HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
RECEIVED
DEC 101619
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSUnty
. Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: FRADE RESIDENCE
SCANNED
Builder Name: �''vv��,, y
Street:
BY
Permit Office: ST LUCIE COUNTY SCAN
City, State, Zip: FORT PIERCE, FL,
St. Lucie Courmt
n
Number.
NEI
Owner:
`Y
Jurisdiction: ST LUCIE COUNTY
.. Design Location: FL, Fort Pierce
County. St. Lucie (Florida Climate Zone 2 )
1. New construction or epsting
New (From Plans)
9. Wall Types (2931.3 sgft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block- E# Insul, Erderior
R=4.1 2931.30 ft'
b. N/A
R= ft'
3. Number of units, N multiple family
1
c. N/A
R= ft'
4. Number of Bedrooms
4
d. N/A
R= ft'
10. Ceiling Types (2574.0 sgfL)
Insulation Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=30.0 2574.00 ft2
6. Conditioned floor area above grade (W)
2574
b. N/A
R= ft'
Conditioned floor area below grade (ft-)
0
c. N/A
R= ft'
11. Ducts
R fF
7. Windows(289.0 sgft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: LAUNDRY
6 150
a. U-Factor. Sgl, U=0.65
153.00 ft'
b. Sup: Attic, Ret: Attic, AH: Attic
6 125
SHGC: SHGC=0.25
b. U-Factor: Sgl, U--0.65
136.00 ft'
12. Coding systems
kBtulhr Efficiency
SHGC: SHGC=0.30
a. Central Unit
35.2 SEER:16.00
b. Central Unit
18.8 SEER:16.00
c. U-Factor: N/A
ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
b. Electric Strip Heat
17.0 COP:1.00
Area Weighted Average Overhang Depth:
1.500 ft.
Area Weighted Average SHGC:
0.274
14. Hot water systems
a. Electric
Cap: 50 gallons
oor T es 4f
8. Fl � ( 257.0 sqt.)
Insulation Area
I
EF: 0.980
a. Slab -On -Grade Edge Insulation
R=0.0 2574.00 ft'
b. Conservation features
b. N/A
R= fF
None
c. N/A
R= fN
15. Credits
None
~Glass/Floor Area: 0.112
Total Proposed Modified Loads: 89.41
PASS
Total Baseline Loads: 92.14
I hereby certify that the plans and specifications covered by
Review of the plans and
by this
F EUE SPq?
this calculation are in compliance with
the Florida Energy
specifications covered
y� ;AO
Code.
calculation indicates compliance
with the Florida Energy Code.
�p
PREPARED BY: t w
Before construction is completed
DATE: 11-18-19
this building will be inspected for
compliance with Section 553.908
}
O l X.
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
With the Florida Energ o n
CAD WE
OWNER/AGE NT, -
BUILDING OFFICIAL:
DATE: )- 9 r - r
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed In accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
RECEIVED
DEC 10 2019
Permitting Department
11/18/201912:04 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FleRes2017 FBC 6th Edition (2017) Compliant Software St. Lucie CouRavge 1 of 7
e
FORM R406-2017 INYU I SUMMAKY GHLUKLI, l Ktl'UKT
PROJECT
Titre:
FRADE RESIDENCE
Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2574
Lot #
Owner Name:
Total Stories: 1
BlocklSubdivision:
#of Units:
1
Worst Case: No
PlatBook:
� Builder Name:
Rotate Angle: 0
Street
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County.
St Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FORT PIERCE,
- Family Type:
Single-family
FL,
New/F)dsting:
New (From Plans)
i
Comment:
-
-
--
-
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
AHU 1
1807
21539.3
2
AHU 2
767
7133.1
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1
MTOILET
40
372 No
0
1
Yes
Yes
Yes
2
M BATH
158
1469A No
0
1
Yes
Yes
Yes
3
MASTERBEDROO
288
2966.4 No
0
1
1
Yes
Yes
Yes
4
M WIC
132
1227.6 No
0
1
Yes
Yes
Yes
5
HALL
48
446.4 No
0
1
No
Yes
Yes
6
KITCHEN
234
3276 Yes
0
1
No
Yes
Yes
7
PANTRY
84
781.2 No
0
1
Yes
Yes
Yes
8
NOOK
110
1540 No
0
1
Yes
Yes
Yes
9
DINING ROOM
154
2156 No
0
1
Yes
Yes
Yes
10
LAUNDRY
111
1032.3 No
0
1
No
Yes
Yes
11
FOYER
72
1008 No
0
1
Yes
Yes
Yes
• 12
FAMILY ROOM
376
5264 No
0
1
Yes
Yes
Yes
13
CLST 2
14
130.2 No
0
1
No
Yes
Yes
' 14
BEDROOM2
151
1404.3 No
0
1
1
Yes
Yes
Yes
15
BEDROOM3
165
1534.5 No
0
1
1
Yes
Yes
Yes
16
HALLWAY
40
372 No
0
1
No
Yes
Yes
17
WIC 3
48
446.4 No
0
1
Yes
Yes
Yes
18
BATH 2
36
334.8 No
0
1
No
Yes
Yes
19
SINKS 2
36
335 No
0
1
No
Yes
Yes
20
WIC
42
390.6 No
0
1
No
Yes
Yes
21
BATH 3
54
502.2 No
0
1
Yes
Yes
Yes
11/181201912:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number Name
Area Volume
Kitchen Occupants
Bedrooms
Infil to Finished
Cooled
Heated
22
BEDROOM 4
181 1683.3
No 0
1
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
1 Slab -On -Grade Edge Insulation
M TOILET
13 ft
0
40 ft'
—
1
0
0
2 Slab -On -Grade Edge Insulation
M BATH
16 ft
0
158 fP
—
1
0
0
3 Slab -On -Grade Edge Insulation
MASTER BEDRO
24 ft
0
288 f'
—
1
0
0
4 Slab -On -Grade Edge Insulation
M WIC
12 ft
0
132 ft'
—
1
0
0
5SIab-On-Grade Edge Insulation
HALL
1 ft
0
48 ft'
—
1
0
0
6 Slab -On -Grade Edge Insulation
KITCHEN
1ft
0
234ft
—
1
0
0
7 Slab -On -Grade Edge Insulation
PANTRY
E ft
0
84 ft'
—
1
0
0
8 Slab -On -Grade Edge Insulation
NOOK
18ft
0
110 fN
—
1
0
0
9 Slab -On -Grade Edge Insulation
DINING ROOM
16ft
0
154 fN
—
1
0
0
10Slab-On-Grade Edge Insulation
LAUNDRY
1 ft
0
111 ft,
—
1
0
0
11Slab-On-Grade Edge Insulation
FOYER
Bit
0
72 ft-
—
1
0
0
12SIab-On-Grade Edge Insulation
FAMILY ROOM
19 ft
0
37\6 fN
—
1
0
0
13SIab-On-Grade Edge Insulation
CLST 2
1 ft
0
14 ft'
—
1
0
0
14SIab-On-Grade Edge Insulation
BEDROOM 2
16 ft
0
151 ft'
—
1
0
0
15Siab-O -Grade Edge Insulation
BEDROOM3
26 ft
0
165 ft-
—
1
0
0
16SIab-On-Grade Edge Insulation
HALLWAY
1 ft
0
40 ft'
_
1
0
0
17SIab-On-Grade Edge Insulation
WIC 3
loft
0
48 ft'
—
1
0
0
18SIab-On-Grade Edge Insulation
BATH 2
1 ft
0
36 ft'
—
1
0
0
19SIab-On-Grade Edge Insulation
SINKS 2
1 ft
0
36 W
_
1
0
0
20SIab-On-Grade Edge Insulation
WIC
1ft
0
42 fP
—
1
0
0
21SIab-On-Grade Edge Insulation
BATH 3
6 ft
0
54 ft'
_
1
0
0
22SIab-On-Grade Edge Insulation
BEDROOM 4
37 ft
0
181 fP
—
1
0
0
ROOF
Roof
Gable Roof
Red
Solar SA Emitt
Emitt Deck
Pitch
# Type Materials Area
Area Color
Barr
Absor. Tested
Tested Insul.
