HomeMy WebLinkAboutENERGEY EFFICIENCYFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
-Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE ROYALE IMPACT
Builder Name: WYNNE
SCANNED
Street: WYNNE DEV. Q-�
Permit Office: ST. LUCIE COUNTY
BY
City, State, Zip: FT. PIERCE, FL, D lJ7
Permit Number:
St. Lucie County
Owner:
��
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1688.7 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1448.70 ft2
b. Frame - Wood, Adjacent
R=11.0 240.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1720.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1720.00 ft2
6. Conditioned floor area above grade (ft� 1720
b. N/A
R= ft2
Conditioned floor area below grade (ft� 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(155.4 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 275
a. U-Factor: Sgl, U=1.04 115.42 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft2
12. Cooling systems
kBtulhr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtulhr Efficiency
d. U-Factor. WA ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.316 ft.
Area Weighted Average SHGC: 0.285
14. Hot water systems
8. Floor Types (1720.0 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft2
b. Conservation features
EF: 0.970
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.090 Total Proposed Modified Loads: 55.56
PASS
Total Baseline
Loads: 56.16
1 hereby certify that the plans and specifications covered by
Review of the plans and
5TAjE
this calculation are in compliance with the Florida Energy
specifications covered by this
OQTKE
y = O�
Code.
calculation indicates compliance
with the Florida Energy Code.
n+u'•%• :; ::
PREPA D BY:
Before construction is completed
a
DATE:�}-/
this building will be inspected for
compliance with Section 553.908
-
O y
* 9 a
T�
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
J,t,
with the Florida Energy Code.
C'Op WE
OWNER/AGENT: -�
BUILDING OFFICIAL:
DATE: \O
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
9/15/2019 10:17 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE ROYALE IMPA Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1720
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE
Rotate Angle: 135
Street:
WYNNE DEV.
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1720 13760
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 BEDROOM
343 2744 No 0
1
1
Yes
Yes
Yes
2 WIC
63 504 No 0
1
No
Yes
Yes
3 M. BATH
56 448 No 0
1
Yes
Yes
Yes
4 KITCHEN
172 1376 Yes 0
1
No
Yes
Yes
5 BATH
45 360 No 0
1
Yes
Yes
Yes
6 BEDROOM 2
204 1632 No 0
1
1
Yes
Yes
Yes
7 ENTRY
98 784 No 0
1
Yes
Yes
Yes
8 LAUNDRY
42 336 No 0
1
Yes
Yes
Yes
9 GREAT/DINING
528 4224 No 0
1
Yes
Yes
Yes
10 BEDROOM 3
169 1352 No 1
1
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Woad
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
343 ft'
—_
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ft'
____
0 1
0
3 Slab -On -Grade Edge Insulatio
M. BATH 8 ft 0
56 ft'
__
0 1
0
4 Slab -On -Grade Edge Insulatio
KITCHEN 1 ft 0
172 ft'
0 1
0
5 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
45 ft'
0 1
0
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 42.6 ft 0
204 ft'
___
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 6.3 It 0
98 ft'
—�
0 1
0
9/15/2019 10:17 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
'
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 112
-_
0
1
0
9SIab-On-Grade Edge Insulatio GREAT/DINING 48 ft
0
528 ft2
___
0
1
0
10SIab-On-Grade Edge Insulatio BEDROOM 3 13 ft
0
169112
--
0
1
0
ROOF
_ /
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Gable or Shed Metal 1813 ft2
286 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1720 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) BEDROOM
30
Blown
343 ft2
0.1
Wood
2
Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3
Under Attic (Vented) M.BATH
30
Blown
56 ft2
0.1
Wood
4
Under Attic (Vented) KITCHEN
30
Blown
172 ft2
0.1
Wood
5
Under Attic (Vented) BATH
30
Blown
45 11:2
0.1
Wood
6
Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7
Under Attic (Vented) ENTRY
30
Blown
98 ft2
0.1
Wood
8
Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9
Under Attic (Vented) GREAT/DINING
30
Blown
528 11:2
0.1
Wood
10
Under Attic (Vented) BEDROOM 3
30
Blown
169 ft2
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Below
0
1
N=>SE
Exterior Concrete Block - Ext Ins®EDROOM
4.1 9
0 8
0
72.0 ft2
0
0
0.4
0
2
S=>NW
Exterior Concrete Block - Ext Ins®EDROOM
4.1 29
0 8
0
232.0 ft2
0
0
0.4
0
3
W=>NE
Exterior Concrete Block - Ext Ins®EDROOM
4.1 14
0 8
0
112.0 112
0
0
0.4
0
4
S=>NW
Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 112
0
0
0.4
0
5
N=>SE
Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
6
N=>SE
Exterior Concrete Block - Ext Indf1EDROOM 2
4.1 14
0 8
0
112.0 112
0
0
0.4
0
7
NE=>S
Exterior Concrete Block - Ext Indf1EDROOM 2
4.1 2
