Loading...
HomeMy WebLinkAboutPLANS1 III a n LING B FRAME m PLAN VIEW 2.5" BUILDING FRAMING ' RECESS 4" DOOR WIDTHI r ELEVATION VIEW BUILDING FRAMING RECESS •76"�DOOR WIDTH ROLL —UP DOOR CONCRETE SPLASH —GUARD RECESS 3'-0"-I -------------------------FRAME C OUT----------------------------------------- V�Y[rVMMrl7M i-XiEXPANSION ANCHOR WITHIN 6" OF EACH POST/TRUSS ALONG SIDES AND EVERY OTHER END —WALL POST 1.26" MIN. BASE RAIL GRADE N ZCAPACITY 2PSI 4' CONCRETE WITH W.W.F. OR FIBER MESH IMUM SOIL BEARING CONTINUOUS WITH MINIMUM 2.000 PSF (TYP.) 12. OVERLAP SPLICE CONCRETE FOUNDATION/BASE RAIL ANCHOR DETAIL \_MIN. 2,500 PSI 4" CONCRETE SLAB WITH W.W.F. (OR FIBER NOTES: MESH) AND 12"x12" REINFORCED FOOTER PERIMETER SUB -GRADE SOILS: -TO BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION R318 AND 1816 OF THE 2017 FLORIDA BUILDING CODE, 6TH EDITION CONCRETE: -MINIMUM 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS -ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE DESIGNED TO SLOPE AWAY FROM THE STRUCTURE REINFORCING STEEL (REBAR) REQUIREMENTS: -MINIMUM GRADE 40 STEEL -REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED: -THE REBAR IS BENT COLD _ -THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED 6-BAR DIAMETERS: AND -REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT IN CASES WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL CELL. THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1" HORIZONTALLY TO 6" VERTICALLY. -COVER: -2" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH SOIL OR WEATHER, AND 1j" ELSEWHERE. REBAR EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF I" FOR FINE GROUT, AND J" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL. REBAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER, AND 14" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER. GALVANIZATION: -METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY EXPOSED TO WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153, CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED. 6'-14. m WINDOW a F BY St. Lucie County woL Y UN IM M17 M FEIYm. ASDE-7-1 MANUFACTURM r__ A a*W BURRING TYPE — smucME wNSmuc1ION TYPE N-B RISK CATEcow FIRE PADTECTON NONE FIRE SUPPRESSION SYSTEM lNoIa I � 1 I I , , �/�� F • w\nV wwPANCY S1aRIDF, S-➢ BASIC WIND SFEEO Vflaempn EftPOSURE O ENCLOSURE DICIDvn INIERLUL PRESSURE wEPi1CIENT IMPORTANCE FACTOR 1.1E ROOF DF/D lDAO 10� ROOF LIVE LOAD Zppg OR 30N4 FLOOR DUD LOAD IOPs FLwR UVE LOAD WSF W RATING OF WAIS, FIDOR. ROOF WA MODULES FFR BUIDINc 11 USAGE Im HURRICANE SHELTER USAGE NO --I>-- ----�E yea sD. Fr. SWI 12"x12" REINFORCED FOOTER 3' a m- 1 6175 SouthWind Tr.. Ft. Pierce. 34951 II WERar BE WWEO. ND SHOP BE MMMUM 1/3' srEa_ NlPrvs C N W Y VA w 10/25/19 Z MattheW T. BaldWin P.E. Florida License #64608 IZ Sheet: CA-1 OF 4 12 SMNGiNG DOOR FRAME OUT WiNDDW LEFT SIDE WALL RIGHT SIDE WALL M FRAME OUR REAR SMNGING DOOR �� FO NGE V �0 00MQ o �•c'� 091 VvG` 00 lov ZCATEGORY I PROTECTION NONE FINE SUPPRESSION SYSTEM INa4E SIRII n G2 IMPORTANCE FACTOR 1.1e ROOF DEAD LOAD iWSF ROOF LINE LOAD 20PY OR 3p� NCTf IDb FLOOR DEAD LOAD 10P3 FLOOR L LOAD MSF YY RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE S11kl.TER USAGE NO S uARE FOOTAGE 17M SO. FT. 5175 SouthWind Tr., Ft. Pierce, 34951 Maa.,i. 321 X 24'W X 10'H . TIES BU 6 EXEMPT ERa_M THE RX FMMCY H /12-141' RS O 6' O.G MAIL fE WELnm. NO SHOP. BE MIMMUM 1/2' urso- NIPPLES _W (D Z_ Q Of ' 1VlV 1, L.L 0 w 10/25/19 Li Matthew T. BuldWIn P.E. Florida Ucense #64608 C) U-) Sheet: CA-2 OF 4 SWINGING DOOR FRONT END WALL FRAME OUT WINDOW LEFT SIDE WALL RIGHT SIDE WALL FRAME OUT REAR END WALL SWINGING DOOR 51 • 60 cj Q� CODE VERSION FBGGItP01a5 /NfYAm¢ M1) eN Fm , ASL4-i-f WNDFAGfURQi BUM1DING TYPE UR11Y 51eIIC11AE CONMUC11ON 1YPE 1-9 FlRE PRORCFION INWE RRE SUPPIBS9ON SYSTEM NDNE OCOUPANCY sYaRw,>: s-z Banc WIND SPEED Y 1.5 I. E% OSURE a ENCLOSURE FRar>sm INTERNAL PR URE C0099CBM +/- ws FLOOR DEAD LOAD IlmF FLOOR LIVE LOAD 60PSF W RARNG OF WA . FlDOR. ROOF N/A MODUM PER BUMNG 1 HURWCANE PROTEMON USAGE Iw HUMCANE SHELRR USAGE Iko SQUARE FOWAGE 170 5 . FT. MTB 8/4/19 AthWTnd Tr.. Ft. Pierce. 