Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEr RECEIVED SCANNED BY OCT 14 2019 St. Lucie County FORM R405-2017 ST. Lucie County, Permitting FLORIDA ENERGY EFFICIENCY CODE F NSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WALSH RESIDNECE Builder Name: DAVE GOLDEN HOMES, INC. Street: JOHNSTON ROAD „ Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or ewsting New (From Plans) 9. Wall Types (2557.3 sqft.) Insulation Area 2062.70 ft' a. Concrete Block - E)d Insul, EMerior R=4.1 2. Single family or multiple family Single-family y b. Frame - Wood, Adjacent R=11.0 494.67 ft' 3. Number of units, if multiple family 1 c. N/A R= ft 3 d. N/A R= ft, 4. Number of Bedrooms 10. Ceiling Types (3065.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 3065.00 ft' 6. Conditioned floor area above grade (ft2) 3065 A R ft R= ft2 c. N/A Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(452.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 200 a. U-Factor. Sgl, U=0.65 232.80 ft2 SHGC: SHGC=0.25 12. Cooling systems kBtu/hr Efficiency b. U-Factor: Sgl, U=0.65 220.00 ft' a. Central Unit 46.5 SEER:16.00 SHGC: SHGC=0.30 c. U-Factor. N/A SHGC: ft2 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.333 ft. 14. Hot water systems Area Weighted Average SHGC: - 0.274 a. Electric Cap: 50 gallons 8. Floor Types (3065.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 3066.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Total Proposed Modified Loads: 89.54 PASS Glass/Floor Area: 0.148 Total Baseline Loads: 91.57 I hereby certify that the plans and specifications covered by Review of the plans and �Q ftt8Tgrd' this Calculation are in compliance with the Florida Energy specifications covered by this indicates compliance Code. calculation with the Florida Energy Code. PREP E Y: P O-*T Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 _ t a a I hereby certify that this buildin , desi ned, i in compliance Florida Statutes. with the Florida Energy Code®�� OWNER/AGENT, BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 0 g 201% NOV 9/20/2019 11:12 AM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant rele 60 page 1 of 7 urns IV Of InnM A0V P`YGCL[I IRT RP12r1RT - PROJECT Title: WALSH RESIDNECE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 3065 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: DAVE GOLDEN HOMES, INC Rotate Angle: 0 Street: JOHNSTON ROAD Permit Office: ST LUCIE COUNTY Cross Ventilation: No County. St Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/E)dsting: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp J Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 3065 28504.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 LAUNDRY 126 1171.8 No 0 1 Yes Yes Yes 2 HALLWAY 45 419 No 0 1 Yes Yes Yes 3 KITCHEN 236 2194.8 Yes 0 1 Yes Yes Yes 4 SUN ROOM 161 1497.3 No 0 1 Yes Yes Yes 5 GREAT ROOM 610 5673 No 0 1 Yes Yes Yes 6 LINEN 16 148.8 No 0 1 No Yes Yes 7 PANTRY 24 223.2 No 0 1 No Yes Yes 8 FOYER 189 1757.7 No 0 1 Yes Yes Yes 9 BATH 3 60 558 No 0 1 No Yes Yes 10 OFFICECLST 25 232.5 No 0 1 No Yes Yes 11 OFFICE 220 2046 No 0 1 Yes Yes