HomeMy WebLinkAboutPLANSDesign Parameters 1. Building Occupancy Category, Paragraph 1604.5 and Table 1604.5: Risk Category 1. 2. Basic Wind Speed, Table 1609C, State of Florida Debris Region S Basic Wind Speed, Paragraph 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed, VuLT=160 MPH 3. Exposure Category, Paragraph 1609.4.3: C Applicable Codes, Regulation and Standards 1. The 6th Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and Specifications for Aluminum Structure, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association, Inc. Washington, D.C., 2010 Edition 3. ASCE7-10 General Notes - - -- 1. The contractor shall verify all dimensions prior to construction 2. A11 work shall comply with all lowland regional ordinances. 3. Any deviation from this plan shall be reviewed by the engineer of record and is subject to approval. Specifications The following specifications are applicable to this projects: 1. Where concrete specification are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable. 1A. Concrete shall conform to ASTM C94 for following components: 1.1.1. Portland Cement Type 1, -ASTM C 150 1.1.2. Aggregate - Large Aggregate 314" max-ASTM C 33 1.1.3. Air entraining +1- 1 % -ASTM C 260 1.1.4. Water reducing agent-ASTM C494 1.1.5. Clean Potable water 1.1.6. Other admixture not permitted 1.2- Metal accessories shall conform to: 1.2.1. Reinforcing Bars - ASTM A615, grade 60 1.2.2. Welded wire fabric-ASTM A185 1.3. Concrete slump at discharge per chute not less then 3" or more than 5". Water added after botching is not permitted. 1.4. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2 and 3 including hatweather rewmmendatiore 1.5. Moist cure or polyethylene curing required. 1.6. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. 1.7. All aluminum components embedded w thin concrete shall be mated with e bituminous paint or epoxy. 1.8. Fiber reinforced concrete per ASTSM Of 116 is an acceptable alternative to 6X6 W1.4/W1.4 WWF. 2. Aluminum extrusions shall be 6005 T5 Alloy. 3. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plate to ASTM B633, or stainless steel series "300". 4. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from end 24" on center or #12 screws 6" from end 12" on center. S. Screened enclosures containing swimming pools shall comply with the applicable requirements of FBC R4501.17 Residential Swimming Barrier requirements. 6. Door location shall be determined by contractor In the field. 7. When installing pavers over concrete slab or footing which are supporting aluminum members, such as contlnuous screen tracks or upright, the anchors must extend past the pavers and reach proper embedment into the underlying foundation. S. All Bashing and waterproofing shall be provided by the contractor. 9. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. 