Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 RECEIVED DEC 101619 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSUnty . Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: FRADE RESIDENCE SCANNED Builder Name: �''vv��,, y Street: BY Permit Office: ST LUCIE COUNTY SCAN City, State, Zip: FORT PIERCE, FL, St. Lucie Courmt n Number. NEI Owner: `Y Jurisdiction: ST LUCIE COUNTY .. Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or epsting New (From Plans) 9. Wall Types (2931.3 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- E# Insul, Erderior R=4.1 2931.30 ft' b. N/A R= ft' 3. Number of units, N multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 4 d. N/A R= ft' 10. Ceiling Types (2574.0 sgfL) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2574.00 ft2 6. Conditioned floor area above grade (W) 2574 b. N/A R= ft' Conditioned floor area below grade (ft-) 0 c. N/A R= ft' 11. Ducts R fF 7. Windows(289.0 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: LAUNDRY 6 150 a. U-Factor. Sgl, U=0.65 153.00 ft' b. Sup: Attic, Ret: Attic, AH: Attic 6 125 SHGC: SHGC=0.25 b. U-Factor: Sgl, U--0.65 136.00 ft' 12. Coding systems kBtulhr Efficiency SHGC: SHGC=0.30 a. Central Unit 35.2 SEER:16.00 b. Central Unit 18.8 SEER:16.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 1.500 ft. Area Weighted Average SHGC: 0.274 14. Hot water systems a. Electric Cap: 50 gallons oor T es 4f 8. Fl � ( 257.0 sqt.) Insulation Area I EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2574.00 ft' b. Conservation features b. N/A R= fF None c. N/A R= fN 15. Credits None ~Glass/Floor Area: 0.112 Total Proposed Modified Loads: 89.41 PASS Total Baseline Loads: 92.14 I hereby certify that the plans and specifications covered by Review of the plans and by this F EUE SPq? this calculation are in compliance with the Florida Energy specifications covered y� ;AO Code. calculation indicates compliance with the Florida Energy Code. �p PREPARED BY: t w Before construction is completed DATE: 11-18-19 this building will be inspected for compliance with Section 553.908 } O l X. I hereby certify that this building, as designed, is in compliance Florida Statutes. With the Florida Energ o n CAD WE OWNER/AGE NT, - BUILDING OFFICIAL: DATE: )- 9 r - r DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). RECEIVED DEC 10 2019 Permitting Department 11/18/201912:04 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FleRes2017 FBC 6th Edition (2017) Compliant Software St. Lucie CouRavge 1 of 7 e FORM R406-2017 INYU I SUMMAKY GHLUKLI, l Ktl'UKT PROJECT Titre: FRADE RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2574 Lot # Owner Name: Total Stories: 1 BlocklSubdivision: #of Units: 1 Worst Case: No PlatBook: � Builder Name: Rotate Angle: 0 Street Permit Office: ST LUCIE COUNTY Cross Ventilation: No County. St Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, - Family Type: Single-family FL, New/F)dsting: New (From Plans) i Comment: - - -- - CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 1807 21539.3 2 AHU 2 767 7133.1 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MTOILET 40 372 No 0 1 Yes Yes Yes 2 M BATH 158 1469A No 0 1 Yes Yes Yes 3 MASTERBEDROO 288 2966.4 No 0 1 1 Yes Yes Yes 4 M WIC 132 1227.6 No 0 1 Yes Yes Yes 5 HALL 48 446.4 No 0 1 No Yes Yes 6 KITCHEN 234 3276 Yes 0 1 No Yes Yes 7 PANTRY 84 781.2 No 0 1 Yes Yes Yes 8 NOOK 110 1540 No 0 1 Yes Yes Yes 9 