HomeMy WebLinkAboutPRODUCT APPROVALSCANNED
BY"
St. Lucie County rn' _ F L olmn;
t
�a
BCIS Hpm! faq In 'User Registratlln I Hat Topie ' submi[SUNurge sts[se Fads i Publiotions Connct Us BCls site Map Wka search
bpr
a
��-� Product Approval
USER: Public User
Pmdutt Approval Menu> Qmdud or Aoellmtkn search> ApolkaUnn Lilt Appfl.Uon Doran RECF-WED
FL # FL27402-R1 V
Application Type Revision
Code Version 2017 OCT 16 C U!
Application Status Validated
ST. Lucie County, Pennitting
Comments
Archived
Product Manufacturer Carports Anywhere
Address/Phone/Email 10858 S.E. County Road 221
Starke, FL
(352)468-1116
bodom@arportsanywhere.com
Authorized Signature Brendle Odom
bodom@mrportsanywhere.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Structural Components
Subcategory Roof Deck
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer _
= Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Terrence E. Wolfe
the Evaluation Report
Florida License
PE-44923
Quality Assurance Entity
PRI Construction Materials Technologies, I.I.C.
Quality Assurance Contract Expiration Date
06/23/2023
Validated By
Brian Jaks, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Itl4YQtk�3tlUI�[9RSLS[KfiI1LF1iGLllTf1
Standard
ASTM E 1592
FM 4471
Product Approval Method Method 1 Option D
Year
2005
1992
Date Submitted 08/08/2019
Date Validated 08/09/2019
Summary of Products
FIL tt
Model, Number or Name
Description
27402.1
'Hampton Rib Roof Panel
Hampton Rib Roof Panel over Open Framing
Limits of Use
Installation Instructions
Approved for use in HVHZ:. No
Approved for use outside HVHZ: Yes
FL27402 RI IT Hampton Rib Roof Panel over open
framing.odf
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +46.9 psf/-57.3 psf
Created by Independent Third Party: Yes
Other: See evaluation report for various design pressures
Evaluation Reports
Install per Manufacturer's details. Not for use In HVHZ Zones.
FL27402 RI Arz Hampton Rib Roof Panel over open
hraminp.odf
Created by Independent Third Party: Yes
00
content .Us :: 2601 Blair Stane Road. nlmhaeta FL 3P_99 Phone: 850-487,1824
The State If Rorda Is an AA/I employee. Sbnyout 2001-2013 State of Florida.:: W pv Statement ::Accettibllity Statement:: Refund Statement
under Florida law, ema0 addresses are public records. nyou do not want your emall address reieated In response to a public -newels Mavesp do not send eie
mall to this entity. innead, wntaR the onto by phone or by traG0pn31 mall. IF you have any questions, please wntad 850.487.1395.'Pumuant to Sell
455.275(1), Florida Statutes. enedhe Odaber 1. 2012. thome e, Brensed enter Chatter 455. e5. must eneide the Denanment with an email addreta it the
Department with an
Product Approval Adepts:
® L!7== :crq
Credit Card
Safe
a
Force Engineering & TestingInc.
19330 Pbl..d Ddvc
H.blgTX 77338
Product Evaluation Report
CARPORTS ANYWHERE
Hampton Rib Roof Panel over open framing
Florida Product Approval # 27402.1 RI
Florida Building Code 2017
Per Rule 61G20-3
Method: I—D
Category: Structural Components
Subcategory: Roof Deck
Compliance Method: 61G20.3.005(1)(d)
NON HVHZ
Product Manufacturer:
Carport Anywhere
10858 S.E. County Road 221
Starke, Florida 32091
Engineer Evaluator:
Terrence E. Wolfe, P.E. # 44923
Florida Evaluation ANE ID: 1920
Validator•
Brian Jaks, P.E. #70159
Contents:
Evaluation Report Pages 1-4
C E'E,''O'��i
Q-e'V 1 C E li S F,<,n.
[ + NO.499� /
A' STATE OF
� 4
0�0.n. At OR19p..•�4,
m.crnae. I FS ' S . i C
rmr ��i OH "trial,t
FL# 27402.1 RI August 8, 2019
Force Engineering & Testing Inc.
