HomeMy WebLinkAboutD.O.H. PAPPERWORKSTATE OF FLORIDA
DEPARTMENT OF AEALTA
ONSITE SEWAGE TREATMRNT AND DISPOSAL
SYSTEM
2
F
,.CONSTRUCTION PERMIT FOR:
,I APPLICANT: CJ & Amber Frade
OSTDS New
PERMIT #:56-SF-1990379
APPLICATION #:AP1433591
DATE PAID:
FEE PAID:
SCANNEDzczxPT #:
BY DOCUMENT #: PR1253880
St. Lucie Countv.%,
PROPERTY ADDRESS: TBD Brocksmith Rd Fort.Plerce, Fl. 34945 — —
LOT: 3 BLOCK: SUBDIvIsION: Drawdy/Brocksmith Rd
PROPERTY ID #: 2329-502-0008-000-3 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER]
[OR TAX ID NUMBER]
SYSTEM MOST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION
381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE
SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS,
WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE TEE APPLICANT TO MODIFY THE
PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE HULL AND VOID.
ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL,
STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY.
SYSTEM DESIGN AND SPECIFICATIONS
T [ 1,050 ] GALLONS / GPD Septic new CAPACITY
A [ ] GALLONS / GPD N/A CAPACITY
N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS]
K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 ERS #Pumps [ ]
D [ 500 ] SQUARE FEET Drainfield new SYSTEM
R [ ] SQUARE FEET N/A SYSTEM
A TYPE SYSTEM: [ ] STANDARD [ ] FILLED PC] MOUND [ ]
I CONFIGURATION: [x] TRENCH' [ ] BED [ ]
N
F LOCATION OF BENCHMARK: �IVIH9�OB11 in fence post; S1Npioperty'.'co`m r�`
I ELEVATION OF PROPOSED SYSTEM SITE [ 10.00][ INCHES FT ][ABOVE HELOW BENCHMARK/REFERENCE POINT
E BOTTOM OF DRAINFIELD TO BE [ 1.00 ][ INCHES FT ][ABOVE iBELOW BENCHMARK./REFERENCE POINT
L
D FILL REQUIRED: 127.001 INCHES EXCAVATION REQUIRED: [ ] INCHES
?he system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of
°'* 400 gpd.
rf'i. �
E
R
SPECIFICATIONS BY: Brian J Ing TITLE: Environmental Specialist II
APPROVED BY: TITLE: Environmental Specialist II CHD
Brig ,T I}I
DATE ISSUED: 09/25/2019 EXPIRATI N&F03/25/2021
DR 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, PAC Page 1 of 3
v 1.1.4 AP1433591 SE1202097
NOTICE OF RIGHTS
A party whose substantial interest is affected by this order may petition for an
administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such
proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for
administrative hearing must be in writing and must be received by the Agency Clerk for the
Department, within twenty-one (21) days from the receipt of this order. The address of the
Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency
Clerk's facsimile number is 850-413-8743.
Mediation is not available as an alternative remedy.
Your failure to submit a petition for hearing within 21 days from receipt of this order will
constitute a waiver of your right to an administrative hearing, and this order shall become a'final
order.
Should this order become a final order, a party who is adversely affected by it is entitled
to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are
governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced
by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a
second copy, accompanied by the filing fees required by law, with the Court of Appeal in the
appropriate District Court. The notice must be filed within 30 days of rendition of the final order.