DINING ROOM 154 2156 No 0 1 Yes Yes Yes 10 LAUNDRY 111 1032.3 No 0 1 No Yes Yes 11 FOYER 72 1008 No 0 1 Yes Yes Yes • 12 FAMILY ROOM 376 5264 No 0 1 Yes Yes Yes 13 CLST 2 14 130.2 No 0 1 No Yes Yes ' 14 BEDROOM2 151 1404.3 No 0 1 1 Yes Yes Yes 15 BEDROOM3 165 1534.5 No 0 1 1 Yes Yes Yes 16 HALLWAY 40 372 No 0 1 No Yes Yes 17 WIC 3 48 446.4 No 0 1 Yes Yes Yes 18 BATH 2 36 334.8 No 0 1 No Yes Yes 19 SINKS 2 36 335 No 0 1 No Yes Yes 20 WIC 42 390.6 No 0 1 No Yes Yes 21 BATH 3 54 502.2 No 0 1 Yes Yes Yes 11/181201912:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil to Finished Cooled Heated 22 BEDROOM 4 181 1683.3 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation M TOILET 13 ft 0 40 ft' — 1 0 0 2 Slab -On -Grade Edge Insulation M BATH 16 ft 0 158 fP — 1 0 0 3 Slab -On -Grade Edge Insulation MASTER BEDRO 24 ft 0 288 f' — 1 0 0 4 Slab -On -Grade Edge Insulation M WIC 12 ft 0 132 ft' — 1 0 0 5SIab-On-Grade Edge Insulation HALL 1 ft 0 48 ft' — 1 0 0 6 Slab -On -Grade Edge Insulation KITCHEN 1ft 0 234ft — 1 0 0 7 Slab -On -Grade Edge Insulation PANTRY E ft 0 84 ft' — 1 0 0 8 Slab -On -Grade Edge Insulation NOOK 18ft 0 110 fN — 1 0 0 9 Slab -On -Grade Edge Insulation DINING ROOM 16ft 0 154 fN — 1 0 0 10Slab-On-Grade Edge Insulation LAUNDRY 1 ft 0 111 ft, — 1 0 0 11Slab-On-Grade Edge Insulation FOYER Bit 0 72 ft- — 1 0 0 12SIab-On-Grade Edge Insulation FAMILY ROOM 19 ft 0 37\6 fN — 1 0 0 13SIab-On-Grade Edge Insulation CLST 2 1 ft 0 14 ft' — 1 0 0 14SIab-On-Grade Edge Insulation BEDROOM 2 16 ft 0 151 ft' — 1 0 0 15Siab-O -Grade Edge Insulation BEDROOM3 26 ft 0 165 ft- — 1 0 0 16SIab-On-Grade Edge Insulation HALLWAY 1 ft 0 40 ft' _ 1 0 0 17SIab-On-Grade Edge Insulation WIC 3 loft 0 48 ft' — 1 0 0 18SIab-On-Grade Edge Insulation BATH 2 1 ft 0 36 ft' — 1 0 0 19SIab-On-Grade Edge Insulation SINKS 2 1 ft 0 36 W _ 1 0 0 20SIab-On-Grade Edge Insulation WIC 1ft 0 42 fP — 1 0 0 21SIab-On-Grade Edge Insulation BATH 3 6 ft 0 54 ft' _ 1 0 0 22SIab-On-Grade Edge Insulation BEDROOM 4 37 ft 0 181 fP — 1 0 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2879 ft' Oft' Ught N 0.6 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS - IRCC 1 Full attic Vented 150 2574 ft- N N FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic(Vented) MTOILET 30 Blown 40 ft- 0.1 Wood 2 Under Attic (Vented) MBATH 30 Blown 158 ft' 0.1 Wood 3 Under Attic (Vented) MASTER BEDRO 30 Blown 288 ft' 0.1 Wood _ 4 Under Attic (Vented) M W IC 30 Blown 132 ft' 0.1 Wood _ 5 Under Attic (Vented) HALL 30 Blown 48 ft' 0.1 Wood _ 6 Under Attic (Vented) KITCHEN 30 Blown 234 ft' 0.1 Wood 7 Under Attic (Vented) PANTRY 30 Blown 84 ft' 0.1 - Wood _ 8 Under Attic (Vented) NOOK 30 Blown 110 ft' 0.1 Wood 9 Under Attic (Vented) DINING ROOM 30 Blown 154 ft' 0.1 Wood _ 10 Under Attic (Vented) LAUNDRY 30 Blown 111 ft' 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 72 ft' 0.1 Wood 12 Under Attic (Vented) FAMILY ROOM 30 Blown 376 ft' 0.1 Wood 13 Under Attic (Vented) CLST2 30 Blown 14 ft' 0.1 Wood 14 Under Attic (Vented) BEDROOM 2 30 Blown 151 ft' 0.1 Wood 15 Under Attic (Vented) BEDROOM3 30 Blown 165 ft' 0.1 Wood 16 Under Attic (Vented) HALLWAY 30 Blown 40 ft= 0.1 Wood 17 Under Attic(Vented) WIC 30 Blown 48 ft' 0.1 Wood 18 Under Attic (Vented) BATH 2 30 Blown 36 ft' 0.1 Wood 19 Under Attic (Vented) SINKS 2 30 Blown 36 ft' 0.1 Wood 2Q Under Attic (Vented) WIC4 30 Blown 42 ft' 0.1 Wood 21 Under Attic (Vented) BATH 3 30 