Loading...
HomeMy WebLinkAboutMANUALS0 ou a0 F- wW Z C7 m N E w w � N Q � 0 3 U 0 E 9 1 8 1 7 RESIDENTIAL GENERIC STRUCTURAL PLAN. 1GERnFriHATTH SHEETINGs1 COMMON SOLAR COMPONENT EXAMPLES SHOWN- Acc arATEuucuuTED' APPEARANCE MAY VARY. EOUIPMOn DTADLOAD&THISIS CNmISDRAW IRONRIDGE PV RAIL GENERIC INSTALLATION PLAN 1. THIS IS A SINGLE SHEET GENERIC STRUCTURAL PLAN. ELECTRICAL PLAN IS SEPARATELY SEALED DOCUMENT. 2. THIS PLAN OFFERS THREE INSTALLATION METHODS. a. FRAMING METHOD. SEE DRAWINGS. b. SHEETING METHOD. SEE DRAWINGS. C. STANDING SEAM/PBR (PURUN-BEARING) METAL ROOF. USE CLAMP/BRACKET OF CHOICE; ACE. http://www.pmcind.com/aceclamp/ S-5. https://www.s-5.com/products/clamps-brackets/s-5-u-clamps/ https://www.s-5.com/products/ciamps-brackets/proteabracket/ 3. CONTRACTOR SHALL MAKE CLEAR TO AHI WHICH INSTALLATION DETAILS WILL BE USED. 4. SOLAR EQUIPMENT ADDS LESS THAN 4-PSF GRAVITY LOAD TO STRUCTURE. S. THERE SHALL BE A PV MODULE TO RAIL MOUNTING CLAMP AT EVERY MODULE/RAIL CROSSING POINT WITH MINIMUM 4 CLAMPS PER MODULE. ADJOINING MODULES SHALL SHARE MID CLAMPS. MODULES MAY BE LANDSCAPE OR PORTRAIT AT CONTRACTOR OPTION. 6. PV MOUNTING RAILS SHALL BE INSTALLED PERPENDICULAR TO ROOF FRAMING. SEE ROOF ATTACHMENT SPAN TABLE @ LOWER RIGHT 7. THERE SHALL BE A MINIMUM OF TWO RAILS UNDER EACH PV MODULE. 8. RAILS SHALL NOT CANTILEVER BEYOND OUTSIDE OF END ROOF ATTACHMENT BY MORE THAN V 9. RAILS SHALL ATTACH TO ROOF THRU L-FEET AS SHOWN HEREON. L-FEET REQUIRE FLASHINGS WHICH CAN BE SF -SO (SELF -FLASHING, SHEETING ONLY) SHOWN HEREON OR MIN 4" x 8" x 26 GA. GALV , 0.032 ALUM, OR INDUSTRY STANDARD OEM FLASHINGS OVER ATTACHMENTS LAGGED INTO ROOF FRAMING, E.G. SOLAR MOUNT, IRONRIDGE FLASHFOOTIor2, OTHER ACCEPTABLE TO AHI. 10. SF -SO ROOF ATTACHMENTS ARE INTENDED TO BE INSTALLED INTO SHEETING ALONE, HAVE BEEN SO TESTED AND ARE RATED AT 900-POUNDS ALLOWABLE PER ROOF ATTACHMENT. 11. ALL FLASH INGS SHALL BE INSTALLED IN A GENEROUS BED OF FLORIDA PRODUCT CONTROL APPROVED(PCA) POLYURETHANE ROOF SEALANT. 12. LONG L-FEET &/OR STANDOFFS ARE PERMITTED AS NEEDED FOR ROOF CLEARANCE. 13. ENGINEER OF RECORD (EOR) PREFERS EMAIL COMMUNICATION: etC-( r � IRONRIDGE RAIL, rr-q-`y- i I APP�RANCE MAY VARY I / 3/8-16x3/4J HEX HEAD BOLT I �IRONRIDGE 318-16 I STANDARD �•.if FLANGE BOLT W OREOR7-IN L-FOOT. FOR _ GALVANIZED `MIN. 4#14XZ' ERAT P PLATE PER ATTACHMENT � ++ 4 •A ^° EPDM GASKET I EMS _SS 1�3/8'SS BOLT ' ^. `SHEErINGONLY. SELF.FLASHINGROOFATTAGHMEM MID CLAMP PV RAIL I 6 5 //// 4 1 3 2 �0 FBC 2017 (6'H EDITION) FLORIDA BUILDING CODE �Z DESIGNED FOR VDLT=200 MPH., NO PLANS ON FILE - EACH PERMIT REQUIRES SIGNED & 3� RISK II, EXPOSURE D. RAISED SEAL PLAN FROM FOR -,,� PVMODULEGROUNDING MID-CLGROUN IN MP EXISTING ASPHALTO \ SHINGLE ROOF 4- MINIMUM #12 X 2-INCH, SS, SMS 03 SHINGI rLE,SINGIEPLY ¢wcxrs IRONRIDGE FIASHFOOT 2 SEE. FIGURE 11 EXISTING ASPHALT / SHINGLE ROOF 318-I6x3/4 HEX HEAD BOLT 3/8 - 16 FLANGE NUr SS METAL PLATE, SQUARE OR ROUND ROOF SHEATHING EXISTING FLORIDA PRODUCT FOAMJ f �—�T ADHESIVE \tll FRAMING APPROVED SEALANT J EXISTING FOUR # 14 QLS UNDERLAYMENr SCREWS I"BEYOND BOTTOM OF DECK FLATTL£ ROOFATTACHMENT 04 3/8 -16 x 314 PV RAIL HEX HEAD BOLT, 3/8 - I6 F ANHE NUT PV MODULE S S SS PRO .- CKEr ROOF EXISTING CM' >PBR, SHEATHING FRAMING A CN 5/16" S. LAG W/ 3" 6MM X 25 MM BI- PROFILE THREAD EMBEDMENT IN METALSHEETSCREbV BLOOONG, 301ST, OR TRUSS OS `M'SHFOOT2 SHINGLE ROOF ATTACHMENT DB B57ROTEI BMCHEr METAL R00F ArTACHMEM MID-0AF1P PV RAIL EXIST.-16 Dnnc rest '3/8 318 -16 x 314 HEX: HEAD BOLT FLANGE NUT PV RAIL SERRATED L ROOF MOUNT OPTIONAL FILL CAVDY WITH TILE ROOF TILE ROOF DOW FOAM I WATER PROOFING OR LONG WITH SONOVSTIC -L-FOOT MIN.4 #14 X Z° SMS -SS NP-1 OR EQUAL 1" BEYOND BOTTOM OF DECK POLYURETHANE CAULK PZI: ROOFINTERIOR PZ2: ROOF PERIMETER (MIN. T & LEAST OF 40% EAVE HEIGHT OR 10%BUILDING WY. PZ3:OUTSIDECORNERS L & W = PZ2, a= PZ2 WIDTH., h = EAVE HEIGHT. DECKING ON ROOF SHEATHING WATER PROOFING 6" CRS. LAG W/ 3" THREAD EMBEDMENT BLOCKING, 30IST, OR TRUSS 9 1 8 1 7 1 6 1 5 1 4 w Proper Flashing Placement MAY VAST-0IMISpgRWD/ETC. rH � COMPIEIFD LOSLOPEATTACHMEM waPnoNALREouNBAHrwPrARGEr LD SE FASHINGATTACHMENTPHOT05 1 Suv: xrs v o ® � m m 23/16 SS PROTFA BMCNET 1518 Huts 35/i6 a � �1 5/16 MINIMUM gCEauaP THREAD EMBEDMENT 55L CLAMP ',. `IRONRIWERPSHFOOT2 y., `APPROVED METALROOFCLAMP3 A BMCK7 /lr IRONRIDGE Roof Mount System XRIS Rid! 101,110011911 XR1DWW Handed SP00" AbwyreNemsenllnsrel The N-ma+a reeldsnuGl AheavywalghlmcartWs AFnns Deslnlemalapkes far restarts wlM him ums Wlar MOLM&V W1 reO M amwnerelei projects lar seamless ownectlons. ' wepenrlMrapalm • B'spwmlogeaPabUy . 