Yes 12 WIC 44 409.2 No 0 1 No Yes Yes 13 BEDROOM 2 211 1962.3 No 0 1 1 Yes Yes Yes 14 BEDROOMS LIVIN 154 1432.2 No 0 1 No Yes Yes 15 M WIC 90 837 No 0 1 No Yes Yes 16 HALL 36 334.8 No 0 1 No Yes Yes 17 MASTER BEDROO 283 2631.9 No 0 1 1 Yes Yes Yes 18 M HALL 16 148.8 No 0 1 No Yes Yes 19 M BATH 156 1450.8 No 0 1 Yes Yes Yes 20 M TOILET 20 186 No 0 1 No Yes Yes 21 BATH 2 88 818.4 No 0 1 Yes Yes Yes 22 WIC 44 409.2 No 0 1 Yes Yes Yes 9/20/2019 11:12 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 shim it CI IRARAA12V f-WFf K1 ICT REPORT r V ruVl K4Uz)-tu 11 uv . v....... r- SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 23 BEDROOM 3 211 1962.3 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation LAUNDRY 23 ft 0 126 fN — 1 0 0 2 Slab -On -Grade Edge Insulation HALLWAY 5 ft 0 45 ft' -_ 1 0 0 3 Slab -On -Grade Edge Insulation KITCHEN 12 It 0 236 ft2 -- 1 0 0 4 Slab -On -Grade Edge Insulation SUN ROOM 36 It 0 161 ft2 -- 1 0 0 5 Slab -On -Grade Edge Insulation GREAT ROOM 13 It 0 610 ft2 _- 1 0 0 6 Slab -On -Grade Edge Insulation LINEN t ft 0 16 ft2 -_ 1 0 0 7 Slab -On -Grade Edge Insulation PANTRY t ft 0 24 ft' _- 1 0 0 8 Slab -On -Grade Edge Insulation FOYER 7ft 0 189 ft2 -_ 1 0 0 9 Slab -On -Grade Edge Insulation BATH 3 1 ft 0 60 ft' _- 1 0 0 10SIab-On-Grade Edge Insulation OFFICE CLST 'I ft 0 - 25 ft' _-- 1 0 0 11SIab-On-Grade Edge Insulation OFFICE 7ft 0 220 ft2 -- 1 0 0 12SIab-On-Grade Edge Insulation WIC 2 1 ft 0 44 ft2 — 1 0 0 13SIab-On-Grade Edge Insulation BEDROOM 2 28 ft 0 211 ft2 — 1 0 0 14SIab-On-Grade Edge Insulation BEDROOMS LIVI 1 ft 0 154 ft2 -- 1 0 0 15Slab-On-Grade Edge Insulation M WIC t ft 0 90 ft2 -- 1 0 0 16SIab-On-Grade Edge Insulation HALL t ft 0 36 ft2 -- 1 0 0 17SIab-On-Grade Edge Insulation MASTER BEDRO 34 ft 0 283 112 -- 1 0 0 18SIab-On-Grade Edge Insulation M HALL t ft 0 16 ft' -- 1 0 0 19SIab-On-Grade Edge Insulation M BATH 16 ft 0 156 ft2 -- 1 0 0 20SIab-On-Grade Edge Insulation M TOILET 1 ft 0 20 ft" 1 0 0 21SIab-On-Grade Edge Insulation BATH 2 8 ft 0 88 ft2 -_ 1 0 0 22SIab-On-Grade Edge Insulation WIC 3 4 ft 0 44 ft' _- 1 0 0 23SIab-On-Grade Edge Insulation BEDROOM 3 28 It 0 211 ft2 _- 1 0 0 9/20/2019 11:12 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Bart Absor. Tested Tested Insul. (deg) 1 Hip Metal 3428 ft2 0 ft2 Light N 0.2 No 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 3065 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) LAUNDRY 0 Bloom 126 1`12 0.1 Wood _ 2 Under Attic(Unvented) HALLWAY 0 Blown 45 ft2 0.1 Wood _ 3 Under Attic (Unvented) KITCHEN 0 Blown -236 ft2 0.1 Wood _ 4 Under Attic (Unvented) SUN ROOM 0 Blown 161 ft2 0.1 Wood _ 5 Under Attic (Unvented) GREAT ROOM 0 Blown 610 ft2 0.1 Wood _ 6 Under Attic (Unvented) LINEN 0 Blown 16 ft2 0.1 Wood _ 7 Under Attic(Unvenled) PANTRY 0 Blown 24 fN 0.1 Wood _ 8 Under Attic (Unwrited) FOYER 0 Blown 189 ft2 0.1 Wood _ 9 Under Attic (Unvented) BATH 3 0 Blown 60 fP 0.1 Wood _ 10 Under Alto (Unvented) OFFICE CLST 0 Blown 25 ft 0.1 Wood _ 11 Under Alto(Unvented) OFFICE 0 Blown 220 ft2 0.1 Wood _ 12 Under Attic(Unvented) WIC 0 Blown 44 ft2 0.1 Wood _ 13 Under