Loading...
HomeMy WebLinkAboutPROJECT SUMMARYDIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 SITE PLAN PV-3 SINGLE -LINE DIAGRAM PV-4 SAFETY LABELS MODULE DATASHEET ARRAY WIRING BOX DATASHEET X Z a CL ARRAY WIRING BOX DATASHEET INVERTER DATASHEET MOUNTING SYSTEM DATASHEET MOUNTING SYSTEM ENGINEERING LETTER UL 2703 GROUND AND BONDING CERTIFICATION ANCHOR DATASHEET PROJECT DETAILS PROPERTY OWNER ROGER TRAMS PROPERTY ADDRESS 4100 MCCARTY RD, FORT PIERCE, FL 34945 US APN ZONING RESIDENTIAL USE AND OCCUPANCY CLASSIFICATION ONE -OR TWO-FAMILY DWELLING GROUP (GROUP R3) AHJ COUNTY OF ST. LUCIE UTILITY COMPANY FLORIDA POWER 8 LIGHT CO ELECTRICAL CODE 2014 NEC (NFPA 70) FIRE CODE 2015 NFPA 1 CONTRACTOR INFORMATION COMPANY CORONADO SOLAR LICENSE NUMBER CVC56809 (STATE CERTIFIED SOLAR CONTRACTOR) ADDRESS 3001 CEDORA TER 3001 CEDORA TERRACE, SEBRING, FL 33870 PHONE NUMBER (863) 381-6083 CONTRACTOR SIGNATURE 00091e 00091e �l� VON %rrAQW ; P''N. SETBACK iEn, 'rRONT .ri:CrrvG Cliis SIDS RCA �rli iI Li I FILE Copy ST.LUCIE COUNTY PLAN REVIEW BLDG: DATE' ELEC /' DATE_; 17 PLUMB: DATE: MECH. DATE: Map data 02019 1 l_ 1 PLOT PV-1 SCALE: NTS •o � v - � --rgrrrlC� 513 .. 509b � D n - yyl 1 U° a. 713 IoidianlRiver l Stat'ct.511Cge 91 t _ _ %; d '`Fort Pierce .. South an s ® a 128 OhE�ad im ]� .. � 4 �:; r�hite City , / '7 F 1 �-� .• J Map data 02019 2 LOCALE PV-1 SCALE: NITS RECEIVED GAT 16 _019 SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION OF A PHOTOVOLTAIC POWER SYSTEM. SOLAR PANELS WILL BE RACKED USING A PREENGINEERED RACKING SYSTEM. THE RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION. THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN AWAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS, DIMENSIONS, AND DETAILS IN THIS DOCUMENT. SYSTEM DETAILS NEW GRID -INTERACTIVE DESCRIPTION PHOTOVOLTAIC SYSTEM WITH NO BATTERY STORAGE DC RATING OF SYSTEM 13,680W AC RATING OF SYSTEM 11,020W AC OUTPUT CURRENT 46.DA INVERTER(S) 38 X ENPHASE IQ7PLUS-72-2-US MODULE (HH(ELIENE72M360 NCH OF 9107PLUS-72-2-US ARRAY WIRING MVERTERS 2 BRR NCH OF 10 Q7PLU5 72-2-US MII)CROINVERTERS INTERCONNECTION DETAILS POINT OF CONNECTION NEW SUPPLY SIDE AC CONNECTION PER NEC 705.12(A) UTILITY SERVICE 1201240V 14) SITE DETAILS ASHRAE EXTREME LOW 0°C (32°F) ASHRAE2%HIGH 33°C(91°F) CLIMATE DATA SOURCE VERO BEACH MUNICIPAL AIRPORT (KVRB) WIND SPEED 160 MPH (ASCE7-10) RISK CATEGORY II WIND EXPOSURE CATEGORY B GROUND SNOW LOAD ` ure Geghm, Prg R FiIn9 I P-125384 ,111, r°ooao©oIvwra/nAl.. o LLJ I- Cl� LU J 0 0 LW j In 0 in y J Q LU U W O o- o F- d 0 LL SCANNED BY St. Lucie County iTt Pv_ l N GENERAL NOTES P-125384 orooado r^'""�� usmmo omos W H U) In - .M.,. Lu r� M u- U U A NN C) t.1.. J W O o a U) O F- LL CD 1 SITE PLAN PV-2 SCALE: 1" = 20' SITE PLAN DOG ID: 125384.156305-1 DATE:10/14119 CREATOR: D.M. REVIEWER: REVISIONS PV-2 EQUIPMENT LIKELY TO BE WORKED UPON WHILE 1 ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26. 