Blown 54 fF 0.1 Wood 22 Under Attic (Vented) BEDROOM 4 30 Blain 181 ft' 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belau Space 1 N Exterior Concrete Block -Ext lnsulM TOILET 4.1 5 0 9 4 46.7 ft' 0 0 0.6 0 _ 2 W Exterior Concrete Block- Ext InsulM TOILET 4.1 8 0 9 4 74.7 ft' 0 0 0.6 0 3 N Exterior Concrete Block- Ext Insul M BATH 4.1 6 0 9 4 56.0 ft' 0 0 0.6 0 _ 4 W Exterior Concrete Block - Ext Insul M BATH 4.1 10 0 9 4 93.3 fN 0 0 0.6 0 _ 5 N Exterior Concrete Block- Fed Ins&lASTER BE 4.1 16 0 10 4 165.3 ft' 0 0 0.6 0 -6 E Exterior Concrete Block - Ext InsdNASTER BE 4.1 8 0 10 4 82.7 ft- 0 0 0.6 0 7 W Exterior Concrete Block- Ext Insul M W IC 4.1 12 0 9 4 112.0 ft' 0 0 0.6 0 _ _ 8 S Exterior Concrete Block- Ext Insul M W IC 4.1 11 0 9 4 102.7 ft' 0 0 0.6 0 _ 9 S Exterior Concrete Block- Ext Insul HALL 4.1 4 0 9 4 37.3 ft- 0 0 0.6 0 10 `-11 W Exterior Concrete Block- Ext Insul HALL 4.1 3 0 9 4 28.0 fP 0 0 0.6 0 W Exterior Concrete Block - Ext Insul KITCHEN 4.1 6 0 14 0 84.0 it- 0 0 0.6 0 _ 12 S Exterior Concrete Block - Ext Insul PANTRY 4.1 6 0 9 4 56.0 ft' 0 0 0.6 0 13 W Exterior Concrete Block -Ext Insul PANTRY 4.1 14 0 9 4 130.7 ft- 0 0 0.6 0 _ 14 N Exterior Concrete Block- Ext Insul NOOK 4.1 11 0 14 0 154.0112 0 0 0.6 0 _ 15 E Exterior Concrete Block- Ext Insul NOOK 4.1 7 0 14 0 98.0 ft- 0 0 0.6 0 _ 16 E Exterior Concrete Block- Ext InsOINING ROO 4.1 5 0 14 0 70.0 ft' 0 0 0.6 0 _ 17 S Exterior Concrete Block- Ext InsOINING ROO 4.1 11 0 14 0 154.0 iN 0 0 0.6 0 18 S Exterior Concrete Block- Ext InsuILAUNDRY 4.1 10 0 9 4 93.3 ft- 0 0 0.6 0 11118/201912:04 PM EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 19 E Exterior Concrete Block-Ext InsulLAUNDRY 4.1 3 0 9 4 28.Oft- 0 0.6 0 20 -21 S Exterior Concrete Block- Ext Insul FOYER 4.1 8 0 14 0 112.0 ft' 0 0 0.6 0 N Exterior Concrete Block- Ext Ins81AMILY ROO 4.1 19 0 14 0 266.0 ft' 0 0 0.6 0 _ 22 S Exterior Concrete Block - Ext Insd3EDROOM 2 4.1 11 0 9 4 102.7 ft' 0 0 0.6 0 23 W Exterior Concrete Block- Ext InstEEDROOM 2 4.1 5 0 9 4 46.7 ft' 0 0 0.6 0 24 E Exterior Concrete Block- Ext lnsdBEDROOM3 4.1 15 0 9 4 140.0 ft' 0 0 0.6 0 25 S Exterior Concrete Block -Ext lnsd3EDROOM3 4.1 11 0 9 4 102.7 ft' 0 0 0.6 0 26 E Exterior Concrete Block- Ext Insul WIC 3 4.1 10 0 9 4 93.3 ft' 0 0 0.6 0 _ 27 E Exterior Concrete Block - Ext Insul BATH 3 4.1 6 0 9 4 56.0 ft' 0 0 0.6 0 _ 28 N Exterior Concrete Block - Ext InsZEDR00M 4 4.1 15 0 9 4 140.0 ft- 0 0 0.6 0 _ 29 E Exterior Concrete Block - Ext InsiMEDROOM 4 4.1 13 0 9 4 121.3 ft' 0 0 0.6 0 30 W Exterior Concrete Block- Ext InstSEDROOM 4 4.1 9 0 9 4 84.0 ft' 0 0 0.6 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated HALL None .2 2 8 6 8 17.8 ft' WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 N 3 Metal Low-E Single Yes 0.65 0.25 Y 6.0 ft' 1 ft 6 in 1 ft 4 in None None _ 2 W 4 Metal Low-E Single Yes 0.65 0.25 Y 6.0 ft- 1 It 6 in 1 ft4 in None None _ 3 N 5 Metal Low-E Single Yes 0.66 0.25 Y 30.0 it- 1 ft 6 in 1 it 4 In None None _ 4 E 6 Metal Law-E Single Yes 0.65 0.3 Y 40.0 ft` 1 ft 6 in 1 ft 4In None None _ 5 N 14 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft- 1 ft 6 in 1 ft 4 in None None 6 S 17 Metal _ Low-E Single Yes 0.65 0,25 Y 30.0 ft' 1 It 61n 1 ft 4 in None None 7 S 20 Metal Low-E Single Yes 0.65 0.3 Y 48.0 ft' 1 ft 6 in 1 ft 4 in None None _ 8 N 21 Metal Low-E Single Yes 0.65 0.3 Y 48.0 ft' 1 ft 6 in 1 ft 4 in None None 9 S 22 