H
PAYING ON:
RECEIVED FROM:
~ PAYMENT FORM:
St. Lucie County Health Department
5150 NW Milner Dr Port Saint Lucie, FL 34983
a:56-SF-1990379 BILLooca:56-BID-4415046 CONSTRUCTION APPLICATION 0: AP1433591
Upstate Bldrs AMOUNT PAID: $ 660.00
CHECK 5150 PAYMENT DATE: 09/16/2019
MAIL TO: CJ & amber Frade
FACILITY NAME:
PROPERTY LOCATION:
TBD Brocksmith Rd
Fort Pierce, FL 34945
8
Lot: Block:
Property ID: 2329-502-0008-000-3
EXPLANATION or DESCRIPTION:
QUANTITY
FEE
128 - OSTDS Construction System Inspection Research Fee
1
$
5.00
-1 - Surcharge (All)
1
$
45.00
-1 - OSTDS New Permit Surcharge
1
$
100.00
-1 - OSTDS Construction Application and Plan Review,New
1
$
100.00
123 - OSTDS Construction Site Evaluation
1
$
115.00
126 - OSTDS Construction Permit (New or Mod, Amendment)
1
$
55.00
1-27 - OSTDS Construction System Inspection
1
$
75.00
133 - OSTDS Construction Reinspection
1
$
50.00
-1 - Well Construction
1
$
115.00
4
RECEIVED BY: MontanezNM AUDIT CONTROL NO. 56-PID-4134021
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL
SYSTEM
APPLICATION FOR CONSTRUCTION PERMIT
kPPLICATION FOR:
WEu No.59-aag4�
PERMIT NO-5 - 3 17
9
DATE PAID: MUM
FEE PAID: Eb
RECEIPT N:
6lD- uu150 tip —
New System [ ] Existing System [ ] Holding Tank [ ] Innovative
[ ] Repair [ ] Abandonment. [ ] Temporary [ ]
APPLICANT: CJ & Amber Frade
AGENT: Upstate Builders, Inc.
MAILING ADDRESS: 6650 3rd Place SW, Vero Beach, FL 32968
TELEPHONE: 772-201-8181
TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED
BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE
APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR
PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER' PROVISIONS.
PROPERTY INFORMATION
LOT: 8 BLOCK: -
PROPERTY ID (): 2329-502-0008-000-3
DrawdyBrocksmith Road S/D PLATTED: 2017
ZONING: Res I/M OR EQUIVALENT: [ No ]
PROPERTY SIZE: 5.55 ACRES WATER SUPPLY: [ �] PRIVATE PUBLIC [ ]<=2000GPD [ ]>2000GPD
IS SEWER AVAILABLE AS PER 381.0065, FS? [ No ] DISTANCE TO SEWER: n/a FT
PROPERTY ADDRESS: TBD Brocksmith Road
DIRECTIONS TO PROPERTY: -4,500 feet north of the intersection of Brocksmith Road and Okeechobee Road (SR 70)
BUILDING INFORMATION
Unit Type of
No Establishment
1 Single Family Residential
2
3
4
[ ✓'] RESIDENTIAL [ ] COMMERCIAL
No. of Building Commercial/Institutional System Design
Bedrooms Area Sqft Table 1, Chapter 64E-6, FAC
4 2,574
[ ] Floor/Equipment Drains [ ] Other (Specify)
SIGNATURE:
DH 4015, 08/09 (Obsoletes previous editions which may not be used)
Incorporated 64E-6.001, FAC
�C/
DATE: 9 / z'�/
Page 1 of 4
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ON§ITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
SITE EVALUATION AND SYSTEM SPECIFICATION
APPLICANT: CJ & Amber Frade
,CONTRACTOR / AGENT: Upstate Bldrs
-LOT: 8 BLOCK:
' SUBDIVISION:
ID#:
APPLICATION # AP1433591
PERMIT # 56-SF-1990379
DOCUMENT # SE1202887
TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTEER QUALIFIED PERSON. ENGINEERS MUST PROVIDE
REGISTRATION NUMBER AND SIGN AND SEAL HACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS.