34S 32'L X 24'W X 10'H B EYEWFT MW NE 1e0 F1IERGY REOUFA/FMS ARE I ffz-14,d- R o 6' o.c. NAx IH I12-14uH' eE WnnED. No ec �iMNUN f/z' slra_ WPPUm (n W_ n n I \ w 10/25/19 LLI MattheW T. BaldWin P.E. Florida License #64608 0 v� sheet: CA-3 OF 4 MINIMUM 6' TS NIPPLE NIPPLE SECURED TO WALL POST WITH (4)/12-141j' SELF-DRIWNG SCREWS /HIPPIE AeN' FAIL F ASE POST TO BASE RAIL CONNECTION MINIMUM 6' R NIPPLE. HIPPIE SECURED TO WALL POST WITH (4)/12-14,4' SELF-DRIWNG SCREWS 2'v212' 16 CA ANGLE CUP SECURED WITH (4) 812-14,1- SELF -DRILLING END POST TO BASE RAIL CONNECTION A. ANGLE CUP SC)RE�WSX� -14 NON—STRUCTURAL HEADER OR WINDOW RAIL TO POST DETAIL INTERIOR 012-144' SELF -DRILLING SCREWS O 10' O.C. MAX. 3" MAX FROM CORNERS HORIZONTALLY/ 4- MAX FROM CORNERS VERITCAL.Y EX ERIOR DOOR FRAME TO POST CONNECTION 2X1'r2. 16 GA. ANGLE CUP SECURED WITH (4) /12-14,1' 16 GA ANGLE CUP SEW RED SELF -DRILLING SCREWS (4) 012-144' SELF-DRIWNG OR DOUBLE M HEADER INTERMEDIATE POST TO HEADER/BASE RAIL/OR HEADER CONNECTION WINDOW RAIL DETAIL DETAIL OPTION 1 2"x2"z2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14X4" SELF -DRILLING SCREWS VARIES STD. MAX. SPACIN 3" MIN. STD. MAX. SP CING 4—VARIES - SIDE WALL ROLL —UP 1 DOOR/FRAME OUT 1 HEADER DETAIL INSTALL. PER MNIUFAMRERS INSDtUCnONS SELF-DRIWNG O 6' O.C. MAX. & FROM CORNERS ROLL —UP DOOR TO POST CONNECTION DESIGN PRESSURES — 165 Mph ROOF +22.0/-48.4 WALLS +25.4/-22.8 DOORS +25.4/-22.8 WINDOWS +25.4/-22.8 1 2 3 4 5 ZONE +11.7 —25.8 +14.3 —39.1 +22.0 —48.4 +23.8 —20.1 +25.4 —22.8 26 GAUGE ROOF SHEATHING SECURED WITH (1)#12-14,1' SELF-DRIWNG SCREWS O '2-1-2-1- (6- O.C. (9- O.C. M".)) 1' 16 GAUGE FURRING CHANNEL 48" O.C. MAX. SECURED WRH (2)/12-14z1' SE1F-DRIWNG SCREWS TO EACH RAFIER. ROOF PANEL CONNECTION VERTICAL SHEATHING OPTION 16 GA U-CHANNEL BRACE. MIN. 24' UP TO T' POST. MIN. 48' OVER ]' POST. MIN. 46' TO MAX 6P FROM HORM (EXCWDE END -WALLS; MINIMUM 6" TS NIPPLE NIPPLE SECURED TO WALL POST WON (4)/12-14,1" SELF-DRIWNG SCREWS BOX EAVE RAFTER TO POST CONNECTION DETAIL MINIMUM 6' TS NIPPLE NIPPLE crn lRm TO WALL POST Wm1 44' SELF-DRIWNG SCREWS OR DOUBLE TS HEADER BUILDING TYPE HEADER CONNECTION DETAIL RISK GTECORY OPTION 2 FlRE PRO EC ON 017 BT 6 'alms A10'FNDa: W STnWNff s-2 ICUPTLNL�2J>i41I34[r-.]iaabl?uiLf�l DEAD LOAD MINIMUM 6' TS NIPPLE. NIPPLE SECURED TO WALL POST WITH RWR UVE (4)a12-14t1' SELF-DRIWNG SCREWS 'R• RA' DNC POST TO TRUSS CONNECTION 0RIll O®wG�� GG APPROVED PRODUCTS APPROVAL NO. ROOF SHEATHING Carports Anywhere FL27402.1 Hampton Rib Roof Panel WALL SHEATHING Carports Anywhere FL27403.1 Hampton Rib Wall Panel SWINGING DOOR ELIXER DOOR AND METAL COMPANY FL17996.5 407 STEEL DOOR WINDOW MI WINDOWS AND DOORS FL17499.1—R5 MODEL 185 SH tall MTB 8/4/19 Dthwind Tr., Ft. Pierce, 34951 321 X 24'W X 10'H IS Bull" Mom THE m ENERGY WOE PER SECTION CIOIAZ DIG SHALL BE N KSI SIEELL AND GALVANGATDN PER ASR1 A1o03/At W3N-16. :IRICh. INGMS/EGRESS. PROPERLY O/OR OMER LOCAL CODE MURDNEMS ME RED OF NE OWNEIL SHEATIONG MUM WRH /12-14.1' NONMflONNSS 5 SECURED WHIM iY12�-n1�� /4' uIIG CONNECrNINS APE M BE WDDED. NO NL WDOARG WNE IN SHOP. � N TM9a � BE NNMUN 1/2• 'All IS 2b5¢.6' TUBE SIFFL NIPPLES VA 10/25/19 Matthew T. Baldwin P.E. Florida License 064608 Sheet: CA-4 OF 4