2 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL 3 EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. + + PV MODULE - PM1-18 j -� 36OW MICROINVERTER oa I I 0® L9IN �91N Q© PM19-01]r+ - PV MODULE j+ 36OW MICROINVERTER IQQ 91-9 j L3 Z�S 'Ea �10M Q© r -J I i-JUNCTION BOX L--�kOAA J81 B2 � -lJ AC COMBINER �I --� C1 r-- MODULES REF. QTY. MAKE AND MODEL I PMAX I PTC I IBC I IMP I VOC VAiP TEMP. COEFF.OFVOC FUSE RATING PM738 1 38 HELIENE 72M360 360W I 326W I 9.71A I 9.73A I 48.1V 39.N I-0.149VPG (-0.31°[i°C) 75A INVERTERS QTY AC MA%OCPD RATED MAX OUTPUT MAXINFUT MAX WPUi CEC WEIGHTED REF, MAKEANDMODELII VOLTAGE GROUND RATING POWER CURRENT CURRENT VOLTAGE EFFIGENCV 1138 3B ENPHASE IQ7PLUS-72.2115 240V UNGRD NDE _ 290hy 1.2A ISAA 60V 97A96 PASS-THRU BOXES AND COMBINERS REF. I OTY. I MAKEANOMODEL RATEDCURRENi MAX RATED VOLTAGE JB1-2 2 SOIADECK 079M WITH 01612 KR OR EQUIV.30A 24DYAD /fi00VOC C1.2 2 1 ENPHASE IO COMBINER 3 0 R EQUIV. VA I240VAC PANT I 1 I GENERIC GEN-ACCOMENER OR EQUIV. 2DOA I 240VAC DISCONNECTS I OCPDS JUNCTION BOX NEFDn' MAKEANDM,ODEL I RATEDCURRENT I MAX RATED VOLTAGE ftEF. Qtt. RATED CURRENT MAXVOLTAGE SW1 7 EATON DG222NRB OR EQUIV. BOA 240VAG C81-2 2 75A 240VAC C2 ACCOMBINER PANT L - - - - - - - - - - - GOA - PV SYSTEM DISCONNECT r---------- swi I 60A I B I I (200A MSP W1200A MCB) AA I I I � LOADS r-------------- - _l= IJTIDTY METER AC lid 240112OV 4, 3W GEC SYSTEM SUMMARY _ BRANCHESI BRANCHES2 BRANCHI BRANCH BRANCHI BRANCH2 TERS PER BRANCH 9 9 10 10 000RRENT JSRATED 10B9A 10.89A 121A 12.1A COUTPUT 2,610W 2,61OW 2,900W 2,9WW AC OUTPUT 2,85OW 2,85OW 3,167W 3,167WY STC POWER 6ABOW 7,200W YPIC POWER B877W 6,530W CCURRENT 2ZA 24A AX ACPOWE2 OUTPUT ,220 5W g800W ERATEDAC POWER OUTPUT 5220W 1 5,80OW YSTC POWER 13,680W YPTCPOWER 12,407W ACCURRENT 46A AXAC POWER OUTPUT 11,020W ERATEDAC POWER OUTPUT I 1ZO35W CIE 2 2OA 240VAC CBS I 7 I 30A 240VAC C86 i 1 I 35A 240VAC FI-2 2 1 60A 240VAC NOTES THE DC AND AC CONNECTORS OF THE USTED ENPHASE IQ7PLUS-72-2-US CONFORM TO 0 NEC 690.11(E) REQUIREMENT THAT INVERTERS INCLUDE DISCONNECTS FROM ALL SOURCESOFPOWER MICROINVERTER BRANCH CIRCUITCONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQMICROWVERTERS. ® THEYARE ROHS, OIL RESISTANT, AND UV RESISTANT. THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/DAVNY2 DRYA9E7 AND CERTIFIED TO UL3003 AND UL 9703. THE CABLES DOUBLE INSULATED RATING REQUIRES NO NEUTRAL OR GROUNDED CONDUCTOR UNGROUNDED SYSTEM DC CONDUCTORS SHALL BE COLORCODED AS FOLLOWS. DC ® POSITIVE SHALL BE RED (OR MARKED RED) AND DC NEGATIVE SHALL BE BLACK (OR MARKED BLACK) ALLMETAL ENCLOSURES,RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYIP METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC Q 250.4(B) AND PART III OF NEC ARTICLE 250 AND EQUIPMENT GROUNDING CONDUCTOR SHALL BE SIZED ACCORDING TO NEC 69OA5. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO 690.47(B)AND 250.169. THE DC GROUNDING ELECTRODE SHALL BE SIZED ACCORDING TO 250.166 AN ADDITIONAL ARRAY GROUNDING ELECTRODE SHALL BE INSTALLED IN ACCORDANCE WITH NEC SECTIONS 260.52 AND 250.54 UNLESS THE ARRAY STRUCTURE ISSUITABLETO ® SERVEAS AGROUNDING ELECTRODE ASPER NECSECTION 25U, THE LOAD SERVED BY THEARRAYIS INTEGRAL WITHTHEARRAY, OR THE PREMISES EXISTING WIRING ELECTRODE IS LOCATED WITHIN 6FT, AS PER NEC SECTION 690.47(0) ® MAX DC VOLTAGE OF PV MODULE IS EXPECTED TO BE 5I.BVAT O°C(0°C-25°C)X -0.I49V1C • 48.1 V = 61. M. PV SYSTEM DISCONNECT SHALL BE AVISIBLE KNIFE -BLADE TYPE DISCONNECT THAT IS B ACCESSIBLE AND LOCKABLE BY THE UTILITY. THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF UTILITY METER POINT-OFCONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT, AT A ® LOCALLY -APPROVED CONNECTION POINT, USING LOCALLY -APPROVED METHODS AND HARDWARE, IN COMPLIANCE WITH NEC 705.12(A), CONDUCTOR AND CONDUIT SCHEDULE WfELECTRICAL CALCULATIONS CURRENTLARRYWO FAIL COIN. MAKDIRFENT ME DEBATED TERM AAP.IDTEAM ttPKx CmOIJCTOR CIX URIQULE C IJC7XXZN CCPD EDE TEMP. CORK FACTOR FACi0.4 WRRBIT Du%) FP A. AAff. TEMP. FAIWG TF1dP. RADNG WNWRIMUE I I IOAWGTHWNL O.NCAREXIE E 4 15A SAWGTHWN2, Q76I53C) 02 lam 1311A 40A 24Ar7FC 40.A WPPER STEEL COPPal 2COPPER AWGT1M1+2, 0.15-DI0. FLEXBLE 4 15A BAWGTHWNQ 0.T6153-C) 0.B 10A9A 13biA 40A R4iN 4M STEEL TA1PP� 3AWG O.7SDSLMMC 2 MA SAWl1�M�, 0.]6I55°OT IA 21.]M 2123A 4M 30.4A MA 4AWGTHvM1'N2, UY DA SUXIBE 4 BAWOIHWNS. O.)BIS]°cT 04 ILIA 15.1M dM 2131A 4M COPPER STEEL COPFEiR 5AWGTHAT42, 4'�o� Oi4DAME 4 2M SAYA9BWiNy ax(5 C) CA ILIA ISAM 4M 24M 4M COPPER STE9 COPPER 6AM THN -2. 0.75.OLALEMC 2 35A SAINT W cn IA°C) IA 242A W25A 55A 41.M SOA COPPER1 91 2. PDALFMC 2 IOU S Z 0.95(33°C) fA 4S9BA ST.4IA IM TIN 6M WP COFf'� BWOPPE112 1'DALFMC 2 MX2 BAWGTXYW?, D%G3-C) fA am 5]ATA ]S4 ]2A 71C fiM COPPER WPPER SINGLE -LINE SCALE: NTS T103D WEWHANBEENCRFATEOFORMEPIIRWlSEOFDESCR®INGTHEDESIGNWAPROPOSEDMOTOVOLTXCN SYSTEMY4MENWGHDETMLTODEMONSTRATEWMPLUNCEWIMA1 APPLICABLE COOESANO AEGUTATIONS.THE DOCUMENTSHOULONOTBE PELTED UPONASA VMTRUTE FOR FOLLOWMGMAMIFACNRERWSTPLMRW MAUS. WSTAQERSHM1 MTALLAII EOURMENTIN ACCIXROANCEWRH MMNFACNRFAMSTALIARW kANUALS.NOTHING IN iHISDOCVMENi6HDMBEPl1ERPREfEDWAWAYTXAT INFARpE3TXEWSTPIY;(TONS IN MAMIFACNRERMSTAWTKKIMPMIII3. GENERAL ELECTRICAL NOTES HAS 24-HR UNRESTRICTED ACCESS TO ALL 1 JUTILITY PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 IMODULES CONFORM TO AND ARE LISTED UNDER UL 1703. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS 3 SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.8 (D). CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE 4 SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.8 (C). GROUNDING NOTES ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE 1 REQUIREMENTS OF NEC ARTICLES 250 & 690 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED 2 GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY -IN LUGS. INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS 3 BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. 