12spannWrepabsrtY • BdidNOrpawwa • Madmele load wpaN91y • Heavy load rapabisly • Marina load eapabloy • Va0v rarebne for rate • Clawandblack Wah • Cher and Nark P&A • Clow snadbed fntsh • Fomu-ease tenaing UFDs Stopper Sleeves thounis Luse MlosbnerlM101a L 11—L FleshFoort Slslbrtl L-Fast Bonding Hanware Fbuh SlnWeOe MWM Vt� 1L 4 ) W DGE R W FMOUM SYSTEM CAMPONETIIS xuD x/A 13 IRON 3 2 FLORIDA ROOF ATTACHMENT SPACING (FEET): ROOF HEIGHT <30-FT 8 ROOF SLOPE <30° WIND (MPH) PZ1 PZ2 PZ3 IRONRIDGE RAIL 110 8 6 4 XRdO 120 8 6 2 XR-10 130 fi 4 2 XR-100 140 6 4 2 XR-100 150 fi 4 2 XR-100 160 fi 4 2 XR-1000 no 4 4 xR-mdD teD 1 ENGINEER ALLEN GEZELMAN lssoz HANNA RD. LUTZ, FLORIDA 33549 PH.813 9091956 Allen(]GezelmanPE.csm www.GezelmanPE.mm PE 59180 asA[AR 12 .flD W l mnu� wooW ,.i DRAFTSMAN: ALPER ICELI alpeacaliQmaii.usl.etlu APPROPRIATE LICENSE OR OWNER/BUILDER A C 0 E AI -I R-7 08.AUG.18 F 1 MONO 72M HELIENE HEL'IENE,INC. IS A PREMIER SOLAR MODULE MANUFACTURER, SERVICING THE GROWING SOLAR ENERGY MARKETS OF•NORTH AMERICA. COMBINING PROVEN'EUROPEAN TECHNOLOGY WITH NORTH AMERICAN INGENUITY ALLOWS HELIENE TO MAKE A REAL COMMITMENT IN PROVIDING SMARTER ENERGY'CHOICES,FOR THE FUTURE. HELIENE www.heliene.com H rl GUARANTEED POSITIVE POWER SORTING: [-0 : +4.99 WPI AVAILABLE IN 1000V OR 1500V SYSTEM VOLTAGE RATING MANUFACTURED ACCORDING TO INTERNATIONAL QUALITY SYSTEM STANDARDS: IS09001 ® H-BLACK INTEGRATION AVAILABLE (ALL -BLACK MODULE) `I LINEAR PERFORMANCE GUARANTEE .m,. .umu.W mnuua immz s Macz gDUfDVALUEF@0 @$ 90.00x MUE4fNfSLINFgD W4RUq g 85.00% E , eaoox Tsacx zaoaz You 720 � 99a mm, iIemm yx mm ��r • IL 1 i� Iroemm 1 I' i mi�na.4[ e et q ) •le Smm I ex. emm r, I � hemp .M rCEs�-i®n, LJ SCANNED BY St. Lucie County ELECTRICAL DATA (STC) _ _ ■ Peak Rated P'ower�,LPzw(W)_�37036 �[. .3-0O� r'335� _,. .,r_350 Maximum Power Voltage V M 40153 39713 39.133 38503 38213 ' hlaxlmum PewerCurrent— I fA) 9'28 913 I'�9:01 889 889 Open Circuit Voltage V.(V) 48.81 4819 47.57 46.95 46.64 shWEIrcmt Current �''.Isc'.IA) 097_�r 9g1��Tfi5J1r� 9.49 �._9.41_� Module Efficiency* Elf(%) , 19.3 188 18.3 17.8 17.5 Pow!ef Output ioleraace �J�_.__ �_ _ _T 0 +4.991 Wp STC - Standard Test Conditions: Irradiation 1000 W/m2 - Air mass AM 1.5 - Cell temperature 25 °C • Calculated using maximum power based an full positive output tolerance [-0 ,+4.99] Win MECHANICAL DATA rl0!mensiuns(LxWx`G) _ 11956x992x'40mm(77x 39 Weight ^ 236 kg(524Its) :Output Cables �6 � 1 1 m143 3 inch) symmeUiczl cables wdh MC9 rypeconnecters � �- H h f lunation Boa �~ IP 67 rated with 3 bypass diodes i frome 6ouble webhed 15 micron anodized aluminum alloy Front Glass Low -Iran content, Nigh -transmission PV solar glass ar Cells µ rr�72 MOnacrystalline cells(156 x 156 mm) CERTIFICATIONS I ULOsted I ULClORO-G17034,0L1703; ULi 703 Fire Classification Type l' { IEC fisted IEC 61215, IEC 61730 ! _ All I eliene modules are certified under the California Energy Commislon (CEC) Usting Report TEMPERATURE RATINGS PACKAGING CONFIGURATION (Nominal Operating Cell r p 1Modules per box:i-_'Iu Y6 pieces-T� 9 +45°CYt2°C) I1 Temperalure (NGGp t i--�------_-_..-- 0- Modules per 53'trailec IAOpieces Temperature Coefficient of Pm-0.39%1°C - - -- —� -- --� -- - j Temperature reCoeffcient of V°� 0.31%7°C J Temperature Coefficient of 1. _ 0.045%PC J MAXIMUM RATINGS Opeiatlono Temperature ; Max System Voltage INov /1500V OIL/IEC) Max Series Fuse Rating { 15 A I WARRANTY i _ Manufacture's Workmanship Vlarranty� IlOYeer 125 Year Linear Power Guarantee (Refer to product warranty page for details) ® CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. 