For steel stud substrate (Min 18 Ga., Fy = 33 ksi), use #8 TEK PH or HWH Screw type steel stud anchors of sufficient length to achieve minimum 3 threads penetration beyond steel structure. Through Frame Installation: A. For two by (2X) wood buck substrate (Min. S.G. = 0.55), use #10 PH Wood Screw type installation anchors of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. B. For concrete (Min. fc = 3000 psi) or masonry (Conforms to ASTM C90) substrate where one by (1X), non-structural, wood bucking is employed, use 3/16" diameter ITW HWH Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For concrete (Min. fc = 3000 psi) or masonry (Conforms to ASTM C90) substrate where wood bucking is NOT employed, use 3/16" diameter ITW HWH Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. D. For steel stud substrate (Min 18 Ga., Fy = 33 ksi), use #10 TEK PH or HWH Screw type steel stud anchors of sufficient length to achieve minimum 3 threads penetration beyond steel structure. Refer to Installation Instructions (SWD010) for anchor spacing and more details of the installation requirements. Design Pressure: Refer to Installation Instructions (SWD010) for anchor spacing and more details of the installation requirements. Hermes F. Norero, P.E. Florida No. 73778 Page 4 of 4