RE: J38351 - Walsh Residence MiTek USA, Inc.
Site Information` 6904 Parke East Blvd.
Customer Info: Dave Golden Homes Project Name: Walsh Residence Model: Custori1FL33610-4115
Lot/Block: Subdivision:
Address: XXX Johnston Road
City: Ft. Pierce State: Florida
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License #:
Address:
City: State:
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TPI2014 Design Program: MiTek 20/20 8.2
Wind Code: ASCE 7-10 [All Heigh1l Wind Speed: 160 mph
Roof Load: 50.0 psf Floor Load: N/A psf
This package includes 75 individual, Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No. Seal# Truss Name Date No. Seal#
1
T18074324
A01
9/10/19
23
T18074346
2
T18074325
A01A
9/10/19
24
T18074347
3
T18074326
A02
9110/19
25
T18074348
4
T18074327
A03
9/10/19
26
T18074349
5
T18074328
A03A
9/10/19
27
T18074350
6
T18074329
A04
9/10/19
28
T18074351
7
T18074330
A05
9/10/19
29
T18074352
8
T18074331
A06
9/10/19
30
T18074353
9
T18074332
A07
9/10/19
31
T18074354
10
T18074333
A08
9/10/19
32
T18074355
11
T18074334
A09
9/10/19
33
T18074356
12
T18074335
A09G
9/10/19
34
T18074357
13
T18074336
A10
9/10/19
35
T18074358
14
T18074337
All
9/10/19
36
T18074359
15
T18074338
Al2
9/10/19
37
T18074360
16
T18074339
A13
9/10/19
38
T18074361
17
T18074340
A14
9/10/19
39
T18074362
18
T18074341
A15
9/10/19
40
T18074363
19
T18074342
A16
9/10/19
41
T18074364
20:
T18074343
A17
9/10/19
42
T18074365
21
T18074344
AtBG
9/10/19
43
T18074366
22
T18074345
B01G
9/10/19
44
T18074367
Truss Name Date
B02 9/10/1
The truss drawing(s) referenced above have been prepared by
MiTek USA, Inc. under my direct supervision based on the parameters
provided by East Coast Truss.
Truss Design Engineer's Name: Albani, Thomas
My license renewal date for the state of Florida is February 28, 2021.
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdiction(s) identified and that the
designs comply with ANSI/rPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek or TRENCO. Any project specific information included is for MiTek's or
TRENCO's customers file reference purpose only, and was not taken into account in the
preparation of these designs. MiTek or TRENCO has not independently verified the
applicability of the design parameters or the designs for any particular building. Before use,
the building designer should verify applicability of design parameters and properly
incorporate these designs into the overall building design perANSI/rPI 1, Chapter 2.
\r•/ Wr0•••'ti
33. ATE OF rQJ
� EN�•�
CNANOv .®6 ZQ�9
Thomas AAl ant PE No.39380 �'/'►���
6904 Iarks (East Blvd. Tampa R 3391U �g
Data
September 10,2019
Albani, Thomas I of 2
RE: J38351 - Walsh Residence
Site Information:
Customer Info: Dave Golden Homes
Lot/Block:
Address: XXX Johnston Road
City: Ft. Pierce
S
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
Seal#
Truss Name Date
Vvi 3 9101
V4 9/10/1
V5 s/10/1
I
8074393 ZEJ5A
8074394 ZEJ7
8074395 ZHJ4
8074396 ZHJ7
8074397 ZHJ10
8074398 ZHJ10A
0/19
0/19
Project Name: Walsh Residence Model: Custom
Subdivision:
State: Florida
2of2
Job toss
ntss Type
Oty
Ply
Walsh Residence
T78074324
J38351 01
Piggyback Base
3
1
Job Reference (optional)
..sr a,oasr puss, rr. nerve, rL J4s4
TRUSS DESIGNED FOR MWFRS ONLY, PER E.O.R. REQUEST. TYPICAL IN THIS JOB.
b
8x8 =
6.00[12
5
d.24U S Jul 14 zu18 MI I6x InCUsmeS, Inc.
4x4 = 6x6
a 7
I Uv:42:tb [U1B
Scale =1:sea
19 1B zb 11 11 10 zo 16 ze 14 13 _
44 = 1,4 II M = 3x8 = Si 3x8 = 5x8 = 2x4 II 4x6
7-1-1 z1.1 I 0.141-1.2t 2aMt1l.-13 41-m 38-1-14 I 420.44-0 51 1�101
Plate Offsets (X Y)-
19:0-3-0 Edge] ry4:0312 0-3-0]
(18:0-2-8
Edoe]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (IOC)
Won
Ud
PLATES GRIP
TOLL 20.0
Plate Grip DOL 1.25
TO 0.54
Ved(LL)
-0.2915-17
>999
240
MT20 244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.95
Vert(CT)
-0.6015-17
>928
180
BOLL 0.0
Rep Stress lna YES
WE 0.84
Horz(CT)
0.17 13
n/a
Na
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 3521b FT=0
LUMBER- BRACING -
TOP CHORD 2x6 SP No.2'Excepl' TOP CHORD
9.12: 2x4 SP 270OF 2.2E
BOTCHORD 2x4 SP No.2'Except*
16-18,14-16: 2x4 SP No.1 BOT CHORD
WEBS 2x4 SP No.3 *Except' WEBS
10-14: 2x4 SP No.2, 10-13: 2x6 SP No.2
OTHERS 2x4 SP ND.3
REACTIONS. (Ib/size) 1=2305/Mechanlml, 13=2868/G-8-0, 11=33/G-3-0
Max Hoa 1=322(LC6)
Max Uplift 1=-187(LC 8), 13=258(LC 8), 11=143(LC 6)
Max Grav 1=2376(LC 13), 13=2884(LC 14), 11=85(LC 18)
FORCES. (Ib)-Max. CompJMax.Ten.-Allforces 250(Ito) or less except when shown.
TOP CHORD 1-2=4524/394, 2-0=3840/406, 4.5=3029/409, 5.6=2628/403, 6-7=2384/388,
7-8=27721399, 8-10=2969/330, 10A 1=0/516
SOT CHORD 1-19=224/4170, 18-19=224/4170, 17-18=1D4/3524, 15-17=0/2652, 14-15=53/2482,
13-14=355/47, 11-13=355/47
WEBS 2-19=0/267, 2-18=731f137, 4-18=0/544, 4.17=1129/193, 5-17=61/894, 6.15=588/65,
7-15=-71/832, 8-15=-333/143, 8-14=522/131, 10-14=103/2921, 10-13=2740/309
Structural wood sheathing directly applied or 3-2-12 ce purling,
except
2-0-0 oc pudins (4-6-9 maxi 5-7.
Rigid ceiling directly applied or 2-2-0 oc bracing.
1 Row at midpt 4.17.6-17.6-15.8-15
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=9.Ops1; BCDL=6.Opsf; h=18ft; B=45ft; L=51ft; eave=6ft; Cat.
II; Exp B; Encl., GCpl=0.18; MWFRS (directional); cantilever left and right exposed; porch right exposed; Lumber DOL-1.60 plate
grip DOL-1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about is center.
5) This truss has been designed for a 10.0 par bottom chord live load noncencurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chard in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift atjoint(s) except (jt=1b)
1=187, 13=258, 11=143.
9) Graphical pudin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
Thomas A. Albani PE No.39300
Iii USA, Inc. FL Cad 6634
9904 Parke East Blvd. Tamps FL 33010
Data:
September 10,2019
®WARNING Vedry design parameters and READ NOTES ON THIS AND INCLUDED MITEx REFERENCE PAGE MIF7473 rev. IOM39015 BEFORE USE.
'-■t
Design valid far use only will MTeM connecwrs. Mils design Is based only upon parameters shown, and Is for an inch idual butiding=mponehd, not
a Wsasynem.Beforeuse,g buildingdesignermustverify NeappU=biftyotdesignpammetemendpmpcMh=ryomte Misdosign Imo Neawmn
��YC
builasildessr. Bracingidi=ted is to prewm boosting a hdMdual Wss web andlor Mom members only. AddNonmtempOmq SMN=Membrechg
Met(
is sways required for slablriy and to prewm catiapm with possible permnal Injury and propemy damage. For general guidanceregard'mg the
fabticRtlon, store9a.delivery. ereNan and bmdrg ofWsses and Wss bst.... re. ANSVTpn Oualay Crlmda, DSB-99 and BCBl Building Component
Seat Parke Fast BW.
SAabinramagon avabbbhen T.u,RM.InWOe,218N.Lee6 M.Sug.31ZAle.d�,VA=14.
Tampa, FL 35610
Job
Truss
Truss Type
Dty
Ply
Walsh Residence
T18074326
J38351
0lA
Piggyback Base
1
1
Job Reference o Tonal
call Uoasl Imsa, r1, nerve, 11.trUn. 11.240 a Jul 14
InG. TUB Sep to 09:22:55 ZU19
Scale =1:90 2
Bxa =
64 = 3x4 1
6.00 12 4x4 =
1iv;
24 23 14 a1 21 20i4 dd 3x8 = 16 15
Asa = 2.4 II Sae =4x6 - 6x10 = 3.4 II 3.4 II 44 = 4a9
axa = 6.10 =
LOADING (list) SPACING- 2-0-0
TCLL 20.0 Plate Grip DOL 1.25
TCDL 20.0 Lumber DOL 1.25
BCLL 0.0 ' Rep Stress Inv YES
BCOL 10.0 Code FBC20171rP12014
CS'.DEFL.
TC 0.74 Ve t(LL)
BC 0.97 VergCT)
WB 0.91 Hoa(CT)
Matrix -MS
in (toe) War L/d
-0.20 21-23 >999 240
-OA6 21-23 -999 180
0.22 15 n/a n/a
PLATES GRIP
MT20 2441190
Weight: 3971b FT=0%
LUMBER- BRACING.
TOP CHORD 2x6 SP No.2 'Except* TOP CHORD Structural wood sheathing directly applied or 3-2-5 oc purlins, except
11-14: 2x4 SP No.2
2-0-0 oG punins (4-6-12 magi 5-8.
BOT CHORD 2x4 SP No.2 *Except' BOT CHORD Rigid Gelling directly applied or 10-0-0Do bracing, Except:
7-20,10-16: 2x4 SP No.3
2-2-0 oc bracing: 23-24,21-23
WEBS 2x4 SP No.3 *Except*
4-11-9 oG bracing: 13-15.
12-17: 2x4 SP No.2, 12-15: 2x6 SP No.2
1 Row at midpt 7-19
WEDGE WEBS
1Row at midpt 4-21.6-21,6-19
Right: 2x4 SP No.3
REACTIONS. (lb/size) 1=2267/Mechanical, 13=377/0-3-0, 15=3317/0-8-0
Max Hoe 1=322(LCG)
Max Uplift 1=-185(LC 8), 13=-496(LC 13), 15=285(LC 8)
Max Grav 1=2276(LC 13), 15=3317(LC 1)
O
FORCES. (lb) - Max. Comp./Max. Ten. -All forms 250 (Ib) or less except when shown.
TOP CHORD 1-2=-4315/389, 2-4=-3626/401, 4-5=28411405, 56=2428/399, 6-7=24621385,
7-8=2467/384, 8-9=2970/465, 9-10=29651357, 10-12=2769/297, 12-13=42/1378
BOT CHORD 1.24=-220/3979, 23-24=-220/3979, 21-23=99/3332, 18-19=0/2417, 17-18=65/2389,
10.17=-732/109. 13.15=1135/100
WEBS 2-24=0/266, 2-23=733/137, 4-23=0/570, 4-21=11521192, 5-21=62t807, 6-21=-406/64,
19-21=0/2502,6-19=-271/84, 8-19=4/724,9-18=-050/151, 10.18=0/359,
15-17=1163/81, 12-17=169/3582, 12-15=-2906/280,8-18=130/495
NOTES.
1) Unbalanced roof live loads have been Considered for this design.
2) Wind: ASCE 7-11% Vuft=160mph (3-second gust) Vasd=124mph; TCDL-9.0psF BCDL=6.0psf; h=18ft; B=45ft; L=51ft; eave=6ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; porch right exposed; Lumber DOL=1.60 plate
gnp DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about 8s center.
5) This truss has been designed for a 10.0 par bottom chord live load nonconcument with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
7) Referto girder(s) for truss to truss Connections.
8) Provide mechanical connection (by others) of Wss to bearing plate Capable of withstanding 100 to uplift at joint(s) except (jt=lb)
1=185, 13=496, 15=285.
Thomas A. Albani PE No.39380
9) Graphical pudin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
MITak USA, Inc. FL Can 6034
69U Parke East Blvd. Tampa FL 331110
Date:
September10,2019
®WARNING- Veiny design parameters and READNOTES ON rHISAND INCLUDED MITEK REFERENCE PAGEMI1-747e rev. fam112015 BEFORE USE.
u■�'
Desgn valid for use onlywah MneMeanneciers. TNs design Is based only Upon parameters shown, and is Wan indMEval buadirg component, not
a decor system. Before use, the building designer mustvelilythe appli abirdyof design parameters and propeM Ncorpo2te this &Np ago the orsrall
��YC
buadingdesgn. Bmeilglndrc edislopm ntNu gelmdMdualWssweba &waordmem we ,. M4WanallemponryandpograneNGacing
MiTek'
is allays required for stabilay and to prevent Collapse with possible personal lnlsay and property damage. Forgeneralguldennoregiu iMMe
fabrication, Norage, delivdyMemun and boxing ofbusses all Was systems.see ANSUTP110ua0ly Crffeda, DS"9 and Ban Building Component
6904 Parke East BNd.
Saraylnromrmlon avalabletram Truss Plate Instaule,219N. Lae Goals. Suite312.AJeOMdrlMVAMI4.
Tampa. FL=10
Job
Truss
Truss Type
Dry
Ply
Walsh Residence
Tt8074326
J38351
02
Piggyback Base
3
1
Job Reference (optional)
test uoasr I was, m vierw, eL we4e B.240 s Jul 14 2019 MTek
Bx8
6.00 12 4x4 = 64 =
6 6 7
Inc. Tue Sep 1U 09:22:592019
25 24 23 32 22 33 34 21 35 20 19 15 14
_ du6 =
qx6 = 2xd II 3x6 =5x8 US= 5xB = 5x5 = 3x4 I 3x4 —
exe = 3x4 =
3x4 II
2x4 It
14.0.2 I 11J 16I I3I 0.20.3 -0 { 45-0-0 4643-0 51-0-0
n
Stale=1.92.6
2A[4
Plate Oftsets(X,Y)-
110:0.3-0,Edgol 117:04-00-1-81118:0.2-120.2-121,120:0.2-80.1-121
121:0-3-80.3-01
LOADING (psf)
SPACING. 2-0-0
CSI.
DEFL. in (loci
Vdefl
L/d
PLATES
GRIP
TCLL 20.0
Plate Gnp DOL 1.25
TC 0.56
VerbLL) -0.30 21-22
-999
240
MT20
244/190
TCOL 20.0
Lumber DOL 1.25
BC 0.95
Ved(CT) -0.6321-22
>885
180
BCLL 0.0 '
Rep Stress Ina YES
WB 0.88
Hors(CT) 0.18 14
n/a
Na
BCDL 10.0
Code FBC2017/3PI2014
Matrix -MS
Weight: 376 lb
FT=0%
LUMBER- BRACING -
TOP CHORD 2xe SP No.2 *Except* TOP CHORD
10-13: 2x4 SP No.2
BOT CHORD 2x4 SP No.2'Exwpt'
9.19,15-17: 2x4 SP No.3, 21-23: 2x4 SP No.1 BOT CHORD
WEBS 2x4 SP No.3'Except' WEBS
11-14: 2x6 SP No.2, 11-18: 2x4 SP No.2
REACTIONS. (lb/size) 1=2312/Mechaniwl, 12=111/0-3-0, 14=2783/0.8-0
Max Horz 1=322(LC 6)
Max Uplift 1=190(1_C 8), 12=163(1_C 8), 14=229(LC 8)
Max Gray 1=2381(LC 13), 12=141(LC 18), 14=2783(LC 1)
FORCES. (III) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 1-2=-4535/399, 24=3850/412, 45=3041/415, 5-6=2639/408, 6.7=2396/394,
7-8=2746/410. 8-9=3189/451, 9-11=32011336, 11-12=0/446
BOT CHORD 1-25=229/4180, 24-25=229/4180. 22-24=108/3534, 21-22=0/2664, 20-21=33/2497,
9-18=-499/177, 17-18=375/40, 12-14=305/2
WEBS 2-25=0/26B, 2-24=731/136, 4-24=0/542, 4-22=-1128/193, 5-22=63/900, 6-21=584/63,
7-21=83/862, 8-21=324/138, 8-20=385/57, 18-20=18/2375, 8-18=107/468,
14-16=2611/227, 11-16=2633/246, 11-18=-143/3159
Structural wood sheathing directly applied or 2-11-4 oc pudins,
except
2-0-0 oc purlins (4-67 max.): 5.7.
Rigid ceiling directly applied or 2-2-0 oc bracing.
i Row at midpt 4-22.6-22.6-21.8-21
NOTES-
1) Unbalanced roof live loads have been Considered for this design.
2) Wind: ASCE 7.10; Vult=160mph (3-second gust) Vasd-124mph; TCDL=9.OpsY BCDL=6.Opsf; h=18ft; B=45ft; L=5111; eave=6ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional): Cantilever left and fight exposed; porch right exposed; Lumber DOL=1.60 plate
grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconCament with any other live loads.
6) - This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
7) Refer to girded(s) for truss to truss Connections.
8) Provide mechanical connection (by others) of truss to beading plate Capable of withstanding 100111 uplift at joint(s) except (p--lb) —
1=190, 12=163, 14=229.
9) Graphical pudin representation does not depict the size or the orientation of the Purim along the lop and/or bottom chard.
Thomas A. Alban! PE No.38380
NiTek USA, Inc. FL Ce116634
69M Parke East Blvd. Tampa FL 33610
Data:
September 10,2019
®WARNING - Voiily tle.Ugnpa nets anJREAD NOTES ON TMS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 mv. 10/aMOIS BEFORE USE.
Design Mkt for use onyw3h MTek®cennectms. This design is based ony upon parameters MINT. and is for an indMdual burning component, not
Veappgrrosswb design pmamelms and inwryarne NV nengn'udoihe overall
a Wsssynign.
is Only. Daring
BeangIndieedIsto arenanermung dir
BaWglndlca Dude wenuryan and/w NoNmembenty
ahIigs
MiTek'
regINdBlDe
with arse Tsonal DroPe e. Forgtlhioniguldarsryardini a
Is mui. and prevent with parse
ked for stability Forgenaffied
W aWad...
ANSM11 , DS
fadetyingrnatio,delivery,erenlonannbratlngofbuse18N. Wsssynemas31 ANSVAP Duality Cdroda, DSaae antl BC5l Building Component
a.m.. reatio and bra ni, of Systems. NO
3a/eylnronnaflon avaDabk emn Trvsa pine lnnaNe, 218 N.Lea soon, Suae312. Alexandria, VA 2231d.
Tampa, FL 36610
Taw-,,. 36610
Job cuss
Truss Type
0ly
Ply
Walsh Residence
T78074327
J38351 03
Piggyback Base
3
1
Job Reference (optional)
East Coast Truss, FL Pierce, FL 34WB
8.240 s Jul 14 2019 MTek Industries, Inc Tue Sep 10 09:23:01 2019
5x5 = _
BOO 12 3x8 = 54
6 a 227
Scale =1:83.0
18 17 ao w 15 ee as 14 se m u u 11
yN = 2x4 II axe = 5FB - 3x8 = 3xB = 30- 3x8M1BSHS =
44 =
7-1-1 14-0.2 20.11J 3041-13 38-0-10 4741-0
z1.1 I 6.n-0 I a-11.1 I &1.m I Bala
Plate Offsets (X Y)-
11:0-0-0 0-1-12] 15:0.2-8 0.2-41 17:0-2-8 0-2-01
LOADING (Pat)
SPACING. 2-0-0
CSI.
DEFL.
in (loc)
Udell
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.89
Vert(LL)
-0.29 14-15
>999
240
MT20
244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.91
Vert(CT)
-0.6214-15
>906
180
M18SHS
244/190
BCLL 0.0 '
Rep Stress lncr YES
WE 0.98
HOR(CT)
0.20 11
n/a
n/a
BCDL 10.0
Code FBC20177rP12014
Matrix -MS
Weight: 3021b
FT=O%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2'Except' TOP CHORD
3.5: 2x4 SP No.1, 1-3: 2x4 SP 270OF 2.2E
BOT CHORD 2x4 SP No.1 BOT CHORD
WEBS 2x4 SP No.3 WEBS
WEDGE
Left: 2x4 SP No.3
REACTIONS. (lb/size) 1=2343/0-8-0, 11=2343/Mechaniml
Max Horz 1=277(LC6)
Max Uplift 1=186(LC 8), 11=191(LC 8)
Max Grev 1=2420(LC 13), 11=2417(LC 14)
FORCES. (lb) -Max. Comp tMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-4522/385, 2-4=3896/402, 4-5=3104/407, 5-6=2695/401, 6-7=2495/383,
7-8=2860/395, 8-9=3014/350, 10-11=255/73
BOT CHORD 1-18=329/4115, 17-18=329/4115„15-17=214/3543, 14-15=-90/2719, 12-14=-143/2606,
11-12=179/2368
WEBS 2-17=652/132, 4-17=0/529, 4-15=1111/191, 6-15=6V945, 6-14=566/70,
7-14=73/921, 8-14=380/138, 9-12=0/518, 9.11=31011240
Structural wood sheathing directly applied, except end verticals, and
2-0-0 oc pudins (3-5-11 max): 5-7.
Rigid ceiling directly applied or 10-0-0Gobracing.
1 Row at midpt 4-15, 6-15, 6-14, 8-14. 8-12. 9-11
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vu8=160mph (3-second gust) Vasd=124mph; TCDL=9.Opst BCDL=6.Opsf, h=18ft; B=45ft; L=47ft; eave=6ft; Cat.
II; Exp B; Encl., GCpl=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) All plates are MT20 plates unless otherwise indicated.
5) Plates checked fora plus or minus 0 degree rotation about its center.
6) This truss has been designed for a 10.0 ps1 bottom chord live load nonconcunent with any other live loads.
7) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
8) Refer to girder(s) for truss to truss Connections.
9) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 IS uplift at joint(s) except N=lb)
1=186. 11=191.
10) Graphical purlin representation does not depict the size or the orientation of the puffin along the lop and/or bottom chord.
Thomas A Alban! PE No.39380
MIT& USA, Inc. FL Cert6634
69M Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING- Vemy design parameters and READ NOTES ON THIS AND INCLUDED MITEx REFERENCE PACE 61114473 rev. lN=015 BEFORE USE.
seasses
Design sned Wass only WNI MTe{®CaMBCIOR. Ws design i3 based arty upon parameters Gunn. and is loran InGNdual bullsol; Component, no
��•
a Wessystem Beforeuse,erabuildingdesignermustwdfymeeppUr Uyofdesignparametersandpmpedyavnrp erandesignhtoMeowmA
boldingdaalgn. Scaring LWicated is to pmwntburkfmg of lndMduel WsswebaMlar NON member onN. AdddionaltempararyaMpmmanent Macldg
MiTek'
Is alsays required for stabilhy and to prevent Collapse wain passible personal injury and property damage. Forgeneralguidanceregardingth,
fabrication.storage. delivery, eradian and bmdn9 oftrusses and trues systems, see ANS17711 opal!,Criteria, D5849 and SCSI Building Component
6904 Padre East BIM.
Sarerylnr4rma11on agaMble hem Truss Hate Indante, 218 N. Lee Stred, Son 31Z Alexendda, VA22314.
Tempe, FL MID
Job Truss
Truss Type
Oty
Ply
Walsh Residence
T76074328
J38351 03A
Piggyback Base
1
1
Job Reference (optional)
... I .. ... L lub, n.r.=...e, 0.24USJun4m1smueK1npusmeS, roc.
i
sxs IIB
8.00 13x42 3x6 =
m us:eo:U"U1s rage I
scale=1:83.D
22 21 zu e1 19 18 ea " 3x8 = 14 13
58=
a4 II Sects = 4x6 6xio = 3x4 II 3x4 II GAS =
6x8 =
7-1-1 I Al . 2 z0.11a I 29-0-0 30-0-13 361b 40.2-0 47-0-0
I la
Plate Offsets (X,Y)—
[I:0.0.0,0-1-121, [5:0-2-8,0-2-01, [8:0.2-8,0-2-01.115:0-5-8,0-0-81,
[17:0.2-0,0-2-121.
f19:0-0-8,0-2-01
LOADING (psQ
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
WEB
Utl
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.94
Vert(LL)
-0.22 19-21
>999
240
MT20 244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.94
Vert(CT)
-0.5218-19
-999
180
BCLL 0.0 '
Rep Stress Ina YES
We 0.97
Hom(CT)
0.25 13
Na
Na
BCDL 10.0
Code FBC20177rP12014
Matrix -MS
Weight: 3421b FT=0
LUMBER- BRACING -
TOP CHORD 2x4 SP No.1'Except' TOP CHORD
5-B,8-10: 2x4 SP No.2, 1a: 2x4 SP 270OF 2.2E
BOT CHORD 2x4 SP No.2 *Except* BOT CHORD
1-20: 2x4 SP No.1, 7-18,11-14: 2x4 SP No.3
WEBS 2x4 SP No.3 'Except* -
13-15,12-15: 2x4.SO No.2 WEBS
WEDGE
Left: 2x4 SP No.3
REACTIONS. (Ib/s¢e) 1=2343/0-8-0, 13=2343/Mechanical
Mail Hoa 1=277(LC 6)
Max Uplift 1=186(LC 8), 13=191(LC 8)
Max Grav 1=2349(LC 13), 13=2343(LC 1)
FORCES. (lb) - Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=4384/385, 2-4 -3746/401, 4-5=2984/407, 5E=2556/401, 6.7=-2673/400,
7-8=2677/400, 8-9=3354/491, 9-11=3353/381, 11-12=3516/340, 12-13=2277/234
BOT CHORD 1-22=330/3982, 21-22=-330/3982, 19-21=-213/3409, 16-17=79/2604, 15.16=-218/3049,
11-15=316/90
WEBS 2-21=653/132, 4-21=0/553, 4-19=1133/190, 5-19=64/884, 6-19=508/58,
17-19=105f2630,8-17=9/746,9-16=-442/153, 12-15=216/3009, 8-16=-146/769
Structural wood sheathing directly applied, except end verticals, and
2-0-0 oc pudins (3-4-12 max.): 5.8.
Rigid Ceiling directly applied or 10-M 0o bracing, Except:
2-2-0 oc bracing: 19-21.
1 Row, at midpt 7-17
1 Row at midpt 4-19, 6-19, 6-17
NOTES.
1) Unbalanced root live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuft=160mph (3-secdnd gust) Vasd=124mph; TCDL=9,Opsf; BCDL=6.Opsf; thief Bit; B=45ft; L=471t eave=6ft; Cat.
II; Exp B; Encl., GCpi=0.IB; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcunenl with any other live loads.
6) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectahgle 3-6-0 tall by 2-0-0 wide
will rd between the bottom chord and any other members, with BCDL = 10.Opsf.
7) Refer to girder(s) for truss to truss Connections.
8) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100111 uplift at joint(s) except 0t=11b)
1=186,13=191.
9) Graphical pudin representation does not depict the sae or the orientation of the pudin along the top and/or bottom chord.
Thomas A Alberni PE N09380
MITex USA, Ina FL Cart 6034
6904 Parke East Blvd. Tampa FL 33610
Data:
September 10,2019
®WARNING -Verify design paminelers and READ NOTES ON TMS AND INCLUDED M19FEK REFERENCE PAGE MIP7473 ree 1WO312015 BEFORE USE.
Design valid Or use only with MireM connsmors. This design is based only upon parameters shown, and Is for an maiddual building component, no
�■'
a truss system. Before use, the bonding designer most way Me applicability of dedgn paramaten and property incorporate Nis desgn into the overall
bwldingdesign. Bracing indfrated is to prewnt hualiIg of mdlvidualbuss web andfor chord members ony.Add'hbnaltemporaryandpermaneNNaGng
MiTek'
Is always required Or stability and to prevent colap gi with possible personal intvy end property damage. For gender guidance regaNing the
Retention, Storage, delivery, erection end bredng of busses and buss systems,see ANSIRMI Duality Crifeda, DSB49 and SCSI Building Comyonea
6904 PaNe East BIM.
SayeylMprmatldn available kom Truss Mate Insidule, 218 N. Lee Street, aude 31Z Alexandra, VAM14.
Tampa, FL 36310
Job
Truss
Truss Type
Oly
Ply
Walsh Residence
T1B074329
J38351
04
Hip
1
1
Job Reference (optional)
Last Doast Truss, Ft. MINUS. FL 3494D
8.240 s Jul 14 2019 MITek Industnes, Inc. Tue Sep 1U 09:23:03 2019
Sx5 =
800 12 3,13 = Sx5 =
5 6 227
Scale=183.0
l�
18 17 io Aa 15 Ar co 14 fA co Al ,A 11
SIB = 2.4 II M = S'B 3,131 = 3x8 = 34 — 3x8 M18SRS =
4x5
7-17.8 14-0-11 I 21-0-0 30-0-0 38-0-0 I 47-0-0
Plate Offsets (X Y)—
(1:0-0-0 0-1-121 (5:0-2-8 0-2-41 (7:0-2-8 0-2-41
LOADING (psQ
SPACING- 2-0-0
CSI.
DEFL,
in (loc)
Year
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.89
Vert(LL)
-0.28 14-15
>999
240
MT20
2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.91
Vert(CT)
-0.6014-15
>932
180
M18SHS
2441190
BCLL 0.0 '
Rep Stress Inv YES
WB 0.99
Horz(CT)
0.20 11
ma
n/a
BCDL 10.0
Code FBC2017rrP12014
Matrix -MS
Weight: 3021le
FT-0%
LUMBER -
TOP CHORD
2x4 SP No.2'ExcepC
3-5: 2x4 SP No.1, 1-3: 2x4 SP 270OF 2.2E
BOT CHORD
2x4 SP No.1
WEBS
2x4 SP No.3
WEDGE
Left: 2x4 SP No.3
REACTIONS. (lb/size) 1=2343/0-8-0, 11=2343/Mechaniml
Max Horz 1=278(LC 6)
Max Uplift 1=186(LC 8), 11-191(LC 8)
Max Grev 1=2419(LC 13), 11=2416(LC 14)
BRACING -
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOTCHORD Rigid ceiling directly applied or 10-0-0oc bracing.
WEBS 1 Row at midpl 4-15, 6-15, 6-14, 8-14, 8-12, 9-11
FORCES. (Ib)-Max. Comp./Max. Ten. -All forces 250(Ile) or less except when shown.
TOP CHORD 1-2=-4520/385, 2-4=-3891/402, 4-5=3095/407, 5b=2687/401, 6-7=-2491/384,
7-8=-2855/396,8-9=3015/351, 10-11=256/73
BOT CHORD 1-18=329/4115, 17-18=329/4115, 15-17=-213/3539, 14-15=89/2711, 12-14=-143/2605,
11-12=179/2371
WEBS 2-17=-6M133,4-17=0/533,4-15=11171191,5-15=-611942, 6-14=-562/69,
7-14=73/920, 8-14=387/139, 9-12=0/515, 9-11=3102/240
NOTES-
1) Unbalanced mot live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf, BCDL=SOpsf; h=18ft; B=45ft; L=471t; eave=6ft; Cal.
II; Exp B; Encl., GCpi=0.18: MWFRS (directional); Cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) All plates are MT20 plates unless otherwise Indicated.
5) Plates checked for a plus or minus 0 degree rotation about its center.
6) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads.
7) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will rrt between the bottom chord and any other members, with BCDL = I O.Opsf.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift atjoint(s) except (#=lb)
1=186,11=191.
Thomas A. Animal PE No.39380
INTO USA, Ina. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING- Verify tlevgn Parameters entl READ NOTES ON THIS AND INCLUDED MITEa REFERENCE PAGE Mll-7473—, 1&0312015 BEFORE USE.
Design valid far use orl arrests eonnedan. This design Is based I n, upon pammden sl,om, and Is bran indMdual Noting mrtgwnen4 no
a Gust system. Before use, the strong desgner mud verify the appgcalliay of tlevgn Parameters and property Incorporate ma dedgn into We owron
bueflul vgn. AOlonaltempOma oMpmmaneson,rig Welk'
Is aNlays required for Stability and to prevent collapse with pestles pemnal rjM and property damage. Forgenerzl guldance regarding the
Iabdptidn, donge,al.W.N, eredion and loading oftmssm end truss sysem;see ANSVTPII Duality Odeerb, DSBd9 and Best Building Component 6904 Parke East BMW.
l Sabrytnbrmadon aviMblehom TrussRMelnMkWa.210N.Lea Sired.aM312,Meaend&.VA=314. Tampa, FL MID
Job Truss
Truss Type
Oty
Ply
Walsh Residence
T18074330
J38351 A05
Hip
1
1
Job Reference (optional)
test Goast i russ, rL rle¢e, rL Y1990 C.z9usdull4Lultlm1lercmauAnes,mc, iue
ID:INmuMgoEcpdh37zliasEOyjN73-RjGdlNwpVGcO7VcHuZFL
6-115 -0-0 24-0-15 I 3B8d+1H0 415r10101077-44261115 5 N146
2-
54 5x6 = Us =
8.00 12
5 6 7
M 21 20 19 16 15 29 14 .,. 13
4zfi
2,4 II SMi WB = 3.4 II 3x4 It 4x10 = sea = 2x4 II 44
SAS =
Scale = 1:90.7
LOADING (par) SPACING- 2-0-0
TCLL 20.0 Plate Grip DOL 1.25
TCDL 20.0 Lumber DOL 1.25
BCLL 0.0 ' Rep Stress Ina YES
BCDL 10.0 Code FBC2017/TPI2014
CSI.