141 ® 0 © 2017 Heliene Inc. All rights reserved. Specifications included in this datasheet are subject to HELIENE 1B change without notice. Data Sheet Enphase Networking Enphase IQ Combiner 3 (X-IQ-AM1-240-3) LISTED To learn more about Enphase offerings, visit enphase.com The Enphase IQ Combiner V with Enphase IQ Envoy'" consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart • Includes IQ Envoy for communication and control • Flexible networking supports Wi-Fi, Ethernet, or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and optional consumption monitoring Simple • Reduced size from previous combiner • Centered mounting brackets support single stud mounting • Supports back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV or storage branch circuits Durable NRTL-certifted NEMA type 3R enclosure Five-year warranty UL listed n ENPHASE. Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 X-IQ-AM1-2403 IQ Combiner with Enphase IQ Envoy' printed circuit board for Integrated revenue grade PV production metering (ANSI C12.20+/-0.5%) and optional* consumption monitoring (+/-2.5%). ACCESSORIES and REPLACEMENT PARTS (not included, order separately) Enphase Mobile Connect' CELLMODEM-03 (4G / 12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01 3G/5-year data plan) microinvetters.(Available In the US, Canada. Mexico, Puerto Rico, and the US Virgin Islands, CELLMODEM-MI(4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) Consumption Mcnitoring-CT CT-200-SPLIT Split core current transformers enable whole home consumption metering (+/- 2.5%). Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. BRK-10A-2-240 Circuit breaker, 2 pole, 10A, Eaton BR210 BRK-15A-2-240 Circuit breaker, 2 pole, 15A, Eaton BR215 BRK-20A-2P-240 Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01 Power line carrier (communication bridge pair), quantity 2 XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS Rating System voltage Eaton BR series busbar rating Max, continuous current rating (output to grid) Max. fuse/circuit rating (output) Branch circuits (solar and/or storage) Max. continuous current rating (input from PV) Max, total branch circuit breaker rating (input) Continuous duty 120/24D VAC, 60 Hz 125 A 65A 90 A Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) 64 A 80A of distributed generation / 90A with IQ Envoy breaker included Production Metering CT 200 A solid core pre -installed and wired to 10Envoy MECHANICALDATA Dimensions (WxHxD) 49.5 x 37.5 k 16.8 cm (19.5' x 14.75' x 6.63'). Height is 21.06" (53.5 cm with mounting brackets). Weight 7.5 kg (16.51bs) Ambient temperature range-40- Cie +46-C(-40°to 115-F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes 2C A to 5O A breaker inputs: 1410 4 AWG copper conductors • 60 A breaker branch input: 4to 1/0 AWG copper conductors • Main lug combined output: 10to2/OAWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.111b/g/n Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) Cellular Optional, CELLMODEM-01 (3G) or CELLMODEM-03 (413) or CELLMODEM-Ml (4G based LTE-M) (not included) COMPLIANCE Compliance, Combiner UL 1741 CAN/CSA C22.2 No. 107.1 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Compliance, IQ Envoy UL 60601-1/CANCSA 22.2 No. 61010-1 ' Consumption monitoring is required for Enphase Storage Systems. To learn more about Enphase offerings, visit enphase.com 02018 Enphase Energy. All rights reserved. All trademarks or brands In this document are registered by their respective owner. ENPHASE. RSTC Enterprises, Inc. 2214 Heimstead Road Eau Claire, WI 54703 715-830-9997 SOLADECK FLASHED PV ROOF -MOUNT COMBINER/ENCLOSURES Outdoor Photovoltaic Enclosures Composition/Cedar Roof System ETL listed and labeled Report # 3171411 PRT-002 Revised May, 2018 • UL50 Type 3R, 11 Edition Electrical equipment enclosures • CSA C22.2 No. 290 Nema Type 3R • Conforms to UL 1741 Standard 0799 Series Includes: 0799-2 Wire size 2/0-14 0799-5 Wire size 14-6 0799-0 Wire size 14-8 Models available in Grey, Black or Stainless Steel Basic Specifications Material options: • Powder coated, 18 gauge galvanized 90 steel (1,100 hours salt spray) • Stainless steel Process - Seamless draw (stamped) Flashing - 15.25" x 17.25" Height - 3" Cavity - 255 Cubic inches Base Plate: • Fastened to base using toggle fastening system 5 roof deck knockouts Knockout sizes: (3) .5", (1) .75" and (1) 1" 8", 35mm slotted din rail Ground Block Passthrough and combiner kits are available for either AC or DC applications. 