PROPERTY SIZE CONFORMS TO SITE PLAN: IX]YES [ ]NO NET USABLE AREA AVAILABLE: 5.55 ACRES
TOTAL ESTIMATED SEWAGE FLOW: 400 GALLONS PER DAY [ RESIDENCES -TABLET / OTHER -TABLE 2 ]
AUTHORIZED SEWAGE FLOW: 8325.00 GALLONS PER DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE ]
UNOBSTRUCTED AREA AVAILABLE: 2000.00 SQFT UNOBSTRUCTED AREA REQUIRED: 1000.00 SQFT
BENCHMARK/REFERENCE POINT LOCATION:
ELEVATION OF PROPOSED SYSTEM SITE 10.00 I TNCHES / FT ] [ ABOVE /IBELOW J1'BENCHMARK/REFER=CE POINT
THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES
SURFACE WATER: 100 FT DITCHES/SWALES: 100 FT NORMALLY WET: [ ]YES IX]NO
WELLS: PUBLIC: FT LIMITED USE: PT PRIVATE: 100 FT - NON -POTABLE: FT
BUILDING FOUNDATIONS: 5 FT PROPERTY LINES: 40 FT POTABLE WATER LINES: 30 FT
SITE SUBUECT TO FREQUENT FLOODING? [ ]YES [X]NO 10 YEAR FLOODING? [ ]YES [X]N01
10 YEAR FLOOD ELEVATION FOR SITE: FT MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD
AnTT. PPnFTT.R TT1 Mn MTnN CT,"A T
USDA SOIL SERIES:
Munsell #/Color
Texture
Depth
I OYR 42
Sand
0 To 6
10YR 5/1
Sand -
6 To 12
1OYR 52
Sand
12To21
10YR 5/8
CMN/PRM RF
15 To 21
10YR 5/4
Sand
21 To 35
1 OYR 6/4
Sand
24 To 35
10YR'5/1
Sandy Clay Loam
35 To 55
1 OG 611
Sandy Clay Loam
55 To 72
ADTT. PRO£TT.£. TN£nR TTON STIR 2
USDA SOIL SERIES:
Munsell #/Color
Texture
Depth
I OYR 42 -
Sand
0 To 6
1 OYR 52
Sand
6 To 25
1 OYR 518
CMN/PRM RF
17 To 25
10YR 5/4
Sand
25 To 36
1 OYR 613
Sand
26 To 36
1 OG 6/1
Sandy Clay Loam
36 To 72
OBSERVED WATER TABLE: 35.00 INCHES I ABOVE /. BELOW ] EXISTING GRADE TYPE: APPARENT ]
.ESX1MhTED WET SEASON WATER TABLE ELEVATION: 15 INCHES [ ABOVE / BELOW ] EXISTING GRADE
HIGH WATER TABLE VEGETATION: I ]YES EX ]NO MOTTLING: IX]YES I ]NO DEPTH: 15.00 INCHES
SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Sand/0.80 DEPTH OF EXCAVATION:
DRAXNFI= CONFIGURATION: .[X ] TRENCH [ ] BED [ ] OTHER (SPECIFY)
7 REMARKS/ADDITIONAL CRITERIA
IT determined using USDA WSS and soil borings.
t5/8 CMN PROM RF mottling in 10YR5/2 matrix,>20A starting at 15" in S131.
10" below SM. SB2 9" below SM.
SITE EVALUATED BY: 67> "'`J
Ingram, Brian
DR 4015, 08109 (Obsoletes previous editions w
ronmental Specialist B) (ENVIRONMENTAL HEALTH)
not be used) Incorporated: 64E-6.001, FAC
INCHES
DATE : 09120/2019
Page 3 of 4
AP1433591 EID1990379 v 1.0.2
Property Card
5(,-5r--(49C.37.� 5,�- 211 y1
Michelle Franklin, CFA
— Saint Lucie County Property Appraiser —AII rights reserved.
Property Identification
Site Address: Parcel ID:2329-502-0008- Account#:182598 Secfrown/Range:
BROCKSMITH RD 000-3
29/35SI39E
Map ID: 23/29N Zoning:
Use Type: 0000 Jurisdiction: Saint Lucie
County
Ownership
Legal Description
Amber Lynn Allen-Frade
DRAWDYBROCKSMITH ROAD SUBDIVISION (PB 75-23)
Carlos Jorge Leonardi Frade - -
LOT 8 (5.55 AC-241,758 SF) — -
626 SE Damask AVE
Port St Lucie, FL 34983
Current Values
Historical Values 3-year
Just/Market: $116,600 Assessed:
$116,600 Year Just/Market Assessed Exemptions Taxable
Exemptions: $0 Taxable:
$116,600 2019 $116,600 $116,600 $0 $116,600
2018 $116,550 $1,526 $0 $1,526
Sale History
Date Book/Page Sale Code Deed Grantor
02-12-2019 4232 / 2912 0111 WD Allen Arthur H
10-24-2017 4062 / 0593 0001 WD Drawdy (TR) Troy W
Total Areas
FinishedfUnder Air
(SF):
Gross Sketched Area
(SF):
Land Size (acres):
Land Size (SF):
Total Building Count:
Price
$100
$140,000
0
0
5.55
241,758
Special Features and Yard Items
Type Qty Units Year Bit
- - All information is believed to be correct at this time, but is subject to change and is provided without any warranty.