10. Vinyl and acrylic panels shag be removed when wind speeds exceed 75mph Foundation Design: Existing 8"x8" Footing Existing concrete. No additional concrete fooling is required to resist the loads imposes by the proposed construction if the existing footing is in sound condition, free from structural cracking, spaging, or other deterioration. Roof Type Screen Size Hipped Gable 18114 NOLLOw SECTIONS SGl'Kw,�rvG BtAM NGMMI 2.z rxtao.016- FX4sMS zta•.O.eM•[a.tOP 2.66M& Ya5•.0.050•x0.10P gal raa•.o.Osa 2.eeM& r: 6•. 0.a50".o.12R 2.6: r.5•.&Gso- 2X7SM& r.rX0.05rx0.1M OPEN BACK SECTONS 2.e SMB: 2Xa SM& r.Y.oD7r.0.12a' r. P. o.mr.0.121 1.3: 1'. 3'.0.045• MINIMUM FASTENER EDGE DISTANCE: 107 KB: KNEE BRACE SNAP SECTIONS MINIMUM FASTENER SPACING: N4• Rc REGCNANNG 2v26na0.'PVY.0.0aS CONCRETE SCREWANCHOR: SHEEN MATEL SCREWS NSMSI: 3a36roP Y.9'XOASP SIMPSON TNEN HD OR EDUNA3eNT mN-ROEK OR EDUNAIENr NOTE: THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES. DRAWING NOT TO SCALE. USE DIMENSIONS GIVEN. CABLE BRACING MAY TERMINATE AT SLAB IN DIFFERENT LOCATION. MAINTAIN ANGLE PER DETAIL / HOST.', 1X2 (TYP) H- 9 21 3 C- 3 rn 2x3 2X3 2X3 2X3 y 33 rum C- nLL nLL3 na Ria 2X2 S (TYP) 7'-6' RECEIVED aCt 11 1019 Pein`tttLucie cCap Q rtmen St. SCANNED BY St. Lucie Countv ale Copy tS 10- fie REVIEWED F CODE COMP CE ST. LUCIE CO NTY BOCC uauounooaoo 0000 O ®® Oooe IC 00, � 6 �1 0 O O g w Z 4 U. 10 O O 3 O n7 {0 N N F co QU 9 # O p d U. x5d t] M in Ch N a1 O ` LL 9 a d •O OL SHEET 1 1IV BRACKETCUT FROM 1' x 5' ANGLE. CONNECT WITH (9) 914 X We SMS jAL 4-x 590' x t/B' M. FLAT BAR. D G D D G°O EVE RAILO EYEBOLTFOR CABLETENSION O (2) M' DIA. x 3-EMBED - — - — CONCRETE SCREW ALTERNATE CONNECTION ANCHOR UPRIGHT 1V Sa CABLE 1AW x 6-fi16'x UB'ALUM. FLAT DOUBLE BAR. WITH (2) &0' DIA. CONCRETE COMPRESSION SLEEVES ANCHORS. MIN. 2-314' EMBEDMENT ='k� BRICK PAVERS MAY NOT BE PRESENT. ENSURE 2: o MIN, REQUIRED ANCHOR = W EMBEDMENTINTO CONCRETE FOUNDATION PER PLAN '�r E x BR-1 CABLEBRACING 2 SCALE:NTS 2Y3 IIWANGLE EA SIDE O ad e SIDE' (I)WO SCREWAI (1)Irz OIATHRU BOLTWITH NYLOCK JAM NUT(JAM NUT WITH THREADLOCKER MAY BE USED, IN LIEU). DO NOT OVER TIGHTEN, TIGHTEN ONLY UNTIL CONTACT. FOR 2X2 AND 2X3 UPRIGHTS, USE (4) 014 x 3/4'SMS INTO POST BRICK PAVERS. MAY NOT BE PRESENT. ENSURE MINIMUM CONCRETE EMBEDMENT. TOP VIEW AT INTERMEDIATE FOUNDATION PER PLAN UPRIGHT PER PLAN IX20.B. ANCHORED TO CONCRETE WITH IW DO, CONCRETE SCREW ANCHOR 024' D.C. MAX (4) 614 x W4' EMS INTO POST FORCORNERCONNECTION FASTEN lX2 WRH 612 x 3/4- SMS02CO.C. NO X OIX2 UPRIGHT (4)014 x2 SMS THRU IX2 'IMPOST TOPVIEW AT CORNER UPRIGHT TO FOUNDATION CONNECTION SCALE:NTS Note - Orientation may be different. &18'GUSSET PURUNS ATTACHED TO BEAM WTH (4) 010 x 1-1R' SMS WITH WASHE INTO SCREW BOSSES. 614X&4'SMSCI-114-O.C.� A d111111111111� NOTES: 1. SEE THE NOTE BELOW FOR SCREWS SPACING. THE NUMBER OF SCREWB SHOWN ARE FOR ILLUSTRATIVE PURPOSES. GO NOT COUNT SCREWS ON DRAWING. 2. GUSSET DIMENSIONS AREA MINIMUM (2)RED'D-(1) EA SIDE OF BEAM -MAY BE INTERNAL OR EXTERNAL 3. AS BEAM SIZE CHANGES, ADD OR SUBTRACT SCREWS TO MAINTAIN 11WVC SPACING. 