0799 Series SdaNck MmG SdaOed�G)99-0G Data Sheet Enphase Microinverters Region: AMERICAS Enphase IQ 7 and IQ 7+ Microinverters 9 To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7 Micro' and Enphase IQ 7+ Micro" dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envor, Enphase IQ Battery'", and the Enphase Enlighten'" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60-cell and 72-cell* modules More than a million hours of testing Class II double -insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) 'The 10 7+Micro is required to support 72-cell modules. v ENPHASE. Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA (DC) IQ7-60.2-US/IQ7-60-B-US IQ7PLUS-72-2-US / IQ7PLUS-72-B-US Commonlyused module pairings' 235 W-350 W+ 235W-440W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27V-37V 27V-45V Operating range 16V-48V 16V-60V Min/Max start voltage 22V/48V 22V/60V Max Do short circuit current (module Ise) 15 A 15A Overvoltage class DC port II It DC port backfeed current 0A 0A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L-L) vohage/range' 240V/ 208V/ 240V/ 208V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit' 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current OA 0A Power factor setting 1.0 1.0 Power factor (adjustable) 0.85 leading... 0.85 lagging 0.85 leading... 0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V CEC weighted efficiency 97.0 % 97.0 % 97.0 % 97.0 % MECHANICALDATA Ambient temperature range -40-Cto+65°C Relative humidity range 4%to 100%(condensing) Connectortype(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4 (or Amphenol H4 UTX with additional Q-DCC-S adapter). Connector type (IQ7.60-B-US & IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: - PV2 to MC4: order ECA-S20-S22 -PV2 to UTX: order ECA-S20-S25 Dimensions (WxHxD) 212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double -insulated, corrosion resistant polymeric enclosure Environmental category UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnIighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use asthe load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1. UL1741/IEEE1547, FCC Part lS Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors,when Installed according manufacturer's instructions. 1. No enforced DC/AC ratio. Seethe compatibility calculator at 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverlers per branch In your area. To learn more about Enphase offerings, visit enphase.com v E N P HAS E. C 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-11-19 ZA& IRONRIDGE Built for solar's toughest roofs. Datasheet Flush Mount System IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 25-year warranty. Strength Tested All components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. UL 2703 Listed System Entire system and components meet newest effective UL 2703 standard. PE Certified Pre -stamped engineering letters available in most states. Design Assistant Online software makes it simple to create, share, and price projects. 25-Year Warranty Products guaranteed to be free of impairing defects. Datesheet — XR Rails O XR10 Rail XR100 Rail XR1000 Rail Bonded Splices ----•g . . ---- A low -profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability • 6'spanning capability • 12'spanning capability • Self -drilling screws • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails • Clear and black finish • Clear and black finish • Clear anodized finish • Forms secure bonding Clamps & Grounding O UFOs Universal Fastening Objects bond modules to rails. • Fully assembled & tubed • Single, universal size • Clear and black finish — Attachments O FlashFoct2 Stopper Sleeves CAMO Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • Sized to match modules • Clear and black finish Conduit Mount Bond modules to rails while staying completely hidden. • Universal end -cam clamp • Tool -less installation • Fully assembled Slotted L-Feet Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction Bonding Hardware IAW i j L4 �. l •� Flash and mount XR Rails Flash and mount conduit, with superior waterproofing. strut, or junction boxes. • Twist -on Cap eases install • Twist -on Cap eases install • Wind -driven rain tested • Wind -driven rain tested • Mill and black finish • Secures 3/4" or 1" conduit — Resources Design Assistant — Go from rough layout to fully engineered system. For free. Go to IronRidge.com/design ELi.