Attic(Unvented) BEDROOM 0 Blown 211 ft2 0.1 Wood _ 14 Under Attic (Unvented) BEDROOMS LIVI 0 Blown 154 ft2 0.1 Wood _ 15 Under Attic (Unvented) M WIC 0 Blown 90 N2 0.1 Wood _ 16 Under Attic(Unvented) HALL 0 Blown 36 ft2 0.1 Wood _ 17 Under Attic (Unvented) MASTER BEDRO 0 Blown 283 ft2 0.1 Wood _ 18 Under Attic (Unvented) M HALL 0 Blown 16 ft2 0.1 Wood _ 19 Under Attic (Unvented) M BATH 0 Blown 166 ft2 0.1 Wood _ 20 Under AtOc(Unvented) MTOILET 0 Blown 20 ft2 0.1 Wood _ 21 Under Attic (Unvented) BATH 2 0 Blown 88 ft2 0.1 Wood _ 22 Under Attic (Unvented) WIC 3 0 Bloom 44 ft2 0.1 Wood _ 23 Under Attic(Unvented) BEDROOM 0 Blown 211 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 S Exerior Concrete Block- EM InsuILAUNDRY 4.1 14 0 9 4 130.7 ft2 0 0 0.2 0 _ 2 W Exterior Concrete Block- Ext InsullAUNDRY 4.1 9 0 9 4 84.0 ft2 0 0 0.2 0 3 S Exterior Concrete Block- Ext Insu1HALLWAY 4.1 5 0 9 4 46.7 112 0 0 0.2 0 4 E Garage Frame -Wood HALLWAY 11 7 0 9 4 65.3 ft2 0 0.1 0.2 0 5 W Exterior Concrete Block- Ext Insul KITCHEN 4.1 12 0 9 4 112.0 ft2 0 0 0.2 0 _ 6 E Garage Frame - Wood KITCHEN 11 4 0 9 4 37.3 ft2 0 0.1 0.2 0 920/201911:12 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 INPUT SUMMARY CHECKLIST REPORT t-uRM R405-2011 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below 0 Space 7 N Exterior Concrete Block - Ext InsuSUN ROOM 4.1 10 0 9 4 93.3 ft' 0 0 0.2 0 _ 8 S Exterior Concrete Block - Ext InsuSUN ROOM 4.1 10 0 9 4 93.3 ft' 0 0 0.2 0 _ 9 W Exterior Concrete Block- Ext Insu6UN ROOM 4.1 16 0 9 4 149.3 ft2 0 0 0.2 0 _ 10 W Exterior Concrete Block- Fxd Inst3REAT ROO 4.1 13 0 9 4 121.3 ft2 0 0 0.2 0 _ 11 E Garage Frame -Wood LINEN 11 4 0 9 4 37.3 ft2 0 0.1 0.2 0 12 S Garage Frame -Wood LINEN 11 4 0 9 4 37.3 ft2 0 0.1 0.2 0 13 E Garage Frame - Wood PANTRY 11 6 0 9 4 56.0 ft2 0 0.1 0.2 0 _ 14 N Garage Frame -Woad PANTRY 11 2 0 9 4 18.7 ft2 0 0.1 0.2 0 15 E Exterior Concrete Block - Ext Insul FOYER 4.1 7 0 9 4 65.3 ft2 0 0 0.2 0 _ 16 S Garage Frame - Wood FOYER 11 26 0 9 4 242.7 ft2 0 0.1 0.2 0 17 E Exterior Concrete Block - Ext Insul OFFICE 4.1 7 0 9 4 65.3 ft' 0 0 0.2 0 _ 18 E Exterior Concrete Block - Ext Inst8EDROOM 2 4.1 15 0 9 4 140.0 ft2 0 0 0.2 0 _ 19 S Exterior Concrete Block - Ext Ins51EDROOM 2 4.1 13 0 9 4 121.3 ft2 0 0 0.2 0 _ 20 N Exterior Concrete Block - Ext InstIRASTER BE 4.1 19 0 9 4 177.3 ft2 0 0 0.2 0 21 W Exterior Concrete Block- Ext InsWASTER BE 4.1 15 0 9 4 140.0 ft' 0 0 0.2 0 _ 22 N Exterior Concrete Block - Ext Insul M BATH 4.1 16 0 9 4 149.3 ft' 0 0 0.2 0 _ 23 N Exterior Concrete Block- Ext Insul BATH 2 4.1 8 0 9 4 74.7 ft' 0 0 0.2 0 _ 24 N Exterior Concrete Block- Ext Insul WIC 3 4.1 4 0 9 4 37.3 ft2 0 0 0.2 0 _ 25 N Exterior Concrete Block - Ext InstSEDROOM 3 4.1 13 0 9 4 121.3 fP 0 0 0.2 0 _ 26 E Exterior Concrete Block - Ext InstSEDROOM 3 4.1 15 0 9 4 140.0 ft' 0 0 0.2 0 DOORS # Omt Door Type Space Storms U-Value Width Height In Area Ft In Ft 1 S Insulated HALLWAY None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang v # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 2 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft- 