(deg)
1 Hip
Metal 2879 ft'
Oft' Ught
N
0.6 No 0.9
No 0
26.6
ATTIC
/
V
# Type
Ventilation
Vent Ratio (1 in)
Area
RBS - IRCC
1 Full attic
Vented
150
2574 ft-
N N
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
_
1
Under Attic(Vented) MTOILET
30
Blown
40 ft-
0.1
Wood
2
Under Attic (Vented) MBATH
30
Blown
158 ft'
0.1
Wood
3
Under Attic (Vented) MASTER BEDRO 30
Blown
288 ft'
0.1
Wood
_
4
Under Attic (Vented) M W IC
30
Blown
132 ft'
0.1
Wood
_
5
Under Attic (Vented) HALL
30
Blown
48 ft'
0.1
Wood
_
6
Under Attic (Vented) KITCHEN
30
Blown
234 ft'
0.1
Wood
7
Under Attic (Vented) PANTRY
30
Blown
84 ft'
0.1
-
Wood
_
8
Under Attic (Vented) NOOK
30
Blown
110 ft'
0.1
Wood
9
Under Attic (Vented) DINING ROOM
30
Blown
154 ft'
0.1
Wood
_
10
Under Attic (Vented) LAUNDRY
30
Blown
111 ft'
0.1
Wood
11
Under Attic (Vented) FOYER
30
Blown
72 ft'
0.1
Wood
12
Under Attic (Vented) FAMILY ROOM
30
Blown
376 ft'
0.1
Wood
13
Under Attic (Vented) CLST2
30
Blown
14 ft'
0.1
Wood
14
Under Attic (Vented) BEDROOM 2
30
Blown
151 ft'
0.1
Wood
15
Under Attic (Vented) BEDROOM3
30
Blown
165 ft'
0.1
Wood
16
Under Attic (Vented) HALLWAY
30
Blown
40 ft=
0.1
Wood
17
Under Attic(Vented) WIC
30
Blown
48 ft'
0.1
Wood
18
Under Attic (Vented) BATH 2
30
Blown
36 ft'
0.1
Wood
19
Under Attic (Vented) SINKS 2
30
Blown
36 ft'
0.1
Wood
2Q
Under Attic (Vented) WIC4
30
Blown
42 ft'
0.1
Wood
21
Under Attic (Vented) BATH 3
30
Blown
54 fF
0.1
Wood
22
Under Attic (Vented) BEDROOM 4
30
Blain
181 ft'
0.1
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Belau
Space
1
N
Exterior Concrete Block -Ext lnsulM TOILET
4.1
5
0 9
4
46.7 ft'
0
0
0.6
0
_ 2
W
Exterior Concrete Block- Ext InsulM TOILET
4.1
8
0 9
4
74.7 ft'
0
0
0.6
0
3
N
Exterior Concrete Block- Ext Insul M BATH
4.1
6
0 9
4
56.0 ft'
0
0
0.6
0
_ 4
W
Exterior Concrete Block - Ext Insul M BATH
4.1
10
0 9
4
93.3 fN
0
0
0.6
0
_ 5
N
Exterior Concrete Block- Fed Ins&lASTER BE
4.1
16
0 10
4
165.3 ft'
0
0
0.6
0
-6
E
Exterior Concrete Block - Ext InsdNASTER BE
4.1
8
0 10
4
82.7 ft-
0
0
0.6
0
7
W
Exterior Concrete Block- Ext Insul M W IC
4.1
12
0 9
4
112.0 ft'
0
0
0.6
0
_
_ 8
S
Exterior Concrete Block- Ext Insul M W IC
4.1
11
0 9
4
102.7 ft'
0
0
0.6
0
_ 9
S
Exterior Concrete Block- Ext Insul HALL
4.1
4
0 9
4
37.3 ft-
0
0
0.6
0
10
`-11
W
Exterior Concrete Block- Ext Insul HALL
4.1
3
0 9
4
28.0 fP
0
0
0.6
0
W
Exterior Concrete Block - Ext Insul KITCHEN
4.1
6
0 14
0
84.0 it-
0
0
0.6
0
_ 12
S
Exterior Concrete Block - Ext Insul PANTRY
4.1
6
0 9
4
56.0 ft'
0
0
0.6
0
13
W
Exterior Concrete Block -Ext Insul PANTRY
4.1
14
0 9
4
130.7 ft-
0
0
0.6
0
_ 14
N
Exterior Concrete Block- Ext Insul NOOK
4.1
11
0 14
0
154.0112
0
0
0.6
0
_ 15
E
Exterior Concrete Block- Ext Insul NOOK
4.1
7
0 14
0
98.0 ft-
0
0
0.6
0
_ 16
E
Exterior Concrete Block- Ext InsOINING ROO
4.1
5
0 14
0
70.0 ft'
0
0
0.6
0
_ 17
S
Exterior Concrete Block- Ext InsOINING ROO
4.1
11
0 14
0
154.0 iN
0
0
0.6
0
18
S
Exterior Concrete Block- Ext InsuILAUNDRY
4.1
10
0 9
4
93.3 ft-
0
0
0.6
0
11118/201912:04 PM EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
