HomeMy WebLinkAboutGENERATOR PAPPERWORKINCLUDES: SCANNED
• True Power"' Electrical Technology BY
• Two Une LCD Multilingual Digital St. Lucie County
Evolution'" Controller (English/Spanish/ ST.LUCIE COUNTY
French/Portuguese) PLAN REVIEW
Standby Power Rating
Models G007036-1, G007037-1 (Aluminum - Bisque) - 16 kW 60 Hz
Model G007035-1 (Aluminum- Bisque) -16 kW 60 Hz
Models G007039-1, G007038-1 (Aluminum - Bisque) - 20 kW 60 Hz
Models G007043-2, G007042-2 (Aluminum - Bisque) - 22 kW 60 Hz
• Two Transfer Switch Options Available:
100 Amp, 16 Circuit Switch or
BLDG:
200 Amp Service Rated Smart Switch.
See Page 4 for Details.
DATE:
• Electronic Governor
ELE
• Standard WI -FP" Remote Monitoring
DA :
• System Status & Maintenance Interval LED Indicatompt.UMB--
• Sound Attenuated Enclosure DATE:
• Flexible Fuel Line Connector MECH:
DATE:
• .Direct -To -Dirt Composite Mounting Pad
• Natural Gas or LP Gas Operation
• 5 Year Limited Warranty
• Listed and Labeled by the Southwest Research Institute allowing
installation as close as 18" (457 mm) to a structure.*
*Must be located away from doors, windows, and fresh air
intakes and in accordance with local codes.
ht(os:llassets.swd.orgllibmry/DimctoryOlListedProductsl
Consuucuonindusfry/973_DoC 204_13204-01-01 RevB.pdf .
FEATURES
GUS EDOS %,UIL 1 I LV L
Note: CUL cedification only applies to unbundled units and units packaged with
limited cheoil switches. Units packaged with the Smart Switchare UL cedilied In
the USA only.
O
INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are atilm headof Geneoc'ssuccess in
O
SOUD-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION:
providing the most reliable generators possible. Geneem's G-Force engine lineup otters added
This stale -of -the -art power maximizing regulation system is standard on
peace of mind and reliability for when you need it the most The G-Farce series engines are pur-
pose built and designed to handle the rigors of extended nm times in high temperatures and
all Generae models. It provides optimized FAST RESPONSE to changing
extreme operating conditions.
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque -matching the surge loads to the engine. Digital
voltage regulation at ±1%.
O
TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave
O
SINGLE SOURCE SERVICE RESPONSE from Generacs extensive dealer
form produce less than 5%Total Harmonic Distortion for utility quality power. This allows
network provides parts and service know-how for the entire unit, from the
confident operation of sensitive electronic equipment and micro -chip based appliances,
engine to the smallest electronic component.
such as variable speed HVAC systems.
O
TEST CRITERIA:
O
GENERAC TRANSFER SWITCHES: Long life and reliability are
J PROTOTYPE TESTED J NEMAMG7-22EVALUATION
synonymous with GENERAC POWER SYSTEMS. One reason for this
confidence is that the GENERAC product line includes its own transfer
J SYSTEM TORSIONAL TESTED d MOTOR STARTING ABILITY
systems and controls for total system compatibility.
O
MOBILE LINK'" REMOTE MONITORING: FREE with every Guardian Series Home
standby generator. Ayou to monitor the status
u,llows
=
GENERAC
®" O N
world using a smadphdne, tablet, or PC. Easily access information such as the current
t—
PROMISE
'�-��
operating status and maintenance aleds. Connect your account to your authorized service
dealer for fast friendly and proactive service. With Mobile Unk, you are taken care Of before
the next power outage.
16/20/22 kW
GENERAC°
features and benefits
Engine
•
Generac G-Force design
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma maly
rings helps the engine run cooler, reducing oil consumption resulting in longer engine life.
•
"Spiny-lok" cast iron cylinder walls
Rigid construction and added durability provide long engine life.
•
Electronic ignition/spark advance
These features combine to assure smooth, quick starting every time.
•
Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine
life. Now featuring up to a 2 year/200 hour oil change interval.
•
Low oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
•
High temperature shutdown
Prevents damage due to overheating.
Generator
•
Revolving field
Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature
generator.
•
Skewed stator
Produces a smooth output waveform for compatibility with electronic equipment.
•
Displaced phase excitation
Maximizes motor starting capability.
•
Automatic voltage regulation
Regulates the output voltage to -0% prevents damaging voltage spikes.
•
UL2200listed
For your safety.
Transfer Switch (if applicable) —
• Fully automatic Transfers your vital electrical loads to the energized source of power.
• NEMA 3R Can be installed inside or outside for maximum flexibility.
• Remote mounting Mounts near your existing distribution panel for simple, low-cost installation.