® Copyright 2019 Saint Lucie County Property Appraiser. All rights reserved.
J
Page 1 of 1
tttps://paslc-dev.org/RECard/ 9/16/2019
S I � u>✓ ^7
�. �' • tea;..' �<.4...... ... '.. �� . �I
.ills R ......
.all•�i� '?9• •
rNIMP#48
Ix.
13, _
Is+ 38
r44 41
aow
..r1 7 -will'
L j11,
Y � t ttFpF:
f —^C
,. -
Custom Soil Resource Report
St. Lucie County, Florida
38—Riviera fine sand, 0 to 2 percent slopes
Map Unit Setting
National map unit symbol: 2tzw2
Elevation: 0 to 80 feet
Mean annual precipitation: 44 to 59 inches.
-Mean annual air temperature: 68 to 77 degrees F
Frost -free period. 350 to 365 days
Farmland classification: Farmland of unique importance
Map Unit Composition
Riviera and similar soils. 80 percent
Minor components., 20 percent
Estimates are based on observations, descriptions, and transacts of the mapunit.
Description of Riviera
Setting
Landform: Flats on marine terraces, drainageways on marine terraces
Landform position (three-dimensional): Tread, talf, dip
Down -slope shape: Linear
Across -slope shape: Linear, concave
Parent material., Sandy and loamy marine deposits
Typical profile
A - 0 to 6 inches: fine sand
E - 6 to 28 inches: fine sand
BVE - 28 to 32 inches: fine sandy loam
Big - 32 to 42 inches. sandy clay loam
C - 42 to 80 inches. fine sand
Properties and qualities
Slope: 0 to 2 percent
Depth to restrictive feature: More than 80 inches
Natural drainage class. Poorly drained
Runoff class. Very high
Capacity of the most limiting layer to transmit water (Ksat): Moderately high to
high (0.60 to 6.00 in/hr)
Depth to water table. About 3 to 18 inches
Frequency of flooding: None
Frequency of ponding. None
Salinity, maximum in profile: Nonsaline to very slightly saline (0.0 to 2.0
mmhos/cm)
Sodium adsorption ratio, maximum in profile: 4.0
Available water storage in profile: Moderate (about 6.0 inches)
Interpretive groups
Land capability classification (irrigated): None specified
Land capability classification (nonirrigated): 3w
Hydrologic Soil Group: A/D
Forage suitability group: Sandy over loamy soils on flats of hydric or mesic
lowlands (G155XB241 FL)
Othervegetative c/ass cation: Slough (R155XY011FL)
10
Custom Soil Resource Report
Hydric soil rating. Yes
Minor Components
Wabasso
Percent of map unit., 8 percent
Landform: Flatwoods on marine terraces
Landform position (three-dimensional): Tread, talf
Down -slope shape: Convex, linear
Across -slope shape: Linear
Other vegetative classification: South Florida Flatwoods (R155XY003FL)
Hydric soil rating: No
Hallandale
Percent of map unit., 4 percent
Landform: Flatwoods on marine terraces
Landform position (three-dimensional): Tread, talf
Down -slope shape: Linear
Across -slope shape: Linear
Other vegetative classification: South Florida Flatwoods (RI55XY003FL)
Hydric soil rating: Yes
Pinellas
Percent of map unit: 4 percent
Landform: Flatwoods on marine terraces
Landform position (three-dimensional): Tread, tall
Down -slope shape: Convex, linear
Across -slope shape: Linear
Other vegetative classification: Cabbage Palm Flatwoods (R155XY005FL)
Hydric soil rating: No
Floridana
Percent of map unit., 2 percent
Landform: Depressions on marine terraces
Landform position (three-dimensional): Tread, dip
Down -slope. shape: Concave, linear
Across -slope shape: Concave, linear