TC 0.73
BC 0.99
We 0.99
Matriz-MS
DEFL. In (hoc) Wall L/d
Vert(LL) -0.21 17-18 >999 240
Ven(CT) -0.64 19-20 >999 180
Horz(CT) 0.30 13 n/a Na
PLATES GRIP
MT20 2441190
Weight: 3751b FT=O%
LUMBER- BRACING -
TOP CHORD 2z6 SP No.2 *Except* TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc puffins.
9-12: 2x4 SP No.2 BOTCHORD
Rigid ceiling directly applied or 2-2-0 Do bracing.
BOT CHORD 2x4 SP No.2'ExcepP WEBS
1 Row at midpt 6-18, 7-15, 8-15
5-19,6-16: 2x4 SP No.3
WEBS 2x4 SP No.3 'Except'
18-20,10-14: 2x4 SP No.2, 10-13: 2x6 SP No.2
OTHERS 2x4 SP No.3
WEDGE
Right: 2x4 SP No.3
REACTIONS. (lb/size) 1=2285/03-0, 13=3100/0-8-0, 11=179/030
Maz Horz 1=-323(LC 6)
Max Uplift 1=187(LC 8), 13=260(LC 8), 11=-293(LC 13)
FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-0354/395, 2-4=3657/404, 4-5=3962/408, 5-6=3412/399, 6-7=3491/396,
73=2673/390, 8-10=2642/315, 10-11=01969
BOT CHORD 1-22=225/3874, 2D-22=225IW74, 5-18=65/1272, 17-18=0/3504, 6-17=262/109,
14-15=-65/2279, 13-14=765/55, 11-13=765/55
WEBS 2-22=0/258, 2-20=749/140, 4-20=889171, 18-20=115/3474; 4-18=0/423, 6-18=397/52,
15-17=0/2606, 7-17=9/2212, 7-15=1202/O, 8-14=729/145, 10-14=120/3143,
10-13=2917/281
NOTES-
1) Unbalanced mot live loads have been Considered for this design.
2) Wind: ASCE 7-10; Vuh=160mph (3-second gust) Vasd=124mph; TCDL=9.0psf, BCDL=6.Opsf; h=18ft; B=45ft; L=5111; eave=6ft; Cat
II; Exp B; Encl., GCpi=D.18; MWFRS (directional); cantilever left and right exposed; porch right exposed; Lumber DOL=1.60 plate
grip DOL=1.60
3) Provide adequate drainage to prevent water podding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconwrtent with any other live loads.
6) -This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide
Will fit between the bottom chord and any other members, with BCDL=10.Opsf.
7) Provide mechanical connection (by others) of truss to beading plate capable of withstanding 100 Us uplift atjoim(s) except Gt=lb)
1=187,13=260.11=293.
Thomas A. Alban! PE No.39390
MiTek USA, Inc. FL Cart 66U
6904 Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING- Venry design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 re✓. hVdV2015 BEFORE USE.
Design vaAl for use ord with Meek® onvocc s. This design is based any upon parameters shown, and is for an Individual Welling component. not
a Wss system. Berge use, Me building designer must w nyme appeoseafty efdesign parameters and property m sureo to this tleop We the owned
boiling deggn. Broome indicated is to beetling M mdivldval buss web andlor Nand mention only. Adi ional temporary and permanent bnncmg
MiTek'
preaeM
is always retu'Ired for Stability and to prevent coAapse with passible personal lnjuryand property damage. ForgenerdguNaMeregardiry Ma
fibnraaan, gunnel, delivery, erec6an and bnndng arvusses and buss syrems. see ANSUIPN Duality Canada, DS"9 and BCS1 Building Conventual
6904 Parke East BNd.
Sarsrylntandi flon available ham Truss Plate Insti 218 N. Lee &red, suds 312 Alexandra, VAM14.
Tampa. M 36610
Job
russ
Truss Type
Oty
Ply
Walsh Residence
T78074337
J38351
O6
Hip
1
7
Job Reference o lional
Dust,'.. I rllss, TL rlelCe, rL J v40
5.24U S JUI 14 ZU19 MI IeR InOUSmes, Inn. 1 ue Sep lU Uv2a:uo LU1 V
6x8 =
6.00 12 2x4 II 6x8 =
5 B 22 7
16 23 2417 16 25 15 26 14 13 21 12 11
3zfi Sx6 = 5x5 we = 3x6 = See = 3x6 = 4x10 = 3xBM16SHS 11
4x6 =
g-7-0 19-0-0 256-0 32-0-0 39-0-0 47-0-0
1 g-7s o-sn aan { B-ILn i T.aa 1 7_7_12
Plate Offsets (X Y)—
[1:0-0-0 0-1-12] [S:0-6-0 0-2-8] [7:0-6-0 0-2-8] [12:0-3-8 0-2-01
LOADING lost)
SPACING- 2-0-0
CSI.
DEFL.
in (too)
Udell
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.96
Vert(L-)
-0.38 16-18
>999
240
MT20
2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.98
Vert(CT)
-OM 16-18
>703
180
M18SHS
2441190
BCLL 0.0 '
Rep Stress Incr YES
WB 0.99
Horz(CT)
0.17 11
Na
Na
BCDL 10.0
Code FBC2017[rP12014
Matrix -MS
Weight: 2911b
FT=0
LUMBER -
TOP CHORD
2x4 SP N0.2'Except'
7-0,1-3: 2x4 SP No.1, 8-10: 2x4 SP 270OF 2.2E
BOT CHORD
20 SP Nc.1
WEBS
2x4 SP No.3
OTHERS
2x4 SP No.3
WEDGE
Left: 2x4 SP No.3
REACTIONS. (lb/size) 1=234310-8-0, 11=2343/Mechanical
Max Horz 1=249(LC 6)
Max Uplift 1=-186(LC 8). 11=191(LC 8)
Max Grav 1=2448(LC 13), 11=2426(LC 14)
BRACING -
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOTCHORD Rigid ceiling directly applied or 2-2-0 DO bracing.
WEBS 1 Row at midpt 4-16, 6-15, 9-13
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=4615/406, 2-0=4300/409, 4-5=3347/406, 5-6=2937/409, 6-7=-2937/409,
7-9=2997/378, 9-10=3055/296, 10-11=2358/228
SOT CHORD 1-18=356/4184, 16-18=244/3644, 15-16=113/2997, 13-15=91/2579, 12-13=174/2625
WEBS 2-18=413/164, 4-18=0/590, 4-16=948/189, 5-16=-36/1000, 5-15=69/351,
6-15=-587/140, 7-15=631785,7-13=0/357,9-12=-595/150, 10-12=169/2647
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-secend gust) Vasd=124mph; TCDL=9.Opsf, BCDL=6.Opsf; hat8ft; B=45ft; L=47ft; eave=6ft; Cat.
II; Expo B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ;'Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) All plates are MT20 plates unless otherwise indicated.
5) Plates checked for a plus or minus 0 degree rotation about its center.
6) This truss has been designed for a 10.0 list bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chard in all areas where a rectangle 3-6-0 tall by 2-0.0 wide
will fit between the bottom chord and any other members, with BCDL=10.Opsf.
8) Refer to girder(S) for truss to truss connections.
9) Provide mechanical Connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (It -lb)
1=186,11=191.
Thomas A. Albert PE No.39380
MiTek USA, Ina FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
September 10,2019
®WARNING-VerirydsV1npaamelen and READ NOTES ON THIS AND INCLUDED MITEK REFERENCEPAGE MR-7473 rev. 10/OL2015 BEFORE USE.
Design valid for use onlyw6h MlTebde connectors. This design is based any upon parameters shown, and Is foran Individual building Companem, not
�■
a truss system. Before use, the building designer must very the app9CabiByof design parameters and prapedy Ncoryomte Nis design MIMI, averaa
buildNgdesign. BredngindmaMdistoprevenlbuCkMgofIndMdualWaswebendlmchartmembersony. Additional temporary and permanundlasong
MiTek'
is always requbed for stabiliyand to prevent Collapse wait possible personal injury and property damage. Forgenew1gukanceregardingthe
MbdCation,5orage,derwery,emWon=dbmdngaIMSMSalp SSsydems,see ANSgr%1DuaMy Cr d.,DSBd9andBCSIBuiMing ComponeM
6904 Parka East BIW.
SareylMarmaBon available fmm Truss %ate Insldme, 218 N. Lee Street, Guile 312, Alexandria, VA22314.
Tampa, FL 36610
Job mss
Truss Type
Oty
Ply
Walsh Residence
T18074332
J38351 7
Hip
1
1
Job Re(erenca notional)
Caswoest Imss, w. rlerce, rIL:we4b
I
tOx10 =
3x4 II sx6 =
6 7 8
am
8.240 s Jul 14 2019
6x8 =
9
Inc, Tue Sao 10 09:23:07 ZU19
25 32 24 33 23 22 19 18 34 17 18 15
See — 3x6 = 54 Vv8 = 3x4 11 3x4 II 4x12 = See = 2x4 II 4x6
ass = Sea
&7-0 19-0.0 21-P151 .6-15 32-00 39-10-0 468-0 51-0-0 1
ti s 24
Scale=1:92.6
C
13j
Pilate Offsets (X,Y)—
(2:0-",0-1-8), (3:0-3-0,Edge), (6:068,0-3-41
[9:0-5-12,0-3-0I (11:0-3-O,Edpel
(16:0-3.80-1-81 [20:0-5-12,0-SOl
121:0-3-4,0-2-121, (23:0-1-8,0.2-81
LOADING (pst)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
gdeg
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.90
Vert(LL)
-0.36 23-25
-999
240
MT20 244/190
TCDL 20.0
Lumber DOL 1.25
BC 1.00
Vert(CT)
-0.83 23-25
>675
180
BCLL 0.0
Rep Stress Ina YES
WB 0.97
Hoa(CT)
0.43 15
n/a
n/a
BCDL 10.0
Code FBC20177TPI2014
Matrix -MS
Weight: 375111 FT=0%
LUMBER -
TOP CHORD
2x6 SP No.2'ExcepC
1-3: 2x4 SP No.1, 11-14: 2x4 SP No.2
BOTCHORD
2x4 SP No.1 'Except*
7-22,8-19: 2x4 SP No.3, 20-21,13-17: 2x4 SP No.2
WEBS
2x4 SP No.3'Except'
6-23,21-23,9-18:2x4 SP No.1, 6-21,12-16:2x4 SP No.2
12-15: 2x6 SP No.2
OTHERS
2x4 SP No.3
WEDGE
Left: 2x4 SP No.3, Right: 2x4 SP No.3
REACTIONS. (Ib/size) 2=236210-8-0, 15=3473/0.8-0, 13=52110-3-0
Max Horz 2=298(LC 7)
Max Uplift 2=241(LC 8), 15=268(LC 8), 13=652(LC 13)
BRACING -
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD
Rigid ceiling directly applied or 1-4-12 oc bracing.
WEBS
1Row at midpt 5-23,9-18
2 Rows at 1/3 Pis 6-23
FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4-4211/401. 4-5=3875/402, 5.6=3023/404, 6-7=3726/403, 7-8=-3746/403,
8-9=3930/420, 9-10=2613/372, 10.12=2223/294, 12-13=1111698
BOT CHORD 2-25=232/3856, 23-25=129/3347, 20-21=22J3944, 8-20=3631106, 16-18=-61/1897,
15-16=1412/74, 13-15=1412g4
WEBS 4.25=387/157, 5-25=01554, 523=987/189, 6-23=3300/0, 21-23=0/4984,
6-21=32/4285, 8-2 1 =-529/37, 18-20=012368, 9-20=61/2384, 9-1 8=1 025/29,
10-18=0/534, 10-16=-1025/144, 12-16=-143/3484, 12-15=3268/274
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuh=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf; BCDL=6.OpsY h=1Bit B=45ft; L=51ft; eave=6R; Cat.
II; Exp B; End., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; porch right exposed; Lumber DOL=1.60 plate
grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This tmss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will rd between the bottom chord and any other members, with BCDL = I O.Opsf.
7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 Ib uplift at joint(s) except at --lb)
2=241, 15=268. 13=652.
Thomas A Albani PE No.39380
MiTek USA; Inc FL Can 6634
6304 Parke East Blvd. Tampa FL 33610
Data:
September 10,2019
®WARNING- Verily design paramelen and READ NOTES ON THIS AND INCLUDED MITEx REFERENCE PAGEM117413 mv. 101MOI5 BEFORE USE.
�■�
Desgn valid fofuse onVwab %TeM cmnectan. This design is based ant, upon parameters Mown, and is for an IadivNAYM building component, not
a "as system, Bolder use, the building desgnermust wielder eppUsatny of des, parameters end property Incorporate this design one ibe osarali
x0dingdesgn. BmdngbMicstedlstopmmtWck gothdIVdal VusswebendloraoNmembenony. AddbbnellemporayandpennanelM1brocing
M7ek'
Is always regulerd for Mabis,, and to prevent collapse whin possible personal injuryend property damage. ForgenerAguidancoregamingthe
fabrication, storage. dehvery, erection and bmdng almases and Was systems.sea ANSI/TPII Quality Cnehi, DSB4ss and BCS1 Building Component
6904 Pans East BIM.
Safetylefolmaaon availablefrom Tmas Pieta Ind4.t..218N.LeeS M,Suha31ZAlex dM.VAM14.
Tampa,FL MID
Job
Truss
cuss Type
Oty
Ply
Walsh Residence
T78074333
J38351 J.
Hip
1
1
Job Reference o tional
i
ID:INmub4goEcpdh37zljasEOyjN73-KU WBbt
17-0O 22-8-0 28 3460 I 40
57-5 5-8-0 5-&0 5-e-0 6
6.00 12 5x5 = Sx5 =
3x8 = 3x8 =
5 22 6 7 23 8
na. raw uey se w.w.uamn rage)
11
Scale=1:84.3
16 24 25 17 16 26 27 15 28 14 29 13 12 11
5x8
Sang US w8 = 3x6 = 5x6 WS = 3x8 = 4x10 = 3x6 M18SHS II
=
3x8 =
254i-0 34-00 40-4-4 4]-0-0
A.SO R-511
I$
Plate Offsets (X,Y)—
tt:D-D.o D-1-12) I5:6-2-e D-2rt 18:0-2-e D-2-4) 112:6-3-8 6-2-0)
LOADING (psf)
SPACING. 2-0-0
CSI.
DEFL.
in (loc)
gdeft
Lid
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.90
Vert(LL)
-0.29 1&18
>999
240
MT20
2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.98
Vert(CT)
-0.66 16-18
>653
180
M18SHS
244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.95
Horz(CT)
0.19 11
BIB
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 290 lb
FT=0
LUMBER -
TOP CHORD
20 SP No.2 *Except*
1-3:.2x4 SP No.t
BOT CHORD
2x4 SP No.t
WEBS
20 SP No.3
OTHERS
2x4 SP No.3
WEDGE
Left: 2x4 SP No.3
REACTIONS. (Ib/size) 1=2343/0-8-0.11=2343/Mechanical
Max Horz 1=220(LC 6)
Max Uplift 1= 186(LC 8), 11=191(LC 8)
Max Grav 1=2430(LC 13). 11=2367(LC 14)
BRACING.
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
2-2-0 oc bracing: 1-18.
WEBS 1 Row at midpt 4-16, 6-16, 6-15, 7-13
FORCES. (lb) - Max. Comp./Max. Ten. -AU forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-4587/403, 2-4=4315/407, 4.5=3521/404, 5-6=-3092/392, 6-7=-3232/399,
7-8=2614/358, 8-9=3004/364, 9-10=2841/281, 10-11=2298/224
BOT CHORD 1-18=361/4141, 16-18=264/3707, 15-16=177/3337, 13-15=-165/3146, 12-13=-171/2445
WEBS 2-18w-W/143,4-18=0/467,4-16=-818/170,5-16=70/1149,6.16=-562/56,7-15=0/487,
7-13=1043/98, 8-13=-46/915, 9-13=41/312, 9-12=728/139, 10-12=169/2506
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; VuK=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf, BCDL=6.Opst, h=18fl; B=45ft; L=47ft; eave=6ft; Cm.
II; ESP B; Encl., GCpi=0.18; MWFRS (directional): cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) All plates are MT20 plates unless otherwise indicated.
5) Plates checked for a plus or minus 0 degree rotation about 8s center.
6) This truss has been designed for a I O.O pelf bottom chord live load nonconcument with any other live loads.
7) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with, BCDL = I O.Opsf.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except tjt=lb)
1=186, 11=191.
Thomas, A. Allured PE No.39380
MITek USA; Ina FL C,It 6634
6904 Parts East Blvd. Tampa FL 33610
Bate:
September 10,2019
®WARNING -Vef fy design parameters and READ NOTES ON MIS AND INCLUDED MITEK REFERENCE PAGE Mh7473 rev, ipNbt015 BEFORE USE.
R
Design valid for use onlywah MTekdbconnectors. This design Is based only uponpaamners shown, and Is Man indivMual buadilg compeem, rim
�e•
a truss system. Were use, the building designer must vent' We aplAosli y ofdesign parameters and papery lneoryorre OM design mtothe overall
buldingdesign. BmWgiMiWedisWpmnMWcxangdMiMuallassWMarM aoMmembemone. Additional tempaary aM pennaneM Gaging
rs��-��.YYY■
MtTek'
is always ux tied for stabitily, andto prevent collapse with passible peraenal Mjuryand property damage. Fbr9eneralguidarlcelegaMing Me
Iabdtation, Storage, delivery, erection and bmang mbusees and truss symems,see ASBYTRI Qualify Cromer, DS"9 and SCSI Sugdrng Component
6904 PerVe Fast Blvd.
Safefylnraraaffdn ara9able M1mn Truss Plate Inm6me, 216 N. Lee Slrem, Sutle 312, Alexandria, VA 22314.
Tampa. FL 35610
Job as
Truss Type
pry
ply
Walsh Residence
Tf 0074334
J38351 09
Hip
1
1
Job Reference (optional)
6.24U 5 JU114 2U19 MI I ex InaUStneS, Ina. I Ue Sep 1U Ua:2U:IU 2019
Scale =1:84.2
5x5 =
6.00 12
3x6 = see = $x5
9 1030 11
26 25 22 21 20 16m a4 1e m 1116 15 14
4x6 = 3x4 II 3x4 It SA = 3x8 = 5aS Via - 34 - 3x8 = 4x10 = 3.4
7x10M18SHS = 4x6 =
3x8 = 6x10M18SHS =
2-2-0 -10-0
24]-0 5-0-0 58-0
86-0
BE-0
e-051 &7-12
Plate Offsets (X,Y)-
[2:0-0-0 0-1-0I [7:0-5.7 0-2-01 f8:0-2-8 0,2-0)
f11:0.2-8 0.2-4] ry5:038
0-2-01[23:0-440-3-0) [24:0-7-8 0-3-8]
126:0-3-8
0-1-8]
LOADING (psf)
SPACING- 2-M
CSI.
DEFL.
in (lac)
VdeO
Lid
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.88
Vert(LL)
-0.33 18-20
s999
240
MT20
244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.96
Ven(CT)
-0.7918-20
-711
180
MI8SHS
244tl90
BCLL 0.0 '
Rep Stress Ina YES
WB 0.94
Horz(CT)
0.32 14
n/a
me
BCDL 10.0
Code FBC2017rrP12014
Matrix -MS
Weight: 321 lb
FT-0%
LUMBER.
TOP CHORD
2x4 SP N0.2'Except'
1-6: 2x4 SP No.t
BOT CHORD
2x4 SP No.2'Except'
2-25,23-24: 2x4 SP 270OF 2.2E, 17-19: 2x4 SP No.1
WEBS
2x4 SP No.3'Except-
21-23,24-26.3-24: 2x4 SP No.2, 13-14: 2x6 SP No.2
OTHERS
2x4 SP No.3
WEDGE
Left: 2x4 SP No.3
REACTIONS. (lb/size) 2=2447/0-8-0.14=233710-8-0
Max Horz 2=228(LC 7)
Max Uplift 2=240(LC 8), 14=189(LC 8)
Max Grav 2=2467(LC 13), 14=2341(LC 14)
BRACING -
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 1 Raw at midpt 7-20. 9-20. 9-18, 10-16
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 23=3914/288, 3-4 -8283/689, 4-5=6157/533, 5-7�6090/623, 7-8=-3414/403,
8-9=2996/390, 9-10=3168/395, 10.11=2563/355, 11-12=2946/361, 12-13=2785/277,
1314=2272/224
BOT CHORD 2-26=-301/3545, 25.26=47/544, 24-25=-14258, 4-24=146/1989, 23-24=651/7781,
5-23=-339/123, 21-22=28/515, 20.21=249/3592, 18-20=175/3262, 16-18=163/3086,
15-16=-169/2399
WEBS 4-23=-2363/207, 21-23=-225/3131, 7-23=-280/2604,7-21=.499/107, 7-20-802/151,
8-20=71/1107, 9.20=576/54, 10-18=0/472, 10-16=1026/96, 11-16=43/888,
12-16=-28/317, 12-15=728/138, 13-15=-166/2461,3-26=2484/245,24-26=303/3573,
3-24=334/4012
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf. BCDL=6.Opsf, h=18ft; B=45ft; L=47ft; eave=6ft; Cat.
II; ESP B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed: Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) Plates checked for a plus or minus 0 degree rotation about 8s center.
6) This truss has been designed for a 10.0 par bottom chard live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6.0 tall by 2-0-0 wide
will 5t between the bottom chord and any other members, with BCDL = 10.Opsf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except (jl=lb)
2=240,14=189.
Thames A. Alban) PE No.39380
MiTeh USA, Ina FL Cart 8634
6904 Parke East Blvd. Tempe FL Still
Date:
September 10,2019
®WARNING. Verity design parameters and READ NOTES ON THIS AND INCLUDEDMITENREFERENCE PAGE M11.7473rev. I"Mu159EFORE USE.
Make valid W YN ColywRll MTeh®CMnCt09. TUS design Is based" uparparame ins Shown. and IS Wan IMI tival building Mnlp]ne r. net
�■
e`
a buss sypem. Berme use, the bidding designer must Willy Ne appOcabil yof design parameters and propeM reentering Ina design elect. Overall
buiNingdesign. gracing lMicited is to prowit buckling of lndirtdual Wss web Singer Mow members any.Additionaltempomnyandpennanedbeaung
MiTek'
Is always required for Mabily and to prewN CO9Opse wM possible personal mWend property damage. For gana a guldan<a regardim Dle
raterison, Storage. delivery,erection and bRUng efmisses and cuts "ides,gee ANSVTPIf Duality Cradda, DS"llossd BCSIBullding Componerrt
69D4 Parke Fast Blvd.
Selafy okand mi4n avegable from Tmas Plata InsWule, 218 N. Lea SlrGel. Sune312. Alexantlda, VA21314.
Tampa, F 36610
Job
Truss
Truss Type
Qty
Ply
Vyatsh Residence
T18074335
J38351
A09G
Hag Hip Girder
1
Job Reference (optional)
Truss, Ft. Pierce, FL 34946
8.240 s Jul 142019 M7ek Industries, Inc. Tue Sep 10 09:23:16 2019 Page
ID: INmub4goEcpdh37zljasE0yjN73-0gRn3B3iwe?ggBxO1 NywlH980mvzgV5o5L?moNvf4Ef
NOTES-
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joinds) except T=lb) 15=1856, 2=1725.
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 181 Ib down and 142 Ib up at 7-0.0, 179 Ib down and 1351b up at
9-0-12, 1791b down and 135 Ito up at 11-0-12, 179 lb down and 135 It, up at 13-0-12, 1791b down and 135 It, up at 15-0-12, 1791b dawn and 1351b up at 17-0-12, 179
lb down and 1351b up at 19-0-12, 179 lb dam and 135 lb up at 21-0-12, 17916 dam and 135 lb up at 23412. 179 lb down and 135 Ili up at 25-0-12, 179 lb down and
135 Ill up at 27-0-12, 179 lb dawn and 135 Ill up at 29-0-12. 179 lb down and 1351b up at 31-0-12, 179 lb down and 135 lb up at 33-0-12, 179 Ito down and 135 Ito up at
35-0-12, 1791b dam and 135 Ib up at 37-0-12, 179 lb doom and 135 lb up at 39-0-12, 179 lb down and 1351b up at 41-0-12, and 17911a down and 135 lb up at 43-0-12,
and 179 lb dam and 135 lb up at 45-0-12 on top chord, and 408 lb dam and 3161b up at 7-0-0. 98 It, down and 80 to up at 9-0-12, 98 Ib dawn and 8016 up at 11-0-12,
98 It, dawn and 801b up at 13-0-12. 98 lb down and 801b up at 16-0-12, 98 lb doom and 80 lb up at 17-0-12, 98 Ill dam and 801b up at 19-0-12, 98 lb down and 80 lb
up at 21-0-12, 98 lb down and 80 to up at 23-0-12, 9810 doom and 80 lb up at 25-0-12, 98 Ill down and 80 Ill up at 27-0-12, 98 Ill down and 8016 up at 29-0-12, 98 lb
dawn and 80 to up at 31-0-12. 98 lb dam and 80 lb up at 33.0-12. 98 lb down and 80 la up at 35-0-12. 98 to dawn and 80 lb up at 37-072, 9816 down and 80 to up at
39-0-12, 98 lb dawn and 80 No up at 41-0-12, and 98 lb doom and SO It, up at 43-0-12, and 98 lb down and 80 to up at 45-0-12 on bottom chard. The design/selection of
such Connection device(s) is the responsibility of others.
LOADCASE(S) Standard
1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pif)
Vert: 14=-80, 4-14=-80, 15-27-20
Concentrated Loads (Ib)
Vert 4-163(F) 7=163(F) 25= 408(F) 6=163(F) 22=-74(F) 20-74(F) 9-163(F) 17-74(F) 12=163(1`) 11-163(F) 19-74(F) 30-163(F) 31-163(F) 33-163(F)
34=163(F) 36-163(F) 37-163(F) 38-163(F) 39-163(F) 40=163(F) 42=163(F) 43=-163(F) 44=163(17) 45=163(F) 46=163(F) 47=74(F) 48=74(1`) 49=74(F)
50=-74(F) 51-74(F) 52-74(F) 53-74(F) 54-74(F) 55=-74(F) 56=74(F) 57=74(F) 58=74(F) 59=74(F) 60=74(F) 61=-74(F)
®WARNING Verify design Parameters and READ NOTES ON THISANGINCLUDEDMITEx REFERENCE PAGE114I14473rev. 1O1is]/2015 BEFORE USE.
seree
Design until Musa onywidt bhTeditcomenst. True design is based any upon paametea shwm, and is for an IMINdual Mang commando. ram
a truss system Bella use. the building desyner must verifying appribirrty raof design parameters and property soundings, fins design brio me ovean
building design. Bmi Lgicated is to prmnst buckling ofsdMdualtmsswebmnd oedme"emany. Madinat temporary and pemmnea beating
M(Tek•
Is always required for Stability and to prevent collapse with possible personal Inlury, and property damage. Far general guidance regarding the
fcrifaon.Usage. d04VMy, aRtllan and loafing M missing and mus. systems, fen ANSVTPIf Duality CMeds, DSBAS and Best Building Component
6g0/ Parke Eat BIM.
Safefylnfimushid avarbblefrom Tags, Plarolns0Me.218NLae Sheel.Suda312.Nexandde VA]2314.
Tampa, FL 36610
Job
TType
pry
Ply
Residence
T78074336o
Hu
ip
1J38351
1Walsh
Job Reference (optional)
I
P.Avvsuw ivaromunrc inausnias, me iue pep lv
6.00 12 Sea 2.4 II 3x8 =3x8 =
- -Sx5 =
11
Sole -1:82A
19 1s if 25 16 26 15 14 2T 13 12 11
5x8 = 2x4 II 4x8 = 3x8 = 2x4 II Son 3x8 = Axis = 3x8M18SHS II
34 =
z7-7m-0 1
22-0-9 I 28-11-7 I 38-0-0 I 41-0-0 I 47-0-0
zsn
Plate OBsets(X,Y)—
[1:0-0-0,0-1-121 f4:0-6-0,0-2-8) [8:0-2-80-2-4( 112:0-3-80-2-0)
LOADING (pso
SPACING- 2-0-0
CSI.
DEFL.
in (too)
Udell
Lid
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.98
Vert(LL)
-0.22 16-18
-999
240
MT20
244MSO
TCDL 20.0
Lumber DOL 1.25
Be 0.90
Vert(CT)
-0.5316.18
>999
180
MIBSHS
244/190
BCLL 0.0 '
Rep Stress Ina YES
WB 0.93
Homer)
0.20 11
n/a
n1a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 2811b
FT=0
LUMBER -
TOP CHORD 2x4 SP 270OF 2.2E'Excepl'
4.6,6-8: 2x4 SP No.1, B-10: 2x4 SP No.2
BOTCHORD 2x4SPNo.1
WEBS 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3
REACTIONS. (Ib/size) 1=2343/0-", 11=2343/Mechanical
Max Horz 1=191(LC 6)
Max Uplift 1=186(LC 8), 11=191(LC 8)
Max Grav 1=2385(LC 13). 11=2360(LC 14)
BRACING.
TOP CHORD Structural woad sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 2-18, 7-13
FORCES. (Ib) - Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-0448/390, 2A=3707/395, 4-5=3659/430, 5-7=-3659/430, 7-8=2624/341,
8-9=2993/350,9.10=2674/261, 10-11=-2300/218
BOT CHORD 1-19=330/3985, 18-19=-330/3985, 16-18=184/3289; 15.16=-207/3521, 13-15=207/3521,
12-13=166/2309
WEBS 2-19=0/267, 2-18=802/165, 4-18=0/623, 4-16=57/817, 5-16=583/142, 7-16=24/337,
7-15=01366, 7-13=1407/109, 8-13=38/894, 9-13=19/475, 9-12=844/136,
10-12=170/2435
NOTES-
1) Unbalanced roof live loads have been Considered for this design.
2) Wind: ASCE 7-10; Vuh=160mph (3-second gust) Vasd=124mph; TCDL=9.Ops/; BCDL=6.Opsf; h=18ft; B=45ft; L=47ft; eave=6ft; Cat.
II; Exp B; Encl., GCpi=0.18;MWFRS (directional); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates ere MT20 plates unless otherwise indicated.
5) Plates checked for a plus or minus 0 degree rotation about 8s center.
6) This truss has been designed for a 10.0 psf bottom chord live load noncencunent with any other live loads.
7)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas Where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = I O.Opsf.
8) Refer to girder(s) for truss to truss Connections.
9) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) except (t=lb)
1=186, 11=191.
Thomas A. Albani PE Na,39360
l iTak USA, Inc. FL Cert 6034
G904 Parke East Blvd. Tempo FL 33610
Date:
September 10,2019
®WARNING- Verify da.ign Panmelers antl READNOTES ON THIS AND INCLUDED MITEx REFERENCEPAGE M147473 re¢ 10MV2015 BEFORE USE.
Oeslgn valld br use pNywM MrrekW wnmd0n. T M design is based ony upon panmden shown, and is for on in6vkual W90ing mmyonem, not
���•
a met "am Bo oa use, the bwffding deSgnm must wmyMo appllcsoft oldesign pammelen end,ope ly Noo panda Nis design Coto the overall
building design. Baling indicated lsto prevent buckling or Mombiai msa web and(crOo lmmmbers any. AddNonal tempomq and pemmeatamong
MiTek'
b always re4u"ved for stability and to prewnt w9apse wM possible personal injury and property damage. Far gene el guidance rega sing the
febdoetlon, storage. delivery, erection and bracing armless and truss systems, see ANSI?PII Duality Cdbda, DSH49 antl SCM Building Component
6904Padre EaslByO.
Samtylnfenandom awaablerumTrussPlate InMW9,218N.Leg6 O.Sufte312A1ex dO.VA2=14.
Tempt. FL 36610
Job
Truss
Truss Type
Qty
Ply
Walsh Residence
T78074337
J38351
11
Hip
1
1
Job Reference (optional)
Last Coast hies, I-L ele1Ce, FL la49Md
�1
8.240 s Jul 14 2019 MTek Industries. Inc. Toe
Scale=1:84.3
3x6
8.00 12 5x8 = 2x4 II 3x6 =
Sx8
5 24 6 7 8 25 9
20 19 le 4b 17 11 16 'o Ae 14 13 12
5x6 = 2x4 11 4x6 = 3xB = axe =4x6 34 = 4x8 = 3x8 MmSHS, II
3x5 =
]-]-0 I 15-0-0 22-0-9 2&11-7 I 364)-0k 41-0-0 I 47-0-0
iT_1b
Plate Offsets(XY)—
12:0-0-00-1$ f5:0-6-00-2-8) f9:0-6-00-2-8)
f13:0-3-80-2-01
LOADING (psf)
SPACING- 2-041
CSI.