Evolution'" Controls
• Auto/Manual/Off illuminated buttons
• Two-line LCD multilingual display
• Sealed, raised buttons
• Utility voltage sensing
• Generator voltage sensing
• Utility interrupt delay
• Engine warm-up
• Engine coal -down
• Programmable exercise
• Smart battery charger
• Main line circuit breaker
• Electronic governor
Unit
• SAE weather protective enclosure
• Enclosed critical grade muffler
• Small, compact, attractive
Selects the operating mode and provides easy, ata-glance status indication in any condition.
Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
Smooth, weather -resistant user interface for programming and operations.
Constantly monitors utility voltage, selpoints 65%dropout, 80%pick-up, of standard voltage.
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default selling of
5 seconds . by a qualified dealer.
Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
Allows engine to cool prior to shutdown, setpoinl approximately 1 minute.
Operates engine to prevent oil seal drying and damage between power outages by running the generator
for 5 minutes every other week Also offers a selectable setting for weekly or monthly operation providing
flexibility and potentially lower fuel costs to the owner.
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM -style batteries.
Protects generator from overload.
Maintains constant 60 Hz frequency.
Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding
winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine
maintenance items. Electrostatically applied textured epoxy paint for added durability.
Quiet, critical grade muffler is mounted inside the unit to prevent Injuries.
Makes for an easy, eye appealing installation, as close as 180 away from a building.
GENERAC
16/20/22 kW features and benefits
Installation System
• 1 it (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe.
• Direct -to -did composite mounting pad Complex lattice design prevents settling or sinking of the generator system.
• Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life.
Remote Monitoring
-• Ability to view generator status
• Ability to view generator Exercise/Run and Total Hours
• Ability to view generator maintenance information
• Monthly report with previous month's activity.
• Ability to view generator battery information
• Weather information
Monitor your generator via your smadphone, tablet, or computer at any time via the Mobile link application for
complete peace of mind
Review the generator's complete protection profile for exercise hours and total hours
Provides maintenance information for your specific model generator when scheduled maintenance is due
Detailed monthly reports provide historical generator information
Built in battery diagnostics displaying current stale of the battery
Provides detailed local ambient weather conditions for generator location
GENERAC°
16/20/22 kW
specifications
Generator
Model
G007035-1, G007036-1,
G007038-1, G007039-1
0007042-2, G007043.2
G007037-1 (16 kW)
(20 kW)
(22 MAI)
Baled Maxmum Contiauops Power (Npaury (LP) _-- - _ _ _ -_`
-
_ ; 16000 Walls _
_._.
20000 Walls. _.
_= 20000 Watts ' -
Haled Maximum Continuous Power Capacity(NG)
16,000Wafts-
18,00DWafts'
19,500 Walls'
240--
Rated MmdmumContinuous Lead Current-240 Volts (LPMG) F
66.7/66.7
83.3p5A
_ ^917/813
Tohl Hatmanic DistoNon - `.;
Less than 5%
'. Less etan5%
-.. .Less than 5%:.�''
Main Line CircuO Breaker
70 Amp
90 Amp
100Amp
Phase
_
Number of Bdtdr Poles u �V • ___ __
,.. �_ ,_—.._ 2
J...2
2
Aal'edAC Fe4uenry
_..
�':_'_._60Nz
_.- -. • > - '�
-- �50 Events 6ch ` -. -..
Cyclic cranking: 16 we on 7 rest (90 sec mmomum dumtwn)
_
"Star[etcannol mengage until 5se'c`a0eren9To has slopped w „ _.
' Standard
t -
Standard
_ _,;_
nd BaOer/ Condition Indication
Standard
Intl OnderValtage Proteillon_m-_, v
_ ---^� -
__„__ . _ e ,.._- Standard
—StandardW
curten[Protedion _�
-
'_ __
ryemNre Shutdown
Standard
_ _
nse Lass Shutdown 77.>,.,`.
StandaN,
- ._......�.�"__.__.._,_.:_.z._...
Standard
Standard
No nowNal
GENERAC°
16/20/22 kW switch options
Limited Circuits Switch Features
• 16 space, 24 circuit, breakers not included.
• Electrically operated, mechanically -held contacts for fast, positive
connections
• Rated for all classes of load,100% equipment rated, both inductive and
resistive.
• 2-pole, 250 VAC contactors.
• 30 millisecond transfer time.
• Dual coil design.
• Rated for both copper and aluminum conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMAfUL 3R aluminum outdoor enclosure allows for indoor or outdoor
mounting flexibility.
• Multi listed for use with 1° standard, tandem, GFCI andAFCI breakers from
Siemens, Murray, Eaton and Square D for the most flexible and cost effec-
tive instal(.
Dimensions
Height
Width
Depth
H1
H2
W1
W2
in
26.75
30.1
10.5
13.5
6.91
mm
679.4
764.3
266.7
343.0
175.4
Wire flanges
Conductor Lug
Neutral Lug
Ground Lug
110-#14
2/0-#14
2/0-#14
Service Rated Smart Switch Features
• Includes Digital Power Management Technology standard (DPM).