- � Drop -in design for rapid rail Bond and attach XR Rails attachment. to roof attachments. Secure rail connections • T & Square Bolt options Slot for vertical adjusting • Nut uses 7/16" socket Clear and black finish • Assembled and lubricated NABCEP Certified Training NABCEP Earn free continuing education credits, while learning more about our systems. %0 Go to IronRfdge.com/training 02619bonRidgoInc. All rights reserved US. Patents:. 118,695,8901 19,819,303;49,865,938; Others Pending. Version 1.76 1495 Zephyr Avenue 1495 Zephyr Avenue /%lam IRONRIDGE Hayward, CA 94544 /�� IRONRIDGE I Hayward, CA 94544 1-800-227-9523 1-800-227-9523 IronRidge.com IronRldge.com Attn: Corey Geiger, COO, IronRidge Inc. Date: September 7s', 2018 Re: Structural Certification and Span Tables for IronRidge Flush Mount System This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System. The Flush Mount System is a proprietary rooftop mounting system used to support photovoltaic (PV) modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails and secured to the rails with IronRidge mounting clamps. The XR Rails are side mounted to a selected roof attachment with 3/8" stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core components are shown in Exhibit EX-0015. The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards listed below, for the load conditions and configurations tabulated in the attached span tables. . ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures (ASCE 7-10) . 2015 International Building Code (IBC-2015) . Florida Building Code 6N Edition (2017) Building . 2015 Aluminum Design Manual (ADM-2015) The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B, C, & D, roof zones 1, 2 & 3, and roof slopes from 00 to 450. The span tables are applicable provided that the following conditions are met: 1. Span is the distance between two adjacent roof attachment points (measured at the center of the attachment fastener) 2. The underlying roof pitch, measured between roof surface and horizontal plane, is 45e or less. 3. The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from grade, does not exceed 30 feet 4. Module length shall not exceed the listed maximum dimension provided for the respective span table and module width shall not exceed 48". 5. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Mount installation manual and other applicable standards for general roof construction practice. 02018 InmRidge, (no. FL Flush Mount System Certification Leger-1 The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules, or the underlying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components In regards to the applied or resultant loads of any chosen array configuration. Sincerely, Gang Xuan, PE, LEED AP Senior Structural Engineer 020181ronRidge, Ina FL Flush Mount System Certification Letter-4 Insert Frameless Kit T-bolt in top rail slot. Place star washer over T-bolt, allowing it to rest on top of rail. Secure module clamps with a hex nut and torque to 80 in-lbs. 9 Tested or evaluated module clamps: • Sunforson silver or black SFS-UTMC-200(B)mid and SFS- UTEC-200(B) and clamps. • Sunpreme silver or black mid and end clamps with part numbers 7500105X where "X" Is 1, 5, 6 or 7. • IronBidge sliver or black mid and end clamps with part numbers FMLS-XC-001-Y where"X" is E or M and "Y• Is B or blank. 9 Follow module manufacturer's Installation Instructions to Install the module clamps. 