DEFL.
in (loc)
Well
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 1.00
Vert(LL)
-0.23 17-19
>999
240
MT20
244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.98
Vert(CT)
-0.5416-17
>999
180
M18SHS
2441190
BCLL 0.0 '
Rep Stress Ina YES
WB 0.98
Hoa(CT)
0.20 12
n/a
Na
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 2831b
FT=0%
LUMBER- BRACING -
TOP CHORD 2x4 SP 270OF 2.2E'Excepr TOP CHORD
5-7,7-9: 2x4 SP No.t, 9-11: 2x4 SP No.2 BOT CHORD
BOT CHORD 2x4 SP No.1'Excepr
15-18: 2x4 SP No.2 WEBS
WEBS 2x4 SP ND.3
WEDGE
Left: 2x4 SP No.3
REACTIONS. (lb/sme) 2=2451/0-8-0, 12=2341/Mechanical
Max Horz 2=200(LC 7)
Max Uplift 2=241(1-13 8). 12=190(LC 8)
Max Grav 2=2481(LC 13), 12=2366(LC 14)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-0414/379, 3-5=3684/391, 5-6=3632/427, 6-8=-3632t427, 8-9=3433/412,
9-10=-3006/348, 10-11=2682/260, 11-12=2306/217
BOT CHORD 2-20=319/3953, 10.20=319/3953, 17-19=-18113269, 16-17=-205/3487, 14-16=-13112576,
13-14=165/2316
WEBS 3.20=0/263, 3-19=787/156, 579=0/618, 5-17=58/818, 6-17=583/142, 8-17=23/334,
8-16=846/165, 9-16=109/1353, 10-14=19/481, 10-13=852/136, 11-13=169/2442
Structural wood sheathing directly applied, except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
2-2-0 oc bracing: 2-20,16-17.
1 Row at micipt 3-19
NOTES -
I) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vu0=160mph (3-secend gust) Vasd=124mph; TCDL=9.Opsh BCDL=6.0psf; h=18ft; B=45ft; L=47ft; eave=6ft; Cat.
II; ESP B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water Footling.
4) All plates are MT20 plates unless otherwise indicated.
5) Plates checked for a plus or minus 0 degree rotation about Its center.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcu0ent with any other live loads.
7) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will rn between the bottom chord and any other members, with BCDL = 1 O.Opsf.
8) Refer to girder(s) for truss to truss Connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Ot=lb)
2=241, 12=190.
Thomas A. Albanl PE No.39380
MIT&USA, Inc. FL Carl 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING- Vsnfydasign P.rsUa.k rs and READ NOTES ON THIS AND INCLUDED "TEKREFERENCE PAGE 111II4473 re¢ 1N0312015 BEFORE USE.
Design valid for use any was mareea connectors. Thu design Is based only upon pia m sers shown, and iamran inditiUual Waling wmponeM, not
��•
a muss syslem.Before use, Me building designer mud verify the applicabildy of design parameters and property gcorporale Ws design We the oveMl
buildingdesign. BmhgiMicatedistopre tWWhgdMdmdUWl nwc WN"dOdmemb m"y. AddabnaltempararyandpennaaeGtenxNg
MiTek'
I..Maya re .Md roc slebigy onto p.M collapse wim possiNe pemml Injury and property damage. For genets guldanw re8mding the
fabdca8on, dorsge,delivery,emdion and brsdng of WzuaaM truss systems,sea ANSITPII Ouo[*CMeffa, DS8a9 end BCS1 Building Component
6904 Parka East Blvd.
Salorylahanestlon available 8om Truss Plate Ins ae, 218 N. toe Blmd. Sude 312, AlexandM. VA2=14.
Tampa, FL 36610
Job
Truss
Truss Type
0ty
Ply
Wotan Residence
T18074338
J38351
Al2
Half Hip
1
1
Job Reference (optional)
se
14
u.LVu s Jun4 Luta mn eK mausmes, Inc. I us Sep 1 V ue:Ls:iu Lune
Scale=1:82.a
Sx8 — 34 =
2x4 II 3x6 = 3x8 = 3x8 = 2x4 II 4x8 =
errs 3 22 4 5 6 23 7 824 9 10
18 17 15 15 25 26 14 1327 28 12 29 it
5xe = 2.4 II 3x8 = 4A — 3x8 = 3xa = 4,10 = 3AM18SHS II
5x6 M =
6-71 13-0-0 19-8-14 2&104 39-11-00 47-0-0
67-0 a.:M I aA1d I 1M11F I 1M11F I ]N
Plate Offsets (X,Y)—
[I:0-0-0,0-1-121. (3:080,0-2-81
LOADING (pat)
SPACING- 2-0-0
CSI.
DEFL.
in (too)
Udeff
Lid
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.98
Vert(LL)
-0.32 14-15
>999
240
MT20
244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.94
Vert(CT)
-0.7614-15
>735
180
M18SHS
244/190
BCLL 0.0 '
Rep Stress Ina YES
WE 0.78
Hoa(CT)
0.19 11
Ora
We
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 2741b
FT=0%
LUMBER -
TOP CHORD
2x4 SP No.2 *Except*
1-3: 2x4 SP 270OF 2.2E, 3-5: 2x4 SP No.1
BOT CHORD
2x4 SP No.1 'Except*
13A 6: 2x4 SP 270OF 2.2E
WEBS
2x4 SP No.3 'Except'
10-11,6-15,7-12,10-12: 2x4 SP No.2
OTHERS
2x4 SP No.3
WEDGE
Left: 2x4 SP No.3
REACTIONS. (lb/si2e) 1=2343/0-8-0, 11=2343/Mechanical
Max Horz 1=248(LC 8)
Max Uplift 1=-170(LC 8), 11=207(LC 8)
Max Gmv 1=2398(LC 13), 11=2426(LC 13)
BRACING.
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 1 Row at midpt 10-11, 6-15. 7-12
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-0496/351, 2-3=3910/361, 3-0=4159/394, 4-6=-4159/394, 6-7=3924/326,
7-9=-2165/184, 9-10=2165/184, 1D-11=2311/236
BOT CHORD 1-18=-477/3970, 17-18=-477/3970, iS17=356/3431, 14-15=393/4161, 12-14=-322/3493
WEBS 2-17=624/137, 3-17=01503, 3-15=53/1145, 4-15=-574/141, 6-14=598/151,
7-14=-8/964, 7-12=1878/196, 9-12=595/151, 10-12=254/3002
NOTES-
1) Unbalanced mof live loads have been Considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=9.0psf; BCDL=6.Opsf; h=18ft; B=45ft; L=4711; eave=6ft; Cat.
II; Exp B; Encl.. GCpi=0.18; MWFRS (directional); Cantilever left and fight exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) All plates are MT20 plates unless otherwise indicated.
5) Plates checked for a plus or minus 0 degree rotation about its center.
6) This truss has been designed for a 10.0 par bottom chord live load nonconcument with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fn between the bottom chord and any other members, with BCDL = I O.Opsf.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical Connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=170, 11=207.
Thomas A Albert PE No.39380
MiTek USA, Inc. FL Cat 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING - Venrydesign Paramaten anOREAD NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MIb7473 rev. 1OVY2015 BEFORE USE.
Design valid Uruw ontywan MITe®cwneeors. Tbis design is bases only upon pammelers shown, and is swan Indwiduai Wading wmpmwm, nth
FUR
a truss system. Before use, the building designer must vent' me appDarairuyof design parameters and properly incaryoatelNs design "a the overall
buildNgdesign. Bracing Indicated late prevent buckling ofmdiNdual truss web andlw drom members ony. ADdraonaltemposeryandpermaneadaming
M!Tek'
Is always required for sm Alfty and to prevent whales with possible personal inluryand property damage. Forgeneal guidsrloe rega sing the
fabnrsimi storage. delivery, creches and baang oftmsses and truss ayslems.see ANSY7711 Quality Crifwra, DSBJI9 and Best Building Component
6984 Parke Fast BNd.
Safetyfnyormatlan avaLblefrom Truss Mae lnarsite,218 N. Lee asset. sale 31Z Alexandria, VA22314.
Tampa. FL Seale
Job toss
Truss Type
Oly
Ply
Walsh Residence
T18074339
J38351 13
Hip
1
1
rah Rafnm rolnM'r,ne1
11
5x5 =
4
0.49U 5 JYI IY GY I V call l UA
3x8 =
3x6 = 3x8 = 34 =
23 5 6 7 24 8 25
S 6 =
9
Scale=1:SlA
19 18 1126 21 'le 2B 29 15 14 30
13 12
2x4 II 3x8Ml8SHS = 3xfi = 3xe = 3x8 = 3aB =
Sx6 = 3x8 = 5x6 WB =
6-7-0 13-0-0 21d0 29b-0 I 384).(1 474)-0
a_7n r`Kn
I�
Plate Offsets (X Y)—
[2:0-0-0 0-1-81 f4:0-2-8 0-2-41 [9:0-2-8 0-2-01
LOADING (pelt
SPACING- 2-0-0
CSI.
DEFL.
in (foe)
I/deb
ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.82
Vert(LL)
-0.27 15-16
>999
240
MT20
244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.89
Vert(CT)
-0.6615-16
>847
180
M18SHS
244/190
BCLL 0.0 '
Rep Stress Ina YES
WB 0.74
Horz(CT)
0.19 12
File
n/a
BCDL 10.0
Code FBC20177rP12014
Matrix -MS
Weight: 2731b
FT=O%
LUMBER.
BRACING -
TOP CHORD 2x4 SP No.2'Excepr
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc pudins,
1-4: 2x4 SP 270OF 2.2E
except end verticals.
BOT CHORD 2x4 SP 2700F 2.2E'Except'
BOT CHORD
Rigid ceiling directly applied or 160-0 oc bracing.
1417: 2x4 SP No.t
WEBS
1 Row at midpt 5-18, 8-13, 10-12
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3
REACTIONS. (Ib/size) 2=2451/0-8-0, 12=2341/Mechanical
Max Hom 2=170(LC 7)
Max Uplift 2=241(LC 8), 12=190(LC 8)
Max Gran, 2=2473(LC 13), 12=2350(LC 14)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 23=-4408/375, 34=-3851/387, 45=3391/381, 5-6=-4129/429, 6-8=3832/409,
8-9=2596/308, 9-10=2944/317
BOT CHORD 2-19�327/3937, 18-19=327/3937, 16-18=278/4092, 15-16=288/4157, 13-15=-245/3649,
12-13=175/2083
WEBS 3-18=599/132, 4.18=48/1223, 5-18=1104/99, 6-16=0/369, 6-15=565/90, 8-15=0/771,
8-13=1636/158, 9-13=39/925, 1(1-13=OR25, 10-12=2891/259
NOTES-
1) Unbalanced roof live loads have been Considered for this design.
2) Wind: ASCE 7-10; Vufl=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsh BCDL=6.Opsf; h=18R; B=45ft; L=47ft; eave=6ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) All plates are MT20 plates unless otherwise indicated.
5) Plates checked for a plus or minus 0 degree rotation about its center.
6) This truss has been designed for a 10.0 lost bottom chord live load nonconcument with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6.0 tall by 2-0-0 wide
will rrt between the bottom chord and any other members, with BCDL = I O.Opsf.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical Connection (by others) of truss to bearing plate capable of withstanding 100 He uplift at joint(s) except (jt=1b)
2=241,12=19D.
Thomas A. Minor! PE No.39300
MiTek l Inc. FL Cert 8634
6904 Parke East Blvd. Tampa FL 33610
Dale:
September 10,2019
®WARNING- Verlfydesignparwe,v. entl READ NOrEB ON. ANDINCLUDEOMITEK REFERENCE PAGEOP7473 rev. 10/03MISBEFORE USE.
Design valid for use onlywah MReMbaonneatom. This design is based only upon parameters shown, and is loran Individual building Component, nor
saawa
��wwee
Sal
a truss system. Before use, the building designer must ven" app6cabildy of tlesign parameters and property incogomm Nis design into me overall
buiMingtlesgn. Brscing Indicated is to prevent bucking of individual Coss web andfor ondN members only. Addidonatemporaryandpermanenibracmg
MiTek'
is alviays recollect for stability and to prevent Collapse wan possible personal injuryand pmperry, damage. Fargenerel gukance legara n Me
fabn.b.n, siorall deliveN. erection and bracing of busses and buss systems. we ANSWRI Quality Canada, DSBA9 and BCV Building Companenr
seed Parke East Blvd.
Salefylikimpodon available Bore TmssMnelnsN e.218N.Lee Sgmet,B fte312.A1exandsa,VA22314.
Tampa, FL 36610
Hip
T18074340
b
am 12
5x5 = 34 =
3as = Safi 3x8 = Safi = 3x8 =
3, 423 5 6 24 7 8 25 9
Scale=1.ao.1
Sad II
10
18 17 ,o - 11 11 1. ,. ,o 1. - - 11
2x4 11 yg = 3x8M183HS = Safi = Sas = 3x6 = Sure=
Sx6 =
3x8 M185HS =
5-]-0 11-0.0 19-11-2 2&10< 3]-9E d]-0g
Plate Offsets (X,1')-
I1:0-",0-1-12j, [3:0-2-8,0-2-0j
LOADING (psf)
SPACING. 2-0-0
CSI.
DEFL.
in (toe)
Udeft
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.85
Vert(LL)
-0.32 14-15
>999
240
MT20
244/190
TCOL 20.0
Lumber DOL 1.25
Be 0.99
Ven(CT)
-0.81 14-15
>693
180
M18SHS
244/190
BCLL 0-0 '
Rep Stress Ina YES
WB 0.99
Horz(CT)
0.22 11
n/a
We
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 257 Ib
FT=0%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.1 'Except' TOP CHORD
3-5: 2x4 SP 270OF 2.2E, 8-10: 2x4 SP No.2
BOT CHORD 2x4 SP 270OF 2.2E *Except* BOT CHORD
13-16: 2x4 SP No.1 WEBS
WEBS 2x4 SP No.3'Except'
9-11: 2x4 SP No.2
WEDGE
Left: 2x4 SP No.3
REACTIONS. Ph/size) 1=2343/03-0, 11=2343/Mechanical
Max Horz 1=210(LC 8)
Max Uplift 1=-175(LC 8), 11=202(LC 8)
Max Gmv 1=2356(LC 13), 11=2352(LC 13)
FORCES. (lb) -Mac. CompJMax.Ten. -All forces 250(lb) or less except when show.
TOP CHORD 1-2=d397/360, 2-3=-4007/366, 3-4=3555/357, 4-6=-4762/423, 6.7=4587/385,
7-9=3067/244, 10.11=252/62
BOT CHORD 1-18=-458/3884, 17-18= 458/38a4, 15-17=-447/4649, 14-15=453/4843, 12-14=-381/4164,
11-12=236/2608
WEBS 2-17=-012/116, 3-17=41/1307, 4-17=1502/116, 4-15=0/437, 6.14=533/128,
7-14=-7/800,7-12=1626/200,9.12=27/1545,9-11=-3281/299
Structural wood sheathing directly applied or 2-2-0 oc purlins,
except end verticals.
Rigid ceiling directly applied or 2-2-0 oc bracing.
1 Row at micipt 4-17, 7-12
2 Rows at 1/3 pis 9.11
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuh=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf BCDL=6.Opsf; h=18ft; B=45ft; L=47ft; eave=6ft; Cat.
II; Exp B; Encl., GCpi=0.18; M WFRS (directional); Cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) plates checked for a plus or minus 0 degree rotation about its center.
6) This truss has been designed for a 10.0 par bottom chord live load nonconcurr ant with any other live loads.
7) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except tit=lb)
1=175,11=202.
Thomas A Albani PE No.39380
MiTek USA, Inc. FL Celt 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING Venry design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGEMII-7473rev. 10/03aDI5 BEFORE USE.wasses
Designgatifar sere Mielei connectors.Thuenfit ie aplic mryv isfor
detgninto
��•
Nparemetarsaaown,antl
inintlintluatis tren4not
a a., inrnrpotem thisdesignand Intolaeoverall
martvmitygvapptitimeswbandgn parameter¢andpti.
Beforeuse,meend
��-��•YYY
d ingdslern
Bracagargircand is Ad era brazing
is to prevent bidding
bucse possiitlueltmssweaanNm dloNmemaea retry.Adainmiltetnpotaryantlra,
MiTek'
prprevent
is agngtleagn
the
with systegil injury property BNa
isaMapregorge,ded for egree lyanOtopreveM Collapse with age
SYWV1. Buggy Cravui, DSB gad
fabricaAm,. storage, Eelivery,ere Truss age ll Orgeda, OSBdB antl aCSl BUlhling Component
5a3gt see
6g04PaFL East BM1.
Tmstla oino e,21$N.Lt dN,VA 14.
SaletylNarmaflon avaJeble fmm Truss Plate Instaule.2la N. Lee $Ireet. Suie 312. Mexandru, VA 22314.
Tampa. FL 36610
Job
Truss
Truss Type
pty
Ply
Walsh Residence
T18074344
J38351
18G
Had Hip Girtler
1
ay
L
Job Reference (optional)
East Coast Truss, Ft. Pierce, FL 34W
8.240 a Jul 14 2019 MRek Industries, Inc Tue Sep 10 09:23:302019 Page 2
ID:INmub4goEcpdh37zljasEOyjN73.CXH47wDUdylrVL04sJCCKEkacPgM6gisJXOIMZW4ER
NOTES-
11) Provide mechanical Connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift atjoint(s) except 0=1b) 1=1469, 14=1821.
12) Hanger(s) or other Connection device(s) shall be provided sufficient to support Concentrated load(s) 181 lb down and 142 lb up at 7-0-0, 179 lb down and 13511D up at
9-0-12, 1791b down and 1351b up at 11-0-12, 1791b down and 1351b up at 13-0-12, 179 Ib down and 1351b up at 15-0-12, 1791b down and 1351b up at 17-0-12. 179
Ib down end 13516 up at 19-D-12, 1791b dawn and 1351b up at 21-0-12, 179 Ib down and 1351b up at 23-0-12, 179 Ib down and 1351b up at 25-0-12, 1791b down antl
135 Ill up at 27-0-12, 179 lb down and 13511b up at 29.0-12, 17916 down and 135 lb up at 31-0-12, 179 lb down and 1351b up at 33-0-12, 179 lb down and 135 Ill up at
36-0-12, 17911b dawn and 135 lb up at 37-0-12, 179 lb down and 135 lb up at 39-0-12, 179 lb down and 135 lb up at 41-0-12, and 179 lb down and 135 lb up at 43-0-12,
and 179 lb down and 135 lb up at 45-0-12 on top chord, and 137lb down and 79 Ib up at 74)-0, 98 lb down and 80 lb up at 9-0-12, 98 lb down and 80 lb up at 11-0.12.
98 Ill down and 80 Ib up at 13-D-12, 98 lb doom and 80 He up at 15-0-12, 98 Ill down and 80 He up at 17-0-12, 98 lb down and 80 lb up at 19-G-12, 98 Ib dawn and 80 lb
up at 21-0-12, 98 lb down and BO lb up at 23.0-12, 98 Ib down and 80 lb up at 25-0-12, 98 lb down and 80 lb up at 27-0-12. 98 lb dawn and 8016 up at 29-0-12, 98 Ill
down and 80 lb up at 31-0-12. 98 lb down and 801b up at 33-0-12, 98 lb down and 80 lb up at 35-0-12, 98 Ib down and 80 Ill up at 37-0-12, 98 He down and 80 He up at
39-0-12. 98 lb down and 8011D up at 41-0-12, and 98 ib down and 80 lb up at 43-0-12, and 98 Ib down and 80 He up at 454)-12 on bottom chord. The design/selection of
such Connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live balanced): Lumber Increase=1.25, Plate Incease=1.25
Uniform Loads (pit)
Vert: 1-3=80, 3-13=80, 14-26=-20
Concentrated Loads (lb)
Vert: 3=163(B) 6=163(6) 24=106(B) 5=-163(B) 21=74(B) 19=74(8) 8=163(B) 16=-74(B) 11=163(B) 10=163(B) 18=74(B) 29=163(B) 30=163(B) 32=-163(B)
33=163(B) 35=163(B) 36=163(3) 37=163(B) 38=163(B) 39=-163(8) 40=163(B) 41=163(B) 42=163(B) 43=163(8) 44=163(B) 45=74(B) 46=74(B) 47=44(li)
48=74(8) 49=74(13) 50=74(B) 51=74(B) 52=74(B) 53=74(1!1) 54=74(B) 55=74(B) 56=74(B) 57=74(B) 58=74(B) 59=74(B)
®WARNING - Vann, design parameters and READ NOTES ON THIS AND INCLUDED MREH REFERENCE PAGE M147473 rev. WgIaDIS BEFORE USE.
Design valid faruse oNywah Mnelcdlaamectala. We deep is based any Bryan Parameters ended, and is for anIMiNauel Wilding vanadium net
��®®
a Was system Before use, the buOding designer must veliythe applicabilty of deep garometers and property Nmrpoate Nis design sound owemH
�gY�
buldingdesign. Beengletieatedistopreventbclim, of lnd'Mtluel Wsaweb aMla NON memWrsany Additbnel temporary end pertnaneM bracing
MiTek'
Is always requ6ed for stability and to ine"M omapae wW possible personal injury and property damage. For general guWance regarding Me
fabrication, Storage. delivery, erection and loading ofkusses and Was 'gems. me ANSVTMI Quality Celti DS849 andBCS1 Building Component
SeAdyinfamagon awbbbfmm Tmsa PlatelnMd Umd,Sude31ZN"wdria VA22314.
6904 Pane East SIW.
.218N.Le
Tampa,F 36610
Job cuss
Truss Type
Gty
Ply
Walsh Residence
T16074345
J38351 601G
Common Girder
1
1
Job Reference (optional)
East Coast Truss, FL Pierce, FL 34946
8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Sep 10 09:23:32 2019 Page 2
ID:INmub4goEcpdh37zliasEOyjN73-9vPg0cFl8ZOZkeATzkEgPepnNDM2eng9mncNRyf4EP
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit)
Vert: 1.3=-80, 3-13=80, 13-24=-80, 24-26=80, 32-35=20
Concentrated Loads (Ib)
Vert: 3=-89(B) 27=-44(B) 31=-44(8) 29=44(B) 24=-89(B) 38=-44(B) 39=-44(B) 40=-44(B) 41=-44(B) 42=-44(B) 43=93(B) 44— 44(B) 45=44(B)
®WARNING -Venfy design ParameI. and READ NOTES ON MIS AND INCLUDED MITEK REFERENCE PAGEM0.I4I] rov. 10,034015 BEFORE USE.
Designvalk for use onryweh MnekW connectors.Tbis design is based only upon parameters WaM, and is loran lnclOdual Evllmng component net
a truss system Before use, the building designer mud veMythe appriaWle ddelp parameters and piopely incorporate this design intothe mrNl
Nil
bulldingdaslgn. BraWg(rdwed isto prevent buckling ofmdMdual MIS Web aldfaeaom members wty. AddWnaltemporaryandpermanerdbmcing
M7k'
Is always requlred for stabirly and to prevent m9apseweh possible personal iryury and property damage. Forgenerelguidanceregardilglhe
fabrication. dordge.calvary, erection and bracing oftrusses and truss8 MIS, Me ANSU IO..UWWmda,DSBd9end BCSIBu11Wng Component
e904 Padre Fast BM.
Sab"tafametfdn avagabkb Truse Pla0lnddN0.218N.Lm Sll Su4e3f2Ale dM.VA2MI4.
Tempe. FL assio
Job
Truss
Truss Type
Oty
Ply
Walsh Residence
T18074346
J38351
B02
Common
3
1
Jab Reference (optional)
East Coast Truss, Ft Pierce, FL 34946
a.00 12
4x6 =
8.240 s Jul 14 2019 MTek Industries, Inc. Tue Sep 1009:23:33 2019
Scale = 1:52 6
I6
4x8
3x4 = 44 = 3x4 — 4x6 =
=
104)-11 19-11-5 30.
10.0.11 9-10-10 I 10 11 r
Plate Offsets (X,Y)—
[2:0-0-0.0-1-0I [6:0-2-0Edoel [8:Edge 0-1-0]
LOADING (pat)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
Men
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.85
Vert(LL)
-0.41
9-11
>881
240
MT20 244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.78
Vert(CT)
-0.63
9-11
>573
180
BCLL 0.0 '
Rep Stress lncr YES
WB 0.32
Horz(CT)
0.08
8
n/a
n1a
BCDL 10.0
Code FBC2017/rP12014
Matnx-MS
Weight: 13916 FT=0
LUMBER -
TOP CHORD
2x4 SP No.1
BOT CHORD
2x4 SP No.1
WEBS
2x4 SP No.3
WEDGE
Left: 2x4 SP No.3, Right: 2x4 SP No.3
REACTIONS. (lb/size) 2=1609/0-8-0, 8=1498/0A-0
Max Hoe 2=213(LC 7)
Max Uplift 2=176(LC 8), 8=119(LC 8)
FORCES. (Ib) - Max. Comp./flax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=2587/263, 3-5=2264/301, 5-7=2273/307, 7-8=2597/269
BOT CHORD 2-11=136/2312, 9-11=0/1502, 8-9=143/2211
WEBS 5-9=70/933, 7-9=-589/210, 5.11=61/919, 3-11=582/206
BRACING -
TOP CHORD Structural "ad sheathing directly applied.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; VuH=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf BCDL=6.Opsf, h=18ft; 8=45ft; L=30ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 par bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide
will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joints) except (p=lb)
2=176,8=119.
Thomas A Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
9904 Parka East Blvd. Tampa FL 33610
Date:
September 10;2019
Job
Truss
Truss Type
Oty,
Ply
Walsh Residence
T18074347
J38351
B03G
COMMON GIRDER
1
Job Reference (optional)
Sxe M18SHS II
6.Oo 12
o.ZrVbaul 1%4U I mmI I ea lnousmes, Inc. meoep iuue:zo:eoeuie
12
Ij
1s 1a -
17
-' 16 --
15 -- -- 14
3x8 II Bx8 = HUMS
8x8 =
10x10 M18SHS =
74 = HUS26 Bab = 3x10 11 Sxio M1esms C
Sx8 M18SHS i
HUMS
THD28-2
HUMS
HUMS HUMS HUS26
HUS26 HUS26 HUS26 HUMS
31411
]-1-8 11-0.12
15-40 1 18-7-15
1 22-2-1 1 25-8-4 3660
Plate Offsets(X,Y)-
12:0.1-8,0.30] 15:D-3-00.3-4] 15:0-0-00-1-12]
(12:Edge0.2-13] 114:0.3A0.5-12] (15:0-3-00-4-12] ry6:0S-00-6-0) (17:0.3-80-5-8] (18:D-3-80.6-0]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(too)
Vdeft
L/d
PLATES
GRIP
TCLL 20.0
Plate Gnp DOL 1.25
TC 0.91
Vert(LL)
0.26
17
,999
240
MT20
244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.87
Vert(CT)
-0.62
15
>584
180
M18SHS
244/190
BCLL 0.0 '
Rep Stress Ina NO
WB 0.94
Horz(CT)
0.16
12
Na
n/a
BCDL 10.0
Code FBC2017rTP12014
Matrix -MS
Weight: 691 lb
FT=O%
LUMBER. BRACING -
TOP CHORD 20 SP 270OF 2.2E *Except* TOP CHORD Stmctuml wood sheathing directly applied or 3-4-5 oc purring.
7-9: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 10-M Be bracing.
BOT CHORD 2x8 SP SS
WEBS 2x4 SP No.3 *Except*
7-16; 2x4 SP No.1, 6A7,8-15: 2x4 SP No.2
REACTIONS. (Ib/size) 2=1469910-8-0, 12=18917/0.8-0
Max Holz 2=213(LC 7)
Max Uplift 2=2406(LC 8), 12=1984(1_C 8)
FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-29588/4809, 3-4=J7100/5060, 4-6=26241/3658, 6-7=-21222/2743,
7-8=21215/2743, 8-10= 25839/3089, 10.11=30702/3475, 11-12=34129/3696
BOT CHORD 2-19=-4235/26345, 18-19=4235/26345, 17-18=-4416/27816, 16-17=3086/23409,
15-16=-2566/23040, 14-15=2984/27452, 13-14=3244/30450, 12-13=-3244/3D450
WEBS 7-16=-2351/18479,4-lB=1770/5852, 3-19=-1626/248,3-18=425/1826,4-17=-5994/1809,
6-17=1601/8345, 6-16=7735/1550, 11-13=-238/3296, 11-14=3568/307,
10.14=563/6796, 10.15�6665/631, 8-15=679/8274, 8-16=7587/693
NOTES.
1) Special connection required to distribute bottom chord loads equally between all plies.
2) 3-ply truss to be connected together with 10d (0.131"x3') nails as follows:
Top chords connected as follows: 2x4 -1 row at 0-4-0 oc.
Bottom chords connected as follows: 2x8 - 4 rows staggered at 0-4-0 oc.
Webs Connected as follows: 2x4 - 1 now a10.9-0 Do. '
3) All loads are Considered equally applied to all plies, except If noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply Connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
4) Unbalanced roof live loads have been Considered for this design.
5) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf; BCDL=6.Opsf; h=1Bit; B=45ft; L=3011; eave=oft; Cat. "
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
6) All plates are MT20 plates unless otherwise indicated.
7) Plates checked for a plus or minus 0 degree rotation about its center.
8) This truss has been designed for a 10.0 psf bottom chord live load noncancunent wgh any other live loads.
9) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 1001b uplift at joint(s) except Ut=lb)
Thomas A. Atbani PE 1,109388
2=2406, 12=1984.
MIT& USA, Inc. FL Cert6634
11) Use USP THD28-2 (With 28-16d nails into Girder & 16A Od nails into Truss) or equivalent at 7-1-11 from the left end to Connect
6904 Parke East Blvd. Tampa FL 33610
truss(es) to front face of bottom chord.
Data:
12) Use USP HUS26 (With 14-16d nails into Girder & &I6d nails into Truss) or equivalent spaced at 2-0-0 oc max. starting at 9-G-12
September 10,2019
nflacendthis to 29-0-12 to Connect truss es to front face of bottom chord.
®WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEN REFERENCE PAGE 14II-7473 rev. 10/03rz015 BEFORE USE.
Design valid for use any wM MReM connectors. This design is based only upon pammmers shown, and is for an IlmMdual bugding mmponem net
��•
a truss system. Before use, the bwlding designer must writ' Use applicability of design pammetem and property incorporate and design into Me overall
bulldiagdeslgn. Brangindir distopmwnlbucmgdMdMdualtmsswebanww WoMmem mmy.Add'Eional temporary antl pemuneM Mating
M!Tek'
IsaMaysrequimdbrdabifdyandtopre MwUapsewtlhpo blepersaulinju mdpmpellydamage. ForgenemIgukanceregartling Ne
fabdmuon,storege,delivery,erecgonmdbmdMWtmswsaMnssggems,see ANSUTP/l oueliry Cdreda, 0.SBA8antl BCSl Bulleing Component
Saga Parke East BIM.
Sarey3nremu Nor, av tbk frwn Truss Rate ineatme, 21$ N. Lee Street Sub.31Z Alexandria, VAM314.
Tampa, FL 36510
Job
Truss
Truss Type
Cry
Ply
Walsh Residence
T18074347
138351
B03G
COMMON GIRDER
1
q
J
Jab Reference (optional)
casr lioaal t russ, n. rierce, r�,la:wb n.240 S Jul 1421119 MITek Industries, Inn Tue Sep 10 09:23:35 2019 Page
NOTES-
ID:INmu64goEcpdh37zijasEOyjN73-ZU4z2eHdRUOBb u2esoNl HRHfQJBn4fbSo5Hzmyf4EM
13) Fill all nail holes where hanger is in Contact with lumber.
LOAD CASE(S) Standard
1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Unddnn Loads (plf)
Vert: 1-7=-80, 7-12=80, 20-23=20
Concentrated Loads (lb)
Vert : 16=2323(F) 18=4959(F) 17=2323(F) 25=2323(F) 26=2323(F) 27=2323(F) 28=2323(F) 29=2323(F) 30=2323(F) 31=2323(F) 32=2323(F) 33=2323(1`)
®WARNING- Vestry design parameters andREAO NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 ree. 10/03420I5 BEFORE USE
valid for use only with MTek® cargesoors. This design is based only upon pa2metem shown, and Is far an indwidual building component not
Val'Design
a Miss system. Before use, the building designer must verifythe applicability of desgo parameters and properly In supmede Nos design into Me overall
building design: Bracing indicated is to prevent buckling of individual Miss web anmm cJhortl members only. additional temporary and permanent bract,,
MiTek'
is allays required for stabiBy and to prevent collapse with Possible personal injury, and property damage. Forgenemlgukanceregardirgthe
(admiration. storage, delivery. erection and braving of misses and Miss "area,see ANSTPll Duality(riroda, DuBs and BCSI BuIlding Component
6804 Parke East BNd.
Sarelylnformafion available from Truss Plate Inatilme.218 N. Lea Sbeet. Sufte 312, Mmndda. VAM14.
Tampa, FL 36810
Job
rues
Truss Type
Oty
Ply
Walsh Residence
TtBW4348
J38351
C01G
Common Girder
1
7
Job Rc(nr n inn ell
Cast Boast bliss, YL Pierce, t-L 64e4b
=
TOP CHORD MUST BE BRACED END JACKS, 4x4
ROOF DIAPHRAGM, OR PROPERLY CONNECTED
8.240 s Jul 14 2019 MTek Industries, Inc. Tue Sep 10 09:23:37 2019
Scale=132.7
15
3.4 = 1x4 II 3x8 = 1x4 II 3x4 =
3-V13 84-0 I 1433 17.40 i
3 c.13 utO
Plate Offsets (X,Y)-
[2:Edge 0-0-12j [3:0-4-1 0-1-15) [14:0-0-1 0-1-15) ry5:o-0-00-0-121
LOADING (psf)
SPACING- 2-0-0
-CSI.
DEFL.
in (roc)
Udeff
L/d
PLATES GRIP
TOLL 20.0
Plate GOP DOL 1.25
TO 0.42
Vert(-L)
-0.04 17-18
>999
240
MT20 2441190
TOOL 20.0
Lumber DOL 1.25
SC 0.75
Vert(CT)
-0.1217-18
>999
180
BCLL '0.0 '
Rep Stress Ina NO
WB 0.22
Horz(CT)
0.04 15
Na
n/a
BCDL 10.0
Code FBC2017/fP12014
Matrix -MS
Weight: 1071b FT=0
LUMBER.