19530 Ramblcwood Ddve
HumbkJX 7733a
Compliance Statement: The product as described In this report has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2, 1504.7.
Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Roof Panel, 36" Wide, through fastened
structural roof panel. Structural Application.
Panel Material/Standards: Material:
26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 50
29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80
Conforming to Florida Building Code 2017 Section 1507.4.3. Optional paint finish.
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2017, Section 1507.4.3.
Panel Dimension(s):
Thickness: 26 Ga.: 0.0185" min. order thickness
29 Ga.: 0.0142" min. order thickness
Width: 36' maximum coverage
Rib Height: Y" major rib at 9" O.C.
Panel Rollformer: MRS Metal Rollforming Systems
Panel Fastener:
#12-14 x '/." HWH SD#3 with 14mm neoprene bonded washing or approved
equal.
Corrosion Resistance: Per Florida Building Code 2017, Section 1507.4.4.
Substrate Description:
Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel
framing, or Minimum 18 Ga. (Grade 50) Steel framing. See Table A & B for steel
gauge. Framing must be designed in accordance w/ Florida Building Code 2017.
Allowable Design Pressures:
Table "A" 26 Ga. Hampton Rib Roof Panel
Maximum Design Pressure:
-57.3 psf
-72.9 psf
-67.7 psf
a46.9 psf
+54.7 psf
Panel Fastener Pattern:
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2-1
Panel Span:
5'-0- O.C.
4'-0- O.C.
4'-0" O.C.
5'-0" O.C.
4'-0' O.C.
Substrate:
Min. 14 Ga.
Steel Framing
Min. 14 Ga.
Steel Framing
Min. 18 Ga.
I Steel Framing
Min. 18 Ga.
Steel Framing
Min. 18 Ga.
Steel Framing
-Design Pressure Includes a Safety Factor= 2.0.
s3t.q Etj tr714-
%� E .....
No. 419� /
A*:, — A.
STATE OF
+PO,n • JDL O RI 91`,
sssw �i fy; •.
0A6 �I S - . •Nt
FYfA �1110
HIt1pSo
FL# 27402.1 Rl
August 8, 2019
Force Engineering & Testing Inc.
19530 Bambicwaod Drive
HumblgTX 77338
Table "B" 29 Go. Hamotan Rib Roof Panel
Maximum Design Pressure:
-57.3 psf
-150.9 psf
a39.0 psi
1143.1 psf
Fastener Pattern:
6"_3"-6"_3"_6"-3"-6"
6"-3"-6"-3"-6"-3"-6'
6"-3"-6"_3•-6"_3•_6"
6"_3„-6"_3"_6"_3,-6„
Fastener Spacing:
4'-G" C.C.
2'-0" O.C.
4'-W O.C.
2'-W O.C.
Substrate:
Min. 16 Ga.
Steel Framing
Min. 36 Ga.
Steel Framing
Min. 16 Ga.
Steel Framing
Min. 16 Ga.
Steel Framing
*Design Pressure Includes a Safety Factor = 2.0.
Code Compliance: The product described herein has demonstrated compliance with
The Florida Building Code 2017, Section 1504.3.2, 1504.7.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2017, as relates to Rule 61G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
• ASTM E 1592-05 (2012) Test method for structural performance of
sheet metal roof and siding systems by uniform static air pressure
difference
• FM 4471-92- Foot Traffic Resistance Test
Reference Data: 1. ASTM E 1592-05 (2012) Test
Force Engineering &Testing, Inc. (FBC Organization #TST-5328)
Report No. 667-006OT-18A-E, 667-0061T-18A-D
2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 667-0O60T-18F, 667-0061T-18E
3. Certificate of Independence
By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc.
(FBC Organization H AN E ID: 1920)
Test Standard Equivalency: The FM 4471-10, Foot Traffic Resistance test standard is equivalent to
FM 4471-92.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005 (3) for
x%,x1•N C1E1E tr,zj�i
F...E W i
Q-.,t' tCE NS
No. 440
P,• STATE OF
�i0^` • �'Z O RICALL
D 1`.•?���
FL# 27402.1 RI
August 8, 2019
�y
Force Engineering & Testing Inc.