Space
19
E
Exterior
Concrete Block-Ext InsulLAUNDRY
4.1
3
0
9
4
28.Oft-
0
0.6
0
20
-21
S
Exterior
Concrete Block- Ext Insul FOYER
4.1
8
0
14
0
112.0 ft'
0
0
0.6
0
N
Exterior
Concrete Block- Ext Ins81AMILY ROO
4.1
19
0
14
0
266.0 ft'
0
0
0.6
0
_ 22
S
Exterior
Concrete Block - Ext Insd3EDROOM 2
4.1
11
0
9
4
102.7 ft'
0
0
0.6
0
23
W
Exterior
Concrete Block- Ext InstEEDROOM 2
4.1
5
0
9
4
46.7 ft'
0
0
0.6
0
24
E
Exterior
Concrete Block- Ext lnsdBEDROOM3
4.1
15
0
9
4
140.0 ft'
0
0
0.6
0
25
S
Exterior
Concrete Block -Ext lnsd3EDROOM3
4.1
11
0
9
4
102.7 ft'
0
0
0.6
0
26
E
Exterior
Concrete Block- Ext Insul WIC 3
4.1
10
0
9
4
93.3 ft'
0
0
0.6
0
_ 27
E
Exterior
Concrete Block - Ext Insul BATH 3
4.1
6
0
9
4
56.0 ft'
0
0
0.6
0
_ 28
N
Exterior
Concrete Block - Ext InsZEDR00M 4
4.1
15
0
9
4
140.0 ft-
0
0
0.6
0
_ 29
E
Exterior
Concrete Block - Ext InsiMEDROOM 4
4.1
13
0
9
4
121.3 ft'
0
0
0.6
0
30
W
Exterior
Concrete Block- Ext InstSEDROOM 4
4.1
9
0
9
4
84.0 ft'
0
0
0.6
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated HALL
None
.2
2
8
6 8
17.8 ft'
WINDOWS
Orientation shown
is the entered, Proposed
orientation.
Wall
Overhang
V
#
Omt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
_
1
N 3
Metal Low-E Single Yes
0.65
0.25
Y
6.0 ft'
1 ft 6 in
1 ft 4 in
None
None
_
2
W 4
Metal Low-E Single Yes
0.65
0.25
Y
6.0 ft-
1 It 6 in
1 ft4 in
None
None
_
3
N 5
Metal Low-E Single Yes
0.66
0.25
Y
30.0 it-
1 ft 6 in
1 it 4 In
None
None
_
4
E 6
Metal Law-E Single Yes
0.65
0.3
Y
40.0 ft`
1 ft 6 in
1 ft 4In
None
None
_
5
N 14
Metal Low-E Single Yes
0.65
0.25
Y
15.0 ft-
1 ft 6 in
1 ft 4 in
None
None
6
S 17
Metal _ Low-E Single Yes
0.65
0,25
Y
30.0 ft'
1 It 61n
1 ft 4 in
None
None
7
S 20
Metal Low-E Single Yes
0.65
0.3
Y
48.0 ft'
1 ft 6 in
1 ft 4 in
None
None
_
8
N 21
Metal Low-E Single Yes
0.65
0.3
Y
48.0 ft'
1 ft 6 in
1 ft 4 in
None
None
9
S 22
Metal Low-E Single Yes
0.65
0.25
Y
15.0 ft'
1 ft 6 in
1 ft 4 in
None
None
_
10
S 25
Metal Low-E Single Yes
0.65
0.25
Y
15.0 ft'
1 It 6 in
1 it 4 in
None
None
_
11
E 27
Metal Low-E Single Yes
0.65
0.25
Y
6.0 ft'
1 It 6 in
1 ft 4 in
None
None
12
E 29
Metal Low-E Single Yes
0.65
0.25
Y
30.0 ft'
1 It 6 in
1 ft 4 in
None
None
INFILTRATION
#
Scope
Method SLA CFM 50
ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000495 3345.1
183.64
345.37
.196
7
11/18f201912:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Strip Heat/
None
COPA
27 kBtu/hr
1
sys#1
2 Electric Strip Heat/
None
COPA
17 kBtulhr
2
sys#2
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Black
Ducts
1 Central Unit/
Split
Single SEER: 16
35.2 kBtu/hr
1056 cfm
0.8
1
sys#1
2 Central Unit/
Split
Single -SEER: 16
18.8 kBtu/hr
564 cfm
0.8
2
sys#2
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
LAUNDRY 0.98 50 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ft'
DUCTS
—Supply—
—Return
Air
CFM 25 CFM25
HVAC#
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT ON
RLF
Heat Cool
1 Attic 6 150 ft'
Attic
15 ft' Default Leakage
LAUNDRY
(Default) c(Default) c
1 1
2 Attic 6 125 fN
Attic
