Loading...
HomeMy WebLinkAboutENERGY EFFICIENCYSCANNED BY FORM R405-2017 St. Lucie County FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: LUSTER GUEST HOUSE BuilderName: Street: 10750 HFEIL RD. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, PennitNumber: Owner: JOHNNIE & KATHERINE LUSTER Jurisdiction: ST. LUCIE COUNTY DesignLocation: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) -1-New construction or existing New (From Plans) 9. Wall Types(2088.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Int lnsul, Exterior R=4.1 1280.00 ft' b. Frame -Wood, Exterior R=13.0 808.00 ft" 3. Number of units, if multiple family 1 c. N/A R= fi2 4. Number of Bedrooms 0 d.N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2122.0 sgft.) Insulation Area a. UnderAltic(Vented) R=30.0 2122.00ft3 6. Conditioned floor area above grade(ft) 2122 b. N/A p R= ft' Conditionedfloorareabelowgradeift) 0 c. N/A R= fF 11. Ducts R f 2 7. Windows (135.0 sgfL) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 225 a. U-Factor: SgI, U=0.79 120.00 ft' SHGC: SHGC=0.50 b. U-Factor. SgI, U=0.65 15.00 ft- 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 46.5 SEER:16.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor: N/A fill a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 f. Area Weighted Average SHGC: 0.472 14. Hot water systems a. Electric Cap:50 gallons 8. Floor Types (2110.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 2110.00 fill b. Conservation features b. WA R= ft' None c. N/A R= ft' 15. Credits CF, Pstat Total Proposed Modified Loads: 55.43 Glass/Floor Area: 0.064 PASS Total Baseline Loads: 56.68 I hereby certify that the plans and specifications covered by Review of the plans and STgp� this calculation are in compliance with the Florida Energy specifications covered by this OFTNE y Code. calculation indicates compliance °„ with the Florida Energy Code. 1� rrxr .. h. •.sr';..� O PREPARED BY: �1/ Before construction is completed DATE: 2-20-202 this building will be inspected for compliance with Section 553.908 yh aG . c I hereby certify that this ' ing, as designed, is in compliance Florida Statutes. It with the Florida Energy Code. GOp WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). FILE COPY 2/20/202012:08 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Pagel of 6 AT P9 r1\Al1T FORMR405-2017 trvruI IUIYIMAMT LInr-kfr%LQ1 1%GrWM1 PROJECT Title: LUSTER GUEST HOUSE Bedrooms: 0 Address Type: StreetAddress Building Type: User CondilionedArea: 2122 Lot# OwnerName: JOHNNIE & KATHERINE LUS Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: BuilderName: RotateAngle: 0 Street: 10750 HFEIL RD. _ Permit Office: ST-LUCIE COUNTY— — CrossVenblagon:--No— - County: _ St. Lucie _ _ Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, Stale, Zip: FT. PIERCE, FamilyType: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE DesignTemp Int Design Temp Heating Design DailyTemp DesignLocation TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2122 16976 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infi11D Finished Cooled Heated 1 LIVING ROOM 410 3280 No 4 1 Yes Yes Yes 2 WIC 48 384 No 0 1 Yes Yes Yes 3 WIC 2 42 336 No 0 1 Yes Yes Yes 4 BEDROOM 412 3296 No 2 1 Yes Yes Yes 5 LAUNDRY 120 960 No 0 1 Yes Yes Yes 6 KITCHEN 382 3056 No 0 1 Yes Yes Yes 7 BATHROOM 168 1344 No 0 1 Yes Yes Yes 8 TLT. 28 224 No 0 1 Yes Yes Yes 9 2nd Floor 512 4096 No 0 0 1 Yes Yes Yes FLOORS # FloorType Space Perimeter Perimeted2-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation LIVING ROOM 40 ft 0 400 ft2 _--- 0 1 0 2 Slab -On -Grade Edge Insulation WIC 8ft 0 48 ft2 _-__ 0 1 0 3 Slab -On -Grade Edge Insulation WIC 2 13 It 0 42 ft2 ---_ 0 1 0 4 Slab -On -Grade Edge Insulation BEDROOM 24.9ft 0 410 ft' ---- 0 1 0 5 Slab-On-GradeEdge Insulation LAUNDRY 26ft 0 120 ft' _--- 0 1 0 6 Slab -On -Grade Edge Insulation KITCHEN 20ft 0 382 ft2 _--- 0 1 0 7 Slab -On -Grade Edge Insulation BATHROOM 17ft 0 168ft' ---_ 0 1 0 2/20/2020 12:08 PM EnergyGauge® USA 6.0.02 (Rev. 1) -FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulation TLT. lift 0 28 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulation 2nd Floor 102it 0 512 ft2 ---- 0 0 1 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 7 Hip Compositionshingles 2299IF Oft' Light N 0.6 No 0.7 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2122 ft2 N N CEILING # CeilingType Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAttic(Vented) LIVING ROOM 30 Blown 410 ft2 0.1 Wood 2 UnderAltic(Vented) WIC 