1 ft4 in 1 ft 4 in Drapes/blinds Exterior 5 _ 2 W 5 Metal Low-E Single Yes 0.65 0.25 N 18.0 ftt ft 4 in 1 It 4 in None None _ 3 N 7 Metal Low-E Single Yes 0.65 0.3 N 40.0 ft2 1 ft 4 in 1 ft4 in Drapes/blinds Exterior 5 _ 4 S 8 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft2 1 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 _ 5 W 9 Metal Law-E Single Yes 0.65 0.25 N 54.0 ft' 1 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 _ 6 W 10 Metal Low-E Single Yes 0.65 0.3 N 96.0 ft2 1 ft 4 in 1 ft 4 in None None _ 7 E 15 Metal Low-E Single Yes 0.65 0.3 N 36.0 ft' 1 ft 4 in 1 ft 4 in None None _ 8 E 17 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft' 1 ft 4 in 1 ft 4 in None None _ 9 E 18 Metal Low-E Single Yes 0.65 0.25 N 36.0 ft- ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 _ 10 N 20 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft' 1 ft 4 in 1 ft 4 in None None _ 11 W 21 Metal Low-E Single Yes 0.65 0.3 N 48.0 ft' ft 4 in 1 It 4 in None None _ 12 N 22 Metal Low-E Single Yes 0.65 0.25 N 7.8 k2 1 If 4 in 1 ft 4 in None None _ 13 N 23 Metal Low-E Single Yes 0.65 0.25 N 9.0 1? 1 It 4 in 1 ft 4 in None None _ 14 E 26 Metal Low-E Single Yes 0.65 0.25 N 36.0 ft' 1 ft4 in 1 ft 4 in Drapes/blinds Exterior 5 91201201911:12 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 INPUT SUMMARY CHECKLIST REPORT I-uRM R405-20 it GARAGE # Floor Area Ceiling Area E=osed Wall Perimeter Avg. Wall Height ENrosed Wall Insulation 1 704 ft 704 ft' 54 ft 9 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000414 3325.6 182.67 343.35 .1522 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 34 kBlu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 46.5 kBtu/hr 1395 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SelPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Can # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS # — Supply-- Location R-Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 200 ft' Attic 20 ft' Prop. Leak Free Garage — cfm 91.9 cfm 0.03 0.50 1 1 9120/201911:12 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 u�ru rT c.� ree RRAov ru C/`I[I I¢T 01=13l1RT FORM R4Ub-ZU1 / — — TEMPERATURES Programabler[XT']hermostat[::Jan N C[[eilliing Fans:Cooling [Feb�X]] Marr May[[X]] Jul[D(]I f[ rl Aug 4 ]] Sep Sep �[X]]Nov f[Xj]Dee Dec Dec Vent ng [ ] Jan [ ] Feb [X] Mar Apr [ ] May [ ] Jun [ ] J [x] Oct [X] Nov [ ] Thermostat Schedule: HERS 2006 Reference Hours 12 Schedule Type 1 2 3 4 5 6 7 8 9 10 11 Cooling (VJD) PM 80 80 80 78 78 78 78 78 78 78 78 80 Cooling (WEH) PM 80 80 80 78 78 78 78 78 78 78 78 80 Heating (WD) PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 688 8 68 6 8 MASS Mass Type Area Thickness Fumiture Fraction Space Defauft(8 lbs/sq.ft. Oft2 0 ft 0.3 LAUNDRY Default(8 lbs/sq.ft. 112 ft 0.3 HALLWAY Defauk(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft' ft 0.3 SUN ROOM Default(8 lbs/sq.ft. ft2 ft 0.3 GREAT ROOM Default(8 lbs/sq.ft. ft' ft 0.3 LINEN Default(8 lbs/sq.ft. ft' ft 0.3 PANTRY Default(8 lbs/sq.ft. ft' ft 0.3 FOYER Default(8 lbs/sq.ft. ft' ft 0.3 BATH 3 Default(81bs/sq.ft. ft2 ft 0.3 