TOP CHORD 2x4 SP No.2
BOTCHORD 2x4SPNo.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD Structural wood sheathing directly applied a4-2-9 oc puffins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
JOINTS 1 Brace at Ala): 9, 7, 11
REACTIONS. (lb/size) 15=989/0-8-0, 2=1104/0.8-0
Max Hoe 2=123(LC 7)
Max Uplift 15=-129(LC8), 2=187(LC 8)
FORCES. (III) - Max. CompJMax. Ten. -,All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=1676/222, 3d=1034/113, 4-6=1001/136, 6.8=979/173, 8-10=980/173,
10-12=1001/136, 12-14=-1035/114, 14-15=-1708/240,3-5=321/43,5-7=325/45,
7-9=325/45, 9-11=325/45, 11-13=325/45, 13-14=320/43
BOT CHORD 2-18=154/1464, 17-18=156/1450, 16-17=174/1452, 15-16=173/1465
WEBS 8-9=75/588, 9-17=0/413, 3-17=295/108, 14-17=317/126
NOTES-
1) Unbalanced roof live loads have been cansidered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=I24mph; TCDL=9.Opsf, BCDL=6.Opsf; h=188; B=45tt; L=24tt; eave=oft; Cat.
II; Exp B: Encl.. GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 pat bottom chord live load nonconcument with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except gt=lb)
15=129, 2=187.
8) Graphical puffin representation does not depict the sae or the orientation of the purlin along the top and/or bottom chord.
9) Hanger(s) or other Connection device(s) shall be provided sufficient to support Concentrated load(s) 87lb down and 64 lb up at
3-3-9, and 871IS down and 64 Ib up at 14-0-7 on top chord, and 106lb down and 70 Ib up at 3-0-0. 21 Ib down at 5-0-12, 21 Ib
down at 7-0-12, 21 Ib down at 8-8-0, 21 It, down at 10-3-4, and 2111, down at 12-3-4. and 106 Ib down and 70 lb up at 14-3-4 on
bottom chord. The design/selection of such Connection device(s) is the responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate lnaease=1.25
Uniform Loads (p*
Vert: 1-3=80, 3-8=80, 8-14=80, 14-15=80, 19-22=mW
Concentrated Loads (lb)
Vert: 18=89(F) 16=89(F) 17=10(F) 3=12(F) 14=12(F) 25-1 O(F) 26=10(F) 27=10(F) 28=10(F)
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert6034
6904 Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
® WARNING -Wlily tlesign parameter and READ NOTES ON INS AND INCLUDED MITEK REFERENCE PAGE MII.7473 iev. 10N3a0ls BEFORE USE.
Design valid (muse oM7wan MRea® olnncoms. Thus design is based only upon parameters sbovn, and Is for an Indiddual building component. not
��®®
a truss%Wem Beforuse, me buiding desgner must verity the appliuMily of design parameter and properly mooryorale this design olia Me Overall
�<Y�•
builtlingdesign. Bracing lndicaled is to proved barking of Individual truss web anther ChiN member only. AiRldeotemporyand petmanenlbmcang
MiTek'
is always required for stabiNy and to prevent co9apse wed possible personal inluyand propeM damage. Forgeneral guidance regarding the
fabdrabon, alorge. deUmq. meall and leasing etUusses am Wes systems.see ANSU7PIt quality Creeds, DS849 and BCS1 Building Component
6901 Parke East DIAL
Selorylnformation available fin. Truss Plate lnW Wu , 218 N. Lee Street. Suil.312. Alexandra. VA22314.
Tampa, FL Sal
Job
loss
Truss Type
Oty
Ply
Walsh Residence
T18074349
J38351
CO2G
Common Girder
1
Job Reference (optional)
I was, M. elerce, 1-1-44 b 8.240 s Jul 142019 MiTek industries, Inc. Tue Sep 1009:23:382019
3
Seale-137.6
4x8MI6SHS II
44 MISSHS = us II Bx8 = 10x10 = 8x8 M = Bx8 = HUS26 3.8 II HUS26
5x8 M18SHS
4x8 II THDH28-3 HUS26 HUS26
3
3H8A I 19A11 174-0
1 3d7
le
Plate Oftsets(X,Y)—
[2:0.0-120-0-51 [2:0-1-01-0-31 [9:0-5-120-1-0[
[110:0-3-80-6-0I
[72:0-5-00.6.4) (13:0.3-80-6-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
yde5
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.85
Ved(LL)
0.16
13
>999
240
MT20
2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.67
Vert(CT)
-0.31
13
>668
180
M18SHS
2441190
BCLL 0.0
Rep Stress Ina NO
WB 0.81
Horz(CT)
0.06
8
me
n1a
BCDL 10.0
Code FBC2017/rP12014
Mamx-MS
Weight: 2511b
FT=0
LUMBER -
TOP CHORD
2x4 SP No.2 *Except'
5-8: 2x4 SP No.t
BOTCHORD
2x8 SP DES
WEBS
2x4 SP No.3 *Except'
5-12: 2x4 SP No.11
OTHERS
2x4 SP No.3
WEDGE
Left: 2x4 SP No.3
REACTIONS. (Ib/size) 8=9381/0-8-0, 2=6748/0.8-0
Max Horz 2=123(LC 24)
Max Uplift 8=1396(LC 8), 2=1472(LC 8)
BRACING -
TOP CHORD Structural Wood sheathing directly applied or 2-2-8 oc purlins.
BOTCHORD Rigid ceiling directly applied or 10-0-0oc bracing.
FORCES. (lb) -,Max. Comp./Max. Ten. -All forces 250(I1a) or less except when shown.
TOP CHORD 2-9=-13277/2900, 33=13286/2914, 4-5=12008/2455, 5-6=12070/2457,
6-7=-15122/2600, 7-8=-17305/2687
BOTCHORD 2-14=2532111819, 13-14=2532/11819, 12-13=2489/11830, 10-12=2230/13503,
9-10=2352/15419, 8.9=2352/15419
WEBS 5-12=2099/10330, 4-12=2662/1106, 4-13=1213/3005, 3-13=298/264, 6-12=4072260,
6-10=219/4246, 7-10=-2332/148, 7-9=98/2160
NOTES-
1) 2-ply truss to be connected together with 10d (0,131"x3") nails as follows:
Top chords connected as follows: 2x4 -1 raw at 0-7-0 oc.
Bottom chords connected as follows: 2z8 - 2 rows staggered at 0.2-0 oc.
Webs connected as follows: 2x4- 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except R noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise Indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vuh=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; B=45ft; L=24ft; eave=4ft; Cat.
11; Exp B; Encl., GCpl=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
5) All plates are MT20 plates unless otherwise indicated.
6) Plates checked for a plus or minus 0 degree rotation about its center.
7) This truss has been designed for a 10.0 per bottom chord live load nacc ncurrent with any other live loads.
8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will rn between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except 0=11b)
8=1396,2=1472.
10) Use USP THDH28-2 (With 36-16d nails into Girder 810-16d nails into Truss) or equivalent at 7-1-11 from the left end to connect
truss(es) to back face of bottom chord.
rev. le/ M015 BEFORE USE.
:ammo mmvanent not
s prevent buckling of IndMdual Imss web anWar moral members
revem.11apso won possible personal iNuryaM pmpmy curve
and bradna of trusses and truss systems. see AM IM
Thomas A. Alban PE No.39380
MiTsk USA, Ine. FL Colt6634
9904 Parke East Blvd. Tampa FL 33610
[late.
September 10,2019
r1�alY�
Mirek'
Job rasa
Truss Type
Oty
Ply
Walsh Residence
T78074349
J38351 CO2G
Common Girder
1
Jab Reference (optional)
truss, FL Pierce, P L J4945
8,240 s Jul 14 2019 MITek Industries, Inc. Tue Sep 10 09:23:38 2019 Page 2
NOTES- ID:INmub4goEcpdh37zliasEOyiN73-z3m6g0(WkPmiSZddK?L4eyWtdNy_TO28mKza5yf4EJ
11) Use USP HUS26 (Wdh 14-16d nails into Girder & 6-16d nails into Truss) or equivalent spaced at 2-0-0 oc max. starting at 9-0-12 from the left end to 15-012 to connect
truss(es) to back face of bottom chord.
12) Fill all nail holes where hanger is In contact with lumber.
LOAD CASE(S) Standard
1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Ungorm Loads PI)
Vert: 1-5=80, 5-8=80, 15-18=-20
Concentrated Loads (III)
Vert: 13=5004(B) 21=2321(B) 22=2321(B) 23=2321(B) 24=2321(B)
®WARNING-Vady design parameters and READ NOTES ON THIS AND INCLUDED MJTEKREFERENCEPAGEM6703rs✓ 1"320f59EFOREUSE.
Design valid for use onywhh MReL®Wmtttps. Title design is based arty upon parameters shown, am! Is In an IrMMdual bugdmg component, got
�*B
a Wu system. BMore use, are building designer must witty are epptirabitiy Odesign parameters and pmpert Nmmoreta We dealpIto the ienall
-lY�
bWldmgdeslgn. Bmci giNi ediSlopmwniNu gdMdMdualUuuwebanOwWoMmembemmn,. AddNWnaltemporayendpe membracing
MiTek'
Is always required for stabildy and to prevem collapse with possible personal injury and property damage. Forgenemlguldancaregavingtha
fab@atlon, storage. delivery. erection and bracing nttmssas and Was systems, us ANSUTPH ORaI/ty Ciffinde, DSad9 aid Seat Building Component
6904 sense East Bhd.
Soraylnromletlon available Bom Tmu Mate In9ftO., 218 N. Lee Street, &fte 312, Alexandria, VA22314.
Tampa. FL assio
Job
Truss
Tuss Type
Oty
Ply
Walsh Residence
T78074350
J38351
D01G
Hal/Hip Giber
1
q
Job Reference(optional)
cab! CUaa! Duab, rt. ri nue, rL avano
5x8M18SHS i
HUS28
Jul 14 2019 MiTek Industries, Inc, Tue Sep 10 09:23:392019
Tx8 = 1.4 II Bids = Scale a 129.8
3 13
HUS26
VF HUS26 u Sx8 =
43 I436 10s I I&-1-51 I 13b11 5
Plate Offsets(X,V)—
f1:Edge0-3-01[3:0-6-00-2-81 (5:0.2-40-2-0)
[6:Edce0.2.8] 17:0-5-00-5-12]
[8:0-3-80-6-41 [9'0.6-00-1-81
LOADING (pet)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
Vde0
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.87
Vert(LL)
-0.10
8-9
,999
240
MT20
2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.70
Vert(CT)
-0.24
8-9
>749
180
M18SHS
2441190
SCLL 0.0 '
Rep Stress Ina NO
Wit 0.82
Horz(CT)
0.D4
6
n/a
n/a
BCDL 10.0
Code FBC20171TPI2014
Matrix -MS
Weight: 237111
FT=0%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
BOT CHORD 2x8 SP SS
WEBS 2x4 SP No.3'Except' BOT CHORD
5-6: 2x8 SP No.2, 3-8,4-7: 2x4 SP No.2, 5-7: 2x4 SP No.t
REACTIONS. (Ib/sjze) 1=7814/D-8-0, 6=9668/0.8-0
Max Horz 1=160(LC 25)
Max Uplift 1=657(LC 8), 6=868(LC 5)
FORCES. (lb) - Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=14156/1210, 23=-9100/803, 3-4=5598/504, 4-5=5598/504, 5-6=7487/693
BOT CHORD 1-9=-1184/12615, 8-9=-1184J12615, 73=760/8324
WEBS 2-9=328/4308, 2-8=5106/500, 3-8=595/7094, 3-7=-4328/407, 4-7=-256/152,
5-7=-819/91l l
Structural wood sheathing directly applied art-4-4 Do purling,
except end vergcals.
Rigid ceiling direWy applied or 10." oc bracing.
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 -1 row at 0-7-0 oc, 2x8 - 2 Tows staggered at 0-9-0 Go.
Bottom chords connected as follows: 2x8 - 2 Tows staggered at 0.5-0 Be.
Webs connected as follows: 20 - 1 row at 0.9-0 Do.
2) All loads are considered equally applied to all plies, except If noted as from (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to dishlbute only loads noted as (F) or (B), unless otherwise Indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=160mph (3-secand gust) Vasd=124mph; TCDL=9.OpsY BCDL=6.0TSY h=18ft; B=45ft; L=24ft; eave=oft; Cat.
II; Exp B; End., GCpi=0.18; MWFRS (directional): cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
5) Provide adequate drainage to prevent water ponding.
6) All plates are MT20 plates unless otherwise indicated.
7) Plates checked for a plus or minus 0 degree rotation about its center.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0tall by 2-0-0 wide
will fit between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Gt=lb)
1=657,6=868.
11) Use USP HUS26 (With 14-16d nails into Girder & 6-16d nails into Truss) or equivalent Spaced at 2-0-0 oc max. starting at 2-4-12
from the left end to 14-4-12 to conned truss(es) to front face of bottom chord.
12) Fill all nail hales where hanger is in contact with lumber.
LOAD CASE(S) Standard
Thomas A Albani PE No.39380
MiTek USA, Inc. FL Cad 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
September 10,2019
®WARNING- Vedly4esign parsmelem anJREAD NOTES ON TMS AND INCLUOEDMITEK REFERENCE PAGE Ml1-MTIMv. r&MOIS BEFORE USE.
Design valid fpruse onywhb 34Tek®connectan. The design Is based any upon pa imetem shown, and is for an IMiMusl budding component nth
a miss spine. Before use, the bidding designer must verythe applicaoWN of des, parameters and properly hcory4mte We design Into Me ..a
budUingdesgn. BMCMgindic dlslopmmtWWG g&Od'Mdual WaswebaMWUOMmembeMwn,. Addnknel temporary arq permanem brecmg
MiTek'
Is etways required forslabifiyand to prevent Collapse wim possible personal injury and pmpedy damage. For gener0 guWarxa reg th gardke
fabrication. storage. deevery. erection and blaring ofWsses and Buss systems,see ANSYTIM Quern Cdede, MB49 and SCSI Building Component
6904 Parke East BM.
Sahylnfsarefldn avnadefrom Tresspieta Inst8Ne.318N.Lee6 d.gone312.Ab dra,VA22314.
Tampa. FL 36610
Job
toss
Tluss Type
Oty
Ply
Walsh Residences
T18074350
J38357
DO1G
Half Hip Girder
1
L
Job ReferReference(optional)
East Coast mass, FL Fierce, FL 3d945
8 240 s Jul 14 2019 MTek Industries, Inc. Tue Sep 10 09:23:39 2019 Page 2
ID:INmub4goEepdh37zljasECyjN73-RGKUu?KBV ua4jCptisJB7¢LljjjwUBND3U6Xyf4El
LOAD CASE(S) Standard
1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pIQ
Vert: 1-3=80, 3-5=80, 6-10=20
Concentrated Loads (lb)
Vert 9=-2292(F) 8=2292(F) 14=2285(F) 15=2292(F) 16=2285(F) 17=2247(F) 18=2286(F)
®WARNING-Verify0esign parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGEMlld473 rev, 10,03aOIS BEFORE USE.
•
Design vaid for use only wan Miness, connecoms. This design is based only upon parameters shown, and is for an IndiNdval hurting comparison, not
a Mass spasm. Before use, the bonding designer must veuythe approrblMy of deep Parameters and properly Incorporate this design into Me mane;
building design. Stating Udicated is to prevent buriling of mtliNdual buss web aMlor Uroin members only. Andilunal temporary and permanent bradng
M!Tek'
is always required for stability andto prevent calapse want possible personal inluryand property damage. Forgeneml guidance regaining Ne
fabrication, storege,degvey,eredion and bade, Whoever; and Voss System;see ANSIVIFol Quality Creeds, DS"9 and=1 Building Component
6904 Pare East BIM.
Sarefylnformatlon availabb hmn Truss Plate insl4ute, 218 N.Lee Slreel, Sude 312, Plexantlru, VA Ttd1d.
Tampa, FL 26610
Job
Truss
Truss Type
0ty
Ply
Walsh Residence
T18074352
J38a51
E01
Common
1
1
Job Reference (optimal)
East Coast Truss, Ft. Pierce, FL 34946
3x4 =
4r6 =
4x4 =
8.240 s Jul 14 2019 MTek Industnes, Inc Tue Sep 10 09:23:41 2019
3x4 =
3.4
Scale = 1:51.5
Ia
4x6 =
Plate Offsets (X Y)—
rl:0-0-0 0-1-01 (S:Edae 0-1-41
LOADING (pst)
SPACING- 2-"
CS].
DEFL.
in
(loc)
Vdefl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.98
Vert(ILL)
-0.38
6-8
-913
240
MT20 2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.97
Vert(CT)
-0.59
6-8
>578
180
BCLL 0.0 '
Rep Stress Inv YES
WB 0.58
HorZ(CT)
0.08
5
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 130 lb FT=0%
LUMBER -
TOP CHORD
2x4 SP No.2
BOT CHORD
2x4 SP No.2
WEBS
2x4 SP No.3
WEDGE
Left: 2x4 SP No.3, Right: 2x4 SP No.3
REACTIONS. (lb/SIZe) 1=143310.8-0, 5=1433/0-8-0
Max Hom 1=188(LC6)
Max Uplift 1=-508(LC 8), 5=508(LC 8)
FORCES. (Ib)-Max.Comp./Max. Ten. -All forces 250(lb) or less except when shown.
TOP CHORD 1.2=-2479/866, 2-3=2171/901, 3-0=2171/901, 4-5=-2479/866
BOT CHORD 1-8=-685/2110, 6-8=362/1404, 5-6=685/2110
WEBS 3.6=-0891799, 4-6=559/210, 3-8=389/799, 2-8=559/210
BRACING.
TOP CHORD Structural wood sheathing directly applied.
BOTCHORD Rigid Ceiling directly applied or 2-2-0 Go bracing.
NOTES-
1) Unbalanced roof live loads have been Considered for this design.
2) Wind: ASCE 7-10; Vutt=160mph (3-second gust) Vasd=124ni TCDL=9.Opsh BCDL=6.OpsY h=18ft; B=45ft; L=290; eave=oft; Cat.
11; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.60
plate grip DOL-1.60
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom chord live load noncencument with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf an the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL= %Opsf.
6) Provide mechanical Connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
1=508,5=508.
Thomas A Alban! PE No.39380
MTek USA, Inc. FL Cart 6634
69U Parke East Blvd. Tampa FL 33610
Dater -
September 10,2019
®WARNING - Verify design F.Inwwn and READ NOTES ON THIS AND INCLUDED MTEK REFERENCE PAGE MIT 7473 re¢ 1"12015 BEFORE USE.
Desgn vaid tar use only wan INTek®connepon. This Gauge is based only upon parameters shown, and Is far an IadiNdual Wad" companem, not
a Wu System. Before use, the bwlding designer mug very me applicability of deslgl parameters and Maidenly Hocn,vere MIS design into Me overall
buildingdeslgn. BracNg Ndi:aled is to buckling of NQMdual MISS web adoor Nod members Rey. ADdNanal lampoery elM permanent treeing
MTek'
prevent
Is always re9uSad for siabgdy, and to prevent=11apsewdh possible personal lnjuryand papedy damage. Forgenemlgubanceregadingthe
fabrication, starege, Uegvery,erection and Seeing utbuseesa,d Uuss systems, see ANSVTPf1 Quality Cdada, DSB49 and SCSI Duild(ng Compound!
6904 Parke East Blvd.
Sererylnformagon avagable font Tass Rma Ingd0o, 216 N. Lee &MM. SUGB 31Z Alexendda, VA23314.
Tampa, FL 36010
Job Truss
Truss Type
Dry
Ply
Walsh Residence
T18074353
J38351 E02
Hip
1
1
Job Reference (optional)
Truss, FL I'leme, bL 34a46
4xe =
4x4 =
8.240 s Jul 14 2019 MiTek Industries. Inc. Tue
Scale=149.3
4x8
1x4 II Sea = 3.8 = 3x4 = 1x4 II Axe =
6-]-0 13-0-0 1543-0 22-1-0 2&&0
1 bT-0 f _ a.zn — I
Plate Offsets (X,Y)—
[2:0-0-0,0-1-0I [4:0-54 0-2-0[ [7:0-0-0 0-1-01
LOADING (pat) ,
SPACING. 2-0-0
CST.
DEPL,
in (loc)
Udell
Ud
PLATES
GRIP
TOLL 20.0
Plate Grip DOL 1.25
TC 0.71
Vert(LL)
0.20 11-12
>999
240
MT20
2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.76
Vert(CT)
-0.2711-12
>999
180
BCLL 0.0 -
Rep Stress Inv YES
WB 0.77
Hom(CT)
0.09 7
his
n1a
BCDL 10.0
Code FBC20177TPI2014
Matrix -MS
Weight: 154111
FT=0%
LUMBER.
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3, Right: 2x4 SP No.3
REACTIONS. (lb/size) 7=1431/0-8-0, 2=1542/0.8-0
Max Holz 2=185(LC 7)
Max Uplift 7=506(LC 8), 2=563(LC 8)
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puffins.
BOTCHORD Rigid ceiling directly applied or 6-10-14 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250(lb) or less except when shown.
TOP CHORD 2-3=2507/889, 3<=1830f7O9, 4.5=15331673. 5-6=1832f7lO, 6-7=2522/898
BOT CHORD 2-12=708/2136, 11-12=708/2136, 10.11=-024/1531, 8-10=-717/2152, 7-8=717/2152
WEBS 3-11=711/328, 4.11=222/439, 5-10=225/443, 6-10=728/337, 6.8=-104/252
NOTES-
1) Unbalanced roof live loads have been Considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124ni TCDL=9.Opsf, BCDL=6.Ops/; h-18ft; B=45ft; L=29ft; eave=oft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.60
plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 36-0 tall by 24)-0 wide
Will rd between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except Qt=lb)
7-506,2=563.
Thomas A Albani PE No.39300
M1Tek USA Inc. FL Cert6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING-Veriry design parameters and READ NOMS ON THIS AND INCLUDED MITEK REFERENCE PAGE MIF7473 ew.10/0=015 BEFORE USE.
Design valid Sir use onywM Mffek® Damocles. This cargo Is based only upon pa2metem shown, and Is foran IndiaWual building romponem no
a Was system. Before use, me buipmg designer must wily the appgDeNly of design parameters and pmpedy NDomorate this deep she in. overall
sonredesign.. Bracing in late prevent burJding of individual Was web sndlmchord members only. AddNenaltemporeryandpeimea.mbroong
MiTek'
Is abvays second for stability and to prevem coaapse wily, possible personal Injury and property damage. Forgeneralguldanceregardingthe
fabduffon,storage,deWery,emWonadbmdngol WfsesaMWsfsystems,we ANSU lDualiy CModa, DS849 and BCSI Building Component
6901 Parke Esat Blvd.
Saforylnlarmodon a flabkram TwoPlopinsMO0,219N.Leaatree4SuU312.Alexandria,VA22314.
Tampa, 11 36510
Job
Truss
Type
01y
Ply
Walsh Residence
T78074354
J38351
E03
Hip
Pip
1
i
Jab Reference (optional)
N r,. rrc , re.ws4o
4x0 =
19
e.24U S JUI l4 2Ule MI I eK InGuSMOS, MC. 1 u8 bep lU UB:23432019
4x5 =
Scale =1:49.3
lz 11 lU C
Axe = 1x4 It 3x4 = 3x8 = U4 = tx4 I axe =
5-7-0 11-0-0 1T-8-0 z8-1-0 z6--0
ST.rI LLI1
Plate Offsets (X,Y)—
12:0-0-0 0-1-0] [4:0-5-40-2-0I [7:0-60 0-1-4]
LOADING (psQ
SPACING- 2-0-0,
CSI.
DEFL.
in (IDc)
Ydee
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.74
Vert(LL)
0.17 10-11
>999
240
MT20 2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.82
Vert(CT)
-0.2411-12
>999
180
BCLL 0.0
Rep Stress Ina YES
WB 0.41
Horz(CT)
0.10 7
n/a
n/a
BCDL 10.0
Code FBC2017rrP12014
Metri%-MS
Weight: 1481b FT=O%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 *Except' TOP CHORD
4-5: 2x4 SP No.1 BOT CHORD
BOTCHORD 2x4SPNo.2 WEBS
WEBS 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3, Right: 2x4 SP No.3
REACTIONS. (Ib/size) 7=1431/0-8-0, 2=1542/0-8-0
Max Horz 2=159(LC 7)
Max Uplift 7=506(LC 8), 2=563(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250(lb) or less except when shown.
TOP CHORD 2.3=2523/893, 3-4=20187768, 4.5=173Of724, 56=2022/769, 6.7=-2543/904
BOT CHORD 2-12=722/2158, 11-12=722/2158, 10-11=512/1727, 8-10=733/2178, 7-8=733/2178
WEBS 3-11=512/244, 4-11--215/446, 5-10=218/449, 6-10=532/256
Structural wood sheathing directly applied or 2-11-10 oc punins.
Rigid ceiling directly applied orb-104 oc bracing.
1 Row at midpt 4-10
NOTES-
1) Unbalanced roof live loads have been Considered for this design.
2) Wind: ASCE 7-10: Vuft=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf; BCDL=6.Opsf h=18ft; B=45ft; L=2911; eave=oft; Cat.
II; Exp B; Encl., GCpl=0.18; MWFRS (directional); Cantilever left and right exposed; porch left and right exposed; Lumber DOL-1.60
plate grip DOL=1.60
3) Provide adequate drainage to prevent water pounding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed fora 10,0 par bottom chord live load nonconcurrent with any other live loads.
6)' This buss has been designed for a live load of 20.Opsf on the bottom chard in all areas where a rectangle 3.6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) except 0=11b)
7=506, 2=563.
Thomas A. Albani PE N4.79380
MiTek USA, Inc. FL Cent 6034
6904 Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING. Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE FACE MI474TJ rev, IG/OM015 BEFORE USE.
seress
DesgnvalM for use onlywM MTeMMnnWOM, This design is based"upon pa tiers Shbxn, and iSlm M jMivdue Welling compomnL not
��®®
131,
a buss System. Before use, the bull"g, designer must very Ore applica l0y of design parameters and properly hwryordte Ws design into Me overall
bunfingdoegn. BrachghgkatedistopmvenlWTFJingelh6vidualimsswebanvarNabmemberonq AddAiOnaltemporer,ampermanentbrachg
MiTek'
b always reguimd for Noting and to prevent collapse wM posecTe personal injury and prapeM damage. For general luggage regarding the
fabdntion,storage. de6vety, erection and begging 0 agues wM truss Systems,see ANSVI111 Duality Creeds. DSB49 and SCSI Building Component
Sefetyleforeneon avagabkbmn Tmss Rl elnMW e,218N.LeoS O.Sute312NexandM.VA22314.
6901 Parka East am.
Tampa, FL 36610
Job
Truss
Truss Type
any
Ply
Walsh Residence
T18074355
J38351
E04
Hip
7
1
Job Reference (optional)
east Goast l was, YC Piston, tL 44"t, 8.240 5 Jul 14 2019 MI l ek lnauSVlea, MC,
48 =
1.4 II Asa =
4 19 5 20 6
09:23:442019 Pagel
Scale=150.3
lL ll Y
44
3x4 = W = 3x4 = 3x4 = 44 =
0.0.0 I 14-0-0 I 1&&0 I 2&8-0 r
Plate Offsets (X,Y)-
12:Edge,0.14I (4:05-4,0-2-0) 16:0.5-0
0.2-0)
8:0.0.0 0-1-0)
LOADING (pat)
SPACING- 2-0.0
CSI.
DEFL.
in
(loc)
8de0
Ltd
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.59
Ven(LL)
0.23
9-15
>999
240
MT20
2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.95
Vert(CT)
-0.32
9-15
>999
180
BCLL 0.0
Rep Stress Ina YES
WB 0.22
Horz(CT)
0,10
8
n/a
n/a
BCDL 10.0
Code FSC2017/TPl2014
Matrix -MS
Weight: 147 de
FT=0%
LUMBER. BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
BOTCHORD 2x4SPN0.2 BOTCHORD
WEBS 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3, Right: 2x4 SP No.3
REACTIONS. (lb/size) 8=1431/0.8-0, 2=1542/0-8-0
Max Harz 2=132(LC 7)
Max Uplift 8=-506(LC 8), 2=-563(LC 8)
FORCES. (M) - Max. CompJMax. Ten. -All forces 250 (M) or less except when she".
TOP CHORD 2-3=2535/873, 3-4=-2187/824, 45=2210/866, 5-6=2210/866, 6-7=2195/829,
7-8=2554/883
BOTCHORD 2-12=-720/2179, 11-12=596/1891, 9.11=-600/1898, 8-9=732/2201
WEBS 3-12=-342/145,4-12=-182/392,4-11=131/514,5-11-479/116,6-11=139/508,
6-9=189/399, 7-9=3591155
Structural wood sheathing directly applied or 3-1-4 oc putting.
Rigid Calling directly applied or 2-2-0 oo bracing.
NOTES -
I) Unbalanced mot live loads have been Considered for this design.
2) Wind: ASCE 7-10: Vuft=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf, BCDL=6.Opsf; h=18ft; B=45ft; L=298; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.60
plate grip DOL-1,60
3) Provide adequate drainage to prevent water pending.
4) Plates checked for a plus or minus 0 degree notation about its center.
5) This truss has been designed for a 10.0 psf bottom chard live load nonconcu ent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom Chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide
will fa between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 1001b uplift atjoint(s) except Ot=lb)
8=506,2=563.
Thomas A. Albert PE No.39380
MITek USA, Inc. FL C&A6634
6904 Parke East Blvd. Tampa FL 33610
Data:
September 10,2019
® WARNING -Varlly Jexi9nparzmelen anJREAO NOTES ON MS AND INCLUDED MREH REFERENCE PAGE MlFI473 nv. 1e/WR015 BEFORE USE.
Design India loruse oM rwM MTelc®rmnectora. This design is based only upon psa metere Mown, and is roan iralvival bu0tling wrtmoren4 not
abusssystem. Batons use, Me buiamgdeWgnermuMt ryMeappDMblay INdespnp mmaterswd pmpedymooryor4Mthb design mtothemnall
-•Y�
buldugdesign. B=az g4Mlsaedisto PM"M u 9INMMm dMsswebmn wMONmembenony. MditionaltemporaryarApeimm.mbraUng
MiTeK
Is adiways required tar stability.nd to prevent ceaapsewM possibdie personal lryuryand pmpeM damage. Forgeneralguidanceregarding Me
IBDdcaaon, StoreAe, delrvery,eredan end OmdrgINWssesaM Waa Systems,see ANSVRieueliiy Gr de,DS9419mdBCSIBuI/din9eomponent
69G4PaM1AEastlMd.
Sefetylnyormaddn avalableboat Truce Plata InsM 0,218N.Lee3 d,Sul.312NexandM.VA22314.
Tampa,FL M10
Job
Truss
Truss Type
any
Ply
Walsh Residence
T18074356
JM351
E05G
Hip Girder
1
1
Job Reference o tioral
�_s, ...,as„n.>o, R. Pis-, FL 34946
1-0-0 3.7-0 7-0-0 H-11-0
6.240 s uul ra m rn mu ex industries, inc. we Sep ro 09:23:46 rare Page i
ID:INmub4goEcpdh37zljasEOyIN73kcF7M00Xrsma0oE9ogUzzbOBWs3gs66E OGMsdyf4EB
16842 2143-0 251-0 2841-0
1d0 3-7-0 350 I 4-11-0
I 4-943
4-11-0 N-0
3-7-0 I
Scale= 1:50.2
5.8 =
4x8M185HS =
1x4 I
3x4 =
- -- r 4 23 24
25 5 26 27
28 296 30 31 7
4x8 =
1.4 II 3x4 = Sato=4x8M18SHS = Ass = 3x4 = 1.4 II 4x8 =
3-7-0 I 7-0-0 11--Al
-0 16A-12 2141-0 251-0 268-0
Pilate ORsets(X,Y)-
[2:0-0-0,0-0-8) [4:0-6-0,0.2-8] 17:0.5-80-2-0]
[9:0-0-00-0-121
LOADING (pat)
SPACING- 2-D-0
CSI.
DEFL,
in (loc)
gde8
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 1.00
VergU-)
0.38 12-14
>902
240
MT20
244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.87
Vert(CT)
-0.5012-14
>683
180
M18SHS
244/190
BCLL 0.0 '
Rep Stress Inv NO
WB 0.76
Horz CT)
0.14 9
n/a
We
BCDL lag
Code FBC2017/rP12014
Matrix -MS
Weight: 15411,
FT=0%
LUMBER -
TOP CHORD
2X4 SP 270OF 2.2E'Except'
7-9: 2x4 SP No.1
BOT CHORD
2x4 SP 270OF 2.2E
WEBS
2x4 SP No.3
WEDGE
Left: 2x4 SP No.3, Right: 2x4 SP No.3
REACTIONS. (Ib/size) 9=283D70.8-0, 2=294210-8-0
Max Hoa 2=106(LC 24)
Max Uplift 9=-1228(LC 8).2=1284(LC 8)
BRACING-
TOPCHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied or5-2-14 oc bracing.
FORCES. (Ib) - Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2.3=5181/2265, 34=.5272/2381, 4-5=6266/2851, 5-6=626612851, 6-7=6274/2855,
7-8=-5285/2388, 8-9=5204/2279
BOTCHORD 2-16=1945/4505, 1S-16=1945/4505, 14-15=2038/4716, 12-14=2721/6274,
11-12=2042/4721, 10-11-1966/4542, 9-10=1966/4542
WEBS 3-15=345/365, 4-15=327/630, 4-14�852/1997, 5-14=880/316, 6-12=913/319,
7.12=-857/2003,7-11=-338/644,8-11=362/380,8-10=264/90
NOTES.
