HomeMy WebLinkAboutMISC EMAILPacifico Engineering PC 700 Lakeland Ave, Suite 2B Bohemia, NY 11716 October 16, 2019 St. Lucie County Building and Code Regulation Division Engineering Consulting Ph:631-988-0000 C~WA �®■D sclar@pacificoengineering.com ST.LUCIE COUNTY PLAN REVIEW 2300 Virginia Avenue KtC-t1VtU BLDG: Fort Pierce, FL 34982 DOCT 2 2 ZJ19 EZATE:�, - / �/ Subject: Solar Energy Installation for G Rey Manuel Lugo Vega Jr ST. Lucie County, Permitting DATE:/ 5846 Sunberry Circle PLUMB: Fort Pierce, FL 34951 DATE: MECH: I have reviewed the roofing structure at the subject address. The structure can support 8yVI%dditio— na weight of the roof mounted system. The units are to be installed in accordance with the manufacturer's installation mstrudbns-+have determined that the installation will meet the requirements of the 2017 Florida Building Code - Residential, Sixth Edition, and ASCE7-10 when installed in accordance with the manufacturer's instructions. SCANNED Roof Section A BY Mean roof height 10.0 ft St. Lucie Count, Pitch 18 degrees Roof rafter 2x4 Truss Rafter spacing 24inch on center Reflected roof rafter span 6.1 it Rafter span max allowable 7.5 ft The climactic and load information is below. CLIMACTIC AND Wind Live Load, Point GEOGRAPHIC DESIGN Exposure Live Load, Speed, 3 Pnet per pullout Fastener Type CRITERIA Category Pg, psf sec gust, ASCE 7, load, lb mph psf Roof Section A B 20 170 57 618 SS 5116" dia lag bolt, 4" length, 2 per Weight Distribution array dead load 3.5 psf load per attachment 38.0lb Subject roof has one layer of shingles. Panels mounted flush to roof no higher than 6 inches above roof surface. Ralph Pacifico, PE Professional Engineer ��-PH•PAC/,c CE/y •.. �0 F •O' .87297 o STATE ' �, OF