HomeMy WebLinkAboutPROPANE PAPPERWORK,.,c,. r--i �. .. 1. Designed to reduce first stage pressure of 5 to 20 PSIG down to bumer pressure, normally 11- w.c. Ideal for medium commercial Installations, multiple cylinder installations and normal domestic loads. Large vent helps prevent blockage and has i" F.NPT for vent piping. • With 15 PSIG inlet pressure, regulator is designed to not pass more than 2 PSIG with the seat disc removed. Incorporates integral relief valves. Replaceable valve orifice and valve seat disc. Straight line valve closure reduces wear on seat disc. Unique bonnet vent profile minimizes vent freeze over when properly installed. Large molded diaphragm is extra sensitive to pressure changes. Built in pressure tap has plugged 1/8" RNPT outlet Plug can be removed with a 3/16" hex alien wrench. Select brown finish. Mounts directly to house line piping. Eliminates need for union joints, elbows, and mounting brackets. Quick and easy to install. • Backmount design Maximum flow based on 10 PSIG Wei and 9• w.o. delivery pressure. Body.............................................................................. Die Cast Zinc Bonnet........................................................................... Die Cast Zinc NozzleOrifice ............................................................................ Brass Spring Steel Valve Seat Disc ...................................................... Resilient Rubber Diaphragm ........................... Integrated Fabric and Synthetic Rubber. E m1� 1 i ol( ot• BTUTIC swot: LV4403135erks -11--__iiiii•_--- ����ir��i�. -. a •r .�� .. ... . r t SCANNED BY St. Lucie County p 1c too Bego Or. P.O. Box 247 Gon. NC 272" USA x nsgopmducts:mm Phore (336) "9-M7 Fax (336) a 594 evEGQ. Application Materials Ideal for use as a first stage regulator on any domestic size ASME or DOT container in propane gas installations requiring up to 1,500,000 BTU's per hour. The regulator is factory set to reduce container pressure to an intermediate pressure of approximately 10 PSIG. Features Compact design can be connected to a service valve using either a POL adapter or a RegO product pigtail. Large threadedYd' FNPT bonnet vent can easily be piped -away underground installations without the need of glue kits or extra adapters. • Non Adjustable • Large flow orifice resists freeze ups due to water concentration in LPG vapor. • Design provides for good flow regulation at both high and low container pressures. • Built in relief valve and travel stop comply with NFPA 58 over pressure requirements. • Incorporates W PNPT downstream pressure tap for an easy inline check of the regulator'sdefivery pressure. • Molded diaphragm provides an o-ring type seal between the body and bonnet. • Body and bonnet are assembled in the USA using the unique, patented RegUlok seal system. Fully painted in brilliant red for complete corrosion protection. Mounting bracket available as an accessory. part number 2302-31 Ordering Information Body........................ .... ._.......... .......... .... ........ _-----.. .................. Zinc Bonnet.................... --.................,........................... .. Spring ..................... ._............. ..................... .......... ................. . Steel Seat Disc ..................... .... ..._.................................. Resilient Rubber Diaphragm..... I.... ................. Integrated Fabric and Synthetic Rubber ONE 00 OMEN �MM gry�p, ammo smm¢ WOO t,mopm LueP¢¢ FLOW vaarANE ®LV3da3TR I I vver vmiat 1,500,000 /°FNPT %°FNPT Yl 10 PSIG 9.00 r LV3403TRV9 2a%1 m m N 9 MazMumgmv Eased an lNelpressure 20 Ps10 higherlhan Ne regWatorseeNg antl de0very pmssurp 2a%I Ihs ih egNam alLag dtl E ryp resS oep A14 10E Rego Or. P.O. B¢t 247 FJon, NC 272" USA vnvv.regopmducrs.com Ph,n¢ (136)1A9-7r6r FaX (326) 44M594 5W_11=7. wutmsnn Qui --,,,Steel Corporation AG/UG Plch"L-e Tanks �,�t L 1450 w9. AND -U? APPIRMIMATE ABOVEGROUND/UNDEGROUND'(AG/UG) VESSEL DIMENSIONS AND SPECIFICATIONS WATER CAPACITY DIAMETER (OD). HEAD TYPE OVERALL LENGTH OVERALL HEIGHT . LEG* WIDTH LEG** SPACING WEIGHT (Ibs.) **QUANTITY FULLLOAD. PEasTACK *120 wg. 24" Ellip. 