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vu8=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf,, BCDL=6.Opsf; h=188; B=45ft; L=298; eave=4h; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.60
plate grip DOL-1.60
3) Provide adequate drainage to prevent water pending.
4) All plates are MT20 plates unless otherwise indicated.
5) Plates checked for a plus or minus 0 degree rotation about 8s center.
6) This truss has been designed for a 10.0 psf bottom chord live load noncencurrenl with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide
will rd between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift atjoint(s) except (jt=lb)
9=1228,2=1284.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 181 lb down and 141 Ib up at
743-0. 179111 doom and 135 It, up at 9.0-12. 179 It, down and 135 It, up at 11.0-12, 1791b down and 135 Ib up at 13b12, 1791b
down and 135 It, up at 14-4-0.179 b down and 135 It, up at 15-7d, 179 lb down and 135111 up at 17-7d, and 179 Ib down and 135
IC up at 19-7-4, and 181 Ib down and 141 Ib up at 21-8-0 on top chord, and 4081b down and 250111 up at 7-0-0, 98 ID down and 53
Ib up at 9-0-12, 98111 down and 53111 up at 11-0-12. 98111 down and 531b up at 13-0-12, 98 go down and 53 It, up at 14-4-0, 98 Ib
down and 53 Ile up at 15-74, 98 Ib dawn and 53 Ile up at 17-7-4, and 98 Ib down and 53 ID up at 19-7-4, and 408 He down and 250
Ib up at 21-74 on bottom chord. The destgn/selection of such connection device(s) is the responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
Thomas A. Albert PE No.39388
MiTek USA, Ina FL Cart 6634
69M Parke East Blvd. Tampa FL 33618
Date:
September 10,2019
97E(S
®wARNrNG-Venly design paramenere and READ NOTES ON AND INCLUDED MITER REFERENCE PAGE Mll4473 rev. I&M0ra BEFORE USE.
assess
Design Valle for use only with MTcldsoamecbrs. This dedgn Is based any upon pammelen shown. end Is for an Individual Wilding mreponeM rot
a tress system. Morgan use, the CUJding designer must verity the appG4Wilny of design peanmalen antl properly main v rate Mile design No the overall
buiedingdeslgn. Bracing indented is to prevent WckoV ofiMMdual Vasa web andlar cJnN members any AtldNonal temporary and permaneN bracNg
MiTek'
Is always requited for stabiay and to prevent collapse with possible personal IM;uryand property damage. Forgeneral guldm¢e regarding the
fabdradun,Moms. deliveryry ereation and belong b tlng Mtrossesauss systemee s,sANSy 1Duarly Cmeda,D5B419wnd BCSIBuflding Component
gave Parke East BIW.
Solsfylnharmal avauablefram Tmss PlatelnWWo.218NLee Sbeet.Sutle3lt Alexa ,VA22314.
TagOa, FL 36atb
Job
Truss
Truss Type
pry
Ply
Walsh Residence
T78074357
J36351
MV2
Valley
2
t
Job Reference (optional)
us4m w4oro miles mausmes, Inc, me bap iuua:[snB[ule Paget
ID:INmub4goEcpdh37zijesEDyIN73-h_Nun4RnNUl lf6OYVSWR2OUjsfyNKAX WSKRx Wyf4E9
2
M
2KJ G w 11
Scale = 17.8
I
LOADING (psq
SPACING- 2-"
CSI.
DEFL.
in (too)
gde0
Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.05
Vert(LL)
TUB -
Na
999
MT20 2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.03
Vert(CT)
Na -
n/a
999
SCLL 0.0
Rep Stress Ina YES
WH 0.00
Hoa(CT)
0.00
rda
Na
SCOL 10.0
Code FBC20177rP12014
Malnx-P
Weight: 6lb FT=0%
LUMBER -
TOP CHORD
20 SP No.3
BOT CHORD
2x4 SP No.3
WEBS
20 SP No.3
REACTIONS.
(Ib/stze) 1=6212-0-0, 3=6212-0-0
Max Horz 1=24(LC 8)
Max Uplift 3=11(LC 8)
Max Gmv 1=62(LC 1), 3=63(LC 13)
FORCES. (Ib) - Max. Comp.JMax. Ten. -All forces 250 (Ib) or less except when shown
BRACING.
TOP CHORD Structural wood sheathing directly applied or 2-M cc incline,
except end verticals.
BOTCHORD Rigid ceiling directly applied or 10-0-0cc bracing.
NOTES-
1) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=9.Ops/; BCDL=6.Opsf h=18ft; B=451t; L=24ft; eave=oft; Cat.
II; Exp B; Encl.. GCpi=0.18; MWFRS (directional); Cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection Conditions. It is
the responsibility of the fabricator to Increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires Continuous bottom chord bearing.
5) This truss has been designed for a 10.0 pat bottom chord live load noncencumenl with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 1001b uplift at joint(s) 3.
Thomas A Albanl PE No.39381)
MiTek USA, Inc. FL Cort 6634
69U Parke East Blvd. Tampa FL 33610
Data:
September 10,2019
®WARNING - Verllx Oesign Para meters AdREAD NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 nv, 1"312e15 BEFORE USE.
Design vane ref Use Only WO MTeMCorrnectGR. ThIS design is based prat/ Mean pdtamerers antler. and Is firm gdeshaI WYNIIg CompoMN, Ad
a Wss system. Safga Use, the budding designer mull Venythe apparabllty ofdesign parameters and pmped AWrp)mte Nis design eao me overall
buid'mgdesign. BmGn9 irdkated lsdpreVSM buodngmmd'MWal Waa web andla Ubm memben pray. Adixtraltemppmryandpemgnembrachg
MiTek'
is afeaya required for stability and d Moved maapse wah passible personal injuryand pmpedy damage, Forgenemlgudancaregamingthe
fabrication.momge,delivery eremon and bending efWsses and buss systems, add ANSUIPH CuatiryCroons, DS"9 end BCSl Building Component
Salary lnrormagan TmSSMMOIAVWe.218NLeee
69o4 Parts East IVA.
awabMh M,Sube312Alexandda.VA22314.
Tampa. Fi. Seen)
Job
Truss
Truss Type
Gty,
Ply
Walsh Residence
T78074359
J38351
MV4
Valley
2
1
Job Reference o banal
u=sa rr. rto . r�.r.=.o
2x3 i
..'Au s 4unRzms Muexmdusmes,md. iueseptuu9:e4tbtzuta Paget
10:INmub4goEcpdh37zljasE0yIN73SZ2OP6UfgPPtWL77aD48gf68ctwGXXGy8lz7Yryf4E6
2x3 II
Yl
3
Scale = 1:12.8
I
LOADING (pal)
SPACING-
2-0-0
CSI.
DEFL.
In (loc) Vde8 Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.40
Vert(LL)
nha - We 999
MT20 244/190
TCDL 20.0
Lumber DOL
1.25
BC 0.21
Vert(CT)
that - n/a 999
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Hom(CT)
0.00 n/a nha
BCDL 10.0
Code FSC2017/TPI2014
Matrix-P
Weight: 141b FT=0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 4-0-0 oc pudins,
BOT CHORD 2x4 SP No.3
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0.0 oc bracing.
REACTIONS. (lb/size) 1=162/4-0-0, 3=162/4-0-0
Max Ho¢ 1=62(LC 8)
Max Uplift 3=28(LC 8)
Max Gray 1=162(LC 1), 3=164(LC 13)
FORCES. (Ib) - Max. CompJMax. Ten. -Ali forces 250 (Ib) or less except when shown.
NOTES.
1) Wind: ASCE 7-10; Vuh=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsg BCDL=6.Opsf; h=18ft; B=45ft; L=24ft; eave=411; Cat.
II; Exp B; End., GCpi=0.18; MWFRS (directional); cantilever leftand right exposed ; Lumber DOL=1.60 plate gnp DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to Increase plate sizes to account for mesa factors.
3) Plates checked for a plus or minus 0 degree notation about its center.
4) Gable requires Continuous bottom chord bearing.
5) This truss has been designed for a 10.0 pat bottom chord live load noncencurrenl with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide
Will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) 3.
Thomas A. Albani PE No.39380
MiTak USA, Inc. FL Carl 6034
6904 Parise East Blvd. Tempe FL 33610
Bate:
September 10,2019
® WARNING -verify design Paramalwa and READ NOTES ON TMS AND INCLUDED a11TER REFERENCE PAGE Me 7473 rev. 10ION2015 BEFORE USE.
Design valid forum any with MReMeconnedo s. This design Is based Only upon pardmelers shown, and Is for an Individual building Component not
��®®
abusssyatem.Befareuse;iMbdWNgdeslpner MUAv MeappGr iblyafdesignpare em MdpmpedyhwN mtemisdedg WtomeawWI
myY�
buiWingdesgn. Bracing Indicated is to prevent tucking aflnfyydividual buss web anNatlmrd members my. Addilbltal tempareryand pelmanentbedhp
MOW
isalwaysre uW kr9ablWyarktopMv MmffapwwMpossiblepmws llyd l andpmpeMdamage. Forgeneralgukanceregarding Ite
intonation. storage, deevery, eledion and braWg Mtmsses and truss systems,see ANSVIT41 Duafdy OYNeda, DSBd9 and BCS1 Bulld/ng Component
Gaol Parts East Owl.
SNeylMormaflon available ham Tmss Rate Mrs Wo, 21e N. Lee shed, Suae 3lZAlexandra, VA 22314,
Temp., FL 06610
Job
loss
Tmss Type
Dry
Ply
Walsh Residence
T16074360
J38351
MV6
Valley
1
1
Job Reference lDotlDnall
test Goa5t Iwas. YL Vnmce, Y!_M9p
8.240 s Jul 14 2019 Mil-ek Industries, Inc. Tue Sep 10 09:23:52 2019 Page 1
ID: INmub4goEcpdh37zljasEOyjN73-ZmCOCSU IR0(j8jhJ8xbNDSeFBHACG_WSMyjg4Hyf4E5
3
2x3 i 2x3 II
LOADING (psQ
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
Vde8
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.67
Ven(LL)
n1a -
n/a
999
TCDL 20.0
Lumber DOL
1.25
BC 0.58
Vert(CT)
n/a -
Iva
999
BCLL 0.0
Rep Stress Ina
YES
We 0.00
Hoa(CT)
0.00
n/a
Na
BCDL 10.0
Code FBC201TTPI2014
Matrix-P
LUMBER- BRACING -
TOP CHORD 20 SP No.2 TOP CHORD
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3 BOT CHORD
REACTIONS. (lb/size) 1=262/6.0.0, 3=262/6."
Max Hoyt 1=100(LC 8)
Max Uplift 3=46(LC 8)
Max Grav 1=262(LC 1).3=265(LC 13)
FORCES. (to) - Max. Comp./Max. Ten. -Aft forces 250 (lb) or less except when shown
Same = 1:17.8
PLATES GRIP
MT20 244/190
Weight 211b FT=0%
Structural wood sheathing directly applied or 6-0-0 0o purlins,
except end verticals.
Rigid ceiling directly applied or 10-D-0 oc bracing.
NOTES-
1) Wnd: ASCE 7-10; Vuh=160mph (3-second gust) Vasd=124mph; TCDL=9.Opst,, BCDL=6.Opst, h=18ft; B=45ft; L=24ft; eave=oft; Cat.
it; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection Conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires continuous bottom chard bearing.
5) This truss has been designed for a 10.0 psf bottom chard live load nonconcument with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Wit Tit between the bottom chord and any other members.
7) Provide mer�haniral connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) 3
Thomas A. Aibani PE No.39380
MiTek USA Inc. FL Cart 6634
69U Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING -Vedry Qesipn paramalers and READ NOTES ON IRIS AND INCLUDED MITEK REFERENCE FAGEMM114T3 rev. I"MOIS BEFORE USE.
Design valid truss antywdh ViTeltaacobnectols. This design B based ony upon paamelers shown, end la fro en indivklual bugling component nth
atmusystem. Before asathe buildingdeelgnermuMvanlylhe appliobildyrAdesign parameters and pmpedy, hoomrsle ImSdedgn into Dao,aml
bulldhgdeslgn. Baamg ndicaledlstoprewMbualing eflnewiduallmasweb anWarchand membersony. AGdilbnaltempoaryand pennanentbacing
Welk*
Is always required for stability and to pmvem earapm with possible personal injuryand property damage. For genial gulamme regaNirq the
falmortan, stmarl delivery, eredin, and baling afbmsea and buss"ams, see ANSUIPH Duelllyafteda, DS1129 and RCSI Building Component
6904 Parke East Blvd.
Sohylnlarmmion areaable Rom Toss MMl InstaNe,218N.t Sbeet,Suae312,Aloandr ,VA22314..
Tampa, FL MID
Job
Truss
Truss Type
Oty
My
Walsh Residence
T18074361
J38351
MV8
Valley I
1
1
Job Reference (optional)
0
.44us4ui ir<u IUMIcrinausmes,mc lueaepiuua:za:.,u,B rage,
b4 ID:INmugoEWdh37zljasEOyjN73-1yMgoVwCOfamtGVie5d4BSlgcS7GiF cSEgyf4E4
Scale=1:2 e
5 4
m ' ix4 II 2x3 II
LOADING (psf)
SPACING. 2-0-0
CSI.
DEFL.
in (loc)
Udefl
Ltd
TCLL 20.0
Plate Grip DOL 1.25
TC 0.45
Vert(ILL)
We -
n/a
999
TCDL 20.0
Lumber DOL 1.25
BC 0.22
Ven(CT)
Na -
n/a
999
BCLL 0.0 '
Rep Stress Ina YES
WB 0.07
Horz(CT)
0.00
n/a
Me
BCDL 10.0
Code FSC2017/rP12014
Matrix-P
LUMBER-
BRACING.
TOP CHORD
2x4 SP No.3
TOP CHORD
BOT CHORD
2x4 SP No.3
WEBS
2x4 SP No.3
BOTCHORD
OTHERS
2x4 SP No.3
REACTIONS.
(Ib/size) 1=120/8-0-0, 4=150/8-0-0, 5=453/8-0-0
Max Horz 1=138(LC B)
Max Uplift 4=26(LC 8), 5=79(LC 8)
Max Gran, 1=120(LC 1), 4=152(LC 13). 5=459(LC 13)
FORCES. (Ib) - Max. Comp./Max. Ten. -. All forces 250 (lb) or less except when shown.
WEBS
2-5=-368/134
PLATES GRIP
MT20 244/190
Weight: 31111 FT=0%
Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 Be bracing.
NOTES-
1) Wind: ASCE 7-10; VuH=160mph (3-second gust) Vasd=124mph; TCOL=9.0psF BCDL=6.Opsf; h=18ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Erp B; Encl., GCpi=0.18; MWFRS (directional); Cantilever left and right exposed ; Lumber DOL=1.60 plate gnp DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires Continuous bottom chord bearing.
5) This truss has been designed for a 10.0 lost bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joints) 4, 5.
Thomas A. Albert PE No.39380
MiTek USA, Inc. FL Cert 66M
6904 Parke East Blvd. Tampa FL 33610
Data:
September 10,2019
®WARNING- lwldvdwfgn parom rem and READ NOTES ON MIS AND INCLUDED MITEK REFERENCE PAGE MI14473 my. 1a/nY3015 BEFORE USE.
Design valid far use onywilh MITek®oonne ors. This design is based only upon parameters shown, and is for an Individual building component,nth
a truss system. Befam use, the building designer mustwny ale applicability N design paramefars and prepedyinmmonse she design into the overall
buildingdesign. BracNg Mounted is to prevent butldog of individual truss web ands word members only. Adediona temporary and permanent bradng
MiTek'
Is always requlred far stabiNy and to prewnt collapse with possible personal inlury and property damage. For general guidance regarding me
lidaoaaon, storage, delivery. erection and bradrg Nbusses and buss systems. aee ANSf/rPlf Duality Cdfeda, OSBA9 and SCSI Building Connamerd
6904 roe East Blvd.
Saretybformaffon available from Truss Plate lnstbule, 218NLea SIreN, Su4e 312, Nexandna, VA 22310.
Taws. a6610
Tampa.
Job
Truss
Truss Type
Ory
Ply
Walsh Residence
T18074362
J38351
MV10
Valley
7
t
Job Reference (optional)
u s4m wquremuexmcusmes,mc. tuesepiuua:zq:nrzuly rages
ID:INmub goEcpdh37zljasEOyIN73-CopVZkR9uWR2ypMLN?CWpzOVGX6bjwMDg?vO4yf4EA
Scale=1:28.6
3
2x3 �; 5 q
1x4 11 2x3 II
LOADING (psf)
TCLL 20.0
TCDL 20.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0.0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Ina YES
Code FBC2017/TPI2074
CSI.
TC 0.66
BC 0.35
VJ8 0.09
MaMxS
DEFL.
VeIt LL)
Verl(CT)
Horz(CT)
in (roc) Well L!d
ma - flat 999
nda - f/a 999
0.00 4 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 401b FT=O%
LUMBER-
BRACING.
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc Puffins,
BOT CHORD 2x4 SP No.3
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 ac bracing.
OTHERS 2x4 SP No.3
REACTIONS. (Ib/size) 1=168/104-0, 4=197/10-0-0, 5=559/10."
Max Harz 1=176(LC 8)
Max Uplift 4=-35(LC 8), 5=98(LC 8)
Max Grew 1=168(LC 1). 4=199(LC 13), 5=565(LC 13)
FORCES. (lb) - Max. CompJMax. Ten. -All forces 250 (Ib) or less except when shown.
WEBS 2-5=-447/161
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsh, BCDL=6.Opsh h=18ft; B=45ft; L=240; eave=4111; Cat.
II; Exp B; Encl., GCpF:0.18; MWFRS (directional); cantilever left and fight exposed; Lumber DOL=1.60 plate gnp DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrerd with any other live loads.
6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 He uplift at joint(s) 4, 5.
Thomas A. Alban! PE No.39389
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 31010
Date:
September 10,2019
®WARNING -Verify tlevgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 1&I-0473 rev. 1WG312e15 BEFORE USE.
Design valid for use only wM MTek® connedars. This design Is based only upon parameters shown, and is for an individual bugdirg component not
a mass system. Before use, the building deSgner must verlythe approbift of deep parameters and proped&wr rme this deal, mm the overall
buildingdesign. Bracing indicated late prevent buWing or mdlmdualtruss web anderchord members only. Addnionaltemporeryandpermanentbracing
MiTek-
Is always required for stability and to prevent maapse with possible personal injury and property damage. For general guida ea regardir l
fabrication. Storage, delivery, erection and bratty Mousses and buss systems,see ANSVIPIf Dually Crneda, USba9 and SCSI Building Component
Beat Parke East Blvd.
SMefylnfnrmdlon a bblefrom Trues Plata Inablate,219N.Lea Sired,Sufte312,Alexandria,VA22314.
Tampa, FL 36610
Job
Truss
Truss Type
City
Ply=1heT18074363
J38351
MV18
Valley
1
(optional)
5.240 s Jul 142019 MiTek Industries, Inc. Tue Sep 10 09:23:48 2019 Paget
ID:INmub4goEcpdh37zliasE0yjN73-h Nun4RnNU11f60Yv5WR2OUj4fyUKAXWSKrrxWyf4E9
flM
b3 i
6-+1G73RSI
LOADING (pat)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
gde0
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.04
VertI LL)
n/a -
n/a
999
MT20 2441190
TCDL 20.0
Lumber DOL , 1.25
BC 0.02
Vert(CT)
n/a -
Na
999
SCLL 0.0 '
Rep Stress Ina YES
WE 0.00
HOR(CT)
-0.00 2
DIG
n1a
BCDL 10.0
Code FBC2017rTP12014
Matrix-P
Weight: 4111 FT=0%
LUMBER -
TOP CHORD
2x4 SP No.3
BOT CHORD
2x4 SP No.3
REACTIONS.
(lb/size) 1=52/1-8-0, 2=42)1-8-0, 3=10/1-8-0
Max Hoe 1=20(LC 8)
Max Uplift 2=15(LC 8)
Max Grav 1=52(LC 1), 2=43(LC 13), 3=21(LC 3)
FORCES. (lb) - Max. Camp./Max. Ten. -All forces 250 (Ib) or less except when shown.
BRACING -
TOP CHORD Structural wood sheathing directly applied or 143-0 oc puriins.
BOT CHORD Rigid ceiling diready applied or 10-M oc bracing.
NOTES-
1) Wind: ASCE.7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; B=45ft; L=2411; eave=oft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection Conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle a 6-0 tall by 2-0-0 Wide
Will fit between the bottom Word and any other members.
7) Bearing at joint(s) 2 considers parallel to grain value using ANSlrrPI 1 angle to grain formula. Building designer should verify
Capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 1001b uplift at joint(s) 2.
Thomas A. Albani PE Ng.39380
MiTek USA, Inc. FL Cart 6634
G904 Parke East BNB. Tampa FL 33610
Data:
September 10,2019
®WARNING - vainly design panmele s and READ NOTES ON MIS AND INCLUDED MITEK REFERENCE PAGE MII-7473,al IWO3Q015 BEFORE USE
Design valid for use Only With MReLffi connectors. This design Is bash only upon parameters shoan, and is (wan imirfidual building mmponeM net,.
Sal,
a lass system. Before use, tM blliWNg designer must verify the appGGblffy INdealgn Parameters and property nox,rombe this design me, Me nereal
buldingdesign. BracmgImicatedistoprevent buthlingdindi,ndualtrussivebandforohordmembers my. Additional tempormy and permanent bracing
MiTek'
is allays required for stability and to pmwM wRapse wlm possible persowl Injury and pmpemy damage. FOrgeneralguidamoregardingthe
labn.flim.Storage. deanery. erection and bracing ofWsses all truss systems,see ANSIRPIf Duality Criteria, DS"9 and Best Building Component
Safetylnlarmadon avarlaOle iron Tmss Plate ln9aule, 218 N. Lee Slreel, auae 312, Alexandria, VA 2914.
6904 Parke East Slid.
Tampa, FL W10
Job
Truss
Truss Type
Qty,
Ply
Walsh Residence
T18074364
J38351 J.
MV38
alley
1
1
Job Reference (optional)
as i
0
.e5u s Jung zU,v mnex mausmes, Inc. me Jep 1uuv:2.LJu zultl Vogel
ID:INmubE0 4goEcpdh37zijasyjN73dNUeCmT1v5HOVPYwiWZv7RZ?BTbio4lpveEZ?Pyf4E7
2x3 II
tJ
3
Scale: 1'=1'
LOADING (psf)
SPACING-
2-0-0
CSI.
OEFL,
in (loc)
VdeO
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.32
Vert(LL)
Na -
Na
999
MT20 244/190
TCDL 20.0
Lumher00L
1.25
BC 0.16
Vert(CT)
rda -
Na
999
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT)
0.00
n/a
n/a
BCDL 10.0
Code FBC20177TPI2014
Matrix-P
Weight: 121b FT=0%
LUMBER-
BRACING -
TOP CHORD
2x4 SP No.3
TOP CHORD
BOT CHORD
2x4 SP No.3
WEBS
2x4 SP No.3
BOT CHORD
REACTIONS.
(lb/size) 1=145/34&0, 3=145rM-0
Max Horz 1=55(LC 8)
Max Uplift 3=-25(LC 8)
Max Grav, 1=145(LC 1), 3=147(LC 13)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown
Structural wood sheathing directly applied or 3-8-0 oc purlins,
.except end verticals.
Rigid ceiling directly applied or 10-0-0oc bracing.
NOTES.
1) Wind: ASCE 7-10; VuR=160mph (3-second gust) Vasd=124mph; TCDL=9.0psf, BCDL=6.0psf, h=18tt; B=4511; L=24ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection Conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurtent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3.
Thomas A Albani PE Nc.39380
MiTek USX Inc. FL Cart 6034
6904 Parke East Blvd. Tampa FL 33670
Date:
September 10,2019
®WARNING- Verify designparemerers anOREAD NOTES ON THIS AND INCLUDED MITEx REFERENCE PAGE MU-7473 rev. IOIOMO15BEFORE USE.
Design valid fcruse onywnb MRekS lannectora This design is based only upon pammMm shown, and is for an IMividuad buitGng componem, nod
��-
a Vuss system. Before use, this buildOg designer must v rdythe appgrabilxy of design parameters end propedy mee"I i this deep bdothe overall
buildmgdesign. Braiding Indicated into p(evem tucMing of individuadbuss web andrar Nord members only. MdNonaltempomWandpermanembradng
MiTek'
is always required for stabilhy and to prevent collapse with possible personal injur and papedy damage. Forgenerelguidancoregardingthe
tabdcoaon,sbrage, degvery,eretlion and bating of WsseseM boas systems.see ANSlinlif Quality Crtteda, DSB89 and SCSI Building Companerrt
sacs Parke East BIM.
Salelyhawwegon aviUbleI Truss Plate IngMe,218NLee Street.Suds312,Alexandria,VA22314.
Tampa, FL 35810
Job
Truss
Truss Type
pty
plyA]WalsheT18074366
J38351
PB2
Piggyback
2
(options[)
ua, r•. n=, Luc=-,o d.Z4u s JUI 14 ZU18Mll¢Nlneustnes,lne. Nebep1009:23:542019 Pagel
ID:INmuMgoEcpdh37zliasEOyjN73-V8k917 WYzKnRN I riGMdrlHkhv4_muaOgGCn8Ayf4E3
scale =1:17.6
4,e4 = 4x4 =
3 4
8 7
2x4 = 1x4 II 1.4 11 2x4 =
LOADING (psp
SPACING- 2-D-0
CSI.
DEFL-
in
(roc)
UdeO
L/d
PLATES GRIP
TCLL 20.0
Plate Gnp DOL 1.25
TC 0.21
Vert(LL)
0.00
6
Nr
120
MT20 244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.08
Ven(CT)
0.01
6
Nr
120
BCLL 0.0 '
Rep Stress Ina YES
WB 0.03
Horz(CT)
0.00
5
n/a
n/a
BCDL 10.0
Code FBC20177TPI2014
Matrix-P
Weight: 291b FT=0
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudin, except
BOT CHORD 2x4 SP No.2 2-0-0 oc purlins (6-0-0 max.): 3-4.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-M oc bracing.
REACTIONS. All bearings 7-2-15.
(lb)- Max Hart 2=46(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 2, 5, 8, 7
Max Grav All reactions 2,90 Ib or less at joint(s) 2, 5, 8, 7
FORCES. (lb) - Man. Camp./Max. Ten. -All forces 250(I1b) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design. -
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=9.Ops1; BCDL=6.0psf, h=18ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcufrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
8) Provide mechanical connecUon (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 2, 5, S. 7.
9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
10) Graphical pudin representation does not depict the size or the orientation of the pudin along the top and/or bottom chord.
Thomas A Albert PE Nd.39380
MiTek USA, Ina FL Cart 6834
9904 Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING -Verily design Parameters and READ NOTES ON THIS AND INCLUDED M1IITEK REFERENCE PAGE M14I473 rev. I&M015 BEFORE USE.
'
Designyaidf UwonywMMReMCdnnWOm.Tbsdesign Isb Monlyuponparametemshown,andis MraniMivkual W9diNcomponentnot
Lai
a truss system. Befine use, no building designer must verify no app9eabirty of design parameters and pmpeMm Nryered missionNis design hold Na drdi
buildingdeugn. Bracing indicated is to prevent Waling clindMdualbuss web andlor Nord members Dommry carry. Mramenaltepdandpemsanembmoing
MiTek'
Is always required cor Mobildy and to prevent ordapse wen posdele personal injury and property damage. Fdrgenmuguidanceisgareingtba
fabrication, Storage, dethery, erepion and bmdng of Wsses and also systems. see ANSV7711 Quality Cnrerta, DS849aDo BCS1 Building Compdneat
6904 Parke EeSt Blvd.
SsreylnTomlffilon av able hdm Truss MMe inStkWO, 218 N. Lea sheet S ft83l2, Me drla, VA22S14.
Tampa, R 36610
Job
Truss
Truss Type
Qty
Ply
Walsh Residence
T78074367
J38351
PB3
Piggyback
7
1
Job Reference (optional)
u240 B Jul 14 2019 MiTek Industries, Inc. Tue Sep 10 09:23:552019 Page 1
ID:INmub4goEcpdh37zljasEOyjN73-zLIXFTXAkdvl7AQup394gVGrMUIKTLWy3wxKhcyME2
3x4 =
6
2x3 = 1.4 II 2x3 =
9-1-10
LOADING (par)
SPACING. 2-G-0
C51.
DEFL,
in
(loc) Udell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.29
Vert(LL)
0.01
5 nfr 120
MT20 2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.13
Vert(CT)
0.02
5 air 120
SCLL 0.0 '
Rep Stress Ina YES
WB 0.05
Horz(CT)
0.00
4 We Na
BCDL 10.0
Code FBC2017/TPI2014
Matrix-P
Weight: 281to FT=0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 cc pudins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 1D-0-0 cc bracing.
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 2=235/7-2-15, 4=235/7-2-15, 6=344/7-2-15
Max Horz 2=-53(LC 6)
Max Uplift 2=-57(LC 8), 4=57(LC 8)
FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 (Id) or less except when shown.
WEBS 3-6=254/43
NOTES.
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuft=160mph (&second gust) Vasd=124mph; TCDL=9.Opsf, BCDL=6.Opsf; h=18ft; B=4511; L=24ft; eave=oft; Cat.
11; Exp B; Encl.. GCpi=0.18; MWFRS (directional); Cantilever left and right exposed ;'Lumber DOL=1.60 plate grip DOL=1.60
3) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection Conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) Gable requires Continuous bottom chord bearing.
6) This truss has been designed for a 10.0 par bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Will fit between the bottom sham and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate Capable of wlthstanding 10016 uplift at joint(s) 2, 4.
9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
Thomas A Albani PE N%39380
MiTek USA, Inc. FL CeM6634
6904 Parke East Blvd. Tampa FL 33610
Data:
September 10,2019
AWARNING -Vann, design paiamerers and READ NOTES ON THIS AND INCLUDED MITEKREFERENCE PAGEMII-7413 rev. 10/0]rzOfS BEFORE USE.
'
Design valid far use only wet Miracle conneMors. This design is based any upon parameters shown, and Is for en indivlduM builting Componen4 net
Lai
a Dun system. Before use, the building designermust vefiy the appacabift x6foign parameters and properly reception. This design ka ina overall
buiMmgdeslgn. BmdngindaratedislopmwMWu iingof NdindualhusswMw&orchodmem mwrs ,. Addinonaltemporarya,dperanneMbrasing
MOW
shows requited for stability and to preva d Collapse wet possible personal injury and property damage. Forgeneral guidance regarding me
fabrication, 9orage,delivery, emaOon Cotl broil, ofhusae, and truss system, see ANSM11 dually, CCRda, DSB-B9 and SCSI Building Component
6904 Parke East Blvd.
SMeylnfomration available ham Truss Plate Institute, 218 N Lee ahem, Suite 312, Alexandra; VA22114.
Tampa, R Sol
Jab rugs
Truss Type
Dty
Ply
Walsh Residence
T18074368
J38357 V1
Valley
1
t
Job Reference (optional)
s, me we out,m ue:w:x mIa rage i
ID: INmub4goEcpdh37zljasEOyjN73SXNSpYOVx19dK74NmgJNip4MugVCoWhHahuD2yf4E1
6.00 12
2x3 i
2
3
Scale =1:6.1
LOADING (pat)
SPACING- 2-0-0
CSI.' I
DEFL.
in (hoc) pde0 Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.02
VailWe
- Na 999
MT20 244/190
TCDL 20.0
Lumber DOL 1.25
SC 0.01
Vert(CT)
We - n/a 999
BCLL 0.0 '
Rep Stress Ina YES
WB 0.00
Horz(CT) -0.00 2 Na , n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix-P
Weight: 3lb FT=O%
LUMBER-
BRACING-
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural mod sheathing directly applied or 1-4-0 cc putting.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0cc bracing.
REACTIONS. (lb/size) 1=36/1-4-0, 2=29/1-", 3=7/1-4-0
Max Horz 1=14(LC B)
Max Uplift 2=11(LC 8)
Max Great 1=36(LC 1), 2=29(LC 13), 3=14(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less
except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; B=45ft; L=24ft; eavese4ft; Cat.
It; Exp B; Encl., GCpi=0.18; MWFRS (directional); Cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection Conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 pat bottom chord live lead nonconcurrent with any other live loads.
6) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide
will lit between the bottom chord and any other members.
7) Bearing at joints, 2 Considers parallel to grain value using ANSpTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical Connection (by others) of truss to bearing plate Capable of withstanding 100111 uplift at joint(s) 2.
Thorns, A Wbani PE No.39360
MiTek USA, Inc FL Cart0634
6906 Parke East Blvd. Tampa FL 33610
Date:
September10,2019
AW UB dNG -Verily design paramems,s and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MIF7473mv 10,014015 BEFORE USE.
Benign wild argues onywah MTeMomnectors. This design Is based ony upon parameters shown, and Is bran usliVeure buOding component, nd
��•
a truss system. Before US,Ore building designer must very the apphiscoll of design parameters and properly Ncrmrrate this design into the evema
��-��.YYY■
tiuildingdeelgn. Bracing lnliemers is to prevent bantling of mdivldual truss web Earlier Hard members only. AddWnaltemprmryaWpmmanedbracblg
MiTek'
Is aMays ms air d for stably and to prewem cogap. wtlh possible personal injury and pmpEM damage. For general guWe. regaNiig the
fabrication, Storage, delivery, eadagn end baseball of tromeS and truss systems, see ANSUTPN duality Crfieds, DSB89 and SCSI Building Component
69g4 Padm East BIM.
Sefeylnformatren ..IA bkemm Truss Plataln93We,218N.Lee Stmet.Suae312A1exandaia.VA22314.