• Intelligently manages up to four air conditioner loads with no additional
hardware.
• Up to lour more large (240 VAC) loads can be managed when used in
conjunction with Smart Management Modules (SMMs).
• Electrically operated, mechanically -held contacts for fast, clean connections.
• Rated for all classes 0f load,100% equipment rated, both inductive and resis-
tive.
• 2-pole, 250 VAC contactors.
• Service equipment rated, dual coil design.
• Rated for both aluminum and copper conductors.
• Main contacts are silver plated or silver alloy to resist welding and slicking.
• NEMA(UL 311 aluminum outdo or enclosure allows for indoor or outdoor mount-
ing flexibility.
Dimensions
200 Amps 120/240, 10
Open Transition Service Rated
Hof
Id
Width
Depth
H7
H2
WI
W2
in
26.75
30.1
10.5
13.5
6.91
mm
679A
1 764.3
1 266.7
L 343.0
175.4
Model G007035-1(161W)
Current Rating (Amps)
100
_
U01ityVoltage Monitor(Fmd)'
-Pickup
80%
-Dropout
65%
Nrumto Dhhry__"___. .. ':.. _ ______
a_PProx lS sec._. •.
Exercises bl-weekly for 5 minules*t
Standard
_......_.____..__
StandaN
Total Circuits Available
24
.Tan,eTBreakv_(apabib0es
Circuit Breaker Protected
Available RMS Symmetrical
10.000
Fault current @ 250 Volts
`Function of Evolution Controller
Exercise can be set to weekly or monthly
Model G007037-1 (16 10)/G007039.1 (20 kW)/
G007043-2 (22 kW)
.Ne of Pales __
Cunem Rating (Amps)
'Voltage Hating NAC)_ -__ 0/240 7G,
-Pickup
80%
-Dropout
65%
'BeWm to Utility*
Exercises bi-weekly lor5 minutes•
Standard
�,ULLfsled
_._- Standard_. -_
fNEMANL
__V, ..... _.. -----
Enclosure Type
3111
iCircwt BreakerPrdlegdd
_
Lug Range
250 MCM-#6
16/20/22 kW
GENERAC
available accessories
Model Product Oescnptmn �.
The Wi-R enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Moo
I G007005-0 Wi•Fi LP Fuel Level Monitor doing the LP tanks fuel level is an important step in making sure your generator is ready to Run during an
i 1 unexpected powerfadure. Status alerts are available through a free application to notify when your LP tank
I i lisinneed ofarefill. _
;Every standby generator requires a battery to start the system. Generac offers the recommended 25R wel
G005819-0 ; 26R Wet Cell Battery — —
j cell battery for use with all air-cooled standby product (excluding PowerPact®).
i I The pad warmer rests under the battery. Recommended for use 9 the temperature regularly falls below OOF,
i G007101-0 j Battery Pad Wanner (Not necessary for use with AGM -style batteries).
iG007102-0
;Oil Wanner
oil warmer slips directly overthe oil filter. Recommended for use if the temperature regularly falls below O*F.'
fThebreatherwarmerisforuseinexhWith
jG007103-1
;-Breather Warmer
i
only in climates where heavy icing occurs.
G005621-D
�Auxiliary Transfer 8wttch�;The
auxiliary hansferswhchcontact lot allows the transfer switch iolock out asingle large electdcalloadl
Contact Kit
you may not need. Not compatible with 50 amp pre -wired switches. i
's
'
Fascia Base Wrap Kit
The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a '
G007027-0 -Bisque
(Standard an 22 kW)
sleek, contoured appearance as well as offering protection from rodents and insects by covering the Idling I
holes located in the base. I
—�
j
If the is or damaged, it is Important to touch-up the to protect from
G005703-0 - Bisque
;Paint Kit
generator enclosure scratched paint
ifofurecorrosion.Thepaintkitincludesthenecessarypainttopropertymaintainortouch-up a generator;
i
;enclosure.
G006485-0 1 Genemc's scheduled maintenance kits provide all the hardware necessary to perform complete routine
Scheduled Maintenance Kit !maintenance on a Generac automatic standby generator.
G006873-0 i 'Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its
i Smart Management Module power management capabilities. It provides additional power management flexibility, notfound in any othe
i(SDAmps) power management system.
dimensions & UPCs
Dimensions shoxn are approu mate Refer to inthlWion manual fur read dimensions. 00 NOT USE RUE DIMENSIONS FOR INSFALAnON PURPOSES.
LE SIDEvlEw
P Nrrvum
Model
UPC
G007035-1
696471074161
G007036-1
696471074154
G007037-1
696471074178
G007038-1
696471074185
G007039-1
696471074192
G007042-2
696471074208
G007043-2
696471074215
GENE RAC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
02018 Generac PovrerSystems,Inc. An rights reserved. All specdcagons are subject to change without notice. Part No. 10000000194-G 03/76/18