4. GUSSET LENGTHS REMAIN CONSTANTLMDTHS CHANGE TO MATCH BEAM SIZE G-1 TYPICAL INTERNAUEXTERAL GUSSET CONNECTION 2 SCALE:NTS vS'x2-x2'ANGUEWTH (4) 4i4 x T4' SMS INTO O O POST 90 RICK PAVERS MY NOT BE PRESENT. FOLLOW I ANCHOR MINIMUM I z� i e eE e �w � A ry SIDE VIEW PER PLAN ANCHOR (MIN. i-1/C EMBED) ® 2e O.C. x We SMSINTO - 4m 1) M' DA CONC. ANCHOR.EMBEDMIN. a e.: FRONT VIEW DOTING SEE PLAN FOR DETAILS DDOORJAMB CONNECTION 20 SCALE:NTS OPTION 1: (4) 610 x 1-1R' SMS INTO SCREW BOSSES (TYP) SELF -MATING BEAM ONLY WOOD; 610 x 3' WOOD SCREWS ®6' FROMFROM ENDS S 12' O.C. CONC. Ile DA x3-CONCRETE SCREW ANCHOR ® WFROM ENDS S 24. O.C. 2' x 2'x IS'ANGLE`MTH (2) 610 x &4' SMS IN EACH FLANGE, EACH SIDE (TYP) I PURUNIGIRTICHAIRRAIL M-1 PURLIN / GIRT / O.B TO HOST CONNECTION 2 SCALE:NTS GUSSET PLATE PER PLAN / DETAILS PURUN PURUN S K OF 0� (Z) i14 X 2' SMS THRU BRACE INTO SEAM TMRU GUSSET PLATE BRACE AT INTERMEDIATE JOINT OF' MAX SAVE RAIL � 1/4' DIA. THRU BOLT WITH NYLON BRACE AT EAVE RAIL WASHERSSTAINIESSSTEELNUT t ROOFBRACING SCALE:NTS O O �6 W) W) N ~ a c66o�6 ++U� •V J G fQ LL O O 9 O = O LL L- 00.3 e O 0 n EL a r W � LL 9 r 4a+ N a` SHEET 2 'fie Copy 0.125 THICK'2• BRACKET® EACH BEAMIPURUN. ATTACHED BRACKETTO FASCIA W/W x3•LAGS jB NOTE: PERBRACI n.ATTACHGUTTER TOFASCIAWITH O WDIAx4'LAGSCREWSFOR 0/S'X 3•LAG ®24' O.C. ELSEWHERE. SPANS GREATER THAN 30'-0' 1• X 2- OPEN BACK IS NOT NEEDED I GUTTER HAS SPLINE GRGOVE OTHERWISE, CONNECT 1X2 TO BEAMJPURUN WITH (2) 910 x 2-1/Y SMS THRU BEAMIPURUN INTD SCREW BOSSES. CONNECT 1X2 TO GUTTER N9TH (1) 314 x 1-1R' SMS ® W FROM 15IDSAND24.O.C. 2°x2•z ANGLE WITH(d CONTRACTOR TO VERIFY FASCIA IS SMSIN 614 xYd•SMS IMO BFAMIPURLIN MINIMUMOF2•x4'.IFLESS,2'Xd° \ND(4)((2) IF I)C?I bCREWED TO PTSUB FASCIA SHALL BE PLACED BEHIND EXISTING AND LAG LAG IEAM USING SCREW BOSSESILI4 UPER GUTTER SCREWSSHALLBELENGTHENED l TV SMS INTO 1X2 (OR GUTTER). TO FULLY PENETRATE SUB FASCIA, REPEAT ON OTHER SIDE OF IF NO FASM IS EXISTING, ADD T z BE URUN 4' PT FASCIA WITH IJ2' DIA. LAG WHEN BEAM IS LARGER THAN GUTTER, .052•BACKING PLATE BOLTS, EMBEDDING I-1/2•INTO 21M'xl VWx 0.Mr(MIN.) ALUM ON INSIDE OF GUTTER TRUSS TAILS. PRE-0RILL WITH3/B• RECEIVING CHANNEL W/ MIN. (2) #12 x DIA BIT TO PREVENTSPLNTNG. 3M' SMS SHIM AS NECESSARY IF OTHER THAN A PLUMB CUT FASCIA NOTE: BEAM ORIENTATION MAY BE DIFFERENT THAN ILLUSTRATED RH-1 BEAWPURLIN TO GUTTER CONNECTION 3 SCALE:NTS MEMBERSIZE EDGE•C• R.`T4 I2 2X5 1' 2%B-2X10 112• FLASHING EAVE RAIL INTERNALLY SCREWTHRUBEAMINTO - - SCREW BOSSES WITH (3) C10 x 1-V2' SMS ATTACH 1X2 TO EAVE RAIL WITH 9/4 x 1-12' SMS @ 6' FROM ENDS S 24. O.C. (1)1W DIA. z 2-117 THRU BOLT WITH NYLOCK JAM NUT. THREADLOCKER MAYBE USED ON NUT IN LIEU OF NYLOCK JAM NUT. DO NOT OVERTIGHTEN. RC-1 UPRIGHT TO BEAM CONNECTION 3 SCALE:NTS NOTCH BOTTOM FLANGE OF PURUN TO OVERLAP UPRIGHT SCREW THRU EAVE RAIL INTO PURUN SCREW BOSSES WITH (2) 010 x 4' SMS ATTACH 1X2 TO EAVE RAIL WITH 4WD x 1-in• SMS ®b• FROM ENDS b 24. O.C. 2• x T'x 11V PLATE WITH (4) 014 xW/ SMSEACHSIDEOFBEAM UPRIGHT PER PLAN C-2 UPRIGHT TO PURLIN CONNECTION 3 SCALE: NTS q�IL IL a obi$ O O� lee,®�ouo ooauu O O r 9 O O 3 0 0 m v U) 0 0 V J 0 A N O 9 d 7 U. = J N M. In 'a �wr W O ` LL 9 9 Q M a d .O V a SHEET 3 opy