13 ft' Default Leakage
Attic
(Default) c(Default) c
2 2
TEMPERATURES
Programable(rXT�]hermostat: N
Ceiling Fans:
Feb Mar
Feb Ma
Apr
Apr
JJan �7(�
May n un 1Jul
Many
[X�
1Aug
[X]
]Sep
[ j Oct
L1 Oct
W Nov
Nov
H Dec
Dec
Venting [ ]Ja (
Jun 111 Jul
E
E 1 Aug
E 1 Sep
lxl
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7
8 9
10
11
12
Cooling IWO) AM 78
78 78
78 78 78
78
78 80
80
80
80
PM 80
80 80
80 78- 78
78
78 78
78
78
78
Cooling(WEH) AM 78
78 78
78 78 78
78
78 80
80
80
80
PM 80
80 80
80 78 78
78
78 78
78
78
78
Heating(WD) AM 65
65 65
65 65 65
65
68 68
68
68
68
PM 68
68 68
68 68 68
68
68 68
68
68
68
Heating(WEH) AM 65
65 65
65 65 65
65
68 68
68
68
68
PM 68
68 68
68 68 68
68
68 68
68
68
68
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Defeull(8 lbs/sq.ft.
0 ft'
0 ft
0.3
M TOILET
Default(81bs/sq.ft.
ft'
ft
0.3
M BATH
Default(8 lbs/sq.ft.
ft'
ft
0.3
MASTER BEDROO
Default(8 lbs/sq.f.
ft'
ft
0.3
MWIC
Default(8 lbs/sq.ft.
ft'
ft
0.3
HALL
11/18/2019 12:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
ft'
It
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft'
It
0.3
PANTRY
Default(8 lbs/sq.ft.
ft'
It
0.3
NOOK
Default(8 lbs/sq.ft.
IF
ft
0.3
DINING ROOM
Default(8 lbs/sq.ft.
fF
ft
0.3
LAUNDRY
Default(8 lbs/sq.ft.
fF
ft
0.3
FOYER
Default(8 lbs/sq.ft.
ft'
It
0.3
FAMILY ROOM
Default(8 lbs/sq.ft.
ff`
It
0.3
CLST 2
Default(B lbs/sq.ft.
fF
It
0.3
BEDROOM 2
Default(B lbs/sq.ft.
fF
It
0.3
BEDROOM3
Default(B lbs/sq.ft.
fF
It
0.3
HALLWAY
Default(8 lbs/sq.ft.
fF
It
0.3
WIC
Default(8 lbs/sq.ft.
fF
R
0.3
BATH 2
Default(8 lbs/sq.ft.
fF
ft
0.3
SINKS 2
Default(8 lbs/sq.ft.
if
It
0.3
WIC4
Default(8 lbs/sq.ft.
fF
It
0.3
BATH 3
Default(8 lbs/s.ft.
fF
It
0.3
BEDROOM 4
11/18/2019 12:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 or 7
SCANNED
2017 EPL DISPLAY CARD BY
St. Lucie County
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
�r
The lower the Energy Performance Index,
the more efficient the home.
• 1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
varies
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 4
13. Cooling system: Capacity
54.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/Water source SEERICOP
6. Conditioned floor area (sq. ft.)
6. 2574
d) Room unitIPTAC EER
e) Other
7. Windows, type and area
- a) U-factor:(weighted average)
7a. 0.650
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.274
14. Heating system: Capacity
44.0
c) Area
7c. 289.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.98
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1,
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2. 4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
2. Masonry (Insulation R-value)
1062.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a. 30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I'certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: n G `p 1 Dater'=�J -/ 7 �@yy/
Address of New Home: o OC)0 J pJ 1Q UC-t 6 N'+G'City/FL Zip: FORTFr'0'P `r
11/18/2019 12:05:04 PM EnergyGaugeG USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1