OFFICE CLST Default(8 lbs/sq.ft. ft' ft 0.3 OFFICE Default(81bs/sq.ft. ft' ft 0.3 WIC Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM2 Default(8 lbs/sq.ft. ft' ft 0.3 BEDROOMS LIVIN Default(81bs/sq.ft. ft' ft 0.3 MWIC Default(81bs/sq.ft. ft' ft 0.3 HALL Default(8 lbs/sq.ft. ft, ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft' ft 0.3 M HALL Default(81bs/sq.ft. ft' ft 0.3 M BATH Default(8 lbs/sq.ft. ft' ft 0.3 MTOILET Default(8 lbs/sq.ft. ft' ft 0.3 BATH 2 Default(8 lbs/sq.ft. ft2 ft 0.3 WIG Default 8lhs/s .ft. ft' ft 0.3 BEDROOM 3 9/20/2019 11:12 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WALSH RESIDNECE Builder Name: DAVE GOLDEN HOMES, INC. Street: JOHNSTON ROAD Permit Office: ST LUCIE COUNTY Y City, State, Zip: FORT PIERCE, FL, Permit Number: rU Owner: Jurisdiction: ST LUCIE COUNTY = Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks orjoints in the air barrier shall be sealed. The air barrier in any dropped ceiling/saffil shall be aligned with the The insulation In any dropped ceiling/soffit Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls Walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to maintain permanent contact with the underside of (including subfloor decking, or floor framing cavity insulation shall above -garage and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the lop of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation be attached to the crawlspace walls. Class I vapor retarder with overlapping joints taped. shall permanently Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation Narrow cavities readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. - Batt insulation shall be cut neatly to fit around wiring a Plumbing and wiring plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Piping an wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection or log walls snan oe in accomancewim mu pruwsiuns vl =-vvv. 9120/2019 11:12 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 - - - - -2017- EPL-DISPLAY--CARD -- - - - ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level 6.0 a) Supply. ducts. R 2. Single-family or multiple -family 2. Single-family s R Garage c) AHUrnlocation 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity SEER 46.5 16.0 a) Split system 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned Floor area (sq. ft.) 6. 3065 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.274 c) Area 7c. 452.8 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 10131. 11.0 10B2. 11a. 0.0 11 b. 11 c. 11d. No 14. Heating system: Capacity 34.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.98 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ 0 Heat recovery unit HeatRec%/ g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans b) Cross ventilation No c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be in ed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completeQVboed on installed de compliant features. Builder Signature: Date: Address of New Home: JOHNSTON ROAD City/FL Zip: FORT PIERCE. FL 9120/2019 11:12:52 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1