Tampa.R. 38610
Job
mas
T1uss Type
Dty
Ply
Walsh Residence
T18074369
J38351
V3
Valley
1
1
Job Reference (optional)
6Z4U s Jul 14 ZU19 MI I ex industries, Ina I ue Bep 1U U9:24:UB 2U19 f age 1
ID:INmub4goEcpdh37zijasEOyjN735mFZzwhKgdYS3AwO4lt7sEJ5ojrVODUS2Rb WdMyf4Dr
Scale=1:11.1
3
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (too)
VdeB
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.24
Vert(LL)
n1a -
Na
999
MT20 2441190
TCOL 20.0
Lumber DOL 1.25
BC 0.12
Ven(CT)
n/a -
n/a
999
BCLL 0.0
Rep Stress Incr YES
NB 0.00
Horz(CT)
0.00
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-P
Weight: ll lb FT=0%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOTCHORD 2x4 SP No.3
WEBS 2x4 SP No.3 BOTCHORD
REACTIONS. (Ib/size) 1=128/3-4-0, 3=128/3-4-0
Max Ho¢ 1=49(LC 8)
Max Uplift 3=23(LC 8)
Max Gmv 1=128(LC 1).3=130(LC 13)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown
Structural wood sheathing directly applied or 3-4-0 oc purlins,
except end verticals.
Rigid ceiling directly applied or 10-D-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCD1_=9.0psf; BCDL=6.Opsf; h=18ft; B=45ft; L=2411; eave=4ft; Cat.
11; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and fight exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection Conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its Center.
4) Gable requires Continuous bottom chord bearing.
5) This truss has been designed for a 10.0 par bottom chord live load nonwncurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf an the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) 3.
Thomas A- Albani PE No.39380
MITak USA; Ina FL Cart6634
9904 Parke East Blvd. Tampa FL 33610
Data:
September 10,2019
®WARNING - Verily 0esignpammefers and READ NOTES ON THIS AND INCLUDED MITEK REFERENCEPAGE VS7473rov IMM015 BEFORE USE.
Design wIM for use ontywM Mirek®connectore.Thisdesign is based ony upon pammNereshown, and is for an individual building campanem, not
abuse system. Before use,the building designer must verify the app@sblliyofdefippemmetessend property mom arelethisdesign docitheoverall
Flo
building design. Bracing(Wicated is to prevent burkbng ofindiImSiltrusswebandlachoNmeritsmony. AddNonitimSpowyaMpemimentbracmg
MiTek'
IsalwaysmqulredfarslabiNyandloprevaramllap.WAhpossiblepe=mlMlugwdpmpedydamage. Forgenemlgukanceregardily Ne
fabrication, Storage. delivery, election and bmdng oftmsses and buss systems,see ANSUTPH Qualify CMeda, DSB89 and BCV Building Component
6904 PaAa Earl Blvd.
Saflyrafneadon avalableham Toss Plate Ingdu0,218N.LeeS 0,Suite312,Alexandra,VA22314.
Tampa. FL 36610
Job
rasa
Truss Type
Oty
ply
Walsh Residence
T18074370
J38351
V4
Valley
1
1
Job Reference o tional
O.Lqu aJ-114 Lm a mii eK maustries, Inc. I us sep 1 u 09:2q:u02ul V rages
ID:INmub4goEcpdh37zljasEOyjN73-SraRzwllKgdYS3AW 04It7sEJ6bjksODUS2RbWdMyf4Dr
2x4 =
2
Base =1:7.7
LOADING (pst)
SPACING- 200
CSI.
DEFL.
In (loc)
VdeO
Lld
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.06
Vert(LL)
Na -
nla
999
MT20 2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.17
Vert(CT)
n/a -
last
999
BCLL 0.0 '
Rep Stress Ina YES
WE 0.00
Hom(CT)
0.00 3
Na
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-P
Weight: 11 lb FT=O%
LUMBER.
TOP CHORD 20 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 1=138/400, 3=138/400
Max Harz 1=17(LC 6)
Max Uplift 1=11(LC 8).3=-11(LC 8)
FORCES. (Ib)-Max. Comp.lMax.Ten.-All forces 260(lb) or less except when shaven.
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc pudins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wnd: ASCE 7-10: VuH=160mph (3-second gust) Vasd=124mph; TCDL-9.Opsf; BCDL=6.Ops1; h=18ft; B=4511; L=24ft; eave=oft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to Increase plate sizes to account for these factors.
4) Plates checked for a plus or minus 0 degree rotation about 8s center.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 200 wide
will rn between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) 1, 3.
Thomas A Albani PE No.39390
MIT* USA, Inc FL Carl e634
6904 Padre East Blvd. Tampa FL 33910
Date:
September 10,2019
®WARNING. Venly de519nparamwers anOREAD NOTES ON THISANDINOLUDED MITEK REFERENCE PAGE MII-0473 n¢ 10,030015 BEFORE USE.
assign valid for use 0ntywah MReMoannactors. This design Is based only upon panmalers shown. and Is foran hx lW uai annam mmponeq not
�]e�
a Voss system. salons use, the btdiding designer midwsifytha epplaabifayofdesgn pammelers and pmpedy wMerale this design into Na o"Mil
■�;;Y�
bWkngdesign, Bracing iMicated is to plownt buoldi of Individual tma9 web andfor daN member only. AddalanallempomryeiMpennanomionsng
Mllek•
isaWMregubedbfstabifyandtopre MmaapwwMpossiblepersonalinlurymdpmpeydamage. ForgeneralguidanOeregamingma
faMragon,storage, deMery, erection antl among oftnums and buss systems,aee ANSITTPII Dually CMods, DSBA9 and BCSI Building Component
6901 parts East BW.
Saleylnsomatlon avagablelmm Tmss PMeln=We,21a N.Loe maLSuae312,Nexmdda,VAM14.
Tampa, FL 36610
Job
Tnlss Type
Piy
Walsh Residence
[as
T1807437f
J3B351
VS
Valley
1
ID
1
Job Reference (optional)
a Gap .ua:'R:aa'Ore raga1
10:INmub4goEcpdh37zijasE0yjN73-Z18gBGiyRxgJgKVae7PMPSr5770vlgkcHSK49oyf4Dq
Scale =1:16B
2
3
2x3 i 2x3 II
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
Well
Ud
PLATES GRIP
TOLL 20.0
Plate Grip DOL 1.25
TO 0.85
Vert(LL)
n/a -
n/a
999
MT20 2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.43
Vert(CT)
ma -
n/a
999
SCLL 0.0
Rep Stress Ina YES
WB 0.00
Hoa CT)
0.00
ma
ma
BCDL 10.0
Code FBC2017rTP12014
Matrix-P
Weight: 191b FT=0%
LUMBER.
BRACING -
TOP CHORD
2x4 SP No.3
TOP CHORD
BOT CHORD
2x4 SP No.3
WEBS
2x4 SP No.3
BOT CHORD
REACTIONS.
(lb/size) 1=228/5-0-0, 3=228/5-4-0
Max Hom 1=87(LC8)
Max Uplift 3=40(LC 8)
Max Grav 1=228(LC 1), 3=231(LC 13)
FORCES. (Ib) - Max. COmpJklax. Ten. -All forces 250 (ID) or less except when shown
Structural wood sheathing directly applied or 54-0 co purlins,
except end verticals.
Rigid Gelling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vu1=160mph (3-second gust) Vasd=124mph; TCD1_=9.0psU, BCDL-6.Opsf; h=1811; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.16; MWFRS (directional); cantilever left and fight exposed ; Lumber DOL-1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to Increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) a This truss has been designed for a live load of 20.Opsf an the bottom chord in all areas where a rectangle 3-6-0 tall by 240-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) 3.
Thomas A. Mbani PE No.39380
MiTek USA; Inc FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING. Ve ity design parameters and READ NOTES ON THIS AND INCLUDEDMITEx REFERENCE PAGE haff Af?srev. 10,032015 BEFORE USE.
Design valid tar use only arm MRek® connectors. Me design Is based only upon paammers shown, and le for an InalNdual buildilg aampcnem, am
w
E
IS
a Me system. Bef ve, use. the bwldIng designer must verify are applicabilityof design paeters and property incor onge this design Into the overall
buildingdesign.BaWr) mounted Gas prevent budding or nalMdual Was web andlm lard members only. Mdhlonm temporeryaM celmanenl tracing
WOWIs
always wa lred for stealer and to prevent collapse with possible personal Injury and propertydamage. Forgenamlguldwsuregardiig0le
fabK.t.n.notag.,deavery,emdionwdbmWgoftmsses and W3a systems ANS117I1 Quality crude, DS"9 and BCS1 Banding component
Saleylydgrmaflon availabb ham Truss Plata Inamme.218 N. Lee acid, 8uae 312.Alexandiia. VA22314.
69a4 Parke East BIW.
Tampa FL 36610
Job
Truss
Truss Type
Ory
Ply
Residence
T76074372
J38351
Valley
1
1
�Walsh
Job Reference o tional
ru S del..1..vm.EhIn.11EUmS,mG me aep wua:zq:w m,B rage,
ID:INmub4gGEcpdh37zliasE0yjN73-I DICOciaCE0AIU4mCfwbxf00DX01 U7OM4diEyf4Dp
5 4
2z3 ' 1x4 II w II
LOADING (pat)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
Vdeft
Vd
TCLL 20.0
Plate Grip DOL
1.25
TC 0.38
Vertfi-Q
n/a -
n/a
999
TCDL 20.0
Lumber DOL
1.25
BC 0.18
Vert(CT)
We -
We
999
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.06
Hom(CT)
0.00
n1a
nfa
BCDL 10.0
Code FBC20171TPI2014
Matrix-P
LUMBER-
BRACING -
TOP CHORD
2x4 SP No.3
TOP CHORD
BOT CHORD
2x4 SP No.3
WEBS
2x4 SP No.3
BOT CHORD
OTHERS
2x4 SP No.3
REACTIONS.
(lb/size) 1=10817-4-0.4=13717-4-0, 5=412/7-"
Max Horz 1=125(LC 8)
Max Uplift 4=24(LC 8), 5=72(1-C 8)
Max Grev 1=108(LC 1), 4=139(LC 13), 5=417(LC 13)
FORCES. (lb) - Max. Camp./Max. Ten. - All forces 250.(Ib) or less except when shown.
WEBS
2-5=-3341122
Scale =1:21.1
PLATES GRIP
MT20 2441190
Weight: 291b FT=O%
Structural wood sheathing directly applied or 6h0 cc puriins,
except end verticals.
Rigid ceiling directly applied or 10-0-0cc bracing.
NOTES-
1) Wind: ASCE 7-10: Vuk=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; B=4511; L=24ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances Or rough handling and erection Conditions. It is
the responsibility of the fabricator to increase plate sizes to account for -these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires Continuous bottom chord bearing.
5) This truss has been designed for a 10.0 par bottom chord live load nonconcunent with any other live loads.
6)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5.
Thomas A. Albani PE No.39380
MITek USA, Inc. FL Cart 6634
6904 Padre East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING Venly desIm parameters and READ NOTES ON THIS AND INCLUDED MIT£K REFERENCE PAGE MII-7473 m, 10/OM015 BEFORE USE
'
Design valid far use onlywnt virekgbc moron. This design Is beam only upon perainetem shown, and is for en Individual building component, not
a buss system. Before use, the building designermust venfy me al), oobilityordpa esigh rameter end properly ncerixode Nis design intome overall
building design. Bracing Indicated is to prevent buckling of mdidual cuss web amlor clued members why.Amirtonal temporary and permanent bracing
WOW
Is always required for stabibty and to prevent collapse win possible personal irryury end pmpedy damage. Forgeneralguidarlceregamingthe
fabncalioq storage, delivery, eredion and bradng ofbusees ant buss systems, see ANSV7(Nt Quafity Crireda, DSB4r9 and Best Building Component
6901 Parke East Bhd.
Saferylnfanna0on available bom Truss Plate lnaNNe,218 N. Lee 51me1, Suae 312, Alexandra, VA22314.
Tampa, FL MID
Job mss
Truss Type
Cry
Ply
Walsh Residence
T18D74373
J38351 B
Valley
1
1
Job Reference (optional)
an'uod, m r surd rage 1
ID:INmub4goEcpdh37zliasEOyjN73.VOFacxjCzYw1weezlORgUt YI 13DaVukPpBEhyf4Do
4-0O 8-0-0
A." 4-0-0
Scald=1:15.1
3x4 =
2
4
2X3 i 1.4 II 2x3 11
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (Joe)
gdeg
Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.44
Vert(LL)
me -
Na
999
MT20 2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.20
Vert(CT)
We -
Na
999
BCLL 0.0 '
Rep Stress Incr YES
WE 0.05
Hom(CT)
0.00 3
n/a
n1a
BCDL 10.0
Code FBC2017rTP12014
Matrix-P
Weight: 251b FT=0%
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. (IMsize) 1=173/8-0-0, 3=173/8-0-0, 4=330/8-0-0
Max Horz 1=43(LC 6)
Max Uplift 1=28(1_C 8), 3-28(LC 8)
FORCES. (lb) - Max. Comp/Max. Ten. -All forces 250 (lb) or less except when shown.
BRACING-
TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc punins.
BOT CHORD Rigid ceiling directly applied or 10-0-0oc bracing.
NOTES-
1) Unbalanced roof live loads have been Considered for this design.
2) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf; BCDL=6.Opsf; hat Bill 6=451; L=24111; eave=oft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) Gable requires Continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load noncencurrent with any other live loads.
7) a This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3." tall by 2-0-0 wide
will fit between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100111 uplift atjoint(s) 1, 3.
Thomas A Alban! PE No.39300
MiTak USA, Inc. FL Can 6634
6904 Parke East Blvd Tampa FL 33610
Date:
September 10,2019
®WARNING -Vanity assign paramelers and READ NOTES ON MIS AND INCLUDED MITEK REFERENCE PAGE MIIJ473'e . 1m032015BEFORE USE.
Design WIN far use onywah INTek®omnerton. This design Is based any upon parameters Morn, and Is for an Msfiddual building mov omm not
a Muss system. Before use, the busing designef MMAWrify me appambg4y a diesign parameters and property Mmlpomte this design into the owratl
..Y�•
bulldingdeu,. BmdngilidimtedietopreventbucklingofNdlNdualWsawebenmwrJloNmemSersany PddahnAtemporaryalMpermanentbrazing
Wek'
Is always required for Stability and to prevent m0apse with passible personal Njury and property damage. ForgeIi n l vidanm regaldin9 the
fabrlm0on,storage. detivery, ereauon and bmdng oftmsses and buss systems,sea ANSUrP1l Quality Crkeda, DSBa9 and SCSI Building Component
6901 Papa East BM.
Saraylnhandan eat amflable from Tmss Plate InMkWa, 210 N. Lea Sheet, au4e 312 AlexandM, VA22314.
Tampa, R MID
Job
Truss
Truss Type
Oty
Ply
Walsh Residence
T18074374
J38351
12
Valley
1
1
Job Reference (optional)
024U S Jul 14 ZUIU MI I eK InaUSlneS. me. 1 IN, Uep lU Ua:Z3:b/ 2U1a
Scale - 1:21.5
M•18
3x4 O 1.4 II 3x4 1
LOADING (psf)
SPACING. 2-0-0
CSI.
DEFL.
in (hoc)
Vast
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.84
Vert(LL)
ma -
ma
999
MT20 244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.52
Vert(CT)
ma -
ma
999
BCLL 0.0
Rep Stress Ina YES
WB 0.09
Horz(CT)
0.00 3
ma
ma
BCDL 10.0
Code FBC20177rP12014
Matrix-S
Weight: 391b FT=G%
LUMBER -
TOP CHORD 2x4 SP No.3
BOTCHORD 2x4SPNo.3
OTHERS 20 SP No.3
REACTIONS. (Rd/size) 1=246112-0-0.3=246/12-0.0,4=584/12-M
Max Hom 1=68(LC 6)
Max Uplift 1=33(1_C 8), 3=33(LC 8). 4=21(LC 8)
Max Grav 1=249(LC 17), 3=249(LC 18), 4=584(LC 1)
FORCES. Qla) - Max. Comp./Max. Ten. -Aft forces 250 (lb) or less except when shown.
WEBS 2-0=416/64
BRACING-
TOPCHORD Structural wood sheathing directly applied or 5-3-4oc puriins.
BOT CHORD Rigid ceiling directly applied or 10.0-0 of; bracing.
NOTES-
1) Unbalanced mot live loads have been Considered for this design.
2) Wind: ASCE 7-10: VuR=160mph (3-second gust) Vasd=124mph; TCDL=9.Opst,, BCDL=6.OpsY h=18ft; B=45ft; L=24ft; eave=oft; Cat.
11; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) Gable requires Continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load noncencurrent with any other live loads.
7) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at Joint(s) 1, 3, 4.
Thomas A A16eni PE No.39380
MiTek USA, Inc. FL Cat6634
6904 Parke East Blvd. Tampa FL 33810
Date:
September10,2019
®WARNING -Verify design paramefers and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII44b re'. 10/e3R015 BEFORE USE.
Design wad refued only web A4Te9IDcameROm. TNe design Is based "epM pa2mNR BsboNT, and IS for an IMIMEual b Uffin, eo ,unnedl, net
�*e
a Wss system. Before use, Me building designer mualver i, applicability of deop parameters and pmpedy Nwrporeta sea design into are oswml
buidingdeslgn. Bracing indicated Is to prevent toOdingo�NMMdualtress web ands,Mind membemonry.Addalonaltemp0rery and pmmenembrecing
MITek'
b aware re,ulredfarstabibty and to grease conepsewM possible personal injuryand property damage. Fergeneralguldanceregardingtae
falamatlon,storage. deavery. erection end snaring ofkusses and Vasa systems, see ANSVTPN Qualify Cllteds, DS649 and Best auading Component
Ba51B1W,
Sareyrnbrmorlan a flablefmm Tmss Plalelns Ue.218N.Lse Sbem.B fte312.Nexandrla,VA22314.
Tam ,R
Tampa, R 36610
Job Truss
Truss Type
pry
Ply=tional)
J38351 V16
Valley2
u.c.vaaw ,. era=nn dart n,uuamo, nth, me aep rvuc.w aomm regal
Scale=1:27.9
4%4 1.4 II 2x4 II
3 10 4 5
U4 �S 9 8 7 6
1x4 II 1.4 II 1.4 II 2x4 11
LOADING (psf) SPACING- 2; CS'_
DEFL. in (too) Udell L/d PLATES GRIP
TCLL 20.0 Plate Grip DOL .25 TC 0.47 Vert(LL) n/a - n1a 999 MT20 2441190
TCDL 20.0 Lumber DOL 1.25 BC 0.27 Vert(CT) nia - rda 999
BCLL 0.0 Rep Stress Ina YES V48 0.11 Horz(CT) 0.00 6 rda n/a
BCDL 10.0 Code FBC2017fTP12014 Matrix-S - Weight: 671b FT=0%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied Or 6-" Go purlins,
BOT CHORD 2z4 SP No.3 except end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 16.0-0.
(Ib)- Max Horz 1=151(LC8)
Max Uplift All uplift 100 Ib or less at joint(s) 6, 9, 8, 7
Max Grav All reactions 250 Ito or less at joint(s) 1, 6 except 9=474(LC 13), 8=410(LC 13), 7=495(LC 14)
FORCES. (Ib)-Max. COmp.IMax. Ten. -All forces 250 (Ib) or less except when shown.
WEBS 2-9=382/138, 3-B=291/94, 4-7=330/112
NOTES-
1) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=9.OpsF BCDL=6.Opsf; h=1Bft; B=45111; L=24ft; eave=oft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water pending.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcortent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL=10.Opsf.
7) Provide mechanical Connection (by others) of truss to bearing plate Capable of withstanding 100 Ib uplift at joint(s) 6, 9, 8, 7.
Thomas A Alban! PE No.39380
MITak USA, Ina FL Cart 6634
6904 Parks East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING- Verity tlesl9n Pascoe ten and READ NOTES ON THIS AND INCLUDED MITEK NEFENENCE PAGE M0.TV3 rev. 1 &MOI5 BEF08E USE.
Design va1B far use Dais wM MTekdr connectors. This design Is based only upon parameters snovm. and is for an Individual whom, component, not
a truss system. Before Use. be b ikigdesigner must vedfy the appgcatity of design parameters and ppeM Noamonde MIS desgn into the owmfl
bull4Ngdeslgn. Bracingi,d edistoprevembuatingOhdMduWl 33webandlw Uordmembemwty. Adddonaltemporsryand,smmertlowi;
MiTek'
Is always required for stability and to preveMmllapse wM possible personal injury and propedydamage. For gene al pidame regarding the
blariratlon,storage, delivery. emotion and bredng ofbumes and Was systems,see ANSVTP/f CUaINy Cdfeda, MB49 and SCSI Building Component
Sees Parke East Blvd.
Solmyl.M.Am.n evadable fmm Trvss Plate Ina We, 21a N. Lee Blreet, Suite 312, Aleaandria, VA22314.
Tampa, FL 3aa10
Job
rvsa
Truss Type
pry
Ply
Walsh Resitleno9
T18074376
J38351
V76B
Valley
1
1
Job Reference o tional
a.zRV s 4ungzuiU mDeK InOUSUMS. Inc. 1uefiepluua:zdaazule Pagel
ID:INmub4goEcpdh37zljasEOyjN73-s6X24mhnsPkUokf2vD0?LRVa5gLP827zXvYgNyf4E_
Scale=1:27.0
4x4 =
3
3x4 i 8 7 6 3x4 Q
1x4 II 1.4 II 1.4 II
16-0-0
18-0-0
l
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in (loc)
gde8
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.40
Vert(-L)
We -
n1a
999
MT20 2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.19
Vert(CT)
n/a -
We
999
BCLL 0.0
Rep Stress Ina YES
WB 0.08
Hoa(CT)
0.00 5
Na
Na
BCDL %0
Code FBC20171TPI2014
MatrixS
Weight: 58 lb FT=0%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 60.0 0o purlins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0Go bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 1S.".
(Ib)- Max Horz 1=93(LC 7)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 6, 8
Max Grav All reactions 250 lb or less atjoint(s)1, 5 except 7=336(LC 1), 6=440(LC 14), 8=440(LC 13)
FORCES. (III) -Max. Camp./Max. Ten. -All farces 250(I1g) or less except when shown.
WEBS 3-7=-26077, 4-6=351/124, 2-8=-351/124
NOTES.
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf BCDL=6.Opsf; h=18ft; B=45ft; L=24ft; eave=oft; Cat.
11; Fxp B; Encl., GCpi=0.18; MWFRS (directional); Cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires Continuous bottom chord bearing. `
5) This truss has been designed for a 10.0 psf bottom chord live load nonconc omen with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide
will rd between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) 1, 5, 6, S.
Thomas A. Albani PE Nd.39380
MITak USA, Inc. FL Cart 6634
6904 Parke East BNB. Tampa FL 33010
Data:
September 10,2019
®WARNING - Verify d.V1,I Parameters antl READ NOTES ON TNIS AND INCLUDED MITEK REFERENCE PAGE M0.7473 rev. fa/VaOla BEFORE USE.
Design vend far use onNwah rNTek®wnnepon. Tins design Is based only upon pnm uen sMad, and is Wan Individual building component. no
�■e
awes sySem. Before use. the building destmermun WznIfie appaosbaty ofdam, parameters and poperly M.M.Cate Nis daso,m Mtd lee Dyeon
dtllding dedgn. ending indicated 13 to prevent bucding ofindmdual buaaweb vxV"ohonS members only. Midland temporary end pemosom braox,
M!Tek'
is always required forstabiliy and to prevent culapsewdh possible perso nil inkoyand property damage. Far genanl guldanoa nganlbg the
fabnration, domge, delivery. erection and nosing ofhuses and truss systems,see ANSUIP/f clueing, Crgda, DS"9 and SCSI Building Component
6904 Parke Fast Bhd.
Saferybdimmadon awllable Mom Toss Fate Indede.218 N. Lea Wed, suae 31Z AlaAmdda. VA22314.
Tampa, FL 36510
Job
na
Truss Type
Oty
Ply
Walsh Residence
T78074377
J38351
V18
Valley
1
1
Job Reference (optional)
3x4 i
o.[4U s JW 14 LV 1v Muex meusmes, Inc. l ue Sep lu uv:zq:ui zviv
4x4 =
9 10 a 7
IM II 1.4 II IA II
62x4 II
64E1ES1`l
LOADING (pst)
SPACING- 2-M
CSI.
DEFL.
in (too)
Men
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.75
Vert(LL)
n/a -
ma
999
MT20 244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.46
Vert(CT)
n/a -
Na
999
BCLL 0.0 '
Rep Stress Ina YES
WEI 0.12
Horz(CT)
0,00 6
n/a
n1a
BCDL 10.0
Code FBC20171TP12014
Matrix-S
Weight: 77 Is FT=0%
LUMBER.
BRACING -
TOP CHORD
2x4 SO No.3
TOP CHORD Structural wood sheathing directly applied or 64W GO purlins,
BOT CHORD
2x4 SP No.3
except end verticals.
WEBS
2x4 SO No.3
BOT CHORD Rigid ceiling directly applied or 10-0.0 oc bracing.
REACTIONS.
All bearings 18-0-0.
(lb)-
Max Horz 1=151(LC8)
Max Uplift All uplift 100 Ito or less at joint(s) 6, 8, 7 except 9=108(LC 8)
Max Grev All reactions 2501b or less at joint(s) 1 except 6=291(LC 13), 8=264(LC 13), 7=487(LC 14), 9=638(LC
13)
FORCES. (Ib) - Max. Camp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 47=342/88, 2-9=-484/173
NOTES-
1) Unbalanced root live loads have been Considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf; BCDL=6.Opsf; h=1Oft; B=4511; L=24ft; eave=41t; Cat.
11; Exp B; Encl., GCpi=0.18: MWFRS (directional); fanelever left and fight exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) Gable requires Continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = I O.Opsf.
8) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 It, uplift at joint(s) 6, S. 7 except
Ql=1b) 9=108.
Thomas A.Albani PE No.39300
MITek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33910
Dale:
September 10,2019
®WARNING.Verity design parameters and READ NOTES ON TWS AND INCLUDED MITEK REFERENCE PAGE Mlld473../0103120I5 BEFORE USE.
Oesign vexi for use Only with MTeM cennMors. this design Is based any upon parameters shavn. and is for an Individual Wading component not
��
a WOSystem Betasuse,iWbwMMgdOggner MUatvedy MBapparabaayVdoNplpaMm KSendproperly N=T.W.thisdesign Ntomeowout
1,01gagdesign. Br glMicatedistopMv Wr gd MMdual WsswebaWl NONmem6 Wly. AtldXbnL temporary erM pellnanerd baWg
MiTeK
Isalwayei"4 drorstebitiywdtopmwMmllapsewMposslblepmneliNUq MdpmpeMdamage. ForgeneMlpixonce Mgardingthe
fabdwaon, Morage, dalivery.ereGon and bradly of iMsseseM buss Systems,sea ANGUFPl1Quality Cdteda, DSB49 and SCSI Building Campanent
6904 Parke East Blvd.
Sereylnrarmetlon evapabb horn TMss Plata In9GMe, 218 N.lae SiMM, Suee 312 NexandM, VAYC414.
Tampa, FL 36610
Job
Truss Type
Cry
Ply
Walsh ResidenceT16074378J38351
E185A
Valley
1
1
Job Reference o tional
ASA =
3 10 11
a.ceua Jul v,m I nmueK1nuu5mex, iru. i ueaep lD Da:[R:O<[ma
Scale=1:30.4
aA II
5
3x4 i 9 8 7 6 2x4 II
1.4 II 1.4 II 1x4 II
8G8
4&12
4E-12
LOADING (pso
SPACING- 2-M
CSI.
DEFL,
in (loci
gde8
Lid
PLATES GRIP
TOLL 20.0
Plate Grip DOL 1.25
TC 0.61
Vert(ILL)
n/a -
nVa
999
MT20 244119D
TCDL 20.0
Lumber DOL 1.25
BC 0.45
Ven(CT)
n/a -
Na
999
BCLL 0.0
Rep Stress Ina YES
W3 0.14
Hom(CT)
0.00 6
n/a
n1a
BCDL 10.0
Code FBC20177TPI2014
Matrix-S
Weight: 73 IS FT=0%
LUMBER-
BRACING -
TOP CHORD
2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 0o purllns,
BOT CHORD
2x4 SP No.3
except end verticals.
WEBS
2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-M oc bracing.
OTHERS
2x4 SP No.3
REACTIONS.
All bearings 18-0-0.
(lb)-
Max Harz 1=151(LCB)
Max Uplift All uplift 100 Ib or less at joints) 6, 9, 8, 7
Max Gmv All reactions 250 lb or less at joint(s) 1, 6 except 9=466(LC 1), 8=459(LC 13), 7=639(LC 14)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-9=378/137, 3-8=320/101, 4.7=429/144
NOTES.
1) Wind: ASCE 7-10: Vuh=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf BCDL=6.0psF h=18ft; B=45ft; L=24ft; eave=oft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL-1.60
2) Provide adequate drainage to prevent water pending.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 per bottom chord live load nonconcument with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide
Will fit between the bottom chord and any other members, with BCDL = IO.Opsf.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 6, 9, 8, 7.
Thomas A. Alberti PE No.39330
MITBk USA, Inc. FL Cott 6634
6904 Parke East Blvd. Tempe FL 33610
Date:
September 10,2019
AWARNING -Verity dealga parameraa and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE red 7473 rev, IMMIS BEFORE USE.
De51gn valiel hruee onh'an MTeM Carrooh s. Hale design Is based only upon parameters aroa n. and IS for an 1Milklual Wiling Larne nam na
��eeCC
a Wsa sdoegn Barmy use, me bolding de9gnermuslverey nro eppeubllRy oltlesiyl paremetem antl pmpedyinmryoreta Nla tleslgn ltda Ne overt
-.Y�•
buildNgdeslgn.df.rNg lMiratedOp..MOV.p mgolln
rgeneral emponryeM perthe brecNg
MiTek'
iaaxvayerequrage,daM, endJopreroM wgapaewSWSand"3ersnnal
MN.alomnalebunmdpmNmemaMage. melgul, me
tlpmpemydamaef
Iabncalion,stornge. dagila,ere DSBregarding
S,See Qualify Criteria, DSBA9 and BC5l Building Component
AN.VA
6904Par
TmssMMalncMe,218MLosa0,Su,see
Sarerylnformegon evaila5le ham Truss Plate ln9nule, 2t8N Lea SIreM, 9une 313. AIexaMda, VA 22314.
14.
3east 6610 .
Tertma, FL 36a10
Job
Truss Type
Oty
Ply
Walsh Residence
Ps
T78074379
J38351
Valley
1
1
Job Reference (optional)
E..' WL5r IN5i, rl r•IC, W, PLJ.
d.2405 JUI 142U19 MI fek lndustnes, INC. TUB Sep 1009:24:032019 Pagel
4x4 =
3x4 G 111x4 II io1x4 II 1x4 119 1x4 118 7
Scale = 140.0
LOADING (psf)
TCLL 20.0
TCDL 20.0
BCLL 0.0 '
BCDL 10.0
SPACING. 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Ina YES
Code FBC2017rFP12014
CSI.
TC 0.50
BC 0.39
WB 0.23
Matrix-S
DEFL.
VertILL)
Vert(CT)
HOR(CT)
in (loc) Vde0 Lid
Na - n/a 999
n1a - n/a 999
0.00 7 rda n/a
PLATES GRIP
MT20 2441190
Weight: 881to FT=0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 600 GC punins,
BOT CHORD 2x4 SP No.3
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oC bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 2000.
(to)- Max Hoyt 1=151(LC8)
Max Uplift All uplift 1001b or less at joint(s) 7, 11, 10, 8
Max Grav All reactions 2501b or less at joint(s) 1, 7 except 11=393(LC
1). 10=542(LC 13),
9=540(LC 13),
8=488(LC 14)
FORCES. (lb) -Max. CompJMax.Ten. -All forces 250(lb) or less except when shown.
WEBS 2-11-3091111, 3-10=383/138, 4-9=324/45, 5-8=315/97
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; B=4511; L=24ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MAIMS (directional); Cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water paneling.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) Gable requires Continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load noncencurrenl with any other live loads.
7)' This truss has been designed for a live load of 20.Ops1 on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom Chord and any other members, with BCDL = MOSEL
8) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 1001b uplift at joint(s) 7, 11, 10. 8.
Thomas A. Albani PE No.39360
MITek USA, Ine. FL Cart 6634
0904 Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING - verity design Parameters and READ NOTES ON THIS AND INCLUDED MREK REFERENCE PAGE 111II-04ILev.1RWR015 BEFORE USE.
'
Design vale!for use 0*won MTek®connectors. We Lezlgn is eased! Only upon parameters Mown, and is on an IMividual building MG,pigia ,not
a truss system. Before use, the evil designermust very gw eppMeabNy of design parameters and properly InwryaMe This deep Into the overall
obldingdeeign. Bmdng lMlessed late prevent begWro ofmdMdual Wse web andfor word members only.Add'dionaltemporayandpemlanentbncMg
MOW
Is akvays required far slabildy and to prevent w0apse web possible personal Injury end property defrosts. Forgeneral guldan a regarding me
fabriwuon.storage.detivery, erection and bracing ofeusxs and Uues quads. we ANSU711 Ouaay Cdred4, DSB49 and SCSI Bullding Component
6904 Parke East BNd.
Sabylnrmmmlon awlabkfrom TNes Plate InMUe.219N.Lee Bbeel.Buse31ZMl ndM.VA22314.