19530 Ramblewood Ddve
Humble,7X 77338
manufacturing under a quality assurance program audited by an approved
quality assurance entity..
Minimum Slope Range:
Minimum Slope shall comply with Florida Building Code 2017, including Section
1507.4.2 and in accordance with Manufacturers recommendations. For slopes
less than 3:12, lap sealant must be used in the panel side laps.
Installation:
Install per manufacturer's recommended details.
Insulation:
Manufacturer's approved product (Optional)
Roof Panel Fire Classification:
Fire classification is not part of this acceptance.
Shear Diaphragm:
Shear diaphragm values are outside the scope of this report.
Design Procedure:
Based on the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2017 for roof cladding
wind loads. These component wind loads for roof cladding are compared to the
allowable pressure listed above. The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover. Support framing must be in compliance with Florida Building Code 2017
Chapter 22 for steel, and Chapter 16 for structural loading.
0�3s`ptC E 1E 1i
J Q F •' ko �i
CENSF<�.
No. 40
s._A7F�
STATEOF
w. AL 0RI D A.
msarw �i FS • 't
FL# 27402.1111
August 8, 2019
26 GA. HAMPTON RIB FASTENER PATTERN 2-1-2-1
`- #12-14 x 3/4' HIM S03 W/ 14MIA BONDED NEOPRENE HASHER
29 GA. HAMPTON RIB FASTENER PATTERN 6"-3"-6"-3"-6"-3"-6"
G' 3' 6' 3" 6" 3' 6. 3'
#12-14 • 3/4' IRVH SU3 YI/ 14M1A BONDED NEOPRENE HASHER
SMOo1FIG1m!
C.OJL
92am
e.
NO.44923
A 40QJ8TAA OF _; i L
August 8, 2019
9/20/2018 Florida Building Code Online
Y v Pi'�•F�-, S��"71{ �td� t yP >e s�+Y�Y � I'kPR'Y. �a,ra.,e.
d -- N
BCIS Home I Login I user Reglsuaaon I Hot Topla Submit Surcharge I Stats BFadts I Publleabare contact Us BOSSIte Map I Unks I Seard
wI IFlAonda
r �' \ :6 `�-9/ Product Approval
Uf1�JJ t�i �� useR: Pubuc user
:...�:p
PmduR Aoomval Menu > QmduR or Application Search > QpplicaHon llsb Application eetall
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Small
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL27403
New
2017
Approved
Carports Anywhere
10858 S.E. County Road 221
Starke, FL
(352) 468-1116
bodom@carportsanywhem.com
Brendle Odom
bodom@carportsanywhene.com
Structural Components
Structural Wall
SCANNED
BY
St. Lucie County
Evaluation Report from a Florida Registered Architect or a Licensed Florkh
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Terrence E. Wolfe
Evaluation Report
Florida License PE-44923
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 06/13/2023
Validated By Gary Hartman, P.E.
v Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL27403 RO COI Letter of Certification.odf
Standard
ASTM E 1592
ASTM E 330
Year
2005
2002
https9/www.8oddabuilding.org/pdpr app d8.aspx?pamm=wGEVXQwtDquHOE2Ywe%2bOsAuSaR1O%2fsNjldto6lC%2f%2bLV98RAA3xJ6YAa/o3d%3d 1/2
9/20/2018
Florida Building Cade Online
C
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option D
06/18/2018
06/19/2018
06/27/2018
08/15/2018
Summaloi,sixtProducts
FL #
Model, Number or Name
Description
27403.1
Hampton Rib Wall Panel
Hampton Rib Wall Panel over open Framing
Limits of LUs
Installation Instructions
r use In HVHZ: No
Approved for use outside HVHZ: Yes
FL27403 RO II Hampton Rib Wall Panel Secured.pdf
Verified By: Terrence E. Wolfe, P.E. 44923
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-57.3 psf
Evaluation Reports
Other: See Evaluation Report for various Design Pressures.