9 Frameless modules require using a Grounding Lug on every rail. 9 For Sunpreme Modules Only: If required to use slide prevention hardware, see Module Slide Prevention Addendum (Version 1.10). Star wa4rer� \ (BOInAeI \ Req.Z' -nhE on E., Hall MODULE! e The Flush Mount System may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, "me refers to the module power rating and bath black and silver frames are included in the certification. ee Amedsolar Modules with 35, 40 and 50mm frames and model identifier ASbYxxxZ; where "b" can be 5 or 6; "Y" can be M, P, M27, P27, M30, or P30; and "Z" can be blank, W or WB. Modules with 35, 40, and 45mm frames and model identifier aaSM66yyPzz-xxx; where "aa" can be CH Astronergy Solar or A; "W can be either 10 or 12; and "zz" can be blank, HV, (BF) or (BL). Frameless modules with model identifier CHSM661 OP(DG)-xxx. Auxin Modules with 40mm frames and model Identifier AXN6y6zAxxx; where "y" can be M or P; "z" can be 08, 09, 10, 11, or 12; and "A" can be F or T. Axltec Modules with 35 and 40mm frames and model identifier AC-xxxY/aa-ZZ; where "Y" can be M or P; "aa" can be 125 or 156; and "ZZ" can be 54S, 60S or 72S. Boviet Modules with 40mm frames and model Identifier BVM66aaYY-xxx; where "aa" can be 9, 10 or 12; and "YY" is M or P. BYD Modules with 35mm frames and model Identifier BYDxxxAY--ZZ; where "A" can be M6, P6, or PH; "Y' can be C or K; and "ZZ" can be 30 or 36. Modules with 30, 35 and 40mm frames and model identifier CSbY-XXXZ; where'b" can be 1, 3 or 6; "Y" Canadian Solar can be H, K, P, U, V, or X; and "Z" can be M, P, MS, PX, M-SD, P-AG, P-SD, MB-AG, PB-AG, MS -AG, or MS -SD. Frameless modules with model identifier CSbY-xxx-Z; where "b" can be 3 or 6; "Y" is K. P, U, or X; and "Z" can be M-FG, MS-FG, P-FG, MB-FG, or PB-FG. CertainTeed Modules with 35 and 40mm frames and model identifier CTxxxYZZ-AA; where "Y" can be M or P; "ZZ' can be 00,01, 10, or 11; and "AA" can be 01, 02 or 03. CSUN Modules with 35 and 40mm frames and model identifier YYxXX-zzAbb; where "YY' is CSUN or SST; "zz" is blank, 60, or 72; "A" is blank, P or M; and "bb" is blank, BB, SW, or ROOF. Ecosolargy Modules with 35, 40, and 50mm frames and model identifier ECOxxxYzzA-bbD; where "Y' can be A, H, S, or T; "zz" can be 125 or 156; "A" can be M or P; "bb" can be 60 or 72; and "D• can be blank or B. ET Solar Modules with 35, 40, or 50mm frames and model Identifier ET-Y6zZxxxAA; where "Y" is P, L, or M; "zz" is 60 or 72; and "AA" Is WB, WW, BB, WBG, WWG, WRAC, WBCO, WWCO, WWBCO or BBAC. ® 2b191RONRIDGE, INC. VERSION. 2.0 FLUSH MOUNT INSTALLATION MANUAL- 11 MODULE COMPATIBILITY Modules with 35, 40, or 50mm frames and model Identifier FXS-xxxYY-ZZ; where ")c&' is the module Flex power rating; "YY" is BB or BC; and "ZZ" is MAA1 B, MAA1 W, MAB1 W, SAA1 B, SAAI W, SAC1 B, SACIW,SADIW,SBAI6,SBA1W, SBC1B,or SBC1W. GCL Modules with 35 and 40mm frames and and model identifier GCL-a6/YY xxx; where 'W can be M or P; and "YY" can be 60, 72, or 72H. GlgaWatt Solar Modules with 40mm frames and model Identifier GWxxxYY; where "YY" is either PB or MB. Hansel Modules with 35 and 40mm frames and model identifier HS)=YY-zz; where "YY" can be TB, TD, US or UD; and "zz" can be ANt, AN3, AN4. Hanwha Solar Modules with 40, 45, or 50mm frames and model identifier HSLaaP6-YY-1-xxxZ; where "aa" Is either 60 or 72; "YY" is PA or PB; and "Z" is blank or B. Modules with 32, 35, 40, and 42mm frames and model Identifier aaYY-ZZ-xxx; where "am" can be Q. or B.; "YY" can be PLUS, PRO, PEAK, LINE PRO, LINE PLUS, or PEAK DUO; and "ZZ" can be G3, G3.1, Hanwha Q CELLS G4 G4.1, L-G2, L-G2.3, L-G3, L-G3.1, L-G3y, L-G4, L-G4.2, L-G4y, LG4.2tTAA, BFR-G3, BLK-G3, BFR-G3.1, BLK-G3.1, BFR-G4, BFR-G4.1, BFR G4.3, BLK-G4.1, G4/SC, G4.1/SC, G4.1/rAA, G4.1/ MAX, BFR G4.1TFAA, BFR G4.1/MAX, BLK G4.1/rAA, BLK G4.1/SC, EC-G4.4, G5, BLK-G5, L-135, L-G5.1, L-G5.2, L-1215.2/1-1, L-G5.3, G6, BLK-G6, L-G6, LG6.1, LG6.2, or LG6.3. Helene Modules with 40mm frames and model identifier YYZZxxx; where "YY" is 36, 60, 72, or 96; and "ZZ" is M, P, or MBLK. Hyundai Modules with 35, 40 and 50mm frames and model identifier HIS-YxxxzZ; where "Y' can be M or S; and "ZZ" can be KI, MI, MF, MG, SG, RI, RG(BF), RG(SK), TI, or TG. Itek Modules with 40 or 50mm frames and model identifier IT-Xxx-YY; where "YY" is blank, HE, or SE, or SE72. Modules with 35,40 and 45mm frames and model identifier JAyyzz-bb-xxx/aa; where W can be M, P. JA Solar M6 or P6; "zz" can be blank, (K), (L), (R), (V), (BK), (FA), (TG), (FA)(R), (L)(BK), (L)(TG), (R)(BK), (R) (TG), (V)(BK), (BK)(TG), or (L)(BK)(TG); "bb" can be 48, 60, 72, 60S01, 60SO2, 60S03, 72501, 72S02. 