Tairya. FL 36810
Job
Truss
Truss Type
pry
Ply
Walsh Residence
T78074380
J38351
OA
Valley
1
t
Job Reference (optional)
l«-++ram a4vu sea r R ZDla MueRmausmes,Inc. uesepiuua:z4:ua[ups rages
ID:INmub4goEcpdh37zljasEOyjN73-D3Kx8YepcO2la2cdr8pBi08L86Ma4P1 s7pdJUbyf4Dv
86A 11543 20-0-0
88.8 I 2-1M I 8EA
Scale: 318-=1'
4x4 =
44 =
3 11 12 4
3x4 G 10 9 8 7 3.4 J
1.4 II 1x4 II led II 1.4 II
LOADING (psU
TCLL 20.0
TCDL 20.0
BCLL 0.0 •
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Inv YES
Code FBC2017/rP12014
CSI.
TC 0.48
BC 0.25
WB 0.09
Matrix-S
DEFL.
Veri(LL)
Vert(CT)
Horz(CT)
in (loc) gde8 L/d
We - n/a 999
n/a - r/a 999
0.00 6 n/a We
PLATES
MT20
Weight. 761b
GRIP
244/190
FT=0%
LUMBER-
BRACING -
TOP CHORD 20 SP NITS
TOP CHORD
Structural wood sheathing directly applied or 6-0.0 oo purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 cc bracing.
WEBS 2x4 SP No.3
OTHERS 20 SP No.3
REACTIONS. All bearings 20-0-0.
(Ib) - Max Horz 1=100(LC 7)
Max Uplift All uplift 100 Ito or less at joints) 7, 10
Max Grav All reactions 2501b or less at joint(s) 1, 6 except 7=478(LC 14),
10=478(LC 13),
9=381(LC 13),
8=365(LC 14)
FORCES. (lb) - Max. ComplMax. Ten. -All forces 250 (Ib) or less except when shown.
WEBS 5.7=-383/139, 2-10=383/139, 3.9=276/36, 4-8=276/36
NOTES-
1) Unbalanced mat live loads have been Considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf; BCDL-6.0psf; h=18ft; B=451t; L=2411; eave=4ft; Cat.
II; ESP B; Encl., GCpi=0.18; MWFRS (directions]); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) Gable requires Continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads.
7)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3 6-0 tall by 2-0-0 wide
will rd between the bottom chord and any other members, with BCDL = 10.Opsf.
8) Provide mechanical Connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 10.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
69U Parke East Blvd. Tempe FL 33610
Data:
September 10,2019
®WARNING Venlydesignparamelars endREAD NOTES ONTHISAND INCLUDED MITER REFERENCE PACE MIIJ473 rev. 1010sa is BEFORE USE.
Design valid OR use only Win MTeM comleLlom. ¶119 de5lgn Is WSM any Upon parameters shown. and Is for an IMIYtdual building ampanent, not
a for pass system. Bee use, the baking designer must vent' the appikabiy of design parameters and propexy Incorporate this deep Into the overall
bulidingdesign. Breoing mWated is to prevent beading of adMdual truss web and/or NON members only. Addelonalmmpomryaelpermanembra0ing
MiTek-
8 always; required far stabidy and to prevent collapse with pOWDIe persaal injuyand property damage. ForgenealguManc. regaming on.
fatmemon, slarege, deuvey,eretion and bradn Of WWW and was systems.see ANSVrpst Quality Cigeda, DS949 and 80Sl Building Component
6904 Parke East Bled.
Sororylnformarlon available hdm Truss Plate inWW%218 N. Lee Street, Suite S12 Alexandda, VA22314.
Tampa, FL 36610
e
Job
mss
Tmss Type
pty
Ply
Walsh Residence
T18074381
J38351
OB
Valley
1
1
Job Reference o tional
3x4 i
LOADING (psf)
TCLL 20.0
TCDL 20.0
BCLL 0.0
BCDL 10.0
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 20 SP No.3
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
a.Z4U a Jul 14 1Ul9 MI I eK mausme5, Inc. I ue Sep lU U9R4:Ub ZUI V Page 1
ID:INmub4goEcpdh37zljasEOyjN73.hGuJLufSNiAtCIBpP9KDEchPBMCpr OMTMs01yf4Du
Scale -1:33.7
4x4 1.4 II 2x4 I
B2x4 II
SPACING-
2-0-0
CSI.
DEFL.
in (loc) I/deg L/d
PLATES GRIP
Plate Grip DOL
1.25
TC 0.91
Vert(LL)
n/a - n1a 999
MT20 244/190
Lumber DOL
1.25
BC 0.67
Vert(CT)
n/a - rda 999
Rep Stress Ina
YES
WB 0.18
Horz(CT)
0.00 6 rda n/a
Code FBC2017/TPI2014
Matrix-S
Weight: 79 lb FT-0%
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc puriins,
except end verticals.
BOTCHORD
Rigid ceiling directly applied or 10*-0oc bracing.
REACTIONS. All bearings 20-0-0.
(lb)- Max Horz 1=151(LC8)
Max Upl'm All uplift 100 Its or less at joint(s) 6, 9, 8, 7
Max Grav All reactions 250]bar less at joinl(s) 1 except 6=282(LC 13), 9=456(LC 1). 8=513(LC 13), 7=780(LC
14)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
WEBS 2-9=373/136, 3-8=-352/109, 4-7=525/169
NOTES.
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=9.Ops8 BCDL=6.Opsq h=18ft; B=45ft; L=241t; eave=oft; Cm.
II; Exp S; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right "posed: Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water pending.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads:
6) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 Wide
will fit between the bottom chord and any other members, with BCDL = I O.Opsf.
7) Provide mechanical Connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 9, 8, 7,
Thomas A Albeni PE No.39380
MiTek USA, Inc FL Cad 6634
6904 Parke East Blvd. Tampa FL 33610
Bale:
September 10,2019
®WARNING- Venly design paramelers and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE M14I473 ree. IMM015 BEFORE USE.
Design vaod for use only warn MTek®veraxApn. TNA deelgn IS based only upon Wramaters shown, and Is loran Inevdiew bu irg component, neat
awaas syflam. Before use." building designer mull ddWhe ap,kabiliryol na, paramelers and pre,M lncn,ava. gab design lntome odlea
bulleingdasign. BmcinglMirsletl isle prednt buckling of in4lWduai Wss web anNw NON member onry. AddWonalterWoraryandcermanemdacrig
WOW
always required for slal and to passage collapse with possible persan d Iqury and properly damage. For general guldance n,,"Ing tha
febrlcaron, atomga deevery, erection and bradrrg of Uussas and Wsa systems,see ANSUTP110uaro,Orleans, DSB-99 and SCSI BiAling Camponene
6904 Pare, East Bid.
Safterafionmion avaiWNefrem Truss RMelnsl8ule,218N.Les61ree46u9e312Alesandr$VA22314.
Tampa. FL 36610
Jab
Tmss
TypeOty
Ply
Walsh ResistanceT78074382
TVaw11'e`y
3B351
V24
1
1
Job Reference (optional)
"... •^... •• ___.••-++�+•+ n14us4Ul 14 avid mllea mausmes, Inn I ue JeplUUV:Z4:WZUIV Pagel
IO:INmub goEopdh37zliasEOyjN73-9SShYE/4801kptm?ztrfnpDhgw2DYIP96760YTyf4Dt
BEE 15.5E 24-M
BEE 6-11.0 I BEE I
Stale-1:38.5
44 = U4 II 4x4 -
3 14 4 15 5
3x4 i 13 12 11 10 9 8 3x4 C
1.4 It 1.4 II 1.4 II 1.4 II 3x4 = lx4 II
LOADING (psf)
TCLL 20.0
TCDL 20.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Inar YES
Code FBC20177TPI2014
CSI.
TC 0.47
SC 0.24
WB 0.10
Matrix-
DEFL.
Ved(LL)
Vert(CT)
Horz(CT)
in (loc) Octet Ud
rda - n/a 999
nla - n1a 999
0.00 7 n1a n/a
PLATES GRIP
MT20 2441190
Weight: 93 lb FT=0%
LUMBER.
BRACING.
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOTCHORD 2x4 SP No.3
BOTCHORD
Rigid ceiling directly applied or 10-0-0oc bracing.
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. All bearings 24-D-0.
(lb)- Max Horz 1=100(LC 7)
Max Uplift All uplift 100 Ib or less at joint(s) 11, 8,13
Max Grav All reactions 250 lb or less at joints) 1, 7 except 11=433(LC
19). 8=475(LC 14),
13=475(LC 13).
10=392(LC 14), 12=408(LC 13)
FORCES. (lb) - Max. CompJMax. Ten. -All forces 250 (Ib) or less except when shown.
WEBS 4-11=301/67, 6-8=382/13B, 2-13=382/138, 5-10=282/44, 3-12=282/44
NOTES-
1) Unbalanced roof live loads have been Considered for this design.
2) W nd: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=9.OpsF BCDL=6.OpsY hot Bit; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp B; Encl., GCpl=0.18; MWFRS (directional); camblever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its Center.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL=10.Opsf.
8) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 1001b uplift at joints) 11, 8, 13.
Thomas A. Albani PE No.39380
MiTek USA, Ina FL Cart 6634
6904 Paden East Blvd. Tempo FL 33610
Date:
September 10,2019
®WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUOEDMITEK REFERENCE PAGE MII4473rev. I0/03Yle15 BEFORE USE.
Design vdW kr use only was MTeM conneaots. This design is based only upon psemeten shown, and la for an ox[Moua] buaditg cnmponem, rnt
almaaaystem.Befomuee,mebW hgdOaignermaat Yedtymeappecabietyof&e gnp mmmersardprepedy Ncmpo eNhdesignimotbom nee
buildingdosign. Bm guMic Mistopmae bus gof NdMduallmsswebe Cal ordmembenonM. ALdNonaltempararyaMpetmanembracing
�1Te1.'
1C
Is elwaya requlrad tar atabllty and to prevemwAapse wlm pouible personal lOjuryend propeMdamaAa. Forganerelgddanceregarditgme
Wdtadon, storage. delivery, erection and bracing minuses and Was systems, see ANSM11Quality Citeds, DS9E9 and SCSI Building Component
fi50a Parke East SW.
East S
Sarelylo ormation av "ble bom Tmss Mme lnMAu a.218 N. Lee Sireer, Su4e 312 Alexandda. VA=14.
Tanya, FL
Job toss
Truss Type
Oty
Ply
Walsh Residence
T18074383
J38351 V28
Valley
1
1
Job Reference o tional
-__• •• • •-••••-. • ••-_-� u s um w m ro mn arc mausmes, me ma aep ro ua:zR:ur <ma rage 1
ID:INmub4goEcpdh37zljasEOyjN73deO3magivJObROLC WaMuKlmmgKJNHkbJpnmSwyf4Ds
8- 8 155-8 2&0.0
I eae I 10.H-0 I 841A �
Scale=1:45.1
4x4 = 1.4 II 4x4 =
3 14 4 15 5
3x4 G 13 12 11 10 9 8 3x4 C
1x4 It 1x4 II 1x4 II 3x4 = 1x4 II
1x4 II
LOADING (psf)
TOLL 20.0
TCDL 20.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress lncr YES
Code FBC2017rrP12014
CSL
TC 0.83
BC 0.57
WB 0.17
Matrix-S
DEFL,
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
0.00
(too) VdeD Lid
- n1a 999
- n1a 999
7 File n/a
PLATES GRIP
MT20 244/190
Weight: 105 In FT=0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or fi-0-0 Be purling.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. All bearings 28-0.0.
(Ile) - Max Ho¢ 1=104(1_C 6)
Max Uplift All uplift 100 lb or less at jolm(s) 11. S. 13
Max Grav All reactions 250 lb or less aljoint(s) 1, 7 except 11=729(LC 13),
8=459(LC 18).
13=359(LC 17),
12=515(LC 13), 10=499(LC 14)
FORCES. (Ib) - Max. CompiMax. Ten. -All forces 250 (lb) or less except when shown.
WEBS 4-11=5021122, 6-8=-379/136, 2-13=379/136, 3.12=J44/60, 5.10=344160
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wmd: ASCE 7-10; Vuh=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf, BCDL=6.Opsf, h=18ft; B=45ft; L=28ft; eave=4ft; Cat.
11; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and fight exposed; Lumber DOL=1.60 plate grip OOL=1.60
3) Provide adequate drainage to prevent water pending.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) Gable requires continuous bottom chord bearing.
6) This buss has been designed for a 10.0 par bottom chord live load noncencurrent with any other live loads.
7) 'This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL=10.0psf.
8) Provide mechanical Connection (by others) of truss to bearing plate Capable of withstanding 1001b uplift at joint(s) 11, 8, 13.
Thomas A. Alban! PE No.39390
MiTOk USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING-Vedly design paramelere and REAP NOTES ON THIS AND INCLUDED MITEx REFERENCE PAGE MU-7470 rev. 101OW2015 BEFORE USE.
De5{aavdia bt u9e Onh' WW1 MIT¢k® WMlelanl. THIS ae9lgn i911a9ed 01,1/ Ygon Oaamelel5 61,OW(I, AIE IS rW do egiV.dael aI11Nng LOmpOnMl. nO1
��®®
aeussayesignB ate andbachoad rameeignee pnpeMlncaryonmorary
A1911'vaothaowrall
ranuse.aleed latepresentof inhaeia[Vuss web pemunent aradng
weaury
Awareesgn.arering inalcand is toprewnlisinewN
MiTek'
ssiNe pW99
Is en propedemaene.For general gemponryanO
engtopnwmmeepuwMpoand",ersonalins. andpnpe Porgenenlga,DSEregarding me
f.bdoeyarequindr0rsraainly
ANSInnge.
rdadl1EOe,9(OR99B.deN•ery�enGlOa MdanCingIN W95es and WSS ayb10m9.5e2 ANSUIP1l quality Cdnda, eSad9 and SCSI Building Component
Sarerylnfoee
6904 Parke East and.
on avabblenon Tn,s Plateln,MN.,21SN.Leeg M,sane312Alexandria,VA2al4.
Taw.. FL 36610
Job Truss
Truss Type
Oty
Ply
Walsh Residence
T18074384
J38351 ZCJ1
Jack -Open
17
1
Job Reference (optional)
o.wua4m wammu en niamurca, mu ma aep ioov.c¢Icmro rage I
Scale =1:7.8
3x3 =
LOADING (pst)
SPACING- 240-0
CSI.
DEFL.
in
(]cc)
War
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.25
Vert(LL)
0.00
7
-999
240
MT20 244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.08
Vert(CT)
0.00
7
o999
180
BCLL 0.0 '
Rep Stress Inv YES
WE 0.00
Horz(CT)
-0.00
3
n/a
nla
SCOL 10.0
Code FBC20177rP12014
matrix -NIP
Weight: 5lb FT=0%
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 3=-6/Mechanical,2=230/0-8-0,4=-25/Mechanical
Max Horz 2=56(LC 8)
Max Uplift 3=6(1_C 1), 2=-92(LC 8), 4=25(LC 1)
Max Grew 3=9(LC 9), 2=230(LC 1), 4=22(LC 8)
FORCES. (lb) - Max. CompJMax. Ten. -All farces 250 (Ib) or less except when shown.
BRACING -
TOP CHORD Structural mod sheathing directly applied or 0-11-4 cc purtins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing.
NOTES-
1) Wind: ASCE 7-10; Vu8=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; B=45111; L=24111; eave=4ft; Cal
II; Exp B; Encl., GCpl=0.18; MWFRS (I irec0onal); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or tough handling and erection Conditions. It is
the responsibility of the fabricator to Increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about Its center.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 10016 uplift at joints) 3, 2, 4.
Thomas A Alban! PE No.39360
MITek USA, Inc. FL Cert 0634
6904 Parka East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING. Verily design parameters and READ NOTES ON less AND INCLUDED MITEK REFERENCE PAGE MY7473 rev. 10AU1015 BEFORE USE.
'
Design valW Cruse onyweh MRex®Conneulors. TNsdevgn is based and/ uponpaamHers shown. and Is for an IndMdud IgAding Component not
a truss system. Before use. the building designer mud veriytne appgcal of dedgn parameters and property inotapgale this design We me overall
bulCingdesign. Bacing Indicated is to present IsiUdng MindiWdual truss Eb andlm chord members only. A4dtianaltemporaryardionganeNbacig
MiTek'
Is alvaya required for dabilily and to prevent Collapse with possible personal Injury and papeAy, damage. ForgenealguWencere,ocingme
fabrication, storage. delivery, eredbn and bracing MWsses and Was sydems,we ANSUIPI10uests Creech, DSBd9 and SCSI Building Component
Was Parka Seat Was.
SaCylrMrmaaon aa.&blefrom Truss Ptde lndAute,2la N. Lse Wee. Suda3lZAIUdddM,VA2Z314.
Tampa, FL 36610
Job Truss
buss Type
OtY
Ply=caT18074385
J38351 ZCJIA
Jack-0pen
1
(optional
uum, rr. r,oiw, r�.rro.o 1,5.24usJU1142U19MIleKlnoustnes,Inc. TUe Sepl003:24:132019 Pagel
ID: INmub4goEcpdh37zljasEOyjN73SoNKOtlRU9A19xoLVTIZIO ?kULhUjBCIIH IZyf4Dm
0-11-0
0-11-0
a
3x3 =
Scale=11.8
LOADING (psf)
SPACING. 2-"
CS1.
DEFL, in
(hoc) UdeO Lrd
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.02
Ve art -0.00
6 ,999 240
MT20 244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.02
Vert(CT) -0.00
6 >999 180
SCLL 0.0 '
Rep Stress Inci YES
WB 0.00
Horz(CT) 0.00
1 We n/a
BCDL 10.0
Code FBC20177rP12014
Matrix -MP
Weight: 3lb FT=0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 0-11-4 oc pudins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid Calling directly applied or 10-0-0 Do bracing.
REACTIONS. (lb/size) 1=46/0-8-0, 2=32/Merhaniml, 3=15/Mechanical
Max Horz 1=18(LC 8)
Max Uplift 2=12(LC 8)
Max Grav 1=46(LC 1), 2=33(LC 13), 3=19(LC 3)
FORCES. (lb) - Max. Comp.IMax. Ten. -All forces 250 (Ib) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vuh=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsh BCDL=6.Opsf, h=18ft; B=45ft; L=241t; eave=4tt; Cat.
II; Ex a B; Encl.. GCpi=0.18; MWFRS (directional); Cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection Conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about is center.
'4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss Connections.
7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 10011, uplift atjoint(s) 2.
Thome. A. Albani PE No.39388
MiTsk USA, Ins. FL Car 6634
0964 Parka East Blvd. Tampa FL 33610
Damn
September 10,2019
®WARNING- Venly design parameters and READ NOTES ON THIS AND INCWDED MITER REFERENCE PAGE 014473 rev. IOM312015 BEFORE USE.
aaaaaa
Design valid for use city earth MTe rl, connectors. This design Is based ony upon Indonesia shown, and Is for an indiNdual buJtlirp component not
��'
a Truss system. Before use, the buiding designer must verify the applirabirdy adesign pmm aelers and propedy incorporate m Ina design Into e overall
buidingdesign.. BmkgindicetedlstopmmtbUa gaindMdualWssweba vOordmembenmly. AAdBionaltempora andpennmembmdng
MiTek'
is always required for stability y and to preveCollapse son, possible personal Inlu yard property damage. For general guidx ae regarding the
fabnOgon, aomge, delivery, ere n and bmdng a Wsms and buss systems, see ANSgTP11 Coardy Closing, DS1aa9 and SCSI Building Component
6904 Parka East BM,
ion"trddermahn a bblehem Tmss Rate In9h e.218N.Leesbe0,Suae312,Alexandra.VAM14.
Tampa. FL 3e61D
Job
russ
Truss Type
Oty
Ply
Walsh Residence
T18074386
J38351
ZCJ3
Jack -Open
13
1
Job Reference (optional)
mean coast truss, FL Pierce, FL seaao 8,240 s Jul 142019 Mtrek Industries, Inc. Tue Sep1009:24:132019 Pagel
ID:INmub4goEcpdh37zljasEOyjN73SoNKOdrrU9Al9xoLtrTIZIOxPkSG UIBCjlHIZyf4Dm
-0-0 2-114
d0 2-114
�i
3x3 =
Scale=1:12.9
2-114
LOADING (pst)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Udell L/d
PLATES GRIP
TOLL 20.0
Plate Grip DOL 1.25
TC 0.25
Vert(LL) -0.00
4-7 >999 240
MT20 2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.13
Vert(CT) -0.01
4-7 >999 180
BCLL 0.0
Rep Stress In1r YES
WB 0.00
HGrz(CT) 0.00
2 n/a me
BCDL 10.0
Code FBC2017rrP12014
Matrix -MP
Weight: 12 Is FT=0
LUMBER.
BRACING -
TOP CHORD 2x4 SP N0.3
TOP CHORD
Structural wood sheathing directly applied or 2-11-4 Do purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-M oc bracing.
REACTIONS. (lb/sae) 3=90/Mechanici 2=275/0-8-0, 4=29/Mechanical
Max Horn 2=93(LC 8)
Max Uplift 3=29(1-C 8), 2=-61(LC 8)
Max Grav 3=93(LC 13), 2=275(LC 1), 4=52(LC 3)
FORCES. (III) - Max. Comp.fMax. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vuh=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf, BCDL=6.Opsf; h=18ft; B=45ft; L=24ft; eave=oft; Cat.
II; Exist B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and Tight exposed; Lumber DOL=1.60 plate gnp DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection Conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its Center.
4) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss Connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) 3, 2.
Thomas A Alban! PE No.33380
MiTOR USA, Inc. FL Cart 8634
9904 Parks East Blvd. Tampa FL 33610
Date:
September 10,2019
® WARNING -Venlydeslgn parameters antl READ NOTES ON MIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 re¢ 10,03/2015 BEFORE USE.
Design wild for use only with MlTak® connectors. This design is based only upon parameters shown, and is for an Individual bugding component not
a Loss system. Before use, me building desut ner mustventy Me appgrebiky of design parameters and popery, incorporate mis design Stotbe overall
building design.. Smaingirdicated is to preventbudJg of ninviral Loss web andlorchodmembernonly.Additionaltemporeryandpennanembredng
MiTek'
is always required for debikly and to p..M.ff psewdh posuble permml Inluryand pmpedydamage. For general guidance regadin, Ne
fabdmaon, Storage. delivery. erection and braung ofLoeses mdi MISS System, see ANSI/rPlf Quality Cdreda, DS"9 and SCSI Bulling Component
6904 Parke East BIM.
Sefeylnfarmuflon avagableham Truss PlatalnsMde,218N.Le Mmd,Sure3lZAlexandria,VAMi4. .
Tampa, FL 36610
Job I
TM
Truss Type
Qty
Ply
Walsh Residence
T18074387
J38351
J
ZCJ3A
JaGc-0pen
1
i
_ _
_
Job Reference D banal
ua aep m ua:<v:Iv <. a rage I
ID:INmub4goEcpdh37zljasEOyjN73-w?xjEzm5FTIcn5NYRY X6VZ6K8nDQx LQN2rrOyf4Dl
Scale = 1:12 9
3x3
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
Udell
Uri
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.24
Vert(LL)
-0.00
3-6
>999
240
MT20 244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.17
Vert(CT)
-0.01
3-6
>999
180
BCLL 0.0 '
Rep Stress Ina YES
WB 0.00
Horz(CT)
0.00
1
n/a
Na
BCDL 10.0
Code FBC20177TPI2014
Matnx-MP
Weight: 9lb FT=0%
LUMBER.
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 1=144/0-e-0, 2=102/Mechaniw1, 3=42/Mechanical
Max Hors 1=55(LC8)
Max Uplift 2-36(LC 8)
Max Great 1=144(LC 1). 2=104(LC 13), 3=58(LC 3)
FORCES. (lb) -Max. CompdMax. Ten. -All forces 250 (Ib) or less except when shown.
BRACING -
TOP CHORD Structural wood sheathing directly applied or2-11-4 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES.
1) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp B; Encl.. GCpi=0.18; MWFRS (directional); cantilever left and fight exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 par bottom chord live load nonconcument with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Will fit between the bottom chord and any other members.
6) Refer to girders) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) 2.
Thomas A. Albeni PE N%39380
MiTek USA; Inc. FL Cart 6634
6906 Pales East Blvd. Tampa FL 336f0
Date:
September 10,2019
®WARNING - Vwflydesi9a Panmelero and READ NOTES ON THISAND INCLUDED MITEN REFERENCE PAGE MI47473iev. 1OMWO15 BEFORE USE.
Designvalidforuseonywah MI70W nne M.Thudesignisbasedmn uponparametersshown,and IsfmanIMiNdualbuUdil,wmponem,nth
a truss system. Befbn use, me building dead ner must very the ap,rodbirlly of deep parameters and properly mco,and. hits design Into Me owned
burdingdemgn. Bracing Indicated is io prarxm Welding of individual truss web nation MOM members anyrynn . AdeConaltemporaandpeanembrach,
N��-A���YYY
MiTek'
tv always Normal for stability and to pMwmt soaapse with possible personal Injuryand propmty damage. Forgenenl guidance regarding Ns
fabriratian,9oage, detwery, emotion and brain, mousses and truss systems, we ANSI?P/I Quality Criteria, DSBd9 and BCSI Building Component
6904 Parke East BIM.
Saretylnformation aWa blefmm Truss Plmeln5bme.218N.Lee6 0,Suke31Z,A andh,VA22314.
Tampa FL WIG
Job '
msa
Truss Type
City
Ply
Walsh Residence
T78074388
J38351
CJS
Jack -Open
9
1
Job Reference o tional
East Coast Truss, YL Pierce, l'L J4946
B.24U S Jul 14 ZU19 MI I ek IndUsales, InC. I U9 6ep 1U U9:Z411b 2Ul V
Scale = 1:17S
3Kt =
4-
4-1141-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(toe) Vdefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.71
Ven(LL) 0.06
4-7 >999 240
MT20 2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.47
Vert(CT) -0.07
4-7 >851 180
BCLL 0.0
Rep Stress Ina YES
WB 0.00
Honi 0.01
2 n/a nla
BCDL 10.0
Code FBC20177TPI2014
Matnx-MP
Weight: IS lb FT=O%
LUMBER- -'
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or4-11-4 oc pudins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=167/Mechanical,2=365/04e-0,4=63/Mechanical
Max Horz 2=132(LC 8)
Max Uplift 3=-65(LC 8), 2=-121(LC 8), 4�41(LC 8)
Max Grav 3=167(LC 1), 2=365(LC 1). 4=95(LC 3)
FORCES. (lb) - Max. Comp.lMax. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; 8=45fl; L=24ft; eave=4ft; Cat
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate grip
DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about 0s Center. r
4) This truss has been designed for a 10.0 pelf bottom chard live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live lead of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will 5t between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss Connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) 3, 4 except (jt=lb)
2=121.
Thomas A Albani PE No.39330
MiTek USA, Inc. FL Cart 6634
69M Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MREK REFERENCE PAGE MI47473 rev. 10/03R015 BEFORE USE.
*e
Design Valid for use only wM Ilmek® cwneaors. This design is based only Upon parameters mean. and is for an IndiWdual building component. not
a truss system. Before use, the bulling designer must vent' Me applicability of desire parameters and Papally scarporee MS design We Vie menial
-•Y�•
buildingdesfgn. Brecing"vMiatadist0 premmbuWingollntlMtlualimssweb anNarchoN members wig. Aaktmattengwraryandpermanembracing
MtTeke
Is always required of stabi ly and to premm window wM possible personal injury and pmpeny damage. Fargeneml gnitlawe regartling Me
fabdraion, engage.delivery, season and bracLg ofbusses and truss systems, see ANSUTPH Duality Ceffeda, DSBAa and BCS1 Building Component
6904 Parke East Bled.
Sarmyrnforfeagon amaeblefmm Truss Platelns e,218N.Lee SVaet.Sude312,Alexandde,VAU314.
Tampa, FL 36610
Truss
Truss Type
Qty
Ply
Walsh Residence
IJob
]Jack
T18074389
J38351
ZCJSA
-Open
1
1
Job Reference (optional)
Us =
41 4-0
tl24U S Jul l4 2U19 MI IeM M0UVnes, MC. I ue Sep 10 09:24:16 2019 Pagel
ID:INmub4goEcpdh37zljasE0yjN73sN3TRnLn4YKOPXwYzl?BweKcyNGurSduhXxvuyf4Dj
Scale =1:17S
LOADING (psf)
SPACING. 2-0-0
CSI.
DEFL. in
floc) Vde0 L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.77
Vert(LL) -0.03
3-6 >999 240
MT20 2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.52
Vert(CT) -0.08
3-6 >774 180
BCLL 0.0 '
Rep Stress Ina YES
WE 0.00
Ha, CT) 0.01
1 rda n1a
BCDL 10.0
Code FSC20171TPI2014
Mabbr-MP
Weight: 161b FT=0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or4-11-4 oc puffins.
BOT CHORD 20 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=244/0-6-0, 2=173/Mechanical, 3=70/Mechanical
Max Horz 1=93(LC 8)
Max Uplift 2=-60(LC 8)
Max Grav 1=244(LC 1), 2=176(LC 13), 3=99(LC 3)
FORCES. (M) - Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shaven.
NOTES.
1) Wind: ASCE 7-10; Vult=160mph (3-sewnd gust) Vasd=124mph; TCDL=9.0psf; BCDL=6.Opsf; h=18ft; 13=4511; L=24ft; eave=oft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and fight exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom chard live load nonwncurrent with any other live loads.
5) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 Wide
will Td between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 He uplift at joint(s) 2.
Thomas A. Albani PE No.39380
MITBk USA, Inc FL Can 6834
6904 Parke East She. Tampa FL 33610
Date:
September 10,2019
®WARNING - Vard'y design paaamerers and READ NOTES ON THIS AND INCLUDED MITEX REFERENCE PAGE 114II-0413 rev, 10/033015 BEFORE USE.
Design valid for use only with MITEM connectors. This design Is based only upon pammaters shown. and Is for an individual bantling component, not
a Mass syeem. Serve use, the Waint designer must vent' me appekabilfty of design parameters and property incorporate Nis design Into Me overall
��Y�•
tWiingdesign. BracingiWicatedlstopr MbaUngoruldMdual WSSWeb Md UOMmembeMOnty. AddlonaltempomryaMpermanentbradng
MiTek'
Is axvays required for Stability and to prevent collapse sigh possible persoral injuyand property damage. Forgeneral guidamur agarding the
fabrication,stomge.deWey,emr onmdbradl dWssesaMWsssyeems,we ANSUTPII Qualify COMda, DS8 9 and BCS1 Building Component
Se/e rInformadon available from Truss Plea Institute. 218 N. Lee Street, Suite 312, Aletendria, VA22314.
6904 Parke East Blvd.
Tampa. FL 36610
Job
sa
Truss Type
Qty
Ply
Walsh Residence
[CJ7A
T18074390
J38351
Jack -Open
1
1
Job Reference (optional)
3x4 =
7-0
d24U a Jul 14 2Ula MI I eK Industries, Inc. I ue Sep 1U U324:16 201a PD99 1
ID:INmub4goEcpdh37zljasEOyjN73-sN3TNnLn4YKOPXwYzl?BweGIyLAurSduhxxvuyf4Dj
3
Scale =1:23.3
LOADING (psi)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.98
Vert(LL) 0.12
3-6 -672 240
MT20 244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.65
Vert(CT) -0.29
3-6 >289 180
BCLL 0.0
Rep Stress Ina YES
WB 0.00
Hom(CT) 0.04
1 No Na
BCDL 10.0
Code FBC2017rTPI2014
Matrbc-MP
Weight: 22111 FT=0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD 2x4 SP N0.2
BOT CHORD
Rigid ceiling directly applied or 10-0-0oc bracing.
REACTIONS. (III/Size) 1=34710-8-0, 2=248rMechanical, 3=99/Mechanical
Max Horz 1=132(LC 8)
Max Uplift 2=85(LC 8)
Max Grav 1=347(LC 1).2=251(LC 13), 3=141(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown
NOTES-
1) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=9.OpsY BCDL=6.Opsf, h=18ft; B=45D; L=2411; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Cantilever left and night exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to Increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurr ant with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100111 uplift at joint(s) 2.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Can 6034
6904 Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING -Verify design parameters and READ NOTES ON rills AND INCLUDED NJTEK REFERENCE PAGE MIIJ473 rev. IWO 4NO15 BEFORE USE.
seeree
**ee
Design vast forum only with KrekW cmmedooLMIte design is Casid Dory upon parameters shown, and is Wan individual bidding cemponme not
Mir
amass syVan Before use. the bulking designer must wanly Me apPgesbilityafdmign parameters and propmly Incorporate Ws designMothe overall
bulldingdesign. Bracing indicated is to prevent budidMg 4findluidual miss web andler chow members only. AddNlonal temporary antl permanent bracing
MiTek*
is always Moved for Duality and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, de6very, erection and trading of imams and Miss systems, see ANSVT lQuality Cdleda, DSB-ea end BCSl Building Component
6904 Parke Fast am.
SarelymformNon avaaatkfrom TrussRme IMMNute,21a N.Leaa e.6uae312Alexandda,VA22314.
Tampa, FL 361510
Job
Tmss
Tmss Type
Div
Ply
Walsh Residence
T18074391
J38351
ZEJ3
Jack -Open
7
1
_
Job Reference (optional)
r:asr x,oast I russ, n. ne , r, a i.
US =
U.24U S JU114 ZU19 MO eR indusm9S. IOC, rue SeD 10 U9:24:17 2019
Scale =1:13.1
3-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(Roc)
I/de0
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.25
VaI LL) -0.00
4.7
-999
240
MT20 2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.14
Vert(CT) -0.01
4-7
>999
180
BCLL 0.0 '
Rep Stress Ina YES
WB 0.00
Horz(CT) 0.00
2
Na
rda
BCDL 10.0
Code FBC20177rP12014
Matrix -MP
Weight 12 lb FT=0%
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 3=92/Mechanical,2=278/0.8-0,4=30/Mechanical
Max Horz 2=95(LC 8)
Max Uplift 3=30(1_C 8), 2=61(LC 8)
Max Gray 3=95(LC 13), 2=278(LC 1), 4=53(LC 3)
FORCES. (III) - Max. ComplMax. Ten. -All forces 250 (lb) or less except when shown.