4 ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A 5 VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) 6 SHALL BE A MINIMUM SIZE #BAWG WHEN INSULATED, #6AWG IF BARE WIRE. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED 7 ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE GROUNDING AND BONDING CONDUCTORS, IF INSULATED, 8 SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER P-125384 ,„y-I.-�4yfURFAdO n\eo omM omox mi W I- co O 0 1- f Nf C) W im U SINGLE -LINE DIAGRAM PROJECT ID: 125384 DATE: 10/14119 CREATED BY: D.M. CHECKED BY: I REVISIONS I PU JB1 -TRANSITION BOX EACH DEVICE WHERE ENERGIZED, SOLADECK 0799-5 WITH 01612 KIT) O UNGROUNDED CIRCUITS MAY BE EXPOSED OO DURING SERVICE. (JR1, JB2) 1111AD►IWf� JB2-TRANSITION BOX SOLADECK 0799-5 WITH 01612 KIT)G wim , 4Dalfj U . ARE UNG OO NEC 690.35(F) Cl -AC COMBINER ENPHASE IQ COMBINER 3 O C2 - AC COMBINER ENPHASE 10 COMBINER 3 O OAC SOLAR DISCONNECT(SW7) PHOTOVOLTAIC AC DISCONNECT OEACH DISCONNECTING MEANS FOR O AC DISCONNECT (SW7) PHOTOVOLTAIC EQUIPMENT (JB1, JB2, Cl, C2) ! WARNING I ELECTR ^ EK HAZAPD DO NOT TOUGH E INA -S. TE MINALS OP BOT LI E AND GA S10ES MAY BE EN RGIZ D IN THE OPEN P.O5ITION. NEC 690.17(E) OSEE NOTE NO.5 (SW7) NEC 690.66(C) AND IFC605.11.1 OAC DISCONNECT(CB5 IN PANT) O AC DISCONNECT(CB6 IN PANT) SW1-DISCONNECT EATON DG222NR8 OO O O MAXIMUM AC OPERATING CURRENT: 21.8A MAXIMUM AC OPERATING CURRENT:24.2A MAXIMUM AC OPERATING VOLTAGE: 240V MAXIMUM AC OPERATING VOLTAGE: 240V PANT -AC AGGREGATION PANEL MODEL NOT SPECIFIED NEC 690.54 NEC 690.54 O O O O MSP - MAIN SERVICE PANEL SQUARE D O MAXIMUM AC OPERATING CURRENT:46.OA MAXIMUM AC OPERATING VOLTAGE: 240V NEC 690.54 OANY AC ELECTRICAL PANEL THAT IS FED BY BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (SW1, PANT, MSP) OAC COMBINER PANEL(PAN1) LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2014 NEC AND 2015 NFPA 1 WILL BE INSTALLED AS REQUIRED. LABELS, WARNING(S) AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES THAT DANGER, WARNING, AND CAUTION SIGNS USED THE STANDARD 2 HEADER COLORS, HEADER TEXT, AND SAFETY ALERT SYMBOL ON EACH LABEL. THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50% TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH NEC 110.21(B). A PERMANENT PLAQUE OR DIRECTORY SHALL BE 3 INSTALLED PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH NEC 690.56(B). WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN SHALL BE INSTALLED AT EACH DC PHOTOVOLTAIC SYSTEM 4 DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF ALL AC AND OC PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IN THE BUILDING, IN ACCORDANCE WITH NEC 690.4(H). LABEL(S) WITH MARKING, 'PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN; SHALL BE LOCATED 5 AT POINT -OF -INTERCONNECTION ORAT MAIN SERVICE DISCONNECT THE LABEL SHALL HAVE 318° TALL LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A RED BACKGROUND P-125384 w M -Coronado a \r SAFETY LABELS PV-4