5'-8" 3' 1'-1 1/2" 2'-101/2"260 or 3�11" 108 196 161 12 *250 wg. Lh- 30" Hemi. 7'40" 3'-8" 1'-5" 4-41" 480 54 9 '*320 wg. 30" Hemi. 9'-7" 3'-8" V-5" 5' 620 45 9 500 wg. 371/2" Hemi. 10' 4'-2" 1'4' 1 950 37 1 30* 8 6 1000wg. 41" Hemi. 16' 4'-5" 1'-8" 10'1" 1,800 17115 1 6 5 1450 wg. 461/2" Ellip. IT-04'-11" V-9" 117' 2,650 12 4 1990 wg. 461/2" Ellip. 23'-11" 4'-11" V-9" 15' 3,520 8 14 Dimensions and specifications shown are approximate. Individual vessels may vary. •Leg spacing +/-2". Leg widths and spacing may vary based on mfg. location. Check with your salespuso n for details. 120, Z50, 320 we. standard tanks - no holes in legs (one center hole on request). 500 and 1000 wg. standard tanks - 2 holes 16" on ceder. 1450 wg. and up as shown above. ..Full load and stack quantities vary by shipping location. Check with your salesperson for details. General Specifications Conforms to the latest edition of ASME Rules for Construction of PressureVessels, Section VIII, Division 1. Complies with NFPA 58. Rated at 250 psig from -20° F to 125' F. All vessels registered with National Board. Two service options available: Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite AG/UG dome. Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid applied epoxy primer coat followed by urethane topcoat, supplied with steel AG/UG dome. - All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel. Updated June 30, 2015 V. CABLE W/ CLAMPS TO (PULLED ANCHOR STRAP (2) LAYERS OF FELT BETWEEN STRAP AND TIGHT) R (PU LAMPS 0/� UNDERGROUND .TANK HOLD DOWN DETAIL GENERAL NOTES: 1. HEUCAL ANCHORS SHALL HAVE AN ALLOWABLE PULL—OUT CAPACITY AS SHOWN BELOW. ANCHORS SHALL BE INSTALLED PER ANCHOR AAkNI)Fr1WRERJO ACHIEVE STATED LOAD CAPACITY., CAPACITY VARIES WITH SOIL TYPE VERIFY ANCHOR CAPACITY WITH SOIL POORTERED — 250650j. 29 GAL T)WK. a ."..CHECK (00: LARRGROIUND-OTIUTIES PRIOR TO ANCHOR INSTALLATION -3.- sLOCATION OF TANK RELATIW40 ADJACENT STRUCTURES AND FEATURES ARE DEPENDENT UPON LOCAL CODES AND IS THE rRE'SPONSIBILTTY OF OTHERS. < 4':. "THE _TANK .AS SHOWN HAS. BEEN DESIGNED TO PREVENT FLOTATION, COLLAPSE, OR LATERAL MOVEMENT DURING THE BASE ;ELOOb VENT _ 0 COPYRIGHT 2016 — FARLEY ENGINEERING, LLC PA DAT ' AMERIGAS Consultlng Engineer 440111 — CA28108 ^^co 0 ih O O O O O O O G1A11 QUI Q �]U� N J In tt.--] O �O W J C�tJ� �'�•• � oa oo,000 000ao ulo�n�v, otn000 oao� W W A p F 4 �R IL T OI �1✓- b}�O1 �aN T�PNOI ..• m LJ FSj W N O. W O A W ,ll1 W J �] � �-• F- i T J O V W r UI W OI UI ��1 � a a tb w'e IV m y y p. W N W •F W �G V� W W .p O� i=• W 1•+ N OI �-• `a V \J V Ol lr' {a. U] �.] � U] J W m tJ'.11 .�. O'T � � p H I.I s �• �.] I y of/Ils'A • J �O u] Aul rn !.-I b O�a 4i .i o�l� b LJ lwilo N �s wwoUol T �l ?'•�b �••. m w 1 •. ] a 4+ 4 O `-' O� O J O W C1�. � O N J A t h N A� g � p• �� N W wiQ+ a ll] J y U1 IJ 0 O IJ� q l+ ST � O+ V�� V fA 1"/ J 00 F+ O �• i o. N �-'f-• W W Q A•� o o.ee�i J a•a .p .Ir �-• ..+a ao+ a �m- lJ 1 p I 1✓ W w w A I.{� A A U l U] I a O t O l u wlrnwrn N,�ls�"�s w-A-II�oGi �✓ W U] F+ r F+ W b U r+ Vl a A IO Q m o]] O ti. UI EpoZO W l�. W,Wp Nd Gp i laei IJ� N l�]or0 6.P O 1 y NN U] Wvr O] arbN �l.a iN��.r'P- OOq� yp� � t.• �• uQ OQ W r-w JbNU� N � O O �a Lei BOARD OF COUNTY COMMISSIONERS PLANNING & DEVELOPMENT SERVICES DEPARTMENT Building and Code Regulation Division GAS PIPING SCHEMATIC TANK SIZE:Qv GALS. APPLICANCE — TYPE/SIZE Al�0/Y)L - A2 A3 A4 A5 A6 PIPING LENGTH & SIZE L1 FT. —,5UtiNCH DIA. L2 FT. INCH DIA. L3 FT. INCH DIA. L4 FT. INCH DIA. L5 FT INCH DIA. L6 FT. L7 FT. L8 FT. L9 FT. L10 FT L11 FT L12 FT Revised 7122114 INCH DIA. INCH DIA. INCH DIA. INCH DIA. INCH DIA. INCH DIA. INCH DIA. Parmiffln® ®,e� 9 dent Luigi, rgdN BTU BTU BTU BTU BTU (PIPE SIZE WAS TAKEN FROM THE 2014 FBCFUEL GAS CODE - TABLE 402 (___J) Websile: www.stlucieco.aov 2300 Virginia Avenue - Fort Pierce, FL 34982-5652 Phone (772) 462-1553 FAX (772) 462-1578