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 Do bracing.
NOTES-
1) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf; BCDL-6.Opsf; h=18ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp B; Encl.. GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection Conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about Its center.
4) This truss has been designed for a 10.0 Pat bottom chard live load nonconcument with any other live loads.
5) ' This truss has been designed for a live load of 20.0pst on the bottom chord in all areas where a rectangle 3-S-0 tall by 2-0-0 wide
will lid between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss Connections.
7) Provide mechanical Connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2.
Thomas A. Aft ani PE No.39380
MiTek USA, Ine. FL Cert6634
6904 Palka East Blvd. Tampa FL 33010
Bate:
September 10,2019
®WARNING- VerllV design paramelen and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE Mll-7473ro. rNal/3OIS BEFORE USE.
DeslgovAid for use gnlywith MTeM c0nn0dors. This design is based only upon earzmelers Shoal, and is (gran bldividual Medg compomM, nth
ahuss "an Before use, the Watling designer must vent' Mo applicability of deSyn parameters and prepery boaWnde this design brio the overall
bwlEingdesign.Bear, in icaled is to prevent Wooing of bldividuel buss webandlu NON members only. AddvgnallamporayseepermanenibOsSag
MiTek'
isaiwayare9uhedfgrslabitityandWpre M.HO psewuhpossibleparsmallnjuryandpmpoMdamaga. Forgenemipldanwregardirg Ne
fabdoetion,storage, degvery,emoted and blaring ormnaves and Russ ayatams,see ANSVTPN Duality Cmeda, DS"9..d BCSI Bu11Rln9 Component
6904 Ranks East BM.
Serelylydonnatlun av ibbklimn Truss Nate Instauta,218N.LaeB 0,Suae312,Alexandria,VAM14.
Tampa. FL 36610
Job '
Truss
Truss Type
pry
Ply
Residence
T18074392
J38351
ZEJS
Jack -Open
10
1
�Walsh
Job Reference (optional)
east vast I russ, M. I•lerca, hl. 4494b 8.240 s Jul 14 2019 MiTek Industries, Inc. TUB Sep 10 09:24:18 2019 Page 1
IO:INmub goEcpdh37zijasEOyjN73bmBD4LpbJiol GjhJgO3TGLjgil4BMlywL702 nyf4Dh
I la-0
-0-0 I 54Y0 5-0-0 I
Scale=1:18.0
3x3 =
5-0-0
5-0-0
LOADING (psf)
SPACING- 2-0-0
CS].
DEFL. in
(loc) NdeB L/d
PLATES
GRIP
TOLL 20.0
Plate Grip DOL 1.25
TC 0.73
Vert(LL) -0.03
4-7 >999 240
MT20
244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.49
Vert(CT) -0.07
4-7 -817 180
BOLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.01
2 n/a We
BCDL 10.0
Code FBC2017rrP12014
Matnx-MP
Weight: 18 lb
FT=0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 5-0-0
ec pudins.
BOT CHORD 2x4 SIP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (fib/size) 3=169/Merhanical, 2=368/0-8-0, 4=64/Mechanical
Max Hom 2=133(LC 8)
Max Uplift 3=57(LC 8). 2=-54(LC 8)
Max Grev 3=172(LC 13), 2=368(LC 1), 4=96(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250(lb) or less except when shown.
NOTES.
1) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=9.Ops/; BCDL=6.Ops1; h=18ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to Increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 par bottom chord live load noncencument with any other live loads.
5) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-" wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2.
Thomas A Albert PE No.39380
MITek USA, Ina FL Cad 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September10,2019
®WARNING -Ven(y designp—e( andREAD NOTES ON WIS ANOINCLUOED MIrEK REFERENCE PAGEM114473rev. 10WR015 BEFORE USE.
Desgo valid forusetmlIr hMTeltAcolmeGon. This desk. is losses only upon parameters shown, and is foran movdual budONg compmwm.not
a miss system. Bases use, the bombing desgnermustvenly We applicable, otdesign parameters and properly monryorzle We design Otto the ovem6
buildingdesgn. Bmtlng MiWedistopmwe bur gMAdMdualtmsswebanWwNoNmembenony. AddMidetempa2ryandpermamidlemang
M!Tek'
m siesta nidulded for stablldy and to pmvent coaapse with posside personal Injury and property damage. For genena guldanoe regaining the
fabrication, storage.delivery emdbn and bmdng dmmzses and trues systems, see ANSg Pil Quaa"ry CWeda,DSB4i9and SCSI Bullding Component
East BIW.
Saretylydormerlon avaibbblmm TrussRneInsole,218N.Lees d.Bu0e312.nl drla,VA22314.
T
Tampa. 36610
ampaa,. FFIL
Job '
Truss
Truss Type
Oty
Ply
Walsh Residence
T18074393
J38351
ZEJSA
Jack -Open
1
1
Job Reference (optional)
I russ, rr. rlerte, eL 3M1
ass =
8.240 s Jul 14 2019 MTek Industries, Inc. Tue Sep 10 09:24:19 2019
Scale=1:18.0
Plate Offsets (X,Y)—
16:0-0-8,0-1-81
LOADING (psQ
SPACING- 2-M
CSI.
DEFL.
in
(loc)
I/deg
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.40
Veri(LL)
-0.02
6
>999
240
MT20
244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.70
Veri(CT)
-0.06
6
>999
180
BCLL 0.0
Rep Stress Ina YES
WB 0.00
Horz(CT)
0.02
5
n/a
n/a
BCDL 10.0
Code FBC2017/-rP12014
Matra -MR
Weight: 21 lb
FT=0%
LUMBER.
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 4=131/Mechanical, 2=382/0-8-0, 5-113/Mechanical
Max Hoa 2=133(LC 8)
Max Uplift 4=-36(LC 8), 2=-45(LC 8)
Max Grev 4=133(LC 13). 2=382(LC 1), 5=128(LC 3)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD 3-9=-276/0
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-0-0 cc puffins.
BOT CHORD Rigid ceiling directly applied or 10-" cc bracing.
NOTES-
1) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=9.0psY, BCDL=6.Opsf, h=18ft; B=4511; L=241t; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and fight exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection Conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will in between the bottom chord and any other members.
6) Referto girder(s) for truss to buss Connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2.
Thomas A. Allard PE No.39300
MTek USA, Inc. FL Cad 6034
6904 Parke East Blvd. Tampa FL 3XIII
Date:
September 10,2019
®WARNING. Verify deslgnp—lers antl READ NOTES ON THIS ANOINCCODED AVTEK REFERENCE PAGE MIIJIr3 rev. 10,035015 BEFORE USE.
Design vase! cruse o*wM WeWl connecers. "is design is eased only upon parameters Mown, and is fix an In0M0ual bugGlg compmrent, not
an. system. Before use, Use building deslgnermunvelifyche apperablay of design parameters and prepedy mcom0arate fhb design moth. overall
bwldingdesgn. BmGnginOiWedistoprevemeuUangorNdMdualWssweeandlcrchaNmemeersany AddGionaltemporsryeMpmmanemaacing
MiTek-
is alleys required for staelRy and to prevent Collapse with possible personal ibury and property damage. Far general gull once regamilg the
fabfltalloq Storage, deWery. ereGbn and bracing 0 trusses and Voss systems, we ANSM11 Cooley Crrlede, DS849 end BCSl Building Component
6904 Ranks East Blvd.
Sefelylnformedon mflablef Tmi RXelnOW9,218N.LeeMmd,5ke312,MemdA,VAM14.
Temp;R sesio
Job '
Coss
Truss Type
0ty
Ply
Walsh Residence
T18074394
J38351
ZEJ7
Jack -Open
53
7
Job Reference (optional)
East Coast Truss, Ft. Pierce, FL 34946
3x4 =
7-0S
7.
8.240 s Jul 14 2019 MiTek Industries, Inc. TUG Sep 1009:24:20 2019 Page 1
ID:INmub4goEcpdh37zljasEOyjN73-181 UOgsrJ31VOghnpSxLmpzt VgfSDpJV92fyf4Df
Scale=1:23.3
Plate Offsets (X,Y)—
(2:0-0-0,0-0-121
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(fee)
Vdeg
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.94
Vert(LL)
0.23
4-7
.355
240
MT20
2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.62
Vert(CT)
-0.27
4-7
>303
180
BCLL 0.0
Rep Stress Incr YES
WE 0.00
Horz(CT)
0.03
2
n/a
rda
BCDL 10.0
Code FBC20177TP12014
Matrix -MP
Weight: 24 lb
FT=O%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
REACTIONS. (lb/size) 3=243/Mechanical, 2=464/0-8-0, 4=94/1ilechanical
Max Horz 2=171(LC 8)
Max Uplift 3=94(LC 8). 2-145(LC 8), 4=60(LC 8)
Max Gmv 3=243(LC 1), 2=464(LC 1), 4=138(LC 3)
FORCES. (fig) - Max. Comp./Max. Ten. -All farces 250 (lb) Or less except when shown.
BRACING -
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; VuR=160mph (3-second gust) Vasd=124mph; TCDL=9.Ops/; BCDL=6.Opsf, h=18ft; B=45ft; L=24ft; eave=oft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Cantilever left and tight exposed; porch left exposed; Lumber DOL=1.60 plate grip
DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection condhions. It is
the responsibility of the fabricator to Increase plate sizes to amount for these factors.
3) Plates checked for a plus Or minus 0 degree rotation about fts center.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) a This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide
will fn between the bottom chord and any other members.
6) Referto girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift atjoint(s) 3,4 except gt=lb)
2=145.
Thomas A Albani PE No.39380
MiTek USA, Inc. FL Cort6034
6904 Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING Verily tlesign panmerers anJ READ NOTES ON THIS AND INCLUDED MITERREFERENCE PAGE M0.T471ra. IM31015 BEFORE USE.
Des'gnvalid for use orl weh MTeMoomodOes. This design is based only Mann parameters shown. and is foran 4MWIMd Murder, Comxxnen not
a buss system. MRM Use. No building designer must wrii applimblaly, of deep,summelersand properlyNmrporAe MIS design 4m the oWMH
buiNingdeslgn. Swing irdirated is to prevent Welting ofbd'Mdual MISS web GoWer Glom members any. Addaionaltemporay8odpermanentbradng
MiTek'
Is always required for stability and to prevent Collapse w4b possible personal injury and prepmty damage. For general guldarlce regaining me
fabric on,Mcmge,del Mere onmdbmdng Gtmssesand Wss VMems,me ANSUl Duality ensure, DSB49 and SCSI 8u11ding Component
6904 Parke East Blvd.
SaleylMonnaVon avaaableemn Tmss Rate InMAd 0,218N.Lea Street.Suee31ZAlexandria,VAU314.
Tampa, FL 36610
Job ' Truss
Truss Type
Oty
Ply
GO
T18074395
J38351 ZHJ4
Diagonal Hip Girder
2
=(olational)
east coast I russ, 1-1. Fierce, FL Meese 8.240 s Jul 14 2019 MTek Industries, Inc. Tue Sep 10 09:24:24 2019 Page 1
ID:INmub4goEc dh37z1)asEOyjN73dw1'VKOtMvYZO e8TOfA1VdczoBAA2mTRp)wTNB0yf4Db
-1-0P1D 42-3
1-10.10 I 423 I
Scale = 1:12E
ass = 2x3 II 5
42-3-3
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(too) Well L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.35
Vert(LL) 0.02
6-9 ,999 240
MT20 2441190
TCDL 20.0
Lumber DOL 1.25
BC 0.27
Vert(CT) 0.03
6-9 >999 180
BCLL 0.0 '
Rep Stress Ina NO
WB 0.00
Horz(CT) -0.01
2 n/a Na
BCDL 10.0
Code FBC20177rP12014
Matrix -MP
Weight: 18 lb FT=0%
LUMBER.
BRACING.
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 4-2-3 oc purl
BOT CHORD 2x4 SP No.2
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (Ib/size) 6=107/Mechanical, 2=260/0-10-15
Max Hom 2=94(LC 24)
Max Uplift 6=-49(LC 8), 2=i66(LC 8)
Max Grav 6=129(LC 28), 2=269(LC 28)
FORCES. (III) - Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCOL=9.Opsf, BCDL=6.Opsf h=18ft; B=45ft; L=24ft; eave=oft; Cat.
It; Exp B; Encl., GCpi=0.18; MWFRS (directional); can8lever left and tight exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to Increase plate sizes to account for these factors.
3) Plates checked for a plus Or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 Pat bottom chard live load noncencument with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girders) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) 6 except at=lb)
2=166.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 451b down and 119 111 up at
1-4-15, and 45 Ib down and 119 lb up at 14-15 on top chord, and 7lb doom and 53 Ib up at 1-4-15, and 7I6 down and 53 Ib up at
1-4-15 on bottom chard. The design/selection of such connection device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the face of the buss are noted as front (F) or back (8).
LOAD CASE(S) Standard
1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Inaease=1.25
Uniform Loads (ph)
Vert: 13=80, 34=40, 5-7=20
Concentrated Loads (lb)
Vert: 10=118(F=59, B=59) 11=73(F=37, B=37)
Thom, A Albert PE No.39380
MiTek USX Inc. FL Cert 6034
6904 Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING. Verity design paramahry and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MP7473 rcv. ION]20r5 BEFORE USE.
eausee
Design valid forgers ontyweh bLTekW connttlorf. Tnis design Is based ony upon parameters shown, and Is for an UMiNdual in ildhq component, not
atmss system. Before use, me building designer must writ' Neapplioablliyed.up parameters and property incorpo ede Me design into Maternal
bulldingdesign. BmWgilMioatedistopmwntWMingdMdMdual Wssweban&for ordmembm". P4dilional temporary elM pelmaneM bating
MiTek'
is always reputed for stailty and to prevent wines, wait possible personal injury ark property damage. For general guidance regaming Me
fabrication,storage, defvery,erection and bdadN of bussss and Was systems,see ANS11PIf energy, cdbde. DS849 and 6CS1 Building Component
6904 Parka East BIM.
Safofylnformmlon evagable hbm Truss Flats InaWme.21e N Lee SIreeL Suaa ]I2, Plexantlda, VA2231d.
Tampa, Fi M10
Job '
ms8
Truss Type
Oty
ply
Walsh Residence
T78074396
J38351
2HJ7
Diagonal Hip Girder
2
1
Jab Reference footion.11
rr. rierce, " on. 52408
Jul 14 2019 MTek Moustnes, Inc Tue Sep 10 09:24:252019 Page l
ID: INmuMgoEcpdh37zljasE0yjN73-566tVkuym2bnjfaMh62gvdyuaOSVlfyyaCwjtyf4Da
-1-10.10 F 4-1-7 7V
1.10-10 4-1-7 2-10.11
ass =
3.4 II
2x3 11
4-1-7 702 I
L1-7
Scale =1:19A
Plate Offsets (X,Y)-
f4:0-2-14 0-0-81
LOADING (par)
SPACING- 240
CSI.
DEFL.
in
(too)
Ude0
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.35
Vert(LL)
-0.03
8
>999
240
MT20 244/190
TCDL 20.0
Lumber DOL 1.25
BC 0.83
Vert(CT)
-0.05
9
>999
180
BCLL 0.0 '
Rep Stress Ina NO
WB 0.13
Horz(CT)
0.04
6
n/a
n1a
BCDL 10.0
Code FBC2017/rP12014
Matrix -MP
Weight: 34111 FT=0
LUMBER-
BRACING -
TOP CHORD
2x4 SP No.2
TOP CHORD
BOT CHORD
2x4 SP No.2'Except'
3-9: 2x4 SP No.3
BOT CHORD
WEBS
2x4 SP No.3
REACTIONS. All bearings Mechanical except (jt=length) 2=0-10A 5.
ill Max Horz 2=129(LC 8)
Max Uplift All uplift 100 Its or less at joint(s) 4,6 except 2=181(LC 8)
Max Grav All reactions 250 Ib or less at joinl(s) 4, 6, 5 except 2=379(LC 28)
FORCES. (III) - Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-330/43
BOT CHORD 2-9=82/254, 7-8=210/654
WEBS 3-7=671/216
Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oC bracing, Except:
6-0-0 oc bracing: 8-9.
NOTES-
1) Wind: ASCE 7-10: Vult=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf; BCDL=6.Opsf, h=18ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp B; End., GCpl=0.18; MWFRS (directions]); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2)As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about Its center.
4) This truss has been designed for a 10.0 par bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical Connection (by others) o1 truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) 4, 6 except (jt=lb)
2=181.
8) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support Concentrated load(s) 45111 down and 1191b up at
1-4-15, 45 Ib down and 119 IS up at 1-4-15, and 931b down and 57 Is up at 4-2-1 S. and 931b down and 571b up at 4-2-15 on top
chord, and 7Ib down and 53 Ito up at 14-15, and 7Ib down and 531E up at 1-4-15 on bottom chord. The designtselection of such
Connection device(s) is the responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the Buse are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pip
Vert: 1-4-80, 9-10-20. 7-8=20, 5-6=-20
Thomas A. Albeni PE No.39380
MiTek USA, Inc. FL Carl 6634
89U Parke East BNd. Tampa FL 3361D
Date:
September 10,2019
AWARNING -Ventydoaign parameters and READ NOTES ON DOS AND INCLUDED MUEx REFERENCE PAGE MI47473 rev, I&OW015 BEFORE USE.
Design ward for use anywim MTek® connemam. This design Is based only upon parameters shown, and is for an Individual Wgdlng component, not
assass
MY 21•
e Was Netem Before use, me beading designer must vedy me applicability of design parameters and MWg lnce anam, this deep Into me overall
buldingdesem. BmcmglMOd istoprewntWr gofddiVi altmnwftw&m hoNmem emwo r. Mdnbnaltemporaryandperromertemal
MiTek'
a atwayc reguked for Mangy andto prevem colmsewfth possible personal lnjuymd property damage. Forgenemlguidancelegardingme
fvericaton,storage,delivery, erection and bracing oftrusses and Wss systems,see ANSDTprl Bundy Cdteda, DSB89 and BCS1 Bulldfng Component
6904 parka East BIW.
SefeylnlormeNon avafteblehors TmssPWo Insure,216N.Lesa .9io31AAlexandria,VA=14.
Tampa FL assio
M
Job
was
Truss Type
Qly
Ply
Walsh Residence
T76074396
J38351
ZHJ7
Diagonal Hip Giber
2
1
Job Reference (optional)
Truss, Ft. Pierce, FL 34946
a LOAD CASE(S) Standard
Concentrated Loads (lb)
Vert: 13=118(F=59, B=59) 14-73(F=37, B=37)
8.240 s Jul 14 2019 MTek Industries. Inc. Tue Sep 10 09.24:25 2019 Page 2
ID:INmub4goEcpdh37zijasEOyjN73566tYku_grh2bnjfaMh62gVWueOSVtfyyaCwjtyf4De
®WARNING -Wray design parameters and READ NOTES ON THIS AND INCLUDED MITEN REFERENCE PAGE M0.7473 rev. IaN3QO1SBEFORE USE.
'
DeSignvalid for use onywllh MITAMOonnecton. Mis deslgn le based Dory upon parmelers shown, and IS for en Indimi bu8ditg camponenl not
Mal
a Uuss system Befae use, Use building designer must vedy8m epplirabi iiy of design parameters and pmpedy low,om a Nis design bdo the overall
bulldingdeslgn.Brc gi i=edistoPmwntNgWhMAduXMsswebmdlaUOMMembeMma e.7WdRbnalbmpomryaMpermaneNbacNg
NliTek'
Is atways required for stabiliy and to pmvem collapse with possible personal injury and properly damage. Forgenemdlguklanceegaiding Me
fabdradon,5omge,delivery,ereabnandbreaingoftmsses.M buss Intema.see ANSVTPll Dually Comdq DS849 and SCSI Bullion, Component
Soreylndingougn mmosole � TNSSPiataln=t 0,218NLee SIrea.Sude312Nmndda,VA22314.
590a Parke East BNd.
Tama, F136610
Jab a
Truss
Truss Type
pry
Ply
Walsh Residence
T18074397
J38351
ZHJ10
Diagonal Hip Girder
4
1
Job Reference (optional)
easy vast I was, IL Fleece, rL avbeic 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Sep 10 09:24:22 2019 Page 1
ID:INmuMgoEcpdh37zliasE0yjN73-hXOkvis6NwJTkN 4vEBPOBuOMNOZIUbWGc G7Yyf4Dd
-1-10-m a-1B-7 9-10-11 v10-10 1 4-10-7 an-f0 "I
ix4 II ses =5
3x3 =
Scale-1:24.9
Plate Offsets (X,Y)—
(2:D-0-14,D-1-8] (4:0-2-14 0-0-81
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(too)
fiber
Utl
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.62
Vert(LL)
0.05
6.7
>999
240
MT20
244/190
TCOL 20.0
Lumber DOL 1.25
BC 0.52
Vert(CT)
-0.07
G7
>999
180
BCLL 0.0 '
Rep Stress Inv NO
We 0.34
Horz(CT)
-0.02
4
nits
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 481la
FT es 0%
LUMBER.
BRACING -
TOP CHORD
20 SP No.2
TOP CHORD
BOTCHORD
2x4 SP No.2
WEBS
2x4 SP No.3
BOTCHORD
REACTIONS.
(lb/size) 4=210/10echanical, 2=52910-10-15, 6=363/Mechanical
Max Horz 2=167(LC 8)
Max Uplift 4=75(LC 8). 2=346(LC 8), 6=208(LC 8)
FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD
2-3=756/M48
BOTCHORD
2-7= 403/674, 6-7=-403/674
WEBS
3-6=685/418
Stnlctuml wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
Rigid ceiling directly applied or 9-0-15 cc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf; BCDL=6.Opsf, h=18ft; B=451t; L=24ft; eave=4ft; Cat.
11; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate gdp
DOL=1.60 '
2) As requested, plates have not been designed to provide for placement tolerances or tough handling and erection Conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 pat bottom chord live load nonconclument with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girders) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 1001Is uplift atjoint(s) 4 except (jl=1b)
2=346, 6=208.
8) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500m.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 45 Its down and 119 Ib up at
1-4-15, 45 Ib down and 119 lb up at 1-4-15. 93 lb down and 571b up at 4.2-15, 93 Ib down and 57 lb up at 4-2-15, and 1371Is down
and 110 lb up at 7-0-14, and 137 lb down and 110 Ib up at 7-0-14 on top chord, and 46 lb down and 53 lb up at 1-&15, 46 Ib down
and 53 lb up at 1-4-15, 541b down at 4-2-15, 54 lb down at 4-2-15. and 39 Ib down and 301b up at 7-0A4. and 39 lb down and 30
lb up at 7-0-14 on bottom chord. The design/selection of such Connection device(s) is the responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads(plf)
Vert: 14=80, 5-8=20
Themes A. Albani PE No.39380
MiTek USA, Inc. FL Cart e834
6s04 Parke East Blvd. Tampa FL 33610
Date:
September 10,2019
®WARNING-Venry design parameters add READ NOTES ON MISAND INCLUDED MITER REFERENCE PAGEMP7472 n¢ rN0]flOrS BEFORE USE.
Design rWN Or use anyweh MTek® connectors, Tals design Is based ony open parameters Minor. and Is for an Individual boating comporem am
amiss system. Defeat use. the building destgnermust vedWine oppecabigry m deep parameters and property arsamorete this design into me overall
buffiingdesign. BmdngindicffiedistaprewNW&"gafind'Mdual WsswebanNwcboNmembemmo/./WdRbnaltemporaryandpermanembracing
MiTek'
Is sliders required for stability an l to preeem collapse win passible personal injutrand property damage. For geneml guidance regarding the
fabdcedon, storage, delivery, eremion and bmCng ofbnnan, and truss systems, we ANSUTPH Duality Comde, OSaaeandaC5l aulldldg Component
690a Pads East BM.
Se/etylnformdNon avmlablehom TNee Plmelnmkme,218N.Lee M.Suxe3lZAlexandM.VA22J14.
Tampa. FL MID
Job • russ
Truss Type
Oty
Ply
Walsh Residence
T78074397
J38351 ZHJ10
Diagonal Hip Girder
q
1
Job Reference (optional)
East Coast Truss, Ft. Pierce, FL 34946
8.240 s Jul 14 2019 MTek Industries, Inc. Tue Sep 10 09:24:22 2019 Page 2
ID:INmub4goEcpdh37zljasEOyjN734iXOkviseNwJTkK 4vEBP0Bu0MNOZIUbWGc G7Yyf4Dd
+ LOAD CASE(S) Standard
Concentrated Loads (II
Vert: 11-118(F=59, 8=59) 13=-107(F=53, S=-53) 14=73(F=37, 13=37) 15=4(F=-2, B=2) 16=69(F=34, 11=34)
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M1.741`3 re¢ fON32015 BEFORE USE.
Design val4 bruse ongwdh Wows connectors. This design is based only upon parameters shown. Art is loran IMividual Wrong component not
a buss sy9en Were use, Dar Wilding deslgnermust verylhe applicablBy of design parameters and prepedybocrpogra mi. design btobe overall
7
bwldingdesign. Brssingbdicaledls to prewntbuddingofindMtlual Was web anNor NONmembeisonty. AtldrisgratemporaryeMpurnanertbraWg
MiTek'
is~required for Stability and to prawn collapse win passible personal iNmy and property damage. ForgenealguWansaregagligNe
fablkation,stoMe,deliveq.emd nandbacJngawmsm nsssygem.me ANSUTPIf Qualify Criteria, OSB49 and BCSI Building Companent
6914 Parka Ent BM.
Saretylnlormagon .gable hdn Truss Plate Inst ute. 218 N. Lee Street, Suite 312. Aleaandds, VA=14.
Tampa. FL Mi 0
Job ,
mss
Tmsa Type
Oty
Ply
Walsh Residence
T78074398
J38351
ZHJ10A
Diagonal Hip Girder
1
1
Job Reference (optional)
I ruse, m nerve, ra a,do.
3x4 =
14 2019 MiTek Industries, Inc. Tue Sep 10 09:24:23 2019
2x3 II W II 34 =6
Scele: 12-=l.
Plate Offsets (X,V)—
I5:0-3-10 Edge1 (9:0-1-12 0-2-81
LOADING (psf)
SPACING- 2-0.0
CSI.
DEFL.
in
(too)
Well
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.47
Vert(LL)
0.07
11
>999
240
MT20 2441190
TCDL 20.0
Lumber COL 1.25
BC 0.91
Vert(CT)
-0.13
11
,862
180
BCLL 0.0 '
Rep Stress Ina NO
WB 0.39
HIorz(CT)
0.09
7
me
n/a
BCDL 10.0
Code FBC2017frP12014
Matrix -MS
Weight: 56111 FT=0
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
BOT CHORD 2x4 SP No.2'Except'
3-11: 2x4 SP No.1, 4-8: 2x4 SP No.3 BOT CHORD
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 7=61/Mechanical, 2=539/0.10-15, 5=528/Mechanical
Max Harz 2=167(LC 24)
Max Uplift 2=220(LC 8), 5=165(LC 8)
Max Greg 7=96(LC 3), 2=548(LC 28), 5=528(LC 1)
FORCES. (Ib) - Max. CompJMax. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-748/154, 3d=877/209, 4-5=896/249
BOT CHORD 2-11=-208/626, 9-10=-406/1354, 4-9=348/134
WEBS 3-9=616/171, 5-9=311/1018
Structural wood sheathing directly applied or 6-0-0 oc pur ins,
except end verticals.
Rigid ceiling directly applied or 8S9 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; B=45ft; L=24ft; eave=oft; Cat.
11; Exp B; Encl., GCp1=0.18; MWFRS (directional); Cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcumenl with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss Connections.
7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 Ib uplift at joint(s) except 01--lb)
2=220, 5=165.
8) Gap between inside of lop chord bearing and first diagonal or vertical web shall not exceed 0.500m.
9) Hanger(s) or other Connection device(s) shall be provided sufficient to support Concentrated load(s) 451la down and 119 lb up at
1-4-15, 451b down and 1191b up at 1-4-15, 100 Ib down and 661b up at 4-2-15, 93111 down and 57111 up at 4-2-15, and 1501D
down and 107 lb up at 7-0-14, and 137111 down and 1101b up at 7-0-14 on top chord, and 71b down and 53 Ib up at 1-4-15, 7111
down and 53 lb up at 1-4-15, 20 lb down at 4-4-1, 161b down at 44-1. and 451b down at 7-0.14, and 391b down and 69 lb up at
7-0-14 on bottom chord. The design/selection of such Connection device(s) is the responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pIQ
Vert: 1-5=80, 11-12=20, 9-10=20, 6-8=20
Thomas, A Miami PE No.39380
MITek USA, Inc. FL Cart 0634
69M Parke East Blvd. Tampa FL 33610
Date -
September 10,2019
®WARNING - Verify design paramelers and READNOTES ON rKS AND INCLUDED MITERREFERENCE PAGE MI47473 re✓. RVOlOcISBEFORE USE.
essess
�� **e
Design veld for use antywith hiMeMconnectors. Thh design Is based onfd upon paramelers shown, and is fa an Individual auumrg exx nenl, not
obusssyslem Before use, the bdding desigrermust vedyme applimbilfty of design paamelers and proper"osiiparee Wth s design into e overan
■■���
-.YE�
�
bulliingdesgn. Bracing indicated is to prevent bucking of individual Wss web anion chord membere say. AIdbionallon faryropermaneMbraWg
Mel(
always required for steamy and to prevent canapes win possible personal injuand pmpedy damage. Furgenenlguldanceregada,une
fabrication,storage. dearerg erection and bracing of teases and truss systems. sea ANSYnot coast, Creole, DSB49 and SCSI Building Component
6904 Parke East Blvd.
SeTaybMormNoa avadable Rom Truss Rate ingRute, 218 N. Lee atmel, nude 312 A mndda, VA 22314.
Tampa, R 35610
Job y
Truss
Truss Type
pry
Ply
Walsh Residence
T18W4398
J38351
2HJ10A
Diagonal Hip Girder
1
1
n!, Reference (optional)
cam C-1 L �miw, FL S4;46 5.24U s Jul 14 ZU19 MITek Incluslnes, Inc. Tue Sep 10 09:24:23 2019 Page 2
ID:INmub4goEcpdh37zljasEOyjN73-9L672sk8ERMUZGSrez RbRmgilwBfVGjpfy(4Dc
6 LOAD CASE(S) Standard
Concentrated Loads (Ib)
Vert: 11=16(F=14, 8=2) 15=118(F=59, B=59) 16=114(F=60, B=-53) 17=73(F=37, 8=37) 18=-76(F=-42, 13=34)
®WARNING -Verify design parameters andREAD N01E5 ON THIS AND INCLUDED MITER REFERENCE PAGE MII-0 TY ns , IOX3G015 BEFORE USE.
y Design valld foruse on wtM h DeWcOarg ll This design le based any upon parameters shown, and Is for wpa an IndMduw wild, mnart, not
a buss "am. Before use. Me bulling designer must verly Ue a,danti ny of design parameters and properlNo y oryWth orde s design ago e overall
buldingdeagn. Bra gMd edislopme ntbua gof NdWualWnwebu&w Ucdmembemwy. AddWraltempomr,indpermanembracing WOW
Is always required for Mobility and to ine"M w9apwwbh pow Ne personal Irturyand pmpedy damage. Forgenew guid.n. regarding the
fabrication, storage, delivery, election and bracts oftmnes and buss systems,see AN9gfPlf Dually Contents, US889 and BOI Building Component 6906 Parke East BIA.
Safoylnformatlon avalabNh Tmsa Platelnatbue,21BN.LMMMM.Uhe312Me dda.VAn314. Tampa. FL 36610
Symbols
PLATE LOCATION AND ORIENTATION
�4 Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
(T16 r
1
For 4 x 2 orientation, locate
plates 0- y+s' from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
Plate location details available in MiTek 20/20
software or upon request.
PLATE SIZE
The first dimension is the plate
4 x 4 width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
LATERAL BRACING LOCATION
Indicated by symbol shown and/or
th
by text in the bracing section of the
output. Use T or I bracing
if indicated.
BEARING
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
Industry Standards:
ANSIlrPl1: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
Numbering System
6-48 I I dimensions shown o scale)
ixteenths
(Drawings not to scale)
1 2 3
TOP CHORDS
JOINTS ARE GENERALLY NUMBEREDILETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERSILETTERS.
PRODUCT CODE APPROVALS
ICC-ES Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber design values are in accordance with ANSUTPI 1
section 6.3 These truss designs rely on lumber values
established by others.
02012 MiTek®A t Rights Reserved
MiTek0
MiTek Engineering Reference Sheet: Mll-7473 rev. 10103/2015
® General Safety Notes
Failure to Follow Could Cause Property
Damage or Personal Injury
1. Additional stability bracing for truss system, e.g.
diagonal orX-bracing, is always required. Sea SCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, Individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of buss at each
joint and embed fully. Knots and wane atjoint
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSI?PI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
10. Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
In all respects, equal to or better than that
specified.
13. Top chords must be sheathed or purtins provided at
spacing Indicated on design.
14' Bottom chords require lateral bracing at 10 a. spacing,
or less, i1 no ceiling is Installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cot or alter buss member or plate without prior
approval of an engineer.
17. Install and load vertically unless Indicated otherwise.
18, Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
Is not sufficient.
20. Design assumes manufacture in accordance with
ANSI/TPI 1 Quality Criteria.
K.l J