72S03; and "aa" can be MP, Sl, SC, PR, PR/150OV, 3BB, 48B, 4BB/RE, 4BB/150oV, 5BB. Modules with 35 and 40mm frames and model identifier JKMYxxxZZ-aa; where "Y" can either be blank Jinko or S; "ZZ" can be P, PP, M; and "aa" can be blank, 60, 60B, 50H, 60L, 60BL, 60HL, 60HBL, 60-J4, 609- J4, 60B-EP, 60(Plus), 60-V, 60-MX, 72, 72-V, 72H-V, 72L-V, 72HL-V or 72-MX. Frameless modules with model Identifier JKMxxxPP-DV. Modules with 46mm frames and model Identifier KYxxxZZ-AA; where "Y" is D or U; "ZZ" is blank, GX, or Kyocera SX; and "AA" is LPU, LFU, UPU, LPS, UPS, LFB, LFBS, LF82, LPB2, 3AC, 3BC, 3FC, 4AC, 480, 4FC, 41,10, 5AC, 5BC, 5FC, 5UC, 6BC, 6FC, 8BC, 6MCA, or 6MPA. LG Modules with 35, 40, and 46mm frames LGxxxYaZ-bb; where "Y" can be A, E, N, 0, S; "a" can be 1 or 2; "Z" can be C, K, T, or W; and "bb" can be A3, A5, B3, G3, G4, K4, or V5. Longi Modules with 40 and 45mm frames and model identifier LR6-YYZZ-=M; where "YY" can be 60 or 72; and "ZZ" can be BK, BP, HV, PB, PE, or PH. Mission Solar Modules with 40mm frames and model identifier MSExxxZZaa; where =can be MM, SE, SO or SO; and "as" can be 1J, 4J, 4S, 5K, 5T, 6J, 6S, 6W, 8K, 8T, or 9S. Mitsubishi Modules with 46mm frames and model identifier PV-MYYxxxZZ; where "YY" is LE or JE; and "ZZ" is either HD, HD2, or FB. Motech IM and XS series modules with 40, 45, or 50mm frames. Nee Solar Power Modules with 35mm frames and model identifier D6YxzxZZaa; where "Y" can be M or P; "ZZ" can be 63A, 64A, E3A, E4A, 1-13A, H4A; and "aa" can be blank, (TF), ME or ME (TF). Modules with 35 and 40mm frames and model identifier VBHNxxxYYzzA; where "YY" can be either SA Panasonic or KA;'Yz" can be either 01, 02, 03, 04, 06, 06B, 11, 11 B, 15, 15B, 16, 16B, 17, or 18; and "A" can be blank, E or G. Palmer Modules with 40mm frames and model identifier SGxxxYzz; where "Y' can be M or P; and "zz" can be blank, (BF), or (FB). Phone Solar Modules with 35, 40, or 45mm frames and model identifier PSxxxY-ZZA; where "Y" Is M or P; "ZZ" is 20 or 24; and "A" is F, T or U. ® 2019 IRONRIDGE, INC.. VERSION 2.0 _, FLUSH MOUNTINSTALLATION MANUAL- 12. Prism Solar Frameless modules with model Identifier BiYY-xxxBSTC; where "YY" can be 48. 60, 608, 72 or 72S. REC Solar Modules with 30, 38 and 45mm frames and model Identifier REC)=YYZZ; where "YY" can be M, NP, PE, TP, TP2, TP2M, TP28M, or TP2S; and "ZZ" can be blank, Black, BILK, BLK2, SLV, or 72. Renesola Modues with 35, 40 or 50mm frames and model identifier JCtoorY--ZZ; where "Y" is F, M or S; and "ZZ" is Ab, Ab-b, Abh, Abh-b, Abv, Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, or Db-b. Renogy Modules with 40 or 50mm frames and model identifier RNG-xxxY; where "Y" is D or P. S-Energy Modules with 40mm frames and model identifier SNxxxY-ZZ; where "Y" is M or P; and "ZZ" is 10, or is. Seraphim Energy Group Modules with 40mm frames and model identifier SEG-6YY-xxxZZ; where "YY" can be MA, MB, PA, PB; and "ZZ" can be BB, WB, or W W. Seraphim USA Modules with 40 and 50mm frames and model identifier SRP-xxx-6YY; where "YY" can be MA, MB, PA, PB, OA-XX-XX, and OB-XX-XX. Sharp Modules with 35 or 40mm frames and model identifier NUYYxxx; where "YY" is SAor SC. Silfab Modules with 38mm frames and model identifier SYY-Z-xxx; where "YY" is SA or LA; SG or LG; and "Z"is M, P, or X. Solaria Modules with 40mm frames and model identifier PowerXT xxxY-ZZ; where "Y" can be R or C; and "a" can be AC, BD, BX, BY, PD, PX, PZ, WX or WZ. SolarTech Modules with 42mm frames and model identifier STU-x YY; where "YY" can be PERC or HJT. SolarWorld AG / SolarWodd Sunmodule Plus, Protect, Bisun, XL, Bisun XL, may be followed by mono, poly, duo, Industries GmbH black, bk, or clear; modules with 31, 33 or 46mm frames and model identifier SW-)=. SDIarWorld Americas Inc. SolarWodd Sunmodule Plus, Protect, Bisun, XL, Bisun XL, may be followed by mono, poly, duo, black, bk, or clear; modules with 33mm frames and model identifier SWA-xxx. Stion Thin film modules with 35mm frames and model identifier STO-xxx or STO-xxxA. Thin film frameless modules with model identifier STL-xxx or STL-xxxA. Modules with 35, 40, or 50mm frames and model identifier SE-YxxxZABCDE; where "Y" is B, F. H, SunEdison P, R, or Z; "Z" is 0 or 4; "A" Is B, C, D, E, H, I, J, K, L, M, or N; "B" is B or W; "C" Is A or C; "D" is 3, 7, 