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft' 1 ft 6 in 1 ft 4 in None None _ 10 S 25 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft' 1 It 6 in 1 it 4 in None None _ 11 E 27 Metal Low-E Single Yes 0.65 0.25 Y 6.0 ft' 1 It 6 in 1 ft 4 in None None 12 E 29 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft' 1 It 6 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000495 3345.1 183.64 345.37 .196 7 11/18f201912:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COPA 17 kBtulhr 2 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Black Ducts 1 Central Unit/ Split Single SEER: 16 35.2 kBtu/hr 1056 cfm 0.8 1 sys#1 2 Central Unit/ Split Single -SEER: 16 18.8 kBtu/hr 564 cfm 0.8 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None LAUNDRY 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS —Supply— —Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 150 ft' Attic 15 ft' Default Leakage LAUNDRY (Default) c(Default) c 1 1 2 Attic 6 125 fN Attic 13 ft' Default Leakage Attic (Default) c(Default) c 2 2 TEMPERATURES Programable(rXT�]hermostat: N Ceiling Fans: Feb Mar Feb Ma Apr Apr JJan �7(� May n un 1Jul Many [X� 1Aug [X] ]Sep [ j Oct L1 Oct W Nov Nov H Dec Dec Venting [ ]Ja ( Jun 111 Jul E E 1 Aug E 1 Sep lxl Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling IWO) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78- 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Defeull(8 lbs/sq.ft. 0 ft' 0 ft 0.3 M TOILET Default(81bs/sq.ft. ft' ft 0.3 M BATH Default(8 lbs/sq.ft. ft' ft 0.3 MASTER BEDROO Default(8 lbs/sq.f. ft' ft 0.3 MWIC Default(8 lbs/sq.ft. ft' ft 0.3 HALL 11/18/2019 12:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. ft' It 0.3 KITCHEN Default(8 lbs/sq.ft. ft' It 0.3 PANTRY Default(8 lbs/sq.ft. ft' It 0.3 NOOK Default(8 lbs/sq.ft. IF ft 0.3 DINING ROOM Default(8 lbs/sq.ft. fF ft 0.3 LAUNDRY Default(8 lbs/sq.ft. fF ft 0.3 FOYER Default(8 lbs/sq.ft. ft' It 0.3 FAMILY ROOM Default(8 lbs/sq.ft. ff` It 0.3 CLST 2 Default(B lbs/sq.ft. fF It 0.3 BEDROOM 2 Default(B lbs/sq.ft. fF It 0.3 BEDROOM3 Default(B lbs/sq.ft. fF It 0.3 HALLWAY Default(8 lbs/sq.ft. fF It 0.3 WIC Default(8 lbs/sq.ft. fF R 0.3 BATH 2 Default(8 lbs/sq.ft. fF ft 0.3 SINKS 2 Default(8 lbs/sq.ft. if It 0.3 WIC4 Default(8 lbs/sq.ft. fF It 0.3 BATH 3 Default(8 lbs/s.ft. fF It 0.3 BEDROOM 4 11/18/2019 12:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 or 7 SCANNED 2017 EPL DISPLAY CARD BY St. Lucie County ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 �r The lower the Energy Performance Index, the more efficient the home. • 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location varies 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 54.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/Water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 2574 d) Room unitIPTAC EER e) Other 7. Windows, type and area - a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.274 14. Heating system: Capacity 44.0 c) Area 7c. 289.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1, e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 2. Masonry (Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I'certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: n G `p 1 Dater'=�J -/ 7 �@yy/ Address of New Home: o OC)0 J pJ 1Q UC-t 6 N'+G'City/FL Zip: FORTFr'0'P `r 11/18/2019 12:05:04 PM EnergyGaugeG USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1