FL27403 RO AE Hampton Rib Wall Panel Secured.odf
Created by Independent Third Party: Yes
Install per Manufacturer's Details. Not for use in HVHZ Zones.
27403.2
Rest -Lap Siding Wall Panel
Resi-Lap Siding Wall Panel over open Framing
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
FL27403 RO It Resi-Lao Wall Panel secured.Ddf
Verified By: Terrence E. Wolfe, P.E. 44923
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +40.0 psf/-37.0 psf
Evaluation Reports
Other: +40.0 psf at 4'-C" o.c. -37.0 psf at 4'-0" o.c. Install per
FL27403 RO AE Resi-Lao Wall Panel secuned.pdf
Created by Independent Third Party: Yes
Manufacturer's Details. Not for use in HVHZ Zones.
Dach Npat
Contact Us :: 7601 Blair Stone Road, Tallahassee K 32399 Phone: 8504197-1824
The State of Florida Is an AAjfC employer. Cowdeht 2007-2013 State a Florida.:: PrivaN Statements': Accessibl0ty Statement :: Refund Statement
Under Florlda law, email addresses are public records. if you do not want your e-mall address released In response to a public -records request, do not send elecoonlh
mall to this emlty. Instead, conmet the office by phone or by traditional mall. If you have arty quetlons, please contact 850.497.1395.'Fursuant to section 455.275(1
Florida statutes, effective Comber 1, 2012, licensees licensed under chapter 455, F.S. must pmvlde the Department with an email address If they have one. The emal
provided may be used for official cemmunlca ion with the licensee. However email addresses are public rerord. If you do not wish to supply a personal address, pleas
provide the Department with an email address which can be made avallabie to the public Te determine If you are a 0rensee under Chapter 455, F.S. please click h=
Product Approval Accepts:
M®go td
Credit Card
Safe
httpsYMAvw.floddabuilding.org/pr/pr app dti.aspx7parom-vGEVXQwtDgUHOEZywep/`2bOsAuSaRl O%2fsNjldto6lC%2fa/a2bLV98RAA3xJ6YAPA3d%3d 2I2
FL# 27403.1
Force Engineering & Testing Inc.
195301t=ble cd DAv.
Humblc,TX 77338
Product Evaluation Report
CARPORTS ANYWHERE
Hampton Rib Wall Panel over open framing
Florida Product Approval # 27403.1
Florida Building Code 2017
Per Rule GIG20-3
Method: 2—B
Category: Structural Components
Subcategory: Structural Wail
Compliance Method: SIG20-3.005(2)(b)
NON HVHZ
Product Manufacturer:
Carport Anywhere
10858 S.E. County Road 221
Starke, Florida 32091
Engineer Evaluator:
Terrence E. Wolfe, P.E.044923
Florida Evaluation ANE ID: 19ZO
Validator•
Gary Hartman, P.E. 073227
Contents:
Evaluation Report Pages 1-4
sSS�s,N C E !e rrrrrr.
C ti N
410
•"• STATE OF
°.n . AL O RI 9 A •?�
s..rrmu �i ors •. • 't �
JI�v1e.18, 201a
rForcengineering&Teating Inc.
19530 Aamblowood D.Im
Hvmble,TR77138
Compliance Statement: The product as described In this report has demonstrated compliance with the
Florida Building Code 2017, Sections 1709.2.
Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Wall Panel, 36" Wide, through fastened
structural wall panel. Structural Application.
Panel Material/Standards: Material:
26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 50
29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80
Conforming to Florida Building Code 2017 Section 1405.2.
Panel Dimension(s): Thickness: 26 Ga.: 0.0185" min. order thickness
29 Ga.: 0.0142" min. order thickness
Width: 36" maximum coverage
Rib Height: Y.." major rib at 9" O.C.
Panel Rollformer: MRS Metal Rollforming Systems
Panel Fastener: #12-14 x Y" HWH SD#3 with 14mm neoprene bonded washing or approved
equal.
Corrosion Resistance: Per Florida Building Code 2017.