Other vegetative classification: Freshwater Marshes and Ponds (R155XY010FL)
Hydric soil rating. Yes
Oldsmar
Percent of map unit. 2 percent
Landform: Flatwoods on marine terraces
Landform position.(three-dimensional): Talf
Downslope shape: Convex, linear
Across -slope shape: Linear
Other vegetative classification: South Florida Flatwoods (R155XY003FL)
Hydric soil rating. No
11
Custom Soil Resource Report
48—Wabasso sand, 0 to 2 percent slopes
Map Unit Setting
National map unit symbol. 2svyr
Elevation. 0 to 70 feet
Mean annual precipitation: 46 to 55 inches
Mean annual air temperature: 70 to 77 degrees F
Frost -free period., 355 to 365 days
Farmland classification: Farmland of unique importance
Map Unit Composition
Wabasso and simflarsoils 85 percent
Minor components. 15 percent
Estimates are based on observations, descriptions, and transects of the mapunit.
Description of Wabasso
Setting
Landform: Flatwoods on marine terraces
Landform position (three-dimensional): Tread, talf
Down -slope shape: Linear
Across -slope shape: Linear
Parent material: Sandy and loamy marine deposits
Typical profile
A - 0 to 6 inches. sand
E - 6 to 25 inches. sand
Bh - 25 to 30 inches: sand
Big - 30 to 58 inches., sandy clay loam
Cg - 58 to 80 inches., loamy sand
Properties and qualities
Slope: 0 to 2 percent
Depth to restrictive feature: 9 to 50 inches to strongly contrasting textural
stratification
Natural drainage class: Poorly drained
Runoff class. Very high
Capacity of the most limiting layer to transmit water (Ksat): Moderately low to
moderately high (0.06 to 0.20 in/hr)
t Depth to water table: About 6 to 18 inches
Frequency of flooding: None
Frequency ofponding: None
Calcium carbonate, maximum in profile: 5 percent
Salinity, maximum in profile: Nonsaline to very slightly saline (0.0 to 2.0
mmhoslcm)
Sodium adsorption ratio, maximum in profile: 4.0
Available water storage in profile: Very low (about 1.4 inches)
Interpretive groups
Land capability classification (irrigated): None specified
12
Custom Soil Resource Report
Land capability classification (noninigated): 3w
Hydrologic Soil Group: CID
Forage suitability group: Sandy soils on flats of mesic or hydric lowlands
(G155XB141FL)
Other vegetative classification: South Florida Flatwoods (R155XY003FL)
Hydric soil rating. No
Minor Components
Hallandale —
Percent of map unit: 6 percent
Landform: Flatwoods on marine terraces
Landform position (three-dimensional): Tread, talf
Down -slope shape: Linear
Across -slope shape: Linear
Other vegetative classification: South Florida Flatwoods (R155XY003FL)
Hydric soil rating: Yes
Boca
Percent of map unit. 5 percent
Landform: Drainageways on marine terraces, flats on marine terraces
Landform position (three-dimensional): Tread, dip, talf
Down -slope shape: Linear, convex
Across -slope shape. Linear, concave
Ecological site: South Florida Flatwoods (R155XY003FL)
Other vegetative classification: South Florida Flatwoods (R155XY003FL)
Hydric soil rating: Yes
Pineda
Percent of map unit: 4 percent
Landform: Drainageways on marine terraces, flats on marine terraces
Landform position (three-dimensional): Tread, dip, talf
Down -slope shape: Linear
Across -slope shape: Concave, linear
Other vegetative classification: Slough (R155XY011 FL)
Hydric soil rating: Yes
13
i
os
�: aipl -- I I �� ° •� s I
1 t