10 8
0
22.7 ft2
0
0
0.4
0
8
E=>SW
Exterior Concrete Block - Ext InfiffDROOM 2
4.1 9
0 8
0
72.0 ft2
0
0
0.4
0
9
SE=>W
Exterior Concrete Block - Ext Ind]EDROOM 2
4.1 2
10 8
0
22.7 ft2
0
0
0.4
0
10
S=>NW
Exterior Concrete Block - Ext InfiEDROOM 2
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
11
NE=>S
Exterior Concrete Block - Ext Insul ENTRY
4.1 1
5 8
0
11.3 ft2
0
0
0.4
0
12
E=>SW
Exterior Concrete Block - Ext Insul ENTRY
4.1 5
0 8
0
40.0 11:2
0
0
0.4
0
9/15/2019 10:17 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R406-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Below
0
_ 13 S=>NW Exterior Concrete Block - Ext InsdIAUNDRY 4.1 6 0 8
_ 14 N=>SE Exterior Concrete Block - Ext InsGi REAT/DINT 4.1 28 0 8
15 W=>NE Exterior Concrete Block - Ext InSOREAT/DINT 4.1 20 0 8
16 N=>SE Exterior Concrete Block - Ext Infi EDROOM 3 4.1 13 0 8
17 N=>SE Garage Frame - Wood BEDROOM 3 11 30 8
0 48.0 ft'
0 224.0 ft'
0 160.0 ft'
0 104.0 ft'
240.0 ft'
0 0 0.4
0 0 0.4
0 0 0.4
0 0 0.4
0.23 0.4
0
0
0
0
0
DOORS
# Omt Door Type Space
Storms
U-Value
Ft
Width Height
In Ft In
Area
1 E=>SW Insulated ENTRY
None
.39 3
6 8
20 ft'
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/ Wall
V # Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Overhang
Area Depth Separation Int Shade
Screening
1 W=>NE 3 Metal Low-E Single Yes
2 S=>NW 4 Metal Low-E Single Yes
3 E=>SW 8 Metal Low-E Single Yes
4 N=>SE 14 Metal Low-E Single Yes
5 W=>NE 15 Metal Low-E Single Yes
6 N=>SE 16 Metal Low-E Single Yes
1.04 0.29 N
1.04 0.29 N
1.04 0.29 N
1.04 0.29 N
1.11 0.27 N
1.04 0.29 N
32.4 ft' 1 ft 0 in
6.9 ft' 1 It 0 in
23.2 ft' 1 It 0 in
36.8 ft' 1 It 0 in
40.0 ft' 10 It 0 in
16.2 ft' 1 It 0 in
1 It 6 in Drapes/blinds
1 It 5 in None
1 It 5 in None
1 It 5 in None
1 ft 5 in None
1 It 5 in None
Exterior 5
None
None
None
None
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 300 ft' 300 ft'
30 It
8 ft
11
INFILTRATION
# Scope Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356
1605.3 88.13 165.74 .1233
7
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
HSPF:8.6
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type Subtype
Efficiency
Capacity Air Flow SHR Black
Ducts
1 Central Unit/ Split
SEER: 15 34.8 kBtu/hr
cfm 0.85 1
sys#1
9/15/2019 10:17 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
' 1 Electric
None
Garage
0.97
40 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System
Model # Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
/ — Supply —
— Return—
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT ON RLF
Heat Cool
1 Attic
6 275 ft'
Attic
65 ft'
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programabl[e
Cr[eiling Fans:
]Thermostaft:']Y
Heating [X] Jan Feb
Mar
Apr
I Me
May
f[[ ]]
Jun Jul
rl
r[[
Aug
()C)
[ ] Sep
[j ]]
L.l OOcctt
Nov
Dee
rD�,
Dec
Venting [[ 11 Jan [) Feb
l l
X Mar
[
Jun [ Jul
lXl
[ Aug
lX�
[)Sep
ll�X1J
[ ]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Coaling (WD) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
78
78
78 78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78 78
78
78
78 78
78
78
PM
78
78
78
78
78 78
78
78
78 78
78
78
Heating (WD) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft'
0 ft
0.3
BEDROOM
Default(8 lbs/sq.ft.
ft,
ft
0.3
WIC
Default(8 lbs/sq.ft.
ft'
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft'
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft,
ft
0.3
BATH
Default(8 Ibs/sq.ft.
ft,
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft'
ft
0.3
ENTRY
Default(8 lbslsq.ft.
ft'
ft
0.3
LAUNDRY
Default(8 lbs/s.ft.
ft'
ft
0.3
GREAT/DINING
9/15/2019 10:17 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE
Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY
City, Stale, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner: Jurisdiction:
w
Design Location: FL, Fort Pierce
c=.t
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
/soffit
The insulation in an dropped ceiling/soffit
y Pp 9
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind nining and wiring
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electricallphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire qnrinkler cover Mates and wnliq or ceqlqnos.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
9/15/2019 10:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX" = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1720
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.058
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.285
14. Heating system: Capacity
34.8
c) Area
7c.
155.4
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
0 Heat recovery unit HeatReC%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features. \ G
Builder Signature: C1 Date: \ D\ 1 ` 1
Address of New Home: WYNNE DEV. q �,e \-A 5 City/FL Zip: FT. PIERCE. FL
9/15/2019 10:18:09 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1