Substrate Description: Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel
framing, or Minimum 18 Ga. (Grade 50) Steel framing. See Table A & B for steel
gauge. Framing must be designed in accordance w/ Florida Building Code 2017.
Allowable Design Pressures:
Time "A" as Ca ue".,.t"" sob w-n pane!
Maximum Design Pressure:
-57.3 psf
-72.9 psf
'-67.7 psf
+46.9 psf
+54.7 psf
Panel Fastener Pattern:
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2-1
Panel Span:
51-V O.C.
4'-V O.C.
4'-V O.C.
51-W O.c.
Substrate:
Min. 14 Ga.
Steel Framing
Min. 14 Ga.
Steel Framing
Min. 14 Ga.
Steel Framing
Min. 18 Ga.
Steel Framing
Min. 18 Ga.
Steel Framing
-Design Pressure includes a Safety Factor - 2.0.
RM 27403.1
`,t%'JL1111[fr tr'
,%s% I. C E, E
C E N
4,
STATE OF
0 It. IN.
ODA
Ju4%z,18, 201E
LjTesting Inc.
amewood Drive
HumbleaX 77338
Table'R' 29 Ga. Hameten Rib Wall Panel
Maximum Design Pressure:
-57.3 psf
-1503 psf
+39.0 psf
+143.1 psf
Fastener Pattern:
6'-3'-6'3'-6'-3"-6'
6'-3'-6'-3"-6'-3'-6"
6"-3'-6"-3'-6'-3"{'
6"-3'3"-3--6"-3'-6"
Fastener Spacing:
4'-0' me
&-0' O.G
4,-w O.C.
r-cr O.C.
•Design Pressure Includes a Safety Factor= 2.0.
Code Compliance:
The product described herein has demonstrated compliance with
The Florida Building Code 2017, Section 1709.2.
Evaluation Report Scope:
The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2017, as relates to Rule 61G20-3.
Performance Standards:
The product described herein has demonstrated compliance with:
• ASTM E 1592-05 (2012) Test method for structural performance of
sheet metal roof and siding systems by uniform static air pressure
difference
Reference Data:
1. ASTM E 1592-05 (2012) Test
Force Engineering & Testing, Inc. (FBC Organization #TST-5328)
Report No.667-006OT-18A-E, 667-0061T-18A-D
2. Certificate of Independence
By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc.
(FBC Organization # ANE ID: 1920)
Quality Assurance Entity:
The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 614320-3.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Installation:
Install per manufacturer's recommended details.
Insulation:
Manufacturer's approved product (Optional)
Panel Fire Classification:
Fire classification is not part of this acceptance.
vu�rw
onn
cxm
FL# 27403.1
O
E• E ;Y �•i
CE Ngh; t,p:
STATE OF ;
41 ��
Jlwte,18, 2018
q ,,
rlFloEnginef—
rcc Testing Inc.
19530 R=earood Drive
Humble,TX 77338
Shear Diaphragm: Shear diaphragm values are outside the scope of this report.
Design Procedure: Based an the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2017 for wall cladding
wind loads. These component wind loads for wall cladding are compared to the
allowable pressure listed above. The design professional shall select the
appropriate erection details to reference In his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover. Support framing must be in compliance with Florida Building Code 2017
Chapter 22 for steel, and Chapter 16 for structural loading.
FI.# 27403.1
i,
c..... .w
C E N
STATE OF
%a•ALORI.DA
srwrrn �i PS • . 1
ta,%�
Jt l4w 18, 2018
26 GA. HAMPTON RIB FASTENER PATTERN 2-1-2-1
#12-14 x 3/4' HAH SD3 W/ 14MM BONDED NEOPRENE WASHER
29 GA. HAMPTON RIB FASTENER PATTERN 6"-3"-6"-3"-6"-3"-6"
6' _ - 3'_ 6' 3'_ 6' 3' 6' 3'
912-14 x 3/4' NWN SD3 W/ 14MM BONDED NEOPRENE WASHER
raw of Flodd9
p.OA
0 Sam
No. 44923 ".0 %
k G
srar-- oA
IMN18208