8, or 9; and "E" is 0, 1 or 2. Modules with 35, 38, 40, 46, or 50mm frames and model identifiers OPTxxx-AA-B-YYY-Z Suniva or MVXxxx-AA-B-YYY-Z; where "AA" is either 60 or 72; "B" is either 4 or 5; "YYY" is either 100.101,700,1 BO, or 1 B7; and "Z" is blank or B. Modules with standard (G3 or G4) or In%isiMount (G5) 40 and 46mm frames with model Identifier Sunpower SPA-Zb-xxx-YY; where "Z" is either A, E, P or X; "b" can be blank, 17, 18, 19, 20, 21, or 22; and "Wean be blank, NE, BLK, COM, C-AC, D-AC, E-AC, BLK-C-AC, or BLK-D-AC. Sunpreme modules with 35 and 40mm frames and model Identifier SNPM-AxB-xxxYzz; where Sunpreme "A" can be G or H; "Y" can be blank or T; and "zz" can be blank, 413B, SM or 4BB SM. Frameless modules with model Identifier SNPM-GxB-xxxZZ; where "ZZ" can be blank, 413B, SM or 4BB SM. Sunspark Modules with 40mm frames and model identifier SYY-xxZ; where "W" can be MX or SM,, and "Z" can be P or W. Suntech Vd, Vern, Wdb, Wde, and Wd series modules with 35, 40, or 50mm frames. Talesun Modules with 35 and 40mm frames and model identifier TP6yyZxxx-A; where "yy" can be 60, 72, H60 or H72; "Z" can be M, or P; and "A" can be blank, B, or T. Modules with 35, 40 or 46mm frames and model identifier TSM-xxxYYZZ; where WY" is PA05, PCO5, P005, PA14, PC14, PD14, PE14, or DD05; and "ZZ" is blank, A, A.05, A.08, A.10, A.18, .06, Trina .08, .10, .18, .0813, ,18D, 0.82, A.082(II), .002, .00S, 05S, 08S, A(II), A.08(II), A.05(11), A.10(11), or A.18(II). Frameless modules with model identifier TSM-xxxW; and "YY" Is either PEGS, PEG5.07, PEG14, DEG5(11), DEG5.07(II), or DEG14(II). Winaico Modules with 35 or 40mm frames and model identifier Wsy-xxxz6; where "y" is either P or T, and ""z"" is either M or P. Yingli Panda, YGE, and YGE-U series modules with 35, 40, or 50 mm frames. 020194RONRIDGE; INC. VERSION 2.0' _ FLUSH MOUNT INSTALLATION,MANUAL-13 //r IRONRIDGE FlashFoW Installation Features The Strongest Attachment in Solar IronRidge FlashFoot2 raises the bar in solar roof - protection. The unique water seal design is both elevated and encapsulated, delivering redundant layers of protection against water intrusion. In addition, the twist -on Cap perfectly aligns the rail attachment with the lag bolt to maximize mechanical strength. Twist -On Cap FlashFoot2's unique Cap design encapsulates the lag bolt and locks Into place with a simple twist, The Cap helps FlashFoot2 deliver superior structural strength, by aligning the rail and lag bolt in a concentric load path. Single Socket Size A custom -design lag bolt allows you to install FlashFoot2 with the same 7l16" socket size used on other Flush Mount System components. Three -Tier Water Seal FlashFoot2'a seal architecture utilizes three layers of protection. An elevated platform diverts water away, while a stack of rugged components raises the seal an entire Inch. The seal is then fully-encapuslated by the Cap. FlashFoot2 is the first solar attachment to pass the TAS-100 Wind -Driven Rain Test. Water -Shedding Design An elevated platform diverts water away from the water seat. I— 1, f I r�' I Benefits of Concentric Loading Traditional solar attachments have a horizontal offset between the rail and lag bolt, which introduces leverage on the lag bolt and decreases uplift capacity. FlashFoot2 is the only product to align the rail and lag bolt. This concentric loading design results In a stronger attachment for the system. Testing & Certification Structural Certification OA Alignment Markers Quickly align the flashing with chalk lines to find pilot holes. l@ Rounded Corners Makes it easier to handle and insert under the roof shingles. OC Reinforcement Ribs Help to stiffen the flashing and prevent any bending or crinkling during installation. 1200 �.FloehFaot2 t000 �,. Boo ` FWehFoot V 4'Loedln9 Competitor p - 600 m 400 Y Law-Coet Competitor j 200 0 1 2 Rail -to -Lag Offset (in) Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7. Water Seal Ratings Water Sealing Tested to UL 441 Section 27 "Rain Test" and TAS 100-95 "Wind Driven Rain Test" by Intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings. 3 2016 imnRidge, lno-Allrights reserved. Visit www.imnridge.coni or call'1-900-M-9523 for more Information. Version 1.0