30 Blown 48 112 0.1 Wood 3 UnderAttic(Vented) WIC 2 30 Blown 42 ft2 0.1 Wood _ 4 UnderAttic(Vented) BEDROOM 30 Blown 412 ft2 0.1 Wood 5 UnderAttic(Vented) LAUNDRY 30 Blown 120 ft2 0.1 Wood 6 UnderAttic(Vented) KITCHEN 30 Blown 382 ft2 0.1 Wood 7 UnderAttic(Vented) BATHROOM 30 Blown 168 ft2 0.1 Wood _ 8 UnderAttic(Vented) TLT. 30 Blown 28 ft2 0.1 Wood 9 UnderAtOc(Vented) 2nd Floor 30 Blown 512 112 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w _1 SE Exterior Concrete Block- Int lnsuLIVING ROO 4.1 20 0 8 0 160.0 ft2 0 0 0.3 0. _2 SW Exterior Concrete Block- Int lnsuLIVING ROO 4.1 20 0 8 0 160.0 ft2 0 0 0.3 0 3 SW Exterior Concrete Block - Intlnsul WIC 4.1 8 0 8 0 64.0 112 0 0 0.3 0 _4 SW Exterior Concrete Block- Intlnsul WIC2 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 _5 NW Exterior Concrete Block-Intlnsul WIC2 4.1 6 0 8 0 48.0 ft2 0 0 0.3 0 6 SW Exterior Concrete Block- Int lnsul BEDROOM 4.1 5 0 8 0 40.0 ft2 0 0 0.3 0 _7 NW Exterior Concrete Block- Int lnsul BEDROOM 4.1 20 0 8 0 160.0 112 0 0 0.3 0 _8 NE Exterior Concrete Block- Int lnsul LAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.3 0 _9 SE Exterior Concrete Block- Int lnsul LAUNDRY 4.1 20 0 8 0 160.0 112 0 0 0.3 0 _10 NE Exterior Concrete Block-Intlnsul KITCHEN 4.1 20 0 8 0 160.0 ft2 0 0 0.3 0 _11 NE Exterior Concrete Block- Int lnsuBATHROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.3 0 _12 NW Exterior Concrete Block- Int lnsuBATHROOM 4.1 7 0 8 0 56.0 112 0 0 0.3 0 _13 NE Exterior Concrete Block - Intlnsul TLT. 4.1 4 0 8 0 32.0 112 0 0 0.3 0 _14 NW Exterior Concrete Block - Intlnsul TLT. 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 _16 N Exterior Frame -Wood 2nd Floor 13 38 8 304.0 ft2 0.23 0.3 0 2/20/202012:08 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3of5 � ., ' Idol IT SI IMMARY CFIFCKI IST REPORT runivi WALLS Adjacent Cavity Width HeighPValue Sheathing Framing Solar Below 0 Space Ft In _Ft I�tArea 16 E Exterior Frame -Wood 2nd Floor 13 12 6 8 100.0ft 0.23 0.3 0 17 S Exterior Frame -Wood 2nd Floor 13 38 8 304.0 ft2 0.25 0.3 0 18 --W - Exterior _Frame=Wood_ _ 2nd Floor 13 12 6 8 100.0 ft2 0.25 0.3 0 DOORS # Omt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 SW Insulated LIVING ROO None .32 3 6 8 20ft2 _ 2 W Insulated 2nd Floor None .46 3 6 8 20ft2 WINDOWS Orientation shown isthe entered, Pro osed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 SW 2 Metal Single(Clear) Yes 0.79 0.5 N 20.0W 2ft0in 1ft4in None None _ 2 SW 6 Metal Single(Clear) Yes 0.79 0.5 N 20.0 ft- 2ft0in 1ft4 in None None _ 3 NW 7 Metal Single(Clear) Yes 0.79 0.5 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 4 NE 10 Metal Single(Clear) Yes 0.79 0.5 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None _ 5 NE 11 Metal Single(Clear) Yes -0.79 0.5 N 20.0 ft' 2 It 0 in 1 ft 4 in None None 6 NW 12 Metal Single(Clear) Yes 0.79 0.5 N 20.0 ft2 2It0 in 1ft4 in None None 7 W 18 Metal Low-ESingle Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft4 in Drapesfblinds Exleriorl INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000254 1414.7 77.66 146.06 .0881 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 CentralUnit/ Split Single SEER: 16 46.5 kBtulhr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SelPnt Conservation 1 Electric None Attic 0.95 50gal 60.9 gal 120deg None 2/20/2020 12:08 PM EnergyGauge® USA 6.0.02 (Rev. 1) -FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # CompanyName System Model# CollectorModel# Area Volume FEF None None ft' DUCTS / —Supply— —Return— Air CFM25 CFM25 HVAC# V # Location R-Value Area Location Area LeakageType Handler TOT OUT QN RLF Heal Cool 1 Attic 6 225 ft' Attic 55 ft' DefaultLeakage Attic (Default) c(Default) c TEMPERATURES ProgramablreT,Jhermostatrr:''Y Ceiling Fans: Healing Jan [X] FDec eb jj [X] Mar M Apr Me �X�Sep r Oct Novr()(')Dec[rX,] Nov Venting [ ]Jan [I I) Feb l l Mar May Jun [ Jul Aug [X] Nov [ ] D ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Ccoling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness FumitureFraction Space Default(8lbs/sq.ft. 0 ft2 0 ft 0.3 LIVING ROOM Default(8lbs/sq.ft. ft' ft 0.3 WIC Default(Blbs/sq.ft. ft' ft 0.3 WIC Default(8lbs/sq.fL ft' ft 0.3 BEDROOM Default(8 lbs/sq.fL ft' ft 0.3 LAUNDRY Default(Blbs/sq.ft. ft' ft 0.3 KITCHEN Default(8lbs/sq.ft. ft' ft 0.3 BATHROOM Default(8lbs/sq.fL ft' ft 0.3 TLT. Default 8lbs/s .ft. 0 ft' Oft 0.3 2nd Floor 2/20/202012:08 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FSC 6lh Edition(2017) Compliant Software Page 5of5